CLEANING SOLENOID VALVE

1. Unscrew the screws like the picture 2. Extract the rubber membrane. 3. Check if there are impurities and clean. 4. Clean the holes on the rubber membrane. SOLENOID VALVE TECHNICAL DRAWING G1/2 97,5 G1/2 SW23 ELECTRONIC MIXER TAP POWER SUPPLY : 4x1,5V batteries AA TECHNICAL DATA – INSTRUCTION FOR THE ASSEMBLAGE – PRECAUTIONS FOR USE ZEUS003 Serie R

INFORMATIONS FOR THE USER

SPECIFICATIONS: POWER SUPPLY Alkaline batteries (4x1,5V AA) MINIMUM WORKING PRESSURE 0,5 bar MAXIMUM WORKING PRESSURE 4 bar MAXIMUM WORKING TEMPERATURE 70°C MINIMUM SENSING DISTANCE 0,5cm MAXIMUM SENSING DISTANCE 15 cm FLOW RANGE 5 l/min with 3 bar pressure FLEXIBLES CONNECTION G 1/2" F FLEXIBLES LENGHT 35 cm WARNING LOW BATTERY yes VANDAL PROOF SYSTEM yes ANTI-LEGIONELLA SYSTEM yes ASSEMBLY INSTRUCTIONS: In case of new plumbing , always proceed to drain the pipes before installation. 1. Turn off the water supplies. 2. Screw the stay bolt (H) to the mixer tap (G). Insert the base (I), the O-Ring (J) and screw the flexibles (B) to the mixer tap (G). 3. Place the tap on the sink by passing the flexibles (B) and the sensor cables (C1,C2) in the sink hole, staring it with the fixing kit. 4. Screw the swinging spout (F) to the tap (G). 5. Connect the solenoid valves (D) to the flexibles (B) according to the input of the water (see pic. 1). 6. Connect the connectors (K) to the solenoid valves (D), paying attention to the polarity of the cables (see pic. 1). 7. Secure the battery holder (E) on the wall under the sink, using the velcro and making sure that the cable outlet is facing downward. (see pic. 2) 8. Insert the 4 alkaline batteries in the battery holder (E). Pay attention to the poles + and -. 9. Conect the cable (C1) to the battery holder (E). FUNCTIONING: The infrared sensor (A) identifies the presence of the hands and the valve begins to provide the water till the sensor will no more detect the hands in front of the sensor or until the expiration of the maximum time of closing (VANDAL PROOF SYSTEM). If the infrared system detects an object for 5 minutes, the system cut off the water supply until the object will not be removed. Once the foreign object has been removed, the tap will resume regular operation. The low battery is indicated by flashing red LED light with increasing speed. The solenoid valve closes and the system hangs waiting for the battery replacements. After 24 hours of non-use, the tap is automatically activated to prevent the LEGIONELLA bacterium (ANTI-LEGIONELLA SYSTEM). Failure to supply water, check that the batteries are charged and/or correctly positioned. The operation of the tap is guaranteed only with water free of impurities, therefore it is important install the faucet filters. FAILURE IN FOLLOW THE INFORMATIONS CONTAINED IN THIS LEAFLET WILL INVALIDATE THE WARRANTY Battery holder D A B C1 E F G H C2 I J pic. 2 K Serie R Serie R Solenoid valve pic. 1

ALIMENTAZIONE : BATTERIE ALCALINE (4x1,5v AA)

POWER SUPPLY : Alkaline batteries (4x1,5V AA) ZEUS003