TerraView RangePro X8 Manual
Text of the manual
Using the Ultimate Duo 400W Charger with a
RangePro X8 RP6S24KHDA Battery Pack
Toll Free: +1 (800) 628-3119
Phone: +1 (301) 263-7321
Support: https://terraview.com/contact/
Web: www.terraview.com
Part Number: TSN0001, Rev. A
Revised: January 17, 2020
Using the D400 Charger with a RangePro X8 Battery
© 2020 Terraview 360, Inc.
2
Part Number: TSN0001, Rev A
Contents
1.
Introduction .......................................................................................................................................... 3
2.
Modify and Verify System Settings ....................................................................................................... 4
3.
Program Battery Memory Charge Settings ........................................................................................... 5
4.
Balance Charge the Battery using Battery Memory #1 ........................................................................ 6
5.
Troubleshooting Common Charging Errors .......................................................................................... 7
Using the D400 Charger with a RangePro X8 Battery
© 2020 Terraview 360, Inc.
3
Part Number: TSN0001, Rev A
1. Introduction
The Range Pro X8 RP6S24KHDA is a dual 6S2P, 24,000 mAh, high density, battery pack consisting of two
independent 6S2P Lithium Ion Polymer battery packs installed in a single battery cage. The battery
packs are impedance matched at the factory, placed in a common cage, and wired independently to a
single connector.
On the aircraft the unit provides a blind mating power solution with easy insertion and extraction from
the system using a dovetail rail system and latching mechanism. The power pins from both battery
packs, though housed in the same connector, are independently routed to the aircraft power
distribution board.
For charging, power and balance port connectors are separately wired for each battery pack and broken
out for connection to a charger using a custom cable. To connect the RP6S24KHDA to the SKYRC
Ultimate Duo 400W (D400) Balance Charger, use the RPBCCA400-12 twelve-inch cable that includes a
battery mating connector on one end and two sets of power and balance ports on the other. Custom
cable lengths are available upon request.
This document provides instructions on how to customize the D400 charger for use with the
RP6S24KHDA battery as well as some common troubleshooting steps for addressing issues that may
arise when the unit is not set up correctly. For additional details on how to use the D400, refer to the
Ultimate Duo Instruction Manual provided with the charger.
Using the D400 Charger with a RangePro X8 Battery
© 2020 Terraview 360, Inc.
4
Part Number: TSN0001, Rev A
2. Modify and Verify System Settings
Verify the correct system settings for BOTH charging channels using the following steps.
a. Power on the Ultimate Duo 400W Charger (D400).
b. Press the STATUS “+” or “–“ button for the channel until the display screen reads:
BATT/PROGRAM
SYSTEM SETTING->
c. Press ENTER “” to review the system settings.
d. To scroll from one parameter to another, use the STATUS “+” or “–“ buttons.
e. To change the value of a parameter enter into editing mode by pressing ENTER “”.
f. In editing mode, the value of the selected parameter will blink slowly. Press the STATUS “+” or
“–“ button to adjust the parameter value. When the value is set correctly exit the editing mode
by pressing the Enter “” button. Some screens contain two parameters. In this case, pressing
the Enter “” button will close editing for the first parameter and open editing for the second
parameter. Pressing Enter “” a second time will close editing on the second parameter.
Parameter
Channel 1 Value(s)
Channel 2 Value(s)
Max Power Set
200W
200W
Synchronization*
OFF
N/A
Safety Timer
ON 150Min
ON 150Min
Capacity Cut-Off
ON 12600mAh
ON 12600mAh
Temp Cut-Off
ON 50C 122F
ON 50C 122F
Temperature Unit
Celsius
Celsius
Rest Time CHG\DCHG
10Min
10Min
NiMH Sensitivity
N/A
N/A
NiCd Sensitivity
N/A
N/A
Key Beep
ON
ON
Buzzer
ON
ON
DC Input Low Cut-Off
11.0 V
11.0 V
Balance Port
Enable
Enable
Load Factory Set
(See Manual)
(See Manual)
g. When all system settings for the channel have been properly set and verified, press the
BATT/PROG “” button to return to the main menu.
h. If not already completed, repeat steps 2.b through 2.g for the other charging channel.
*In most cases Synchronization can be set to ON but it is important to note that in rare cases
Synchronization may prevent one side or another from charging properly if there is a significant
mismatch between battery states. Also note that while Synchronization will ensure the same program is
being used by both sides of the charger, in the case of custom Battery Memory programs it does not
ensure that the programs for each channel are identical. Battery Memory programs must be
independently set on each side of the charger.
Using the D400 Charger with a RangePro X8 Battery
© 2020 Terraview 360, Inc.
5
Part Number: TSN0001, Rev A
3. Program Battery Memory Charge Settings
Verify the correct Battery Memory settings for BOTH charging channels using the following steps.
a. Power on the Ultimate Duo 400W Charger (D400).
b. Press the STATUS “+” or “–“ button for the channel until the screen reads:
BATT/PROGRAM
BATT MEMORY
c. Press ENTER “” to gain access to the ten (10) battery memory locations.
d. Use the STATUS “+” or “–“ buttons to scroll through the locations until the screen reads:
[ BATT MEMORY 1]
ENTER SET->
e. Press ENTER “” to verify the correct setting for Battery Memory 1.
f. To scroll from one parameter to another, use the STATUS “+” or “–“ buttons
g. To change the value of a parameter enter into editing mode by pressing ENTER “”
h. In editing mode, the value of the selected parameter will blink slowly. Press the STATUS “+” or
“–“ button to adjust the parameter value. When the value is set correctly exit the editing mode
by pressing the Enter “” button.
Parameter
Channel 1 Value(s)
Channel 2 Value(s)
BATT TYPE
LiHV
LiHV
BATT VOLTAGE
22.8V(6S)
22.8V(6S)
CHARGE CURRENT
6.0A
6.0A
DSCHG CURRENT
3.0A
3.0A
DSCHG VOLTAGE
3.2V/CELL
3.2V/CELL
TVC=YOUR RISK!
4.30V
4.30V
SAVE PROGRAM
(see below)
(see below)
i.
When all system settings for the channel have been properly set and verified it is necessary to
save the programmed values. The last option in the parameter list is “SAVE PROGRAM”. To
save the program press the Enter “” button. On the screen the word “ENTER” will disappear
and be replaced with the word “SAVE….” When these memory settings have been saved the
display screen will return to the Battery Memory screen and alternate between the following:
[ BATT MEMORY 1]
LiHV 22.8V(6S)
[ BATT MEMORY 1]
C:6.0A D:3.0A
j.
Press the BATT/PROG “” button to return to the main menu.
k. If not already completed, repeat steps 3.b through 0 for the other charging channel.
CRITICAL NOTE:
Anytime the BATT TYPE is changed and the program saved, the TVC (Terminal Voltage Charge) is reset
to the default voltage for that battery type and will remain at the default value until manually
changed by the user. Prior to saving the program always confirm the TVC is set to the correct value!