Lenz Digital plus LV103 Operating Manual
Read Online
Read the Lenz Digital plus LV103 Operating Manual online using the built-in PDF viewer.
Text of the manual
Art. Nr. / art. no. / Art. n° 22103
1. Auflage / 1st edition / 1e édition, 0419
1 Willkommen! ................................................................................... 3
2 Wichtige Hinweise, zuerst durchlesen! ........................................... 4
3 Digital plus Herstellergarantie ......................................................... 4
4 Technische Daten des LV103 ......................................................... 5
5 Stromversorgung einer Modelleisenbahnanlage ............................ 6
6 Die Anschlüsse ............................................................................... 7
6.1
Stromversorgung: Klemmen U,V ............................................. 7
6.2
Anschluss Netzteil .................................................................... 7
6.3
Gleisanschluss: Klemmen J,K ................................................. 8
6.4
Anschluss an die Zentrale: Klemmen C,D,E ............................ 9
7 Einstellung der Spannung am Gleis .............................................. 10
8 Einstellung des Maximalstroms am Gleis ..................................... 12
9 Aktivierung von RailCom ............................................................... 13
10 Die LED Anzeige ........................................................................... 14
11 Hilfe bei Störungen ........................................................................ 15
Diese Betriebsanleitung soll Ihnen den Gebrauch des LV103 erklären.
Wenn Sie noch Fragen haben, auf die Sie auch nach der Lektüre
dieser Information keine Antwort finden, so helfen wir Ihnen gerne
weiter. Auf vier verschiedene Arten können Sie Kontakt mit uns
aufnehmen:
Postanschrift:
Lenz Elektronik GmbH
Vogelsang 14
D-35398 Giessen
Telefon:
++49 (0) 6403 900 133
Wann Sie uns hier
erreichen, erfahren Sie
aus der Ansage
Fax:
++49 (0) 6403 900 155
Email:
[email protected]
Wenn Sie bei Problemen mit dem LV103 mit uns Kontakt aufnehmen,
sollten Sie uns neben der Problembeschreibung die Versionsnummer
des
LV103
mitteilen,
dies
hilft
unserem
Service
bei
der
Problembehebung, vielen Dank.
Alles da?
Bitte prüfen Sie, ob alles in der Verpackung enthalten ist:
LV103 Gerät und steckbare Schraubklemmen
Betriebsanleitung (dieses Heft)
Sollte ein Teil fehlen, so bitten Sie Ihren Fachhändler um vollständige
Lieferung.
Wichtige Hinweise, zuerst durchlesen!
Ihr LV103 ist eine Komponente des Digital plus by Lenz® Systems und
wurde vor Auslieferung einem intensiven Test unterzogen. Lenz
Elektronik GmbH garantiert für einen fehlerfreien Betrieb, wenn Sie die
folgenden Hinweise beachten:
Der
LV103
darf
nur
mit
anderen
Komponenten
des
Digital plus by Lenz® Systems zusammen verwendet werden. Eine
andere Verwendung als die in dieser Betriebsanleitung beschriebene
ist nicht zulässig und führt zu Verlust der Gewährleistung. Schließen
Sie den LV103 nur an die dafür vorgesehenen Geräte an. Welche
Geräte dies sind, erfahren Sie aus dieser Betriebsanleitung. Setzen
Sie den LV103 keiner Feuchtigkeit oder direkter Sonneneinstrahlung
aus.
Die Erwärmung des Gerätes im Betrieb ist normal. Sorgen Sie für eine
ausreichende Luftzirkulation um das Gerät herum, damit die interne
thermische Schutzschaltung nicht bereits im normalen Betrieb
anspricht.
WARNUNG!
Lassen Sie Ihre Modellbahnanlage nie unbeaufsichtigt in
Betrieb! Bei einem unbemerkt auftretenden Kurzschluss
besteht durch die Erwärmung Brandgefahr!
3
Digital plus Herstellergarantie
Die Digital plus Produkte der Firma Lenz Elektronik GmbH zeichnen
sich durch eine hervorragende Qualität aus. Deshalb gewähren wir
Ihnen als Verbraucher auf diese Artikel 6 Jahre Herstellergarantie ab
Kaufdatum des Produktes. Die Garantie gilt europaweit.
Im Garantiefall wenden Sie sich bitte an die Lenz Elektronik GmbH zur
Einsendung des defekten Gerätes mitsamt Kaufbeleg.
Im Garantiefall trägt die Lenz Elektronik GmbH die Kosten für eine
Reparatur und den Rückversand des defekten Gerätes. Nach der
freien Wahl der Lenz Elektronik GmbH wird entweder eine kostenlose
Reparatur oder ein Austausch des Gerätes durchgeführt. Schäden
durch Verschleiß, normalen Gebrauch oder durch unsachgemäße
Verwendung der Geräte sind von der Garantie ausgeschlossen. Die
Garantie greift demnach nur bei sachgemäßem Umgang mit dem
Produkt.
B-Ware und aufbereitete Artikel sind von der Herstellergarantie
ausgeschlossen.
Die Garantie ergänzt die gesetzlichen Gewährleistungsrechte. Es
kommt zu keiner Einschränkung des gesetzlichen Gewährleistungs-
anspruchs durch die Herstellergarantie.
4
Technische Daten des LV103
Spannungs-
versorgung
(Eingangs-
spannung)
mit Wechselspannung:
min. 14 Volt, max. 19 Volt
mit reiner Gleichspannung: min: 14 Volt, max. 24 Volt
Es ist sinnvoll, eine Eingangsspannung zu wählen, die bei
Versorgung mit Gleichspannung etwa 2 V höher, bei
Versorgung mit Wechselspannung etwa gleich groß oder
etwas kleiner ist als die eingestellte Ausgangsspannung
(Spannung am Gleis). Dies vermeidet unnötige Verlustwärme
im Gerät, die zu verfrühter thermischer Abschaltung führen
kann.
Ausgangsspannung
(Spannung am
Gleis)
Die Spannung am Gleis ist einstellbar zwischen 11 V und
22 V in Schritten von 0,5 V. Unter Belastung kann diese
Spannung je nach verwendetem Trafo niedriger sein. Ab
Werk ist eine Ausgangsspannung von 16 V eingestellt.
Ausgangsstrom
Der Ausgangsstrom wird auf maximal 5A begrenzt.
Die Strombegrenzung ist einstellbar von 2,5 A bis 5 A in
Schritten von 0,5 A.
Je nach verwendetem Transformator, dessen Spannung und
der eingestellten Gleisspannung ist der Dauerstrom, den der
Verstärker der LZV200 liefern kann, unterschiedlich.
Beispiel: Bei Trafo TR150 und Einstellung der Gleisspannung
auf 16 V beträgt der Dauerstrom 4,3 A.
Überlastschutz
Thermischer Überlastschutz.
Die Überstromabschaltung erfolgt nach ca. 200 ms bei
dauerhaftem Überstrom (z.B. Kurzschluss).
RailCom Detektor
Der LV103 ist mit einem globalen RailCom-Detektor
ausgerüstet. Dieser Detektor empfängt Daten, die von
Decodern im Kanal 2 der RailCom-Packets gesendet werden.
Diese Daten werden über die C,D,E-Leitungen an die
Zentrale LZV200 weitergeleitet.
Gehäuse
Aluminium
Abmessungen
B 120mm x H 55mm x T 120mm
Stromversorgung einer Modelleisenbahnanlage
Wie
bei
konventionell
betriebenen
Anlagen
auch,
ist
eine
ausreichende Stromversorgung der Anlage die Voraussetzung für eine
sichere Funktion des Digital-plus-Systems.
Lokomotiven, Wagenbeleuchtungen, Weichen, Signale, usw. sind
Stromverbraucher. Die Verstärker liefern den erforderlichen Strom und
gleichzeitig
auch
die
von
den
Decodern
benötigten
Steuerinformationen.
Wenn Sie bestimmen wollen, ob der maximale Strom des von Ihnen
eingesetzen Digital plus by Lenz ® Systems zur Versorgung Ihrer
Modellbahnanlage
ausreicht,
so
summieren Sie einfach den
Strombedarf der gleichzeitig fahrenden Lokomotiven und anderer
Stromverbraucher. Rechnen Sie überschlägig mit den folgenden
Werten:
-
fahrende Lokomotiven - je nach Baugröße und angehängter Last
200mA bis 2000 mA. Rechnen Sie bei der Baugröße N mit 500mA,
für die Baugröße H0 mit 1000mA und für größere Spurweiten mit
2000mA pro Lokomotive, so haben Sie meistens noch einige
Reserven.
-
stehende Lokomotiven - unbeleuchtet ca. 10 mA (in Baugröße 0
z.T. mehr), beleuchtet ca. 50mA je Birnchen oder 20 mA pro LED
-
beleuchtete Wagen - je Birnchen ca. 50 mA oder 20 mA pro LED
Ist die errechnete Summe größer als der maximal mögliche Strom
Ihres Digital plus by Lenz ® Systems, so benötigen Sie weitere
Verstärker. In diesem Fall unterteilen Sie die Anlage in mehrere
Versorgungsbereiche. Zur Versorgung dieser Bereiche setzen Sie
jeweils einen Verstärker LV103 ein.
Abb. 1: Die Anschlüsse des LV103
6.1 Stromversorgung: Klemmen U,V
Der LV103 wird über zwei Kabel an den Klemmen U und V mit dem
Transformator TR150 verbunden. In der Werkseinstellung haben Sie
16 Volt und ca. 5A am Gleis zur Verfügung.
Sollten Sie einen Trafo mit 3A (50VA) anschliessen, so stellen Sie die
Strombegrenzung bitte auch auf 3A ein. Hinweise dazu im Abschnitt 8,
S. 12.
Alternativ können Sie den LV103 auch über ein Netzteil versorgen.
Dies wird in Abschnitt 6.2, S. 7 beschrieben.
Achten Sie darauf, dass Sie nur eine Stromversorgungsart
angeschlossen haben. Also entweder einen Transformator
ODER ein Netzteil verwenden.
6.2 Anschluss Netzteil
Als alternativen Stromanschluß können Sie ein handelsübliches
Netzteil benutzen. Der Pindurchmesser beträgt 2,5 mm. Plus und
minus müssen nicht beachtet werden. Das Netzteil sollte min 2,5 A
und höchstens 5A liefern. Stellen Sie die Strombegrenzung des
Verstärkers bitte entsprechend ein (siehe Abschnitt 8, S. 12)
Als Eingangsspannung sind folgende Werte zulässig:
mit Wechselspannung:
min. 14 Volt, max. 19 Volt
mit reiner Gleichspannung:
min: 14 Volt, max. 24 Volt
Achten Sie darauf, dass Sie nur eine Stromversorgungsart
angeschlossen haben. Also entweder einen Transformator
ODER ein Netzteil verwenden.
6.3 Gleisanschluss: Klemmen J,K
Verwenden
Sie
zum
Anschluss
der
Gleise
nur
Kabel
mit
ausreichendem Querschnitt (empfohlen min. 0,25 mm2) und verdrillen
Sie diese Kabel. Bei ausgedehnten Fahrstrecken benötigen Sie in
regelmäßigen Abständen zusätzliche Fahrstromeinspeisungen.
Abb. 2: Anschluss 2-Leiter-Gleise
Abb. 3: Anschluss Gleis mit Mittelleiter
Es dürfen keine Kondensatoren zur Funkentstörung in der
Gleisanlage eingebaut sein. Diese Kondensatoren sind nur
beim konventionellen Betrieb für die Funkentstörung
notwendig. Beim Digital plus System verfälscht er jedoch
das Datenformat und die einwandfreie Datenübertragung
wird beeinträchtigt.
Wichtig:
Ein gemischter Digitalbetrieb über Ober- und Unterleitung ist nicht zu-
lässig. Steht die Lokomotive bei dieser Betriebsart in der falschen
Richtung auf dem Gleis (dies kann z.B. nach Durchfahren einer Kehr-
schleife der Fall sein), kann der eingebaute Lokempfänger durch
Überspannung zerstört werden! Wir empfehlen den Betrieb mit
Stromabnahme
durch
das
Gleis
(Radkontakte),
da
die
Kontaktsicherheit (und damit die Übertragung der Digitalsignale zum
Lokempfänger) wesentlich sicherer ist als bei Oberleitung.
Die Stromkreise mehrerer Verstärker untereinander müssen unbedingt
gleiche Polarität haben. Die Klemme J des einen Verstärker und die
Klemme J des nächsten Verstärker müssen also an die jeweils gleiche
Gleisseite angeschlossen werden. Sonst treten beim Überfahren der
Trennstellen Kurzschlüsse auf.
Wenn Sie mehrere Versorgungsbereiche auf Ihrer Modellbahn haben,
so müssen Sie die Spannung am Gleis (Ausgangsspannung) bei den
eingesetzten Verstärkern auf den gleichen Wert einstellen (vgl.
Abschnitt 6).
6.4 Anschluss an die Zentrale: Klemmen C,D,E
Über die Klemmen C und D erhält der Verstärker LV103 das
Datenformat von der Zentrale (LZ100, LZV100, LZV200). Die
Klemmen C und D werden mit den gleichnamigen Klemmen der
Zentrale verbunden. Verwenden Sie am besten ein verdrilltes Kabel.
Wird die Klemme E des Verstärkers mit der Klemme E der Zentrale
verbunden, teilt der Leistungsverstärker der Zentrale eine Überlastung
oder einen Kurzschluss mit. Die Zentrale schaltet dann auch alle
anderen Verstärker ab und teilt dies über das XpressNet allen
angeschlossenen Eingabegeräten mit.
Über die Klemme E erfolgt außerdem die Übertragung vom
eingebauten globalen Railcom-Detektor an die LZV200.
Abb. 4: Anschluss eines Verstärkers LV103 an die LZV200.
Abb. 5: Anschluss eines Verstärkers LV103 an die LZV100.
7
Einstellung der Spannung am Gleis
Der
LV103
verfügt
über
eine
einstellbare
Begrenzung
der
Gleisspannung. Begrenzung bedeutet, dass die eingestellte Spannung
nicht überschritten wird. Die Spannung am Gleis kann aber in
Abhängigkeit von der Spannung und der Leistungsfähigkeit des
versorgenden Trafos tatsächlich geringer sein als der eingestellte
Wert.
Je nach Baugröße, für die Sie den LV103 verwenden, kann eine
Veränderung der werkseitig eingestellten Spannung am Gleis
(Klemmen J und K) vorteilhaft sein. Insbesondere die größeren
Spurweiten werden mitunter mit geringfügig höheren Spannungen
betrieben, während im Bereich der Spur N eher eine niedrigere
Ausgangsspannung gewünscht ist. Die Trafospannung sollte der
gewünschten Gleisspannung möglichst angepasst sein. Eine zu hohe
Trafospannung erzeugt nur unnötige Verlustwärme im Verstärker, dies
führt zu frühzeitigem Abschalten, bevor der maximale Ausgangsstrom
erreicht ist.
Werkseitig ist der Ausgang des LV103 auf 16V eingestellt, Sie können
einen Bereich zwischen 11 V und 22 V wählen.
Durch nachfolgend beschriebenes Vorgehen verändern Sie die
Gleisspannung sowohl im Verstärker LV103, als auch in der Zentrale
LZV200/LZV100 und in jedem an den Klemmen CDE der Zentrale
angeschlossenen Verstärker LV103/LV102.
Zur Einstellung der Gleisspannung wird "PoM", das "Programmieren
während des Betriebes" verwendet. Bevor Sie die Einstellung
vornehmen, sollten Sie sich mit der Bedienung von PoM mit Ihrem
Handregler LH100 oder LH101 vertraut machen.
Gehen Sie dann wie folgt vor:
Wählen
Sie
am
Handregler
eine
beliebige
Lokadresse
Keine Angst: Wenn während der Spannungseinstellung eine Lok mit der oben
verwendeten Adresse auf dem Gleis steht, so ändern sich deren Einstellungen
nicht, da die CV7 im Lokdecoder nur gelesen, aber nicht verändert werden kann.
Wechseln Sie dann zu "PoM".
Wählen Sie CV7.
Programmieren Sie den Wert 50 in CV7. Hiermit wird die LZV200
in den Einstellmodus versetzt, die LED der LZV200 und von ev.
angeschlossenen LV102/103 zeigen einen Doppelblitz.
Programmieren Sie innerhalb von 15 Sekunden den Wert für die
gewünschte Ausgangsspannung (vgl. unten) in CV7. Die LED
leuchtet wieder konstant, die Spannung am Gleis ist geändert.
Welchen Wert Sie in CV7 einprogrammieren müssen um eine
bestimmte Spannung am Ausgang (UA) einzustellen sehen Sie in der
folgenden Tabelle:
UA (V)
CV7
UA (V)
CV7
UA (V)
CV7
11
22
15
30
19
38
11,5
23
15,5
31
19,5
39
12
24
16
32
20
40
12,5
25
16,5
33
20,5
41
13
26
17
34
21
42
13,5
27
17,5
35
21,5
43
14
28
18
36
22
44
14,5
29
18,5
37
Einstellung des Maximalstroms am Gleis
Werkseitig ist die Strombegrenzung des LV103 auf 5A eingestellt, Sie
können einen Bereich zwischen 2,5 A und 5A wählen.
Durch nachfolgend beschriebenes Vorgehen verändern Sie den
Maximalstrom sowohl im Verstärker LV103, als auch in der Zentrale
LZV200/LZV100 und in jedem an den Klemmen CDE der Zentrale
angeschlossenen Verstärker LV103/LV102.
Zur
Einstellung
des
Ausgangsstromes
wird
"PoM",
das
"Programmieren während des Betriebes" verwendet. Bevor Sie die
Einstellung vornehmen, sollten Sie sich mit der Bedienung von PoM
mit Ihrem Handregler LH100 oder LH101 vertraut machen.
Gehen Sie dann wie folgt vor:
Wählen
Sie
am
Handregler
eine
beliebige
Lokadresse
Keine Angst: Wenn während der Stromeinstellung eine Lok mit der oben
verwendeten Adresse auf dem Gleis steht, so ändern sich deren Einstellungen
nicht, da die CV7 im Lokdecoder nur gelesen, aber nicht verändert werden kann.)
Wechseln Sie dann zu "PoM"
Wählen Sie CV7.
Programmieren Sie den Wert 50 in CV7. Hiermit wird die LZV200
in den Einstellmodus versetzt, die LED der LZV200 und von ev.
angeschlossenen LV103 zeigen einen Doppelblitz.
Programmieren Sie innerhalb von 15 Sekunden den Wert für den
gewünschten Ausgangsstrom x2 (für 2,5A = Wert 5 nehmen ) (vgl.
unten) in CV7. Die LED leuchtet wieder konstant, der Strom am
Gleis ist auf diesen Wert begrenzt.
Welchen Wert Sie in CV7 einprogrammieren müssen, um einen
bestimmten Stromwert am Ausgang einzustellen, sehen Sie in der
folgenden Tabelle:
Stromwert in A:
Wert in CV 7:
2,5
5
3
6
3,5
7
4
8
4,5
9
5
10
Zur Verwendung eines 3A Trafos stellen Sie bitte einen maximalen
Strom am Gleis von 3A ein. Auch bei Verwendung eines Netzteils
stellen Sie bitte die Strombegrenzung passend ein.
9
Aktivierung von RailCom
Hinweis: In der Werkseinstellung ist RailCom bereits aktiviert!
Zum Aktivieren von RailCom wird "PoM", das "Programmieren
während des Betriebes" verwendet. Bevor Sie die Einstellung
vornehmen, sollten Sie sich mit der Bedienung von PoM mit Ihrem
Handregler LH100, LH101 oder LH90 vertraut machen. Die LZV100
muß zum Aktivieren von RailCom eingeschaltet sein.
Durch nachfolgend beschriebenes Vorgehen schalten Sie die
Austastlücke sowohl im Verstärker LV103, als auch in der Zentrale
LZV200/LZV100 und in jedem an den Klemmen CDE der Zentrale
angeschlossenen Verstärker LV103 und LV102 ein.
Gehen Sie bitte wie folgt vor:
Wählen Sie am Handregler eine beliebige Lokadresse. Keine
Angst: Wenn während der Aktivierung eine Lok mit der oben
verwendeten Adresse auf dem Gleis steht, so ändern sich deren
Einstellungen nicht, da die CV7 im Lokdecoder nur gelesen, aber
nicht verändert werden kann.
Wechseln Sie dann zu "PoM"
Wählen Sie CV7
Programmieren Sie den Wert 50 in CV7. Hiermit wird die Zentrale
und der LV103 in den Einstellmodus versetzt, die LED der
Zentrale / des LV103 zeigt einen Doppelblitz.
Programmieren Sie innerhalb von 15 Sekunden den Wert 93 zur
Aktivierung von RailCom in CV7. Die LED leuchtet wieder
konstant, Railcom ist aktiviert.
Wenn Sie RailCom wieder deaktivieren (die Austastlücke wieder
ausschalten) wollen, gehen Sie bitte wie folgt vor:
Wechseln Sie bitte zu "PoM"
Wählen Sie CV7
Programmieren Sie den Wert 50 in CV7. Hiermit werden die
Zentrale und der LV103 in den Einstellmodus versetzt, die LED der
LZV100/LZV200 und des LV103 zeigt wieder einen Doppelblitz.
Programmieren Sie innerhalb von 15 Sekunden den Wert 92 zum
Ausschalten von RailCom in CV7. Die LED leuchtet wieder
konstant, Railcom ist deaktiviert.
10 Die LED Anzeige
Die verschiedenen Betriebszustände des LV103 werden durch die
LED auf der Frontplatte angezeigt:
LED dauernd an
Alles ok, Gerät in normalem Betrieb
LED blinkt langsam
Klemmen C und D sind nicht angeschlossen
oder
Notaus, Gleisspannung wurde an einem
Bediengerät ausgeschaltet
oder
Zentrale nicht betriebsbereit
LED blinkt schnell
Kurzschluss auf der Anlage, Spannung zum
Gleis wurde abgeschaltet
oder
Übertemperatur im Verstärker
LED zeigt Doppelblitz: Es wurde ein Programmiervorgang mit PoM
begonnen (s. Einstellung der Gleisspannung)
11 Hilfe bei Störungen
Fehler
Ursache
Beseitigung
LV103 ist nicht
betriebsbereit (LED
leuchtet nicht)
Stromversorgung
unterbrochen, Netzstecker
des Transformators nicht
eingesteckt
Verdrahtung zwischen
Trafo und LV103 prüfen,
Netzstecker einstecken
LED blinkt
Es liegt ein Kurzschluß auf
der Gleisanlage vor
Beseitigen Sie den
Kurzschluß
Es liegt eine Überlastung
vor
Teilen Sie die Anlage in
mehrere
Versorgungsabschnitte und
versorgen Sie diese mit
zusätzlichen
Verstärkern / Trans-
formatoren
LV103 ist betriebsbereit
(LED leuchtet), aber
Lokomotiven fahren nicht,
Weichen und Signale
lassen sich nicht schalten
Die Verbindung vom
Verstärker zum Gleis
und/oder den
Schaltempfängern ist
unterbrochen (Klemmen J
und K nicht angeschlossen)
Überprüfen und korrigieren
Sie die Verbindungen
1 Welcome! ...................................................................................... 17
2 Important advice, please read first! ............................................... 18
3 Digital plus manufacturer's warranty ............................................. 18
4 Technical data of the LV103 ......................................................... 19
5 The power supply of a model railway layout ................................. 19
6 The connections ............................................................................ 20
6.1
Power supply: terminals U,V .................................................. 20
6.2
Connection power supply ....................................................... 21
6.3
Track connection: terminals J,K ............................................. 21
6.4
Connection to the command station: terminals C,D,E ........... 22
7 Setting the track voltage................................................................ 24
8 Setting the maximum output current to the track .......................... 25
9 RailCom: Activating the cutout in the LV103: ................................ 26
10 The LED display ............................................................................ 27
11 Help in case of malfunctions ......................................................... 28
If you still have unanswered questions even after reading this
operating manual, then please contact us. There are four different
ways of contacting Lenz Elektronik GmbH:
Postal
address:
Lenz Elektronik GmbH
Vogelsang 14
D-35398 Giessen
Telephone:
++49 (0) 6403 900 133
The recorded message
will inform you of times
when we are available for
consultation
Fax:
++49 (0) 6403 900 155
E-mail:
[email protected]
If you have any problems with the LV103, just contact us, stating the
following information together with a description of the problem:
Version number of the LV103
Correct designation, version and service number of the connected
XpressNet devices
This will help our service department to resolve the problem. Thank
you.
All present?
Please check whether all the components have been delivered:
LV103 device
Operating manual (this booklet)
If any component is missing, please ask your specialist supplier for a
supplementary delivery.
Important advice, please read first!
Your LV103 is a component of the Digital plus by Lenz® system and
was submitted to intensive testing before delivery. Lenz Elektronik
GmbH guarantees fault-free operation provided you follow the advice
given below:
The LV103 is only authorised for operation with other components of
the Digital plus by Lenz® system. Any use other than that described in
this operating manual is not permitted and all guarantees will become
invalid, if the LV103 is used inappropriately. Connect your LV103 only
to devices which are designated for such connection. This operating
manual will inform you which devices are suitable. Do not expose the
LV103 to damp or direct sunlight. The heat produced by the device
during operation is normal. You must provide sufficient air circulation
around the device in order to prevent the internal thermal protective
system from reacting prematurely, that is, during normal operation.
WARNING!
Do not leave your model railway system unsupervised
while in operation! If a short-circuit goes unnoticed,
the heat produced creates a fire risk!
3
Digital plus manufacturer's warranty
Digital plus products of Lenz Elektronik GmbH are characterized by
outstanding quality. Therefore we grant you as consumer a 6-year
manufacturer’s warranty on these items from date of purchase of the
product. The guarantee applies throughout Europe.
In the case of warranty, please contact Lenz Elektronik GmbH to
return the defective device including proof of purchase.
In case of warranty Lenz Elektronik GmbH bears the costs for repair
and return shipment of the defective device. Based on the free choice
of Lenz Elektronik GmbH either a free repair or an exchange of the
device will be carried out. Damage caused by wear, normal use or
improper use of the equipment is excluded from the warranty. The
guarantee therefore only applies if the product is handled properly.
B-stock and refurbished articles are excluded from the manufacturer's
warranty.
The guarantee supplements the statutory warranty rights. There is no
limitation of the legal warranty claim by the manufacturer's warranty.
Technical data of the LV103
Power supply
(input voltage)
with AC:
min. 14 Volt, max. 19 Volt
with pure DC:
min. 14 Volt, max. 24 Volt
When supplied with DC, it makes sense to select an input
voltage which is approx. 2 V higher than the set output
voltage (voltage on the track) or, if supplied with AC, equally
high or slightly lower. This avoids an unnecessary loss of
heat in the device which in turn could lead to an early thermal
switch off.
Output voltage
(track voltage)
The voltage at the track is adjustable between 11 V and 22 V
in steps of 0,5 V. In case of a loads, this voltage can be lower
depending on the transformer used. The factory voltage
setting is 16V.
Output current
The output current is limited to a maximum of 5A.
It is adjustable from 2.5 A to 5 A in steps of 0.5 A.
Depending on the transformer used, as well as its voltage
and the set track voltage, the constant current, which the
amplifier of the LZV 200 can supply, varies.
Example: When using the transformer TR150 and a track
voltage of 16V, the constant current is 4.3 A.
Overload protection
Thermal overload protection. The switching off of the
overload occurs after approx. 200 ms in case of constant
overcurrent (e.g. short-circuit).
RailCom Detector
The LV103 is equipped with a global RailCom detector. This
detector receives data sent by decoders in channel 2 of the
RailCom packets.
This data is forwarded via the C,D lines to the LZV200 central
unit.
Housing
Aluminium
Dimensions
W 120mm x H 55mm x D 120mm
5
The power supply of a model railway layout
As with conventionally operated systems and layouts, a sufficient
supply of electricity to the system is a precondition for the sure and
safe functioning of the Digital plus by Lenz ® system.
Locomotives, (coach) lights, points, signals etc. are power consumers.
The amplifiers supply this power and at the same time the control
information required by the decoders.
To find out whether the maximum current of the Digital plus by Lenz ®
system used is sufficient for the supply of your model railway system,
simply add up the power consumption of all locomotives running at the
same time as well as that of all other consumers. Use the following
approximate values for your calculation:
-
running locomotives – depending on gauge and attached load, the
power consumption ranges from 200mA to 2000mA. Calculate per
locomotive 500mA for gauge N, 1000mA for gauge H0 and
2000mA for larger gauges. This ensures that you still have some
reserve left.
-
standing locomotives – not illuminated 10 mA, illuminated approx.
50mA for each bulb.
-
illuminated wagons – each bulb approx. 50mA or 20mA when using
LEDs.
If the calculated sum exceeds the maximum current available from the
Digital plus by Lenz ® system used, you will need more amplifiers. If
this is the case, divide the layout into several supply areas. Use an
amplifier LV103 for supplying each of these areas.
6
The connections
Fig. 1: The connections of the LV103
6.1 Power supply: terminals U,V
The LV103 is connected to the transformer TR150 via two cables at
the terminals U and V. In factory setting, you have 16 volts and approx.
5A available on the track.
If you connect a transformer with 3 A (50VA), please also set the
current limitation to 3A. See section 8, page 25 for more information.
Alternatively, you can also supply the LV103 via a power supply unit.
This is described in section 6.2, p. 21.
Only one kind of power supply may be connected tot he
LZV200. Either a transformer or a power supply unit.
6.2 Connection power supply
As an alternative power connection you can use a commercially
available power supply. The pin diameter must be 2.5 mm. Plus and
minus do not have to be observed. The power supply should supply
min. 2.5 A and max. 5A.
The following values are permissible as input voltage:
with alternating voltage:
min. 14 Volt, max. 19 Volt
with pure DC voltage:
min: 14 Volt, max. 24 Volt.
Make sure that you have connected only one type of power
supply. So either use a transformer OR a power supply.
6.3 Track connection: terminals J,K
Only use cables with sufficiently large cross-sections to connect the
tracks and then twist this cable (we recommend 0.25 mm2). For
extended routes you need additional points of current supply at regular
intervals.
Fig. 2: Connection 2-wire tracks
Fig. 3: Connection track with neutral wire
No radio interference suppression capacitor may be
installed in the track system. This capacitor is necessary
only for the interference suppression in conventional
operation. If used with the Digital plus system, however, it
would distort the data format and interfere with the fault-
free transmission of data.
Important:
A mixed digital operation using overhead and track lines is not
permitted. In this type of operational mode, the installed locomotive
decoder can be destroyed by overvoltage if the locomotive is sitting on
the track in the wrong direction (which might be the case e.g. after
having driven through a terminal-loop)! We recommend operation
using track pick-up, because the reliability of contact (and therefore
the transmission of digital signals to the locomotive decoder) is
substantially greater than it is when operating with overhead lines.
It is absolutely necessary that the electric circuits of all amplifiers are
of the same polarity. Thus, terminal J of one and terminal J of the next
amplifier must be connected to the same side of the track in question.
Otherwise short-circuits will occur when driving over sectioning points.
If you have several supply areas on your model railway layout, you will
have to set the track voltage (output voltage) for the amplifiers in use
to the same value (see Section 6).
6.4 Connection to the command station: terminals
C,D,E
The amplifier LV103 receives the data format from the command
station via the terminals C and D (LZ100, LZV100, LZV200). The
terminals are connected to the terminals of the other amplifiers, which
have the same name. We recommend the use of a twisted cable.
If terminal E of the amplifier is connected to terminal E of the
command station, the amplifier will communicate an overload or a
short-circuit to the command station. The command station then
switches off all other amplifiers and communicates this to all
connected input devices via the XpressNet.
Terminal E is also used for transmission from the built-in global
Railcom detector to the LZV200.
Fig. 4: Connecting an amplifier LV103 to the LZV200.
Fig. 5: Connecting an amplifier LV103 to the LZV100.
Setting the track voltage
The limit of the track voltage of the LV103 can be set. However, the
track voltage may actually be lower than the set value, depending on
the voltage and the capacity of the transformer supplying the power.
Depending on the gauge for which the LV103 is used, changing the
factory setting of the track voltage may be advantageous (terminals J
and K). Larger gauges in particular, are often operated with slightly
higher voltages or if you want a lower output voltage for gauge N. If
possible, the transformer voltage should be adjusted to the desired
track voltage. A transformer voltage which is too high leads to an
unnecessary loss of heat in the amplifier which in turn leads to an early
switch-off before the maximum output voltage is reached.
The factory setting for the output of the LV103 is 16V; you can choose
a range between 11V and 22V.
If you have several supply areas on your model railway layout, you will
have to set the track voltage (output voltage) for the amplifiers in use
to the same value.
"PoM", "Programming in operational mode" is used to set the track
voltage. Before making the settings, you should familiarise yourself
with using PoM with your manual control LH100, LH101 or LH90.
The LV103 must be connected to terminals C and D in order for the
track voltage to be set. The command station and the amplifier LV103
must be switched on.
Proceed as follows:
Select any locomotive address on the manual control (Don’t
worry: If a locomotive with the address used above is placed on a
track while you are setting the voltage, its settings will not be
affected, since CV7 can only be read in the locomotive decoder,
but not changed.)
Change over to "PoM "
Select CV7.
Program the value 50 into CV7. This switches the LZV100 into
setting mode; the LED of the LZV100 shows a double-flash.
You have 15 seconds to program the value for the desired output
voltage (compare below) into CV7. The LED will shine constantly
and the track voltage is altered.
See the following table for the value you will have to program into CV7
in order to set a certain voltage at the output (UA):
UA (V)
CV7
UA (V)
CV7
UA (V)
CV7
11
22
15
30
19
38
11.5
23
15.5
31
19.5
39
12
24
16
32
20
40
12.5
25
16.5
33
20.5
41
13
26
17
34
21
42
13.5
27
17.5
35
21.5
43
14
28
18
36
22
44
14.5
29
18.5
37
8
Setting the maximum output current to the track
Factory-made, the output of the LV103 is set to 5A; you can select a
range between 2.5A and 5A.
To set the output current "PoM", "Programming during operation" is
used. Before making the setting, you should familiarize yourself with
the operation of PoM with your LH100 or LH101 handset controller.
Then proceed as follows:
Select any locomotive address on the handset control (Don't
worry: If a locomotive with the address used above is on the
track during current setting, its settings will not change, since
the CV7 in the locomotive decoder can only be read, but not
changed.)
Then switch to "PoM".
Select CV7.
Program value 50 in CV7. This sets the LV103 into setting
mode, the LED of the LV103 and of any connected LV102/103
show a double flash.
Within 15 seconds, program the value for the desired output
current x2 (for 2.5A = take value 5 ) (see below) in CV7. The
LED lights up constantly again, the track current is limited to this
value.
The following chart shows which value you have to program in CV7 to
set a certain current value at the output:
current (A):
Value in CV7:
2,5
5
3
6
3,5
7
4
8
4,5
9
5
10
To use a 3A transformer, please set a maximum current on the
track of 3A.
9
RailCom: Activating the cutout in the LV103:
Important Note: RailCom is enabled in the factory default setting!
Use "PoM" ("Programming in operational mode") to activate RailCom.
Before making any settings, familiarise yourself with PoM practices in
combination with the manual control LH100 or LH90. When activating
the RailCom function, the LZV100 must be switched on.
The following procedure activates the blanking interval (cutout) both in
the amplifier component of the LZV100/LZV200 as well as in the each
of the LV103/LV102 amplifiers that are connected to the terminals
CDE of the LZV100/LZV200.
When using a command station LZ100 (from software version 3.5),
you will use this command station to activate the blanking interval
(cutout) in the LV103 amplifiers that are connected to the terminals
CDE.
Proceed as follows:
Select any locomotive address on the manual control. Don’t worry:
If a locomotive with the selected address is placed on the track
during activation, its settings will not be affected because CV7 can
only be read but not changed.
Change to "PoM"
Select CV7
Program
the
value
50
into
CV7.
This
switches
the
LZV100/LZV200/LV103 into setting mode; the LED of the
LZV100/LZV200/LV103 shows a double-flash.
You have 15 seconds to program the value 93 for activating the
RailCom function into CV7. The LED will shine constantly and
RailCom is activated.
If you want to deactivate RailCom (i.e. disable the blanking interval
(cutout)), proceed as follows:
Change to "PoM"
Select CV7
Program
the
value
50
into
CV7.
This
switches
the
LZV100/LZV200/LV103 into setting mode; again, the LEDs show a
double-flash.
You have 15 seconds to program the value 92 for deactivating the
RailCom function into CV7. Again, the LED will shine constantly
and RailCom is deactivated.
10 The LED display
The various operating statuses of the LV103 are indicated by the LEDs
on the front plate:
LED shines constantly Everything ok, device in normal operation
LED flashes slowly
Terminals C and D are not connected
or
Emergency stop, track voltage switched off at
an operating device
or
The command station is not ready for
operation
LED flashes quickly
Emergency stop, track voltage switched off
or
Overheating of amplifier
LED double-flashes:
A programming procedure was started by
means of PoM (see “Setting the track
voltage”)
11 Help in case of malfunctions
Fault
Possible cause
Elimination of problem
LV103 is not ready for
operation (LED does not
shine)
Electric power supply is
interrupted. Transformer
mains-plug not plugged in.
Check wiring between
transformer and LV103,
plug in transformer mains-
plug.
LED flashes slowly.
There has been a short-
circuit on the track system.
Deal with the short-circuit.
There is overloading.
Divide the system into
several coverage areas and
supply them with additional
amplifiers / transformers.
LV103 is ready for
operation (LED shines),
locomotives do not run,
points and signals can not
be switched.
The connection of the
amplifier and the track and
/ or the switch decoders is
interrupted (terminals J and
K not connected).
Check and correct the
connections.
Table des matières
1 Bienvenue ! ................................................................................... 30
2 Remarques importantes, à lire avant toute chose ! ...................... 31
3 Garantie du fabricant Digital plus .................................................. 31
4 Données techniques du LV103 ..................................................... 32
5 Alimentation en courant d'un réseau ferroviaire miniature ............ 33
6 Les connexions ............................................................................. 34
6.1
Alimentation en courant : bornes U, V ................................... 34
6.2
Alimentation en courant ......................................................... 34
6.3
Connexion à la voie : bornes J, K .......................................... 35
6.4
Connexion à la centrale : bornes C, D, E ............................... 36
7 Réglage de la tension sur la voie .................................................. 37
8 Réglage du courant maximum sur la piste ................................... 39
9 RailCom: Activation de l'intervalle de suppression avec le
LV103 :................................................................................................ 40
10 La diode indicatrice ....................................................................... 42
11 Aide en cas de panne ................................................................... 43
Ce mode d'emploi doit vous permettre d'y voir clair dans l'utilisation du
LV103. Si vous désirez poser des questions à propos de sujets sur
lesquels cette information ne vous donne pas de réponse, veuillez
nous contacter. Il existe différentes possibilités de nous contacter.
Adresse
postale :
Lenz Elektronik GmbH
Vogelsang 14
D-35398 Giessen
Téléphone :
++49 (0) 6403 900 133
Quand vous nous
téléphonez, veuillez suivre
les indications données au
téléphone.
Télécopie :
++49 (0) 6403 900 155
Email :
[email protected]
Si vous nous contactez à propos de problèmes rencontrés avec le
LV103, veuillez nous communiquer les renseignements suivants en
sus de la description des problèmes :
Numéro de version du LV103
Désignation exacte, numéro de version et numéro de service des
appareils XpressNet raccordés.
Ceci aidera nos services à résoudre les problèmes.
Tout est-il là ?
Veuillez vérifier si tous les composants sont présents :
Appareil LV103
Mode d'emploi (cette information)
Si une pièce est manquante, demandez à votre détaillant de compléter
la livraison.
Remarques importantes, à lire avant toute chose !
Votre LV103 est un composant du système Digital plus by Lenz® et il a
subi un test intensif avant sa mise sur le marché. Lenz Elektronik
GmbH garantit un fonctionnement impeccable si vous respectez les
règles suivantes.
Le LV103 ne peut être utilisé qu’avec les autres composants du
système Digital plus by Lenz®. Toute autre utilisation que celle qui est
décrite dans ce mode d'emploi n'est pas permise et entraînera de
facto l'annulation de la garantie. Raccordez votre LV103 aux appareils
prévus pour lui et dont vous trouverez la description dans ce mode
d'emploi. N'exposez pas le LV103 à l'humidité ni au rayonnement
solaire direct.
L'échauffement de l'appareil en service est normal. Veillez cependant
à ce qu'existe une circulation d'air suffisante autour de lui afin de
prévenir un déclenchement intempestif de la protection thermique en
service normal.
AVERTISSEMENT !
N'abandonnez
jamais
votre
réseau
ferroviaire
miniature
sans
surveillance
lorsqu'il
est
en
fonctionnement ! S'il devait survenir un court-circuit,
l'échauffement qui s'ensuivrait pourrait entraîner un
incendie !
3
Garantie du fabricant Digital plus
Les produits Digital plus de l'entreprise Lenz Elektronik GmbH se
distinguent par une excellente qualité. C'est la raison pour laquelle
Lenz Elektronik GmbH garantit sur ces articles une garantie du
fabricant de 6 ans à compter de la date d'achat du produit. La garantie
est valable dans toute l'Europe.
En cas de recours à la garantie, veuillez vous contacter Lenz
Elektronik GmbH pour retourner l’article défectueux avec le ticket de
caisse.
En cas de réclamation au titre de la garantie, Lenz Elektronik GmbH
supporte les frais de réparation et le retour de l’article défectueux.
Selon le cas, Lenz Elektronik GmbH procédera soit à une réparation
gratuite, soit à un échange de l’article. Tous les dégâts causés par une
usure et une dégradation normale ou une utilisation inappropriée de
l'équipement sont exclus de la garantie. La garantie ne s'applique
donc que si le produit est manipulé correctement.
Produits de second choix et d'occasion sont exclus de la garantie du
fabricant.
La garantie complète les droits de garantie légaux. Les droits de
garantie légaux ne sont pas affectés par la garantie du fabricant.
4
Données techniques du LV103
Tension
d'alimentation
(tension d'entrée)
Avec courant alternatif :
min. 14 volts, max. 19 volts.
Avec courant continu pur :
min. 14 volts, max. 24 volts.
Il tombe sous le sens qu'il faut sélectionner une tension
d'entrée qui soit égale ou un peu plus petite (2 volts environ
avec du courant continu) que la tension de sortie (tension sur
la voie). Ceci pour éviter une dissipation calorifique
indésirable dans l'appareil qui pourrait engendrer un
déclenchement thermique prématuré.
Tension de sortie
(tension sur la voie)
La tension sur la voie est réglable entre 11 V et 22 V par
incrément de 0,5 V. En usine, la tension de sortie est réglée
sur 16 V.
Courant de sortie
Le courant de sortie est limité à 5 A.
L'intensité est réglable de 2,5 A à 5 A par incrément de 0,5 A.
En fonction du transformateur utilisé, de la tension qu'il
délivre et du réglage de la tension sur la voie, le courant
permanent (l'intensité) que l'amplificateur de la LZV200 peut
délivrer, varie.
Exemple : avec un transformateur TR150 et une tension de
sortie réglée sur 16 V, le courant permanent pouvant être
délivré est de 4,3 A.
Protection contre
les surcharges
Protection thermique. En cas de surcharge permanente (par
ex. court-circuit), l'interruption de courant survient après un
laps de temps d'environ 200 ms.
Détecteur RailCom
La LZV200 est équipée d'un détecteur RailCom global. Ce
détecteur reçoit les données qui sont envoyées par les
décodeurs dans le canal 2 RailCom.
Ces données sont transmises par les lignes C,D à la centrale
LZV200.
Boîtier
Aluminium.
Dimensions
Larg. 120 mm x haut. 55 mm x prof. 120 mm.
Alimentation en courant d'un réseau ferroviaire
miniature
Tout comme sur les réseaux exploités conventionnellement, une
alimentation suffisante du réseau est une condition indispensable au
bon fonctionnement du système Digital-plus.
Les locomotives, les éclairages de voitures, les aiguillages, les
signaux, etc. sont des consommateurs de courant. L'amplificateur
délivre ce courant ainsi que les informations de pilotage et de
commande nécessaires aux décodeurs.
Si vous voulez estimer le courant maximal consommé par le système
Digital plus by Lenz ® que vous avez installé sur votre réseau,
additionnez la consommation de toutes les locomotives roulant
simultanément sur votre réseau et de tous les autres consommateurs
de courant. Voici comment effectuer un calcul approximatif :
-
Locomotives en marche : 200 mA à 2000 mA selon l'échelle de
réduction et la charge remorquée. Comptez, par locomotive, 500
mA pour l'échelle N, 1000 mA pour l'échelle H0 et 2000 mA pour
les échelles plus grandes. Généralement, il reste encore une
réserve.
-
Locomotives à l'arrêt : non éclairées, ca. 10 mA ; éclairées, environ
50 mA par ampoule.
-
Voitures éclairées : environ 50 mA par ampoule.
Si le total des consommations est plus grand que le courant maximal
que peut délivrer votre système Digital plus by Lenz ®, vous devrez
installer un ou plusieurs amplificateurs supplémentaires. Dans ce cas,
divisez votre réseau de voies en deux ou plusieurs zones et alimentez
séparément chacune d'entre elles à l'aide d'un amplificateur LV103.
Figure 1 : Les connexions du LV103.
6.1 Alimentation en courant : bornes U, V
La LZV200 est reliée au transformateur TR150 par deux câbles aux
bornes U et V. En usine, les réglages sont 16 volts et environ 5 A
disponibles sur la voie.
Si vous raccordez un transformateur débitant 3 A (50 VA), veuillez
également régler la limite de courant à 3 A. Des informations à ce
sujet sont données dans la section 8 en page 39.
Alternativement, vous pouvez également alimenter la LZV200 par
l'intermédiaire d'un bloc d'alimentation. Ceci est décrit dans la section
6.2 en page 34.
Assurez-vous
que
vous
n'avez
qu'un
seul
type
d'alimentation
connectée.
Donc,
utilisez
SOITun
transformateur, SOIT une alimentation secteur.
6.2 Alimentation en courant
Comme alternative de connexion d'alimentation, vous pouvez utiliser
une alimentation disponible dans le commerce. Le diamètre de la fiche
doit être de 2,5 mm. Les pôles plus et moins n'ont pas besoin d'être
pris en considération. L'alimentation doit fournir au moins 2,5 A et un
maximum de 5A.
Comme tension d'entrée, les valeurs suivantes sont permises :
avec du courant alternatif : min. 14 volts, max. 19 volts ;
avec du courant continu pur : min. 14 volts, max. 24 volts.
Assurez-vous
que
vous
n'avez
qu'un
seul
type
d'alimentation
connectée.
Donc,
utilisez
SOITun
transformateur, SOIT une alimentation secteur.
6.3 Connexion à la voie : bornes J, K
Pour la connexion à la voie, n'utilisez que des câbles de section
suffisante (0,25 mm2 recommandé). Ceux-ci doivent être torsadés. En
cas de lignes étendues, veillez à réalimenter régulièrement la voie en
courant traction par des connexions établies en parallèle.
Figure 2 : Connexion d'une voie à 2 rails.
Figure 3 : Connexion d'une voie à 2 rails +
conducteur central.
Aucun condensateur pour interférence radio ne peut être
installé dans le réseau de voies. Ces condensateurs ne
sont nécessaires que pour le déparasitage radio au cours
de l'exploitation conventionnelle. Cependant, dans le
système Digital plus, ils faussent le format des données et
le transfert impeccable de données est compromis.
Important :
Une exploitation digitale mixte à l'aide des rails et d'une caténaire n'est
pas permise. Dans ce type de situation, si la locomotive se trouvant
sur la voie roule dans la mauvaise direction (cela peut être le cas, par
exemple, après un retournement sur une raquette), le décodeur
embarqué risque d'être détruit par surtension ! Nous recommandons
une exploitation avec prise de courant uniquement par les rails (patins
sur roues), car la sécurité de contact (et par conséquent la
transmission des signaux numériques au décodeur de locomotive) est
beaucoup mieux assurée que par la caténaire.
Si le réseau est divisé en plusieurs circuits alimentés chacun par un
amplificateur individuel, ces circuits doivent avoir impérativement la
même polarité. La borne J d'un amplificateur et la borne J du suivant
doivent donc être raccordées au même côté des voies. S'il en était
autrement, un court-circuit surviendrait lors du franchissement de la
coupure par un train.
Si vous avez créé plusieurs zones d'alimentation sur votre réseau,
vous devez procéder au réglage de la tension sur la voie (tension de
sortie) en veillant à régler la même valeur sur les différents
amplificateurs (voir chapitre 6).
6.4 Connexion à la centrale : bornes C, D, E
L'amplificateur LV103 reçoit le format de données de la centrale
(LZ100, LZV100, LZV200) par les bornes C et D. Les bornes C et D
des différents amplificateurs doivent être reliées entre elles au moyen
d'un câble torsadé.
Si vous reliez en outre la borne E de la centrale à la borne E de
l'amplificateur, celui-ci sera en mesure de communiquer à la centrale
toute surcharge ou tout court-circuit. Dans ce cas, la centrale
déconnectera tous les autres amplificateurs et communiquera
l'information à tous les appareils de commande raccordés au bus
XpressNet.
Le terminal E est également utilisé pour la transmission du détecteur
global Railcom intégré au LZV200.
Figure 4 : Raccordement d'un amplificateur LV103 à la LZV200.
Figure 5 : Raccordement d'un amplificateur LV103 à la LZV100.
7
Réglage de la tension sur la voie
Le LV103 offre la possibilité de régler la limite de tension appliquée à
la voie. Limite de tension veut dire que la tension réglée ne sera pas
dépassée. Cependant, la tension sur la voie peut être effectivement
plus faible que la valeur réglée compte tenu de la puissance du
transformateur d'alimentation et de la tension qu'il délivre.
En fonction de l'échelle de réduction de votre réseau, une modification
de la tension de sortie pour la voie (bornes J et K), telle qu'elle est
réglée en usine, peut se révéler avantageuse. En particulier, pour les
grands écartements, on utilise parfois des tensions un petit peu plus
hautes et, sur les réseaux à l'échelle N, certains préfèrent une plus
faible tension sur la voie. En ce qui concerne la tension délivrée par le
transformateur, elle devrait être ajustée autant que possible en
fonction de la tension souhaitée sur la voie. Si la tension à la sortie du
transformateur est trop haute, cela aura pour seul effet d'engendrer
des déperditions calorifiques indésirables dans l'amplificateur,
lesquelles induiront en retour un déclenchement précoce avant même
que le courant de sortie maximal ne soit atteint.
La tension du LV103 est réglée en usine à 16 V. Ceci étant, vous
pouvez librement choisir une tension comprise entre 11 V et 22 V.
Si vous avez créé plusieurs zones d'alimentation sur votre réseau,
vous devez procéder au réglage de la tension sur la voie (tension de
sortie) en veillant à conférer la même valeur aux différents
amplificateurs mis en service.
Pour régler la tension sur la voie, utilisez la "programmation pendant
l'exploitation", en abrégé "PoM". Mais avant de procéder au réglage de
la tension, familiarisez-vous avec le maniement de la PoM à l'aide de
votre régulateur LH100, LH101 ou LH90.
Pour le réglage de la tension de sortie, le LV103 doit être connecté à
la centrale via les bornes C et D. De plus, la centrale et l'amplificateur
LV103 doivent être branchés.
Procédez comme décrit ci-après :
Sélectionnez sur le régulateur une adresse de locomotive
quelconque (Pas de panique ! Lors du réglage de la tension, si
une locomotive portant l'adresse en question se trouve sur la voie,
ses réglages ne se modifieront pas, car la CV 7 du décodeur de
locomotive ne peut qu'être lue mais en aucune façon modifiée).
Passez en mode "PoM".
Sélectionnez la CV 7.
Programmez la valeur 50 dans la CV 7. Ce faisant, la centrale
passe en mode réglage et sa diode lumineuse indique un double
flash.
Programmez endéans les 15 secondes dans la CV 7 la valeur
pour la tension de sortie souhaitée (voir ci-dessous). La diode
lumineuse s'allume en permanence et la tension sur la voie est
modifiée.
Pour connaître la valeur à programmer dans la CV 7 correspondante à
la tension de sortie (UA), consultez le tableau suivant :
Réglage du courant maximum sur la piste
En usine, la sortie de la LV103 est réglée sur 5 A. Vous pouvez choisir
un réglage compris entre 2,5 A et 5 A.
La "PoM" ("programmation en cours d'exploitation") sert à régler le
débit de sortie. Avant d'effectuer le réglage, vous devez vous
familiariser avec le fonctionnement de la PoM au moyen de votre
régulateur LH100, LH101 ou LH90.
Procédez comme suit :
•
Sélectionnez n'importe quelle adresse de locomotive sur
le régulateur (ne vous inquiétez pas si, pendant le réglage de la sortie,
une locomotive avec l'adresse en question se trouve sur la voie, ses
réglages ne changeront pas parce que la CV 7 du décodeur ne peut
qu'être lue mais pas modifiée.)
•
Passez à la fonctionnalité "PoM".
•
Choisissez la CV 7.
•
Programmez la valeur 50 dans la CV 7. Cela met la LV103 en
mode de programmation et la LED de la LV103 et celle de
l'amplificateur éventuellement connecté LV102/103 émettent un
double flash.
•
Programmez endéans 15 secondes la valeur du courant
souhaitée multipliée par 2 (pour 2,5 A = programmez 5) (voir ci-
dessous) dans la CV 7. La LED brillera constamment à nouveau
et le courant sur la voie sera modifié.
En ce qui concerne quel réglage vous devrez programmer en CV 7
pour une valeur de courant déterminée, voyez le tableau suivant :
Pour utiliser un transformateur de 3 A, veuillez régler un courant
maximum sur la voie de 3 A.
9
RailCom: Activation de l'intervalle de suppression
avec le LV103 :
Note importante: Le réglage d'usine par défaut est activé
RailCom!
Pour
activer
RailCom,
on
utilise
la
PoM,
c'est-à-dire
la
"Programmation pendant la marche". Avant d'entreprendre la
programmation, familiarisez-vous avec la PoM à l'aide de votre
régulateur
LH100,
LH101
ou
LH90.
Pour
activer
RailCom,
l'amplificateur-centrale LZV100/LZV200 doit être branché. La
procédure décrite ci-après permet d'activer l'intervalle de suppression
tant dans l'amplificateur du LZV100 que dans chacun des
amplificateurs LV103 éventuellement raccordés aux bornes CDE du
LZV200/LZV100.
Si vous utilisez une centrale LZV200/LZ100 (avec version de logiciel à
partir de 3.5), vous activez l'intervalle de suppression du ou des
amplificateurs LV103/LV102 raccordés à ses bornes CDE.
Procédez comme suit :
Sélectionnez sur le régulateur une adresse de locomotive
quelconque. N'ayez aucune crainte : s'il s'agit de l'adresse d'une
locomotive présente sur les voies pendant l'activation, les réglages
du décodeur de cette locomotive ne seront pas modifiés car la CV
7 dans le décodeur de locomotive ne peut qu'être lue et non pas
modifiée.
Passez maintenant en mode "PoM".
Sélectionnez la CV 7.
Programmez la valeur 50 dans la CV 7 afin de commuter le
LZV200/LZV100 ou LV103 sur le mode réglage, ce que confirme
un double éclair émis par la DEL de ces appareils.
Programmez dans les 15 secondes qui suivent la valeur 93 pour
activer RailCom dans la CV 7. La DEL brillera de façon constante
indiquant par là que RailCom est activé.
Si vous désirez désactiver RailCom (désactiver l'intervalle de
suppression), procédez comme suit :
Passez en mode "PoM".
Sélectionnez la CV 7.
Programmez la valeur 50 dans la CV 7. Ce faisant, vous commutez
le LZV100 sur le mode réglage, ce que confirme un double éclair
émis par la DEL de ces appareils.
Programmez dans les 15 secondes qui suivent la valeur 92 pour
désactiver RailCom dans la CV 7. La DEL brillera de façon
constante indiquant par là que RailCom est désactivé.
10 La diode indicatrice
Les différents états de fonctionnement du LV103 sont affichés au
moyen d'une diode lumineuse située sur la face frontale.
La diode est
constamment allumée
Tout est ok, l'appareil est en
fonctionnement normal.
La diode clignote
lentement
Bornes C et D non raccordées
ou
Arrêt d'urgence, tension sur la voie coupée
via un appareil de commande
ou
Centrale non en état de fonctionner.
La diode clignote
rapidement
Court-circuit sur le réseau, la tension sur la
voie a été coupée
ou
Surchauffe dans l'amplificateur
ou
Transfo non raccordé à U, V (correct) mais
au contraire à J, K (erroné).
Après le débranchement du LV103, la diode
clignote également vite, ceci est normal.
La diode émet un
double flash
Une programmation avec la PoM vient de
démarrer (voir réglage de la tension sur la
voie).
11 Aide en cas de panne
Erreur
Cause
Solution
Le LV103 n'est pas en état
de fonctionnement (diode
non allumée).
Alimentation interrompue,
fiche du transformateur non
branchée sur le réseau
domestique.
Tester le câblage entre
transformateur et LV103,
brancher la fiche.
La diode clignote
lentement.
Il y a un court-circuit sur le
réseau.
Eliminer le court-circuit.
Il y a une surcharge.
Diviser le réseau en
plusieurs sections et
alimenter celles-ci au
moyen d'ensembles
amplificateur-
transformateur
supplémentaires.
Le LV103 est prête à
fonctionner (la diode est
allumée), mais les
locomotives ne roulent pas,
les aiguillages et les
signaux ne peuvent pas
être commutés.
La liaison entre le LV103 et
la voie et/ou les décodeurs
de commutation est
interrompue (bornes J et K
non raccordées).
Vérifier les liaisons et
corriger le défaut.
Nicht geeignet für Kinder unter 14 Jahren wegen verschluckbarer Kleinteile. Bei
unsachgemäßem Gebrauch besteht Verletzungsgefahr durch funktionsbedingte Kanten
und Spitzen! Nur für trockene Räume. Irrtum sowie Änderung aufgrund des
technischen Fortschrittes, der Produktpflege oder anderer Herstellungsmethoden
bleiben vorbehalten. Jede Haftung für Schäden und Folgeschäden durch nicht
bestimmungsgemäßen Gebrauch, Nichtbeachtung dieser Gebrauchsanweisung,
Betrieb mit nicht für Modellbahnen zugelassenen, umgebauten oder schadhaften
Transformatoren bzw. sonstigen elektrischen Geräten, eigenmächtigen Eingriff,
Gewalteinwirkung, Überhitzung, Feuchtigkeitseinwirkung u.ä. ist ausgeschlossen;
außerdem erlischt der Gewährleistungsanspruch.
Not suitable for children under 14 because of the danger of their swallowing the small
constituent pieces. Improper use can result in injury by functionally necessary points
and edges. For use only in dry areas. We reserve the right to make changes in line with
technical progress, product maintenance or changes in production methods. We accept
no responsibility for errors which may occur for similar reasons. We accept no
responsibility for direct or indirect damage resulting from improper use, non-
observance of instructions, use of transformers or other electrical equipment which is
not authorised for use with model railways, or transformers or other electrical
equipment which has been altered or adapted or which is faulty. Nor can we accept
responsibility when damage results from unsupervised adjustments to equipment or
from acts of violence or from overheating or from the effects of moisture etc..
Furthermore, in all such cases guarantees become invalid.
Les appareils numériques sont non indiqués pour les enfants en dessous de 14 ans en
raison des petites pièces susceptibles d'être avalées. En cas d'utilisation incorrecte
existe un danger de blessures dues à des arêtes vives ! Les appareils sont
uniquement utilisables dans des locaux secs. Sauf erreur due à des modifications sur
base des progrès techniques, de la révision des produits ou d'autres méthodes de
production. Est exclue toute responsabilité pour des dommages et conséquences de
dommages suite à un emploi des produits non conforme à la destination, à un non
respect du mode d'emploi, à une exploitation autre que dans un chemin de fer
miniature, avec des transformateurs de courant modifiés ou détériorés, ou bien d'autres
appareils électriques, à une intervention autoritaire, à une action violente, à une
surchauffe, à une action humide, entre autres choses. De surcroît est éteinte toute
prétention à l'exécution de la garantie.Est exclue en outre toute responsabilité pour les
conséquences d'erreurs qui seraient commises par suite d'une mauvaise interprétation
ou d'un mauvais usage de la présente traduction du fascicule en français. De même,
est exclue toute responsabilité des conséquences d'une erreur éventuelle de traduction
ou de toute erreur d'interprétation qui aurait échappé à la vigilance du traducteur.Sous
réserve de modifications, d'erreurs et de possibilités de livraison.
Lenz Elektronik GmbH
Vogelsang 14
35398 Giessen
Fon: 06403 900 133
Fax: 06403 900 155
www.lenz-elektronik.de
[email protected]
Diese Betriebsanleitung bitte für späteren Gebrauch
aufbewahren!
Keep this operation manual for future reference!
Ce mode d'emploi est à conserver pour une
utilisation ultérieure !