Paradox NV5 Installation Instructions

Specifications

Brand: Paradox
Category: Security Sensors
Model: NV5 (Installation Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Paradox NV5 Installation Instructions online using the built-in PDF viewer.

Text of the manual

NV5 Installation Instructions

NV5-EI02 - 09/2019 Please read all installation instructions before installing the unit. Figure 1: NV5 Back Plate 1. Select detector location using Figure 2 as a guide. The detector must be installed at 2.1m (7.0 ft) or higher. Figure 2: Beam Pattern 2. Loosen the locking screw (9), located at the bottom of the unit. 3. Separate the front cover from the back plate. 4. Separate the PCB board from the back plate 5. On the back plate drill holes for the wire pass-thru (2) and appropriate knockout holes. For wall mount drill holes (3), (10) and (15). For corner mount drill holes (5), (7), (12) and (14). For bracket mount drill hole (4). 6. Secure back plate to surface. For wall mount, pass wires through hole (2) of the back plate and secure with screws at (3), (10) and (15). For a corner mount, pass wires through hole (2) of the back plate and secure with screws at (5), (7), (12) and (14). Figure 3: SB100 Bracket Assembly Installation For bracketed ceiling mount (with SB100), insert ceiling accessory (21) and orient as per (23). Insert the Bracket Retainer (25).Pass wire from ceiling through(25),through (17) and through hole (2) of the back plate. Secure bracket to ceiling with screws at (16). Secure back plate with a screw at (4) onto bracket at (18). For bracketed wall mount (with SB100), insert wall accessory (22) and orient as per (24). Pass wire from wall through (25), through (20) and through hole (2) of the back plate. Secure bracket to wall with screws at (16) Secure back plate with a screw at (4) onto bracket at (19). 7. Snap the PCB board onto the back plate. 8. Connect wires to terminal board (1) as per Figure 4. Figure 4: Terminal Board Wiring Callout Description 16 Bracket mounting holes 17 Wire pass-thru (ceiling) 18 Ceiling mount 19 Wall mount 20 Wire pass-thru (wall) 21 Ceiling Accessory 22 Wall Accessory 23 Ceiling Accessory Orientation 24 Wall Accessory Orientation 25 Bracket Retainer ALARM OUTPUT N.C. COM BLK RED TAMPER 12 Vdc N.C. Callout Description 1 Terminal board 2 Wire pass-through 3 Wall mount (knockout) 4 Bracket mount (knockout) 5 Corner mount (knockout) 6 Trimpot (sensitivity 1-5) 7 Corner mount (knockout) 8 Tamper switch 9 Locking screw 10 Wall mount (knockout) 11 Sensor 12 Corner mount (knockout) 13 Jumpers (profile/LED) 14 Corner mount (knockout) 15 Wall mount (knockout)

NV5-EI02 - 09/2019

9. Adjust jumpers (13) for profiles (1-4) and LED ON / OFF (of an alarm) using this table: 10. Configure sensitivity via trimpot (6), default setting = 3. Adjust from 1 (8m / 26.3 ft), 2 (9m / 29.5 ft), 3 (10m / 32.8 ft), 4 (11m / 36.1 ft), 5 (12m /39.4 ft). Turn the trimpot clockwise to increase sensitivity. Turn the trimpot counterclockwise to decrease sensitivity. Warning: The sensitivity trimpot is fragile. Do not over torque. 11. Install front cover onto back plate. 12. Secure front cover to back plate with locking screw (9). 13. Perform power up sequence. LED and relay will toggle on / off for 4 seconds. Sensitivity level indication: The LED flashes 1 to 5 times to indicate trimpot position. Jumper setting indication: The LED flashes 1 to 4 times to indicate jumper setting. Total power-up sequence = 10 seconds. Detector is ready for alarm detection. During alarm the LED is ON for 3 seconds (if set). Recommendations: Do not install in areas with large temperature fluctuations as caused by direct sunlight, or heating / cooling equipment. Do not install where airflow changes can cause objects to move into the detector path. Do not install where dust or residue can accumulate onto the detector. Do not install in areas with pets weighing more than 16 kg (35 lbs). Notes: The mirror option is pre-installed when ordered (no installation is necessary). The SB100 bracket assembly is optional and can be installed for a ceiling or wall mount. The sensor (11) does not require maintenance. The tamper switch (8) is pressed down when the front cover is attached and closed Legal: Patents: One or more of the following US Patents 1,302,541 5,077,549 D680010 and other patents pending may apply. Canadian and international patents may also apply. Trademarks: ENVY Series is a trademark of Paradox Security Systems (Bahamas) Ltd. or its affiliates in Canada, the United States and/or other countries. Certification: For the latest information on products approvals, visit www.paradox.com. Warranty: For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. © 2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may change without prior notice. Profile # (LED Flashes) Profile Name Interference Level (APSP) Processing Type (EDGE) JUMPER SETTINGS LED ON LED OFF 1 Normal Normal* Single* 2 Moderate Normal Dual 3 Pet resistant High Single 4 Harsh High Dual The NV5 features 4 pre-programmed profile settings. The number associated with the profile (1 to 4) depicts the number of LED flashes when changing jumper settings. APSP: Set for the expected interference level of the environment (normal / high). EDGE: The detector can be set to process for partially crossing the beam (single) or for fully crossing the beam (dual) for increased detection performance. NORMAL: Use for normal environments that have minimal interference. MODERATE: This profile provides better false alarm rejection. PET RESISTANT: Set the Pet Resistant profile for pets that weigh up to 16 kg (35 lbs). HARSH: Use the Harsh profile when the detector is installed in high-risk environments (potential interference) and to provide greatly increased false alarm immunity. * Default Jumper Settings (APSP = Normal, EDGE = Single, LED = ON) Technical Specifications Installation height 2.1m – 3.1m (7.0 ft – 11.0 ft) Current consumption 10.5 mA @ Standby / 11.3 mA @ Alarm Power input 10 Vdc to 15 Vdc Coverage 10m (32.8 ft) x 90°, 0.1 to 0.5m (0.3 to 1.6 ft) creep zone Alarm output Solid State, N.C. 150 mA Anti-tamper switch N.C. 28 Vdc, 0.15A Operating temperature -10°C to 50°C (14°F to 122 °F) at 95% max. humidity Dimensions 9.1 x 5.5 x 4 cm (3.5 x 2.2 x 1.6 in.) RF Immunity EN 50130-4: 10V/m 80 MHz to 2 GHz Standards EN 50131-2-2 Security Grade 2 / Environmental Class I *

Other Security Sensors Manuals