Forza max di spinta

Force maxi de poussée Thrust force Max. Schubkraft Fuerza max de empuje codice code code code codigo KING 230V 50Hz 220V 60Hz 120V 60Hz N 1800 AA14001 AA14002 AA14003 con Encoder avec Encoder with Encoder mit Encoder con Encoder Peso max cancello Poids maxi portail Max gate weight Max Torgewicht Peso máx verja 400 kg / 880 lbs KING PLUS 230V 50Hz 220V 60Hz 120V 60Hz N 1800 AA14016 AA14017 AA14018 X 400 kg / 880 lbs KING L 230V 50Hz 220V 60Hz 120V 60Hz N 1800 AA14010 AA14011 AA14012 500 kg / 1100 lbs KING L PLUS 230V 50Hz 220V 60Hz 120V 60Hz N 1800 AA14026 AA14025 AA14024 X 500 kg / 1100 lbs OPERATORE IRREVERSIBILE PER CANCELLI A BATTENTE OPERATEUR IRREVERSIBLE POUR PORTAILS À BATTANT IRREVERSIBLE OPERATOR FOR LEAF GATES TORANTRIEBE FÜR FLÜGELTORE OPERADOR IRREVERSIBLE PARA CANCELAS DE BATIENTE ITALIANO pag. 05 / FRANÇAIS pag. 13 / ENGLISH page 21 / DEUTSCH pag. 29 / ESPAÑOL pag. 37

CONSERVARE CON CURA QUESTE ISTRUZIONI

1° - Se non é previsto nella centralina elettrica, installare a monte della medesima un'interruttore di tipo magnetotermico (onnipolare con apertura minima dei contatti pari a 3mm) che riporti un marchio di conformità alle normative internazionali. Tale dispositivo deve essere protetto contro la richiusura accidentale (ad esempio installandolo dentro quadro chiuso a chiave). 2° - Per la sezione ed il tipo dei cavi la RIB consiglia di utilizzare un cavo di tipo H05RN-F con sezione minima di 1,5mm2 e comunque di attenersi alla norma IEC 364 e alle norme di installazione vigenti nel proprio Paese. 3° - Posizionamento di un’eventuale coppia di fotocellule: Il raggio delle fotocellule deve essere ad un’altezza non superiore a 70 cm dal suolo e ad una distanza dal piano di movimento dell’anta non superiore a 20 cm. Il loro corretto funzionamento deve essere verificato a fine installazione in accordo al punto 7.2.1 della EN 12445. 4° - Per il soddisfacimento dei limiti imposti dalla EN 12453, se la forza di picco supera il limite normativo di 400 N è necessario ricorrere alla rilevazione di presenza attiva sull’intera altezza del cancello (fino a 2,5m max) - Le fotocellule in questo caso sono da applicare all’esterno tra le colonne ed all’interno per tutta la corsa della parte mobile ogni 60÷70cm per tutta l’altezza delle colonne del cancello fino ad un massimo di 2,5m (EN 12445 punto 7.3.2.1) - es. colonne alte 2,2m => 6 coppie di fotocellule - 3 interne e 3 esterne (meglio se dotate di sincronismo - 6 FIT SYNCRO con 2 TX SYNCRO). N.B.:É obbligatoria la messa a terra dell'impianto I dati descritti nel presente manuale sono puramente indicativi. La RIB si riserva di modificarli in qualsiasi momento. Realizzare l’impianto in ottemperanza alle norme ed alle leggi vigenti. SEGUIRE TUTTE LE ISTRUZIONI DI INSTALLAZIONE 1° - Questo libretto d'istruzioni è rivolto esclusivamente a del personale specializzato che sia a conoscenza dei criteri costruttivi e dei dispositivi di protezione contro gli infortuni per i cancelli, le porte e i portoni motorizzati (attenersi alle norme e alle leggi vigenti). 2° - L’installatore dovrà rilasciare all’utente finale un libretto di istruzioni in accordo alla EN 12635. 3° - L’installatore prima di procedere con l’installazione deve prevedere l’analisi dei rischi della chiusura automatizzata finale e la messa in sicurezza dei punti pericolosi identificati (seguendo le norme EN 12453/EN 12445). 4° - Il cablaggio dei vari componenti elettrici esterni all’operatore (ad esempio fotocellule, lampeggianti, ecc.) deve essere effettuato secondo la EN 60204-1 e le modifiche a questa apportate dal punto 5.2.2 della EN 12453. 5° - L’eventuale montaggio di una pulsantiera per il comando manuale del movimento deve essere fatto posizionando la pulsantiera in modo che chi la aziona non si trovi in posizione pericolosa; inoltre si dovrà fare in modo che sia ridotto il rischio di azionamento accidentale dei pulsanti. 6° - Tenete i comandi dell'automatismo (pulsantiera, telecomando etc.) fuori dalla portata dei bambini. I comandi devono essere posti ad un’altezza minima di 1,5m dal suolo e fuori dal raggio d’azione delle parti mobili. 7° - Prima di eseguire qualsiasi operazione di installazione, regolazione, manutenzione dell’impianto, togliere la tensione agendo sull’apposito interruttore magnetotermico collegato a monte dello stesso. LA DITTA RIB NON ACCETTA NESSUNA RESPONSABILITÀ per eventuali danni provocati dalla mancata osservanza nell'installazione delle norme di sicurezza e delle leggi attualmente in vigore. ISTRUZIONI DI SICUREZZA IMPORTANTI PER L’INSTALLAZIONE - ATTENZIONE - PER LA SICUREZZA DELLE PERSONE É IMPORTANTE CHE VENGANO SEGUITE TUTTE LE ISTRUZIONI CONSERVER SOIGNEUSEMENT CES INSTRUCTIONS 1° - Si la centrale électrique ne dispose d'aucun interrupteur, il faut en installer un de type magnétothermique en amont de cette dernière (omnipolaire avec ouverture minimale des contacts correspondant à 3mm); la marque de cet interrupteur devra être en conformité avec les normes internationales. Ce dispositif doit être protégé contre toute remise en fonction accidentelle (ex. en l’installant dans un coffre fermant à clé). 2° - En ce qui concerne la section et le type des câbles, le conseil de la RIB est celui d'utiliser un câble de type H05RN-F présentant une section minimale de 1,5mm2 et, quoi qu'il en soit, de se conformer à la norme IEC 364, ainsi qu'aux normes d'installation en vigueur dans le pays de destination. 3° - Positionnement d’un éventuel jeu de photocellules : le faisceau des photocellules ne doit pas être à une hauteur supérieure à 70 cm du sol et 20 cm du bord du vantail. Leur correct effectivité fonctionnement doit être vérifié terminant l’installation, selon le point de la 7.2.1 de la EN 12445. 4° - Afin de satisfaire aux limites imposées par la norme EN 12453, si la force d’impact dépasse la limite de 400N, il sera nécessaire de détecter une présence sur la hauteur totale du portail (jusqu'à un maximum de 2,5m) - Les cellules photo-électriques dans ce cas- ci doivent être s'appliquent extérieurement entre les colums et intérieurement pour toute la course de la pièce de mobil chaque 60÷70cm pour toute la taille de la colonne de la porte jusqu'à un maximum de 2,5m (EN 12445 point 7.3.2.1) - exemple: taille 2,2m de colonne = > 6 copies des cellules photo-électriques - 3 internes et 3 externes (meilleur si complet du dispositif de syncronism - FIT SYNCRO avec TX SYNCRO). N.B.:La mise à terre de l'installation est obligatoire. Les données figurant dans le présent manuel sont fournies à titre purement indicatif. La RIB se réserve le droit de les modifier à tout moment, sans aucun préavis. Effectuer l'installation en conformité avec les normes et les lois en vigueur. SUIVRE TOUTES LES INSTRUCTIONS D’INSTALLATION 1° - Ce livret d’instructions est adressé exclusivement à un personnel spécialisé qui connaît les critères de construction et les dispositifs de protection contre les accidents concernant les portails, les portes et les grandes portes motorisés (s’en tenir aux normes et aux lois en vigueur). 2° - L’installateur devra délivrer à l’utilisateur final un livret d’instruction en accord à la EN 12635. 3° - L’installateur avant de procéder à l’installation, doit prévoir l’analyse des risques de la fermeture automatisée finale et la mise en sécurité des points identifiés dangereux (en suivant les normes EN 12453/EN 12445). 4° - Le câblage des divers composants électriques externes à l’opérateur (par exemple photocellules, clignotants, etc) doit être effectué selon la EN 60204-1 et les modifications apportées à celle-ci dans le point 5.2.2 de la EN 12453. 5° - Le montage éventuel d’un tableau pour la commande manuelle du mouvement doit être fait en positionnant le tableau de façon à ce que la personne qui l’actionne ne se trouve pas en position de danger ; de plus, il faudra faire en sorte que le risque d’actionnement accidentel des boutons soit réduit. 6° - Tenir les commandes de l’automatisme (tableau, télécommande, etc) hors de portée des enfants. Les commandes doivent être placées à une hauteur minimum de 1,5 m du sol et hors du rayon d’action des parties mobiles. 7° - Avant l’exécution de toute opération d’installation, de réglage, d’entretien de l’installation, couper le courant en agissant sur l’interrupteur magnétothermique à cet effet, branché en amont de l’installation. LA SOCIETE RIB N’ACCEPTE AUCUNE RESPONSABILITE pour d’éventuels dommages provoqués par la non-observation dans l’installation, des normes de sécurité et des lois actuellement en vigueur. INSTRUCTIONS DE SECURITE IMPORTANTES POUR L’INSTALLATION - ATTENTION - POUR LA SECURITE DES PERSONNES IL EST IMPORTANT QUE TOUTES LES INSTRUCTIONS SOIENT SUIVIES I F

KEEP THESE INSTRUCTIONS WITH CARE

1° - Install a thermal magnetic switch (omnipolar, with a minimum contact opening of 3 mm) before the control board, in case this is not provided with it. The switch shall be guaranteed by a mark of compliance with international standards. Such a device must be protected against accidental closing (e.g. Installing it inside the control panel key locked container). 2° - As far as the cable section and the cable kind are concerned, RIB suggests to use an H05RN-F cable, with a minimum section of 1,5mm2, and to follow, In any case, the IEC 364 standard and Installation regulations In force In your Country. 3° - Positioning of an eventual pair of photocells: The beam of the photocells must be at an height not above the 70 cm from the ground, and, should not be more than 20 cm away from the axis of operation of the gate (Sliding track for sliding gate or door, and the hinges for the swing gate). In accordance with the point 7.2.1 of EN 12445 their correct functioning must be checked once the whole installation has been completed. 4° - In order to comply with the limits defined by the EN 12453 norm, if the peak force is higher than the limit of 400N set by the norm, it is necessary to use an active obstacle detection system on the whole height of the gate (up to a maximum of 2,5m) - The photocells in this case must be apply externally between the colums and internally for all the race of the mobil part every 60÷70cm for all the height of the column of the gate up to a maximum of 2,5m (EN 12445 point 7.3.2.1). example: column height 2,2m => 6 copies of photocells - 3 internal and 3 external (better if complete of syncronism feature - FIT SYNCRO with TX SYNCRO). N.B.: The system must be grounded Data described by this manual are only Indicative and RIB reserves to modify them at any time. Install the system complying with current standards and regulations. FOLLOW ALL INSTALLATION INSTRUCTIONS 1° - This handbook is exclusively addressed to the specialized personnel who knows the constructive criteria and the protection devices against the accidents for motorized gates, doors and main doors (follow the standards and the laws in force). 2° - The installer will have to issue to the final user a handbook in accordance with the EN 12635. 3° - Before proceeding with the installation, the installer must forecast the risks analysis of the final automatized closing and the safety of the identified dangerous points (following the standards EN 12453/EN 12445). 4° - The wiring harness of the different electric components external to the operator (for example photoelectric cells, flashlights etc.) must be carried out according to the EN 60204-1 and the modifications to it done in the point 5.2.2 of the EN 12453. 5° - The possible assembly of a keyboard for the manual control of the movement must be done by positioning the keyboard so that the person operating it does not find himself in a dangerous position; moreover, the risk of accidental activation of the buttons must be reduced. 6° - Keep the automatism controls (push-button panel, remote control etc.) out of the children way. The controls must be placed at a minimum height of 1,5m from the ground and outside the range of the mobile parts. 7° - Before carrying out any installation, regulation or maintenance operation of the system, take off the voltage by operating on the special magnetothermic switch connected upstream it. THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages caused by the non observance during the installation of the safety standards and of the laws in force at present. IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION - ATTENTION – FOR THE SAFETY OF THE PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE INSTRUCTIONS. INSTALLATIONSVORSCHRIFTEN BEACHTET WERDEN 1° - Wenn nicht bereits an der elektrischen Schaltzentrale vorgesehen, muss vor der Schaltzentrale ein thermomagnetischer Schalter installiert werden (omnipolar, mit einer minimalen Kontaktöffnung von 3 mm), der ein von den internationalen Normen anerkanntes Konformitätszeichen besitzt. Solch ein Geraet muss vor Vandalismus geschuetzt werden(z.B.mit einen Schluesselkatsten in einem Panzergehaeuse) 2° - RIB empfiehlt den Kabeltyp H05RN-F mit einem minimalen Querschnitt von 1,5mm2 generell sollten die Normative IEC 364 und alle anderen geltenden Montagenormen des Bestimmungslandes eingehalten werden. 3°- Position des ersten paar Fotozellen: Der sollten nicht hoeher als 70cm vom Boden sein, und sollte nicht mehr als 20 cm entfernt von der Achse des Tores sitzen (das gilt fuer Schiebe und Drehtore). In Übereinstimmung mit dem Punkt 7.2.1 der EN 12445 Norm, ihr korrektes Funktionieren muß einmal überprüft werden. 4°- In Einklang mit der Norm EN12453, ist es bei Toren notwendig eine komplette Sicherheitslieiste zu installieren, bei denen mehr als 400N Kraft aufgewand werden muessen, um das Tor zum anhalten zu bringen (Maximum von 2,5m anwenden) - Die Fotozellen müssen in diesem Fall sein beantragen außen zwischen den colums und innerlich das ganzes Rennen des mobil Teils jede 60÷70cm für die ganze Höhe der Spalte des Gatters bis zu einem Maximum von 2,5m - EN 12445 Punkt 7.3.2.1). Beispiel: Spalte Höhe 2,2m => 6 Kopien von Fotozellen - 3 intern und 3 extern (besser, wenn komplett von der syncronism Eigenschaft - FIT SYNCRO mit TX SYNCRO). ANMERKUNG: Die Erdung der Anlage ist obligatorisch Die in diesem Handbuch aufgeführten Daten sind ausschließlich empfohlene Werte. RIB behält sich das Recht vor, das Produkt zu jedem Zeitpunkt zu modifizieren. Die Anlage muss in Übereinstimmung mit den gültigen Normen und Gesetzen montiert werden. ALLE INSTALLATIONSANLEITUNGEN BEFOLGEN 1° - Diese Betriebsanleitung dient ausschließlich dem Fachpersonal, welche die Konstruktionskriterien und die Sicherheits-Vorschriften gegen Unfälle für Tore, Türen und automatische Tore kennt (geltende Normen und Gesetze beachten und befolgen). 2° - Der Monteur muss dem Endkunde eine Betriebsanleitung in Übereinkunft der EN12635 überreichen. 3° - Vor der Installierung muss für die automatische Schließung und zur Sicherheitsgewährung der identifizierten kritischen Punkte, eine Risiko Analyse vorgenommen werden mit der entsprechenden Behebung der identifizierten, gefährlichen Punkte. (die Normen EN 12453/EN 12445 befolgend). 4° - Die Verkabelung der verschiedenen externen elektrischen Komponenten zum Operator (z.B. Fotozellen, Blinker etc.) muss nach EN 60204-1 ausgeführt werden, Änderungen davon nach Punkt 5.2.2 der EN 12453. 5° - Die eventuelle Montage einer Schalttafel für den manuellen Bewegungsbefehl muss so angebracht werden, dass der Benutzer sich nicht in einer Gefahrenzone befindet, und dass, das Risiko einer zufälligen nicht gewollten Aktivierung von Schaltern gering ist. 6° - Alle Steuerungselemente (Schalttafel, Fernbedienung etc.) gehören nicht in Reichweite von Kindern. Die Kommandos müssen min. 1,5 m ab Boden und außerhalb des Aktionsbereiches der mobilen Teile angebracht werden. 7° - Vor jeglichem Eingriff, sei es Installation, Regulation oder Wartung der Anlage, muss vorher die Stromzufuhr unterbrochen werden, den dafür bestimmten Magnetthermo-Schalter drücken, der am Eingang der Anlage installiert ist. DIE FIRMA RIB ÜBERNIMMT KEINE VERANTWORTUNG für eventuelle Schäden, die entstehen können, wenn die Installierungsvorschriften die den gültigen Sicherheitsnormen entsprechen, nicht eingehalten werden. WICHTIGE SICHERHEITS ANLEITUNGEN FÜR DIE INSTALLATIONEN - ACHTUNG – FÜR DIE SICHERHEIT DER PERSONEN IST ES WICHTIG, DASS ALLE ANWEISUNGEN GENAU AUSGEFÜHRT WERDEN G B DD

CONSERVAR CUIDADOSAMENTE ESTAS INSTRUCCIONES

1° - En el caso de que no sea previsto en la central eléctrica, instalar antes de la misma, un interruptor de tipo magnetotérmico (omnipolar con una abertura mínima de los contactos de 3mm) que dé un sello de conformidad con las normas internacionales. Este dispositivo tiene que estar protegido contra cierres accidentales (por ejemplo instalándolo dentro de un panel cerrado a llave). 2° - Para la sección y el tipo de los cables, la RIB aconseja utilizar cables de tipo H05RN-F con sección mínima de 1,5mm2 e igualmente atenerse a la norma IEC 364 y a las normas de instalación del propio País. 3° - Posicionamiento eventual de un par de fotocélulas. El rayo de las fotocélulas no debe estar a más de 70 cm de altura desde el suelo y a una distancia de la superficie de movimiento de la puerta, no superior a 20 cm. El correcto funcionamiento tiene que ser controlado al final de la instalación de acuerdo con el punto 7.2.1 de la EN 12445. 4° - Para satisfascer los límites impuestos por la EN 12453, si la fuerza de punta supera el límite normativo de 400 N, es necesario recurrir al control de presencia activa en toda la altura de la puerta (hasta a 2,5m max). Las fotocélulas en este caso se tienen que colocar en el exterior entre las columnas y en el interior por todo el recorrido de la parte móvil cada 60÷70cm en toda la altura de las columnas de la cancela hasta un máximo de 2,5m (EN 12445 punto 7.3.2.1) - es. columnas altas de 2,2m => 6 par de fotocélulas - 3 internas y 3 externas (mejor si están provistas de sincronismo - 6 FIT SYNCRO con 2 TX SYNCRO). PS.:Es obligatorio la puesta a tierra del sistema. Los datos descritos en el presente manual son sólamente indicativos. La RIB se reserva de modificarlos en cualquier momento. Realizar el sistema respetando las normas y las leyes vigentes. SEGUIR TODAS LAS INSTRUCCIONES DE INSTALACIÓN 1° - Este manual de instrucciones está exclusivamente dirigido a personal especializado que conozca los criterios de construcción y de los dispositivos de protección contra accidentes con cancelas, puertas y portales motorizados (atenerse a las normas y a las leyes vigentes). 2° - El instalador tendrá que dar al utilizador final un manual de instrucciones de acuerdo con la EN 12635. 3° - El instalador antes de proceder con la instalación tiene que hacer una analisis de los riesgos del cierre automatizado final y la puesta en seguridad de los puntos identificados como peligrosos (siguiendo las normas EN 12453 / EN 12445). 4° - El cablaje de los varios componentes eléctricos externos al operador (por ejemplo fotocélulas, los intermitentes, etc) tiene que ser efectuado según la EN 60204-1 y a las modificas sucesivas aportadas por el punto 5.2.2 della EN 12453. 5° - El eventual montaje de un panel de mandos para la gestión del movimiento manual tiene que ser efectuado posicionando el panel en modo que quién lo accione no se encuentre en una posición peligrosa; además se tiene que hacer en modo que el riesgo de accionamiento accidental de los pulsadores sea mínimo. 6° -Tener los mandos del automatismo (panel de mandos, mando a distancia, etc.) lejos del alcance de los niños. Los mandos tienen que ser puestoa una altura mínima de 1,5m del suelo y fuera del radio de acción de las partes móviles. 7° - Antes de ejecutar cualquier operación de instalación, ajuste o mantenimiento del sistema, quitar la corriente accionando el respectivo interruptor magnetotérmico conectado antes del mismo. LA EMPRESA RIB NO ES RESPONSABLE por eventuales daños provocados por la falta de respeto de las normas de seguridad, durante la instalación y de las leyes actualmente vigentes. IMPORTANTES INSTRUCCIONES DE SEGURIDAD PARA LA INSTALACIÓN - CUIDADO - UNA INCORRECTA INSTALACIÓN PUEDE CAUSAR GRAVES DAÑOS E S

1 - Operatore KING

2 - Antenna radio 3 - Lampeggiatore 4 - Selettore a chiave 5 - Fotocellule esterne CARATTERISTICHE TECNICHE KING è una serie di operatori irreversibili, utilizzati per movimentare cancelli a battente con ante lunghe fino a 4,5 m (Fig. 1). La serie KING è stata concepita per funzionare senza finecorsa elettrici, ma solo meccanici. Quando è arrivato in battuta il motore funziona ancora per qualche secondo, fino a quando non interviene il timer di funzionamento della centralina di comando (o l’ENCODER se versione PLUS). I † ‚ ‚ † ƒ „ Misure in mm KING L L=1020 L1=945 L2=470 KING L=888 L1=815 L2=340 1 S / Encod M 2 + 3 GND * SOLO KING PLUS * 1 V 2 W 3 U Encoder CARATTERISTICHE TECNICHE Lunghezza max. anta Peso max cancello Corsa max di traino Tempo medio di apertura Velocità di traino Forza max di spinta Alimentazione e frequenza CEE Potenza motore Assorbimento Condensatore Cicli normativi Cicli consigliati al giorno Servizio Cicli consecutivi garantiti Lubrificazione a grasso Peso motore Rumorosità Volume Temperatura di lavoro Grado di protezione m 3,5* 4,5* kg 400 500 mm 345** 475** s. 14÷27 29÷38 m/s. 0,0125 N 1800 230V~ 50Hz W 290 A 1,2 µF 10 n° 17 - 14s/2s 10 - 33s/2s n° 150 60% n° 20/14s 15/33s Bechem - RHUS 550 kg 10 14 db <70 m3 0,0184 0,0211 °C -10 ÷ +55°C IP 447 ** Con fermo meccanico incorporato che interviene durante l'apertura. Se si utilizza anche il fermo meccanico che interviene durante la chiusura, opzionale, la corsa massima di traino si riduce di 50 mm. KING KING L 1

Le ante devono essere solidamente fissate ai cardini delle colonne, non

devono flettere durante il movimento e devono muoversi senza attriti. Prima d'installare KING è meglio verificare tutti gli ingombri necessari per poterlo installare. Se il cancello si presenta come da Fig. 1 non occorrono modifiche. È obbligatorio uniformare le caratteristiche del cancello alle norme e leggi vigenti. Il cancello può essere automatizzato solo se in buono stato e se rispondente alla norma EN 12604. - L’anta non deve presentare porte pedonali. In caso contrario occorrerà prendere opportune precauzioni in accordo al punto 5.4.1 della EN12453 (ad esempio impedire il movimento del motore quando il portoncino è aperto, grazie ad un microinterruttore opportunamente collegato in centralina). - Non bisogna generare punti di intrappolamento (ad esempio tra anta aperta del cancello e cancellata). - Non devono essere presenti fermi meccanici al di sopra del cancello perché non sono sufficientemente sicuri. FISSAGGIO ATTACCO MOTORE A COLONNA Durante l’installazione di KING è necessario rispettare alcune misure per avere un corretto movimento dell'anta (vedi le TABELLE delle misure). ATTACCO COLONNA PER OPERATORE KING (cod. CCA1293 - CCA1294) Se la colonna è in ferro le si può avvitare direttamente l’attacco utilizzando quattro viti filettate M8. Se la colonna è in cemento fissare l’attacco con quattro viti ad espansione di Ø 8 mm (Fig. 2-3). In caso si abbia il muro parallelo al cancello quando questo è aperto, può essere necessario praticare una nicchia per dare una sede all’operatore. ATTACCO COLONNA PER OPERATORE KING L (cod. CCA1370 - CCA1319) Se la colonna è in ferro le si può saldare direttamente l'attacco. Se la colonna è in cemento si utilizza la piastra come in Fig. 5 e la si fissa con quattro viti ad espansione di Ø 8 mm. Altro intervento possibile consiste nel murare l'attacco nella colonna saldandogli alla base una zanca come in Fig. 6. Proseguendo nell'installazione si deve saldare sull'anta l'attacco per il traino del cancello, osservando naturalmente le quote previste (Fig. 7). Nel caso in cui il muro si presenti parallelo al cancello aperto, può essere necessario praticare una nicchia per dare una sede all’operatore. INSTALLAZIONE KING I TIPO DI COMANDO USO DELLA CHIUSURA Persone esperte Persone esperte Uso illimitato (fuori da area pubblica*) (area pubblica) a uomo presente A B non possibile a impulsi in vista C o E C o E C e D, o E (es. sensore) a impulsi non in vista C o E C e D, o E C e D, o E (es. telecomando) automatico C e D, o E C e D, o E C e D, o E * esempio tipico sono le chiusure che non accedono a pubblica via A: Pulsante di comando a uomo presente (cioè ad azione mantenuta), come cod. ACG2013 B: Selettore a chiave a uomo presente, come cod. ACG1010 C: Regolazione della forza del motore D: Dispositivo encoder (PLUS) oppure costole come cod. ACG3010 e/o altri dispositivi di limitazione delle forze entro i limiti della norma EN12453 - Appendice A. E: Fotocellule, es. cod.ACG8026 (Da applicare ogni 60÷70cm per tutta l’altezza della colonna del cancello fino ad un massimo di 2,5m - EN 12445 punto 7.3.2.1) Componenti da installare secondo la norma EN12453 2 4 7 6 5 3

FISSAGGIO ATTACCO MOTORE A CANCELLO

(vedi le TABELLE delle misure) Saldare l’attacco a cancello alla giusta altezza (Fig. 8). Durante l’installazione aprire e chiudere più volte il cancello controllando che i semigusci non sfreghino contro l’anta in movimento. I 9 8 ANT Attacco anta KING S2 S3 S1 Z Y X Z Y X Z Y X COL Attacco colonna KING ANT KING L Attacco anta KING Lungo A B C D

* Oltre i 2,5 metri di lunghezza d’anta deve essere applicata una elettroserratura per

assicurare un’efficace chiusura. Qualora il pilastro fosse molto largo e non fosse possibile installare l'operatore rispettando la misura (B), è indispensabile creare una nicchia nel pilastro o spostare il cancello sullo spigolo. ANT Attacco anta S1 Z Y X COL Attacco colonna KING S3-Y S3-X S1-Z S2-Y S2-Y - - S1-Z S2-Y S1-Y - - - S3-Y S3-X S1-Z S1-Y - - COL COL COL S1-Z S2-Y S1-Y - - 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 90° 45 100 100 775 90 14 A 45 110 110 775 90 18 A 70 140 110 775 115 20 B 70 160 140 775 115 25 B 60 170 170 905 120 23 C 100 190 180 905 120 25 C L Min.÷Max α A max T sec B C D E ANT ANT 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 110° 20 90 140 775 90 20 A 100 130 775 90 21 A 110 140 775 115 24 B 130 140 905 120 18 C 130 150 905 120 19 C L Min.÷Max α A max T sec B C D E KING KING KING KING KING L KING L KING KING KING KING L KING L 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 4,01*÷4,50* 90° 45 100 100 815 90 14 A 45 110 110 815 90 18 A 70 140 110 815 90 20 A 90 170 140 815 115 25 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min.÷Max α A max T sec B C D E 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 110° 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min.÷Max α A max T sec B C D E ANT ANT KING KING KING KING KING KING L KING L KING KING KING KING L KING L KING L COL MISURE DA RISPETTARE PER UNA CORRETTA INSTALLAZIONE FERMO MECCANICO - OPTIONAL Cod. ACG8089 Fermo meccanico, optional, per fermare la chiusura in caso il cancello sia privo di un fermo a terra (Fig. 11). MISURE DA RISPETTARE CON 2 FERMI MECCANICI B A C D ANT KING L Attacco anta KING Lungo

REGOLAZIONE FINECORSA MECCANICI

Per posizionare i fermi agire come da schema (Fig. 12). Per ottenere l'apertura desiderata è sufficiente spostare il fermo (A) e bloccarlo serrando la vite da 8mA con una chiave fissa n°13. Per ottenere la chiusura desiderata si dovrà spostare il fermo (B) (OPZIONALE) bloccandolo come descritto per il fermo (A). SBLOCCO DI EMERGENZA In caso di mancanza di corrente, per poter agire manualmente sul cancello è sufficiente inserire l’apposita chiave e ruotarla 3 volte in senso antiorario (Fig. 14). Per poter eseguire in modo sicuro la movimentazione manuale dell’anta occorre verificare che: - sull’anta siano presenti maniglie idonee; - tali maniglie siano posizionate in modo da non creare punti di pericolo durante il loro utilizzo; - lo sforzo manuale per muovere l’anta non superi i 225N per i cancelli posti su siti privati ed i 390N per i cancelli posti su siti commerciali ed industriali (valori indicati nel punto 5.3.5 della norma EN 12453). ATTENZIONE: Sbloccando i KING PLUS con tensione presente e muovendo le ante, gli encoder perdono il riferimento della posizione delle ante. Per ripristinare il corretto funzionamento del cancello sarà necessario togliere e ridare corrente e successivamente dare un comando. SICUREZZE ELETTRICHE Realizzare l’impianto in ottemperanza alle norme ed alle leggi vigenti. I modelli KING PLUS monofasi sono dotati di ENCODER per il rilevamento ostacolo. In caso di ostacolo durante la corsa questi operatori invertono immediatamente il movimento evitando così il pericolo di schiacciamento o trascinamento, come richiesto dalle norme europee EN12453 e EN12445), senza dover applicare bordi sensibili. Si consiglia l'utilizzo delle centraline elettroniche di comando: - KS2 o T2 per 1 o 2 KING monofasi. Non sono utilizzabili i quadri T2 per gestire gli ENCODER dei KING PLUS monofasi. Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi manuali. COLLEGAMENTO ALIMENTAZIONE Nei KING monofasi si devono collegare i morsetti 1-2-3 del connettore del motore rispettivamente ai morsetti V-W-U del quadro di comando. COLLEGAMENTO ENCODER (solo versioni PLUS) I KING PLUS sono dotati di ENCODER incorporato. Collegare i morsetti 1 / 2 / 3 del connettore dell’ENCODER (5Vdc) ai morsetti S / + / GND. ATTENZIONE! La lunghezza max dei cavi di collegamento dai motori alla centralina deve essere di 15 m max con sezione filo per alimentazione motore di 2,5 mm2, per gli accessori utilizzare una sezione di filo di 0,75 mm2 e per l'encoder utilizzare un cavo schermato 3x0,75mm2 (per esempio il tipo ÖLFLEX-110 CH - Cod. ACG2133). Il cavo schermato per l’encoder è da utilizzare obbligatoriamente per garantire il corretto funzionamento dell’apparecchiatura. Per garantire il corretto funzionamento dell’impianto si consiglia di eseguire i collegamenti dell’encoder e del motore installando cavi separati. REGOLAZIONE FORZA DI SPINTA Per i KING monofasi è necessario utilizzare un quadro elettronico tipo KS2 o T2 dotato di regolatore di forza elettronico. Per i KING PLUS, l’operatore é dotato di un ENCODER per determinare il rilevamento di un’ostacolo e per gestire questo tipo di operatore si consiglia l'utilizzo delle centraline elettroniche di comando KS2. MANUTENZIONE Da effettuare solamente da parte di personale specializzato dopo aver tolto l'alimentazione elettrica. Ogni anno ingrassare i cardini e controllare la forza di spinta esercitata dall’operatore sull'anta. Ogni due anni è consigliabile lubrificare la madrevite con del grasso siliconico. 12 I 13 14

KS2 (per KING PLUS - KING L PLUS)

cod. ABKS105 => 230V cod. ABKS104 => 120V Autoapprendimento corsa e tempi Chiusura automatica Prelampeggio Rallentamento in chiusura Regolazione della forza Comando radio automatico o passo passo Comando singolo automatico o passo passo Comandi direzionali apre (con gestione orologio) e chiude Colpo di sgancio serratura elettrica Comando di stop Gestione attuatori con encoder Gestione fotocellule Gestione lampeggiatore Gestione coste Selettore a chiave Buzzer Serratura elettrica T2 (per KING - KING L - KING ICE - KING FAST) cod. ABT2000 => CRX 230/50-60HZ cod. ABT2001 => 230/50-60HZ cod. ABT2002 => CRX 120/60HZ cod. ABT2003 => 120/60HZ Autoapprendimento corsa e tempi Apertura pedonale Chiusura automatica totale e pedonale Prelampeggio Rallentamento regolabile in accostamento Regolazione della forza Comando radio automatico o passo passo Comando singolo automatico o passo passo Colpo d’ariete serratura elettrica Radio ricevitore incorporato Gestione fotocellule Gestione lampeggiatore Gestione coste Autotest coste di sicurezza come richiesto da norma EN12453 Selettore a chiave Buzzer Serratura elettrica I OPTIONAL - Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione.

SCHEDA EXPANDER PLEX PER KS2

COME EXPANDER CON IN PIÙ: - AUTOTEST DI QUATTRO FOTOCELLULE - AUTOTEST COSTA * NON PER EXPANDER PLEX cod. ACG5472 SCHEDA EXPANDER PER KS2 !! INNESTARE LA SCHEDA EXPANDER IN ASSENZA DI CORRENTE !! - APERTURA PEDONALE - CHIUSURA AUTOMATICA PEDONALE - GESTIONE COSTA - ALIMENTAZIONE PER ACCESSORI A 24VAC - GESTIONE SEMAFORO - GESTIONE LUCE DI CORTESIA - CHIUSURA DOPO IL PASSAGGIO DAVANTI ALLE FOTOCELLULE* cod. ACG5470 I D5 D4 D3 D2 CAVO ENCODER PER KS2 Il cavo schermato per l’ENCODER è da utilizzare obbligatoriamente per garantire il corretto funzionamento dell’operatore KING PLUS. Il cavo dell’ENCODER deve avere ad una estremità la schermatura collegata a terra (non a GND scheda), e all’altra estremità non deve essere collegata a nulla (filo libero). cod. ACG2133 BLOCK SELETTORE A CHIAVE DA PARETE cod. ACG1053 SELETTORE A CHIAVE DA INCASSO cod. ACG1048 RADIO RICEVITORI AD AUTOAPPRENDIMENTO RX91/A quarzata con innesto cod. ACG5005 RX91/A quarzata con morsettiera cod. ACG5004 RX433/A supereterodina con innesto cod. ACG5055 RX433/A supereterodina con morsettiera cod. ACG5056 RX433/A 2CH supereterodina bicanale con innesto cod. ACG5051 RX433/A 2CH supereterodina bicanale con morsettiera cod. ACG5052 433 cod. ACG6081 433 cod. ACG6082 91 cod. ACG7025 91 cod. ACG7026 cod. ACG6093 MOON 433 - MOON 91 MOON CLONE TELECOMANDO MOON PULSANTIERA FLAT Con collegamento a motore cod. ACG2012 Con collegamento a centralina cod. ACG2013

COPPIA DI COLONNINE PER FIT SLIM

cod. ACG8065 FIT SLIM FOTOCELLULE DA PARETE cod. ACG8032 Le fotocellule FIT SLIM hanno la funzione di sincronismo in corrente alternata e portata di 20m. Sono applicabili più coppie di fotocellule ravvicinate grazie al circuito sincronizzatore. Aggiungere il TRASMETTITORE TX SLIM SYNCRO cod. ACG8029 per sincronizzare fino a 4 coppie di fotocellule. I SPARK Per ottenere le migliori prestazioni degli apparati sopracitati, bisogna installare un’antenna accordata sulla frequenza del radio ricevitore installato . N.B. Fare molta attenzione che il filo centrale del cavo non vada a contatto con la calza in rame esterna, ciò renderebbe nullo il funzionamento dell’antenna. L’antenna va installata perpendicolarmente e deve essere in vista del telecomando. ANTENNA SPARK 91 cod. ACG5454 ANTENNA SPARK 433 cod. ACG5452 LAMPEGGIATORE SPARK con scheda intermittente incorporata cod. ACG7059 CHIAVISTELLO MECCANICO Chiavistello meccanico per cancelli a due ante. cod. ACG5000

1 - Operateur KING

2 - Antenne radio 3 - Signal electrique 4 - Selecteur 5 - Photocellules p/protection externe CARACTERISTIQUES TECHNIQUES KING est une série de operateur irréversibles, utilisé pour movimenter des portails à battans jusqu'à 4,5 m de longeur (Fig. 1). Lorsqu'il arrive en fin de course, le moteur marche encore pendant quelques secondes, tant que n'intervient pas le temporisateur de fonctionnement de l'unité de commande (ou le CODEUR si version PLUS). † ‚ ‚ † ƒ „ Mesures en mm KING L L=1020 L1=945 L2=470 KING L=888 L1=815 L2=340 1 S / Encod M 2 + 3 GND * SEUL KING PLUS * 1 V 2 W 3 U Encoder 1 F SCHÉMA DÉTAILLÉ DE L’INSTALLATION CARACTERISTIQUES TECHNIQUES Longueur maxi du battant Poids maxi du portail Course maxi d'entrainement Temps moyen d'ouverture Vitesse de traction Force maxi de poussée Alimentation et frequence CEE Puissance moteur Absorption Condensateur Cycles normatifs Cycles conseillés par jour Service Cycles consécutifs garantis Graisse Poids du moteur Bruit Volume Temperature de travail Indìce de protection m 3,5* 4,5* kg 400 500 mm 345** 475** s. 14÷27 29÷38 m/s. 0,0125 N 1800 230V~ 50Hz W 290 A 1,2 µF 10 n° 17 - 14s/2s 10 - 33s/2s n° 150 60% n° 20/14s 15/33s Bechem - RHUS 550 kg 10 14 db <70 m3 0,0184 0,0211 °C -10 ÷ +55°C IP 447 ** Avec une butée mécanique incorporée qui intervient pendant l’ouverture. Si l’on utilise aussi la butée mécanique qui intervient pendant la fermeture, en option, la course maximale d’entraînement s’écourte de 50 mm. KING KING L

Le portail à battant doit être solidement fixé aux cardans des colonnes,

ne doit pas flechir pendant le mouvement et doit pouvoir manoeuvrer sans effort. Avant d'installer KING, il convient de verifier tous les encombrements necessaires pour proceder à l'installation. Si le portail se presente comme indiqué Fig. 2, aucune modification n'est necessaire. Il est impératif d'uniformiser les caractéristiques du portail avec les normes et les lois en vigueur. Le portail peut être automatisé seulement si il est en bon état et qu’il est conforme à la norme EN 12604. - Le vantail ne doit pas comporter de portillon intégré. Dans le cas contraire, il sera opportun de prendre les précautions décrites au point 5.4.1 de la EN 12453 (interdire, par le biais d’un contact raccordé aux bornes adaptées de la platine électronique, la mise en marche de l’automatisme si le portillon est ouvert). - Ne pas générer de zone d’écrasement (par exemple entre le vantail ouvert et la cloture). - Il ne devra y avoir aucun arrêt mécanique au-dessus du portail, étant donné que les arrêts mécaniques ne sont pas suffisamment sûrs. FIXATION DE L'ATTACHEMENT DU MOTEUR A LA COLONNE Lors de l'installation du KING, il est necessaire de respecter certaines mesures afin d'obtenir un mouvement correct du vantail (voir les TABLEAUX des mesures). ATTACHE POTEAU POUR OPERATEUR KING (code CCA1293 - CCA1294) Si la colonne est en fer, l'attaque peut être baisée directement à l'aide de quatre vis M8. Si la colonne est en béton, l'attaque peut être fixée avec quatre vis d'expansion Ø 8 mm (fig. 2 ou 3). En cas de mur parallèle au portail lorsque celui-ci est ouvert il est necessaire de pratiquer une niche pour loger le motoreducteur. ATTACHE POTEAU POUR OPERATEUR KING L (code CCA1370 - CCA1319) Si la colonne est en fer, il est possible de sonder directement la fixation. Si la colonne est en ciment, proceder toujours avec une plaque comme indique Fig. 5, et la fixer avec quatre Fischer de Ø 8 mm. Il est aussi possible de sceller la fixation dans la colonne en soudant une agrafe a sa base, voir Fig. 6. Ensuite poursuivre l'installation en soudant sur le vantail la fixation pour le dispositif d'entrainement du portail, en respectant les mesures prevues (Fig. 7). En cas de mur parallèle au portail lorsque celui-ci est ouvert il est necessaire de pratiquer une niche pour loger le motoreducteur. 2 4 7 6 5 3 TYPE DE COMMANDE USAGE DE LA FERMETURE Personne expertes Personne expertes Usage illimité (au dehors d’une zone publique*) (zone publique) homme presente A B non possible impulsion en vue C ou E C ou E C et D, ou E (es. capteur) impulsion hors de vue C ou E C et D, ou E C et D, ou E (es. boîtier de commande) automatique C et D, ou E C et D, ou E C et D, ou E * example typique: fermetures qui n’ont pas d’accès à un chemin public A: Touche de commande à homme present (à action maintenue), code ACG2013. B: Sélecteur à clef à homme mort, code ACG1010. C: Réglage de la puissance du moteur. D: Disposif encodeur (PLUS) ou cordon de securité, cod. ACG3010 et/ou autres dispositifs de limitation des forces dans les limites de la norme EN12453- appendice A. E: Cellules photo-électriques, code ACG8026 (Appliquer chaque 60÷70cm pour toute la taille de la colonne de la porte jusqu'à un maximum de 2,5m - EN 12445 point 7.3.2.1). Parties à installer conformément à la norme EN12453

FIXATION DE L'ATTACHEMENT DU MOTEUR AUX

PORTAILS (voir les TABLEAUX des mesures). Souder le socle à la juste hauteur (Fig. 8). Installer le KING en essayant plusieurs fois d'ouvrir et de fermer en controlant que le profile cache-vis ne frotte pas lorsque le portail est en mouvement. 9 8 ANT Attache vantail KING S2 S3 S1 Z Y X Z Y X Z Y X COL Attache poteau KING ANT KING L Attache vantail KING L A B C D

* Les vantaux de plus de 2,50 mètres de langeur nécessitent l’installation d’une

élettroserrure pou garantir une fermeture efficace Si le pilier est très large et n'est pas possible d'installer le motoreducteur en respectant la mesure (B), il faut realiser une niche dans le pilier ou deplacer le portail sur l'arete. ANT Attache vantail S1 Z Y X COL Attache poteau KING MESURES A RESPECTER POUR UNE CORRECTE INSTALLATION FARRÊT MÉCANIQUE - OPTION Code ACG8089 Arrêt mécanique en option pour arrêter la fermeture si le portail n'est pas pourvu de dispositif d'arrêt au sol (Fig. 11). MESURES DE RESPECTER AVEC DEUX ARRET MECANIQUES S3-Y S3-X S1-Z S2-Y S2-Y - - S1-Z S2-Y S1-Y - - - S3-Y S3-X S1-Z S1-Y - - COL COL COL S1-Z S2-Y S1-Y - - 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 90° 45 100 100 775 90 14 A 45 110 110 775 90 18 A 70 140 110 775 115 20 B 70 160 140 775 115 25 B 60 170 170 905 120 23 C 100 190 180 905 120 25 C L Min.÷Max α A max T sec B C D E ANT ANT 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 110° 20 90 140 775 90 20 A 100 130 775 90 21 A 110 140 775 115 24 B 130 140 905 120 18 C 130 150 905 120 19 C L Min.÷Max α A max T sec B C D E KING KING KING KING KING L KING L KING KING KING KING L KING L 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 4,01*÷4,50* 90° 45 100 100 815 90 14 A 45 110 110 815 90 18 A 70 140 110 815 90 20 A 90 170 140 815 115 25 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min.÷Max α A max T sec B C D E 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 110° 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min.÷Max α A max T sec B C D E ANT ANT KING KING KING KING KING KING L KING L KING KING KING KING L KING L KING L COL B A C D ANT KING L Attache vantail KING L

REGLAGE FINS DE COURSE MECANIQUES

Pour positionner les colliers, il est necessaire agir selon les indications du schema (Fig. 12). Pour obtenir l'ouverture desirée, il suffit de déplacer le collier (A) et de le bloquer en vissant la vis M8 avec une clé n° 13. Pour obtenir la fermeture desirée, il est necessarie de deplacer le collier (B) (OPTIONAL) et de le bloquer comme indiqué ci-dessus. MANOEUVRE DE SECOURS Pour actionner le portail manuellement il est necessaire introduire la clé appropriée dans la serrure et la tourner 3 fois dans le sense anti-horarie (Fig. 14). Afin de pouvoir manœuvre manuellement le vantail, il est important de vérifier que : - Il soit fourni des poignées adaptées sur le vantail; - Ces poignées doivent être positionnées de sorte à ne pas créer un danger durant leur utilisation; - L’effort manuel pour mettre en mouvement le vantail ne doit pas excéder 225N pour les portes et portails en usage privé, et 390N pour les portes et portails à usage industriel et commercial (valeurs indiquées au paragraphe 5.3.5 de la norme EN 12453). ATTENTION: En débloquant les KING PLUS sous tension et en déplaçant les vantaux, les codeurs perdront le repère de la position des vantaux. Pour rétablir le fonctionnement du portail, il faudra couper le courant et le rétablir et donner une otre commande. SECURITES ELECTRIQUES Adapter les installation du parties electriques aux normes et lois en vigueur. Les modèles KING PLUS monophasés sont équipés d'un CODEUR pour la détection d'obstacles. En cas d'obstacle pendant la course, ces dispositifs de sécurité intervertissent immédiatement le mouvement en évitant ainsi tout risque d'écrasement ou d'entraînement (conformément aux normes européennes EN12453 et EN12445) sans devoir installer de bords sensibles. Il est conseillé d'utiliser les blocs moteurs électroniques : - KS2 ou T2 pour 1 ou 2 KING monophasés. Les tableaux T2 ne peuvent pas être utilisés pour gérer les CODEURS des KING PLUS monophasés. BRANCHEMENT DE L'ALIMENTATION Sur les versions KING monophasées, il faut relier les bornes 1-2-3 du connecteur respectivement aux bornes V-W-U du tableau de commande. BRANCHEMENT DU CODEUR (seulement versions PLUS) Les KING PLUS ont un CODEUR incorporé. Relier les bornes 1 / 2 / 3 du connecteur branché au CODEUR (5 V c.c.) aux bornes S / + / GND. ATTENTION ! Les câbles de raccordement des moteurs et encoders doivent être séparés et la longueur jusqu'à la centrale ne doit pas dépasser 15 m. La section du câble d'alimentation moteur doit être de 2,5 mm2. Pour l'encoder, utiliser une câble blindé de section 0,75 mm2 (Ex: ÖLFLEX-110 CH - Cod. ACG2133). Il est impératif d'employer un câble blindé pour l'encoder afin de garantir le bon fonctionnement du coffret de commande. Pour les accessoires utiliser une section de câble de 0,75 mm2 REGLAGE DE LA FORCE Sur les versions KING monophasées, utiliser un coffret électronique de type KS2 ou T2 équipé d'un régulateur de force électronique. Sur les versions KING PLUS monophasées, le dispositif de sécurité est équipé d'un CODEUR pour déterminer la détection d'un obstacle et pour gérer ce type de dispositif de sécurité, il est conseillé d'utiliser le coffret électronique KS2. ENTRETIEN Effectuer seulement par personnel specialisé après avoir coupé l'alimentation. Tous les ans, graisser les gonds et contrôler la force de poussée exercée par le motoréducteur sur le portail. Tous les deux ans, il est conseillé de lubrifier la vis-mère avec une graisse à base de silicone. 17 17 F 12 13 14

Pour les branchements et les données techniques des accessoires, se conformer aux livrets

d’instruction correspondants. KS2 (pour KING PLUS - KING L PLUS) code ABKS105 => 230V code ABKS104 => 120V Autoapprentissage de course et temps Fermeture automatique Pré-clignotement Vitesse lente à l’approche de la fermeture Réglage de la force Commande radio automatique à pas Commande simple automatique à pas Commandes directionnelles ouvrir et fermer (avec gestion horloge) Coup de bélier serrure électrique Commande de stop Gestion des moteurs avec encoder Gestion photocellules Gestion clignotant Gestion cordon de securité Sélecteur à clef Buzzer Serrure électrique T2 (pour KING - KING L - KING ICE - KING FAST) code ABT2000 => CRX 230/50-60HZ code ABT2001 => 230/50-60HZ code ABT2002 => CRX 120/60HZ code ABT2003 => 120/60HZ Auto-apprentissage course et temps Ouverture piétonne Fermeture automatique totale et piétonne Pré-clignotement Ralentissement réglable en approche Réglage de la force Commande radio automatique ou pas à pas Commande simple automatique ou pas à pas Coup de bélier serrure électrique Récepteur radio incorporé Gestion photocellules Gestion clignotant Gestion cordon de securité Autotest cordons de sécurité comme requis par la norme EN12453 Sélecteur à clef Buzzer Serrure électrique

CARTE EXPANDER PLEX POUR KS2

COMME EXPANDER AVEC EN PLUS: - AUTOTEST POUR 4 PHOTOCELLULES - AUTOTEST CORDON DE SÉCURITÉ * PAS POUR EXPANDER PLEX code ACG5472 CARTE EXPANDER POUR KS2 !! ENGAGER LA CARTE EXP EN CAS DE COUPURE DE COURANT !! - OUVERTURE PIÉTON - FERMETURE AUTOMATIQUE PIÉTON - GESTION CORDONS DE SÉCURITÉ - ALIMENTATION POUR ACCESSOIRES EN 24VAC - GESTION FEU ROUGE/VERT - GESTION ÉCLAIRAGE DE ZONE - FERMETURE ANTICIPÉE APRÈS PASSAGE DEVANT LES PHOTOCELLULES* code ACG5470 D5 D4 D3 D2 CABLE BLINDE POUR KS2 Il est impératif d'employer un câble blindé pour l'encoder afin de garantir le bon fonctionnement du coffret de commande. Le câble de l’ENCODER doit avoir à une extrémité, le blindage relié à la terre (pas à la borne GND), et à l’autre extrémité le blindage ne doit pas être connecté à rien (fil libre). code ACG2133 BLOCK BLOCK - SÉLECTEUR À CLÉ MURAL code ACG1053 BLOCK - SÉLECTEUR À CLÉ ENCASTRER code ACG1048 RADIORÉCEPTEURS AUTO-APPRENDISSAGE RX91/A quartzée embrochable code ACG5005 RX91/A quartzée avec bornes à visser code ACG5004 RX433/A superhétérodyne embrochable code ACG5055 RX433/A superhétérodyne avec bornes à visser code ACG5056 RX433/A 2CH superhétérodyne à deux canaux embrochable code ACG5051 RX433/A 2CH superhétérodyne à deux canaux avec bornes à visser code ACG5052 433 code ACG6081 433 code ACG6082 91 code ACG7025 91 code ACG7026 code ACG6093 MOON 433 - MOON 91 MOON CLONE EMETTEUR RADIO MOON POUSSOIR FLAT Pour raccorder un moteur en direct code ACG2012 Pour raccorder à une carte électronique code ACG2013

PAIRE DE POTEAUX POUR PHOTOCELLULES FIT SLIM

code ACG8065 FIT SLIM PHOTOCELLULES MURALES code ACG8032 Les photocellules FIT SLIM ont la fonction de synchronisme dans le courant à C.A. et les gammes de 20m. Plusieurs paires sont appliqués, rapprochés les uns des autres grâce au circuit synchronisé. Ajouter le TRANSMETTEUR TX SLIM SYNCRO code ACG8029 s’il existe plus de deux paires de photocellules (jusqu'à 4). SPARK Afin d'optimaliser les performances des appareils suscités, il est indispensable d'installer une antenne accordée sur la fréquence du radiorécepteur installé. N.B. Veiller à ce que le fil central du câble n'entre pas en contact avec l'enveloppe extérieure en cuivre; dans le cas contraire, le fonctionnement de l'antenne serait nul. L’antenne doit être installée de façon perpendiculaire et être en vue de la télécommande. ANTENNE SPARK 91 code ACG5454 ANTENNE SPARK 433 code ACG5452 FEU CLIGNOTANT SPARK avec carte intermittente incorporée code ACG7059 VERROU MECANIQUE Pour le verrouillage au sol du premier vantail code ACG5000 F

1 - KING operator

2 - Tuned aerial 3 - Flashing lamp 4 - Key selector 5 - Photoelectric cells (external) TECHNICAL FEATURES KING is a series of linear irreversible operators, suitable for opening gates with a leaf length of up to 4,5 metres (Fig.1). The KING operators use mechanical stoppers, thus avoiding the need for electrical limit switches. On reaching the travel limit, the motor continues to operate for a few seconds, until the timer of the control unit (or the ENCODER in the PLUS version) cuts in. † ‚ ‚ † ƒ „ Measurements in mm KING L L=1020 L1=945 L2=470 KING L=888 L1=815 L2=340 1 S / Encod M 2 + 3 GND * ONLY KING PLUS * 1 V 2 W 3 U Encoder 1 G B SYSTEM LAY-OUT TECHNICAL DATA Max. leaf length Max. leaf weight Max. travel Average opening time Operating speed Thrust force EEC Power supply Motor capacity Power absorbed Capacitor Power supply Motor capacity Power absorbed Capacitor Power supply Motor capacity Power absorbed Capacitor No. normative cycles 230V No. normative cycles 220V No. normative cycles 120V No. of daily operations suggested Service No. guaranteed consecutive cycles Grease Weight of electroreducer Noise Volume Operating Temperature Protection m 3,5* 4,5* kg 400 500 mm 345** 475** s. 14÷27 29÷38 m/s. 0,0125 N 1800 230V~ 50Hz W 290 A 1,2 µF 10 220V~ 60Hz W 225 A 1,04 µF 8 120V~ 60Hz W 255 A 2,3 µF 35 17 - 14s/2s 10 - 33s/2s 31 - 14s/2s 20 - 33s/2s 29 - 14s/2s 11 - 35s/2s 150 60% 20/14s 15/33s Bechem - RHUS 550 kg 10 14 db <70 m3 0,0184 0,0211 °C -10 ÷ +55°C IP 447 KING KING L ** With incorporated mechanical stop that cuts in during opening. - If the mechanical stop is used during closing (optional), the maximum travel is reduced by 50 mm.

The leaf must be fixed firmily on the hinges to the pillars, must not be

flexible during the movement and must move without frictions. Before the installation of KING, verify all dimensions etc. There's no need for any modification, if the gate is like that shown in Fig. 1. Gate features must be uniformed with the standards and laws in force. The gate can be automated only if it is in a good condition and its conditions comply with the EN 12604 norm. - The gate leaf does not have to have a pedestrian opening. In the opposite case it is necessary to take the appropriate steps, in accordance with EN 12453 norm (for instance; by preventing the operation of the motor when the pedestrian opening is opened, by installing a safety microswitch connected with the control panel). - No mechanical stop shall be on top of the gate, since mechanical stops are not safe enough. FIXING THE ACTUATOR ATTACHMENT TO THE COLUMN To obtain a correct movement of the leaf gate it is necessary to respect the measures (to see the TABLES of the measures). COLUMN ATTACHMENT FOR KING OPERATOR (code CCA1293 - CCA1294) If the column is in iron, the attack can be screwed directly using four metric screws M8. If the column is in concrete, the attack can be fixed with four expansion screws Ø 8 mm (Fig. 2-3). In the case you have a wall parallel with the open gate, you must provide a niche in which to place the operator. COLUMN ATTACHMENT FOR KING L OPERATOR (code CCA1370 - CCA1319) To obtain a correct movement of the leaf gate it is necessary to respect the measures. If there is an iron pillar you can weld the attachment directly. If there is a cement pillar, you can use the fixing plate as in Fig. 5 which is fastened with 4 Fischer-screws of Ø 8 mm. There is also the possibility to cement the attachment welding an anchor at its base Fig. 6. Naturally you have to respect predetermined fixing measures. Afterwards you must weld the other actuator's attachment to the gate (Fig. 8). In the case you have a wall parallel with the open gate, you must provide a niche in which to place the operator. 2 4 7 6 5 3 INSTALLATION KING COMMAND TYPE USE OF THE SHUTTER Skilled persons Skilled persons Unrestricted use (out of public area*) (public area) with manned operation A B non possibile with visible impulses C or E C or E C and D, or E (e.g. sensor) with not visible impulses C or E C and D, or E C and D, or E (e.g. remote controldevice) automatic C and D, or E C and D, or E C and D, or E * a typical example are those shutters which do not have access to any public way A: Command button with manned operation (that is, operating as long as activated), like code ACG2013 B: Key selector with manned operation, like code ACG1010 C: Adjustable power of the motor D: Safety edges, like code ACG3010 and/or other safety devices to keep thrust force within the limits of EN12453 regulation - Appendix A. E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1) Parts to install meeting the EN 12453 standard

FIXING THE OPERATOR ATTACHMENT TO THE GATE

(to see the TABLES of the measures). Weld the base at the right height (Fig. 8). Fix the KING and try several times to open and to close the gate, controlling that the screwcover does not touch the moving gate. 9 8 ANT Leaf attachment KING S2 S3 S1 Z Y X Z Y X Z Y X COL Column attachment KING ANT KING L Leaf attachment KING L A B C D

* In the case of leaf longer than 2,5 metres, an electric lock must be fitted to ensure

efficient closing. If the pillar is too large, and it is not possible to adjust the actuator respecting the measure (B), you must make a niche in the pillar or you have to move the gate to the edge of the pillar. ANT Leaf attachment S1 Z Y X COL Column attachment KING RESPECT THE MEASURES FOR A CORRECT INSTALLATION MECHANICAL STOP - OPTIONAL Code ACG8089 Optional mechanical stop to stop closing, if the gate is not fitted with a floor stop (Fig. 11). RESPECT THE MEASURES WITH 2 MECHANICAL STOPPERS G B S3-Y S3-X S1-Z S2-Y S2-Y - - S1-Z S2-Y S1-Y - - - S3-Y S3-X S1-Z S1-Y - - COL COL COL S1-Z S2-Y S1-Y - - 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 90° 45 100 100 775 90 14 A 45 110 110 775 90 18 A 70 140 110 775 115 20 B 70 160 140 775 115 25 B 60 170 170 905 120 23 C 100 190 180 905 120 25 C L Min.÷Max α A max T sec B C D E ANT ANT 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 110° 20 90 140 775 90 20 A 100 130 775 90 21 A 110 140 775 115 24 B 130 140 905 120 18 C 130 150 905 120 19 C L Min.÷Max α A max T sec B C D E KING KING KING KING KING L KING L KING KING KING KING L KING L 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 4,01*÷4,50* 90° 45 100 100 815 90 14 A 45 110 110 815 90 18 A 70 140 110 815 90 20 A 90 170 140 815 115 25 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min.÷Max α A max T sec B C D E 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 110° 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min.÷Max α A max T sec B C D E ANT ANT KING KING KING KING KING KING L KING L KING KING KING KING L KING L KING L COL B A C D ANT KING L Leaf attachment KING L

MECHANICAL STOPPER ADJUSTMENT

To adjust the stoppers you have to follow the scheme (Fig. 12). To set the opening limit it’s enough to fix the stopper (A) in the needed position by tightening the 8mA screw with a n.13 key. To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) ) in the needed position and tighten it as for stopper (A). EMERGENCY RELEASE To move the gate manually it is necessary to release the operator inserting the special key and turning it 3 times in the anti-clockwise sense (Fig. 14). In order to carry out the manual operation of the gate leaf the followings must be checked: - That the gate is endowed with appropriate handles; - That these appropriate handles are placed so to avoid safety risks for the operator; - That the physical effort necessary to move the gate leaf should not be higher than 225 N, for doors/gates for private dwellings, and, 390N for doors/gates for commercial and industrial sites ( values indicated in 5.3.5 of the EN 12453 norm). ATTENTION: If you release KING PLUS with power supply on and move the leaves, the encoder will lose the position of the leaves. To reset the correct operations of the gate you have to re-engage the motors, cut-off and turn on the power supply and give a command. ELECTRICAL SAFETY DEVICES The installation must be installed according to the current regulations and laws. Single-phase KING PLUS models are equipped with ENCODERS for obstacle detection. If an obstacle is encountered during movement these actuators go immediately into reverse so as to prevent any danger of crushing or dragging (as required by European regulations EN12453 and EN12445) without having to fit edge sensors. It is recommended that the following electronic control units be used: - KS2 or T2 for 1 or 2 single-phase KING. T2 control panel cannot be used to control single-phase KING PLUS units with ENCODERS. For connections and technical data of accessories refer to the appropriate booklets. CONNECTION TO THE POWER SUPPLY In single-phase KING units, terminals 1-2-3 of the motor connector must be connected respectively to terminals V-W-U of the control panel. CONNECTION TO THE ENCODER (PLUS versions only) KING PLUS units are equipped with a built-in ENCODER. Connect terminals 1 / 2 / 3 of the connector connected to ENCODER (5Vdc) to terminals S / + / GND. WARNING! The length of connection cables from the motors to the control panel unit must not exceed 15 m. The wire section of the motor power supply must be 2.5 mm2, whilst that of the accessories must be 0,75 mm2. As for the encorder it is very important to use a shielded wire with a section of 0,75 mm2 type ÖLFLEX-110 CH (Cod. ACG2133). It is compulsory to use shielded cable for the encoder in order to guarantee the correct operation of the control board. To ensure the correct functioning of the installation it is advisable to wire encoder and motor with separate cables. FORCE ADJUSTMENT Single-phase KING require a KS2 or a T2 electronic control panel, equipped with electronic force regulator. With single-phase KING PLUS , the operator is equipped with an ENCODER to detect an obstacle and the recommended control board for this type of actuator is the KS 2. MAINTENANCE To be undertaken only by specialized staff after disconnecting power supply. Lubricate the hinges and check the oil level and thrust force generated by the operator on the gate once a year. Lubricate the nut screw with silicon grease every two years. 25 25 G B 12 13 14

For the connections and the technical data of the optional equipments follow the relevant

handbooks. KS2 (for KING PLUS - KING L PLUS) code ABKS105 => 230V code ABKS104 => 120V Automatic travel and timing code learning system Automatic closure Pre-blinking Slow speed in closing approach Electronic adjustment of the force Radio command - step by step or automatic Single command - step by step or automatic Directional open and close commands (with timer control) Electric lock release operation Stop command Managing operators with encoder Management of the photocells Management of the blinker Management of the strips Key selector Buzzer Electric lock T2 (for KING - KING L - KING ICE - KING FAST) code ABT2000 => CRX 230/50-60HZ code ABT2001 => 230/50-60HZ code ABT2002 => CRX 120/60HZ code ABT2003 => 120/60HZ Automatic travel and timing code learning system Pedestrian opening command Pedestrian and Total automatic closure Pre-blinking Adjustable slow speed in approaching Electronic adjustment of the force Radio command - step by step or automatic Single command - step by step or automatic Electric lock release operation Built-in radio receiver 433MHz Management of the photocells Management of the blinker Management of the strips Safety strip autotest as required by EN12453 Key selector Buzzer Electric lock

follows from page 31

G B EXPANDER PLEX CARD FOR KS2 LIKE EXPANDER BOARD, BUT IN ADDITION WITH: - AUTOTEST OF 4 PHOTOCELLS - AUTOTEST STRIPS *NOT FOR EXPANDER PLEX code ACG5472 EXPANDER CARD FOR KS2 !! FEED THE EXP CARD IN WHEN POWER IS NOT SUPPLIED !! - PEDESTRIAN OPENING COMMAND - AUTOMATIC PEDESTRIAN CLOSING - MANAGEMENT OF THE SAFETY EDGE - 24VAC ACCESSORIES FEEDING - MANAGEMENT OF THE TRAFFIC LIGHT CONTR - MANAGEMENT OF THE COURTESY LIGHT - CLOSING COMMAND AFTER PASSING THROUGH THE PHOTOCELLS* code ACG5470 D5 D4 D3 D2 SHIELDED WIRE FOR KS2 It is compulsory to use shielded cable for the encoder in order to guarantee the correct operation of the control board. The screen of the ENCODER cable must be earth grounded at one end (not to the card GND), and at the opposite end the screen must be free (conductor not connected). code ACG2133 433 code ACG6081 433 code ACG6082 91 code ACG7025 91 code ACG7026 code ACG6093 MOON 433 - MOON 91 MOON CLONE RADIO TRANSMITTER MOON BLOCK KEY SELECTOR FOR WALL-INSTALLATION code ACG1053 KEY SELECTOR TO BUILD-IN code ACG1048 CODE LEARNIG SYSTEM RADIORECEIVERS RX91/A quarzata and coupling code ACG5005 RX91/A quarzata and terminal board code ACG5004 RX433/A super eterodyne and coupling code ACG5055 RX433/A super eterodyne and terminal board code ACG5056 RX433/A 2CH super eterodyne, 2 channel and coupling code ACG5051 RX433/A 2CH super eterodyne, 2 channel and terminal board code ACG5052 PUSH-BUTTON FLAT Connection to motor code ACG2012 Connection to control panel code ACG2013

PAIR OF COLUMNS FOR FIT SLIM

code ACG8065 FIT SLIM PHOTOCELLS for the wall-installation code ACG8032 FIT SLIM photocells have synchronism function in AC current and ranges of 20 m. You can fit many couples close together thanks to the synchronising circuit. Add the SYNCRO TRANSMITTER TX SLIM SYNCRO code ACG8029 for more than 2 photocells couples (up to 4). SPARK In order to make the systems mentioned above give the best performances, you need to install an antenna tuned on the frequency of the radio receiver installed. N.B. Pay attention to not let the central wire of the cable to came Into contact with the external copper sheath, since this would prevent the antenna from working. Install the antenna vertically and in such a way the remote control can reach it. SPARK ANTENNA 91 code ACG5454 SPARK ANTENNA 433 code ACG5452 SPARK BLINKER WITH IN-BUILT INTERMITTENT CARD code ACG7059 MECHANICAL BOLT For 2-leaf gates to latch closed gate to the ground. code ACG5000 G B

1 - E-Torantrieb KING

2 - Antenne 3 - Blinkleuchte 4 -Schlusselschalter 5 - Photozelle Toraussenseitig TECHNISCHE EIGENSCHAFTEN KING ist eine Serie von selbsthemmenden Antrieben mit elektrischer Rutschkupplung die für Drehtore mit den Torflügen bis zu 4,5 m verwendbar sind (Fig. 1). Nach Erreichen des Endanschlags bleibt der Motor noch einige Sekunden lang bis zum Ausschalten durch die Zeitschaltuhr der Steuerzentrale (oder durch den ENCODER bei dem Bautyp PLUS) in Betrieb. † ‚ ‚ † ƒ „ Abmessungen in mm KING L L=1020 L1=945 L2=470 KING L=888 L1=815 L2=340 1 S / Encod M 2 + 3 GND * NUR KING PLUS * 1 V 2 W 3 U Encoder 1 D ANLAGEN LAY-OUT TECHNISCHE EIGENSCHAFTEN Max. Torflügelweite Max. Torgewicht Max. Hub Öffnungszeit ca. Laufgeschwindigkeit Max. Schubkraft Stromspannung und Frequenz CEE Motorleistung Stromaufnahme Kondensator Normative Zyklen Max. tägliche Zyklen Service Garantierte kontinuierliche Zyklen Schmiere Motorgewicht Geräusch Volumen Betriebstemperatur Schutzartklasse m 3,5* 4,5* kg 400 500 mm 345** 475** s. 14÷27 29÷38 m/s. 0,0125 N 1800 230V~ 50Hz W 290 A 1,2 µF 10 n° 17 - 14s/2s 10 - 33s/2s n° 150 60% n° 20/14s 15/33s Bechem - RHUS 550 kg 10 14 db <70 m3 0,0184 0,0211 °C -10 ÷ +55°C IP 447 ** Mit eingebautem mechanischen Anschlag, der während der Öffnung anspricht. Wird auch der optionale mechanische Anschlag benutzt, der während des Schließens anspricht, so reduziert sich der maximale Zughub um 50 mm. KING KING L

PRÜFUNG VON DER MONTAGE

Das Flugeltor muß fest an der Angelpunkten der Träger fixiert sein, darf sich während der Bewegung nicht biegen und ohne Reibung bewegen. Bevor KING montiert wird ist es besser alle Hindernisse, die bei der Montage auftreten können festzustellen. Bei einem Tor wie in Abbildung 1 müssen keine Veränderungen vorgenommen werden. Es ist erforderlich, die Charakteristiken des Tors an die geltenden Normen und Gesetze anzupassen. Das Tor kann nur automatisch Angeschlossen werden, wenn es in einem einwandfreien Zustand ist und der EN12604 entspricht. - Das Tor welches keine Gehfluegelfunktion hat,in diesem Fall ist es erforderlich das Tor mit der norm EN12453 in Einklang zu bringen(z.B. das in Bewegung setzen des Motors per Handsender, wenn der Gehfluegel geoeffnet ist. Das zu vehindern koennen sie einen Endschalter anschliessen der beim oeffnen des Gehfluegel andere automatischen funktionen ausser Kraft setzt). - Es dürfen keine mechanischen Anschläge über dem Tor vorhanden sein, da diese nicht ausreichend sicher sind. BEFESTIGUNG DES ANTRIEBES AUF DIE SÄULE Um KING zu montieren, müssen einige Maße beachtet werden, damit eine richtige Bewegung des Torflügels gegeben ist. (die TABELLEN der Masse sehen). HALTERUNG PFEILER FÜR OPERATOR KING (code CCA1293 - CCA1294) Wenn die Spalte im Eisen ist, kann der Angriff geschraubt werden direkt mit vier Schrauben M8. Wenn die Spalte im Beton ist, kann der Angriff mit vier dem Expansion Schrauben Ø 8 Millimeter geregelt werden (Fig. 2-3). Im Falle, es existiert eine Maurer, die parallel zum Tor im offenen Zustand läuft, ist es notwendig eine Wandvertiefung zu schaffen, um Platz für den Motorantrieb zu haben. HALTERUNG PFEILER FÜR OPERATOR KING (code CCA1370 - CCA1319) Falls der Torträger aus Eisen ist, kann man die Verankerung direkt anschweißen. Bei einem Torträger aus Zement bedient man sich einer Platte wie in Abb. 5, die man mit 4 Fischer-Dübel Ø 8 mm anschraubt. Man kann die Verankerung auch in den Träger einmauern. Dazu schweißt man am Sockel einem Haken an (wie in Abb. 6). Nacher wird auf den Torflügel der Anschluß für die Förderschnecke geschweißt. Die vorgesehenen Maße sind naturlich zu beachten (Abb. 7). Im Falle, es existiert eine Maurer, die parallel zum Tor im offenen Zustand läuft, ist es notwendig eine Wandvertiefung zu schaffen, um Platz für den Motorantrieb zu haben. 2 4 7 6 5 3 D INSTALLATION KING STEUERUNGSSYSTEM ANWENDUNG DER SCHLIESSUNG Fachpersonen Fachpersonen Grenzlose (außer einem öffentlichen Platz*) (öffentlicher Platz) Anwendung mit Totmannschaltung A B nicht möglich mit sichtbaren C o E C o E C e D, o E (z.B. Sensor) mit nicht sichtbaren C o E C e D, o E C e D, o E Impulsen (Fernsender) automatisch * ein Musterbeispiel dafür sind jene Türe, die keine Zufahrt zu einem öffentlichen Weg haben A: Betriebstaste mit Totmannschaltung (das heißt, aktivieren sie eine Funktion, solange man sie gedrückt hält), wie Code ACG2013 B: Schlüsselselektor mit Totmannschaltung, wie Code ACG1010 C: Justierbare Kraft des Motors D: Kontaktleiste, wie Code ACG3010 und /oder andere Sicherheitseinrichtungen muessen mit den Norm EN12453 uebereinstimmen (Anhang A). E: Photozelle, wie Code ACG8026 (Jede 60÷70cm für die ganze Höhe der Spalte des Gatters bis zu einem Maximum von 2,5m anwenden - EN 12445 Punkt 7.3.2.1) Komponenten zur Installation nach der Norm EN1253

BEFESTIGUNG DES ANTRIEBES AUF DAS TORFÜGEL

(die TABELLEN der Masse sehen). Schweißen Sie den Sockel in der richtigen Höhe (Abb. 8) an. Befestigen Sie KING und versuchen Sie mehrere Male zu öffnen und zu schließen, Kontrollieren Sie dabei, daß das Profil der Schraubenabdeckung das Tor in Bewegung nicht berührt. 9 8 ANT Halterung Torfluegel KING S2 S3 S1 Z Y X Z Y X Z Y X COL Halterung Pfeiler KING ANT KING L Halterung Torfluegel KING L folgt von der Seite 39 D A B C D

* Ab Flügelmaß von 2,5 Metern muß ein elektrisches Schloß zur Gewährleistung einer

wirkungsvollen Schließung angebracht werden. Falls der Torantrieb nicht mit dem richtigen Maß (B) montiert werden kann, da der Torträger zu breit ist, muß man in der Säule eine Wandvertiefung schaffen oder das Tor an den Rand versetzen. ANT Leaf attachment S1 Z Y X COL Column attachment KING DIE KORREKTEN ABMESSUNGEN UND INSTALLATION MIT EINEM STOPPER IM ANTRIEB MECHANISCHE SPERRVORRICHTUNG - OPTIONEN Code ACG8089 Als Zubehör eine mechanische Sperrvorrichtung, die das Gittertor beim Schließen anhält, falls keine Feststellvorrichtung auf dem Boden vorhanden ist (Abb. 11). FÜR EINE KORREKTE INSTALLATION MIT ZWEI MECHANISCHE SPERRVORRICHTUNG D S3-Y S3-X S1-Z S2-Y S2-Y - - S1-Z S2-Y S1-Y - - - S3-Y S3-X S1-Z S1-Y - - COL COL COL S1-Z S2-Y S1-Y - - 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 90° 45 100 100 775 90 14 A 45 110 110 775 90 18 A 70 140 110 775 115 20 B 70 160 140 775 115 25 B 60 170 170 905 120 23 C 100 190 180 905 120 25 C L Min.÷Max α A max T sec B C D E ANT ANT 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 110° 20 90 140 775 90 20 A 100 130 775 90 21 A 110 140 775 115 24 B 130 140 905 120 18 C 130 150 905 120 19 C L Min.÷Max α A max T sec B C D E KING KING KING KING KING L KING L KING KING KING KING L KING L 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 4,01*÷4,50* 90° 45 100 100 815 90 14 A 45 110 110 815 90 18 A 70 140 110 815 90 20 A 90 170 140 815 115 25 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min.÷Max α A max T sec B C D E 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 110° 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min.÷Max α A max T sec B C D E ANT ANT KING KING KING KING KING KING L KING L KING KING KING KING L KING L KING L COL B A C D ANT KING L Leaf attachment KING L

EINSTELLUNG DES MECHANISCHEN ENDSCHALTERS

Um die Endschalter einzustellen, müssen Sie wie in der Abbildung handeln (Abb. 12). Um die erwünschte Offnungsweite einzustellen, genüngt es, die Endschalter (A) zu verstellen und sie mit Hilfe eines Imbusschlüßels an der Mutterschraube festzuziehen. Um die erwünschte Schliessweite einzustellen, müssen Sie die Endschalter (B) verstellen. NOTENTRIEGELUNG Um das Tor des Modells KING manuell zu bedienen, müßen Sie den dafür vorgesehenen Schlußel in das Schloß stecken und ihn dreimal entgegen dem Uhrzeigersinn drehen (Abb. 14). Um das Tor manuell richtig zu pruefen muessen folgende Punkte beachtet werden: - Das Tor muss einen geeigneten Griff haben. - Dieser Griff muss so angebracht sein das er kein Risiko ist beim Test. - Daß die physische notwendige Kraft um das Tor-Blatt zu bewegen nicht höher als 225N ist, für Tore bei privaten Wohnungen, und 390N für Tore für kommerzielle und industrielle Situationen (Werte nach 5.3.5 vom EN 12453 Norm). ACHTUNG: Erfolgt die Entsperrung der KING PLUS bei anliegender Spannung und werden die Torflügel bewegt, verlieren die Encoder die Bezugspunkte der Torflügelposition. Um die korrekte Arbeitsweise des Gittertors wieder herzustellen, die Stromzufuhr zu der elektronischen Steuertafel aus- und wieder einschalten und einen neuen Befehl geben. ELEKTRISCHE SICHERHEITEN Die Installation muß nach den aktuellen Gesetznormen installiert werden. Die Einphasen-Modelle KING PLUS sind mit einem ENCODER für die Erfassung von Hindernissen ausgestattet. Sobald während des Laufes ein Hindernis erfasst wird, kehrt der Encoder die Bewegung um und vermeidet so die Gefahr von Quetschungen oder Mitreißen (entsprechend den europäischen Richtlinien EN 12453 und EN 12445), ohne berührungsempfindliche Kanten einbauen zu müssen. Es wird die Verwendung folgender elektronischer Steuertafeln empfohlen: - KS2 oder T2 für KING mit 1 oder 2 Einphasenmotoren. Die Steuerung T2 sind nicht für die Steuerung der ENCODER der Einphasen-Modelle KING PLUS verwendbar. Für die Anschlüsse und technische Daten der Zubehörteilen verweisen wir auf die entsprechenden Bedienungshandbücher. STROMANSCHLUSS Bei den KING Einphasen-Modellen sind die Klemmen 1-2-3 des Verbinders mit den Klemmen V-W-U der Steuertafel zu verbinden. ENCODERANSCHLUSS (nur Modelle PLUS) Die Modelle KING PLUS sind mit einem eingebauten ENCODER ausgerüstet. Die Klemmen 1 / 2 / 3 des an den ENCODER (5Vdc) angeschlossenen Verbinders an die Klemmen S / + / GND anschließen. ACHTUNG ! Die Verbindungskabel vom Motor zum Steuergerät dürfen nicht länger als 15 m sein. Der Querschnitt der Zuleitungen zum Motor muss mindestens 2,5 mm2 betragen. Der Querschnitt der Zuleitung für Zusatzgeräte muss mindestens 0,75 mm2 betragen. Der Querschnitt der Zuleitung für den Encoder muss mindestens 0,75mm2 haben, und Sie muss abgeschirmt sein (Cod.ACG2133). Der Einsatz von abgeschirmtem Kabel ist ratsam, da es sonst zu Fehlern im Programmablauf kommen kann. Um ein korrektes arbeiten des Encoders zu garantieren, beachten Sie die Installation der Anschlusskabel. EINSTELLUNG DER KRAFT Die KING Einphasen-Modelle benötigen eine elektronische Steuerung des Typs KS2 oder T2, die mit einem Schubkraftregler ausgerüstet sind. Die Einphasen-Modelle KING PLUS sind mit einem ENCODER zur Erfassung von Hindernissen ausgestattet und bei Verwendung dieser Komponenten wird der Einbau der elektronischen Steuertafel KS2. WARTUNG Die Wartungsarbeit nur durch spezialiesierten Fachleuten nach der Ausschliessung der Spannung auszuführen. Einmal jährlich sind die Angelzapfen zu schmieren und die vom Getriebemotor ausgeübte Antriebskraft. Es wird empfohlen, alle zwei Jahre die Schnecke mit Silikonfett zu schmieren. 33 33 A - VERBINDUNGEN D 12 13 14

OPTIONEN - Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die

entsprechenden Betriebsanleitungen. KS2 (für KING PLUS - KING L PLUS) Kode ABKS105 => 230V Kode ABKS104 => 120V Automatisches codelernen des Hubs und der Zeiten Automatisches Schliessen Vorblinken Langsame Geschwindigkeit in der Annäherung Elektronische Kupplung Automatishcer - oder schrittfunkbefehl Automatischer - oder schritteinzelbefehl Direktionsbefehle für die Öffnung und für das schliessen Haltebefehl (mit Uhrbetrieb) Elektrischer Verriegelung Freigabebetrieb Stoppen Sie Befehl Sicherheitsencoder Überwachung den Fotozellen Überwachung der Blinklicht Überwachung den Kontaktleiste Schlüsselschalter Buzzer Elektrische Verriegelung T2 (für KING - KING L - KING ICE - KING FAST) Kode ABT2000 => CRX 230/50-60HZ Kode ABT2001 => 230/50-60HZ Kode ABT2002 => CRX 120/60HZ Kode ABT2003 => 120/60HZ Automatisches lernen des Weges-Hub und Zeiten Fußgängeröffnung Automatisches Fußgänger- und totalschliessen Vorblinken Sie können den Sanft-Stop beim schließen regeln Elektronische Kupplung Automatischer - oder Schrittfunkbefehl Automatischer - oder Stepp bei Stepp Einzellimpuls Elektrischer Verriegelung Freigabebetrieb Eingebautes Radiogerät 433MHz Überwachung den Fotozellen Überwachung der Blinklicht Überwachung den Kontaktleiste Selbstkontrolle der Sicherheitsrippen, gemäß Vorschrift der Norm EN12453 Schlüsselschalter Buzzer Elektrische Verriegelung

KARTE EXPANDER PLEX FÜR KS2

WIE EXPANDER ABER DAZU: - AUTOTEST VON VIER PHOTOZELLEN - RÜCKEN AUTOTEST *NICHT FÜR EXPANDER PLEX Kode ACG5472 KARTE EXPANDER FÜR KS2 !! DIE KARTE EXP NUR BEI ABGESCHALTETEM STROM EINSCHIEBEN !! - FUßGÄNGERÖFFNUNG - AUTOMATISCHE SCHLIESSUNG DER PERSONENÖFFNUNG - ADMINSTRATOR KONTAKT - VERSORGUNG FÜR ZUBEHÖRE MIT 24VAC - ÜBERWACHUNG DER AMPEL - ÜBERWACHUNG DES HOFLICHTES - SCHLIESSEN NACH DEM VORBEIGEHEN VOR DEN PHOTOZELLEN* Kode ACG5470 D5 D4 D3 D2 KABEL FÜR ENCODER FÜR KS2 Um das korrekte arbeiten des Encoder zu garantieren, ist es erforderlich, dass sie das richtige Kabel installieren. Die abschiermung des Kabels muss an die Erde angeschlossen werden, nicht am Kontakt(GND). Das andere Ende am Anschluss vom Motor bleibt frei (nicht angeschlossen). Kode ACG2133 BLOCK SCHLÜSSELWAHLSCHALTER FÜR DIE WAND Kode ACG1053 SCHLÜSSELWAHLSCHALTER ZUM EINBAU Kode ACG1048 SELBSTLERNEND FUNKEMPFGÄNGER RX91/A Quartz mit Steckkontakt Kode ACG5005 RX91/A Quartz mit Klemmbrett Kode ACG5004 RX433/A super eterodyne mit Steckkontakt Kode ACG5055 RX433/A super eterodyne mit Klemmbrett Kode ACG5056 RX433/A 2CH super eterodyne, 2 Kanäle mit Steckkontakt Kode ACG5051 RX433/A 2CH super eterodyne, 2 Kanäle mit Klemmbrett Kode ACG5052 433 Kode ACG6081 433 Kode ACG6082 91 Kode ACG7025 91 Kode ACG7026 Kode ACG6093 MOON 433 - MOON 91 MOON CLONE FERNSENDER MOON TASTER FLAT Verbindung zum motor Kode ACG2012 Verbindung zum elektronik Kode ACG2013

EIN PAAR FOTOZELLEN-STAENDER FÜR FIT SLIM

Kode ACG8065 FIT SLIM WANDFOTOZELLEN Kode ACG8032 FIT SLIM Fotozellen haben Synchronismusfunktion im Wechselstrom Strom und Strecken 20m. Dank einer Synchronisiereinrichtung sind mehrere sich gegenseitig annähernde Paare möglich. Bei mehr als 2 Fotozellenpaare (bis 4), den SENDER SYNCRO TX SLIM SYNCRO Kode ACG8029 SPARK Um die bestmöglichen Leistungen mit den o. g. Apparaten zu erhalten, muss eine auf die Frequenz des Funkempfängers abgestimmte Antenne montiert werden. Anmerkung: Besonders muss darauf geachtet werden, dass das Zentralkabel der Leitung nicht mit der externen Kupferumwicklung in Kontakt kommt, da dies die Funktion der Antenne außer Kraft setzt. Die Antenne muss senkrecht, von dem Fernbetätigungsgerät aus sichtbar montiert werden. ANTENNE SPARK 91 Kode ACG5454 ANTENNE SPARK 433 Kode ACG5452 BLINKER SPARK mit eingebauter wechselsignalkarte Kode ACG7059 MECHANISCHER RIEGEL Fuer zwei Fluegel, zur Verrieglung am Boden. Kode ACG5000 D

1 - Operador KING

2 - Antena de radio 3 - Intermitente 4 - Interruptor de llave 5 - Fotocélulas esternas CARACTERÍSTICAS TÉCNICAS KING es un tipo de operador irreversible, con una fricción eléctrica, utilizados para desplazar cancelas con batientes de hojas con una longitud de hasta 4,5 m (Fig. 1). La serie KING ha sido concebida para funcionar sin finales de carrera eléctricos sino sólo mecánicos. Al llegar al tope, el motor funciona todavía por algunos segundos, hasta que interviene el timer de funcionamiento de la central de mandos (o el ENCODER si es la versión PLUS). † ‚ ‚ † ƒ „ Mesures en mm KING L L=1020 L1=945 L2=470 KING L=888 L1=815 L2=340 1 S / Encod M 2 + 3 GND * SOLO KING PLUS * 1 V 2 W 3 U Encoder 1 E S DISPOSICIÒN DE LA INSTALACIÒN CARACTERÍSTICAS TÉCNICAS Longitud máxima de la anta Peso máx cancela Corrido max de arrastre Tiempo de abertura Velocidad de arrastre Fuerza max de empuje Alimentación e frequenza CEE Potencia motor Absorcion Condensatore Ciclos normativos Ciclos diarios sugeridos Servicio Ciclos garantizados Engrase Peso motor Nivel de ruido Volume Temperatura de trabajo Nivel de protección m 3,5* 4,5* kg 400 500 mm 345** 475** s. 14÷27 29÷38 m/s. 0,0125 N 1800 230V~ 50Hz W 290 A 1,2 µF 10 n° 17 - 14s/2s 10 - 33s/2s n° 150 60% n° 20/14s 15/33s Bechem - RHUS 550 kg 10 14 db <70 m3 0,0184 0,0211 °C -10 ÷ +55°C IP 447 ** Con el seguro mecánico incorporado que interviene durante la abertura. Si se utiliza también el seguro mecánico que interviene durante el cierre, opcional, la carrera máxima de remolque se reduce de 50 mm. KING KING L

CONTROLES DE LA PRE-INSTALACIÓN

La puerta de batiente debe fijarse sólidamente a las bisagras de las columnas y no debe balancearse durante el movimiento. Antes de proceder a la instalación de KING, es prudente verificar todos los espacios necesarios para emplazarlo. Si la cancela se presenta como en la Fig. 1, no hace falta efectuar ninguna modificación. N.B. Es obligatorio adecuar las características de la cancela a las normas y leyes vigentes. La puerta puede ser automatizada sólo si se encuentra en buen estado y responde a la norma EN 12604. - La puerta no tiene que tener puertas peatonales. De lo contrario se tendrán que tomar las oportunas precauciones de acuerdo con el punto 5.4.1 de la EN12453 (por ejemplo impedir el movimiento del motor cuando la puertecilla está abierta, gracias a un microinterruptor debidamente conectado a la central). - No hay que generar puntos donde se pueda quedar atrapado (por ejemplo entre la puerta de la cancela y la verja). Las columnas de la verja tienen que llevar en su parte superior unas guías anti-descarrilamiento para evitar desenganches involuntarios. - No tiene que haber topes mecánicos por encima de la verja porque no son suficientemente seguros. FIJACIÓN DEL ENGANCHE DEL MOTOR A LA COLUMNA Instalando el KING es necesario respetar algunas medidas par obtener un correcto desplazamiento de la puerta (véase los CUADROS de las medidas). ENGANCHE COLUMNA PARA KING (cód. CCA1293 - CCA1294) Si la columna es de hierro, el ataque se puede atornillar directamente usando cuatro tornillos M8. Si la columna es de concreto, el ataque se puede fijar con cuatro tornillos de expansión de Ø 8 mm (fig. 2-3). En el caso de que la pared se encuentre paralela a la cancela cuando ésta se encuentra abierta, puede que sea necesario crear una encajadura para el operador. ENGANCHE COLUMNA PARA KING L (cód. CCA1370 - CCA1319) Si la columna es de hierro se le puede soldar directamente el enganche. Si la columna es de cemento se utiliza una plancha como en la Fig. 5 y se la fija con cuatro tornillos de expansión de Ø 8 mm. Otra alternativa es la de encementar el enganche en la columna soldándole en la base una grapa como en la Fig. 6. Continuando con la instalación se tiene que soldar en la puerta el enganche para el arrastre de la cancela, observando naturalmente las cuotas previstas (Fig. 7). En el caso de que la pared se encuentre paralela a la cancela cuando ésta se encuentra abierta, puede que sea necesario crear una encajadura para el operador. 2 4 7 6 5 3 TYPO DE MANDO USO DEL CIERRE Personas expertas Personas expertas Uso ilimitado (fuera de un área pública*) (área pública) en presencia de alguien A B non posivel con impulsos a la vista C o E C o E C e D, o E (ej. sensor) con impulso no a la vista C o E C e D, o E C e D, o E (ej. telemando) automatico C e D, o E C e D, o E C e D, o E *un ejemplo típico son los cierres que no dan a la calle. A: Pulsador de mando en presencia de alguien, (es decir con acción mantenida), como cód. ACG2013. B: Interruptor de llave en presencia de alguien, como cód. ACG1010. C: Regulacion de la fuerza del motor. D: Nervaduras como cód. ACG3010 y / o otros dispositivos que limitan las fuerzas entre limites de las normas EN 12453 - Appendix A. E: Fotocélulas, como cód. ACG8026 (Da applicare cada 60÷70cm por toda la altura de la puerta hasta un máximo de 2,5m (EN 12445 punto 7.3.2.1). Componentes a instalar según la norma EN12453 E S INSTALACIÓN KING

FIJACIÓN DEL ENGANCHE DEL MOTOR A LA CANCELA

(véase los CUADROS de las medidas). Soldar el enganche a la altura justa (Fig. 8). Instalar el KING probando a cerrar y abrir controlando que el perfil cubretornillos no roce la cancela en movimiento. 9 8 ANT Enganche cancela KING S2 S3 S1 Z Y X Z Y X Z Y X COL Enganche columna KING ANT KING L Enganche cancela KING L E S A B C D

* Además, a los 2,5 metros de longitud de la puerta tiene que colocarse una

electrocerradura para asegurarse un eficaz cierre. En el caso de que el pilar fuera demasiado ancho y no fuese posible instalar el electroreductor respetando la medida (B), es indispensable crear una encajadura en el pilar o desplazar la cancela hacia la esquina. ANT Enganche cancela S1 Z Y X COL Enganche columna KING MEDIDAS A RESPETAR PARA UNA INSTALACIÓN CORRECTA SEGURO MECÁNICO Cód. ACG8089 El seguro mecánico opcional para detener el cierre en caso de que la cancela no tenga un seguro de tierra (Fig. 11). MEDIDAS A RESPETAR CON SEGURO MECÁNICO E S S3-Y S3-X S1-Z S2-Y S2-Y - - S1-Z S2-Y S1-Y - - - S3-Y S3-X S1-Z S1-Y - - COL COL COL S1-Z S2-Y S1-Y - - 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 90° 45 100 100 775 90 14 A 45 110 110 775 90 18 A 70 140 110 775 115 20 B 70 160 140 775 115 25 B 60 170 170 905 120 23 C 100 190 180 905 120 25 C L Min.÷Max α A max T sec B C D E ANT ANT 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 110° 20 90 140 775 90 20 A 100 130 775 90 21 A 110 140 775 115 24 B 130 140 905 120 18 C 130 150 905 120 19 C L Min.÷Max α A max T sec B C D E KING KING KING KING KING L KING L KING KING KING KING L KING L 1÷1,80 1,81÷2,20 2,21÷2,50 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 4,01*÷4,50* 90° 45 100 100 815 90 14 A 45 110 110 815 90 18 A 70 140 110 815 90 20 A 90 170 140 815 115 25 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min.÷Max α A max T sec B C D E 1÷1,80 1,81÷2,20 2,21÷2,50* 2,51*÷3,00* 3,01*÷3,50* 3,51*÷4,00* 110° 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min.÷Max α A max T sec B C D E ANT ANT KING KING KING KING KING KING L KING L KING KING KING KING L KING L KING L COL B A C D ANT KING L Enganche cancela KING L

AJUSTE DE LOS FINALES DE CARRERA MECÁNICOS

Para posicionar los seguros se tiene que operar como en el esquema (Fig. 12). Para poder obtener la abertura deseada es suficiente mover el seguro (A) y bloquearlo con una llave fija n° 13. Para poder obtener el cierre deseado se tendrá que mover el seguro (B) (OPCIONAL) y bloquearlo con una llave fija n° 13. DESBLOQUEO DE URGENCIA En el caso de falta de corriente, para poder operar la cancela manualmente es suficiente introducir la respectiva llave y girarla 3 veces en sentido antihorario (Fig. 14). Para poder realizar en modo seguro el desplazamiento manual de la puerta hay que controlar que: - Las manillas de la puerta que se han proporcionado sean idóneas; - Estas manillas no estén posicionadas en modo de crear puntos de peligro durante su utilizo; - El esfuerzo manual para mover la puerta no debe superar los 225N para las cancelas colocadas en lugares privados y los 390N para las cancelas colocadas en sitios comerciales e industriales (valores indiacados en el punto 5.3.5 de la norma EN 12453). CUIDADO: Desbloqueando los KING PLUS con la corriente presente y moviendo las puertas, los encoders perderán las referencias de la posición de las puertas. Para restablecer el correcto funcionamiento de la cancela será necesario quitar la corriente y ejecutar un comando. PROTECCIONES ELÉCTRICAS Realizar la instalación de acuerdo a con las normas y las leyes vigentes. Los modelos KING PLUS monofásicos están dotados deI ENCODER para detectar obstáculos. En caso de obstáculos durante el desplazamiento estos operadores invierten inmediatamente el movimiento, evitando así el peligro de aplastamientos o arrastre como requerido por las normas europeas EN12453 y EN12445) sin tener que colocar bordes sensibles. Se aconseja el utilizo de centrales electrónicas de mando: - KS2 o T2 para 1 o 2 KING monofásico. No son utilizables paneles T2 para la la gestión del ENCODER de los KING PLUS monofásicos. Para las conecciones y los datos técnicos de los accesorios atenerse a los respectivos manuales. CONEXIÓN DE LA ALIMENTACIÓN En los KING monofásicos se tienen que conectar los terminales 1-2-3 del conector del motor respectivamente a los bornes V-W-U del panel de mando. CONEXIÓN DEL ENCODER (sólo versiones PLUS) Los KING PLUS están provistos de ENCODER incorporado. Conectar los terminales 1 / 2 / 3 del conector del ENCODER (5Vdc) a los bornes S / + / GND. CUIDADO! La longitud máx. de los cables de conexión desde el motor hasta la central tiene que ser de 15 m máx. con sección de hilo para la alimentación del motor de 2,5 mm2, para los accesorios, utilizar una sección de hilo de 0,75 mm2 y para el encoder usar un cable de conductores encerrados 3x0,75 mm2 tipo ÖLFLEX-110 CH (Cód. ACG2133). El cable de conductores encerrados para el encoder se debe utilizar obligatoriamente para garantizar el correcto funcionamiento del equipo. Para garantizar el correcto funcionamiento de la instalación se aconseja de hacer las conexiones del encoder y del motor instalando cables separados. REGULACIÓN DE LA FUERZA DE EMPUJE Para los KING monofásicos es necesario utilizar un panel electrónico tipo KS2 o T2 provisto de regulador de fuerza electrónico. Para los KING PLUS, el operador está provisto de un ENCODER para detectar un obstáculo y para gestir este tipo de operador se aconseja el utilizo de las centrales electrónicas de mando KS2. MANTENIMIENTO Estas operaciones deben ser efectuadas exclusivamente por personal especializado y con el motor desconectado de la alimentación eléctrica. Todos los años, engrasar las bisagras y controlar la fuerza de empuje ejercida por el motorreductor sobre la puerta. Cada dos años, se aconseja sustituir el aceite y lubricar la tuerca de husillo con grasa de silicona. 41 41 A - CONEXIÓN E S 12 13 14

OPCIONALES - Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos.

KS2 (para KING PLUS - KING L PLUS) cód. ABKS105 => 230V cód. ABKS104 => 120V Auto-aprendizaje recorrido y tiempos Cierre automático Pre-intermitencia Reducción de la velocidad en cierre Regulación de la fuerza Mando radio - automático o paso-a-paso Mando individual - automático o paso-a-paso Mandos direccionales abre (con gestión reloj) y cierra Golpe de desenganche de la cerradura eléctrica Mando de stop Gestiona encoder de detección obstáculo Administracion fotocélulas Administracion intermitencia Administracion costas Selector de llave Buzzer Cerradura eléctrica T2 (para KING - KING L - KING ICE - KING FAST) cód. ABT2000 => CRX 230/50-60HZ cód. ABT2001 => 230/50-60HZ cód. ABT2002 => CRX 120/60HZ cód. ABT2003 => 120/60HZ Autoaprendizaje carrera y tiempos Abertura peatonal Encierro automático peatonal y total Pre-intermitencia Moderación de velocidad en acercamiento regulable Regulación de la fuerza Gestión telemando - paso a paso o automática Gestión Botón único - paso a paso o automática Golpe de desenganche de la cerradura eléctrica Radio receptor 433MHz incorporado Administracion fotocélulas Administracion intermitencia Administracion costas Autotest costas de seguridad como requerido por la norma EN12453 Selector de llave Buzzer Cerradura eléctrica

TARJETA EXPANDER PLEX PARA KS2

COMO EL CUADRO EXPANDER, PERO CON ADEMÀS: - AUTOPRUEBA DE 4 FOTOCÉLULAS - AUTOPRUEBA DE PERFIL DE SEGURIDAD *NO PARA EXPANDER PLEX cód. ACG5472 TARJETA EXPANDER PARA KS2 !! INTRODUCIR LA TARJETA EXPANDER TRAS HABER CORTADO LA CORRIENTE !! - APERTURA PEATONAL - CIERRE AUTOMÁTICO PARA PEATONES - GESTIÓN DE BURLETE - ALIMENTACIÓN PARA ACCESORIOS A 24VAC - GESTIÓN SEMAFORO - GESTIÓN LUZ DE CORTESIA - CIERRE DESPUÉS DE PASAR POR DELANTE DE LAS FOTOCÉLULAS* cód. ACG5470 D5 D4 D3 D2 CABLE ENCODER PARA KS2 El cable de malla debe de ser obligatoriamente el especial par poder garantizar el funcionamiento del motor. El cable Encoder debe de tener la parte de malla conectada a tierra por una extremidad (NO a GND), y la otra extremidad no debe ser conectada a nada (hilo libre). cód. ACG2133 433 cód. ACG6081 433 cód. ACG6082 91 cód. ACG7025 91 cód. ACG7026 cód. ACG6093 MOON 433 - MOON 91 MOON CLONE TELEMANDO MOON BLOCK SELECTOR DE LLAVE DE PARED cód. ACG1053 SELECTOR DE LLAVE DE ENCAJAR cód. ACG1048 RADIO RECEPTOR CON AUTO APRENDIZAJE RX91/A de cuarzo con enchufe cód. ACG5005 RX91/A de cuarzo con regleta cód. ACG5004 RX433/A superheterodina enchufable cód. ACG5055 RX433/A superheterodina con regleta (de conexión) cód. ACG5056 RX433/A 2CH superheterodina bi canal enchufable cód. ACG5051 RX433/A 2CH superheterodina bi canal con regleta cód. ACG5052 BOTONERA FLAT Conexión al motor cód. ACG2012 Conexión al panel de control cód. ACG2013

PAR DE COLUMNAS PARA FIT SLIM

cód. ACG8065 FIT SLIM FOTOCÉLULAS PARA PARED cód. ACG8032 Las fotocélulas FIT SLIM tienen una funciòn de sincronizaciòn en corriente alterna y portada de 20 metros. Pueden ser aplicadas màs parejas de fotocélulas cercanas gracias al circùito de sincronizaciòn. Añadir el TRANSMISOR TX SLIM SYNCRO cód. ACG8029 para sincronizar hasta 4 parejas de fotocélulas. SPARK Para obtener las mejores prestaciones de los citados aparatos, es necesario instalar una antena sintonizada con la frecuencia del radioreceptor. Importante: Controlar con atención que el hilo central del cable no esté en contacto con la protección de cobre externa. Esto impediría el funcionamiento de la antena. Instale la antena verticalmente y de tal manera el mando a distancia puede alcanzarla. ANTENA SPARK 91 cód. ACG5454 ANTENA SPARK 433 cód. ACG5452 INTERMITENTE SPARK con tarjeta intermitente incorporada cód. ACG7059 PESTILLO MECANICO Pestillo mecanico para cancelas de 2 hojas. cód. ACG5000 E S

25014 Castenedolo - Brescia - Italy

Via Matteotti, 162 Telefono ++39.030.2135811 Fax ++39.030.21358279 - 21358278 http://www.ribind.it - email: [email protected] DICHIARAZIONE DI CONFORMITÁ - DECLARATION OF COMPLIANCE DÉCLARATION DE CONFORMITÉ - ÜBEREINSTIMMNUGSERKLÄRUNG DECLARACIÓN DE CONFORMIDAD Dichiariamo sotto la nostra responsabilità che l’operatore KING è conforme alle seguenti norme e Direttive: L’opérateur KING se conforme aux normes suivantes: We declare under our responsibility that KING operator is conform to the following standards: Wir erklaeren das der KING den folgenden EN-Normen entspricht: Declaramos, bajo nuestra responsabilidad que el operador KING es conforme a la siguientes normas y disposiciones: Inoltre permette un’installazione a Norme - Permit, en plus, une installation selon les normes suivants You can also install according to the following rules - Desweiteren genehmigt es eine Installation der folgenden Normen Además permite una instalación según las Normas: Come richiesto dalle seguenti Direttive: - Comme demandé par les suivantes Directives: As requested by the following Directives: - Gemaß den folgenden Richtlinien: Tal y como requerido por las siguientes Disposiciones: Il presente prodotto non può funzionare in modo indipendente ed è destinato ad essere incorporato in un impianto costituito da ulteriori elementi. Rientra perciò nell’Art. 6 paragrafo 2 della Direttiva 2006/42/CE (Macchine) e successive modifiche, per cui segnaliamo il divieto di messa in servizio prima che l’impianto sia stato dichiarato conforme alle disposizioni della Direttiva. Le présent dispositif ne peut fonctionner de manière indépendante, étant prévu pour être intégré à une installation constituée d'autres éléments. Aussi rentre-t-il dans le champ d'application de l'art. 6, paragraphe 2 de la Directive machines 2006/42/CEE et de ses modifications successives. Sa mise en service est interdite avant que l'installation ait été déclarée conforme aux dispositions prévues par la Directive. . This product can not work alone and was designed to be fitted into a system made up of various other elements. Hence, it falls within Article 6, Paragraph 2 of the EC- Directive 2006/42 (Machines) and following modifications, to which respect we point out the ban on its putting into service before being found compliant with what is provided by the Directive. Dieses Produkt kann nicht allein funktionieren und wurde konstruiert, um in einen von anderen Bestandteilen zusammengesetzten System eingebaut zu werden. Das Produkt fällt deswegen unter Artikel 6, Paragraph 2 der EWG-Richtlinie 2006/42 (Maschinen) und folgenden. Este producto no puede funcionar de manera independiente y se tiene que incorporar en una instalación compuesta por otros elementos. Está incluido por lo tanto en el Art. 6 párrafo 2 de la Disposición 2006/42/CEE (Maquinaria) y sus siguientes modificaciones, por lo cual destacamos que está prohibido poner la instalación en marcha antes de que esté declarada conforme a la citada Disposición. Legal Representative EN 55014-1 2000 EN 55014-2 1997 EN 60335-1 2002 EN 61000-3-2 2000 EN 61000-3-3 1995 EN 61000-6-1 2001 EN 61000-6-2 1999 EN 61000-6-3 2001 EN 61000-6-4 2001 93/68/EEC 73/23/EEC 89/336/EEC 92/31/EC sigue de pàgina 58 EN12453 2000 EN 12445 2002 EN 13241-1 2003

25014 CASTENEDOLO (BS)-ITALY

Via Matteotti, 162 Telefono +39.030.2135811 Telefax +39.030.21358279-21358278 http://www.ribind.it - email: [email protected] automatismi per cancelli automatic entry systems ® KING - KING PLUS - KING L - KING L PLUS Cod. CVA1265 - 04072007 - Rev. 26 Seeger E17 Seeger E20 Seeger E25 Spina cilindrica 8x32 Rosetta MB3 17x1 per KING PLUS E KING L PLUS Molla per sblocco serie KING Molla trazione coperchio serie KING Anello di tenuta OR2037 Ghiera KM3 per KING PLUS E KING L PLUS Boccola 12x16x12 Bronzo F7/R7 Cilindretto per serratura serie KING Vite aut. TC CR 2,9x9,5 zincata per PLUS Dado Autob. 8MA alto Inox Dado Autob. M10 Alto Inox Rondella Piana 10X20 Inox Rondella Piana 10X30 Inox Rondella Piana 12X24 Rondella Piana 8,4X17X1,6 Vite TCEI 5,5X38 Autof. Zinc. Vite TC Croce 5,5x50 Vite TCEI 6X30 Inox UNI5931 Vite TC.CR. 3X35 Vite TE 8X25 Inox UNI5739 Vite TE 8X30 Inox UNI5739 Vite TE 10X40 Inox UNI 5737 CTC1119 CTC1120 CTC1123 CTC1214 CTC1244 CTC1258 CTC1259 CTC1307 CVA1027 CVA1176 CVA1325 DAC29X95 DDD8MAI DDD10MAI DRL10X20I DRL10X30I DRL12X24Z DRL8X17 DTB55X40 DTC55X50Z DTE10X20I DTC3X35Z DTE8X25I DTE8X30I DTM10X40I ACG8089 BA01019 BA10052 BC00207 CAL1099 CAL1160 CAL1161 CAL1162 CAL1163 CME6082 CCA1233 CCA1294 CCA1299 CCA1319 CCA1328 CCA1351 CCA1355 CCA1370 CCM6005ZZ CCM6202ZZ CEL1425 CEL1426 CEL1513 CEL1518 Gruppo Fermo meccanico di chiusura OPZIONALE Serie accessori per cilindro KING Gruppo Chiocciola serie KING Circ. Forcellino Ottico KING PLUS e KING L PLUS 230/50 Fermo superiore serie KING Semiguscio inferiore KING e KING PLUS Semiguscio superiore KING e KING PLUS Semiguscio inferiore KING L e KING L PLUS Semiguscio superiore KING L e KING L PLUS Forcella Posteriore serie KING Disco Encoder KING PLUS e KING L PLUS PIATTO COLONNA REGOLABILE serie KING Fermo inferiore serie KING Piatto fissaggio colonna serie KING L Piatto attacco cancello serie KING L Attacco cancello serie KING ANGOLARE ATTACCO A COLONNA (2 pezzi) serie KING Piastra attacco colonna serie KING L Cuscinetto motore 6005ZZ Cuscinetto motore 6202ZZ Condensatore 10µF 450V x serie 230V/50 Condensatore 35µF 450V x serie 120V/60 Connettore MPM Art.18311 N21 Pressacavo antipiega BS11 PG11 Codice Denominazione Particolare CEL1524 CME1299 CME2042 CME2041 CME9129 CME9130 CME9785 CME9868 CMO1198 CMO1199 CMO1241 CMO1242 CMO1263 CMO1264 CMO1265 CMO1266 CPL1087 CPL1157 CPL1158 CPL1159 CPL1160 CPL1161 CRS62042R CTC1004 CTC1008 CTC1117 Connettore MPM Art.C19307 N62 per KING PLUS e KING L PLUS Perno per ingranaggio serie KING Corona elicoidale sblocco sx Corona elicoidale dx serie KING Vite madre KING L e KING L PLUS Vite madre KING e KING PLUS Perno Sblocco serie KING Perno di traino serie KING Statore KING e KING L 230V/50Hz 1P H70 Statore KING PLUS e KING L PLUS 230V/50Hz 1P H70 Rotore KING e KING L con albero Rotore KING PLUS e KING LPLUS con albero Statore KING 120V/60Hz 1P H70 Statore KING 220V/60Hz Statore KING 120V/60Hz 1P H70 PLUS Statore KING 220V/60Hz PLUS Ingranaggio conico Tappo per fermo meccanico serie KING Guida porta cilindro Coperchio per viti Cassetto copri serratura serie KING Ingranaggio conico serie KING Cuscinetto 6204/2RS Chiavetta 6 6 12 Chiavetta 6 6 30 Seeger E15 per KING PLUS e KING LPLUS Codice Denominazione Particolare Codice Denominazione Particolare Questo prodotto è stato completamente progettato e costruito in Italia · Ce produit a été complètement développé et fabriqué en Italie · This product has been completely developed and built in Italy · Dieses Produkt wurde komplett in Italien entwickelt und hergestellt · Artìculo totalmente proyectado y producido en Italia