Pagina 1 van 5

http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini MCO Home MCO Home Glass Touch Switch GEN5 (2 Buttons) SKU: MCOETPS412 Quickstart This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. A This device is a Z-Wave Actuator. To include or exclude the device you only need to press and hold any key for 8 seconds. Important safety information Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importe distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use t equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources. Product Description The TPS412 by MCO Home is a wall switch with 2 integrated switch relays. The relays can be controlled both with the touch switches, which are integrated in the glass surface, and via Z-Wave commands. The relays can switch two loads with up to 1,100 watts each. Beside local switching the device can be used to control two groups of directly associated devices. A blue LED on every button indicates the switching status. The wall switch can be easily connected to an electrical load without installing a flush mounted module separately. The relays are located inside a module which is directly connected to the glass touch button. With that MCO Home wall switch you can replace any switch insert or toggle switch. The wall switch can be mounted on any flush box. With the stylish glass wall switches by MCO Home you can easily integrate your already installed lights into your home automation network. Without installing any news cable, you can switch your lighting as usual via wall switch – but thanks to Z-Wave technology also via remote control, smartphone or sensor- controlled automation. Installation Important: Please make sure you have cut off power supply before you start to install the device. Connect Hot Line to "L" Connect Neutral Line to "N" Connect Load wire to "L1"

Pagina 2 van 5

http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini Connect Load wire to "L2" 1. Remove the steel frame from the device, and secure it onto the junctions box with tow screws. 2. Insert all wires into the right terminals and tighten screws. 3. Attach the wired device on "A" points of the steel frame as shown first, and then push the whole device into junction box. 4. Confirm the device is well mounted, power on and it is ready to operate. Product Usage The actuator is operated by the local switching Touch pannels or wirelessly using Z-Wave commands. Scene Function: 1. Scene Response Device As a Scene Response device, it supports “Scene Activation CC” and “Scene Actuator Conf CC” ,which make the device can be added into any scene , and supports 255 Scene ID. In parameter item 0x10, users can configure which external switch button will respond the scene CC. 2. Scene Activate Device As a Scene Activate device, when pressing the switch button, it will send “Scene Activation” to Association Group 1 (normally associated to the gateway) to activate corresponding scenes, and the scene ID is set by configuration parameter. This function is disabled by default, to activate it, please refer to the configuration parameter table item 17-19. 3. Central Scene Activate Device As a Central Scene Activate device, it supports “Central Scene CC”. When pressing the switch button, it will send “Central Scene Notification” to Association Group 1 (normally associated to gateway). This function is always being activated and cannot be disabled. Reset to factory default XXXResetDescription Inclusion To include the device you only need to press and hold any key for 8 seconds. Exclusion To exclude the device you only need to press and hold any key for 8 seconds. NIF XXXNIF Wakeup XXXWakeupDescription Protection XXXProtection FirmwareUpdate XXXFirmwareUpdate SetAssociation XXXSetAssociation Association Groups: Group Number Maximum Nodes Description 1 1 Lifeline 2 5 Associate with Key 1 - send Basic Set Command to associated devices 5 5 Associate with Key 2 - send Basic Set Command to associated devices Configuration Parameters Parameter 2: Switch state saved or not when power failure Size: 1 Byte, Default Value: 1

Pagina 3 van 5

http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini Setting Description 0 not saved�switch will be off when powered again 1 saved�switch will keep the same state when powered again Parameter 3: ALL ON/ALL OFF Size: 1 Byte, Default Value: 255 Setting Description 0 forbid ALL ON, forbid ALL OFF 1 forbid ALL ON, allow ALL OFF 2 allow ALL ON, forbid ALL OFF 255 allow ALL ON, allow ALL OFF Parameter 4: LED Backlit brightness level Size: 1 Byte, Default Value: 10 Setting Description 0 LED disabled 1 - 10 Min level-Max level Parameter 5: Key Mode This function works for corridor or stairwell situation. Size: 1 Byte, Default Value: 0 Setting Description 0 single click to switch on/off status 1 Key default as off state. When it is turned on, then it will be turned off automatically after a time period , whic can be set in item 6 2 Key default as on state. When it is turned off, then it will be turned on automatically after a time period , whic can be set in item 6 3 hold >3s then key is on, and off once released 4 single click to switch on/off status + hold >3s then key is on, and off once released Parameter 6: Key On duration Size: 2 Byte, Default Value: 0 Setting Description 0 infinite 1 - 65535 unit sec Parameter 8: Basic CC integration setting This parameter works for integration with different gateways/systems. If do not know how to use, pls keep as default. Size: 1 Byte, Default Value: 0

Pagina 4 van 5

http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini Setting Description 0 Basic Set received�key 1 responds; Basic Get received�key 1 sends Basic Report; key 1 will not send unsolicited Basic Report�No Endpoint�to LifeLine Association 1 Basic Set received�key 1 responds; Basic Get received�key 1 sends Basic Report; key 1 will send unsolicited Basic Report�No Endpoint�to LifeLine Association 2 Basic Set received�all keys respond; Basic Get received�not reply Basic Report; All keys will not send unsolicited Basic Report�No Endpoint� to LifeLine Association 3 Basic Set received�all keys respond; Basic Get received�key 1 sends Basic Report; All keys will not send unsolicited Basic Report�No Endpoint�to LifeLine Association Parameter 16: Scene respond Size: 1 Byte, Default Value: 0 Setting Description 0 Scene respond disabled 1 Key1 respond scene Parameter 17: Key1 Scene Activate Mode Setting Size: 1 Byte, Default Value: 0 Setting Description 0 Scene activate function disabled 1 One click key1 always activate scene ID1 no matter what the status of key1 is. 2 One click key1,only activate scene ID1 when key1‘s relay output is open 3 One click key1,only activate scene ID1 when key1‘s relay output is close Parameter 18: Key1 Activate Scene ID Size: 1 Byte, Default Value: 00 Setting Description 0 Scene ID is invalid and will not send scene activate command. 1 - 255 Scene ID Parameter 19: Key1 Activate Scene Duration Size: 1 Byte, Default Value: 0 Setting Description 0 Instantly 1 - 127 Dimming durations from 1 second to 127 seconds in 1-second resolution 128 - 254 Specify dimming durations from 1 minute to 127 minutes in 1-minute resolution. Parameter 20: Key 2 Scene Activate Mode Setting Size: 1 Byte, Default Value: 0 Setting Description 0 Scene activate function disabled 1 One click key2 always activate scene ID1 no matter what the status of key2 is. 2 One click key2,only activate scene ID1 when key2‘s relay output is open 3 One click key2,only activate scene ID1 when key2‘s relay output is close

Pagina 5 van 5

http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini Parameter 21: Key2 Activate Scene ID Size: 1 Byte, Default Value: 00 Setting Description 0 Scene ID is invalid and will not send scene activate command. 1 - 255 Scene ID Parameter 22: Key2 Activate Scene Duration Size: 1 Byte, Default Value: 0 Setting Description 0 Instantly 1 - 127 Dimming durations from 1 second to 127 seconds in 1-second resolution 128 - 254 Specify dimming durations from 1 minute to 127 minutes in 1-minute resolution. Parameter 255: Factory Reset Size: 1 Byte, Default Value: 0 Setting Description 85 Factory Reset Technical Data Dimensions 86 x 86 x 39 mm Weight 180 gr Hardware Platform ZM5101 EAN 4251295700755 IP Class IP 20 Voltage 230V Load 5A Device Type On/Off Power Switch Generic Device Class Binary Switch Specific Device Class Binary Power Switch Firmware Version 05.02 Z-Wave Version 04.3e Z-Wave Product Id 0x015f.0x4121.0x5102 Frequency Europe - 868,4 Mhz Maximum transmission power 5 mW EuropeOn/Off Power Switch