Omron KP100G Technical Manual
Text of the manual
Thank you for purchasing the KP100G. This Technical Manual contains essential information regarding functions, performance, and usage of the
KP100G. The KP100G is designed for use in Grid Connected Solar Systems. The installation must always be carried out by qualified personnel with
knowledge of electrical systems and according to national standards for electrical installations.
The software and the protective functions are not accessible and/or changeable to the user.
Please read this manual carefully and make sure that you understand it well to ensure that you are using the KP100G correctly. Keep this manual in a
safe location so that it is available for reference when required.
Make sure that you read the items in the following table, and follow the instructions therein.
Page
For Users
For Installers and
Other Specialists
1
Introduction
2
YES
YES
2
Model Name
9
YES
YES
System Description
10
YES
YES
MPP Trackers
11
YES
YES
Disconnecting from the Grid (ENS)
11
YES
YES
3
Conditions for Disconnecting from the Grid
12
YES
YES
4
Parts Names
13
YES
YES
Installation
15
YES
Mounting
15
YES
Package Contents
15
YES
Mounting Dimensions
16
YES
Mounting Procedure
17
YES
Install the Data Logger independently
21
YES
Wiring
22
YES
Plug Processing
22
YES
Connecting to the Grid
28
YES
Preliminary Confirmations
28
YES
Wiring the KP100G to the Solar Modules
29
YES
5
Completion Inspection
30
YES
The setting in the case of particular countries
31
YES
6
The setting in Italy (KP100G-OD-IT)
31
YES
7
Display
33
YES
YES
System Monitoring
38
YES
YES
Data Communications
38
YES
YES
RS-485 Communications
38
YES
YES
Data Logger
40
YES
YES
RS-232C Communications
40
YES
YES
8
LCD(Data Logger) Messages
41
YES
YES
9
Technical Data
44
YES
YES
Maintenance
45
YES
YES
Additionally tighten the tightening cap
45
YES
YES
10
Others
45
YES
YES
11
Troubleshooting
45
YES
YES
12
Meanings of Error Messages and Their Remedies
46
YES
YES
13
Other Information
48
YES
YES
14
Appendix
49
YES
YES
15
After-sales service
54
YES
YES
16
Contact address
54
YES
YES
Please read and understand this manual before using the product. Please consult your dealer if you have any questions or
comments.
Safety Precautions · Definition of Precautionary Information
The following notation is used in this manual to provide precautions required to ensure safe usage of the KP100G Gridconnect Photovoltaic Inverter
(hereafter called the KP100G). Always read and heed the information provided in all safety precautions.
WARNING
Indicates a potentially hazardous situation which, if not avoided, is likely to result in serious injury or
may result in death. Additionally there may be severe property damage.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury or in property damage. Property damage refers to damage that may extend to include the house,
furniture, and pets.
Meanings of Alert Symbols
Disassembly Prohibition
Indicates prohibitions when there is a possibility of injury, such as from electric shock, as the result of
disassembly.
High-temperature Caution
Indicates the possibility of injury by high temperature under specific conditions.
General Prohibition
Indicates non-specific general prohibitions.
General Instruction
Indicates non-specific general instructions for user actions.
Electric Shock Caution
Indicates the possibility of electric shock under specific conditions.
Ground Wire Connection
Used to instruct the user to always connect the ground wire when using a device equipped with a safety
ground terminal.
Disposing Caution
Used to instruct the user to follow the specified procedure when disposing the product.
Important Safety Descriptions
Observe the following warnings and cautions when using the KP100G.
� Important user information:
WARNING
CAUTION
Injury due to electric shock, or fire, may possibly
occur. Do not open the front cover or
disassemble, modify, or repair.
Burn injury will occur. Do not touch the upper part
of the product cabinet during operation or
immediately after stopping operation.
Significant injury may possibly occur due to fire.
Do not use the product in a flammable gas
atmosphere (including flammable sprays such as
pesticides).
Fire will occur. Do not obstruct ventilation holes or
place any objects within 20 cm of the ventilation
holes.
Fire will occur. Do not install near highly
combustible items or heat sources (stoves,
heaters, boilers, etc.).
Injury due to electric shock or property damage due
to burning may occasionally occur. Do not remove the
MC connector, the AC output cover, RS-485
protection cover, and the RS-232C protection cover.
Do not unfasten of cable gland of AC output and RS-
485.
Significant property damage may occasionally
occur. Do not use the product at any country
other than the designated one.
Output power may be restricted due to ventilation
obstruction. Clean the ventilation holes on top and
bottom regularly.
Injury or electric shock will occur. Read the
manual and follow prior to using the product,
and follow the instructions carefully.
Electric shock or fire will occur. Have an installer
from the store where you purchased the product,
or an authorized service person, install, repair,
modify, add on, move, or reinstall the product.
Death may possibly result due to injury because
the PV module operates at a high voltage. Do not
remove the connector except for the instruction of
the manual.
Ask the store from which you purchased the
product or an authorized person to dispose of it
when it is no longer needed
Precautions for Correct Use
Do not stand on the product and Data Logger or place any objects on it.
Important installer information:
WARNING
CAUTION
Injury due to electric shock, or fire, may possibly
occur. Do not open the front cover or disassemble,
modify, or repair.
Burn injury will occur. Do not touch the upper part
of the product cabinet during operation or
immediately after stopping operation.
Functional impairment may possibly occur due to
the destruction or damage of internal components
caused by condensation. Do not install in places
subject to high humidity, steam, or high
temperatures.
Fire will occur. Do not obstruct ventilation holes or
place any objects within 20 cm of the ventilation
holes.
Significant injury may possibly occur due to fire.
Do not use the product in a flammable gas
atmosphere (including flammable sprays such as
pesticides).
Damage from burning will occur. Turn OFF the AC
breaker before removing the MC connector. Do not
connect or disconnect the MC connector while the
current is flowing.
Injury or functional impairment may possibly
occur due to electric shock or burns. Do not install
in places that are within the reach of children.
Injury may occasionally occur.
Be careful by two persons when for transporting
and placing in position.
Fire will occur. Do not install near highly
combustible items or heat sources (stoves, heaters,
boilers, etc.).
Confirm the polarity of the cable from the PV
module and the AC side to ensure correct
connection and avoid possible damages which are
not covered by warranty. This can be done with a
standard Multimeter.
Significant property damage may occasionally
occur. Do not use the product at any country other
than the designated one.
Injury will occur due to the product falling. Install
the product in a location that will be able to support
its weight (35 kg). The installation location must be
able to withstand the force of 185 N•m of torque at
each mounting screw.
Injury or electric shock will occur. Read the
manual and follow prior to installing or performing
maintenance on the product, and follow the
instructions carefully.
Injury will occur due to the product falling. Use the
installation parts and materials that are included
with the product.
Have the installation done by a person with
qualifications approved by the relevant local utility.
IP65 performance may not be provided, if you
don’t follow these instructions:
1. Tighten the cable glands of AC output and RS-
485.
Injury due to electric shock or property damage due
to burning may occasionally occur. Mount the
enclosed caps onto MC connector that is not used.
Mount the rubber bushing with no hole in RS-485
connector if RS-485 is not used. Tighten the screw of
RS-232C protection cover properly if RS-232C is
not used.
2. Use a wire with a cross-sectional area of 4 mm2
or AWG12 and a cable with diameter of 6 mm is
allowed for the AC connector. Use a wire with a
cross-sectional area of 10 mm2 or AWG8 is a cable
with diameter of 7.5 to 15 mm allowed for GND
connector.
3. Tighten the screws of the AC output over and RS-
232C and RS-485 protection cover to the specified
torque (1.3 to 1.6 N•m). Or tighten the screws of RS-
232C connecter properly.
4. Some thinning of the cable may be caused due to
usage conditions, with the result that IP65
performance may not be provided. Perform
additional tightening of the tightening cap of AC
cover and communication cover regularly.
5. Tighten the tightening cap of communications
cover to the specified torque.
6. Use a wire with a cross-sectional area of 0.3 mm2
and a cable with diameter of 4 mm is allowed for
the communications plug.
7. Tightly tighten the screws of plug with Data
Logger.
Death may possibly result due to injury because the
PV module operates at a high voltage. Be extremely
careful when handling the MC connector.
Electric shock will occur. Doing AC wiring work
during Turn OFF the AC breaker before
connecting the MC connector.
Electric shock will occur. Do not touch the DC plug
or MC connector for at least 3 minutes after
turning OFF the AC breaker and disconnecting the
MC connector.
Electric shock will occur. Be sure to connect the
ground wire.
Precautions for Safe Use
Be sure to observe these precautions to ensure safe use of the product.
(1) Do not install in locations subject to saltwater spray, such as on oceangoing vessels or near a seacoast.
(2) Do not install near equipment, such as a radio or TV, that is likely to be affected by electric waves, or near an antenna.
(3) Turn OFF the AC breaker before doing any wiring work.
(4) When installing outdoors, be sure to provide an awning or eave of some kind to prevent direct sunlight or rain from striking the Unit.
(5) Leave space of 20 cm minimum between the Unit and the ceiling or eave, 20 cm minimum between the Unit and the floor or ground,
and 20 cm minimum between the Unit and right or left wall.
(6) When installing multiple KP100G Inverters, leave a space of 20cm minimum to the side of each Inverter. Do not install multiple
Inverters vertically.
(7) Mount the Inverter in the specified direction.
(8)Functional impairment may possibly occur due to the destruction or damage of internal components caused by dropped the Data
Logger. Be extremely careful when handling the Data Logger by installing it.
(9) Use appropriate wire for the capacity of the solar modules. A standard wire with a cross-sectional area of 4 mm2 or 12AWG is
allowed for the AC wires.
(10) Be sure to inspect the system before doing a trial operation.
(11) Use an AC breaker that matches either the B trip characteristics.
(12) Use appropriate breaker for the capacity of the solar modules.
(13) Use a 20 A trip breaker for the AC breaker.
(14) When connecting to an AC connector cover or MC connectors, make sure that there is no slackness.
(15) Do not connect solar cells that have an open-circuit voltage in excess of 800 VDC.
(16) Tighten the screws of the AC output terminal of L1,L2,L3,N to the specified torque (0.8 to 1.0 N•m).
Tighten the screws of the AC output terminal of G to the specified torque (2.0 to 2.5 N•m).
(17) Use the recommended contact, or an equivalent one, for wiring to the AC connection.
(18) When wiring to the AC connection, do not put two or more wires into one wire insertion opening.
(19) Omron KP100G PV Inverter shall be installed and used properly in a way to keep away from the following incidents
a) altered or repaired, maintained or overhauled except by OMRON or any person expressly authorized by OMRON, without prior
written consent of OMRON
b) use of parts or accessory other than OMRON specify
c) defect caused by circumstantial factors such as wiring or peripheral equipment to be connected
d) pro-longed mechanical stress; eg. Tiny but continuous vibration for a long period
(20) Omron KP100G PV inverter shall be installed and used properly in a way to prevent the following possible incidents;
a) Lightening surge; easier to penetrate into a PV inverter by conducting on lines between PV modules and PV inverters comparing to
other apparatus installed in the house like a washing machine and may result in a breakage of PV inverter
b) Surge noise (spike) caused by a nearby construction work; flow into a PV inverter and may result in a breakage
c) Grid instability caused by a nearby construction work; make voltage variation larger and cause a malfunction, it may result in a
claim to replace the product
d) Nearby plant (under a poor grid connection); make voltage and/ or frequency vary too largely to activate an error (message), as it
happens repeatedly the customer starts suspecting the quality or defect of the product and it may result in a claim to replace the
product
e) Home apparatus without grounding (eg. washing machine); make a noise to a PV inverter from time to time and it may result in a
breakage
f) Installation circumstances that cause internal relays of PV inverter to repeat switching on and off; it may result in a welded contact
before its life time. It should be a set up that is good at making a balance of startup and stop of PV modules.
g) Characteristics matching with PV modules (as a PV system); amorphous PV modules cause leakage current detector to be
erroneously activated when it is set up, in rain, or as time goes by, and shut down a PV inverter, and it may result in a claim to
replace the product.
Precautions for Correct Use
(1) Observe the following precautions when installing and storing the product.
a) Protect the wiring by, for example, placing it inside wiring ducts if there is a possibility that it may be damaged by animals or other
factors.
b) Protect the product from falling snow, accumulated snow, or wind-blown snow by building a protective roof over it when installing
the product in a snowy region.
c) Provide sufficient safety measures, such as scaffolding, to prevent danger during installation work.
d) Store in a place where the temperature is within the range of −25 to 60°C (with no condensation or icing), and the humidity is 95 %
maximum.
e) Store in a place that is no more than 2,000 m above sea level.
(2) Do not use this product in the following places:
a) Places subject to intense temperature change.
b) Places subject to volatile, flammable, corrosive, or other toxic gas.
c) Places subject to vibration and large shocks.
d) Places subject to water vapor, oil vapor, or condensation.
e) Places where the main body may be immersed in water.
f) Places subject to electric fields, direct sunlight, poor ventilation(ex. Narrow places where the ventilation would be obstructed or the
ambient temperature conditions would be exceeded.), considerable dust, many small insects.
g) Places subject to temperature and humidity conditions outside of the following ranges.
·Temperature: −20 to 55°C
·Humidity: 4 to 100 %
h) Places more than 2,000 m above sea level.
i) Narrow places where the ventilation would be obstructed or the ambient temperature conditions would be exceeded.
(3) Omron KP100G PV Inverter shall be installed and used properly in a way to keep away from the following incidents
a) altered or repaired, maintained or overhauled except by OMRON or any person expressly authorized by OMRON, without prior
written consent of OMRON
b) use of parts or accessory other than OMRON specify
c) defect caused by circumstantial factors such as wiring or peripheral equipment to be connected
d) pro-longed mechanical stress; eg. Tiny but continuous vibration for a long period
(4) Omron KP100G PV inverter shall be installed and used properly in a way to prevent the following possible incidents;
a) Lightening surge; easier to penetrate into a PV inverter by conducting on lines between PV modules and PV inverters comparing to
other apparatus installed in the house like a washing machine and may result in a breakage of PV inverter
b) Surge noise (spike) caused by a nearby construction work; flow into a PV inverter and may result in a breakage
c) Grid instability caused by a nearby construction work; make voltage variation larger and cause a malfunction, it may result in a
claim to replace the product
d) Nearby plant (under a poor grid connection); make voltage and/ or frequency vary too largely to activate an error (message), as it
happens repeatedly the customer starts suspecting the quality or defect of the product and it may result in a claim to replace the
product
e) Home apparatus without grounding (eg. washing machine); make a noise to a PV inverter from time to time and it may result in a
breakage
f) Installation circumstances that cause internal relays of PV inverter to repeat switching on and off; it may result in a welded contact
before its life time. It should be a set up that is good at making a balance of startup and stop of PV modules.
g) Characteristics matching with PV modules (as a PV system); amorphous PV modules cause leakage current detector to be
erroneously activated when it is set up, in rain, or as time goes by, and shut down a PV inverter, and it may result in a claim to
replace the product.
2. Model Name
The following KP100G models are available.
Table 2-1 Model Name
Model
ENS Availability
Country
KP100G-OD-DE
With ENS
Germany
KP100G-OD-ES
Without ENS
Spain
KP100G-OD-IT
Without ENS
Italy
3. System Description
The KP100G converts DC power obtained from solar modules into the AC power that is used in homes and businesses, and enables interconnection
with the utility grid.
This makes it possible to purchase power from the utility during periods when the load is high, and to sell power to the utility during periods when the
load is low. (Please note that a contract must be concluded with the utility for this purchasing and selling transaction.) The system configuration of the
KP100G is shown in Fig, 3-1.
Fig, 3-1 System configuration of KP100G
MPP (Maximum Power Point) Trackers
Three pairs of positive and negative DC input channels are connected to three sets of MPP Trackers.
DC Bus
The three sets of MPP Trackers store DC power via the DC/DC boost converter to the DC bus
DC/AC Inverter
The DC bus is connected to the DC/AC inverter, which converts DC power to AC power
Main and Redundant Relays
The two relays, RLY1 and RLY2, control the connection of the inverter to grid via the main and redundant controllers.
Output Lines
Three output lines (L1, L2, and L3) represent the three-phase AC power transmission to grid.
Other Main Components
The EMI Filter, GFCI, System Power Supply, Riso, Interface, and Display are included.
EMI Filter
EMI Filter
System
Power
Main Controller
Redundant
Controller
Interface
RS-485, RS-232C
Display
GFCI
MPP Tracker 1
+
+
MPP Tracker 2
MPP Tracker 3
PV1+
PV1-
PV2+
PV2-
PV3+
PV3-
DC/AC Inverter
L1
L2
L3
N
PE
L V
VAC
VOU
ACI
BUS_V
Riso
DCI
DCV
RLY1
RLY2
Vdc1, Vdc2, Vdc3
Idc1, Idc2, Idc3
BUS_V
Iac1, Iac2, Iac3
GFCI_V
Vac1, Vac2, Vac3
Vout1,Vout2,Vout3
The output power of the PV array varies depending on the intensity of the incident light and the temperature of the modules. In order to use the unstable
output of solar modules efficiently, the KP100G searches for the operating voltage that will produce the maximum output while it converts the DC input
voltage.
The KP100G has three MPP trackers. The topology of the MPP Trackers is mainly a boost converter. Each boost converter steps up the DC input
voltage to a higher DC BUS voltage.
User can connect differently-aligned string as three MPP trackers operate independently as illustrated in Fig, 3-2. This construction achieves high power
generation and flexible sizing of PV string.
Fig, 3-2 Connection of differently-aligned string
Disconnecting from the Grid (ENS)
(Einrichtungen zur Netzueberwachung mit jeweils zugeordnetem Schaltorgen)
When the utility disconnects part of its grid for maintenance, repairs, etc., it is necessary to ensure that the personnel working there are not in danger of
being injured. For this purpose, a new safety concept was added to the VDEW regulations proposed by Berufsgenossenschaft fuer Feinmechanik und
Elektrotechnik (German Employee Association of Precision Mechanics and Electronics Engineering).
The KP100G-OD-DE is designed exclusively for grid-connected operation. It is equipped with a fully independent disconnection device to ensure safe
and complete breaking, and to prevent islanding operation, when the grid is disconnected.
This independent disconnection device is comprised of two ENS units connected in series for safety. Each of the ENS units checks the frequency,
voltage, in order to provide constant monitoring of the grid. A redundant circuit and auto-diagnosis when each system is started further improves the
reliability of the disconnection function.
Input specifications:
a) DC input voltage range: 200 to 800VDC
b) MPPT voltage range: 300 to 800VDC
Input limitations:
a) Maximum input open-circuit voltage: 800VDC
b) Maximum input current per Tracker: 13ADC
MPP tracker controls not to exceed 13ADC.
c) Maximum input power per Tracker: 5,500W
MPP tracker controls not to exceed 5500W.
PV1
PV2
PV3
+
-
+
-
+
-
+3
+2
+1
-3
-2
-1
DCP
DCV
DCP
DCV
DCP
DCV
Conditions for Disconnecting from the Grid
Grid Voltage
When the grid voltage varies from the ranges listed in Table 3-1, the KP100G disconnects from the grid.
Table 3-1 Conditions UV/OV of the KP100G
Model
Country
UV (AC Undervoltage)
OV (AC Overvoltage)
KP100G-OD-ES
Spain
196VAC
253 VAC
KP100G-OD-IT
Italy
191 VAC
264 VAC
253 VAC within 10min (See Note)
KP100G-OD-DE
Germany
196 VAC
264 VAC within 0.2sec (See Note)
Note: According to VDE0126-1-1 4.2.2, when grid voltage exceeds 115%UN, the KP100G must disconnect from grid within 0.2sec.
According to VDE0126-1-1 4.2.3, the KP100G monitor grid voltage in 10min interval, and when grid voltage exceeds
100%UN in 10min, the KP100G disconnect from grid.
Grid Frequency
When the grid frequency varies from the ranges listed in Table 3-2, the KP100G disconnects from the grid.
Table 3-2 Conditions UF/OF of the KP100G
Country Setting
UF (Under frequency )
OF (Over frequency)
KP100G-OD-ES
Spain
49.0 Hz
51.0 Hz
KP100G-OD-IT
Italy
49.7 Hz
50.3 Hz
KP100G-OD-DE
Germany
47.5 Hz
50.2 Hz
ENS standards require that each model be tested by a third-party verification institute, and that all ENS units be tested prior to shipping. To ensure
that switching devices (relays) operate properly, always do an operational check before starting up the KP100G. If the test results are negative, the
KP100G will repeat the self-diagnostics. If the problem remains, it will be necessary to have a specialist diagnose it. Malfunctions are indicated by the
LCD.
4. Parts Names
Fig, 4-1 Parts names
(1) Air Cooling Fan: 3 force air cooling fans to dissipate heat produced by the inverter. When temperature reaches 50 °C, air cooling fans will switch
on automatically by inverter and three fans will start operating simultaneously. In the meantime, air cooling fans will dissipate heat from inside of
the inverter to outside or top to down direction.
Fig, 4-2 Cooling fans
(2) 3 pairs of DC-input terminals (MC-connectors): Each input pair consists of positive and negative terminals. Refer to Installation Section for set-
up information.
Fig, 4-3 DC-input terminals
3 Cooling Fans
Data Logger
RS-485
communication port
AC Output
RS-232C connector
3 Fans
Heat sink
3-pairs of DC
input
(3) AC Output and GND: Delivering AC to the Public Utility.
Fig, 4-4 AC output terminals
(4) RS-485 communication interface: Interface allows communication with computer via RS-485. The port is protected by a water-proof cover.
Fig, 4-5 RS-485 communication interface
(5) RS-232 communication interface: Interface allows communication with computer via RS-232C serial.
Fig, 4-6 RS-232 communication interface
(6) LCD (Data Logger): Device to display and record inverter operation status.
Fig, 4-7 Data Logger
AC output plug
GND plug
RS-485 Communication
Interface
Use the following procedure to install the Unit.
Table 5-1 Installation Procedure
No.
Item
Procedure
Reference Page
1
Checking package contents
Check to make sure that all of the items listed on the reference
page are included in the package.
15
2
Mounting the base plate
Use the enclosed mounting screws to mount the base plate to the
wall, according to the procedure described on the reference page.
19
3
Mounting the Unit
Mount the KP100G to the base plate, according to the procedure
described on the reference page.
20
4
Processing the plugs
Follow the procedures on the reference pages to process the
communications plug and AC plug.
22
5
Wiring the Unit
Wire the KP100G to the grid, and to the solar modules, as
described in Fig, 5-34 and Fig, 5-35 on the reference page.
28
6
Preliminary Confirmations
Execute the preliminary confirmation according to the procedure
described on the reference page.
28
7
Completion Inspection
Conduct the completion inspection according to the procedure
described on the reference pages.
30
Mounting
Package Contents
The following items are included in the KP100G package. Check that all of the items shown in the following are included in the package before you
start the installation.
KP100G, Mounting base plate, Technical Manual
Fig, 5-1 KP100G, Mounting base plate, Technical manual
Enclosed mounting screws
6 Mounting Screws 6 Snap Bushings 2 Safety-lock screws
Fig, 5-2 Enclosed mounting screws
For connection of AC cable For connection of RS-485 cable
Fig, 5-3 Rubber Bushing
Securing plate and screws for removable data logger
Securing plate screws
Fig, 5-4 Securing plate and screws
MC caps (-), MC caps (+)
Fig, 5-5 MC caps
Mounting Dimensions
Fig, 5-6 Mounting dimensions (Unit: mm)
� Safety Precautions
(1) Do not install the Unit on ocean-going vessels or in places near the seacoast that are subject to saltwater spray.
(2) When installing outdoors, be sure to provide an awning or eave of some kind to prevent direct sunlight or rain from
striking the Unit.
(3) Leave space of 20 cm minimum between the Unit and the ceiling or eave, 20 cm minimum between the Unit and the floor or ground,
and 20 cm minimum between the Unit and right or left wall.
Fig, 5-7 Mounting conditions 1
(4) When installing multiple Inverters, leave a space of 20 cm minimum to the side of the Inverter. Do not install multiple Inverters
vertically.
Incorrect
Fig, 5-8 Mounting conditions 2
(5) Mount the Inverter in the specified direction.
Mount Inverter straight Never mount tilted to front
Fig, 5-9 Mounting conditions 3
20 cm
20 cm
20 cm
20 cm
20 cm
(6) Omron KP100G PV Inverter shall be installed and used properly in a way to keep away from the following incidents;
a) altered or repaired, maintained or overhauled except by OMRON or any person expressly authorized by OMRON, without prior
written consent of OMRON
b) use of parts or accessory other than OMRON specify
c) defect caused by circumstantial factors such as wiring or peripheral equipment to be connected
d) pro-longed mechanical stress; eg. Tiny but continuous vibration for a long period
(7) Omron KP100G PV inverter shall be installed and used properly in a way to prevent the following possible incidents;
a) Lightening surge; easier to penetrate into a PV inverter by conducting on lines between PV modules and PV inverters comparing
to other apparatus installed in the house like a washing machine and may result in a breakage of PV inverter
b) Surge noise (spike) caused by a nearby construction work; flow into a PV inverter and may result in a breakage
c) Grid instability caused by a nearby construction work; make voltage variation larger and cause a malfunction, it may result in a
claim to replace the product
d) Nearby plant (under a poor grid connection); make voltage and/ or frequency vary too largely to activate an error (message), as it
happens repeatedly the customer starts suspecting the quality or defect of the product and it may result in a claim to replace the
product
e) Home apparatus without grounding (eg. washing machine); make a noise to a PV inverter from time to time and it may result in a
breakage.
f) Installation circumstances that cause internal relays of PV inverter to repeat switching on and off; it may result in a welded contact
before its life time. It should be a set up that is good at making a balance of startup and stop of PV modules.
g) Characteristics matching with PV modules (as a PV system); amorphous PV modules cause leakage current detector to be
erroneously activated when it is set up, in rain, or as time goes by, and shut down a PV inverter, and it may result in a claim to
replace the product.
(8) Choosing the location
During certain operation phases the KP100G PV inverter may develop a slight noise level, for this reason it should not be
installed in the place where a slight audible noise is not permitted.
(1) Mark the positions of the 4 outer mounting holes onto the wall with the bracket as illustrated in Fig, 5-10.
To install the device to a narrow upright, mark the 4 central holes at the back of the bracket as illustrated in Fig, 5-11.
Fig, 5-10 Mounting holes
Fig, 5-11 Mounting holes to install the device to a narrow upright
Upper mounting holes
Lower mounting holes
Mounting
base plate
Upper central
mounting holes
Lower central
mounting holes
(2) Drill the 4 marked holes in the wall, and then drive in the 4 Snap Bushings. Now insert the screws, and tighten.
Outer Mounting Holes Central Mounting Holes
Fig, 5-12 Mounting the base plate
(3) Mount the PV-Inverter onto the base plate as illustrated:
Fig, 5-13 Mount the KP100G onto the base plate
(4) Insert the Safety Lock screws to fix the PV-Inverter in place.
Safety-lock screw
Safety-lock screw
Install the Data Logger independently
The data logger can be easily detached and be installed in the wall.
(1) To detach the data logger, push the side of it and pull out.
Fig, 5-14 Detach the securing plate
(2) Insert 2 screws and tighten to attach the securing plate to data logger.
Fig, 5-15 Attach the securing plate
(3) Drill 2 holes in the wall, and then drive in the 2 Snap Bushings. Now insert the screws and tighten to fix data logger in place.
Fig, 5-16 Install the Data Logger
Securing plate
Push and pull out
IP65 performance may not be provided, if you don’t follow these instructions:
1. Tighten the cable glands of AC output and RS-485.
2. Use a wire with a cross-sectional area of 4 mm2 or AWG12 and a cable with diameter of 6 mm is allowed for the AC connector.
Use a wire with a cross-sectional area of 10 mm2 or AWG8 is a cable with diameter of 7.5 to 15 mm allowed for GND connector.
3. Tighten the screws of the AC output over and RS-232C and RS-485 protection cover to the specified torque (1.3 to 1.6 N•m). Or
tighten the screws of RS-232C connecter properly.
4. Some thinning of the cable may be caused due to usage conditions, with the result that IP65 performance may not be provided.
Perform additional tightening of the tightening cap of AC cover and communication cover regularly.
5. Tighten the tightening cap of communications cover to the specified torque.
6. Use a wire with 0.3 mm2 is and a cable with diameter of 4 mm allowed for the communications plug.
7. Tightly tighten the screws of plug with Data Logger.
Connecting the AC Output Cable
Connect your PV-Inverter to the AC Connection unit via the AC output cable as following steps:
Fig, 5-17 Wiring the KP100G to the grid
(1) Open the AC output cover with a screw driver.
Fig, 5-18 Open the AC output cover
AC connection unit
(Consisting of
breaker, fuse,
terminals etc.)
AC Output Connector
AC Output cable
(4mm2 or AWG12)
GND cable
(10mm2 or AWG 8)
Grid
AC output cover
Cable glands
(2) Unscrew the cable gland and prepare AC and Ground(GND) cable. Remove the rubber bushing from inside the AC connector socket.
Fig, 5-19 Remove the rubber plug
(3) Insert the provided rubber bushing into the AC connector socket.
Two types of rubber bushing for AC connection as illustrated in Fig, 5-3.
� The rubber bushing with 4 holes is used for connection with 4 individual cables.
� The rubber bushing with 1 hole is used for connection with multiple-cable.
Rubber sealing for GND cable is already inserted inside of connector.
Now insert the four wires of the AC cable and one wire of GND cable into the bushing holes.
Please note that cross-sectional area of 4 mm2 is allowed size for AC wires; L1, L2, L3, N, and that a cross-sectional area of 10 mm2 or AWG8 is
allowed for GND.
Fig, 5-20 Insert the rubber bushing with holes
(4) Fix 4 wire to L1 (R), L2 (S), L3 (T), and N (Neutral), and a wire to G (Ground).
Fig, 5-21 Connect the AC wire
Rubber bushing (no hole)
2 types rubber bushings for
AC connector
Rubber sealing for GND
connector
(5) After checking the 5 wires are fixed properly, push the AC output connection set back in to the Connection Panel. Drive 5 screws back to fix the set.
Fig, 5-22 Set the AC output cover
(6) Now screw on the cable glands to lock the bushing and cable together.
Fig, 5-23 Screw on the Connector glands
Processing the Communication Cable
RS-485
KP100G has RS-485 as a standard interface. The RS-485 card enables the multi-inverter connection solution. The card is a half-duplex with 2-wires,
one for each inverter connection. The steps for processing the RS-485 are as follows. When the RS-485 card is inserted, the RS-232C port is not
available.
Processing the communication cable of RS-485
Fig, 5-24 Installation of RS-485 card
RS-485 is installed in KP100G as a standard. To use RS-485 cards, please:
1. Remove the protection cover as shown in Fig, 5-25 (a). Remove screws, and pull out the fixed plate and RS-485 card.
(a) (b)
Fig, 5-25 Remove the protection cover and fixed plate
2. Prepare 2 pairs of shielded, twisted-wires for connection between the inverter and computer or between inverters. Fix the wires as shown before
insertion of the cards as shown in Fig, 5-26.
Two types of rubber bushing for RS-485 connection as illustrated in Fig, 5-3.
� The rubber bushing with 2 holes should be used for connection of multiple inverters.
� The rubber bushing with 1 holes should be used for connection of single inverter or last one inverter of multiple connected inverters.
Fig, 5-26 Fix the wire prior to insertion of the card
Fixed plate
Protection cover
Slide in to install.
Pull out to remove.
Fig, 5-27 Instruction of for wiring of terminal of RS-485 card
3. Slide the card into the slot as shown in Fig, 5-28.
Fig, 5-28 Sliding the card into the slot
4. Fix the card with 2 screws as shown in Fig, 5-29.
Fig, 5-29 Lock on the screws
5. Fix the protection cover with 4 screws as shown in Fig, 5-30.
Fig, 5-30 Fix the protection cover
Fixed plate
R- R+ T- T+
R- R+ T- T+
N.C. N.C.
N.C. N.C.
Terminal of RS-485 card
Connect to RS-485 interface of
another inverter
Connect to RS-485 interface of
another inverter
N.C. means “No Connection
If the RS-485 card is inserted, RS-232C is not available. To use RS-232C interface, remove RS-485 card.
The RS-232C interface has a protection cover, which can be unbolted and removed with a screwdriver as shown in Fig, 5-31 and. Fig, 5-32.
Fig, 5-31 RS-232C interface Fig, 5-32 Socket available for RS-232C connection
KP100G uses a DB9 socket for the RS-232C interface. Remove the DB9 socket cover before use. The pin assignment of this DB9 socket is listed
In.Table 5-2.
Table 5-2 Pin assignment
Pin
Signal Assignment
1
N.C.
2
TxD
3
RxD
4
N.C.
5
Common
6
N.C.
7
N.C.
8
N.C.
9
N.C.
N.C. means “No Connection
Fig, 5-33 Female connector
Remove
these screws
5 4 3 2 1
9 8 7 6
Female
Side
Connecting to the Grid
Wiring the KP100G to the Grid
The AC connection unit is an interface between PV-Inverter and the Public Utility. It may consist of an electrical breaker, fuse and terminals for
connection to both PV-Inverter and the Public Utility. This AC connection unit must be designed by qualified technician to comply with local safety
standards.
Use a 20 A trip AC breaker that matches the B trip characteristics.
Fig, 5-34 Wiring the KP100G to the grid
Preliminary Confirmations
Check the following items before wiring.
Table 5-3 Preliminary Confirmations
No.
Inspection Item
Measurement or Confirmation
Check mark
1
Solar module installation
condition
Visual confirmation:
Refer to the installation manual for the solar modules.
2
KP100G installation condition
Visual confirmation:
Make sure none of the mounting screws are loose.
Make sure that the KP100G and the mounting base plate are securely fixed with the
main body mounting screw.
3
Wiring, connection, and
conductivity
Visual confirmation:
Inspect for looseness in plugs and screws, proper wire connection, and conductivity.
4
KP100G ground resistance
Measurement confirmation:
Standard: 100 Ω max.
KP100G actual measurement: Ω
5
Voltage measurement for each
solar module string
(See Note 1.)
Measurement confirmation: V
Measure to confirm that the grid voltage is 230 V.
6
Grid voltage confirmation
Actual measurement: V
Note 1: The output voltage of the solar modules varies depending on their type and the number connected in series. Confirm that the voltage difference
between adjacent strings is within the range of several volts.
AC connection unit
(Consisting of
breaker, fuse,
terminals etc.)
AC Output Connector
AC Output cable
(4mm2 or AWG12)
GND cable
(10mm2 or AWG8)
Grid
Wiring the KP100G to the Solar Modules
� First make sure the maximum open circuit voltage Voc of each PV string is below 800VDC under any condition.
� Always connect PV-Panel positive (+) terminal to PV-Inverter DC positive (+) terminal, and the PV-Panel negative (-) terminal to PV-Inverter DC
negative (-) terminal.
� KP100G has 3 MPPT trackers. Usually PV-Panels are connected to 3 DC terminals as illustrated in Fig, 5-35(a).
Each set of PV-Inverter DC terminals takes a maximum DC input of 13A. As a result, 3 pairs of PV-Inverter DC terminals can take a combined
input of up to 39A.
Maximum PV input power for each tracker is 5,500W.
� One PV-panel can be connected to 3 DC input as illustrated in Fig, 5-35(b) .
To fully optimize the PV output set-up, use the following configuration guidelines:
(a) For PV output less than 13A, use a single pair of PV-Inverter DC terminals.
(b) For PV output between 13A and 26A, use two sets of inverter DC terminals.
(C) For PV output between 26A and 39A, use three sets of inverter DC terminals.
(a) 3 Panel Strings (under 39A) (b)1 Panel String (between 13A and 39A)
Fig, 5-35 Wiring the KP100G to the solar modules
Be especially careful about electric shocks during the daytime, because that is when the solar modules are in the power generating mode. Confirm the
polarity of the cable from the PV module to ensure correct connection and make sure that there is no slackness of MC connectors.
PV1 under 13A
PV2 under 13A
PV3 under 13A
+
-
+
-
+
-
+3
+2
+1
-3
-2
-1
PV-panel
+
-
+3
+2
+1
-3
-2
-1
Table 5-4 Completion Inspection
No.
Inspection Item
Procedure
Reference
Page
Check
mark
1
High voltages exist when the PV-Panel is exposed to the sun. Exposed
terminals of the PV-Panel are live, and can cause electric shock. Avoid
making physical contact with live parts of the device.
---
2
Connect the PV-
panels
After the PV-Panels are connected to the PV-Inverter, the output voltage is
greater than 200VDC and the AC grid is not connected to the inverter, the
Data Logger LCD displays.
35
Step 1:
Check the connection between your PV-Inverter and AC Connection System.
And then check the connection between the Public Utility and AC Connection
unit.
Close the AC breaker or fuse in the unit.
28
Step 2
Measure the time until operation resumes. (The power-ON delay time varies
depending on the country. Refer to Table 5-5)
30
3
Power-ON delay time
for grid-connected
operation
(See Note 1.)
Step 3
Confirm that the Data Logger LCD displays the status “Normal” and that the
KP100G performs the grid-connected operation.
The PV-Inverter is feeding power to the grid, and the green LED displays.
34
4
Confirm the
wattmeter
The Wattmeter installed to count the injected electricity should work while
the inverter displays that electricity is being injected.
-
Note 1 : The power -ON delay time is the time that it takes for the KP100G to resume operation after the power supply of the supply side has been
restored following an error, such as a power interruption. The remaining seconds are counted down on the display during the power-ON delay
time.
Table 5-5 Recovery time of the KP100G
Model
Country
Recovery Time (sec)
KP100G-OD-ES
Spain
180
KP100G-OD-IT
Italy
20
KP100G-OD-DE
Germany
30
Pac:291W
Vac:222.2/222.8/223.3V
Iac:0.43/0.42/0.41 A
Frequenc y:50.00Hz
Status:Normal
12/05/06 16:31
Pac:0W
Vac:0.0/0.0/0.0V
Iac:0.00/0.00/0.00 A
Frequenc y:00.00Hz
Status:Fault
E1-0:No Utility
12/05/06 16:13
6. The setting in the case of particular countries
The setting in Italy (KP100G-OD-IT)
Auto Test
The inverter is supplied with an auto-test function which enables the user to verify the correct operation of the protection interface.
In order to select this function press the “
/
” button until the message "AUTO TEST" appears on the display panel. Press and hold the “OK” button
for at least 5 second, to initiate the auto-test procedure.
The first check to be made is the upper voltage threshold. The display panel will show “V↑ 276V ≤ 0.1S”, which is the value set for the upper voltage
threshold and the maximum delay admitted before the protection intervenes. The display will show the variation of the upper voltage threshold and the
voltage value of the mains supply as measured by the micro-controller. If the value of the threshold and the mains supply voltage are equal the inverter
will switch to the “fault” status, by doing so the inverter will disconnect from the grid and the display panel will show for example a message similar to
“T OK 233V -78ms”. This means that the threshold voltage and the measured mains supply voltage have become equal at 233V and the switching time
is 78 milliseconds.
By pressing the “OK” button again the display panel will show the lower voltage threshold check. The display will show a message similar to “V↓
185V ≤ 0.2S”, which is the value set for the lower voltage threshold and the maximum delay admitted before the protection intervenes. By pressing the
button once again, the display will show the variation of the lower voltage threshold and the voltage value of the mains supply as measured by the
micro-controller. If the value of the threshold and the mains supply voltage are equal the inverter will switch to the “fault” status, by doing so the
inverter will disconnect from the grid and the display panel will show for example a message similar to “T OK 233V -53ms”. This means that the
threshold voltage and the measured mains supply voltage have become equal at 232V and the switching time is 53 milliseconds.
By pressing the “OK” button again the display panel will show the upper frequency threshold check. The display will show a message similar to “f↑
50.2Hz ≤ 0.06s”, which is the value set for the upper frequency threshold and the maximum delay admitted before the protection intervenes (in reality
the display would not show this value, as the 0.06s step (3 cycles) has only been shown as the protection is not sensitive to the frequency variations less
than 40ms (two cycles)). By pressing the button once again, the display will show the variation of the upper frequency threshold and the frequency
value of the mains supply as measured by the micro-controller. If the value of the threshold and the mains supply frequency are equal the inverter will
switch to the “fault” status, by doing so the inverter will disconnect from the grid and the display panel will show for example a message similar to “T
OK 49.95Hz -48ms”. This means that the threshold and the measured mains supply frequency have become equal at 49.95Hz and the switching time is
48 milliseconds.
By pressing the “OK” button again the display panel will show the lower frequency threshold check. The display will show a message similar to “f↓
49.7Hz ≤ 0.06s”, which is the value set for the lower frequency threshold and the maximum delay admitted before the protection intervenes (in reality
the display would not show this value, as the 0.06s step (3 cycles) has only been shown as the protection is not sensitive to the frequency variations less
than 40ms (two cycles)). By pressing the button once again, the display will show the variation of the lower frequency threshold and the frequency
value of the mains supply as measured by the micro-controller. If the value of the threshold and the mains supply frequency are equal the inverter will
switch to the “fault” status, by doing so the inverter will disconnect from the grid and the display panel will show for example a message similar to “T
OK 50Hz -60ms”. This means that the threshold and the measured mains supply frequency have become equal at 50Hz and the switching time is 60
milliseconds.
The “AUTO TEST” function is considered successful once all the previous 4 tests have been performed: in this case the message "TEST PASSED" will
appear on the display panel. By pressing the “OK” button, the inverter will switch to the normal operation mode (only if the mains supply is with the
specified tolerances). If one of the previous 4 tests fail, the display shows the message "AUTO TEST FAILED" and the inverter will permanently
switch to the “fault condition”. In this case contact the customer service center in order to return the inverter normal operation.
KP100G shows the status, measured values, graphs of generated power, etc. on LCD (Data Logger).
Using the LCD (Data Logger)
Operation
Keys
. “ ”: To lower layer (1st to 2nd) or moving cursor right
. “ ” : To higher layer (2nd to 1st) or moving cursor left
. “
” : To change back previous screen or moving cursor up
. “
” : To change to next screen or moving cursor down
. “OK” : To set or confirm
Backlight
The backlight of LCD will be lighted up whenever any key is pressed. To save the power, inverter should continue the lighting for 3 Minutes after the
last activity. But whenever a “failure error” occurs, the backlight in red continues switch on and off alternatively every 1 second.
Audible Alarm
The alarm beeps when
1. Inverter failure
2. Memory is less than 5%
3. Fan Lock
This alarm can be “off” by setting. The default value is “On”.
Insufficient memory warning
When the storage capacity reaches 95%, the inverter must notice the information to user by display and audible alarm.
In case the user continues ignoring the message and the memory is full, the earliest data will be overwritten by latest data.
Data Logger Display
Initial screen (Welcome)
If DC voltage of the PV-Panel is greater than 260VDC, KP100G power on. After power on of the KP100G, the LCD should show the brand and f/w
information. The screen lasts for 5 seconds and switch to text display.
Text display
In the display, there are 4 lines of “numerical parameters” and one “text status”. In the right-bottom line, it shows time and date information.
If the inverter shows “warning” or “error” message, the bottom line (Status) is automatically replaced by the message.
To change the setting, press “ ”. A cursor appears on item to be set. By using “
” and “
”, user can move the cursor to where he interested. Press
“OK” on the item to change the setting, use “
” and “
” to change the number, press “OK” again to confirm.
Operating Modes
The KP100G starts up automatically once DC-power from the PV-Panel is sufficient. There are 4 modes of operation.
1. States: Standby, Waiting, Normal
In this mode, the KP100G automatically detects the system status and selects the best mode of operation.
If DC voltage of the PV-Panel is greater than 350VDC, LCD shows “waiting”. During the wait state, the KP100G begins checking its own internal
status.
If the internal status is good after 30sec in the wait state, PV power is converted to AC fed into the grid and the status is entered “Normal”. During
normal mode, the green LCD is on.
Pac:0W
Vac:222.2/222.8/223.3V
Iac: 0.00/0.00/0.00 A
Frequenc y:50.00Hz
Status:Standby
12/05/06 16:31
Pac:291W
Vac:222.2/222.8/223.3V
Iac:0.43/0.42/0.41 A
Frequenc y:50.00Hz
Status:Normal
12/05/06 16:31
Pac:0W
Vac:222.2/222.8/223.3V
Iac: 0.00/0.00/0.00 A
Frequenc y:50.00Hz
Status:Waiting
12/05/06 16:31
KP100G-OD-ES
Ver 01.05
Pac:291W
Vac:222.2/222.8/223.3V
Iac:0.43/0.42/0.41 A
Frequenc y:50.00Hz
Status:Normal
12/05/06 16:31
2. Fault recovery (Temporary Fault)
The KP100G’s Data Logger continuously monitors the system status. When unexpected conditions such as grid problems or system fault which defined
in “error message table” occur and the inverter recovers itself within 48 hours, the LCD turns yellow color.
3. Fault (Permanent Fault)
The status of disconnection due to system fault and inverter failure defined in “error message table”. The inverter is disconnected from grid at that
moment and the error message is shown and the LCD turns red color. When inverter has problem, there will be “warning” or “fault” followed by
“Status”. And an additional message of warning or fault situation is showed and blinking below “Status” line.
4. Shutdown
If DC voltage decreases than 200VDC at the moment of reduced sunlight, the KP100G automatically shuts down. The display is not shown and the
operation keys are inactive.
Daily graph
By pressing “
” key in text display, the display is switched to daily display as above. The principles of design are:
Time-axis (x-axis): 12 hours maximum can be displayed. The first data of a day is plotted on the left most point. Until the first set point, the
time axis then shows the number. Every hour is divided into 10 points, each point is the average power during 6 minutes.
Power-axis (y-axis): Fixed value from 0 to 12kW. Every segmentation indicates 1kW.
Date information: On the upper right corner, the date of present display is shown.
Date change: By pressing “ “ and “ ”, user can switch the date he interested. The corresponding date has to be changed in the same manner
More view: If the data recorded in more than 12 hours, user can press “OK” to set. After doing that, he can use “ “ and “ ” to shift the time he
interested. But the maximum display on the screen is still 12 hours.
Pac:0W
Vac:0.0/0.0/0.0V
Iac:0.00/0.00/0.00 A
Frequenc y:00.00Hz
Status:FAULT
E1-0:No Utility
12/05/06 16:13
Pac:291W
Vac:222.2/222.8/223.3V
Iac:0.43/0.42/0.41 A
Frequenc y:50.00Hz
Status:Normal
12/05/06 16:31
E1-0:No Utility
Press OK to Clear
By pressing up “
” key from previous at any time, the weekly display shows. The principles are:
Time-axis: 7 days from Sunday of a week. The left most point is the data of Sunday.
Accumulated kWh (Y-axis): The amount is kWh of that day. From 0 to 100kWh
Week change: By pressing “ “ and “ ”, user can switch the week he interested. The corresponding dates on the upper-right corner has to be
changed as well.
Error history
In this screen, inverter shows the latest 2 errors for the past as below. By pressing “ “ and “ ”, error history scrolls and user can see previous errors.
System display
SN: the serial number of the inverter
Version: the firmware version of the inverter
Memory: the used percentage of total capacity
Date: The date setting in the RTC (Real Time Clock) Day: The day of the week
Time: The time setting in the RTC Time Zones: Setting in GMT
Audible Alarm: “ON” or “OFF”, the status of the setting
Language: The current setting of display language
To change the setting, press “ ”. A cursor appears on item to be set. By using “
” and “
”, user can move the cursor to where he interested. Press
“OK” on the item to change the setting, use “
” and “
” to change the number, press “OK” again to confirm.
S ystem Display
SN:SV10000-01
Version:00.21-00.04
Memor y:1.7%
Date:12/13/06 Wed
Time:16:15:05 GMT+08
AUDIO AL ARM:ON
LANGUAGE:E NG
Error Histor y
E565:E1- A
@ 05/10/07 14:22
Value=0.0.0
E566:E1-0
@ 05/10/07 14:24
Value = N/A
Protocol: “TYPE1” or “TYPE2”, to select protocol of communication
To communicate by OMRON protocol, select TYPE1.
Node No.: Node number setting of the inverter. Only valid whenTYPE1 protocol is selected
Baud rate: Baud rate setting of communication. Only valid when TYPE1 protocol is selected
Baud rate is 9600bps or 19200bps. Default value is 19200bps.
Data Logger Function Guideline
Function Tree
Initial Screen
1st Layer
2nd Layer
Communication Settings
Protocol:TYPE1
Node No:1
Baud rate:19200bps
Text display
Daily graph
Weekly graph
Error History
System Display
Communication
Setting
Channel selection
Channel selection
Channel selection
Channel selection
Staus:Normal
Date Time
1. Select channel by
2. Press “OK” to change
3. Select parameter by using
4. Press “OK” to confirm and back
1. The display is shown from first data of a day
2. Up to 12 hours can be displayed
3. Select date by using
1. The display is shown from first data of a week, Sunday
2. 7days on one display
3. Select week by using
1. The latest 2 errors for the past are shown
2. Older errors than those errors are displayed
by using
System Display
SN:
Version:
Memory:
Date Day
Time Time Zones
Audible Alarm
Language
1. Use
to select item
2. Press “OK” to set
3. Use
to change number
4. Use
to move cursor
5. Press “OK” again to confirm
Communication Setting
Protocol setting
Node NO. setting
Baudrate selection
1. Use
to select item
2. Press “OK” to set
3. Use
to change number
4. Use
to move cursor
5. Press “OK” again to confirm
Welcome
After 5
seconds
8. System Monitoring
Data Communications
The connection type is 1:1 or 1:N. In a 1:N installation, up to 32 units, including the host computer can be connected.
The maximum total cable length is 500 m.
Use a shielded twisted pair cable 0.3 mm2.
Use a resistance of 100 to 125 Ω (1/2 W) in the terminators. Install terminators at both ends of the transmission path, including the host computer.
To connect to an RS-232C port on a computer, use a 232C-485 converter.
Example converter: K3SC (RS-232C-RS-485 Interface Converter)
RS-485 Communications
To communicate with multiple KP100G Units, you can connect them to a personal computer via RS-485 ports. The maximum cable length is 500 m.
RS-485 allows communication with up to 31 Units.
RS-485 communications require a cable of the appropriate length and a personal computer installed with monitoring software.
Baud rate is 9,600bps or 19,200bps. Default value is 19,200bps.
Fig, 8-1 Schematic layout of RS-485 data transmission with several KP100G Units
RS-232C/ RS-485
RS-485
RS-232C
RS-485
RS-232C/ RS-485
RS-485
RS-232C
RS-485
RS-485
NS8
CJ1M
NS8
up to 31 units
up to 10 units
up to 10 units
up to 248 units
Fig, 8-2Fig, 8-1Fig, 8-2 shows the wiring diagram.
Use an RS-232C/RS-485 Interface Converter for connection with the personal computer.
Connect a terminator plug to the communications cable for the last KP100G Unit in the series. 0.3 mm2 shielded twisted pair cable is recommended for
RS-485 connection.
Fig, 8-2 Wiring KP100G Units to a personal computer (RS-485)
100 to 125 Ω (1/2 W)
Personal
Computer
RS-485 Terminal
RS-232C/RS-485
Converter (K3SC)
DB (+) DA (-)
RS-485 Terminal
RS-485 Terminal
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
T+
T-
R+
R-
T+
T-
R+
R-
T+
T-
R+
R-
T+
T-
R+
R-
T+
T-
R+
R-
T+
T-
R+
R-
KP100G can be easily communicated with the Data Logger.
Table 8-1 Specification of Data Logger
Displayed information
each input power, output power, operation mode and warning message
Data capacity
3 years
Storage media
Internal memory (SD card)
User can not exchange storage media.
Data download
Via USB (Type A to mini-B USB Cable)
Data download
User can download and manage the stored data by another computer. For KP100G, user can take out the data logger and access its internal data via
USB without providing external power. The power in this case is provided by USB port of computer.
Use can not download via communication such as RS-232C and RS-485.
For more information, please contact the store from which you purchased the product.
RS-232C Communications
The simplest and least expensive way to communicate between a single KP100G and a personal computer is to connect directly via RS-232C ports. The
maximum cable length between the personal computer and the KP100G is 15 m.
Fig, 8-3 Example of RS-232C communications with a single KP100G
RS-232C communications require the appropriate cable and a personal computer installed with monitoring software.
The RS-232C connection is shown in P.27.
Note: If the RS-485 card is inserted, RS-232C is not available. To use the RS-232C, remove the RS-485 card.
RS-232C
LCD(Data Logger) Messages
Operating
conditions
In English
In German
In Spanish
In Italian
Description
Normal Working Status
Shown in “Status” row on the display
Power off
PV inverter is totally shutdown,
BUS voltage < 200V
Standby
STATUS:STANDBY
Status:Bereitschaft
ESTADO:EN ESPERA
IN ATTESA
IPV <200V & 600V< BUS
voltage
Initialization &
waiting
STATUS:Waiting
Status:Warten
ESTADO:PREPARADO
PRONTO
Input voltage range 260~350V
during start-up.
Check grid
STATUS:CHECKING
xxxs
Status:Netz-Prüf xxxs
ESTADO:CHEQUEO
xxxs
VERIFICA RETE xxxs
When PV voltage> 350V,
inverter is checking feeding
conditions
Feeding grid,
MPPT
STAUS:Normal
Status:Normalbetriebe
ESTADO:NORMAL
NORMALE
Inverter is feeding power. After
10 seconds of this display, LED
will show wattage.
Waiting for
reconnect to grid
STATUS:RECONNECT
xxxs
Status:Kontakt xxxs
ESTADO:RECONEX
xxxs
RICONNESSIONE xxxs The time for reconnect to grid
FAULT
STATUS:FAULT
Status:Fehler
ESTADO:ANOMALIA
SISTEMA IN ERRORE
See “System Fault”,
“Inverter Fault” to know
the fault detail
Monitoring Parameters
Information on display
Instantaneous Input
power
Pdc:xxxx/xxxx/xxxxW
Pdc:xxxx/xxxx/xxxxW
Pdc:xxxx/xxxx/xxxxW
Pcc:xxxx/xxxx/xxxxW
The individual DC input power
Instantaneous
Output power
Pac:xxxxxW
Pac:xxxxxW
Pac:xxxxxW
Pca:xxxxxW
The real time output power in
xxxx W
Accumulated
energy information Etot:xxxxxxxxx.xkWh
E-tot:xxxxxxxxx.xkWh
Etot:xxxxxxxxx.xkWh
Etot:xxxxxxxxx.xkWh
Total energy to has been fed to
grid since inverter was installed
3-phase Grid
voltage
Vac:xxx.x/xxx.x/xxx.xV Uac:xxx.x/xxx.x/xxx.xV Vac:xxx.x/xxx.x/xxx.xV
Vca:xxx.x/xxx.x/xxx.xV Grid voltage in xxx.x VAC for
3 phases
Grid frequency
Frequency:xx.xHz
Frequenz:xx.x Hz
Frecuencia:xx.x Hz
Frequenza:xx.x Hz
Grid frequency in xx.x Hz
Feeding current
Iac:xx.x/xx.x/xx.xA
Iac:xx.x/xx.x/xx.xA
Iac:xx.x/xx.x/xx.xA
Ica:xx.x/xx.x/xx.xA
Feeding current amount in xx.x
A
PV array voltage
Vdc:xxx/xxx/xxxV
Udc:xxx/xxx/xxxV
Vdc:xxx/xxx/xxxV
Vcc:xxx/xxx/xxxV
Input voltage of PV array, xxx
VDC
PV array current
Idc:xx.x/xx.x/xx.xA
Idc:xx.x/xx.x/xx.xA
Idc:xx.x/xx.x/xx.xA
Icc:xx.x/xx.x/xx.xA
Input DC current of tracker
Daily Energy
Etoday:xxx.xkWh
E-Heute:xxx.xkWh
Edia:xxx.xkWh
Egiorno:xxx.xkWh
The accumulated kWh of that
day
Working Hour
H-total:xxxxxxhr
H-total:xxxxxxhr
Htot:xxxxxx
Ore tot:xxxxxx
Total working hours of inverter
Internal
Temperature
TEMPERATURE:xx.xºC Temperatur:xx.xºC
Temperatura:xx.xºC
Temperatura:xx.x°C
Temperature is indicated in
Celsius
System Fault and Inverter Fault
Shown in “Status” row on the text display and Error display
No utility
E1-0:No Utility
E1-0:Kein Netz
E1-0:SIN RED
E1-0:Assenza rete
Utility is not available
Grid failure
(Over voltage)
E1-1:Grid OV
E1-1:Netzfehler OV
E1-1:ERR Red OV
E1-1:Err Rete OV
Grid measured data is beyond
the specification (Over voltage)
Grid failure
(Under voltage)
E1-2:Grid UV
E1-2: Netzfehler UV
E1-2: ERR Red UV
E1-2:Err Rete UV
Grid measured data is beyond
the specification (Under
voltage)
Grid failure
(Over frequency)
E1-3:Grid OF
E1-3: Netzfehler OF
E1-3: ERR Red OF
E1-3:Err Rete OF
Grid measured data is beyond
the specification (Over
frequency)
Grid failure
(Under frequency) E1-4:Grid UF
E1-4: Netzfehler UF
E1-4: ERR Red UF
E1-4:Err Rete UF
Grid measured data is beyond
the specification (Under
frequency)
Grid failure
(Islanding active)
E1-6:Islanding active
E1-6:Inselbetriebs
E1-6:Modo isla detect
E1-6:Isola attiva
Utility is not available
(Islanding operation detected)
Grid failure
Over voltage
instantly
E1-7: OV instantly
E1-7:OV sofort
E1-7:OV inmediata
E1-7:OV immediata
Grid measured data is beyond
the specification (Over voltage
instantly)
Input voltage too
high
E2-1:PV over voltage
E2-1:DC-Überspg
E2-1:SOBRETENSION
DC
E2-1:Sovratensione cc
Input voltage higher than the
permissible 800V
GFCI active
E2-3:Ground I Fault
E2-3:Fehlerstrom
E2-3:ERR DERIVACION E2-3:Err Dispersione
Leakage current on ground
conductor is too high
Isolation failure
E2-4:Isolation fault
E2-4:Isolationsfehle
E2-4:ERR
AISLAMIENTO
E2-4:Err Isolameto
Earth fault of the PV-panels or
failure of surge voltage
protection
AutoTest failed
E5-9:AUTO TEST
FAILED
E5-9:AUTO TEST fehler E5-9:ERR AUTO TEST
E5-9:Err Autotest
Auto test failed
Temperature too
high
E3-4:Over temperature
E3-4:Übertemperatur
E3-4:
SOBRETEMPERATURA E3-4:Sovratemperatura
The internal temperature is
higher than normal value
Memory card full
A2-7:Memory Full
A2-7:Memory Full
A2-7:MEMORIA LLENA A2-7:Memoria piena
There is not enough space to
store data
System Information
Serial Number
S/N:xxxxxxxxxxxxxxxx SN:xxxxxxxxxxxxxxxx
S/N:xxxxxxxxxxxxxxxx
MAT:xxxxxxxxxxxxxxx
x
10 characters unique serial
number
Firmware version
Version:xx.xx-xx.xx
Version:xx.xx-xx.xx
Versión:xx.xx-xx.xx
Versione:xx.xx-xx.xx
The Master and Slave CPU
F/W version information
SD card memory
MEMORY:xx.x%
Speicher:xx.x%
MEMORIA:xx.x%
MEMORIA:xx.x%
Memory utilization on SD card
Date display
DATE:DD/MM/YY XXX
XXX:SUN
MON
TUE
WED
THU
FRI
SAT
Datum:DD/MM/YY XXX
XXX:Son.
Mon.
Die.
Mit.
Don.
Frei.
Sam.
FECHA:DD/MM/YY XXX
XXX:DOM
LUN
MAR
MIE
JUE
VIE
SAB
DATA:DD/MM/YY XXX
XXX:DOM
LUN
MAR
MER
GIO
VEN
SAB
Date display
DD: day
MM: Month
YY: Year
Time display
TIME:HH/MM/SS
GMT+xx
Zeit:HH/MM/SS
GMT+xx
HORA:HH/MM/SS
GMT+xx
ORA:HH/MM/SS
GMT+xx
Time display
Set up audible alarm
Setting Language
LANGUAGE:XXX
XXX:ENG
ESP
GER
ITA
Sprache: XXX
XXX:Englisch
ESP
Deutsch
ITA
IDIOMA:XXX
XXX:ENG
ESP
GER
ITA
Lingua:XXX
XXX:ENG
ESP
DEU
ITA
Set up of the display language
Warning Message
Shown in warning row
Memory is to be
full
MEMORY LEFT xx.x% memory left xx.x%
MEMORIA LIBRE
xx.x%
Memoria Libera xx.x%
When the memory space of
card is less than 5%, this
warning should be displayed in
the status.
Fan Lock
A2-5:Fan Lock
A2-5:FanLock
A2-5:ERR
VENTILADOR
A2-5:Err Ventola
The fan for heat dissipation is
stopped abnormally
9. Technical Data
DC Side:
Max. input open-circuit voltage:
VPVO
800 VDC
DC input voltage range
200 to 800 V
MPPT voltage range
VPV1
300 to 800 V
Nominal input voltage
640VDC
Max. input current
Imax
39ADC
Max input current per one pair of DC connector
13ADC
Max. input power
5,500W / Tracker
All pole disconnection on DC side:
DC connectors (3 pairs)
Personnel protection:
Earth fault monitoring
AC Side:
Output values (grid)
Nominal power:
PAcnom
10,000 W
Peak power:
Pacmax
11,000 W
Nominal Output Current
IAC_nom
14.5A
THD of output current
3% or less
Output voltage range:
400Vac -15%+10% (KP100G-OD-ES)
400Vac -20%+15% (KP100G-OD-DE, KP100G-OD-IT)
Output frequency range:
47.5 to 50.2Hz (KP100G-OD-DE)
49.7 to 50.3Hz (KP100G-OD-IT)
49 to 51Hz (KP100G-OD-ES)
All pole disconnection, grid side:
Mains monitoring with two independent
allocated switching devices
Over voltage Category
III
Self-consumption during nighttime
3.5W or less
External interfaces
Data transmission:
RS-232C/RS-485/ type A to mini-B USB (electrically-isolated)
Certifications
EMC
EN 61000-6-2, EN 61000-6-3 ,EN 61000-3-2
Grid monitoring:
VDE0126-1-1 (KP100G-OD-DE)
Low voltage regulation:
EN50178
Spanish regulation
RD1663/2000 (KP100G-OD-ES)
Italian regulation
ENEL DK5940 (KP100G-OD-IT)
Enclosure
Protection (acc. to DIN EN 60529)
Housing: IP65
Weight and Dimensions
Dimensions (w x h x d):
452 × 583 × 152 mm
Weight:
Approx. 34 kg
Ambient Conditions for Operation
Tolerable ambient temperature:
-20 to +55°C
Tolerable relative humidity:
0 to 95%, non-condensing,
Efficiency
Max efficiency:
96.5%
Euro efficiency:
95%
Ppv(W) = 13 x Vpv
Example: VPV is 400VDC, the maximum power could
take by inverter in one string is 5200W.
Fig, 9-1 Load Graph of KP100G
Additionally tighten the tightening cap
The cable may thin slightly due to usage conditions.
This requires that you additionally tighten the tightening cap regularly.
Fig, 10-1 Additional tightening of the tightening cap
Others
Please keep the original carton box and use it for transportation of the Omron KP100G PV Inverter when it has to be transported as such for a repair
service.
11. Troubleshooting
When You Suspect a Problem
Operation does not start immediately even though the connectors are correctly connected.
•
The power generation of the solar modules is insufficient. Operation will begin when the sunlight intensity increases.
The LCD does not show the status “Normal”.
•
The connectors are not correctly connected.
The power generation level is low even on a sunny day.
•
The Screen filter may be clogged, or the service life of the fan may have been reached, in which case the fan needs to be replaced.
•
The solar modules may be obstructed or shaded by something.
•
The grid voltage may have risen. Contact the store from which you purchased the product.
12. Meanings of Error Messages and Their Remedies
Troubleshooting
Your PV-Inverter requires very little maintenance. When unexpected situation occurs, please refer to the following table should further assistance be
required before calling your local dealer. The following table lists common fault messages that display when the fault LED is lit, and their solutions.
Fault Message
Fault definition
Possible Causes
Proposed Actions for
End-user
Proposed Actions for Professionals
E2-3:Ground I Fault
The fault current
detected by the inverter
is higher than threshold.
1. Obstacle, humidity or
water exits between AC
LINE and/or NEUTRAL
to earth ground.
2. Obstacle, humidity or
water exits between AC
LINE and/or NEUTRAL
to earth ground in the
junction box.
3. The Insulation of AC
wires is broken that could
be bit by rat or any
animals.
4. Inverter is abnormal.
1. Disconnect AC connection of
inverter by opening AC switch.
2. Check the AC junction box and
wiring of system. Clear obstacle
ONLY IN SAFE CONDITIONS
3. Reconnect AC connection, check
the status of inverter.
4. If the problem persists, contact the
store from which you purchased
the product or your installer.
1. Disconnect AC side of inverter by
opening AC switch.
2. Disconnect the DC side from the
inverter.
3. Check both the AC and DC wiring
and insulation.
4. Reconnect AC connection, check
the status of inverter
5. If the problem persists, please
replace the inverter.
In Text display
E1-1:Grid OV
E1-2:Grid UV
E1-6:Islanding
active
E1-7:OV instantly
In Error history
E1-A
In Text display
E1-3:Grid OF
E1-4:Grid UF
In Error history
E1-B
E1-1: OV (AC over
voltage) error due to
rise in voltage from
the utility.
E1-2: UV (AC under
voltage) error due to
drop in voltage from
the utility.
E1-3: OF (over-
frequency) error due
to rise in frequency
from the utility.
E1-4: UF (under-
frequency) error due
to drop in frequency
from the utility.
E1-6: Islanding
operation detected
(active system) due to
error in the power
from the utility.
E1-7: Voltage from the
utility has exceeded
383 V.
1. The detected AC voltage
is beyond/under the setting
of inverter.
2. The detected AC
frequency is beyond/under
the setting of inverter.
3. AC connection is not
correct.
4. Grid condition is weak or
unstable.
5. Other high-power
consumption device is
affecting the grid system.
6. The setting of inverter is
deviated from its default
values.
7. Inverter is abnormal.
1. If this problem occurs seldom
(such as 1 time a day), no action is
necessary. Operation will restart
automatically when the voltage
from the utility returns to normal.
2. If the problem occurs frequently,
do the actions below.
3. Find the device with high power
consumption near your AC system.
4. Use inverter software to check the
setting of inverter. The setting
should be in the range listed in
specification.
5. If the settings are not correct, call
your service for changing.
6. Use inverter software or
monitoring device to collect data.
Send the data to professionals for
further investigation.
7. Consult your utility power
supplier, understand the grid
conditions.
8. Ask help of your installer.
1. Check the system connection
including polarities and security
first.
2. Find the devices with high power
consumption near the AC system.
3. Consult the utility power supplier,
understand the grid conditions.
4. Use inverter software to monitor
the frequency and voltage.
5. If the measured data beyond the
setting, under the permission of
utility supplier, use the software to
change parameters.
6. If the situation is not improved
after changing parameters, please
replace the inverter.
E1-0:No Utility
Inverter is not able to
detect AC voltage.
1. Grid is not available.
2. AC connection is incorrect
3. AC switch between
inverter and utility is not
ON.
4. AC fuse and/or breaker is
open.
5. Inverter is abnormal.
1. Make sure the breaker and switch
on AC side are close. Operation
will restart automatically when the
voltage from the utility returns to
normal.
2. Check the AC wiring.
3. If the problem persists, contact the
store from which you purchased
the product or your installer.
1. Make sure the breaker and switch
on AC side are close.
2. Check the AC wiring.
3. If the problem persists, please
replace the inverter.
E2-1:PV over voltage
The detected PV
voltage is higher than
specification.
1. The PV array voltage is
too high.
2. Inverter is abnormal.
1. Open DC connection of inverter
and reconnect. Operation will
restart automatically when the
solar module output voltage
lowers.
2. If the fault continues, contact the
store from which you purchased
the product or your installer.
1. Check the open PV voltage, and
see if it is more than or too close to
specification.
2. If PV voltage is much less than
specification and the problem still
occurs, please replace the inverter.
Proposed Actions for
End-user
Proposed Actions for Professionals
E2-4 : Isolation fault
Insulation resistance
has dropped in the solar
module equipment.
1. The PV array installation
or the array themselves
might be faulty.
1. Make sure the breaker and switch
on AC side are close. Operation
will restart automatically when the
voltage from the utility returns to
normal.
2. Check the AC wiring
3. If the problem persists, contact the
store from which you purchased
the product or your installer.
1. Make sure the breaker and switch
on AC side are close.
2. Check the AC wiring
3. If the problem persists, please
replace the inverter.
E3-4:Over
Temperature
KP100G internal
temperature is high.
1. Ambient temperature is
too high.
2. Heat dissipation problem
3. Inverter is abnormal.
1. Make sure the ambient temperature
of installation is less than 55°C.
Operation will restart
automatically when the
temperature returns to normal.
2. Check the space near the heat sink.
3. Remove any obstacle that block.
the heat dissipation near heat sink
4. If the problem persists, contact the
store from which you purchased
the product or your installer.
1. Make sure the ambient temperature
of installation is less than 55°C.
2. Check the space near the heat sink.
3. Remove any obstacle that block
the heat dissipation near heat sink.
4. If the problem persists, please
replace the inverter.
A2-5: Fan Lock
The fan rpm has
dropped.
1. Something is blocking the
ventilation holes.
2. The end of life time of the
fan.
3. The fan is abnormal.
1. If something is blocking the
ventilation holes in the side panel,
remove it.
2. If nothing is blocking the
ventilation holes, the fan may have
reached the end of its service life.
Contact the store from which you
purchased the product or your
installer.
1. If something is blocking the
ventilation holes in the side panel,
remove it.
2. If nothing is blocking the
ventilation holes, the fan may have
reached the end of its service life.
Call your local dealer.
Other Error messages
The KP100G detects an
abnormality.
1. Contact the store from which you
purchased the product.
The main ground-fault
breaker trips frequently.
Ground faults are being
caused by electrical
appliances, the
KP100G, or the solar
modules.
1. Check to make sure that the ground
faults are not being caused by
electrical appliances.
2. If no abnormalities are found,
contact the store from which you
purchased the product to measure
the insulation resistance of the
KP100G and the solar modules.
Also describe the circumstances
under which the problem happens
(for example, the problem occurs
on the morning after a rainy day,
etc.).
13. Other Information
Applicable Conditions
a) When using OMRON Products in combination with other products, it is user’s responsibility to confirm the suitability of the OMRON Products
for the system, devices, and equipment that are being used. OMRON accepts no responsibility for the suitability of OMRON Products used in
combination with other products.
b) When using OMRON Products in any of the following applications, consult an OMRON representative and check specifications to allow
sufficient leeway in ratings and performance, and to implement suitable safety measures, such as safety circuits, to minimize danger in the event of
an accident.
i) Outdoor applications, applications with potential for chemical contamination or electrical interference, or application under conditions or
environments not described in catalogs.
ii) Nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, or
equipment regulated by government or Industrial standards.
iii) Other systems, machines, and equipment that may have a serious influence on human life and property.
iv) Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems, and systems that operate 24 hours a day.
v) Other applications requiring a high level of safety, corresponding to points i) to iv), above.
c) When OMRON Products are used in an application that could pose significant risk to human life or property, the overall system must be
designed so that the required safety can be ensured by providing notice of the danger and incorporating redundancy into the design. Make sure
that OMRON Products are appropriately wired and mounted to serve their intended purpose in the overall system.
d) Application examples provided in manual are for reference only. Confirm functionality and safety before actually using the devices and equipment.
e) To prevent unexpected problems from arising due to the OMRON Product being used incorrectly by the customer or any other party, make sure
that you understand and carefully observe all of the relevant prohibitions and precautions.
Changes to Specifications
Specifications and accessories to the products in catalogs may be changed as needed to improve the products or for any other reason. Check with your
OMRON representative for the actual specifications for OMRON Products at the time of purchase.
Certificates for the KP100G
・CE mark, self-declaration of conformity
・VDE0126-1-1 test report by TUV
・RD1663/2000 self-declaration
・DK5940
When requesting service…
In situations such as the following, stop the KP100G operation and contact the store from which you purchased the product.
• The KP100G is operating, but nothing is displayed.
• When the malfunction massage show
• When the breaker trips frequently
• When a foreign object or liquid accidentally enters the product
When you contact the store, provide them with the following information:
• Type
• Serial number
• Purchase date
• Details of the problem (A description of the malfunction)
• Your address, name and phone number
16. Contact address
OMRON Europe B.V.
Wegalaan 67-69, 2132 JD Hoofddorp,
The Netherlands
Phone: +31 (0)23 56 81 300
Fax: +31 (0)23 56 81 388
Web site: www.eu.omron.com
OMRON Corporation
Industrial Devices and Components Division H.Q.
Power Electronics Department
Shiokoji Horikawa, Shimogyo-ku, kyoto, 600-8530 Japan