QUICK USER MANUAL

RASHA PROFESSIONAL A/S Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585 Rashaprofessional.com | [email protected] 1 User Manual Please read this user manual before using this product.

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] I. Checking before Using No. Items Quantity Unit 1 Edge 1 Pc 2 Hanging Bracket 2 Pcs 3 Power Cable 1 Pc 4 User Manual 1 Pc 5 Hook Optional 6 Safety Wire 7 DMX Cable 1. When opening the packing, take all accessories out, and remove the light to a horizontal table for good operation. First check whether the accessories are complete, then check carefully whether the whole light has no damage. If there is any damage, please contact us as soon as possible. 2. AC Power: Check whether the local power supply is accordance with the requirements of the product rated voltage.3.The product is only suitable for indoor working environment. The light should keep dry, keep away from wet, overheat or dusty environment. Don't come into contact with water and other liquids to prevent or reduce the risk of electric shock or fire. 3.The product is only suitable for indoor working environment. The light should keep dry, keep away from wet, overheat or dusty environment. Don't come into contact with water and other liquids to prevent or reduce the risk of electric shock or fire. 4. Please do not install the light directly on the surface of the combustible substance. 5. The people who install, operate and maintain of light professional certificate required. 6. When there are faults of the light, please stop using the light immediately. Don't try to repair, please contact the nearest authorized technical assistance center, if the parts damage, always use the same type of parts replaced. 7. Don't touch any electrical wiring in the process of operation to prevent the risk of electric shock.

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] 8. To make sure the light working environment temperature, the highest do not exceed 40℃,the lowest do not exceed - 20 ℃. 9. Under the stable cooling working situation, the highest temperature of the housing of the light can reach 80 ℃, please do not touch. 10. The light is design according to the type of electric shock protection. The light should be use in good connection grounding power system and the earth sign port of the light should be connected to the installing fixtures. 11. Do not use the damage of the insulating layer wire and also do not use the power cord overlap on the other wire. When not in use or clean the light, please disconnect the power, don't pull the plug in hard or just drag the wires. 12. There are no components inside for maintenance. Before start operation the light, please check whether all of the shell is installed. In the case of the shell open used the light is prohibited. Note: Under any installation, maintenance and clean the light, please confirm that has cut off the power cord! II. Safety Instruction ★For security reasons and in accordance with the term’s, reassemble or modify the product is not allowed without permission. Please note that due to human damage caused by improper use of the product, will break the warranty qualification. Moreover, the unprofessional operation may lead to short circuits, burns or electric shock, and so on. ★This device has been full inspection before shipping. For your safety, please operate it according the User Manual. ★If any damage caused by improper operation will result in the termination of the warranty claims. The manufacturer does not accept any responsibility of property damage due to improper operation or personal injury due to non-compliance with the operating instructions. ★Keep the manual in a safe place for future reference as well as after the product sale, lease, etc.. ★Note: Based on product improvements, specification may change without notice. Changes in product specifications related rights will be reserved.

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] III. Product Specification 1.Built-in Master/Slave, DMX, Sound Active, powerful effects mode. 2.LCD 2.4 inch TFT LCD screen, easy to operate. 3.Suitable for discotheques, clubs, bars, parties, mobile DJs, concerts and more. 4.DMX Channel: 16CH, 21CH and 36CH. 5.Four Operational Modes: Sound (Audio) Active, Show Mode, DMX, Master / Slave; 6.Unlimited rotation, X/Y 360 ° infinite rotation. 7.Voltage: AC100-240V 50-60Hz. 8.Fuse: F5AL250V. 9.Power Consumption: P = 300W 10. light source: 5*40W RGBW 4in1, 250*0.2W RGB strobe. 11. Net weight: 11kg 12. Size: 51.5 * 18.0 * 28.2cm 13. Lumine LED Color @1M Beam Unit 1 Pcs 40W LED 1R 8200 6 LUX 1G 15000 1B 19000 1W 20000 1RGBW 56000 250*0.2W RGB Strobe R 165 G 430 B 400 RGB 930

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] IV. Function Instruction Item SO Silkscreen Function Button 1 Menu Enter/Check Menu 2 Up Check the Last Menu 3 Down Check the Next Menu 4 Enter Enter the Menu or Confirm V. LCD Display Main Function System Settings Menu 1 Menu 2 Menu 3 Function DMX Address 512 001 - 512 DMX Address Code DMX Mode CH-16 16 DMX Channel CH-21 21 DMX Channel CH-36 36 DMX Channel Auto Mode Show Mode Auto 0 Random Shoe Auto 1-4 Show 1-4 Show Speed 01 - 99 Slow Fast Sound Mode Off Sound Open On Sound Close Speed 00 - 99 00 - 99 Sound Sensitivity

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] System Settings Menu 1 Menu 2 Menu 3 Function Slave Mode Slave 1 Slave 1 Slave 2 Slave 2 Advanced Settings Reset No/Yes Reset, No/Yes Pan Invert No/Yes Pan inverse, No/Yes Tilt Invert No/Yes Tilt inverse, No/Yes Display Off/On LCD Switch, Off/On Display Inverse No/Yes Display Inverse No Language English English Chinese Chinese DMX Fail, No DMX Auto Auto Black Black Hold Hold Soft Ware V1.0 V1.0 VI. How to Operation (Here are 2 Ways to Operate) 1. Master/slave build-in program to control 2. DMX controller A. Main and auxiliary functions All lamps and lanterns are initially installed on the main machine, and the lamps and lanterns are connected in series. You can also specify one for the host and the rest for slave. VII. DMX Controller If controlled by DMX controller, you need to set the DMX address code to control the light, the address code value is between 1-512, then the light will receive the signal accordingly. Press MENU button, select Address menu, press ENTER button, address will strobe. Use △/▽ to select DMX512 address, our factory value set as “Address 001”. After setting DMX address, press ENTER button.

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] Connect the DMX512 console output port to the first slave device DMX input, and connect the first slave device DMX output signal to the second slave device DMX input signal, until all slave connections are complete. During the installation, if the signal line is too long, or in relatively noisy electrical environments, such as dance halls, we recommend using DMX terminator (circuit connection). It can avoided the control signal turbidity due to electrical noise. DMX terminal is connected by a simple XLR head (2-pin and 3-pin) connecting a 120Ω resistor, please set the terminal into the final device output port, please refer to the diagram.

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] VIII. Specification Physical Weight 11.3kg (24.9 lbs) Dimensions 539.75x184.15x323.85 mm (21.25x7.25x12.75 in) Dynamic Effeects Color Mixing RGBW & RGB Pan/Tilt Unlimited Rotation,X/Y 360u00ba Infinite Rotation Electronic Dimming 0 - 100%, Four Dimming Curve Options Tilt Speed Adjustable Via on-board Control Panel & DMX Stobe & Pluse Effect Variable Speed, Random Strobe Optics Light Source 5x40W RGBW & 250x.2W RGB Strobe Minimum LED Lifetime 50,000 Hrs(>70% Luminous Output )* *Obtained under Manufactures test conditions Control & Programming Control Options DMX, Master/Slave, Sound Active & Show Mode DMX Channels 16,21 & 36 Ch Setting, Addressing & Pro. Control Panel with LCD Protocol USITT DMX 512/1990 or DMX512 Universal Trans-Reciver RS-485 Stand-Alone Trigger Option Auto Trig, Sound Trig Construction Color Black Housing UV-Resistant Fiber-Reinorced Composite/Thermal Reflector High Precious Optical Lens Protection Rating IP20 Electrical Power Consumption 300W Power Supply Unit Auto-Ranging Electronic Switch-Mode AC Power Input Powercon In AC Power Through Put Powercon Out DMX Data In/Out 3-Pin Locking XLR Fuse F5AL250V Approval EU Safety / EU EMC EN 60598-2-17/EN 55015, EN 55103-1, EN 61547 Canadian Safety (US Model) UL 1573/ FCC Part 15 Class A Included Items Omega Clamp Bracket P/N 890505 Power Input Cable 5ft with PowerCon Blue Connector P/N 890507 DMX Input Cable 5ft with 3 Pin P/N 890508 Accessories Wireless DMX Transmitter* P/N 920101 Safety Wire* P/N 890110 Road Case 2 in 1* P/N 816102 *All Accessories Sold Separately Installation Mounting Surface or Truss Mount / Free Standing Orientation Any Location Indoor Use Only Thermal Maximum Ambient Temperature (Ta Max.) 50° C (122° F) Minimum Ambient Temperature (Ta Min.) 0°C (32°F) Cooling System Internal Cooling Fan Ordering Information Edge in Card Board Box P/N 816100 Edge Road Case 2 in 1 P/N 816102

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] IX. Channel (Select DMX address 001 default address) (Schedule 1) DMX Channel (16 CH) – (DMX Address 001) CH Value Function CH1 000 - 255 Tilt movement,540°Adjustable Pan CH2 000 - 255 Speed fast-slow CH3 000 - 049 No Function 050 - 149 Anticlockwise unlimited rotation, 150 - 255 Stop rotation 156 - 255 Clockwise unlimited rotation CH4 000 - 255 Tilt movement,360°Adjustable CH5 000 - 255 Move speed fast-slow CH6 000 - 049 No Function Tilt 050 - 149 Unlimited rotation (Down), Fast Slow 150 - 155 Stop rotation 156 - 255 Unlimited rotation (up), Slow-Fast CH7 000 - 255 Brightness 0 - 100% Dimmer CH8 000 - 255 Red linear dimmer 0 - 100% 40W LED CH9 000 - 255 Green linear dimmer 0 - 100% CH10 000 - 255 Blue linear dimmer 0 - 100% CH11 000 - 255 White linear dimmer 0 - 100% CH12 000 - 255 Red linear dimmer 0 - 100% SMD RGB CH13 000 - 255 Green linear dimmer 0 - 100% CH14 000 - 255 Blue linear dimmer 0 - 100% CH15 000 - 007 LED Open LED Switch / Strobe 008 - 015 LED Close 016 - 131 Strobe, Slow to fast, 1-25Hz 132 - 139 LED Open 140 - 181 LED quick slow off, slow-fast 182 - 189 LED Open 190 - 231 LED quick off slow on, slow-fast 232 - 239 LED Open 240 - 247 Random Strobe 248 - 255 LED Open CH16 000 - 199 No Function Reset 200 - 209 Automatic reset after 3S 210 - 255 No function

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] (Schedule 2) DMX Channel (21 CH) – (DMX Address 001) CH Value Function CH1 000 - 255 Tilt movement,540°Adjustable Pan CH2 000 - 255 Speed fast-slow CH3 000 - 255 X fine CH4 000 - 049 No Function 050 - 149 Anticlockwise unlimited rotation, 150 - 155 Stop rotation 156 - 255 Clockwise unlimited rotation CH5 000 - 255 Tilt movement,360°Adjustable Tilt CH6 000 - 255 Move speed fast-slow CH7 000 - 255 Y fine CH8 000 - 049 No Function 050 - 149 Unlimited rotation (Down), Fast Slow 150 - 155 Stop rotation 156 - 255 Unlimited rotation (up), Slow-Fast CH9 000 - 255 Brightness 0 - 100% Dimmer CH10 000 - 255 LED1 static dimmer 40W LED CH11 000 - 255 LED2 Static dimmer CH12 000 - 255 LED3 static dimmer CH13 000 - 255 LED4 static dimmer CH14 000 - 255 LED5 static dimmer CH15 000 - 255 Red linear dimmer 0 - 100% SMD RGB CH16 000 - 255 Green linear dimmer 0 - 100% CH17 000 - 255 Blue linear dimmer 0 - 100% CH18 000 - 007 LED Open LED Switch / Strobe 008 - 015 LED Close 016 - 131 Strobe, Slow to fast, 1-25Hz 132 - 139 LED Open 140 - 181 LED quick slow off, slow-fast 182 - 189 LED Open 190 - 231 LED quick off slow on, slow-fast 232 - 239 LED Open 240 - 247 Random Strobe 248 - 255 LED Open

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] CH19 000 - 007 No Function Show / Sound Active 008 - 022 Show 1 023 - 037 Show 2 038 - 052 Show 3 053 - 067 Show 4 068 - 082 Show 5 083 - 097 Show 6 098 - 112 Show 7 113 - 127 Show 8 128 - 142 Show 9 143 - 157 Show 10 158 - 172 Show 11 173 - 187 Show 12 188 - 202 Show 13 203 - 217 Show 14 218 - 232 Show 15 233 - 247 Show 16 248 - 255 Sound active CH20 000 - 127 Show speed, Slow-fast Speed/Soun d Switch 128 - 240 Sound close 241 - 255 Sound open CH21 000 - 199 No Function Reset 200 - 209 Automatic reset after 3S 210 - 255 No Function

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] (Schedule 3) DMX Channel (36 CH) – (DMX Address 001) CH Value Function CH1 000 - 255 Tilt movement,540°Adjustable Pan CH2 000 - 255 Move Speed, Fast-Slow CH3 000 - 255 X fine CH4 000 - 255 Unlimited rotation CH5 000 - 255 Tilt movement, 360°adjustable Tilt CH6 000 - 255 Move Speed, Fast-Slow CH7 000 - 255 Y fine CH8 000 - 255 Unlimited rotation CH9 000 - 255 Brightness 0 - 100% Dimmer CH10 000 - 255 R1 dimmer 0 - 100% LED1 CH11 000 - 255 G1 dimmer 0 - 100% CH12 000 - 255 B1 dimmer 0 - 100% CH13 000 - 255 W1 dimmer 0 - 100% CH14 000 - 255 R2 dimmer 0 - 100% LED2 CH15 000 - 255 G2 dimmer 0 - 100% CH16 000 - 255 B2 dimmer 0 - 100% CH17 000 - 255 W2 dimmer 0 - 100% CH18 0 - 255 R3 dimmer,0-100% LED3 CH19 0 - 255 G3 dimmer,0-100% CH20 0 - 255 B3 dimmer,0-100% CH21 0 - 255 W3 dimmer,0-100% CH22 0 - 255 R4 dimmer,0-100% LED4 CH23 0 - 255 G4 dimmer,0-100% CH24 0 - 255 B4 dimmer,0-100% CH25 0 - 255 W4 dimmer,0-100% CH26 0 - 255 R5 dimmer,0-100% LED5 CH27 0 - 255 G5 dimmer,0-100% CH28 0 - 255 B5 dimmer,0-100% CH29 0 - 255 W5 dimmer,0-100% CH30 0 - 255 Red linear dimmer,0-100% SMD CH31 0 - 255 Green linear dimmer,0-100% CH32 0 - 255 Blue linear dimmer,0-100%%

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] CH33 000 - 007 LED open LED Switch/ Strobe 008 - 015 LED close 016 - 131 Strobe, slow to fast, 1-25Hz 132 - 139 LED open 140 - 181 LED quick on slow off, slow-fast 182 - 189 LED open 190 - 231 LED quick off slow on, slow-fast 232 - 239 LED open 240 - 247 Random strobe 248 - 255 LED open CH34 000 - 007 No function Show/Sound active 008 - 022 Show 1 023 - 037 Show 2 038 - 052 Show 3 053 - 067 Show 4 068 - 082 Show 5 083 - 097 Show 6 098 - 112 Show 7 113 - 127 Show 8 128 -142 Show 9 143 - 157 Show 10 158 - 172 Show 11 173 - 187 Show 12 188 - 202 Show 13 203 - 217 Show 14 218 - 232 Show 15 233 - 247 Show 16 248 - 255 Sound Active CH35 000 - 127 Show Speed, Slow - Fast Speed / Sound Switch 128 - 240 Sound Close 241 - 255 Sound open CH36 000 - 199 No Function Reset 200 - 209 Automatic reset after 3S 210 - 255 No Function

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] X. Product Care & Clean Please pay attention to the following points when testing this product: ★All screws and components of the installed product must be tightly connected and cannot be rusted; ★The outer casing, lens, fixing parts and installation location (such as ceiling, hanger, truss, etc.) cannot be deformed; ★ The power cord must not be damaged. The installation and use of the product must be carried out by trained professional technicians, and it must be ensured that safety hazards are eliminated. It is important to keep the fixture clean, not only to keep the light output at maximum brightness, but also to extend its service life. It is recommended to use high-quality professional glass cleaner and a soft cloth to clean, any alcohol or chemical solvents is not allowed during the cleaning. The inside of the lamp and the fan should be cleaned by vacuum cleaner at least one time quarterly.

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585

Rashaprofessional.com | [email protected] Notes: