Using the Ultimate Duo 400W Charger with a

RangePro X8 RP6S24KHDA Battery Pack Toll Free: +1 (800) 628-3119 Phone: +1 (301) 263-7321 Support: https://terraview.com/contact/ Web: www.terraview.com Part Number: TSN0001, Rev. A Revised: January 17, 2020

Using the D400 Charger with a RangePro X8 Battery

© 2020 Terraview 360, Inc. 2 Part Number: TSN0001, Rev A Contents 1. Introduction .......................................................................................................................................... 3 2. Modify and Verify System Settings ....................................................................................................... 4 3. Program Battery Memory Charge Settings ........................................................................................... 5 4. Balance Charge the Battery using Battery Memory #1 ........................................................................ 6 5. Troubleshooting Common Charging Errors .......................................................................................... 7

Using the D400 Charger with a RangePro X8 Battery

© 2020 Terraview 360, Inc. 3 Part Number: TSN0001, Rev A 1. Introduction The Range Pro X8 RP6S24KHDA is a dual 6S2P, 24,000 mAh, high density, battery pack consisting of two independent 6S2P Lithium Ion Polymer battery packs installed in a single battery cage. The battery packs are impedance matched at the factory, placed in a common cage, and wired independently to a single connector. On the aircraft the unit provides a blind mating power solution with easy insertion and extraction from the system using a dovetail rail system and latching mechanism. The power pins from both battery packs, though housed in the same connector, are independently routed to the aircraft power distribution board. For charging, power and balance port connectors are separately wired for each battery pack and broken out for connection to a charger using a custom cable. To connect the RP6S24KHDA to the SKYRC Ultimate Duo 400W (D400) Balance Charger, use the RPBCCA400-12 twelve-inch cable that includes a battery mating connector on one end and two sets of power and balance ports on the other. Custom cable lengths are available upon request. This document provides instructions on how to customize the D400 charger for use with the RP6S24KHDA battery as well as some common troubleshooting steps for addressing issues that may arise when the unit is not set up correctly. For additional details on how to use the D400, refer to the Ultimate Duo Instruction Manual provided with the charger.

Using the D400 Charger with a RangePro X8 Battery

© 2020 Terraview 360, Inc. 4 Part Number: TSN0001, Rev A 2. Modify and Verify System Settings Verify the correct system settings for BOTH charging channels using the following steps. a. Power on the Ultimate Duo 400W Charger (D400). b. Press the STATUS “+” or “–“ button for the channel until the display screen reads: BATT/PROGRAM SYSTEM SETTING-> c. Press ENTER “” to review the system settings. d. To scroll from one parameter to another, use the STATUS “+” or “–“ buttons. e. To change the value of a parameter enter into editing mode by pressing ENTER “”. f. In editing mode, the value of the selected parameter will blink slowly. Press the STATUS “+” or “–“ button to adjust the parameter value. When the value is set correctly exit the editing mode by pressing the Enter “” button. Some screens contain two parameters. In this case, pressing the Enter “” button will close editing for the first parameter and open editing for the second parameter. Pressing Enter “” a second time will close editing on the second parameter. Parameter Channel 1 Value(s) Channel 2 Value(s) Max Power Set 200W 200W Synchronization* OFF N/A Safety Timer ON 150Min ON 150Min Capacity Cut-Off ON 12600mAh ON 12600mAh Temp Cut-Off ON 50C 122F ON 50C 122F Temperature Unit Celsius Celsius Rest Time CHG\DCHG 10Min 10Min NiMH Sensitivity N/A N/A NiCd Sensitivity N/A N/A Key Beep ON ON Buzzer ON ON DC Input Low Cut-Off 11.0 V 11.0 V Balance Port Enable Enable Load Factory Set (See Manual) (See Manual) g. When all system settings for the channel have been properly set and verified, press the BATT/PROG “” button to return to the main menu. h. If not already completed, repeat steps 2.b through 2.g for the other charging channel. *In most cases Synchronization can be set to ON but it is important to note that in rare cases Synchronization may prevent one side or another from charging properly if there is a significant mismatch between battery states. Also note that while Synchronization will ensure the same program is being used by both sides of the charger, in the case of custom Battery Memory programs it does not ensure that the programs for each channel are identical. Battery Memory programs must be independently set on each side of the charger.

Using the D400 Charger with a RangePro X8 Battery

© 2020 Terraview 360, Inc. 5 Part Number: TSN0001, Rev A 3. Program Battery Memory Charge Settings Verify the correct Battery Memory settings for BOTH charging channels using the following steps. a. Power on the Ultimate Duo 400W Charger (D400). b. Press the STATUS “+” or “–“ button for the channel until the screen reads: BATT/PROGRAM BATT MEMORY c. Press ENTER “” to gain access to the ten (10) battery memory locations. d. Use the STATUS “+” or “–“ buttons to scroll through the locations until the screen reads: [ BATT MEMORY 1] ENTER SET-> e. Press ENTER “” to verify the correct setting for Battery Memory 1. f. To scroll from one parameter to another, use the STATUS “+” or “–“ buttons g. To change the value of a parameter enter into editing mode by pressing ENTER “” h. In editing mode, the value of the selected parameter will blink slowly. Press the STATUS “+” or “–“ button to adjust the parameter value. When the value is set correctly exit the editing mode by pressing the Enter “” button. Parameter Channel 1 Value(s) Channel 2 Value(s) BATT TYPE LiHV LiHV BATT VOLTAGE 22.8V(6S) 22.8V(6S) CHARGE CURRENT 6.0A 6.0A DSCHG CURRENT 3.0A 3.0A DSCHG VOLTAGE 3.2V/CELL 3.2V/CELL TVC=YOUR RISK! 4.30V 4.30V SAVE PROGRAM (see below) (see below) i. When all system settings for the channel have been properly set and verified it is necessary to save the programmed values. The last option in the parameter list is “SAVE PROGRAM”. To save the program press the Enter “” button. On the screen the word “ENTER” will disappear and be replaced with the word “SAVE….” When these memory settings have been saved the display screen will return to the Battery Memory screen and alternate between the following: [ BATT MEMORY 1] LiHV 22.8V(6S) [ BATT MEMORY 1] C:6.0A D:3.0A j. Press the BATT/PROG “” button to return to the main menu. k. If not already completed, repeat steps 3.b through 0 for the other charging channel. CRITICAL NOTE: Anytime the BATT TYPE is changed and the program saved, the TVC (Terminal Voltage Charge) is reset to the default voltage for that battery type and will remain at the default value until manually changed by the user. Prior to saving the program always confirm the TVC is set to the correct value!