RAB HALV Instructions Manual

Text of the manual

HALV Indoor Architectural-Grade LED Wall Sconce

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected] IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNINGS: • Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. • To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects. CAUTION: • This fixture supports the following protocols – Triac and ELV at 120V ONLY. For 0-10V dimming, connect purple wire to the V+ DIM lead and the grey wire to the V-DIM lead. This fixture is damp listed and suitable for indoor applications on walls. Driver is 120V – 277V and 50Hz or 60 Hz. HALV Mounting the fixture on a standard 4 x 4 J-BOX. This fixture is damp listed and suitable for indoor applications on walls 1. Loosen the (4) driver/LED mounting phillips head screws and separate the driver/LED assembly from the wall plate. No need to remove the screws completely, use the keyhole. DO NOT TOUCH THE LEDs. See Figure 1. 2. Set Driver/LED assembly aside. 3. Pull wires from j-box through the Wall Plate opening and mount Wall Plate to junction box using screws provided with the junction box. Making sure the ‘S’ hook notch is at the top. 4. Hang the Driver/LED Assembly on the ‘S’ hook as shown in Figure 1a. 5. Make wiring connections. Push wire nuts through hole into J box. 6. Replace Driver/LED Assembly making sure not to pinch any wires. 7. Tighten Driver/LED mounting screws. J-BOX WALL MOUNTING (standard models) ‘S’ Hook Notch Wall Plate Driver/LED Assembly DO NOT TOUCH LEDs Driver/LED Screw Keyhole Wire Hole Driver/LED mounting screws ‘S’ Hook FIG.1 ‘S’ Hook ‘S’ Hook FIG.1a

HALV Indoor Architectural-Grade LED Wall Sconce

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected] FIG.3 Wall box is installed before sheetrock. 1. Remove Driver/LED/Wall plate assembly by loosening 4 phillips head screws as shown in Figure 1. No need to completely remove screws, keyhole slots provided. Retain Hanger. Unplug connectors (if E2, E2/MVS, E2, E2/BL, or E2/LC) and put Driver/LED/Wall plate aside. 2. Install Nailer Bars into wall box as shown in Figure 2. 3. Locate the wall box in the desired position between the studs and affix using Nailer Bars. 4. Tighten 1 phillips head locating screw shown in Figure 2 to hold wall box in position on the Nailer Bars. 5. Run wire to box. Wall box is installed after sheetrock. 1. Remove Driver/LED/Wall plate assembly by loosening 4 phillips head screws as shown in Figure 1. No need to completely remove screws, keyhole slots provided. Retain Hanger. Unplug connectors (if E2, E2/MVS, E2, E2/BL, or LC/E2) and put Driver/LED/Wall plate aside. 2. Discard Nailer Bars. 3. Move Stop Brackets from end to side and add Sheetrock Clamps as shown in Figure 3 (on following page). 4. Using the template provided, cut opening in sheetrock. Leave at least ¾” between box and stud. 5. Run wire to box. 6. Place Wall Box in opening and tighten 4 phillips head screws to secure Wall Box. FIG.1 ` FIG.2 Hanger Sheetrock Clamp Stop Bracket after relocation. Move both Stop Bracket screw after relocation Stop Bracket before relocation Stop Bracket screw before relocation Nailer Bar Tighten to secure in sheetrock Hanger Driver/LED/Wall plate assembly DO NOT TOUCH LEDs Insert screwdriver though hole to loosen screw 4 places Hanger Nailer bar Stop Bracket Discard for new work install Tighten this locating screw to hold box in place NEW CONSTRUCTION INSTALLATION (models w/wall box) REMODELER INSTALLATION (models w/wall box)

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected] INSTRUCTIONS HALV Indoor Architectural-Grade LED Wall Sconce CLEANING AND MAINTENANCE TROUBLESHOOTING 1. Use warm water, mild soap and a soft sponge or cloth. Any acrylic cleaner may also be used. Do not use alcohol, glass cleaners, acetone, lacquer thinner, solvents or abrasive compounds. Do not use squeegees, scrapers or synthetic rags that may scratch the panels. a. Lumicor® lenses – Novus® cleaner and polish is an approved product for a clean shine that also protects from static build up. See the “General Polishing & Basic Scratch Repair” document at www.lumicor.com/ScratchRepair for more information. 2. DO NOT OPEN THE FIXTURE TO CLEAN THE LEDs. DO NOT TOUCH THE LEDs. 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. 2. Be sure the fixture is grounded properly. 1. Align Lens Frame over the Driver/LED assembly with the phillips head mounting screw at the top. See Figure 5. 2. Inset the lens frame from the bottom with the bottom flush against the wall. See Figure 5. 3. Tilt the top of the lens frame to the wall. 4. Make sure the frame is flush against the wall and tighten mounting screw at the top using a 5/64” hex key. LENS FRAME INSTALLATION Driver / LED Assembly DO NOT TOUCH LEDs Mounting Screw Lens Frame FIG.5 Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. 1. Hang Driver/LED/Wall plate assembly on Hanger Bracket as shown in Figure 4. 2. Make wire connections. 3. Remove Hanger Bracket and place in bottom of box for future use. 4. Install Driver/LED/Wall plate and tighten 4 phillips head screws. 1. Hang Driver/LED/Wall plate assembly on Hanger as shown in Figure 4 Energize fixture. Mate battery connection. 2. Mate connectors, except for battery connection. Make wiring connections. 3. Energize fixture. Mate battery connection. 4. Remove Hanging Bracket and place in bottom of box for future use. 5. Install Driver/LED/Wall plate and tighten 4 phillips head screws. DRIVER/LED/WALL PLATE/ASSEMBLY (with E2, E2/MVS, E2/BL, or LC/E2 Options) DRIVER/LED/WALL PLATE/ASSEMBLY (with LC option) FIG.4 Hanger

HALV Indoor Architectural-Grade LED Wall Sconce

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected] Easy Answers rablighting.com Visit our website for product info Tech Help Line Call our experts - 888 722-1000 e-mail Answered promptly - [email protected] Free Lighting Layouts Answered online or by request © 2019 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA DIMENSIONAL DRAWINGS LENS FRAME ASSEMBLY (MODELS WITH BACK BOX) LENS FRAME ASSEMBLY (STANDARD MODELS) - HALVLED-IN 0119 RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

19724 MICROWAVE SENSOR FOR D10

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected] IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 19724 is used with a120-277VAC dimmable driver and comes with a sensor antenna. Sensor is shipped with Factory Settings outlined below under DIP Switch Settings. If settings other than factory pre-sets are desired, the consumer may change DIP Switch Settings. For more detailed control of the sensor, the consumer can purchase MVSREM wireless commissioning tool (remote) to re-program sensor settings. SPECIFICATIONS Sensor is not suitable for wet locations. DIP Switch Settings Switch positions referred to as R for right position and L for left position when looking at sensor in orientation shown in Fig. 2, in which all switches are R. See Fig. 1 and 2 for each setting’s corresponding switches. Setting options for each category are noted in (parenthesis) below. Factory Settings: designated in bold for each category Detection Area: Time Delay: how long lamp remains on at 100% after last recognized motion • 100% (RR) • 75% (RL) • 50% (LR) • 10% (LL) • 5s (RRR) • 30s (RRL) • 1min (RLR) • 5min (RLL) • 10min (LRR) • 20min (LRL) • 30min (LLL) Fig. 2 Adjustable Detection Area Time Delay Daylight Sensor Cut Off Period Dim Level Sensor Antenna Interface + - 0-10V L’ N N L DIP Switches Daylight Sensor: Cut Off Period: how long reduced light output lasts after time delay period before fixture switching off Dim Level: light output level after time delay • Disabled (RR) • 5 fc (Daylight) (RL) • 1 fc (Twilight) (LR) • .2 fc (Darkness) (LL) • 0s (RRR) • 10s (RRL) • 1min (RLR) • 5min (RLL) • 10min (LRR) • 30min (LRL) • 1hr (LLR) • Always (LLL) • 10% (RR) • 20% (RL) • 30% (LR) • 50% (LL) L R DIP SWITCHES Factory Settings shown below L’ = driver L = power source Fig. 1 19724 Sensor Antenna

19724 MICROWAVE SENSOR FOR D10

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected] SENSOR COVERAGE DIAGRAM Below diagrams represent best average coverage from lab testing. Actual coverage may vary as metal on the fixtures can interfere with microwaves from the sensor Ceiling mounted detection pattern (m) ceiling mounting height (m) 6 0 5 10% 30% 50% 75% 100% OPERATION Multi-level Dimming: • 100% light • Dimmed to: 10, 20, 30, 50*% *50% not on remote • Off Cut Off Time Adjustment: • Once room is vacated, light dims to selected % after chosen hold time elapses Daylight Sensing: • Surrounding natural light keeps fixture light off until room is occupied and natural light levels drop to selected level 8 Hour* Manual Mode: • Turn fixture off-on 3 times within 3 seconds • Green LED on antenna will flash and fixture will flash 3 times if done correctly • Fixture will remain 100% for 8 hours, then sensor will come on automatically • To cancel, turn the fixture off-on within 1 second *Times out after one 8-hour cycle Ambient Daylight Threshold*: • Turn fixture off-on 2 times within 2 seconds • Green LED on antenna will flash slowly for 5 seconds and fixture will blink twice if done correctly • Surrounding fc will be measured and recorded for 1 second • Green LED on antenna and fixture will light for 10 sec- onds to indicate successful fc recording • Most recent fc measurement overwrites any prior *DIP settings (pg 1) and ambient lux overwrite eachother depending on latest action Scene Mode: • 100% detection range and 10% cut off dimming Scene 1 (SC1): 1 min hold-time, 10 min cut off period, .2 fc daylight sensor Scene 2 (SC2): 5 min hold-time, 10 min cut off period, .2 fc daylight sensor Scene 3 (SC3): 10 min hold-time, 30 min cut off period, 1 fc daylight sensor Scene 4 (SC4): 10 min hold-time, always on bi-level cut off period, 5 fc daylight sensor SENSOR TECHNICAL DATA Capacitance Load: 400W at 120V, 800W at 230V, 1000W at 277V Operating Temperature: -20°C to +60°C (-4°F to +140°F) Relay: Zero-cross relay Maximum Mounting Height: 5m Customizable Detection Area: 10, 50, 75 or 100% Time Delay: 5s, 30s, 1min, 5min, 10min, 20min, 30min Cut Off Period: 0s, 10s, 1min, 5min, 10min, 30min, 1hr, Bi-Level Cut Off Dimming Level: 10, 20, 30, 50% Cut Off Power: Less Than 1W Daylight Threshold: About .2-5 fc or Disabled Sensor Principle: High Frequency Microwave Frequency: 5.8GHz +/- 75MHz Microwave Power: <0.2mW Detection Range Max: 16m across, 10m high Detection Angle: About 30 to 150 degrees 9 0 4 10% 30% 50% 75% 100% Wall mounted height (m) Wall mounted detection pattern (m) Fig. 3 Fig. 4

19724 MICROWAVE SENSOR FOR D10

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected] TROUBLESHOOTING If the sensor does not detect motion as expected: • Check fixture mounting to compare fixture location and sensor coverage with the coverage diagrams on pg 2 • Adjust fixture location as necessary Fixture will not light/sensor does not detect motion: • Make sure ON/OFF button was not selected as this results in disabling the sensor • Check all settings to be sure there is no conflicting selection with the ambient light level Fixture and sensor are too active: • Check detection area setting and reduce coverage as needed • Increase time delay and/or adjust cut off period. Basic Function Overview: REMOTE CONTINUED Detection Range Button Group: assigns detection range of 10, 50 or 100%; use coverage diagrams on pg 2 for guidance. To limit area in which motion will set off sensor, use a smaller percent. The sensor will not detect motion outside of 100% and the fixture will not light. Time Delay Button Group: assigns hold time of 30 seconds, 1 minute, 5 minutes, 10 minutes, or 30 minutes Cut Off Button Group: assigns cut off period of 0 seconds, 10 seconds, 1 minute, 10 minutes, 30 minutes, or 1 hour. 0 seconds gives fixture on/off control rather than dimming. + ∞ keeps the light on always (if daylight sensor is disabled) with Bi-Level dimming control. Dim Level: assigns level of 10, 20, or 30% for dimmed light output after time delay passes Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance. Easy Installation & Product Help Tech Help Line Call our experts 888 RAB-1000 ©2016 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA rabweb.com Visit our website for product info email Answered promptly [email protected] 19724 IN 0616 REMOTE Sensor will beep one time to indicate remote recieved signal successfully Remote settings will override DIP Switch settings ON/OFF: disables sensor; light is permanently* on or off *un-do permanent on/off by selecting either Auto-Mode, RESET, or any Scene mode button Auto Mode: sensor activates and all previously selected settings remain programmed RESET: overrides selected settings; reverts to DIP settings Dim buttons: + dims up and - dims down, adjusting lamp brightness Black Button: no function Test 2s: automatic* test mode with 2 second time delay; disables cut off period and daylight sensor *un-do automatic test mode by selecting either RESET, any Scene mode button, or hold time Power 100% & Power 80%: adjusts power output; to save energy select Power 80%. Must return to full output after initial 10,000 hours of LEDs by pressing Power 100%. Group B: Yellow Sun Button: Ambient Daylight Threshold; records surrounding lux level and overwrites previously recorded value .2, 1 and 5 fc: sets daylight sensor at respective ambient light values Disable: disables daylight sensor; any motion registered by sensor activates fixture light SC1, SC2, SC3, SC4: assigns one of 4 pre-set scenes; see “Operation” on pg 2 for scene descriptions Fig. 5 100% Reduced Level Occupied Time Delay Cut Of Group B Fig. 6

Other Work Light Manuals