NV5 Installation Instructions
NV5-EI02 - 09/2019
Please read all installation instructions before installing the unit.
Figure 1: NV5 Back Plate
1.
Select detector location using Figure 2 as a guide. The detector must be installed at
2.1m (7.0 ft) or higher.
Figure 2: Beam Pattern
2.
Loosen the locking screw (9), located at the bottom of the unit.
3.
Separate the front cover from the back plate.
4.
Separate the PCB board from the back plate
5.
On the back plate drill holes for the wire pass-thru (2) and appropriate knockout holes.
For wall mount drill holes (3), (10) and (15).
For corner mount drill holes (5), (7), (12) and (14).
For bracket mount drill hole (4).
6.
Secure back plate to surface.
For wall mount, pass wires through hole (2) of the back plate and secure with screws at
(3), (10) and (15).
For a corner mount, pass wires through hole (2) of the back plate and secure with
screws at (5), (7), (12) and (14).
Figure 3: SB100 Bracket Assembly Installation
For bracketed ceiling mount (with SB100), insert ceiling accessory (21) and orient as
per (23). Insert the Bracket Retainer (25).Pass wire from ceiling through(25),through
(17) and through hole (2) of the back plate. Secure bracket to ceiling with screws at
(16). Secure back plate with a screw at (4) onto bracket at (18).
For bracketed wall mount (with SB100), insert wall accessory (22) and orient as per
(24). Pass wire from wall through (25), through (20) and through hole (2) of the back
plate. Secure bracket to wall with screws at (16) Secure back plate with a screw at (4)
onto bracket at (19).
7.
Snap the PCB board onto the back plate.
8. Connect wires to terminal board (1) as per Figure 4.
Figure 4: Terminal Board Wiring
Callout
Description
16
Bracket mounting holes
17
Wire pass-thru (ceiling)
18
Ceiling mount
19
Wall mount
20
Wire pass-thru (wall)
21
Ceiling Accessory
22
Wall Accessory
23
Ceiling Accessory
Orientation
24
Wall Accessory Orientation
25
Bracket Retainer
ALARM OUTPUT
N.C. COM BLK RED TAMPER
12 Vdc
N.C.
Callout
Description
1
Terminal board
2
Wire pass-through
3
Wall mount (knockout)
4
Bracket mount (knockout)
5
Corner mount (knockout)
6
Trimpot (sensitivity 1-5)
7
Corner mount (knockout)
8
Tamper switch
9
Locking screw
10
Wall mount (knockout)
11
Sensor
12
Corner mount (knockout)
13
Jumpers (profile/LED)
14
Corner mount (knockout)
15
Wall mount (knockout)
NV5-EI02 - 09/2019
9.
Adjust jumpers (13) for profiles (1-4) and LED ON / OFF (of an alarm) using this table:
10. Configure sensitivity via trimpot (6), default setting = 3.
Adjust from 1 (8m / 26.3 ft), 2 (9m / 29.5 ft), 3 (10m / 32.8 ft), 4 (11m / 36.1 ft),
5 (12m /39.4 ft).
Turn the trimpot clockwise to increase sensitivity.
Turn the trimpot counterclockwise to decrease sensitivity.
Warning: The sensitivity trimpot is fragile. Do not over torque.
11. Install front cover onto back plate.
12. Secure front cover to back plate with locking screw (9).
13. Perform power up sequence.
LED and relay will toggle on / off for 4 seconds.
Sensitivity level indication: The LED flashes 1 to 5 times to indicate trimpot position.
Jumper setting indication: The LED flashes 1 to 4 times to indicate jumper setting.
Total power-up sequence = 10 seconds.
Detector is ready for alarm detection. During alarm the LED is ON for 3 seconds (if set).
Recommendations:
Do not install in areas with large temperature fluctuations as caused by direct sunlight, or
heating / cooling equipment.
Do not install where airflow changes can cause objects to move into the detector path.
Do not install where dust or residue can accumulate onto the detector.
Do not install in areas with pets weighing more than 16 kg (35 lbs).
Notes:
The mirror option is pre-installed when ordered (no installation is necessary).
The SB100 bracket assembly is optional and can be installed for a ceiling or wall mount.
The sensor (11) does not require maintenance.
The tamper switch (8) is pressed down when the front cover is attached and closed
Legal:
Patents: One or more of the following US Patents 1,302,541 5,077,549 D680010 and other
patents pending may apply. Canadian and international patents may also apply.
Trademarks: ENVY Series is a trademark of Paradox Security Systems (Bahamas) Ltd. or
its affiliates in Canada, the United States and/or other countries.
Certification: For the latest information on products approvals, visit www.paradox.com.
Warranty: For complete warranty information on this product please refer to the Limited
Warranty Statement found on the website www.paradox.com/terms.
© 2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may
change without prior notice.
Profile #
(LED
Flashes)
Profile
Name
Interference
Level (APSP)
Processing
Type (EDGE)
JUMPER SETTINGS
LED ON
LED OFF
1
Normal
Normal*
Single*
2
Moderate
Normal
Dual
3
Pet resistant
High
Single
4
Harsh
High
Dual
The NV5 features 4 pre-programmed profile settings. The number associated with
the profile (1 to 4) depicts the number of LED flashes when changing jumper
settings.
APSP: Set for the expected interference level of the environment (normal / high).
EDGE: The detector can be set to process for partially crossing the beam
(single) or for fully crossing the beam (dual) for increased detection
performance.
NORMAL: Use for normal environments that have minimal interference.
MODERATE: This profile provides better false alarm rejection.
PET RESISTANT: Set the Pet Resistant profile for pets that weigh up to 16 kg (35 lbs).
HARSH: Use the Harsh profile when the detector is installed in high-risk
environments (potential interference) and to provide greatly increased
false alarm immunity.
* Default Jumper Settings (APSP = Normal, EDGE = Single, LED = ON)
Technical Specifications
Installation height
2.1m – 3.1m (7.0 ft – 11.0 ft)
Current consumption
10.5 mA @ Standby / 11.3 mA @ Alarm
Power input
10 Vdc to 15 Vdc
Coverage
10m (32.8 ft) x 90°, 0.1 to 0.5m (0.3 to 1.6 ft) creep zone
Alarm output
Solid State, N.C. 150 mA
Anti-tamper switch
N.C. 28 Vdc, 0.15A
Operating temperature
-10°C to 50°C (14°F to 122 °F) at 95% max. humidity
Dimensions
9.1 x 5.5 x 4 cm (3.5 x 2.2 x 1.6 in.)
RF Immunity
EN 50130-4: 10V/m 80 MHz to 2 GHz
Standards
EN 50131-2-2 Security Grade 2 / Environmental Class I
*