KRUEGER LMHS Installation, Operation & Maintenance Manual

File Specifications

Brand: KRUEGER
Category: Industrial Equipment
Model: LMHS (Installation, Operation & Maintenance Manual), prJ5GmkTS/95M
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 24 pages

Download PDF

Download KRUEGER LMHS Manual (24 pages)

Read Online:

Read the KRUEGER LMHS Installation, Operation & Maintenance Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

1401 N. Plano Rd.

Richardson, TX 75081 tel: 972.680.9136 www.krueger-hvac.com [email protected] Single Duct & Retrofit Terminal Unit IOM | Rev. 09/22/2020 ©Krueger 2020. All Rights Reserved. YOUR RESOURCE FOR AIR DISTRIBUTION AND EQUIPMENT SOLUTIONS Let us know how we can assist you in your next building application. For more information, contact your local Krueger representative or visit us on the web at www.krueger-hvac.com. CRITICAL ROOM SOLUTIONS CHILLED BEAMS DISPLACEMENT VENTILATION UNDERFLOOR Underfloor Diffusers Underfloor Terminal Units TERMINAL UNITS Single Duct Fan Power ...

Single-Duct and Retrofit Terminal Units IOM

TABLE 6.C: RVE BASIC PRESSURE AND AIRFLOW DATA INLET SIZE (AREA SQFT) MAX AIRFLOW (CFM) MIN AIRFLOW (CFM) FLOW RATE (CFM) MIN ΔPs (IN WG) 4 (0.09) 230 40 40 103 167 230 0.007 0.048 0.126 0.239 5 (0.14) 360 62 62 161 261 360 0.008 0.052 0.137 0.261 6 (0.20) 515 90 90 233 377 520 0.007 0.05 0.131 0.249 7 (0.27) 700 121 120 330 525 700 0.007 0.056 0.142 0.252 8 (0.35) 920 160 160 440 675 920 0.008 0.059 0.138 0.256 9 (0.44) 1160 201 200 550 875 1160 0.008 0.058 0.146 0.257 10 (0.55) 1430 248 250 675 1075 1430 0.008 0.056 0.142 0.252 12 (0.78) 2060 3 ...

Single-Duct and Retrofit Terminal Units IOM

TABLE 6.B: LMHS-LC BASIC PRESSURE AND AIRFLOW DATA INLET SIZE (AREA SQFT) MAX AIRFLOW (CFM) MIN AIRFLOW (CFM) MIN INLET STATIC PRESSURE (UNIT & HEAT PRESSURE DROP) COOLING ONLY OR WITH HOT WATER CFM BASIC UNIT BASIC WITH 1R - COIL BASIC WITH 2R - COIL BASIC WITH 3R - COIL BASIC WITH 4R - COIL Δ Ps Δ Ps Δ Ps Δ Ps Δ Ps 4 (0.09) 230 40 55 110 150 225 0.01 0.01 0.1 0.23 0.01 0.06 0.11 0.25 0.02 0.07 0.12 0.28 0.02 0.07 0.14 0.3 0.02 0.08 0.15 0.32 5 (0.14) 358 62 85 140 250 355 0.01 0.03 0.1 0.2 0.02 0.04 0.13 0.25 0.02 0.05 0.16 0.3 0.02 0.06 ...

Single-Duct and Retrofit Terminal Units IOM

TABLE 6.D: SVE BASIC PRESSURE AND AIRFLOW DATA INLET SIZE MAX AIRFLOW (CFM) MIN AIRFLOW (CFM) FLOW RATE (CFM) MIN ΔPs (IN WG) A 456 79 75 155 235 315 0.057 0.242 0.556 1 B 656 114 114 225 350 473 0.058 0.226 0.548 1 C 875 152 152 350 575 786 0.037 0.198 0.535 1 D 1458 253 253 475 675 902 0.079 0.278 0.561 1.001 E 2042 354 354 675 1000 1328 0.071 0.258 0.567 1 F 1969 351 341 650 950 1270 0.072 0.262 0.56 1.001 G 2188 379 379 725 1075 1435 0.07 0.255 0.561 1 H 3281 568 568 1175 1775 2414 0.055 0.237 0.541 1 TABLE 6.D: SVE BASIC PRESSURE AND AIRFLOW ...

Single-Duct and Retrofit Terminal Units IOM

TABLE 6.D: SVE BASIC PRESSURE AND AIRFLOW DATA INLET SIZE MAX AIRFLOW (CFM) MIN AIRFLOW (CFM) FLOW RATE (CFM) MIN ΔPs (IN WG) A 456 79 75 155 235 315 0.057 0.242 0.556 1 B 656 114 114 225 350 473 0.058 0.226 0.548 1 C 875 152 152 350 575 786 0.037 0.198 0.535 1 D 1458 253 253 475 675 902 0.079 0.278 0.561 1.001 E 2042 354 354 675 1000 1328 0.071 0.258 0.567 1 F 1969 351 341 650 950 1270 0.072 0.262 0.56 1.001 G 2188 379 379 725 1075 1435 0.07 0.255 0.561 1 H 3281 568 568 1175 1775 2414 0.055 0.237 0.541 1 TABLE 6.D: SVE BASIC PRESSURE AND AIRFLOW ...

Single-Duct and Retrofit Terminal Units IOM

LMHS WATER COILS - 2 ROW PART NUMBER Unit Size 4-6 00-20020-02 Unit Size 7-8 00-20021-02 Unit Size 9-10 00-20023-02 Unit Size 12 00-20024-02 Unit Size 14 00-20025-02 Unit Size 16 00-20030-02 Unit Size 20 00-20359-02 Unit Size 22 00-20029-02 NOTE: 1 & 2 Row Coils can be used for both left and right-hand orientation. LMHS WATER COILS - 3 ROW PART NUMBER Unit Size 4-6 00-20042-02 (RH) 00-20065-02 (LH) Unit Size 7-8 00-20031-02 (RH) 00-20066-02 (LH) Unit Size 9-10 00-20032-02 (RH) 00-20067-02 (LH) Unit Size 12 00-20033-02 (RH) 00-20068-02 (LH) Unit S ...

Single-Duct and Retrofit Terminal Units IOM

TABLE 5.A: LMHS UNIT WEIGHTS LMHS UNIT WEIGHTS (lbs.) HOT WATER COIL (DRY, lbs.) SIZE BARE BOX WITH PNEUMATIC WITH DDC OR ANALOG WITH ATTENUATOR 1 ROW 2 ROW 4,5,6 14 +4 +9 +10 +5 +6 7,8 16 +4 +9 +12 +5 +7 9,10 21 +4 +9 +16 +7 +9 12 26 +4 +9 +21 +9 +12 14 34 +4 +9 +24 +10 +15 16 38 +4 +9 +27 +12 +17 22 65 +4 +9 +30 +17 +25 TABLE 5.B: LMHS-LC UNIT WEIGHTS LMHS UNIT WEIGHTS (lbs.) HOT WATER COIL (DRY, lbs.) HOT WATER COIL (WITH WATER, lbs.) SIZE BARE BOX W/PNEUMATIC W/ DDC OR ANALOG W/ ATTENUATOR 1 ROW 2 ROW 1 ROW 2 ROW 4,5,6 16 +4 +9 +12 +5 +7 +5.8 ...

Single-Duct and Retrofit Terminal Units IOM

PNEUMATIC CONTROLS Volume controllers for LMHS units are shown below. Identification for each controller is shown in the following table. PNEUMATIC VOLUME CONTROLLERS KMC - CSC 2003 (Normally Open) KMC - CSC 2004 (Normally Closed) *LO and HI are reversed* KMC - CSC 3011 (Multi Function Controller) Figure 7: Pneumatic Volume Controllers TABLE 2: PNEUMATIC CONTROL SEQUENCE CONTROLLERS CONTROL SEQUENCE FUNCTION ARRANGEMENT KMC PART NUMBER 1102 DA-NO CSC-2003 1103 RA-NC CSC-2004 1104 DA-NO CSC-3011 1105 DA-NC CSC-3011 1106 RA-NO CSC-3011 1107 RA-NC C ...

KRUEGER LMHS user guide recommended for: MULTI-TREND, ARIES, Generation 3 PWM, TOBY-L2 series, xFUME VAC ADVANCED.

⚠️ Download Safety

The Industrial Equipment Installation, operation & maintenance manual (24 pages) is completely safe to download (last scan date: 27/05/2026).

Related PDF Instructions for KRUEGER LMHS:

Industrial Equipment Equipment: Frequently Requested

Have some Questions about KRUEGER LMHS Device?

Get valuable and actionable advices from other KRUEGER LMHS device users. Describe your problem or question, regarding the using of LMHS, in as much detail as possible, and other users will be able to answer you.