■ Safety Precautions
Before using this product, please read this "Safety Precautions" for proper operation.
WARNING
The WARNING symbol indicates the possibility of death or serious
injury if the product is not used properly.
CAUTION
The CAUTION symbol indicates the possibility of minor to
moderate personal injury or product damage if the product is not
used properly.
NOTICE
The NOTICE symbol indicates cautions or restrictions when using
the product. Please read all notes to avoid errors in operation.
NOTE
The reference symbol indicates additional information about the
controls or related functions. Reading these is recommended.
The arrow indicates reference pages.
WARNING
● Please refrain from opening the product packaging with wet hands or in a
dusty environment as this may cause damage to the product.
● Keep the materials used in this product out of the reach of children to
prevent accidental ingestion and misuse.
CAUTION
● To avoid damage from static electricity, remove the static electricity from
your body by touching metals located nearby (e.g. door knob, aluminum
sash) before touching the radio transmitting module.
● Do not under any circumstances remodel or disassemble this product for
modification or part replacement purposes.
■ Terms and Trademarks
Godox
® is the registered trademark of Godox Photo Equipment Co. Ltd.
© 2020 SEKONIC CORPORATION All Rights Reserved.
● Do not use the meter in Cord Flash Mode at altitudes above 2,000m (6,561 feet).
● Be sure not to drop the product or subject it to sudden impacts, as the product will be
damaged.
● Do not store the product in areas of high temperature of high humidity, as the product will
be damaged.
● Be careful not to transport the product from cold to warm moist conditions as
condensation will form on the product and may damage it.
● If the product is left in direct sunlight, a vehicle, or near a heater, the unit's temperature
will rise and may result in damage. Please be careful when using the product in these
types of locations.
● If the product is left where corrosive gases may be generated, the gases may affect the
product and may result in damage. Please be careful when using the product in these
types of locations.
● Reproduction of all or any part of this document without permission is strictly forbidden.
● The contents of this manual may be subject to change for the product's specification
modifications and other reasons without prior notice.
● The screens in this operating manual may differ from the actual displays of the product
you are using. (Colors, letters, etc.)
NOTE
In case of disposing the product, follow the rules of disposal in your area.
■ List of Applicable Model
This transmitter is an accessory dedicated to the following model (light meter).
Model
Transmitter Model
Manufacturer/Frequency
L-858D Series Serial No.
RT-GX
Godox : 2.4GHz
JY10-XXXXXX
(For Japan)
JY11-XXXXXX
(For Europe and Canada)
JY1L-XXXXXX
(For US)
JY1G-XXXXXX
(For China)
● Check if L-858D firmware is the latest version by using "Update Settings" function of
Data Transfer Software connected with L-858D.
● Download the Data Transfer Software from www.sekonic.com, and install it on your
computer.
URL: https://www.sekonic.com/support/downloads/dtssoftwareformacandwindows.aspx
To use this software, connect your computer to the L-858D using a USB cable (micro-B
type, available commercially).
■ Intended Use
This product can be used in the following situations.
● Radio wave-based flash light triggering or output power control
● Radio wave-based modeling lamp ON/OFF or output power control
■ Intended Users
The intended users of this product are those who are engaged in shooting or related
businesses, such as photographers, who use the flash units.
■ Disclaimer
The Company shall not be liable for any direct or indirect damage resulting from the
failure of this product or its use.
■ Features of the RT-GX
To use the radio triggering mode of the L-858D after the transmitter is installed, the flash
unit must be equipped with a radio function supported by a specified manufacturer, or a
receiver supporting the radio function must be connected to the flash unit.
Using the radio triggering mode, firing a flash or adjusting the output power by yourself
can be easily accomplished remotely.
● Take measurements by placing the product at the subject's position with the light
receptor (retracted lumisphere) facing toward the light sources of main light and fill
light directly. Adjust the measured values for the desired lighting ratio.
● Turn on all light sources to measure the final exposure, and point the lumisphere
(extended lumisphere) at the camera from the position of subject (P16, P31,
P39)
Note that this transmitter of RT-GX only supports the Godox
® radio system.
Manufacturer
Radio CH/Group
Function
Godox
Channel : 1 to 32
Group : A to F, 0 to 9, ALL
Wireless ID : OFF, 1 to 99
Flash light triggering and output power
control, modeling lamp ON/OFF and output
power control
■ Restrictions
There are some cautions and restrictions regarding the use of this product.
Please read and understand the following before using the product.
Godox : Group : A to F, 0 to 9
Light meter (with the
transmitter installed)
Light source (with a
receiver built-in/installed)
Camera
Group A
Group A
Group B
Group B
Subject
Figure 2
Subject
Figure 1
● The operation of this product may change without prior notice due to specification
changes or other reasons. Therefore, the contents of this operating manual may differ
from actual operation of the product.
URL: https://www.sekonic.com/support/downloads
● The safety-related precautions such as "Safety Guide and Maintenance" and "Safety
Precautions" conform to the legal and industry standards that were applicable at the time
this operating manual was created. Therefore, this manual may not contain the latest
information. If you are using the previous operating manual, please download and refer
to the latest operating manual.
● Before using this product, please read this "Safety Precautions" for proper operation.
● The product may contain printing materials such as cautions related to safety and/or
printing errors as a supplement to the operating manual.
● The contents of this operating manual may be reproduced for non-commercial purposes
and for personal use only. However, the reproduced material must contain the copyright
notice of our company.
● The screens in this operating manual may differ from the actual displays of the product
you are using. (Colors, letters, etc.)
■ Accompanying Accessories
The following items are included with the Transmitter RT-GX. Please be sure to check
that all noted items are included.
If any items are missing, please contact the distributor or the reseller you purchased the
transmitter from.
Transmitter Godox
Startup Guide
Safety Precaution
Safety Precaution
For Proper Operation
Before using this product, please read this "Safety Precautions" for
proper operation.
WARNING
The WARNING symbol indicates the
possibility of death or serious injury if the
product is not used properly.
CAUTION
The CAUTION symbol indicates the
possibility of minor to moderate personal
injury or product damage if the product is
not used properly.
NOTICE
The NOTICE symbol indicates cautions
or restrictions when using the product.
Please read all notes to avoid errors in
operation.
General Safety Information
• Read the Operating Manual before use.
• Keep the Operating Manual on hand for reference at any
time.
• Stop using this product when there are any abnormalities.
• The modification or disassembly of this product is prohibited.
• Do not attempt to repair this product by yourself.
• This product is intended only for persons with expert
knowledge.
• Monitor children so that they do not touch this product.
• Use this product in a usage environment described in the
Operating Manual.
• This product is not waterproof.
WARNING
There is a danger of electrical shock when using high
voltage strobes.
Avoid contacting the terminals.
This product emits electromagnetic waves.
Do not bring this product close to persons with
pacemakers.
Do not use this product in an explosive atmosphere.
Use of devices emitting electromagnetic waves is
prohibited in hospitals.
CAUTION
• Check the material of the neck strap to see if there is any
risk of allergy.
• Be careful of sudden emission of lights from strobes.
NOTICE
• Do not leave this product on car dashboards in hot weather.
This may damage the product.
• Remove the batteries when this product is not in use for a
long period of time.
• When the desired performance is not achieved, stop using
this product and contact the service center.
Information for Users on Collection and
Disposal of Old Equipment
To protect environment, do not through this device
and batteries away with the normal household waste
at the end of those life, but bring them in at an
official collection point of your country for recycling.
English
English
The steps for installing the transmitter module and meter setup are common
for RT-20PW/RT-3PW (PocketWizard
®), RT-BR (broncolor
®), RT-EL/PX
(Elinchrom
®, Phottix
®) and RT-GX (Godox
®) transmitters.
Before installing the transmitter, please read the operating manuals for
the meter and transmitter as well as the safety precautions so that you will
fully understand the features and operation of this product. Then keep the
manuals and this Startup Guide in a safe place for future use.
Displays in this start up guide is for explanation purpose. Content to be
displayed differs depending on which transmitter is installed.
1. Downloading Manuals
Please visit www.sekonic.com to download the latest
version of meter and transmitter operating manual.
Use the URL below for direct access.
URL : https://www.sekonic.com/support/downloads
2. Installing the Transmitter
1) Turn OFF the meter.
2) Unlatch and remove the Battery
cover.
3) Remove the Transmitter connector
cover.
4) Align the connector pins with those
of the transmitter module and insert the Transmitter.
* Be sure to reattach the connector cover if the Transmitter is removed.
5) Insert the Battery cover tabs (three) into the receiving holes in the
meter body, press the cover down and latch it closed.
3. Setting Radio System Preference
(for RT-20PW, RT-3PW and RT-EL/PX only)
Use the Custom Setting in Menu to set the
Radio System Preference for the flash system
in use.
RT-20PW/RT-3PW: ControlTL, Standard or
both
RT-EL/PX: Elinchrom Normal/Speed mode or
Phottix Strato II
4. Selecting Measuring Mode
Touch the icon to enter the Measuring Mode
Selection screen.
① Radio Triggering Flash Mode
Detects flash brightness after Measuring button is
pressed to send radio transmitted signal to radio
receiver connected to flash. Displays F-stop value.
② Radio Triggering Multi Flash Mode
Detects and accumulates flash brightness after
Measuring button is pressed to send radio
transmitted signal to radio receiver connected to
flash. Displays F-stop value.
③ HSS Flash Radio Triggering Mode (for RT-GX only)
Detects flash brightness after Measuring Button is
pressed to send radio transmitted signal to radio
receiver connected to flash. Displays F-stop value.
④ Flash Duration Analysis Radio Triggering Mode
Detects flash brightness after Measuring button is
pressed to send radio transmitted signal to radio
receiver connected to flash. Displays F-stop value
and flash duration time.
5. Setting Channel (Studio) and Zone/Group (Lamp)
Use Tool Box screen to set the meter (transmitter)
to the same channel (studio) and zone(s) / group(s)
(lamp) as the receivers.
In addition, set the wireless ID when using RT-GX.
* For details, see the operating manuals for
transmitter.
Transmitter
RT-20PW (344MHz), RT-3PW (433MHz)
RT-BR (2.4GHz), RT-EL/PX (2.4GHz)
RT-GX (2.4GHz)
Startup Guide
Example of RT-GX
[Measuring screen]
[Measuring Mode
Selection screen]
[Tool Box screen]
RT-20PW
RT-3PW
RT-EL/PX
[Radio System Preference screen]
①
②
③
④
1. Before Use ........................................................................................................................................................................ 1
1-1
Installing the Transmitter .......................................................................................................................... 1
2. About Godox Radio System ......................................................................................................................... 3
2-1
Overview........................................................................................................................................................... 3
2-2
Setting the Radio CH/Group ................................................................................................................... 4
2-2-1
Setting on the Tool Box Screen ............................................................................................................. 4
2-2-2
Setting in Measuring Screen (Group setting only) ....................................................................... 8
2-3
Setting the Wireless ID ............................................................................................................................11
2-4
Measuring ......................................................................................................................................................13
2-4-1
Radio Triggering Flash Mode ...............................................................................................................13
1) How to use Flash Triggering ...........................................................................................................13
2) How to use Flash Power Control..................................................................................................16
3) How to use Modeling Lamp Power Control ............................................................................20
2-4-2
Radio Triggering Multiple (Cumulative) Flash Mode.................................................................24
1) How to use Flash Triggering ...........................................................................................................24
2) Multi Clear ...............................................................................................................................................27
2-4-3
HSS (High Speed Synchro) Flash Radio Triggering Mode ...................................................28
1) How to use Flash Triggering ...........................................................................................................28
2) How to use Flash Power Control..................................................................................................31
2-4-4
Flash Duration Analysis Radio Triggering Mode.........................................................................35
1) How to use Flash Triggering ...........................................................................................................35
2) How to use Flash Power Control..................................................................................................39
3) Flash Duration Analysis t Value ....................................................................................................43
Table of Contents
■ Safety Precautions ..............................................................................................................................................................i
■ Terms and Trademarks.....................................................................................................................................................i
■ List of Applicable Model ..................................................................................................................................................ii
■ Intended Use ..........................................................................................................................................................................iii
■ Intended Users .....................................................................................................................................................................iii
■ Disclaimer .................................................................................................................................................................................iii
■ Features of the RT-GX....................................................................................................................................................iv
■ Restrictions..............................................................................................................................................................................iv
■ Accompanying Accessories .........................................................................................................................................v
3. Product Information .............................................................................................................................................45
4. Regulation .......................................................................................................................................................................47
5. Radio Channel Frequencies .......................................................................................................................48
6. Specifications .............................................................................................................................................................49
7. Legal Requirements .............................................................................................................................................50
8. Troubleshooting .......................................................................................................................................................51
9. After-sales Services .............................................................................................................................................52
1. Before Use ●
1. Before Use
1-1
Installing the Transmitter
WARNING
● Please refrain from opening the product packaging with wet hands or in a
dusty environment as this may cause damage to the product.
● Keep the materials used in this product out of the reach of children to
prevent accidental ingestion and misuse.
CAUTION
To avoid damage from static electricity, remove the static electricity from
your body by touching metal objects located nearby (e.g. door knob,
aluminum sash) before touching the radio transmitting module.
The numbering below refers to the L-858D Operating Manual.
1. Turn OFF the meter.
2. Unlatch e and remove the Battery Cover d.
3. Remove the Transmitter Connector Cover i.
4. Align the connector pins with those of the Transmitter Module
Compartment h and insert the Transmitter.
Battery Cover d
Transmitter
Battery Cover Latch e
Transmitter Connector
Cover i
Transmitter Connector Cover i
Connector pins
Transmitter Module
Compartment h
Connector pins
1. Before Use ●
5. Insert the Battery Cover d tabs (three) into the receiving holes
in the meter body, press the Battery Cover d down and close the
Battery Cover Latch e.
Battery Cover d
Tabs (three)
Transmitter
Battery Cover Latch e
2. About Godox Radio System ●
2. About Godox Radio System
2-1
Overview
Triggering and controlling Godox Wireless Flash require using Godox Wireless Flash units
receiver attached or installed. Once the transmitter module is installed in your L-858D,
you will be able to adjust the power level and trigger flashes to get the look you desire.
For more information about the meter, refer to the L-858D Operating Manual.
For more information about Godox Wireless radio systems, go to http://www.godox.com/
EN/index.html
NOTICE
Successful radio triggering depends on several factors. Please read these setup steps
before using the L-858D to radio trigger flash units.
1. It is the best to position the meter in sight of the radio receiver (or flash head).
2. Position the radio receiver so that it is away from large metallic objects, concrete, or
containers of water (like people).
3. Sometimes, conditions do not allow radio reception. These could include strong
local radio interference or being near objects that block or absorb the signal.
Repositioning the radio, even slightly, can reestablish contact. Alternatively, check to
see if the radio receiver is behind objects that absorb or block radio waves, such as
concrete, metal or low hill.
4. Operation is the best when the meter to receiver distance is within 30 meters (100
feet).
2. About Godox Radio System ●
2-2
Setting the Radio CH/Group
Set the radio channel and Group used on Godox radio system.
2-2-1
Setting on the Tool Box Screen
Operation
1. Select any Radio Mode in the Measuring Mode Screen.
( P13 “
”, P24 “
”, P28 “
” P35 “
”)
2. Touch the [Tool Box] Icon (
) on the Measuring Screen.
The Tool Box Screen is displayed.
3. Touch the [Next Page] Icon (
) of the Tool Box to display the
Tool Box showing [Radio CH/Group].
4. Touch [Radio CH/Group] Button.
The Radio CH/Group Setting Screen is displayed.
[Measuring Screen]
[Tool Box Screen]
Page 1
[Tool Box Screen]
Page 2
* When the Multiple (Cumu.) Flash mode is selected, the displayed
information are different from those shown above.
[Tool Box] Icon
To Next Page
2. About Godox Radio System ●
5. Select "CH" (Radio Channel) to use.
Touch the arrows
/
, or slide your finger over the screen to select
the channel from 1 to 32.
6. Select the desired Group.
The background color of the selected [Group] Button is displayed in gray.
Select the desired Group by touching a [Group] Button (default setting: A to E).
NOTE
Depending on the Godox products, the number of CH (channel) or the description of Group
could be different. Please check the setting of your receiver (flash).
[Radio CH/Group Setting Screen]
[OK] Button
[Cancel] Button
Radio CH
[ALL] Button
[Radio CH/Group Setting Screen]
[OK] Button
[Cancel] Button
Group
Selected [Group] Button
2. About Godox Radio System ●
7. To change the Group to be displayed, touch the selected Group
again.
Select Group Screen is displayed and a hidden Group can be selected.
Touch the [Group] Button (A to F, 0 to 9) you want to set and select the group.
NOTE
Select Group Screen is not displayed even if touching [ALL] Button twice.
8. Touch [OK] Button.
The setting is entered, and the display returns to the Radio CH/Group Setting
Screen.
Touch the [Cancel] Button to return to the Radio CH/Group Setting Screen without
making the modification.
[Select Group Screen ]
[Group] Button
[Select Group Screen ]
[OK] Button
[Cancel] Button
[Radio CH/Group Setting Screen]
[OK] Button
[Cancel] Button
[Measuring Screen]
Radio
CH/Group
2. About Godox Radio System ●
9. Touch [OK] Button.
The setting is entered, and the display returns to the Measuring Screen.
Touch the [Cancel] Button to return to the Measuring Screen without making the
modification.
NOTE
● The last selected Group in Radio CH/Group Setting Screen is activated in Measuring
Screen.
● It is also possible to select a Group from the Flash Power Control Screen. ( P8)
● For touch/slide operations, refer to the Operating Manual of the light meter.
● For radio CH frequencies, refer to “5. Radio Channel Frequencies”. ( P48)
2. About Godox Radio System ●
Operation
1. Touch the [Flash Power Control] Icon (
) on the Measuring
Screen.
The Flash Power Control Screen is displayed.
2. Touch the Group Setting Button.
The background color of the selected [Group] Button is displayed in gray.
Select the desired Group by touching a [Group] Button (default setting: A to E).
NOTE
Depending on the Godox products, the number of CH (channel) or the description of Group
could be different. Please check the setting of your receiver (flash).
2-2-2
Setting in Measuring Screen (Group setting only)
[Measuring Screen]
[Flash Power Control Screen]
[Flash Power
Control] Icon
[ALL] Button
[Group]
Button
[Flash Power Control Screen]
Selected [Group] Button
2. About Godox Radio System ●
3. To change the Group to be displayed, touch the selected Group
again.
Select Group Screen is displayed and a hidden Group can be selected.
Touch the [Group] Button (A to F, 0 to 9) you want to set and select the group.
NOTE
Select Group Screen is not displayed even if touching [ALL] Button twice.
4. Touch [OK] Button.
The setting is entered, and the display returns to the Flash Power Control Screen.
Touch the [Cancel] Button to return to the Flash Power Control Setting Screen without
making the modification.
5. Touch the [Radio Triggering Flash Mode] Icon(
).
The display returns to the Measuring Screen.
[Select Group Screen ]
[Group] Button
[Select Group Screen ]
[OK] Button
[Cancel] Button
[Flash Power Control Screen]
[Measuring Screen]
[Measuring Mode] Icon
Radio
CH/Group
2. About Godox Radio System ●
NOTE
● The last selected Groups in Radio CH/Group Setting Screen is activated in Measuring
Screen.
● CH can be set only in Radio CH/Group Setting in Tool Box. ( P4)
● For touch/slide operations, refer to the Operating Manual of the light meter.
● For radio CH frequencies, refer to “5. Radio Channel Frequencies”. ( P48)
2. About Godox Radio System ●
2-3
Setting the Wireless ID
To use Wireless ID with Godox radio system, the same Wireless ID should be set to the
light meter. If your receiver (flash) doesn’t have Wireless ID setting, please make sure to
select OFF.
Operation
1. Select any Radio Mode in the Measuring Mode Screen.
( P13 “
”, P24 “
”, P28 “
” P35 “
”)
2. Touch the [Tool Box] Icon (
) on the Measuring Screen.
The Tool Box Screen is displayed.
3. Touch the [Next Page] Icon (
) of the Tool Box to display the
Tool Box showing [Wireless ID].
4. Touch the [Wireless ID] Button.
The Wireless ID Setting Screen is displayed.
[Measuring Screen]
[Tool Box Screen]
Page 1
[Tool Box Screen]
Page 2
* When the Multiple (Cumu.) Flash mode is selected, the displayed
information are different from those shown above.
[Tool Box] Icon
To Next Page
2. About Godox Radio System ●
5. Touch a number to select 1 to 99.
You can set the Wireless ID from 1 to 99 or OFF.
6. Touch [OK] Button.
The setting is entered, and the display returns to the Measuring Screen.
Touch the [Cancel] Button to return to the Measuring Screen without making the
modification.
NOTE
If your receiver (flash) doesn’t have Wireless ID setting, or Wireless ID is set to OFF in the
receiver (flash), please make sure to select OFF on the light meter setting.
[Wireless ID Setting Screen]
The entered
number is
displayed
[Wireless ID Setting Screen]
[OK] Button
[Cancel] Button
[Measuring Screen]
Wireless ID
2. About Godox Radio System ●
2-4
Measuring
Radio Triggering measurement is available in the following modes:
● Radio Triggering Flash Mode
● Radio Triggering Multiple (cumulative) Flash Mode
● HSS (High Speed Synchro) Flash Radio Triggering Mode
● Flash Duration Analysis Radio Triggering Mode
2-4-1
Radio Triggering Flash Mode
The meter detects flash brightness after Measuring Button is pressed to send radio
transmitted signal to radio receiver connected to flash. F-stop value is displayed for input
ISO sensitivity and shutter speed. Depending on the radio system in use, the meter
controls the output power of flash units and the modeling lamps with turning ON/OFF.
Operation
1) How to use Flash Triggering
1. Touch the [Measuring Mode] Icon on the Measuring Mode Screen.
The Measuring Mode Screen is displayed.
2. Touch the [Radio Triggering Flash Mode] Icon (
) in
Measuring Mode Screen.
When it is selected, the display changes to the Measuring Screen.
[Measuring Screen]
[Measuring Mode Screen]
[Measuring Screen]
[Measuring Mode] Icon
2. About Godox Radio System ●
3. Set the light receiving method.
Switch to the incident light, extended lumisphere (
)/retracted lumisphere
(
), or reflected light.
4. Set the ISO sensitivity value on the [ISO]
Icon.
5. Set the shutter speed on the [T] Icon.
NOTICE
Make sure that the settings are within the specifications of the camera and flash system.
6. Make sure that the set CH (channel), Group and Wireless ID
are the same between the light meter and the receivers in use.
(P4, P8, P11)
[Measuring Screen]
Setting Value
Wireless ID
[Measuring Screen]
Radio CH/Group
2. About Godox Radio System ●
7. Press the Measuring Button 6.
The flash will fire and the measured value (F-stop) will be displayed.
NOTICE
In case of the following, please follow “Cord Flash Mode” (
).
● When firing the flash, if the flash brightness is lower than the ambient light, the meter
may fail to detect the light.
● Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash and
accidentally measured.
● Even if the flash does not fire, when a sudden light change occurs in the light receptor,
measurement may be made.
● The waveform of a flash bulb has a slight slope and there is a possibility that the light
meter cannot recognize the flash bulb.
NOTE
● For red-eye prevention and auto-flash light adjustment, some devices can pre-flash
before main flash burst. With the normal setting, the light meter will measure the pre-
flash bursts and not the main flash burst. To take a successful reading, activate the pre-
flash feature in the Tool Box. Please refer to the L-858D Operating Manual.
● For radio CH frequencies, refer to “5. Radio Channel Frequencies”. ( P48)
[Measuring Screen]
Measured value
(F-stop)
2. About Godox Radio System ●
2) How to use Flash Power Control
1. Touch the [Flash Power Control] Icon (
) on the Measuring
Screen.
The Flash Power Control Screen is displayed.
Take measurements by placing the meter at the subject’s position with the light receptor
(retracted lumisphere) facing toward the light sources of main light and fill light directly.
Adjust the measured values for the desired lighting ratio. (Figure 1. of Piv)
2. Select a [Group] Button (default setting: A to E) on the Flash
Power Control Screen.
Only flash unit with the receiver set to the selected Group will fire.
NOTE
To select the group which is not displayed, go to Select Group Screen and select (A to F, 0
to 9). ( P8)
[Measuring Screen]
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[Flash Power Control] Icon
[Group] Button
Group Display
2. About Godox Radio System ●
3. Press the Measuring Button 6.
The flash of the selected Group will fire, and the measured value (F-stop) will be
displayed.
The measured value is displayed in the main display and the Group display over the
selected Group in the Flash Power Control Screen.
4. Touch [+]
or [-]
Button.
Touching the [+] or [-] Button will increase or decrease the power of the flash in
0.1 step for the selected Group. When holding the button longer (1 second), the
power will be adjusted in 1 (full) step.
The adjusted value will be displayed in the Adjusted Value area.
NOTICE
● Default output power is 1/16 for the first flash triggered by light meter, irrespective of the
flash setting.
● Although 1/1 to 1/256 can be set, the adjustment must be within the upper and lower limit
of the power level specification of the flash unit.
Main Display
[Flash Power Control
Screen]
Group Display
Measured
Value
(F-stop)
[Flash Power Control
Screen]
[+] Button
[-] Button
Adjusted Value
2. About Godox Radio System ●
5. Press the Measuring Button 6 again.
The measured value (F-stop) will be displayed. Check that the output power of the
flash is the desired value.
6. Repeat Steps 2 to 5.
Repeat the procedure for other Groups until each flash unit’s brightness is set to
proper value for the effect you want.
7. Touch [ALL] Button, then press the Measuring Button 6.
Point the meter (lumisphere) at the camera from the position of subject to make a
measurement.
All flash units of the selected Group will fire, and the total exposure (F-stop) will be
displayed in the main display. (Figure 2. of Piv)
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[Flash Power Control
Screen]
Main Display
(Measurement
with Extended
Lumisphere)
[ALL] Button
[Flash Power Control
Screen]
[Flash Power Control
Screen]
Switch from
Retracted
Lumisphere
to Extended
One
[ALL] Button
Main Display
(Measurement
with Retracted
Lumisphere)
2. About Godox Radio System ●
8. With [ALL] Button selected, touch [+]
or [-]
Button.
Press the Measuring Button 6 again.
You can adjust the total power level while the lighting ratio of each Group is being
fixed.
NOTICE
● Use the measurement with retracted lumisphere to see the lighting ratio of each Group,
and use the extended lumisphere for final exposure.
● The measurements between extended lumisphere and retracted lumisphere are different
due to light distribution characteristic. When the lumisphere is switched between
extended and retracted status, the measurement on the main display is cleared.
However, on the flash power control screen, the measurements of each Group remain.
● When the lumisphere is switched between extended and retracted status on any screen
except the flash power control screen, the measurements of each Group are all cleared.
Please extend/retract the lumisphere on the flash power control screen.
NOTE
● To set ISO sensitivity and shutter speed, press the [Radio Triggering Flash Mode] Icon
(
) to return to the Measuring Screen.
● The last selected Group in either Flash Power Control Screen or Radio CH/Group Setting
Screen in Tool Box is activated in Measuring Screen.
Difference in step of output value from the default setting value of 1/16
Output value
Difference in Step
Output value
Difference in Step
1/128
-3.0
1/8
+1.0
1/64
-2.0
1/4
+2.0
1/32
-1.0
1/2
+3.0
1/16
±0.0
1/1
+4.0
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[+] Button
[-] Button
[ALL] Button
Main Display
Adjusted Value
2. About Godox Radio System ●
3) How to use Modeling Lamp Power Control
1. Touch the [Modeling Lamp Power Control] Icon (
) on the Flash
Power Control Screen.
The Modeling Lamp Power Control Screen is displayed.
2. Select a [Group] Button (default setting: A to E), and touch the
[Modeling Lamp ON/OFF] Icon (
).
The modeling lamp of the selected flash lights up.
[Flash Power Control
Screen]
[Modeling Lamp Power
Control] Icon
[Modeling Lamp Power
Control Screen]
[Modeling Lamp ON/OFF] Icon
[Group] Button
2. About Godox Radio System ●
3. Press the Measuring Button 6.
The modeling lamp of selected Group is measured.
The measured value is displayed in the main display and the Group display over the
selected Group in the Modeling Lamp Power Control Screen.
4. Touch [+]
or [-]
Button.
Touching the [+] or [-] Button icon will increase or decrease the power of the
modeling lamp in 10% step for the selected Group.
The adjusted power level is displayed on the adjusted value display.
5. Press the Measuring Button 6 again.
Check that the output power of the modeling lamp is the desired value.
NOTICE
● Default output power is 50% for the first measurement of modeling lamp triggered by
light meter, irrespective of the flash setting.
● From 0% to 100% can be set. This setting is not available depending on the model of the
flash.
6. Repeat Steps 2 to 5.
Repeat the procedure for other Groups until each flash unit’s modeling lamp is
set to proper value for the effect you want.
[Modeling Lamp Power
Control Screen]
Measured Value
(F-stop)
Group Display
Main Display
[+] Button
[-] Button
Adjusted Value
[Modeling Lamp Power
Control Screen]
2. About Godox Radio System ●
7. Touch [ALL] Button, then press the Measuring Button 6.
Point the meter (lumisphere) at the camera from the position of subject
to make a measurement.
All modeling lamp of the selected Group will fire, and the total exposure (F-stop) will be
displayed in the main display. (Figure 2. of Piv)
8. With [ALL] Button selected, touch [+]
or [-]
Button.
You can adjust the total power level while the lighting ratio of each Group is being
fixed.
[Modeling Lamp Power
Control Screen]
[ALL] Button
[+] Button
[-] Button
[Flash Power Control] Icon
[Modeling Lamp Power
Control Screen]
[Modeling Lamp Power
Control Screen]
Switch from
Retracted
Lumisphere
to Extended
One
Main Display
(Measurement
with Extended
Lumisphere)
[ALL] Button
[ALL] Button
Main Display
(Measurement
with Retracted
Lumisphere)
2. About Godox Radio System ●
NOTICE
● Use the measurement with retracted lumisphere to see the lighting ratio of each Group,
and use the extended lumisphere for final exposure.
● The measurements between extended lumisphere and retracted lumisphere are different
due to light distribution characteristic. When the lumisphere is switched between
extended and retracted status, the measurement on the main display is cleared.
However, on the modeling lamp power control screen, the measurements of each Group
remain.
● When the lumisphere is switched between extended and retracted status on any screen
except the modeling lamp power control screen, the measurements of each Group are
all cleared. Please extend/retract the lumisphere on the modeling lamp power control
screen.
NOTE
● To set ISO sensitivity and shutter speed, press the [Radio Triggering Flash Mode] Icon
(
) to return to the Measuring Screen.
● The last selected Group in either Flash Power Control Screen, Modeling Lamp Power
Control Screen or Radio CH/Group Setting Screen in Tool Box is activated in Measuring
screen.
● To return to the Flash Power Control Screen again, touch the [Flash Power Control]
Icon (
).
● The measurement in the Modeling Lamp Power Control Screen is made in Ambient
mode. It may not be possible to adjust the power of the modeling lamp depending on the
flash unit or Godox receiver used.
2. About Godox Radio System ●
Operation
1) How to use Flash Triggering
1. Touch the [Measuring Mode] Icon on the Measuring Screen.
The Measuring Mode Screen is displayed.
2. Touch the [Radio Triggering Multi Flash Mode] Icon (
) in
Measuring Mode Screen.
When it is selected, the display changes to the Measuring Screen.
3. Set the light receiving method.
Switch to the incident light, extended lumisphere (
)/retracted lumisphere
(
), or reflected light.
2-4-2
Radio Triggering Multiple (Cumulative) Flash Mode
This Measuring Mode is used when the light generated by the flash at one time is
inadequate for the desired F-stop setting. Repeated flash pops can be accumulated until
the desired F-stop value is displayed. The measured value (F-stop) is displayed for each
trigger of the flash. The cumulative count is infinite. Up to 99 times is displayed in the
Status/Title field, however, the cumulative count returns to 0 (zero) for more than 100
times (0=100, 1=101, 2=102, etc.).
In the Flash Power Control Screen and Modeling Lamp Power Control Screen, the
Multiple (cumulative) flash measurement is not available (only single measurement is
made).
[Measuring Screen]
[Measuring Mode Screen]
[Measuring Screen]
[Measuring Mode] Icon
2. About Godox Radio System ●
4. Set the ISO sensitivity value on the [ISO]
Icon.
5. Set the shutter speed on the [T] Icon.
NOTICE
Make sure that the settings are within the specifications of the camera and flash system.
6. Make sure that the set CH (channel), Group and Wireless ID are the
same between the light meter and the receivers in use.
(P4, P8, P11)
[Measuring Screen]
Setting Value
Wireless ID
[Measuring Screen]
Radio CH/Group
2. About Godox Radio System ●
7. Press the Measuring Button 6.
The measured value (F-stop) will be displayed. Press the Measuring Button 6
again to fire a flash and measure until the desired F-stop is displayed.
The accumulated measured value (F-stop) and the cumulative count will be
displayed.
If you want to adjust the output power of each flash separately, go to Flash Power
Control Screen to make a measurement and adjustment.
In the Flash Power Control Screen, the Multi (cumulative) flash measurement is not
available. ( P16)
NOTICE
● In case of the following, please follow “Cord Multi (Cumu.) Flash Mode” (
).
• When firing the flash, if the flash brightness is lower than the ambient light, the meter
may fail to detect the light.
• Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash
and accidentally measured.
• Even if the flash does not fire, when a sudden light change occurs in the light receptor,
measurement may be made.
• The waveform of a flash bulb has a slight slope and there is a possibility that the light
meter cannot recognize the flash bulb.
● The EV scale cannot be displayed in the Radio Triggering Multi (Cumu.) Flash mode.
NOTE
● For red-eye prevention and auto-flash light adjustment, some devices can pre-flash
before main flash burst. With the normal setting, the light meter will measure the pre-
flash bursts and not the main flash burst. To take a successful reading, activate the pre-
flash feature in the Tool Box. Please refer to the L-858D Operating Manual.
● For radio CH frequencies, refer to "5. Radio Channel Frequencies". ( P48)
[Measuring Screen]
Measured Value
(F-stop)
Cumulative Count
2. About Godox Radio System ●
2) Multi Clear
1. Touch the [Tool Box] Icon (
) on the Measuring Screen.
The Tool Box Screen is displayed.
2. Touch the [Next Page] Icon (
) of the Tool Box to display the
Tool Box showing [Multi Clear].
This button is only enabled during measurement.
If the button is grayed out, the cumulative measurement is not made and the count
cannot be cleared.
3. Touch the [Multi Clear] Button of the Tool Box.
The cumulate value is cleared, and the display returns to the Measuring Screen.
If you do not clear the value, touch the [Close] Button.
The display returns to the Measuring Screen.
[Measuring Screen]
[Tool Box Screen]
Page 1
[Tool Box Screen]
Page 2
[Measuring Screen]
[Cumulative Count]
To Next Page
[Close] Button
Cumulative
Count
Cumulative Count
[Tool Box] Icon
2. About Godox Radio System ●
2-4-3
HSS (High Speed Synchro) Flash Radio Triggering Mode
Select this mode to measure the brightness of a flash activated in HSS (High Speed
Synchro) mode.
Detects flash brightness after Measuring Button is pressed to send radio transmitted
signal to radio receiver connected to flash. Displays F-Stop value.
Depending on the radio system in use, the meter controls the output power of flash unit.
Operation
1) How to use Flash Triggering
1. Touch the [Measuring Mode] Icon on the Measuring Screen.
The Measuring Mode Screen is displayed.
2. Touch the [HSS (High Speed Synchro) Flash Radio Triggering
Mode] Icon (
) in Measuring Mode Screen.
When it is selected, the display changes to the Measuring Screen.
3. Set the light receiving method.
Switch to the incident light, extended lumisphere (
)/retracted lumisphere
(
), or reflected light.
[Measuring Screen]
[Measuring Mode Screen]
[Measuring Screen]
[Measuring Mode] Icon
2. About Godox Radio System ●
4. Set the ISO sensitivity value on the [ISO]
Icon.
5. Set the shutter speed on the [T] Icon.
NOTICE
Make sure that the settings are within the specifications of the camera and flash system.
6. Make sure that the set CH (channel), Group and Wireless ID are the
same between the light meter and the receivers in use.
(P4, P8, P11)
[Measuring Screen]
Setting Value
Wireless ID
[Measuring Screen]
Radio CH/Group
2. About Godox Radio System ●
7. Press the Measuring Button 6.
The flash will fire and the measured value (F-stop) will be displayed.
NOTICE
● In the following cases, measurement may not be possible.
• When firing the flash, if the flash brightness is lower than the ambient light, the meter
may fail to detect the light.
• Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash
and accidentally measured.
• Even if the flash does not fire, when a sudden light change occurs in the light receptor,
measurement may be made.
• The waveform of a flash bulb has a slight slope and there is a possibility that the light
meter cannot recognize the flash bulb.
NOTE
● For red-eye prevention and auto-flash light adjustment, some devices can pre-flash
before main flash burst. With the normal setting, the light meter will measure the pre-
flash bursts and not the main flash burst. To take a successful reading, activate the pre-
flash feature in the Tool Box. Please refer to the L-858D Operating Manual.
● For radio CH frequencies, refer to "5. Radio Channel Frequencies". ( P48)
[Measuring Screen]
Measured Value
(F-stop)
2. About Godox Radio System ●
2) How to use Flash Power Control
1. Touch the [Flash Power Control] Icon (
) on the Measuring
Screen.
The Flash Power Control Screen is displayed.
Take measurements by placing the meter at the subject’s position with the light receptor
(retracted lumisphere) facing toward the light sources of main light and fill light directly.
Adjust the measured values for the desired lighting ratio. (Figure 1. of Piv)
2. Select a [Group] Button (default setting: A to E) on the Flash
Power Control Screen.
Only flash unit with the receiver set to the selected Group will fire.
NOTE
To select the group which is not displayed, go to Select Group Screen and select (A to F, 0
to 9). ( P8)
[Measuring Screen]
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[Flash Power Control] Icon
[Group] Button
Group Display
2. About Godox Radio System ●
3. Press the Measuring Button 6.
The flash of the selected Group will fire, and the measured value (F-stop) will be
displayed.
The measured value is displayed in the main display and the Group display over the
selected Group in the Flash Power Control Screen.
4. Touch [+]
or [-]
Button.
Touching the [+] or [-] Button will increase or decrease the power of the flash in
0.1 step for the selected Group. When holding the button longer (1 second), the
power will be adjusted in 1 (full) step.
The adjusted value will be displayed in the Adjusted Value area.
NOTICE
● Default output power is 1/16 for the first flash triggered by light meter, irrespective of the
setting of flash.
● Although 1/1 to 1/256 can be set, the adjustment must be within the upper and lower limit
of the power level specification of the flash unit.
[Flash Power Control
Screen]
[+] Button
[-] Button
Adjusted Value
[Flash Power Control
Screen]
Group Display
Measured
Value
(F-stop)
Main Display
2. About Godox Radio System ●
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[Flash Power Control
Screen]
5. Press the Measuring Button 6 again.
Check that the output power of the flash is the desired value.
6. Repeat Steps 2 to 5.
Repeat the procedure for other Groups until each flash unit’s brightness is set to
proper value for the effect you want.
7. Touch [ALL] Button, then press the Measuring Button 6.
Point the meter (lumisphere) at the camera from the position of subject to make a
measurement.
All flash units of the selected Group will fire, and the total exposure (F-stop) will be
displayed in the main display. (Figure 2. of Piv)
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[ALL] Button
Switch from
Retracted
Lumisphere
to Extended
One
Main Display
(Measurement
with Extended
Lumisphere)
[ALL] Button
Main Display
(Measurement
with Retracted
Lumisphere)
2. About Godox Radio System ●
8. With [ALL] Button selected, touch [+]
or [-]
Button
Press the Measuring Button 6 again.
You can adjust the total power level while the lighting ratio of each Group is being
fixed.
NOTICE
● Use the measurement with retracted lumisphere to see the lighting ratio of each Group,
and use the extended lumisphere for final exposure.
● The measurements between extended lumisphere and retracted lumisphere are different
due to light distribution characteristic. When the lumisphere is switched between
extended and retracted status, the measurement on the main display is cleared.
However, on the flash power control screen, the measurements of each Group remain.
● When the lumisphere is switched between extended and retracted status on any screen
except the flash power control screen, the measurements of each Group are all cleared.
Please extend/retract the lumisphere on the flash power control screen.
NOTE
● To set ISO sensitivity and shutter speed, press the [HSS (High Speed Synchro) Flash
Radio Triggering Mode] Icon (
) to return to the Measuring Screen.
● The last selected Group in either Flash Power Control Screen or Radio CH/Group Setting
Screen in Tool Box is activated in Measuring Screen.
Difference in step of output value from the default setting value of 1/16
Output value
Difference in Step
Output value
Difference in Step
1/128
-3.0
1/8
+1.0
1/64
-2.0
1/4
+2.0
1/32
-1.0
1/2
+3.0
1/16
±0.0
1/1
+4.0
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[+] Button
[-] Button
[ALL] Button
Main Display
Adjusted Value
2. About Godox Radio System ●
Operation
1) How to use Flash Triggering
1. Touch the [Measuring Mode] Icon on the Measuring Screen.
The Measuring Mode Screen is displayed.
2. Touch the [Flash Duration Analysis Radio Triggering Mode] Icon
(
) in Measuring Mode Screen.
When it is selected, the display changes to the Measuring Screen.
The Flash Duration Analysis Radio Triggering Mode can be selected only when the
incident light is set in the meter.
3. Set the light receiving method.
Switch to the extended lumisphere (
) or retracted lumisphere (
).
2-4-4
Flash Duration Analysis Radio Triggering Mode
The meter detects flash brightness after Measuring Button is pressed to send radio
transmitted signal to radio receiver connected to flash. F-stop, flash duration time and
graph of flash waveform are displayed for input ISO sensitivity and shutter speed.
Depending on the receivers in use, the meter controls the output power of flash units
and modeling lamp with turning ON/OFF, however, flash duration time and graph of
flash waveform are not measured in Modeling Lamp Power Control Screen because it is
ambient light not flash light.
Flash Duration Analysis is performed with Incident Light Measuring Mode.
[Measuring Screen]
[Measuring Mode Screen]
[Measuring Screen]
[Measuring Mode] Icon
2. About Godox Radio System ●
4. Set the ISO sensitivity value on the [ISO]
Icon.
5. Set the shutter speed on the [T] Icon.
NOTICE
Make sure that the settings are within the specifications of the camera and flash system.
6. Set the Flash Duration Analysis t value. ( P43)
7. Make sure that the set CH (channel), Group and Wireless ID
are the same between the light meter and the receivers in use.
(P4, P8, P11)
[Measuring Screen]
Setting Value
Wireless ID
[Measuring Screen]
Radio CH/Group
2. About Godox Radio System ●
8. Press the Measuring Button 6.
The flash will fire, and the flash duration time and the measured value (F-stop) for
input ISO sensitivity and shutter speed will be displayed.
NOTICE
● The flash duration time and graph are displayed in the Flash Duration Analysis Radio
Triggering Mode, however, they cannot be stored in the memory. They are cleared if the
Measuring Mode is changed or the POWER switch is turned OFF.
● The incident light measurement can only be used in Flash Duration Analysis Radio
Triggering mode.
● In case of the followings, please follow “Flash Duration Analysis Cord Mode”(
).
• When firing the flash, if the flash brightness is lower than the ambient light, the meter
may fail to detect the light.
• Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash and
accidentally measured.
• Even if the flash does not fire, when a sudden light change occurs in the light receptor,
measurement may be made.
• The waveform of a flash bulb has a slight slope and there is a possibility that the light
meter cannot recognize the flash bulb.
● If the measured flash duration time is longer than the input
shutter speed, an appropriate F-stop cannot be measured.
The yellow “Under” indication appears. In this case, slower
the shutter speed than the flash duration time and measure
again.
[Measuring Screen]
Measured Value (F-stop)
Flash Duration Time
[Measuring Screen]
2. About Godox Radio System ●
NOTE
● For red-eye prevention and auto-flash light adjustment, some devices can pre-flash before
main flash burst. With the normal setting, the light meter will measure the pre-flash bursts and
not the main flash burst. To take a successful reading, activate the pre-flash feature in the
Tool Box. Please refer to the L-858D Operating Manual.
● When the measured value display area is touched, both flash waveform graph and measured
value are displayed. When it is touched again, the display returns to the previous screen.
● Measure the flash light characteristics in a darkroom without ambient light.
● For radio CH frequencies, refer to “5. Radio Channel Frequencies”. ( P48)
[Measuring Screen]
[Flash Duration Analysis Mode
Flash Waveform Graph Screen]
Touching the
Measured
value area
changes the
display.
* The graph screen cannot be used to make measurements.
2. About Godox Radio System ●
2) How to use Flash Power Control
1. Set the Flash Duration Analysis t value. ( P43)
2. Make sure that the CH (channel), Group and Wireless ID are the
same between the light meter and the receivers in use. ( P4,
P8, P11)
3. Touch the [Flash Power Control] Icon (
) on the Measuring
Screen.
The Flash Power Control Screen is displayed.
4. Select a [Group] Button (default setting: A to E) on the Flash
Power Control Screen.
Only flash unit with the receiver set to the selected Group will fire.
NOTE
To select the group which is not displayed, go to Select Group Screen and select (A to F, 0
to 9). ( P8)
[Measuring Screen]
[Flash Power Control
Screen]
[Flash Power Control
Screen]
[Flash Power Control] Icon
[Group] Button
Group Display
2. About Godox Radio System ●
5. Press the Measuring Button 6.
The flash of the selected Group will fire, and the measured value (F-stop) will be
displayed.
The measured value (F-stop) is displayed in the main display and the Group display
over the selected Group in the Flash Power Control Screen.
6. Touch [+]
or [-]
Button.
Touching the [+] or [-] Button will increase or decrease the power of the flash in
0.1 step for the selected Group. When holding the button longer (1 second), the
power will be adjusted in 1 (full) step.
The adjusted value will be displayed in the Adjusted Value area.
NOTICE
● Default output power is 1/16 for the first flash triggered by light meter, irrespective of the
setting of flash.
● Although 1/1 to 1/256 can be set, the adjustment must be within the upper and lower limit
of the power level specification of the flash unit.
[Flash Power Control
Screen]
Measured Value
(F-stop)
Group Display
Main Display
[Flash Power Control
Screen]
[+] Button
[-] Button
Adjusted Value
2. About Godox Radio System ●
7. Press the Measuring Button 6 again.
Check that the output power of the flash is the desired value.
8. Press the [Flash Duration Analysis Radio Triggering Mode] Icon
(
).
The display returns to the Measuring Screen, and the flash duration time and
the measured value (F-stop) for input ISO sensitivity and shutter speed will be
displayed.
NOTICE
● The measurements between extended lumisphere and retracted lumisphere are different
due to light distribution characteristic. When the lumisphere is switched between
extended and retracted status, the measurement on the main display is cleared.
However, on the flash power control screen, the measurements of each Group remain.
● When the lumisphere is switched between extended and retracted status on any screen
except the flash power control screen, the measurements of each Group are all cleared.
Please extend/retract the lumisphere on the flash power control screen.
[Measuring Screen]
[Flash Duration Analysis
Mode Flash Waveform
Graph Screen]
[Flash Power Control Screen
(After Measurement)]
[Flash Power Control
Screen]
Measured Value
(F-stop)
Group Display
Main Display
[+] Button
[-] Button
Adjusted Value
2. About Godox Radio System ●
NOTE
● When the measured value display area is touched, both flash waveform graph and measured
value are displayed. When it is touched again, the display returns to the previous screen.
● Measure the flash light characteristics in a darkroom without ambient light.
● To set ISO sensitivity and shutter speed, press the [Flash Duration Analysis Radio
Triggering Mode] Icon (
) to return to the Measuring Screen.
● The last selected Group in either Flash Power Control Screen or Radio CH/Group Setting
Screen is activated in Measuring Screen.
● For radio CH frequencies, refer to “5. Radio Channel Frequencies”. ( P48)
[Measuring Screen]
[Flash Duration Analysis
Mode Flash Waveform
Graph Screen]
Touching the
Measured
value area
changes the
display.
* The graph screen cannot be used to make measurements.
2. About Godox Radio System ●
3) Flash Duration Analysis t Value
The t value can be set in steps of 0.1 at a range of 0.1 to 0.9.
The flash duration time varies depending on the input t value.
1. Touch the [Tool Box] Icon (
) on the Measuring Screen.
The Tool Box Screen is displayed.
2. Touch the [Next Page] Icon (
) of the Tool Box to display the
Tool Box showing the [Flash Duration Analysis t Value] Button.
This button is enabled if Flash Duration Analysis Mode is selected. If it is grayed
out, check the Measuring Mode.
3. Touch the [Flash Duration Analysis t Value] Button of the Tool
Box.
The Flash Duration Analysis t Value Screen is displayed.
If you do not change this number, touch the [Close] Button.
[Measuring Screen]
[Tool Box Screen]
Page 1
[Tool Box Screen]
Page 2
To Next Page
[Close] Button
[Tool Box] Icon
2. About Godox Radio System ●
4. Enter the "Reference" of 0.1 to 0.9 by touching the numeric value.
The t value can be set in steps of 0.1 at a range of 0.1 to 0.9.
The first "0." is fixed. Enter the first digit decimal only. (To set "0.1", enter "1".)
5. Touch [OK] Button.
The setting is entered, and the display returns to the Measuring Screen.
Touch the [Cancel] Button to return to the Measuring Screen without making the modification.
NOTE
Two rules apply to the reference flash duration
time.
t0.5 = Effective flash duration time
t0.1 = Total flash duration time
After flash firing, the time at which the
maximum intensity drops by half is called
"t0.5". The time at which the maximum intensity
drops to 1/10 is called "t0.1".
Generally, "t0.5" is called the flash duration
time.
[Flash Duration Analysis
t Value Screen]
[OK] Button
[Cancel] Button
The input
numeric
value is
displayed.
[Measuring Screen]
t 0.1
t 0.2
t 0.3
t 0.4
t 0.5
t 0.6
t 0.7
t 0.8
t 0.9
[Flash Duration Analysis
t Value Screen]
3. Product Information ●
Operation
1. Touch the Menu Button 9 on the meter.
The Menu Screen is displayed.
2. Touch the [Next Page] Icon (
) to display page 2 of the Menu
Screen, and touch the [Product Information] Button.
The Product Information Screen is displayed.
3. Product Information
This screen displays the detailed information not displayed in the Measuring Screen.
[Product Information Screen]
1
2
3
4
5
No.
Item
Description
1
Model Name
Displays the model number of
the meter.
2
Serial Number
Displays the serial number of
the meter.
3
Version
Displays the firmware version.
4
User
Information
Displays user-input information
such as ownership or meter
function, etc which is set in the
Hardware Setting.
5
Radio
Transmitter
Displays the type of radio
system.
* The screen contents
above differ depending
on models.
[Menu Screen]
Page 2
[Product Information
Screen]
[Menu Screen]
Page 2
[Close] Button
[Close] Button
3. Product Information ●
3. Touch the [Close] Button.
The display return to the Menu Screen.
4. Touch the [Close] Button.
The display returns to the Measuring Screen.
4. Regulation ●
Operation
1. Touch the Menu Button 9 on the meter.
The Menu Screen is displayed.
2. Touch the [Next Page] Icon (
) to display page 2 of the Menu
Screen, and touch the [Regulation] Button.
The Regulation Screen is displayed.
3. Touch the [Close] Button.
The display return to the Menu Screen.
4. Touch the [Close] Button.
The display returns to the Measuring Screen.
4. Regulation
The Regulation screen displays the symbols, approved number, regulation names,
etc. which the meter is compliance with.
* The contents on the Regulation Screen vary
depending on the destination or whether a
transmitter (sold separately) is installed.
[Menu Screen]
Page 2
[Regulation Screen]
[Menu Screen]
Page 2
[Close] Button
[Close] Button
5. Radio Channel Frequencies ●
5. Radio Channel Frequencies
Radio CH frequencies (CH 1 to 32)
Channel
Freq. (MHz)
Channel
Freq. (MHz)
1
2413.0
17
2439.5
2
2414.5
18
2441.7
3
2416.0
19
2443.0
4
2418.0
20
2444.5
5
2419.5
21
2446.7
6
2421.0
22
2448.0
7
2423.0
23
2449.5
8
2424.5
24
2451.7
9
2426.7
25
2453.0
10
2428.0
26
2454.5
11
2429.5
27
2456.7
12
2431.7
28
2458.0
13
2433.0
29
2459.5
14
2434.5
30
2461.7
15
2436.2
31
2463.0
16
2438.0
32
2464.5
NOTICE
The working distance of the radio triggering system can vary with the orientation and
location of the meter and receivers.
6. Specifications ●
6. Specifications
Radio Channel Setting Range
● 1 to 32
Radio Group Setting Range
● A to F, 0 to 9, ALL
Wireless ID Setting Range
● OFF, 0 to 99
Radio Triggering Range
● 30 meter (100 feet)
Operating Ambient Temperature
● -10°C to 50°C (no condensation)
Operating Ambient Humidity
● 85% RH or less (at 35°C) (no condensation)
Transportation and Storage Conditions
● Ambient temperature -20°C to 60°C (no condensation)
● Ambient humidity 85% RH or less (at 35°C)
Dimensions
● Approx. 34 (W) mm × 28 (H) mm × 12 (D) mm
Weight
● Approx. 9g
Standard Accessories
● Startup Guide, Safety Precaution
NOTICE
The working distance of the radio triggering system can vary with the orientation
and location of the meter and receivers.
For improvement reasons the specifications and external appearance in this manual may
be subject to future changes without prior notification.
7. Legal Requirements ●
7. Legal Requirements
This product complies with the following legal requirements.
Destination
Standard
Details
Europe
CE
Wireless
EN 300 440
EN 50663
North
America
FCC (US)
Wireless
FCC Part15 SubpartC
IC (Canada)
Wireless
RSS-210
Japan
Radio Act
Certification of construction type prescribed in Article
38-24, paragraph (1) of the Radio Act
FCC & IC compliance information:
Compliance statement to FCC and Industry Canada
FCC ID: 2ABYN-GX
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation. The user is cautioned that unauthorized changes or
modifications not approved could void the user’s authority to operate the equipment.
IC: 20034-GX
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisee aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit
accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d’en
compromettre le fonctionnement.
8. Troubleshooting ●
8. Troubleshooting
If your meter is not operating properly, as you expect, please consult the following
conditions and attempt the suggested solutions before contacting Sekonic. Non-operation
can be due to incorrect, mis-setting of the meter or battery condition. Should your meter
be malfunctioning, please contact place where meter was purchased or Sekonic for
service and repair.
Condition
Possible reasons
What to do
Flash cannot be
triggered in Radio
Triggering Flash
Mode.
Is the radio receiver in the
flash compatible with the
meter’s transmitter? Isn’t any
other non-compatible brand or
manufacturer used?
Make sure that the transmitter
installed to the meter and the
receiver currently used are using the
same radio system.
● Godox website
URL: http://www.godox.com/EN/
index.html
Are the meter transmitter
and receiver set for the same
channel number?
Set the same channel number
and group on the transmitter and
receiver.
Are the transmitter and receiver
set to the same Wireless ID?
Make sure that the transmitter
and receiver are set to the same
Wireless ID when you use it. If
your receiver (flash) doesn’t have
Wireless ID setting, please make
sure to select OFF.
“Radio transmitter
installed cannot be
used in this meter.” is
displayed.
Is the meter updated to the
latest firmware?
Update the meter to the latest
firmware by connecting with
Data Transfer Software which is
downloadable from our website
below.
URL: https://www.sekonic.
com/support/downloads/
dtssoftwareformacandwindows.aspx
9. After-sales Services ●
9. After-sales Services
伪 Contact your local distributor or camera store that you purchased from for
warranty and service.
伪 Even within the warranty period, repair services may be provided on a paid basis.
Check the conditions of warranty provided by local distributor or retailer.
伪 The warranty is not valid unless the copy of proof of purchase with the date
of purchase and the retailer name. Be sure to store such information (bill of
purchase or receipt) in a safe location.
伪 We will retain performance parts for repairs for approximately seven years after
production is discontinued. Therefore, we may not be able to carry out repairs
after this period has elapsed.
伪 When requesting repairs, please provide us with as much detail as possible
about the failure or specific failure locations that you are able to identify. In certain
cases, some products that are returned to us for repairs are not malfunctioning,
and begin to operate normally again when we simply replace the batteries.
Before requesting repairs, please confirm that the batteries are installed in the
correct polarities, contain sufficient charge, and that they match the rating.
7-24-14, Oizumi-Gakuen-cho, Nerima-ku Tokyo
178-8686 JAPAN
Tel +81-3-3978-2335 Fax +81-3-3978-5229
https://www.sekonic.com
JX8N97630
September 2020