Important: Please Read Before Installation
Important Safety Instructions
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situation.
1. Make sure that the power is turned OFF before installing or servicing
this luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL Listed wire connectors that
is suitable for outdoor use.
5. Position the low voltage wire and UL listed wire connector so that
it is located within 6 inches (15.2 cm) from a building structure, a
luminaire or fitting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable is required, please contact
www.voltlighting.com or call 1-813-978-3700.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS.
1. Lamp gets HOT quickly!
2. Do not touch the hot lens, guard or enclosure.
3. Keep lamp away from materials that may burn.
4. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
5. Do not operate the luminaire fitting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
!
!
Parts Required (sold separately)
A. (1) PAR36 Bulb
B. (1) Mounting Accessory
[email protected] • 813.978.3700
- 3 -
Product Dimensions
2.3”
4.65”
4.25”
Remove Glare Guard
1
A. (1) Fixture
Rotate the glare guard
counter clockwise and remove
it from the fixture. Then
remove the bulb holder.
ROTATE
Fixture
Bulb Holder
Glare Guard
w w w . v o l t l i g h t i n g . c o m
INSTALLATION INSTRUCTIONS
- 4 -
2
VOLT® G2 Big Par36 Cast Brass Flood Light
VFL-4501-4-BBZ
3
Install PAR36 Bulb
Fixture
Supply Wire
PAR36 Bulb
Screw
Use a PAR36 bulb (sold separately),
with the correct wattage and type
as marked on luminaire label.
Connect the supply wires using the
screws on the bottom of the PAR36
bulb, tighten with a screwdriver.
CAUTION: Do not exceed maximum
wattage marked on luminaire
label.
NOTE: DO NOT touch lamp with
bare hands. Use soft cloth to
handle lamp.
Install Bulb Holder and Glare Guard
Glare Guard
Tuck the excess wires inside
of the fixture and place the
PAR36 bulb inside. Place the
bulb holder onto the top of
the PAR36 bulb and thread
the glare guard onto the
fixture.
Fixture
Bulb Holder
PAR36 Bulb
[email protected] • 813.978.3700
- 5 -
4
5
Install Stake
Board
Ground
Soil
Stake
Determine the desired location
for mounting the stake. Hammer
the stake into the ground until
flange of stake is flush to grade.
To avoid damage to the stake,
place a board on top of the stake
while hammering.
Note: If the ground is hard and
the stake is difficult to install,
make a crosscut in the ground
using a flat shovel.
Install Fixture to Stake
Fixture
Wireway Slot
Ground
Soil
Stake
Cable
Clear away an area in the
ground at the wireway slot on
the top of the stake. Place the
fixture wire into the wireway
slot and thread the fixture onto
the stake. Hand tighten until
snug.
w w w . v o l t l i g h t i n g . c o m
- 6 -
7
VOLT® G2 Big Par36 Cast Brass Flood Light
VFL-4501-4-BBZ
6
Wire Connection
Pigtail
Main Supply Cable
Wire Connectors
Main Supply Cable
Strip both leads from the fixture pigtail. Using two UL listed wire
connectors (sold separately), connect the leads from the fixture to the
main supply cable leads.
Fixture
Supply Wire
Adjust Fixture
Fixture
Screw
ROTATE
Loosen the knuckle and adjust the
fixture to the desired orientation.
Tighten the knuckle after you find
the desired orientation.
[email protected] • 813.978.3700
- 7 -
Install/Replace PAR36 Bulb
Reverse Step 1 - Step 3 to expose the PAR36 bulb and replace it with correct
wattage and type marked on luminaire label. Reinstall glare guard.
IMPORTANT: Halogen lamps must be protected from moisture and dust
at all times. Always reinstall glare guard when removed.
Specifications and product details subject to change without notice.
© Copyright 2020, VOLT® Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3700
w w w . v o l t l i g h t i n g . c o m
Help Hotline:
1-813-978-3700 • Mon-Fri 8am-8pm • Sat-Sun 10am - 6pm (EST)
- 8 -