The image is shown on the computer screen.

NOTE You must accept the image in the Planmeca Romexis program. 6. Press the release lever on the left ear post holder and very carefully slide the positioning cones out of the patient’s ears. 7. Guide the patient away from the cephalostat. 5 Cephalometric exposure 36 Planmeca ProMax User's manual ...

Select the radiation symbol or the forward button.

Green lights flash on the touch screen and exposure button when the X- ray system is getting ready for an exposure. The green lights stop flashing and stay on continuously when the X-ray system is ready for an exposure. 2. Ask the patient to stay as still as possible. 3. Move to a protected area. 5 Cephalometric exposure 34 Planmeca ProMax User's manual ...

Large adult (L)

68 10 Extra large adult (XL) 70 10 Factory presets for program types Posteroanterior and Anteroposterior PATIENT SIZE kV VALUE mA VALUE Child (XS) 76 11 Small adult (S) 78 11 Medium-sized adult (M) 80 11 Large adult (L) 82 11 Extra large adult (XL) 84 11 Factory presets for program type Hand PATIENT SIZE kV VALUE mA VALUE All patient sizes (XS, S, M, L & XL) 60 4 If you need to adjust the preset exposure values for the current exposure: 1. Select the kV / mA field. 2. Use the minus or plus buttons to set the exposure values you wish to use. To imp ...

4.1.2 Removing 2D or 3D patient supports

If the temple supports are in place, turn them down and remove all patient supports from the patient support table. If the support bars are in place, remove all patient supports from the patient support table, including support bars, chin cup and adapter. • To remove the support bars, first loosen the locking knobs and then pull the support bars out. 4 Preparations for exposure User's manual Planmeca ProMax 9 ...

Carefully pull the sensor out.

CAUTION Do not drop the sensor. Planmeca limited warranty does not cover damage which is due to misuse, e.g. dropping the sensor, neglect, or any cause other than ordinary use. Do not use the sensor if the shock indicator (marked in the figure) is red - contact your service technician for help. If you have any reason to believe that the sensor might be faulty, take a test exposure before taking a patient exposure. 4 Preparations for exposure 12 Planmeca ProMax User's manual ...

5.3 Patient positioning in lateral projection

1. Rotate the head support plate: 1. To the 0° position if you want the patient to face away from the wall. OR 2. To the 180° position if you want the patient to face towards the wall. The corresponding program is automatically selected and the illustration on the screen shows that projection. 5 Cephalometric exposure 18 Planmeca ProMax User's manual ...

Planmeca ProMax user guide recommended for: FIT CAD System, INTRA X-RAY UNIT, Proline EC Panoramic, Sovereign Classic, Planmeca ProMax 3D s.

⚠️ Download Safety

The Medical Equipment Operation & user’s manual (42 pages) is completely safe to download (last scan date: 17/12/2025).

Related PDF Instructions for Planmeca ProMax:

Medical Equipment Equipment: Frequently Requested

Have some Questions about Planmeca ProMax Device?

Get valuable and actionable advices from other Planmeca ProMax device users. Describe your problem or question, regarding the using of ProMax, in as much detail as possible, and other users will be able to answer you.