DSC MAXSYS PC4010 Instruction Manual
Text of the manual
WARNING: This manual contains information on limitations
regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire
manual should be carefully read.
PC4010 v3.0 • Instruction Manual
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your
authority to use this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Re-orient the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/television technician for help.
The user may find the following booklet prepared by the FCC useful: “How to Identify and Resolve Radio/Television
Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402,
Stock # 004-000-00345-4.
IMPORTANT INFORMATION
This equipment complies with Part 68 of the FCC Rules. On the side of this equipment is a label that contains, among
other information, the FCC registration number of this equipment.
NOTIFICATION TO TELEPHONE COMPANY The customer shall notify the telephone company of the particular
line to which the connection will be made, and provide the FCC registration number and the ringer equivalence of
the protective circuit.
FCC Registration Number: F53CAN-30678-AL-E
Ringer Equivalence Number: 0.1B
USOC Jack: RJ-31X
TELEPHONE CONNECTION REQUIREMENTS Except for the telephone company provided ringers, all
connections to the telephone network shall be made through standard plugs and telephone company provided jacks,
or equivalent, in such a manner as to allow for easy, immediate disconnection of the terminal equipment. Standard
jacks shall be so arranged that, if the plug connected thereto is withdrawn, no interference to the operation of the
equipment at the customer’s premises which remains connected to the telephone network shall occur by reason of such
withdrawal.
INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network,
the telephone company shall, where practicable, notify the customer that temporary disconnection of service may be
required; however, where prior notice is not practicable, the telephone company may temporarily discontinue service
if such action is deemed reasonable in the circumstances. In the case of such temporary discontinuance, the telephone
company shall promptly notify the customer and will be given the opportunity to correct the situation.
ADDITIONAL TELEPHONE COMPANY INFORMATION The security control panel must be properly
connected to the telephone line with a USOC RJ-31X telephone jack.
The FCC prohibits customer-provided terminal equipment be connected to party lines or to be used in conjunction
with coin telephone service. Interconnect rules may vary from state to state.
CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make
changes in its communications facilities, equipment, operations or procedures, where such actions are reasonably
required and proper in its business. Should any such changes render the customer’s terminal equipment incompatible
with the telephone company facilities the customer shall be given adequate notice to the effect modifications to
maintain uninterrupted service.
RINGER EQUIVALENCE NUMBER (REN) The REN is useful to determine the quantity of devices that you may
connect to your telephone line and still have all of those devices ring when your telephone number is called. In most,
but not all areas, the sum of the RENs of all devices connected to one line should not exceed five (5.0). To be certain
of the number of devices that you may connect to your line, you may want to contact your local telephone company.
EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this telephone equipment, please
contact the facility indicated below for information on obtaining service or repairs. The telephone company may ask
that you disconnect this equipment from the network until the problem has been corrected or until you are sure that
the equipment is not malfunctioning.
Digital Security Controls Ltd. 160 Washburn St., Lockport, NY 14094
Section 1: General System Operation
3
1.1
Getting to Know Your System........................................................ 3
1.2
How to Arm ...................................................................................... 4
1.3
Alternate Arming Methods ............................................................ 5
1.4
Disarming.......................................................................................... 6
1.5
Alarm Memory................................................................................. 6
1.6
If An Alarm Sounds ......................................................................... 7
1.7
Zone Bypassing ................................................................................ 7
1.8
Trouble Conditions .......................................................................... 8
Section 2: Access Codes
9
2.1
Program A New Access Code ........................................................ 9
2.2
Modify an Existing Code ...............................................................11
2.3
Change User Code Options.......................................................... 12
2.4
Access Code Label Options .......................................................... 12
2.5
Delete an Existing Code ................................................................ 14
2.6
Special Codes ................................................................................. 14
2.7
Installer Programmed Codes ........................................................ 15
Section 3: System Administration
16
3.1
Quick Arm ...................................................................................... 16
3.2
Quick Exit ........................................................................................ 16
3.3
Auto Arm Control .......................................................................... 16
3.4
Setting the Time and Date ............................................................ 18
3.5
Activating Door Chime ................................................................. 18
3.6
View Event Buffer .......................................................................... 18
3.7
[*][7] Command Outputs 1-8 ........................................................ 19
3.8
Keypad Control .............................................................................. 19
3.9
Downloading Options ................................................................... 19
Section 4: Access Control
21
4.1
Access Card Readers ..................................................................... 21
4.2
Access Card Programming ........................................................... 22
4.3
Search Using Access Card Numbers ........................................... 24
Section 5: Testing and Maintenance
25
5.1
Walk Test ......................................................................................... 25
5.2
System Test ..................................................................................... 26
5.3
Lamp Test (PC4216) ....................................................................... 26
5.4
System Maintenance ..................................................................... 26
Section 6: Fire Safety
27
6.1
Fire Alarm Operation .................................................................... 27
6.2
Guidelines for Locating Smoke Detectors .................................. 27
6.3
Household Fire Safety Audit ........................................................ 29
6.4
Fire Escape Planning ..................................................................... 29
Appendix A – Special Characters
31
Table of Contents
About Your Security System
Your DSC security equipment has been designed to give you the greatest
possible flexibility and convenience. The LCD keypad will guide you
through each operation with English language prompts. The keypad
provides audible feedback each time a key is pressed; with unique audible
sequences, it will also signal system troubles and other indications of
system status.
Read this manual carefully and have your installer instruct you on your
system’s operation. Become familiar with the features that have been
implemented on your system. All users of this system should be equally
instructed in its use.
About this Manual
This manual is a thorough explanation of all system functions, including
troubleshooting and programming access codes in addition to performing
basic system functions. Most users of the system will not need to know
all of this information. The first section of this manual, titled “General
System Operation,” explains general system concepts and instructs the
user on how to arm and disarm the system and bypass zones. Photocopy
this section and distribute it to general users of the system. The remaining
sections of the manual are reserved for more detailed system information.
Fire Detection
This equipment is capable of monitoring fire detection devices such as
smoke detectors and providing a warning alarm if a fire condition is
detected. Good fire detection depends on having adequate numbers of
fire detectors placed in appropriate locations. This equipment should be
installed in accordance with NFPA 72 (NFPA, 1 Batterymarch Park,
Quincey MA 02269). Carefully review the “Fire Escape Planning”
guidelines in this manual.
NOTE: Your installer must enable the fire detection portion of this
equipment before it will work.
Monitoring
This system is capable of transmitting alarms, troubles, and emergency
information over telephone lines to a monitoring station. If you
inadvertently initiate an alarm, immediately call the monitoring station
to prevent an unnecessary response.
NOTE: Your installer must enable the monitoring function before it
will work.
Section 1: General System
Operation
1.1 Getting to Know Your System
Your security system is made up of a control panel, one or more keypads
and various detectors and sensors. The control panel will be mounted
out of the way in a utility room or basement. The metal control cabinet
contains the system’s electronics and stand-by battery. There is normally
no reason for anyone except an installer or service person to have access
to the control panel.
The keypads each have an audible indicator, an alphanumeric liquid
crystal display (LCD), status lights and command entry keys. The keypad
is used to send commands to the system and to display the current system
status. Each keypad will be mounted in convenient locations inside the
protected premises, near designated points of entry/exit.
Zones and Partitions
The protected premises has been divided by your installer into zones and
partitions. A zone is an area of protection that has one or more detection
sensors connected to it (motion detectors, glassbreak detectors, door
contacts or shock sensors). A single zone might be a room, a hallway or a
door or window. Two or more of these zones will be linked together by
the control panel to form a partition.
A partition is a region of the protected premises. A partition can be armed
and disarmed independently from other partitions. All of the partitions
together form the entire system.
Some zones will belong to more than one partition, such as points of entry/
exit and hallways. These are called global zones because they are not
assigned to a single partition.
Access Codes
As a user of the system, you will be assigned a 4- or 6-digit access code.
Access codes are used to arm and disarm the partition(s) to which they
are assigned. Some access codes can perform additional system functions,
such as programming system options and bypassing zones.
Your access code may not allow you to access certain system functions.For
instance, if your code is only allowed to arm and disarm Partition 1, you
will not be able to arm or disarm other partitions, or the entire system.
Keypads
Several LCD keypads will be installed throughout the protected premises,
usually one at each entry/exit door. Some keypads are programmed only
to access a single partition. These are called partition keypads.