Read and retain carefully for as long as the product is being used. Contains vital information on the

operation and installation. This leaflet should be regarded as part of the product. If you are just installing the unit, this leaflet must be given to the householder. This leaflet is to be given to any subsequent user. The RadioLINK Carbon Monoxide Alarm Ei262 will communicate with all other RadioLINK devices including Smoke/Heat/Fire Alarms,

What to do when you alarm is activated

CARBON MONOXIDE - THE SILENT KILLER ALARM POSITIONING INSTALLATION 4.1 Mounting & Wiring Alarms 4.2 RadioLINK Interconnecting etc. 4.3 Hardwired Interconnect USING & TESTING YOUR SYSTEM HOW TO DISTINGUISH BETWEEN CO ALARM & SMOKE ALARM WARNINGS MAINTENANCE LIMITATIONS OF CO ALARMS HOW TO PROTECT YOUR FAMILY GETTING YOUR CO ALARM SERVICED FIVE YEAR GUARANTEE TECHNI

1. IMPORTANT INFORMATION

WARNING: The Alarm should be permanently wired to the mains by a qualified electrician in accordance with IEE wiring regulations (BS7671). Install a Carbon Monoxide (CO) Alarm in every room that contains a fuel burning appliance, and in rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting rooms. In rooms with an fuel burning appliance, install (preferably) on the ceiling (300mm from walls and between 1m to 3m

Ei Electronics Ei262 WHAT TO DO WHEN THE CARBON MONOXIDE ALARM IS ACTIVATED:

(1) Open the doors and windows to ventilate the area. (2) Turn off all fuel appliances where possible. (The alarm can be silenced immediately, with low levels of CO, by pushing the Test/Hush button). (3) Evacuate the property leaving the doors and windows open. (4) Get medical help immediately for anyone suffering the effects of Carbon Monoxide poisoning (headache, nausea), and advise that Carbon Mono

2. CARBON MONOXIDE - THE SILENT KILLER

2.1 WHAT IS CARBON MONOXIDE ? Congratulations on becoming the owner of an Ei Carbon Monoxide Alarm. This will help protect you and your household from the dangerous effects of Carbon Monoxide - The Silent Killer. Many are killed each year, and many more suffer ill health from Carbon Monoxide (CO) poisoning (CO is the chemical symbol, indicating the molecule has one carbon atom and one oxygen atom). CO is an invisible,

Ei Electronics Ei262 Many cases of reported Carbon Monoxide poisoning indicate that while victims are aware they are not

well, they become so disorientated they are unable to save themselves by either leaving the building or calling for assistance. Young children and household pets may be the first affected. Table A: Effects of Carbon Monoxide Poisoning 35 The maximum allowable concentration for continuous exposure in any 8 hour period according to OSHA *. 150 Slight head

2.3 WHAT HAPPENS WHEN YOUR CO ALARM DETECTS CARBON MONOXIDE ?

When the Ei262 CO Alarm detects potentally dangerous levels of CO, it flashes the red alarm light and then sounds a loud alarm if the CO persists and transmits a RadioLINK alarm signal. Table B below shows how the CO Alarm reacts to different levels of CO gas and exposure time. At higher levels of CO the alarm turns on sooner. The rate of flashing of the red light indicates the level of CO. Tabl

Ei Electronics Ei262 Pre-Alarm: When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps

locate CO leaks as the unit gives a visable indication straight away (the horn will not sound unless the 50ppm of CO remains for at least 90 mins). Note the Pre-Alarm signal may be triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a concern unless the Pre-Alarm signal persists until the al

Ei Electronics Ei262 3. ALARM POSITIONING

3.1 IDEALLY A CARBON MONOXIDE (CO) ALARM SHOULD BE INSTALLED IN: - Every room containing a fuel burning appliance - Remote rooms where occupants spend a considerable amount of time - Every bedroom However if the number of CO Alarms is limited, the following points should be considered when deciding where best to fit the alarm(s) - If there is an appliance in a room where people sleep, place a CO Alarm in this room - Locate a CO Alarm i

- Next to a door, window, air vent or anywhere that it would be affected by draughts

- Next to an extractor fan - Where it would be obstructed, e.g. by curtains or furniture - In an area where the temperature could drop below –10°C or rise above 40°C - Where dirt or dust could block the sensor - Where it could be easily knocked or damaged, or where it could be accidentally turned off or removed - In a bathroom or other areas where the CO Alarm may be e

1 to 3 m

1 to 3 m DEAD AIR DON'T LOCATE HERE CO Alarm Figure 1. Location in room with a fuel burning appliance - 1 to 3m from appliance - Ceiling 300mm (min) from walls - Wall 150mm vertically down from ceiling B16587-R0-262-UC-ENG 15/4/09 3:38 PM Page 11

Ei Electronics Smoke Alarm Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Ei150

Manual: Ei Electronics Ei150 (ZO486M, Upd.18-05-2026)

1 0.13 Mb 777 179 18-05-2026
Ei 405TY

#RIBV3N: Ei 405TY Smoke Alarm Instruction leaflet

24 0.46 Mb 1286 219 28-08-2026
EiA605MRF

Smoke Alarm #3K7O2R

12 290 56 11-07-2026
Ei3105RF

#2258L7: Ei3105RF Smoke Alarm Product manual

2 0.1 Mb 1387 306 26-06-2026
Ei 3100RF

User Manual: Ei Electronics Ei 3100RF (ISUQN8, Upd.29-05-2026)

20 1146 207 29-05-2026
Ei161RC

PDF Guide (@36T3T7), Ei Electronics Ei161RC Smoke Alarm (25-07-2026)

2 0.11 Mb 945 171 25-07-2026
Ei605MTYRF

Ei Electronics Ei605MTYRF Guide (Instructions manual), @LANO61

12 1.19 Mb 1089 240 11-10-2026
Ei208

PDF Manual (@GC759M), Ei Electronics Ei208 Smoke Alarm (07-09-2026)

32 0.34 Mb 636 128 07-09-2026
Ei166R

Ei Electronics Ei166R Guide (Quick start manual), @92AJEP

2 320 64 19-09-2026

Smoke Alarm: Similar Manuals