Ei Electronics Ei 204EN Instructions Manual

Brand: Ei Electronics
Category: Smoke Alarm
Model: Ei 204EN (Instructions Manual)
File Type: PDF
File Size: 0.19 Mb
Pages: 32
Text of Ei Electronics Ei 204EN Instructions Manual

Ei Electronics Ei 204EN Model Ei 204EN

Model Ei 205EN Model Ei 205ENA Model Ei 205CEN - STANDARD - WITH MEMORY - WITH MEMORY & SEALED IN BATTERIES - WITH MEMORY & INTERCONNECT Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation. The leaflet should be regarded as part of the product. If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to be given to any sub

READ THIS FIRST

WHAT TO DO WHEN THE CO ALARM SOUNDS CARBON MONOXIDE - THE SILENT KILLER! WHERE TO PLACE CARBON MONOXIDE ALARMS INSTALLATION TESTING & MONITORING YOUR CO ALARM MAINTAINANCE LIMITATIONS OF CARBON MONOXIDE ALARMS HOW TO PROTECT YOUR FAMILY TECHNICAL SPECIFICATIONS GETTING YOUR CARBON MONOXIDE ALARMS SERVICED GUARANTEES TROUBLESHOOTING Page CONTENTS 2 B15583/R0/204EN&205EN/U&C 8

Ei Electronics Ei 204EN 1. READ THIS FIRST

Power up the unit by smoothly withdrawing the red “pull” tab at the top left hand corner of the unit. If the batteries are supplied separately install the three AA batteries by sliding the upper cover off as shown in figure 5a page 15.The green, red & amber lights will immediately flash in sequence to show they are working - this is normal. Install the Carbon Monoxide Alarm (CO Alarm) in every room that contains a fuel burning applia

Ei Electronics Ei 204EN When the CO Alarm detects abnormal levels of CO (above 50ppm CO) the red

light starts to flash immediately and the horn will sound within 90 minutes. At higher levels of CO the alarm will turn on sooner (see table B - page 8). The CO Alarm will automatically reset once the CO has cleared. Pressing the test/hush button resets the CO Alarm immediately (below 300ppm CO). If CO is still present the red light and horn will turn on again after about 4 minutes. T

Ei Electronics Ei 204EN (5) Ring your gas or other fuel supplier on their emergency number. Keep the

number in a prominent place. (6) Do not re-enter the property until the alarm has stopped. (If the alarm has been silenced by pressing the test/hush button, wait at least 5 minutes so the alarm can check that the CO has cleared). (7) Do not use the fuel appliances again until they have been checked by an expert. In the case of gas appliances this must be a CORGI registered install

High levels of CO in a house can be caused by:

• Incorrectly or poorly installed fuel-burning appliances. • Blocked or cracked chimneys/flues. • Blocked vents or draught-proofing which makes areas with fuel burning appliances or fireplaces airtight. • Engines of cars, lawnmowers etc. left running in confined spaces. • Portable paraffin or gas heaters in badly ventilated rooms. 3.2 Symptoms of Carbon Monoxide Poisoning Most people know that high l

Many cases of reported Carbon Monoxide poisoning indicate that while victims are

aware they are not well, they become so disorientated that they are unable to save themselves by either leaving the building or calling for assistance. Young children and household pets may be the first affected. Table A: Effects of Carbon Monoxide Poisoning 35 The maximum allowable concentration for continuous exposure in any 8 hour period according to OSHA *. 150 Slight

3.3 What happens when your CO Alarm detects Carbon Monoxide ?

When the Alarm detects potentally dangerous levels of CO, it flashes the red alarm light immediately and then sounds a loud alarm if the CO persists.Table B below shows how the CO Alarm reacts to different levels of CO gas and exposure time. At higher levels of CO the alarm turns on sooner. The rate of flashing of the red light indicates the level of CO. Table B: CO Alarm Response * unless it ha

NEVER IGNORE THE ALARM.

Pre-Alarm: When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps locate CO leaks as the unit gives an indication straight away. (Without this feature the CO level would need to be at 50ppm CO for 90 minutes for an indication to be given). Note the Pre-Alarm signal may be triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a concern

Reset Memory by holding down the test button for over 20 seconds until the red light

stops flashing. Cover the horn with a cloth to muffle the alarm during this time. Please note that the memory will also be reset when the unit is unpowered. 4. WHERE TO PLACE CO ALARMS 4.1 Ideally a Carbon Monoxide Alarm should be installed in: - Every room containing a fuel burning appliance, and - Remote rooms where occupants spend a considerable amount of time - Every b

4.2 Unsuitable Locations

Do not place the CO Alarm in any of the following areas. (1) In the immediate vicinity of a cooking appliance (keep it at least 1 metre horizontally from it). (2) Outside the building. (3) In an enclosed space (e.g. in or below a cupboard). (4) In a damp or humid area. (5) Directly above a sink or cooker. (6) Next to a door, window, air vent or anywhere that it would be affected by draughts. (7) Next to an extractor fan. (8) Where

Ei Electronics Smoke Alarm Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Ei100L

Ei100L (Smoke Alarm ePDF Manual, #YV52WH)

2 0.11 Mb 573 109 09-10-2026
Ei3105TYCH

Ei Electronics Ei3105TYCH User Manual (Product manual), @4YF18Z

2 0.12 Mb 1143 229 30-08-2026
Ei156TLH

Ei Electronics Ei156TLH Guide (User instructions), @5676WY

3 0.25 Mb 581 134 06-07-2026
Ei151TLR

#46B1S2: Ei151TLR Smoke Alarm Product manual

2 0.11 Mb 227 57 20-07-2026
Ei161

Ei Electronics Ei161 User Manual (Installation instructions), @7I1O6L

4 746 187 30-08-2026
Ei605MTYRF

Smoke Alarm #RM98PY

12 1.19 Mb 245 52 11-05-2026
Ei141RC - Ionisation

Ei Electronics Ei141RC - Ionisation User Manual (User instructions), @51NLQH

14 1423 228 17-04-2026
EiA605MRF

Guide: Ei Electronics EiA605MRF (7OA47F, Upd.17-09-2026)

12 785 118 17-09-2026
Ei127

User Manual: Ei Electronics Ei127 (ND42M2, Upd.16-05-2026)

2 925 232 16-05-2026

Smoke Alarm: Similar Manuals