Network Electronics SDI-EO-D15 Series Operation & User’s Manual

Text of the manual

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 1 USER MANUAL SDI-EO-D15xx.xx SDI Fiber Optical Converter for Dense Wavelength Division Multiplexing (DWDM) Network Electronics ASA Hinderveien 4 N-3204 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: [email protected] www.network-electronics.com

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 2 Revision history The latest version is always available in pdf-format on our web-site: http://www.network-electronics.com/ Current revision of this document is the uppermost in the table below. Revision Replaces Date Change Description 1 0 02.01.08 RS T622-EO-D15xx.xx no longer available 0 C 01.05.08 RS Product release C B 01.03.23 RS Included information on the T622-EO-D15xx.xx module B A 01.03.20 RS Added correct LED status A - 01.03.09 RS Initial Revision

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 3 Index Revision history.................................................................................................................................................2 1. General............................................................................................................................................................4 2. Specifications .................................................................................................................................................5 3. Connector module .........................................................................................................................................6 3.1 Applying signals to the connector module.............................................................................................6 4. Module status ................................................................................................................................................7 4.1 GPI – Module Status Outputs.................................................................................................................7 4.2 Front Panel - Status Monitoring............................................................................................................8 5. Laser safety precautions ..............................................................................................................................9 Declaration of conformity with CE ...............................................................................................................10 General environmental requirements for flashlink® equipment.............................................................10 Notes..................................................................................................................................................................11

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 4 1. General Equalizer Distribution Amplifier Optical Transmitter SDI Input 143- 540Mbps Optical Output 2 x SDI Output Figure 1 : Block diagram of the processes inside the SDI-EO-D-15xx.xx. The flashlink  SDI to Optical converter for DWDM is a multi bit rate converter module for use together with the SDI-EO-C1 connector module. The unit can handle bit rates from 143Mbps up to 540Mbps. An on-board cable equaliser provides up to 35dB gain at 200 MHz. This will typically result in equalisation of more than 300 m of high quality coax cable at 270Mbps. The optical output is made with a DFB laser for wavelengths according to ITU-T rec. G.692. The products are not sold separately, but as parts of a flashlink® DWDM-system. The product is available in 16 versions: Part number Wavelength Part number Wavelength SDI-EO-D1549.32 SDI-EO-D1552.52 SDI-EO-D1555.75 SDI-EO-D1558.98 1549.32nm laser 1552.52nm laser 1555.75nm laser 1558.98nm laser SDI-EO-D1550.92 SDI-EO-D1554.13 SDI-EO-D1557.36 SDI-EO-D1560.61 1550.92nm laser 1554.13nm laser 1557.36nm laser 1560.61nm laser SDI-EO-D1530.33 SDI-EO-D1533.47 SDI-EO-D1536.61 SDI-EO-D1539.77 1530.33nm laser 1533.47nm laser 1536.61nm laser 1539.77nm laser SDI-EO-D1531.90 SDI-EO-D1535.04 SDI-EO-D1538.19 SDI-EO-D1541.35 1531.90nm laser 1535.04nm laser 1538.19nm laser 1541.35nm laser

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 5 2. Specifications Inputs SDI data rate NRZ: 143Mbps – 540Mbps Equalisation: Auto. up to 35dB Impedance: 75 ohm Return loss >15dB @270MHz SDI signal level: nom. 800mV Connector BNC Electrical Power: +5V DC Control: Control system for access to set-up and module status with BITE (Built-In Test Equipment). Electrical Output Number of outputs: 2 Connector: BNC Impedance: 75 ohm Return loss: > 15dB @270MHz Signal level SDI: nom. 800mV Rise/fall time: typ. 650ps Optical Output Transmission circuit fiber: Single Mode Light source: DFB Laser Optical power: 0 dBm Optical center wavelength: According to ITU-T rec. G.692 Max. wavelength drift ± 0.32nm Jitter (UI=unit interval): 0.135 UI max. @ 270 Mbps Return loss Better than 40 dB typ. Maximum reflected power: 4% Connector SC/PC acc. to SMPTE 259M

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 6 3. Connector module The SDI-EO-D15xx.xx has the same connector module as the SDI-EO: SDI-EO-C1. This module is mounted at the rear of the sub-rack. The module is shown in figure 2. Figure 2. Overview of the SDI-EO-C1 connector module 3.1 Applying signals to the connector module The connector module is the same for the SDI-EO-D and the SDI-OE cards. Apply the SDI signal to the BNC digital input connection. For monitoring purposes there are two digital outputs as well. These signals have a loop-through function where the SDI signal applied at the digital input is equalised and passed through a distribution amplifier to the two digital outputs. The signal is the same at both outputs. The optical connection is an SC/UPC connector with a return loss better than 40dB typ. According to the specification SMPTE 259M, the return loss shall be better than 26 dB.

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 7 4. Module status The status of the module can be monitored in three ways. 1. GYDA-SC controller. 2. GPI at the rear of the sub-rack. 3. LED's at the front of the sub-rack. Of these three, the GPI and the LED's are mounted on the module itself, whereas the GYDA-SC controller is a separate module giving detailed information of the status of the card. The functions of the GPI and the LED's are described in sections 4.1 and 4.2. The GYDA-SC controller is described in a separate user manual. 4.1 GPI – Module Status Outputs These outputs can be used for wiring up alarms for third party control systems. The GPI outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI connector is shown in figure 2. Electrical Maximums for GPI outputs Max current: 100mA Max voltage: 30V SDI-EO-C1 GPI pinning: Signal Name Pin # Mode Status General error status for the module. Pin 1 Open Collector LOS Electrical input signal is missing. Pin 2 Open Collector Laser Fail Laser Fail Alarm Pin 3 Open Collector Ground 0 volt pin Pin 8 0V. Figure 3: GPI Outlet

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 8 4.2 Front Panel - Status Monitoring The status of the module can be easily monitored visually by the LED's at the front of the module. The LED's are visible through the front panel as shown in figure 4. (Text not printed on the front panel). Figure 4 Diode overview of SDI-EO-D The SDI-EO-D has 3 LED's each showing a status corresponding to the GPI pinning. The position of the different LED's is shown in figure 4. Diode \ state Red LED Green LED No light Status Module is faulty Module is OK Module power is OK Module has no power LOS Loss of signal No electrical input signal. Electrical input signal present Laser fail Laser is malfunctioning Laser is OK

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 9 5. Laser safety precautions Guidelines to limit hazards from laser exposure. All the available EO units in the flashlink range include a laser. Therefore this note on laser safety should be read thoroughly. The lasers emit light at 1310 nm or 1550 nm. This means that the human eye cannot see the beam, and the blink reflex can not protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time), therefore: !! BE CAREFUL WHEN CONNECTING / DISCONNECTING FIBER PIGTAILS (ENDS). NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER/FIBER. NEVER USE MICROSCOPES, MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBER END. USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm. Instruments exist to verify light output power: Power meters, IR-cards etc. Flashlink features: The FR-2RU-10-2 is classified as Class 1 laser product according to EN 60 825-1:94/A11:96, and CFR Ch1(1997) Part 1040.10. If the front panel is removed, the FR-2RU-10-2 is classified as Class 1 laser product according to EN 60 825-1:94/A11:96, and class IIIb according to CFR Ch1(1997) Part 1040.10. Maximum output power: 5 mW. Operating wavelengths: 1310 nm or 1550 nm. < 5mW >1270nm

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 10 Declaration of conformity with CE This apparatus meets the requirements of EN 55103-1 (November 1996) with regard to emissions, and EN 55103-2 (November 1996) with regard to immunity; it thereby complies with the Electromagnetic Compatibility Directive 89/336/EEC. General environmental requirements for flashlink® equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: • Operating room temperature range 0°C to 40°C • Operating relative humidity rangeup to 90% (non-condensing) 2. Electromagnetic compatibility conditions: • Emissions EN 55103-1 (Directive 89/336/EEC) • Immunity EN 55103-2 (Directive 89/336/EEC)

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98

E-mail: [email protected] - Web: http://www.network-electronics.com Technical specifications are subject to be changed without notice 11 Notes

Other Media Converter Manuals