Mitsubishi Electric MELSEC iQ-F Series Programming Manual

File Specifications

Brand: Mitsubishi Electric
Category: Controller
Model: MELSEC iQ-F Series (Programming Manual), prFoPQiZr2a/I
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 128 pages

Download PDF

Download Mitsubishi Electric MELSEC iQ-F Series Manual (128 pages)

Read Online:

Read the Mitsubishi Electric MELSEC iQ-F Series Programming Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

8 SFC PROGRAM

8.2 Structure Normal step (without attribute) A basic step used to configure a block. While this type of step is active, the transition condition following the step is constantly checked, and when the transition becomes TRUE, the next step becomes active. The output status of the action of a step at a transition to the next step varies depending on the instruction used. ■Step without action A step without an action can also be used as a waiting step. • While a step is active, the transition is always checked and, when the transition becomes TRUE, the next step becomes a ...

3 PROGRAM ORGANIZATION UNITS

3.3 Function Blocks (FB) 25 3 EN and ENO In the same way as a function, EN (enable input) and ENO (enable output) can also be appended to a function block to control execution processing. Page 14 EN and ENO When the instance of a function to which EN/ENO has been appended is called, an actual argument must be assigned to EN. Creating programs The program of a function block can be created by using the engineering tool. [Navigation window]  [FB/FUN]  Right-click  [Add New Data] Select "Function Block" for "Data Type" in "Basic Setting". The created pro ...

8 SFC PROGRAM

8.2 Structure 81 8 Block start step (without END check) [BS] Block start step (without END check) [BS] is a step that activates the specified block. When the transition becomes TRUE, the active state transitions to the next step. The operation to be performed if multiple attempts to start one block are performed simultaneously or if an attempt to start an already started block is performed depends on "Act at block Multi-Activated." (Page 100 Act at block Multi-Activated) Only one block can be specified. To start multiple blocks simultaneously, use parallel branches and multi ...

3 PROGRAM ORGANIZATION UNITS

3.3 Function Blocks (FB) 21 3 Instances ■Instances An instance is a label assigned to realize a function block definition. Multiple instances can be created from one function block definition. An instance consists of the following items. Ex. Structure of instance (Example of subroutine type function block) For the local label area and local latch label area, since the label area is secured in units of four words, three-words (padding size) are secured in the above example. Each area occupies a reserved area. The reserved area is used to add or change the local ...

Mitsubishi Electric MELSEC iQ-F Series user guide recommended for: AJ61BT11, MELDAS 60 Series, MELSEC ST Series, Q172CPU, L61P.

⚠️ Download Safety

The Controller Programming manual (128 pages) is completely safe to download (last scan date: 31/01/2026).

Related PDF Instructions for Mitsubishi Electric MELSEC iQ-F Series:

Controller Equipment: Frequently Requested

Have some Questions about Mitsubishi Electric MELSEC iQ-F Series Device?

Get valuable and actionable advices from other Mitsubishi Electric MELSEC iQ-F Series device users. Describe your problem or question, regarding the using of MELSEC iQ-F Series, in as much detail as possible, and other users will be able to answer you.