Professional Lighting Genius s.r.l - Ex Strada Statale 96, NC - 70020 Toritto (Ba) - Phone: (+39) 080 603244 - [email protected] - www.plgenius.com

EDGE MANUALE D’USO USER MANUAL ATTENZIONE | WARNING Sovratensioni provenienti dalla rete elettrica di alimentazione dell’impianto/apparecchi o di origine elettrostatica (ESD) provenienti dall’ambiente , possono danneggiare in maniera irreversibile gli apparecchi a LED. Si consiglia quindi l’installazione di un dispositivo di protezione dalle sovratensioni sull’impianto elettrico che attenua l’intensità di questi fenomeni Overvoltages from the power supply of the system / devices or of electrostatic origin (ESD) from the environment, can irreversibly damage the LED luminaires. It is therefore advisable to install a protective device against overvoltages on the electrical system which attenuates the intensity of these phenomena • • • Tenere lontano da sostanze chimiche aggressive Keep away from aggressive agents • Il sistema di connessione deve avere un grado di protezione IP uguale o superiore al grado di protezione IP del prodotto • The connection system must be equal to or greater than the IP rating of the spotlights. • • Prima di procedere alla installazione o alla manutenzione del presente dispositivo è necessario disattivare sempre l’energia elettrica; • Before proceeding with the installation or maintenance of this device, you must always turn off the electricity; La ditta Professional Lighting Genius declina ogni responsabilità per danni causati da un proprio prodotto montato in modo non conforme alle istruzioni. • The company Professional Lighting Genius assumes no responsability for damages caused by its own product installed not in accordance to instructions. • La ditta Professional Lighting Genius declina ogni responsabilità qualora l’installazione non avvenga secondo le norme vigenti; • The company Professional Lighting Genius disclaims any liability if the installation is not done according to applicable regulations; • In nessun caso l’apparecchio deve essere ricoperto da materiali termoisolanti o simili; • Under no circumstance must this product be covered • Modifi che o manomissioni del prodotto possono rendere l’apparecchio pericoloso e annullano ogni condizione di garanzia; • Modifi cations or tampering of the product can make the device dangerous and will invalidate any warranty condition; • Tutte le operazioni di installazione o di manutenzione devono essere eff ettuate da personale tecnico specializzato; • All installation or maintenance must be performed by qualifi ed personnel; • • L’impianto va alimentato solo dopo il collegamento; The plant should be operated only after connecting; • Leggere e conservare le seguenti istruzioni Read and store following instructions ATTENZIONE Per evitare infi ltrazioni di acqua e la formazione di condensa utilizzare giunti preriempiti in gel, nastro autoagglomerante o giunto circolare di connessione IP68 ( CONET1 ) nell’ eff ettuare il collegamento. WARNING To avoid water infi ltrations, carry out the connection with pre-fi lled gel joints, self amalgamating scotch or IP68 circular joint connector ( CONET1 ) CONET1 Giunto circolare di connessione IP68 ( venduto separatamente ) CONET1 IP68 circular joint connector ( sold separately ) Giunto preriempito in gel ( venduto separatamente ) Pre-fi lled gel joints ( sold separately ) 30’ min. 30’ min. PERIODO DI ACCENSIONE GIORNALIERO AMMESSO / ALLOWED DAILY OPERATION PERIOD

Professional Lighting Genius s.r.l - Ex Strada Statale 96, NC - 70020 Toritto (Ba) - Phone: (+39) 080 603244 - [email protected] - www.plgenius.com

DATI TECNICI | TECHNICAL DATA EDGE MANUALE D’USO USER MANUAL POTENZA MASSIMA / POWER MAX : 12W - 220V / 240V 1 power LED multichip NUMERO DI LED / LED QUANTITY : 70 - 80 - 90 - >90 INDICE RESA CROMATICA / CRI : Asymmetric , Diffused OTTICHE DISPONIBILI AVAILABLE OPTICS : -20°C +40°C TEMPERATURA DI UTILIZZO WORKING TEMPERATURE : Appliques FISSAGGIO / FIXING : I CLASSE / CLASS : IP65 GRADO DI PROTEZIONE IP / IP RATE : Incluso / Included ALIMENTATORE / DRIVER : COLORE DEL LED (K) LED COLOUR (K) : 4000° - 3000° - 3000° CRI90 - 2700° DIMENSIONI | DIMENSIONS 1000 750 500 200 Ø90 100 170 100 170 100 170 170 100 Ø90 Ø90 Ø90 100 200 500 750 1000 170 170 170 100 100 100 Ø90 Ø90 Ø90 Ø90 CONNESSIONI | CONNECTIONS 220V / 240V Schema di collegamento diretto alla rete elettrica Direct connection diagram to elettric network 1 Realizzare il cablaggio in assenza di tensione di rete. Make the wiring in complete absence of line voltage. 2 Collegare l’apparecchio alla rete. Connect the device to the electric network. 3 Porre la rete sotto tensione. Energize the network. MATERIALE E FINITURA MATERIAL AND FINISH : Corpo e base in acciaio Inox AISI 316L verniciato, testa in alluminio anodizzato e verniciato Body and fi xing base in painted inox steel AISI 316L ,head in anodized and painted aluminium Verde Marmo, Corten, Grigio, Nero, altri RAL su richiesta Marble Green, Corten, Grey, Black, other RAL on request

Professional Lighting Genius s.r.l - Ex Strada Statale 96, NC - 70020 Toritto (Ba) - Phone: (+39) 080 603244 - [email protected] - www.plgenius.com

ISTRUZIONI DI MONTAGGIO | ASSEMBLY INSTRUCTIONS EDGE MANUALE D’USO USER MANUAL Eseguire il cablaggio elettrico avendo cura di sigillare i cavi con mezzi adeguati a garantire una tenuta IP65 Fissare il corpo del dispositivo alla base precedentemente bloccata, avvitando le viti in dotazione Rimuovere le tre viti di supporto laterali ed estrarre la base di fi ssaggio Bloccare la base di fi ssaggio nella posizione prescelta utilizzando l’idonea tassellatura ( inclusa ) Make the electrical wiring taking care to seal the cables with devices suitable for an IP65 rating protection. Fix the the device to the previously locked base by screwing the supplied screws Remove the three lateral screws and remove the fi xing base Fix the base in the selected position using an approprate device ( included ) 3 4 1 2 2 4 1 3 Do not cover the device Never connect or disconnect the fi xture when the netework is energized. Non coprire l’apparecchio. Non collegare o scollegare l’apparecchio con la rete sotto tensione. ATTENZIONE - WARNING ATTENZIONE - WARNING