Pulsar SandAlert Lite Second Edition Operating Handbook

File Specifications

Brand: Pulsar
Category: Microphone
Model: SandAlert Lite Second Edition (Operating Handbook), prmtoEBeiF3E6
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 26 pages

Download PDF

Download Pulsar SandAlert Lite Second Edition Manual (26 pages)

Read Online:

Read the Pulsar SandAlert Lite Second Edition Operating Handbook online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

SandAlert Lite 2nd Edition

Page 17 Enter the flow rate Enter the average particle size, and the system then calculates the calibration factor. This figure can be modified with choice 3 Edit Factor. Be careful changing the factor as it can change the weight figure dramatically. It is best to stick with Auto Calibrate unless a known weight of sand is being produced and the system is calibrated at that time. Edit Factor Screen, it is not recommended to change the calibration factor unless you are sure it is necessary and understand the consequences. 4. and 5. File Handling and Event Log are not f ...

SandAlert Lite 2nd Edition

Page 7 Threshold Threshold c - High Flow, No Sand d - High Flow, With Sand The SandAlert Lite unit eliminates the flow noise by placing a threshold automatically just above the flow related noise signal, and if the signal goes higher than this then it is due to solid impacts, which can be seen in b and d as short duration, high energy spikes, as compared with the flow related noise that is longer duration, and of lower energy. The threshold is visibly higher in d, due to the higher level of flow related noise. There is also an option with the SandAlert Lite to utilis ...

SandAlert Lite 2nd Edition

Page 9 Where vibratory conditions exist it is recommended that a thread locking adhesive is used. Also it is important to ensure that the free end of the chain is cannot fret against the clamp or the pipe, by tying it up with cable ties. The PULSARguard 2001 is fitted using stainless steel banding (11mm wide), you can either use a re-usable “jubillee” clip type toothed band, or by a plain band with crimpable clips. All the above points regarding position and surface preparation above apply. Always ensure that the pipe is cleaned to bare metal and that the silico ...

SandAlert Lite 2nd Edition

Page 4 The sensor housing is rated at IP68 giving protection against temporary immersion to a depth of 3 metres. The sensors are powered from a power supply via a galvanically isolated safety barriers, in the SandAlert Lite unit. The sensors are attached to the outside of the pipe, on or just after a bend, by means of a universal pipe diameter (3" to 8") stainless steel sensor/pipe clamps. The sensor is connected to the SandAlert Lite via in-line connectors and a 100 metre extension cable, although it can be extended to 1000 metres if required. Note: The Pulsarguard ...

SandAlert Lite 2nd Edition

Page 23 7.3 SandAlert Lite contol unit: Construction Epoxy coated steel case with hinged lid Computer Hardware IBM compatible computer running the Pulsar Sand Alert Software loaded on an internal Hard drive, RS232 communications port, A/D with 100kHz sampling rate 12 bit resolution. Power Supply Mains 85 to 240 V at 50 to 60 Hz. The internal power supplies provide dc power to the computer hardware and the sensor. Weight 10 kg Dimensions Overall height 150mm Overall depth 300mm Overall length 400mm Revision Record Date Issue Revison Issue 2 9/9/04 Add Threshold o ...

SandAlert Lite 2nd Edition

Page 12 6 SandAlert Lite user interface This section describes the set-up of the Navigating the software menus: Title screen, this does not stay visible for long as the default operation of the unit is to go straight to monitoring after power-up. This is the monitoring screen, the system will automatically go to this screen on power-up. 6.1 To get to the main menu press ESC. ...

SandAlert Lite 2nd Edition

Page 15 2. Saver Time: This is the time before the screen saver is activated. 3. Deletion Time: Not appplicable to SandAlert Lite. 4. Display Units: Choose between Sand Impact Rate (SIR) and a % of sand impact rate, based on View max set up for the wellhead earlier. 5. Rate Unit: Sets the units to be displayed when you have calibrated the system to display weight ESC. Takes you back to the Set-up menu. 6.2.5. Allows the setting of the time and date: You have three choices: 1. Change Date: See below, Enter the correct date. 2. Change Time: Enter the correct time 3. ...

Pulsar SandAlert Lite Second Edition user guide recommended for: Microflex MX396, Wireless Mini Microphone, A-1 S02, LS-208, freedom back.

⚠️ Download Safety

The Microphone Operating handbook (26 pages) is completely safe to download (last scan date: 09/03/2026).

Related PDF Instructions for Pulsar SandAlert Lite Second Edition:

Microphone Equipment: Frequently Requested

Have some Questions about Pulsar SandAlert Lite Second Edition Device?

Get valuable and actionable advices from other Pulsar SandAlert Lite Second Edition device users. Describe your problem or question, regarding the using of SandAlert Lite Second Edition, in as much detail as possible, and other users will be able to answer you.