Siemens SISTORE AX9 Quick Reference Manual
Read Online
Read the Siemens SISTORE AX9 Quick Reference Manual online using the built-in PDF viewer.
Text of the manual
Data and design subject to change without notice. / Supply subject to availability.
© 2004 Copyright by
Siemens Building Technologies AG
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
This manual covers the 9- and 16-channel digital video recorders. The DVRs are identical except for the number of cameras and alarms that
can be connected and the number of cameras that can be displayed. For simplicity, the illustrations and descriptions in this quick reference
refer to the 16-camera model.
Contents
Preface.............................................................................................................3
FCC statement of conformity ..............................................................................3
CE declaration of conformity...............................................................................3
1
Installation........................................................................................3
2
Operation..........................................................................................4
2.1
Turning on the Power .........................................................................4
2.2
Playback Commands ..........................................................................5
2.3
Front Panel Buttons and LEDs ............................................................6
2.4
System Setup.....................................................................................6
Siemens Building Technologies
QSG_SISTORE_AX9_AX16_en.doc
Fire & Security Products
01.2004
Preface
FCC statement of conformity
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
CE declaration of conformity
The device supplied with this Instruction Manual meets the requirements of the
European Directive 89/336/EWG (electromagnetic compatibility). Compliance with
this EC directive has been proven by testing according to the standards
EN 50130-4 (EN 61000-2, -3, -4, -5, -6 and -11) for noise immunity and EN 55022
Class A for emitted interference.
1
Installation
The SISTORE AX9/AX16 is designed to work a variety of other equipment. The
basic system will consist of a video camera and system monitor.
Refer to the User’s Manual CD (see directory:
SISTORE AX\\Documentation\\SISTORE AX9 AX16_EN.pdf)
for details of installing each type of equipment.
Fig. 1
SISTORE AX16 Rear Panel
Step 1:
Video In: Connect cameras (up to 9/16) to camera BNC inputs. If looping is
required, connect camera out to second source (second BNC).
Step 2:
Video Out and SVHS Out: Connect a monitor to a composite video output for multi-
screen display and playback. Connect a monitor to SVHS output if needed.
Step 3:
Power Connector: Apply power to the unit. Please note that the AX4 uses a
different power supply than that used with the AX9 and AX16 models!
Siemens Building Technologies
QSG_SISTORE_AX9_AX16_en.doc
Fire & Security Products
01.2004
2
Operation
2.1
Turning on the Power
The SISTORE AX9/AX16 is operational in approximately 60 seconds after the
power cable is connected to the system. The SISTORE AX9/AX16 may be
powered down by selecting the System Shutdown menu from the Quick Setup or
Normal Setup screen. When shutting down the DVR, you need to confirm that you
want to shut down the unit, and you will be asked for an administrator password.
No on/off switch is provided.
Fig. 2
SISTORE AX16 Front Panel
Display Modes
Press the desired camera number button to view the desired camera image, and
press the DISPLAY button repeatedly to toggle between different display formats:
full, 4 x 4, 3 x 3, 2 x 2 and PIP.
Recording
Once you have installed the system following the instructions described in the
User’s Manual, it is ready to record. There is no recording button on the front panel
to initiate recording video. The SISTORE AX9/16 will start recording video
according to the schedule configured by the user and from external and internal
events such as alarm input or motion detection events.
Siemens Building Technologies
QSG_SISTORE_AX9_AX16_en.doc
Fire & Security Products
01.2004
2.2
Playback Commands
Camera Buttons (1 to 16)
Pressing a camera button will display that camera full screen.
Display Button
Pressing the Display button during playback will cycle the display through the
different screen layouts. The display modes are: full, 4 x 4 and 3 x 3, and 2 x 2 (4 x
4 format is not available for the SISTORE AX9). You cannot change the display
format while playing back video. Pause the video first, then change the format.
RW (Rewind) Button
Pressing the RW button plays video backward at high speed. Pressing the button
again toggles the playback speed from
,
and
. The screen displays
,
and
respectively. Entering Fast Backward Playback mode from
Live Monitoring mode can be password protected.
PREV (Previous) Button
The PREV button only functions when playback video has been paused. Pressing
the PREV button plays video backward image-by-image.
Stop Button
Pressing the Stop button during Playback mode returns the DVR to the Live
Monitoring mode.
Next Button
The Next button only functions when playback video has been paused. Pressing
the Next button plays video forward image-by-image.
FF (Fast Forward) Button
Pressing the FF button plays video forward at high speed. Pressing the button
again toggles the playback speed from
,
and
. The screen displays
,
and
respectively. Entering Fast Playback mode from Live
Monitoring mode can be password protected.
Siemens Building Technologies
QSG_SISTORE_AX9_AX16_en.doc
Fire & Security Products
01.2004
2.3
Front Panel Buttons and LEDs
Camera
(1-9/16)
Pressing the individual camera buttons will cause the selected camera to display full
screen. They are also used to enter passwords.
Sequence
When in the live mode, pressing the Sequence button displays another full live channel
sequentially.
Display
Pressing the Display button toggles between different display formats.
PTZ
Pressing the PTZ button opens a Pan/Tilt/Zoom screen which allows you to control
properly configured cameras.
Freeze
Pressing the Freeze button freezes the current live screen.
Alarm
Pressing the Alarm button resets the DVR’s outputs including the internal buzzer during
an alarm, or displays the event log when you are in the live monitoring mode unless
there is an active alarm.
Search
Pressing the Search button displays the Search menu.
Menu
Pressing the Menu button enters the Quick Setup screen.
Enter
Pressing the Enter button selects a highlighted item or completes an entry that you have
made.
Arrow
These buttons are used to navigate through menus and Graphic User Interface (GUI).
Duplex
The Duplex LED is lit when the DVR is operating in the Duplex mode.
Network
The Network LED is lit when the unit is networked either via Ethernet or modem.
Backup
The Backup LED is lit when data is being backed up using the USB port.
REC
Press the REC button to set the DVR so that it is ready to record video
2.4
System Setup
The front panel buttons are used to enter system commands and for programming.
Press MENU button on the front panel and enter the password (default: 4321) by
pressing the appropriate combination of Camera number buttons and then the
Enter button. Refer to User’s Manual for the setup instructions in detail. The
documentation is located on the CD or in the application folder on the PC hard disk
(C:\SISTORE AX\…).
Quick Setup Menu
Normal Setup Menu
Siemens Building Technologies
QSG_SISTORE_AX9_AX16_en.doc
Fire & Security Products
01.2004
Issued by SGS
Fire & Security Products
D-76187 Karlsruhe
www.sbt.siemens.com/FSP
© 2004 Copyright by
Siemens Building Technologies AG
Data and design subject to change without notice.
Supply subject to availability.
Printed in the Federal Republic of Germany
on environment-friendly chlorine-free paper.
Document no.
A24205-A336-B604
CA70-0080
Edition
01.2004