United Technologies interlogix 5500 Series Installation Instructions

Specifications

Brand: United Technologies
Category: Security Sensors
Model: interlogix 5500 Series (Installation Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the United Technologies interlogix 5500 Series Installation Instructions online using the built-in PDF viewer.

Text of the manual

© 2019 UTC Fire & Security Americas Corporation, Inc. 1 / 2

P/N 1038436 • REV C • ISS 16JUL19 5500 Moisture Detection Series Installation Instructions Introduction The 5500 Moisture Detection Series is designed to respond to the presence of water and other nonflammable conductive liquids. It is connected in the closed loop of an alarm system. You can use up to four surface-mount 5515 sensors with the 5501 moisture processor. You can use the processor with any closed loop control panel, dialer, or wireless transmitter input circuit. The processor comes with internal lithium batteries with an anticipated life of 10 to 15 years. The processor provides flexibility in mounting with no need for an external power source and minimal required wiring. Operation A time delay circuit is provided to reduce the chance of false alarms. The processor requires the presence of moisture for ten seconds before going into alarm mode. It will stay in alarm mode until the moisture is removed from the sensor. When tripped, the LED will flash at two-second intervals until the sensor is dry. Optical coupling between sensor input and processor output circuits provides isolation from ground. Installation To install the series, do the following: 1. Insert a small, flat-bladed screwdriver in the slot at the top or bottom of the processor and pry the cover off the base. 2. Mount the processor using the mounting holes shown in Figure 1 below. 3. Mount the 5515 sensors to any surface and in any position, using screws or double-sided tape. Wiring Wire the sensors in parallel (Figure 1 below). You do not need to observe polarity. The connection for output on the processor, however, is polarity sensitive. Trigger the processor and allow the control panel, dialer, or transmitter to operate to verify the connection. Testing Press the test button (Figure 1 below) for 15 seconds to simulate the presence of water and activate the processor (the LED will flash). Release the button to restore the processor to normal operation. Figure 1: 5500 moisture detection series

5500 Moisture Detection Series Installation Instructions

Dimensions Figure 2: Dimensions Specifications Loop type Closed Battery type Lithium Battery life Approximately 10 to 15 years Alarm response 10 seconds delay, then on as long as wet Test button Simulates moisture for test LED Flashes every 2 seconds on alarm Trigger response 500 K ohm Sensor isolation from ground Photo coupled Sensing circuit AC to eliminate electrolysis (1 Hz) Cable Length 100 ft. (30 m) maximum Loop resistance 10 ohms maximum (nonalarm) 1 M ohm minimum (alarm) Operating temperature 5501 processor 5515 sensors 0 to 125°F (-17 to 51°C) 33 to 180°F (0 to 82°C) Number of sensors per processor 4 maximum Ordering information Model # Description Loop type Color Lead 5501 Moisture processor Closed Mahogany brown Terminals 5515 Surface- mount sensor NA Gray 10 ft. (3 m) Regulatory information Manufacturer PLACED ON THE MARKET BY: UTC Fire & Security Americas Corporation, Inc. 3211 Progress Drive, Lincolnton, NC, 28092, USA AUTHORIZED EU REPRESENTATIVE: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands Product warnings and disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS. For more information on warranty disclaimers and product safety information, please check https://firesecurityproducts.com/policy/product- warning/ or scan the QR code. Contact information www.utcfireandsecurity.com or www.interlogix.com For customer support, see www.interlogix.com/customer- support

Other Security Sensors Manuals