Vicon CAPSULE Quick Start Manual

Specifications

Brand: Vicon
Category: Security Camera
Model: CAPSULE (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 4

Read Online

Read the Vicon CAPSULE Quick Start Manual online using the built-in PDF viewer.

Text of the manual

C A P S U L E

Quick Start Guide Vicon Capsule Quick Start Guide, Revision 2.0 For use with Vicon Vantage and Vicon ViperX cameras. © Copyright 2019–2021 Vicon Motion Systems Limited. All rights reserved. Vicon Motion Systems Limited reserves the right to make changes to information or specifications in this document without notice. Vicon® is a registered trademark of Oxford Metrics plc. Vicon Capsule™, Vicon Vantage™, and Vicon ViperX are trademarks of Oxford Metrics plc. Other product and company names herein may be the trademarks of their respective owners. Vicon Motion Systems is an Oxford Metrics plc company.

B E Y O N D M O T I O N

Page 2 Vicon Capsule 2 • • Introducing Vicon Capsule Capsule provides protection for all Vicon Vantage and ViperX cameras that are installed in outdoor or exposed environments. In particular, it prevents the performance of the cameras from being affected by dust and moisture. External seal Ethernet cable with ferrite Front of Capsule (rear & front casing) Thermal Interface Material (TIM) Lens cover Curved surface for TIM Vicon Vantage or ViperX camera Camera-mounting screws O-ring x 2 Internal Ethernet port Specification and standards Independently tested and certified to confirm: Operation between -5°C–35°C, 10%–98% RH Weatherproof IP65-rated enclosure (see info box, right): dust-tight and protected against both water splashes, such as rain, and water projected from a nozzle IP65-rated indicates that Capsule is suitable for general outdoor use. It may not meet the requirements for IP66 (resistance to high pressure water jets) or IP67 (submersion in 1.5 meters of water for 30 minutes). Conversely, equipment rated IP66 or IP67 does not necessarily achieve IP65 protection.

B E Y O N D M O T I O N

Vicon Capsule 2 Page 3 Prepare a Vicon Capsule 1. Open the Capsule by unfastening the two latches on the sides. 2. Ensure that the two O-rings are in place in the two grooves around the edge of the back plate. If you have to fit the O- rings, push one O-ring into the first (slightly smaller) groove, and then push the other one past the first, into the second groove. 3. Peel the clear plastic coating from the gray side of the Thermal Interface Material (TIM) and carefully stick the TIM to the curved surface on the inside of the back plate. 4. Connect the ferrite end of the Ethernet cable to the port on the inside of the back plate. Install the camera 1. If a lens cover is required, fit it over the lens on the front of the camera by pressing until it clicks into place. 2. Connect the free end of the Ethernet cable to the camera, then place the camera onto the back plate. 3. Secure the camera to the back plate with the two screws supplied and tighten them. Important: Ensure the camera is square (parallel) with the back plate. 4. Place the front of the Capsule over the back, enclosing the camera that is attached to the back plate. 5. Fasten the latches and press the front and back sections of the Capsule together so that the seal is airtight. 6. Stretch the seal around the edge of the front window of the Capsule. First,  push each of the four corners of the seal into the gap between the window and the housing. Next, starting with the center of each edge, firmly press the rest of the seal into the gap. To ensure the IP rating is maintained, check that the tightly fitting seal appears compressed around all the edges . Important: If you're using a lens cover, ensure that it is fully in contact with the window at the front of the Capsule. Tip: To fit a different camera variant into the Capsule, change the position of the window by clipping it to the appropriate slot inside the housing. 

B E Y O N D M O T I O N

Page 4 Vicon Capsule 2 Seal the cable connection Important: To ensure the seal integrity, use only the RJ45 cable that is provided with the Capsule unit. 1. Ensure you have the required parts of the waterproof cable cover and the RJ45 cable. For non-moulded cables only: To ensure a tight seal, add the supplied support between the housing (far left) and the split seal. 2. Slip the back sealing nut and the split seal onto the cable. 3. Push the cable as far as it will go into the front of the cover, so that the front of the plug slightly protrudes beyond the opening. 4. Firmly push the seal fully into the front of the cover. 5. Twist the back sealing nut onto the thread on the front of the cover. 6. Remove the protective cap from the connection on the back of the Capsule, then attach the RJ45 cable by twisting the front of the cover until it clicks, which indicates that the connection is fully sealed. 7. After the back sealing nut is screwed on tightly, ensure the RJ45 plug protrudes far enough. Before installation, test the connection by moving the cable in multiple directions at ground level to ensure a good connection is maintained. Mount the cameras Do not mount the assembled unit from a ladder. Instead use a Mobile Elevating Work Platform (MEWP) or Aerial Work Platform (AWP), such as a cherry picker. Before using the camera, remember to remove the protective film from the window on the front of the Capsule. Re-use Capsules You may remove cameras from their Capsules and replace them as many times as required. Important: To ensure the integrity of the seal and that the enclosure continues to meet IP65 standards, ensure that O-rings and all other parts, including TIMs, are in good condition before use, and that installation is completed in accordance with this guide. Use Capsules in sunlight If using cameras enclosed in Capsules in strong sunlight, high temperatures or poor airflow, to prevent overheating, you may want to shade the Capsules or provide additional cooling. Contact Vicon Denver, CO Vicon Denver 7388 S. Revere Parkway Suite 901, Centennial CO 80112, USA T: 303.799.8686 F: 303.799.8690 E: [email protected] Los Angeles, CA Vicon LA 3750 S. Robertson Boulevard Suite 100, Culver City, Los Angeles CA 90232, USA T: 310.437.4499 E: [email protected] Oxford, UK Vicon Oxford Unit 6, Oxford Industrial Park Mead Rd, Yarnton, Oxford OX5 1QU, United Kingdom T: +44.1865.261800 E: [email protected] Vicon trademarks Vicon Capsule test certificates are available on the Vicon website: https://docs.vicon.com/display/HD/Vicon+Capsule+certification Warning: The assembled unit is heavy, so if it is mounted where the camera may fall and injure people or equipment, tether it to its mount with a safety bond.  Warning: As the rear panel can have elevated temperatures, avoid touching it during and after operation. 

Other Security Camera Manuals