Download SEFRAM DAS220BAT Manual (81 pages)Read Online:
Read the SEFRAM DAS220BAT Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
have to pay for some of them). Select the version you want according to the applications you
need. Just open the « VNC viewer » file where you recorded it. On the VNC Server line: you must type the IP address of your recorder and the password (the default password is « sefram »), then click « Connect » You will be able to control your recorder from your computer. ...
12.1. Measurement accuracy for thermocouple
The thermocouple measurements are treated as voltage measurements. For a given range of temperature measurement, the software calculates the voltage caliber the following way: * Let « T » the absolute value of the max. measurable value, in °C * Add 40°C to take the max. cold welding temperature into account * Search the corresponding voltage value U in the table of thermocouples * Program the caliber with U included in the range. Example: You want to program a measurement range between -50 and + 50°C with a J thermocouple: ...
5.1.2. Multiple thresholds
Trigger: Combination of analogic channels After selection of a trigger on a set of logic channels, the window allows you to set the trigger under several conditions. Then, by pressing the various thresholds in front of their respective channels, you open the threshold parameter window. One of the thresholds (or): the first achieved condition activates the trigger All thresholds (and): all conditions must be simultaneously achieved to validate the trigger A table makes it possible to select all channels and the validity of the channels Selecting t ...
9.5. Extension box input/output interface
The extension box input/output interface option (code 984405500) makes it possible to: Convert an alternating voltage (example 230V 50Hz) into a logic signal 1 Easy connection of the inputs of the 16 logic channels Insulation of the 16 logic inputs (250V=~ between channels, 250V=~ between channels and ground) Easy connection of the alarm outputs by a screw terminal Power supply of an external accessory with 3.3V, 5V or 12V by a screw terminal. Connection of the logic channels according to the signal voltage: 0 to 250V ...
12.2. Accuracy class – class index
This is one of the most important concepts of the CEI recommendation; it tends to shorten the list of specifications. To do so, it introduces the concept of PREDICTIVE CLASS that depends on the C CLASS INDEX. The normalized values of the class index are: C = 0.1, 0.25, 0.5 and 1. The intrinsic error (in the reference conditions) does not exceed + C % (the manufacturer may also specify this limit of the intrinsic error as an absolute value (ex. + 5 µV) for the first calibers). The variations (of the measured value) with the variations of one of th ...
9.2. Logic inputs
Inputs are according to the following circuit: Non-connected inputs are 0V potential (level 0). Number of logic channels: from 1 to 12. TTL level: 3.3V (protected up to 24V) To create a rising edge, you only have to place a connection between the power input and output of the connector. Similarly, to create a falling edge, you only have to remove this connection. You can also use an output signal TTL 3.3V. Plotting and display: They are displayed at the top or the bottom of the screen according to the selected position. They are numbered from the right to the left. ...
The appliance s equipped with a lithium-ion battery (Li-ion). It is sent with charged battery.
However, if the appliance has remained unused for more than one month, check its loading status and reload it if required. Security advice: Never heat up or throw the battery pack into fire Never shunt parts of the battery: risk of explosion! Do not bore the battery. Do not dismantle the battery pack. Do not reverse the polarities of the battery. This battery pack includes a protective item that shall not be damaged or removed. Do not store the pack i ...
The accuracy of the thermocouples is specified in append.
Compensation of the cold welding: ± 0.5°C 11.4. Pt100/Pt1000 Record Current generator: Pt100: 1mA Pt1000: 100µA Domain of use: -200°C to 850°C 2 wires or 3 wires Correction resistance in 2-wire mode: max. 30Ω max. resistance in 3-wire mode: 50Ω Accuracy at 20°C room temperature: ±0.3°C ± 0.1% of the measurement value 11.5. Resistance Probe Record 2 input ranges: 1kΩ: Current generator: 1mA Accuracy 1Ω 10kΩ Current generator: 100µA Accuracy 10Ω 11.6. Samp ...
SEFRAM DAS220BAT user guide recommended for: MW 3031, DAS30, 87, 9862, 70.
⚠️ Download Safety
The Measuring Instruments Operation & user’s manual (81 pages) is completely safe to download (last scan date: 17/03/2026).
Related PDF Instructions for SEFRAM DAS220BAT:
-
SEFRAM 7859 Measuring Instruments Operation & user’s manual
7859110 -
SEFRAM 9822 Thermometer Instruction manual
982224 -
SEFRAM 9893 Measuring Instruments Instruction manual
989323 -
SEFRAM MW 3031 Measuring Instruments Operation & user’s manual
MW 303130 -
SEFRAM 40 Test Equipment Manual
4020 -
SEFRAM MW 3517BF Measuring Instruments Operation & user’s manual
MW 3517BF57
Measuring Instruments Equipment: Frequently Requested
-
Anritsu MS2840A-040 Measuring Instruments
22.12.2025Comprehensive operating guide for the Anritsu MS2840A-040 Measuring Instruments. It details device setup and dimensions and layout, hardware components, functional overview, reset instructions.MS2840A-040, 8 -
DMP Electronics XR150FC Series Measuring Instruments
17.04.2026Owner’s manual for the DMP Electronics XR150FC Series Measuring Instruments. The document covers performance guidelines, safety protocols, troubleshooting guides, technical guidelines.XR150FC Series, 40 -
3M GMI PS200 Series Gas Detectors
18.01.2026Operation guide for the 3M GMI PS200 Series Gas Detectors. This manual covers installation, operation, and user settings, setup instructions, technical troubleshooting.GMI PS200 Series, 2 -
Amprobe SM-20-A Measuring Instruments
19.05.2026Installation and maintenance guide for the Amprobe SM-20-A Measuring Instruments. It offers guidance for setup and installation guides, device reset instructions, maintenance.SM-20-A, 50 -
Pentax FX-1DC Measuring Instruments
22.12.2025User guidebook for the Pentax FX-1DC Measuring Instruments. This guide includes detailed instructions for repair references, service procedures, user settings, operational guidelines.FX-1DC, 55 -
Rotronic hygrogen2 Portable Generator
15.05.2026Installation guide for the Rotronic hygrogen2 Portable Generator. It includes troubleshooting procedures and wiring diagrams, installation guides, startup procedures, supported accessories.hygrogen2, 46
Have some Questions about SEFRAM DAS220BAT Device?
Get valuable and actionable advices from other SEFRAM DAS220BAT device users. Describe your problem or question, regarding the using of DAS220BAT, in as much detail as possible, and other users will be able to answer you.