Page 20 of 24 pages

MAIntenAnCe Cleaning Any maintenance of the stove should only be carried out when it is cold. Daily maintenance is limited to vacuum cleaning the stove externally, using the soft brush attachment. You can also dust the stove using a dry, soft cloth or brush. But remember, only when the stove is cold. Do not use water, spirit or any other kind of cleaner, as this will damage the lacquer. Once a year, the stove should be thoroughly serviced. The combustion chamber should be cleared of ashes and soot. The hinges and the closing hook must be greased with liquid copper fat spra ...

Page 19 of 24 pages

FIrIng In generAl Rapid or fierce heat Rapid or fierce heat is obtained by burning many small pieces of wood. Maximum amounts of fuel: The maximum allowed amount of fuel per hour is: Wood: 2,4 kg If these limits are exceeded, the stove will no longer be covered by the factory guarantee, and it may also become damaged due to excessive heat, the glass may turn white, for example. If the flue gas temperature exceeds 580oC, the HWAM® SmartControlTM will revert to safety adjustments and automatically turn down the air valves to avoid overheating. When the temperature is reduced ...

Page 16 of 24 pages

FIrIng MAnuAl - Wood Your first heating session The lacquer will be fully hardened after the stove has been used, and the door and the ash pan should be opened very carefully as there will otherwise be a risk that the gaskets will stick to the lacquer. In addi- tion the lacquer may initially give off an unpleasant odour, so make sure that the room is well ventilated. Tips about fuel Approved fuel types The wood burning stove is EN approved for combustion of wood only. It is recommended to use dried chopped wood with a water content of 12-18%. Stoking a fire with wet wood re ...

Page 13 of 24 pages

IMPORTANT FOR ALL COUNTRIES BUT UK (for UK please see separate text above) • In case of wall installation, HWAM 4510/4520 must be suspended at least 28.5 cm above an combustible floor (measured from the bottom plate of the stove). The above require- ment applies even if the floor is fitted with a floor plate. • HWAM 4510/4520 without a plinth and HWAM 4510/4520 with a low plinth must not be mounted on combustible floors. It is still considered a combustible floor even if an ember catching, non-combustible floor plate is placed on top of the combustible floor. • A non- ...

Page 12 of 24 pages

Model Weight Height Width Depth HWAM 4510c/4510m 99/97 kg 75,5 cm 50,0 cm 40,6 cm HWAM 4510c/4510m with low plinth 105/103 kg 93,0 cm 50,0 cm 40,6 cm HWAM 4510c/4510m with high plinth 109/107 kg 104,0 cm 50,0 cm 40,6 cm HWAM 4520c/4520m 94/92 kg 75,5 cm 50,0 cm 40,6 cm HWAM 4520c/4520m with low plinth 100/98 kg 93,0 cm 50,0 cm 40,6 cm HWAM 4520c/4520m with high plinth 104/102 kg 104,0 cm 50,0 cm 40,6 cm HWAM 4530c/4530m 124/122 kg 114,3 cm 50,0 cm 40,6 cm HWAM 4540c/4540m 119/117 kg 114,3 cm 50,0 cm 40,6 cm HWAM 4540c/4540m with soapstone 175/173 kg 114,3 cm 50,0 cm 40,6 cm ...

Page 23 of 24 pages

Model Direct heat output [kW] Indirect heating functionality Indirect heat output [kW] Type of heat output/room temperature control Wood logs with moisture content 12-18 % 71 Emissions Particulate matter (PM) Organic gaseous compounds (OGC) Carbon monoxide (CO) Nitrogen dioxid (NO₂) Energy efficiency index Energy efficiency class HWAM 4510 IHS, HWAM 4520 IHS, HWAM 4530 IHS, HWAM 4540 IHS, HWAM 4550 IHS, HWAM 4560 IHS 4,9 No - With electronic room temperature control Preferred fuel Yes mg/m3 (13% O2) 19 37 750 92 Product information on solid fuel local space heaters accord ...

Page 13 of 24 pages

IMPORTANT FOR ALL COUNTRIES BUT UK (for UK please see separate text above) • In case of wall installation, HWAM 4510/4520 must be suspended at least 28.5 cm above an combustible floor (measured from the bottom plate of the stove). The above require- ment applies even if the floor is fitted with a floor plate. • HWAM 4510/4520 without a plinth and HWAM 4510/4520 with a low plinth must not be mounted on combustible floors. It is still considered a combustible floor even if an ember catching, non-combustible floor plate is placed on top of the combustible floor. • A non- ...

HWAM 4510 user guide recommended for: Autopilot IHS 3120, 3640, 3610, 3055F 30/55, 3410S.

⚠️ Download Safety

The Wood stove Operation & user’s manual (24 pages) is completely safe to download (last scan date: 03/05/2026).

Related PDF Instructions for HWAM 4510:

Wood stove Equipment: Frequently Requested

Have some Questions about HWAM 4510 Device?

Get valuable and actionable advices from other HWAM 4510 device users. Describe your problem or question, regarding the using of 4510, in as much detail as possible, and other users will be able to answer you.