Pro-Elec PEL00930 Quick Start Manual
Read Online
Read the Pro-Elec PEL00930 Quick Start Manual online using the built-in PDF viewer.
Text of the manual
Models: PEL00930, PEL00931,PEL00932
& PEL00933
Please read these instructions carefully before use and retain for future
reference.
This floodlights must be installed by a qualified electrician in accordance with current
building and IET wiring regulations (BS7671).
IMPORTANT SAFETY INFORMATION
•
Do not use PVC cable to connect this floodlight to your wiring supply. Rubberised
cable (type H05RN-F), with three conductors of at least 1.0mm² cross-sectional
area must be used. This product must be connected to Earth.
•
The front of this floodlight is made of tempered glass, replace if cracked.
•
LED lamps are extremely bright. To avoid possible damage to the eyes, do not
stare into an LED beam.
•
In use, avoid touching any external surface of the floodlight, due to the possibility
of high temperatures.
•
Do not use near flammable materials.
•
The floodlight must be positioned so that there is at least 1m between the front of
the work light and the surface to be illuminated.
•
The floodlight has an IP rating of IP65.
•
It is suitable for use in an ambient temperature between -30°C and +45°C.
The floodlight has a beam angle of 120°. It can be tilted upwards and downwards at an
angle of approximately 90°. The angle of adjustment will vary slightly between models.
INSTALLATION
The floodlight is suitable for connection to a 220-240V, 50Hz earthed supply. It is
designed for permanent connection to fixed wiring, which must be a suitable circuit
protected by an RCD with an operating current not exceeding 30mA and an MCB or
fuse of the correct rating.
Mounting the Floodlight
•
Before commencing installation, check that you have all of the tools you need.
•
Check that the floodlight is not damaged. If there is any damage, return it to the
place of purchase. Do not attempt to repair it yourself.
•
Choose your location to fix the floodlight, taking into account the guidance above.
•
Use the floodlight bracket to mark the position of the fixing holes.
•
Drill the fixing holes and fix the floodlight into position using appropriate size
screws and wall plugs (not provided). Check that it is securely fixed.
•
This floodlight is suitable for outdoor lighting applications, for domestic use only.
•
Do not use in areas where an explosive or chemical atmosphere may exist. Do not
use in areas where ventilation is restricted.
•
It is suitable for mounting on plasterboard, wood or masonry surfaces. Highly
flammable surfaces such as plastic or polystyrene must not be used.
•
Do not install on damp or conductive surfaces such as metal. It should be placed
away from any flammable materials.
•
Before drilling any fixing holes, check that there are no hidden obstructions behind
the mounting surface such as pipes or cables.
•
The recommended height for installation of the floodlight is between 0.5 and 3
metres.
•
Ensure that there is space around the floodlight to allow adequate circulation of air.
•
Orientation of the floodlight is important as shown below:
POSITIONING
Wiring the Floodlight
•
Ensure that the mains supply is isolated before commencing installation.
•
A suitable rated connector must be used to connect the lead from the floodlight to
the mains supply.
•
Connect the mains cable to the connector. Ensure that the correct polarities for
Live, Neutral and Earth are observed i.e.
- Green/yellow - Earth terminal
- Brown - Live terminal
- Blue - Neutral terminal
•
After wiring, check that there are no stray strands and that all the wires have been
correctly installed.
•
Before connecting power, perform the electrical tests specified in the current
Building and IET Wiring Regulation to ensure that the installation is safe and that
the wiring has been performed correctly.
•
Restore the mains power supply and check that the floodlight illuminates the
required area. Tighten the floodlight using the bolts on the brackets.
SPECIFICATION
CLEANING & MAINTENANCE
•
Clean the floodlight only with a soft dry cloth. Do not use any chemicals, abrasives
or solvents that could damage the floodlight.
•
The floodlight has a sealed LED lamp and is maintenance free. The LED lamp
cannot be replaced. When the LED lamp reaches the end of its life, the floodlight
will have to be replaced.
PEL00930
PEL00931
PEL00932
PEL00933
Input Voltage
220-240V AC
50/60Hz
220-240V AC
50/60Hz
220-240V AC
50/60Hz
220-240V AC
50/60Hz
Nominal luminous flux
700lm
1400lm
2100lm
3500lm
Wattage
10W
20W
30W
50W
Beam angle
120°
120°
120°
120°
Dimmable
No
No
No
No
Nominal lifetime of the lamp
20,000h
20,000h
20,000h
20,000h
Light source
SMD2385
SMD2385
SMD2385
SMD2385
Colour temperature
6000K
6000K
6000K
6000K
Colour rendering (CRI Ra)
≥80
≥80
≥80
≥80
Warm up time
(60% full light)
Instant full
light
Instant full
light
Instant full
light
Instant full
light
Ingress rating
IP65
IP65
IP65
IP65
Earthing
Class I
Class I
Class I
Class I
Weight
0.225kg
0.340kg
0.522kg
0.608kg
Dimensions WxHxD (mm)
105 x 77 x 28
134 x 98 x 34
173 x 126 x 37
173 x 126 x 46
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical & Electronic
Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste,
but kept separate for the treatment, recovery and recycling of the materials used. Contact your local
authority for details of recycling schemes in your area.
Made in China
PO Box 13362 Dublin 2
PR2 9PP
Man Rev 1.4