Ei Electronics Ei 225E User Instructions

Brand: Ei Electronics
Category: Smoke Alarm
Model: Ei 225E (User Instructions)
File Type: PDF
File Size: 0.14 Mb
Pages: 6
Text of Ei Electronics Ei 225E User Instructions

Ei Electronics Ei 225E Open unit by sliding cover up as shown in figure 1. Then

remove the terminal block cover screw. What to do when the Alarm sounds: (1) Open the doors and windows to ventilate. (2) Turn off the appliance where possible and stop using the appliance. (The alarm can be silenced immediately by pushing the test/hush button if the level is below 150ppm CO). (3) Evacuate the property leaving the doors and windows open. (4) Telephone your gas or other fuel supplier

Table B shows how the built in microprocessor reacts to differ-

ent levels of CO gas and exposure time. At higher levels of CO the alarm turns on sooner. The rate of flashing of the red light indicates the level of CO. If your CO Alarm sounds follow the instructions on page 2. When ventilation is provided by leaving the windows and doors open, the CO build up may have dissipated by the time help ar- rives and the alarm may have stopped sounding. Although y

Ei Electronics Ei 225E - the alarm should be located at a level similar to the breathing

zone of the occupant (typically in the living rooms at 1.5 to 2.0m above floor level and in bedrooms at the height of the bed). The BS 7860 : 1996 standard recommends that the CO Alarm should be at least 1.5 metres (5 ft) above floor level. (see fig.3A) and also the detector should be at least 1.85 metres (6 ft) from the appliance. Warnings: (1) The CO alarm should be installed by a qualifie

How to distinguish between CO Alarm and Smoke

Alarm warnings The CO Alarm has a distinctive on-off sound of 3 pulses, fol- lowed by a pause as compared with a typical Smoke Alarm which has a rapid pulsing sound. In addition, when your CO Alarm is sounding the red alarm light in the centre of the cover will be flashing. Testing both your CO Alarms and Smoke Alarms weekly will help you and your family to clearly distinguish between them in an emergency. Clea

(10) Install CO Alarms in all areas recommended in this leaflet.

(11) Recognise that CO poisoning may be the cause when fam- ily members suffer from “flu-like” symptoms when at home but feel better when they are away for extended periods. Operating Voltage : 230±10% V~, 50Hz Power : 1 Watt (50mA) Power on Indicator : Green light on. Sensor : Electrochemical CO Sensor (Filter on sensor enhances selectivity) CO Sensitivity : Meets or exceeds the CO sens

Read and retain carefully for as long as the product is being used. It contains

vital information on the operation and installation. The leaflet should be re- garded as part of the product. If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to be given to any subsequent user. TEST & HUSH BS7860 : 1996 MODEL: Ei225E CARBON MONOXIDE ALARM ALARM FAULT MAINS POWER MODEL Ei 225E WARNINGS The Alarm s

Ei Electronics Smoke Alarm Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Ei166R

Guide: Ei Electronics Ei166R (8D4775, Upd.27-06-2026)

2 0.08 Mb 48 8 27-06-2026
EiA605MRF

Ei Electronics EiA605MRF User Manual (Instructions manual), @3ETL55

12 142 33 26-07-2026
Ei161RC

Ei Electronics Ei161RC Guide (Installation instructions manual), @M3V8G1

16 0.6 Mb 223 38 27-06-2026
Ei2110e Series

PDF User Manual (@8XPMRP), Ei Electronics Ei2110e Series Smoke Alarm (02-10-2026)

40 482 107 02-10-2026
Ei166R

Smoke Alarm #D38NTG

2 1482 371 09-08-2026
Ei175 Ionisation

Smoke Alarm #36235D

2 0.2 Mb 697 126 27-09-2026
Ei3105TYCH

User Manual: Ei Electronics Ei3105TYCH (4998PH, Upd.25-08-2026)

2 0.12 Mb 1197 240 25-08-2026
Ei156TLH

#29U4RN: Ei156TLH Smoke Alarm Product manual

2 0.1 Mb 1246 237 21-09-2026

Smoke Alarm: Similar Manuals