Text of Ei Electronics Ei262 User Instructions
Read and retain carefully for as long as the product is being used. Contains vital information on the
operation and installation. This leaflet should be regarded as part of the product.
If you are just installing the unit, this leaflet must be given to the householder. This leaflet is to be
given to any subsequent user.
The RadioLINK Carbon Monoxide Alarm Ei262 will
communicate with all other RadioLINK devices including
Smoke/Heat/Fire Alarms,
What to do when you alarm is activated
CARBON MONOXIDE - THE SILENT KILLER
ALARM POSITIONING
INSTALLATION
4.1 Mounting & Wiring Alarms
4.2 RadioLINK Interconnecting etc.
4.3 Hardwired Interconnect
USING & TESTING YOUR SYSTEM
HOW TO DISTINGUISH BETWEEN CO ALARM & SMOKE ALARM WARNINGS
MAINTENANCE
LIMITATIONS OF CO ALARMS
HOW TO PROTECT YOUR FAMILY
GETTING YOUR CO ALARM SERVICED
FIVE YEAR GUARANTEE
TECHNI
1. IMPORTANT INFORMATION
WARNING: The Alarm should be permanently wired to the mains by a qualified electrician in
accordance with IEE wiring regulations (BS7671).
Install a Carbon Monoxide (CO) Alarm in every room that contains a fuel burning appliance, and in
rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting rooms.
In rooms with an fuel burning appliance, install (preferably) on the ceiling (300mm from walls and
between 1m to 3m
Ei Electronics Ei262 WHAT TO DO WHEN THE CARBON MONOXIDE ALARM IS ACTIVATED:
(1) Open the doors and windows to ventilate the area.
(2) Turn off all fuel appliances where possible. (The alarm can be silenced immediately, with
low levels of CO, by pushing the Test/Hush button).
(3) Evacuate the property leaving the doors and windows open.
(4) Get medical help immediately for anyone suffering the effects of Carbon Monoxide
poisoning (headache, nausea), and advise that Carbon Mono
2. CARBON MONOXIDE - THE SILENT KILLER
2.1 WHAT IS CARBON MONOXIDE ?
Congratulations on becoming the owner of an Ei Carbon Monoxide Alarm. This will help protect you and
your household from the dangerous effects of Carbon Monoxide - The Silent Killer. Many are killed each
year, and many more suffer ill health from Carbon Monoxide (CO) poisoning (CO is the chemical symbol,
indicating the molecule has one carbon atom and one oxygen atom). CO is an invisible,
Ei Electronics Ei262 Many cases of reported Carbon Monoxide poisoning indicate that while victims are aware they are not
well, they become so disorientated they are unable to save themselves by either leaving the building or
calling for assistance. Young children and household pets may be the first affected.
Table A: Effects of Carbon Monoxide Poisoning
35
The maximum allowable concentration for continuous exposure in any 8 hour period according to OSHA *.
150
Slight head
2.3 WHAT HAPPENS WHEN YOUR CO ALARM DETECTS CARBON MONOXIDE ?
When the Ei262 CO Alarm detects potentally dangerous levels of CO, it flashes the red alarm light and
then sounds a loud alarm if the CO persists and transmits a RadioLINK alarm signal.
Table B below shows how the CO Alarm reacts to different levels of CO gas and exposure time. At higher
levels of CO the alarm turns on sooner. The rate of flashing of the red light indicates the level of CO.
Tabl
Ei Electronics Ei262 Pre-Alarm: When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps
locate CO leaks as the unit gives a visable indication straight away (the horn will not sound unless the
50ppm of CO remains for at least 90 mins). Note the Pre-Alarm signal may be triggered by CO coming
for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a
concern unless the Pre-Alarm signal persists until the al
Ei Electronics Ei262 3. ALARM POSITIONING
3.1 IDEALLY A CARBON MONOXIDE (CO) ALARM SHOULD BE INSTALLED IN:
- Every room containing a fuel burning appliance
- Remote rooms where occupants spend a considerable amount of time
- Every bedroom
However if the number of CO Alarms is limited, the following points should be considered when deciding
where best to fit the alarm(s)
- If there is an appliance in a room where people sleep, place a CO Alarm in this room
- Locate a CO Alarm i
- Next to a door, window, air vent or anywhere that it would be affected by draughts
- Next to an extractor fan
- Where it would be obstructed, e.g. by curtains or furniture
- In an area where the temperature could drop below –10°C or rise above 40°C
- Where dirt or dust could block the sensor
- Where it could be easily knocked or damaged, or where it could be accidentally turned off or removed
- In a bathroom or other areas where the CO Alarm may be e
1 to 3 m
1 to 3 m
DEAD AIR
DON'T LOCATE
HERE
CO Alarm
Figure 1. Location in room with a fuel burning appliance
- 1 to 3m from appliance
- Ceiling 300mm (min) from walls - Wall 150mm vertically down from ceiling
B16587-R0-262-UC-ENG 15/4/09 3:38 PM Page 11
Ei Electronics Smoke Alarm Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
Ei150 |
Manual: Ei Electronics Ei150 (ZO486M, Upd.18-05-2026) |
1 | 0.13 Mb | 777 | 179 | 18-05-2026 |
Ei 405TY |
#RIBV3N: Ei 405TY Smoke Alarm Instruction leaflet |
24 | 0.46 Mb | 1286 | 219 | 28-08-2026 |
EiA605MRF |
Smoke Alarm #3K7O2R |
12 | 290 | 56 | 11-07-2026 | |
Ei3105RF |
#2258L7: Ei3105RF Smoke Alarm Product manual |
2 | 0.1 Mb | 1387 | 306 | 26-06-2026 |
Ei 3100RF |
User Manual: Ei Electronics Ei 3100RF (ISUQN8, Upd.29-05-2026) |
20 | 1146 | 207 | 29-05-2026 | |
Ei161RC |
PDF Guide (@36T3T7), Ei Electronics Ei161RC Smoke Alarm (25-07-2026) |
2 | 0.11 Mb | 945 | 171 | 25-07-2026 |
Ei605MTYRF |
Ei Electronics Ei605MTYRF Guide (Instructions manual), @LANO61 |
12 | 1.19 Mb | 1089 | 240 | 11-10-2026 |
Ei208 |
PDF Manual (@GC759M), Ei Electronics Ei208 Smoke Alarm (07-09-2026) |
32 | 0.34 Mb | 636 | 128 | 07-09-2026 |
Ei166R |
Ei Electronics Ei166R Guide (Quick start manual), @92AJEP |
2 | 320 | 64 | 19-09-2026 |