Seagate Exos CORVAULT Quick Configuration Manual

Text of the manual

Exos® CORVAULT Quick Configuration Guide

Part Number 83-00007918-00-01, A • December 2021 Storage enclosure management Select an interface that best fits your requirements to directly or remotely monitor and manage storage enclosure activity. Method Description Command-line interface (CLI)* Supports interactive and scripted commands Storage Management Console (SMC)* Provides web-based GUI JSON-based API Provides means to conduct JSON-based operations Redfish/Swordfish-based API Provides means to conduct Redfish/Swordfish operations XML-based Application Programming Interface (API) Provides means to conduct XML-based operations *Access method discussed in the following content Table 1 Interface options TIP Use the QR code on the included Getting Started sheet to access related storage enclosure documentation online. Command-line interface usage One of the simplest methods of monitoring and managing activities performed by the storage enclosure system is to use the command-line interface (CLI) embedded in each controller module. There are two primary access methods: l Direct connection to a controller module's serial USB port using a terminal emulator installed on a management host l Remote connection to a secure LAN using either SSH or HTTPS Item Description 1 Manufacturing service port: Do not use 2 Serial USB port for use with supplied serial cable 3 Ethernet port for connection to management host 4 SAS data ports for data exchange Figure 1 Ports on sample controller module

NOTE If the management host does not recognize the new controller or the connection, it cannot communicate with it.

All setup and configuration tasks identified in this section assume you have a direct connection between the management host and the controller using the supplied or a known good serial cable. The connection you establish is an out-of-band connection, since it does not use a data path to transfer information between the controller and the management host. The host computer or server can be either Linux- or Windows-based. Certain operating systems require a special mode of operation or the installation of a device driver. Install a device driver Some operating systems, such as a Windows OS that predates Windows 10/Server 2016, require download and installation of a device driver before the OS recognizes the USB device and can connect to a controller module. To install a device driver: 1. Navigate to https://www.seagate.com/support/systems/general-support/ and locate the device driver for download. 2. Download the zip file to the management computer. 3. Unzip the file, then click Setup.exe. 4. Follow all install instruction dialogs, clicking the prompts to run, accept, and install the device driver. 5. After successful completion of the install, close the dialog. 6. (Optional) Reset the management computer if required to complete installation and recognize the device driver. Configure the management host for serial communication After you successfully connect the supplied serial cable to the controller module, the management host should detect a new USB device. The next step is to establish communication between the management host and the controller module. Once you successfully install and run a supported terminal emulator, the controller presents a single serial port that uses the related USB vendor identification (ID) and product ID hex codes. Operating system Supported application Microsoft Windows (all versions) HyperTerminal, TeraTerm, PuTTY Linux (all versions) Minicom Table 2 Supported terminal emulator applications USB vendor identification code type Hex code USB vendor identification code 0x210C USB product identification code 0xA4A7 Table 3 Terminal emulator serial port hex codes Configure Linux for serial communication If you do not have a terminal emulator, such as Minicom, you must obtain one prior to completion of this task. To configure Linux for serial communication: IMPORTANT While Linux systems do not require installation of a device driver, it might require USB parameters as you load the device driver to enable controller recognition. modprobe usbserial vendor=0x210c product=0xa4a7 use_acm=1 You may also choose to incorporate the same information into the /etc/modules.conffile. 2

1. Determine if the operating system recognizes the USB (ACM) device by entering a command:

cat /proc/devices |grep -i "ttyACM" If the OS discovers a device driver, it responds with the device number followed by ttyACM, for example: 116 ttyACM 2. To query the system about USB buses and the devices connected to them, use the list USB command: lsusb If the OS discovers a USB device driver, it responds with the single serial port, using the USB parameter hex codes: ID 210c:a4a7 This confirms that the appropriate USB (ACM) device is visible to the management computer. 3. Invoke Minicom to configure it. minicom -s 4. Select Serial Port Setup from the menu. 5. Select the parameter setting you want to change at the prompt by typing the related setting letter (A-G). Setting Description Parameter settings A Serial device /dev/ttyACM0 B Lockfile location /var/lock C Callin program D Callout program E Bps/Par/Bits 11520 8N1 F Hardware flow control No G Software flow control No Table 4 Sample Linux Minicom serial port parameter settings 6. Press the ESC key to shift from the parameters to the configuration menu. 7. Select Save setup as dflto save the parameter settings to default. 8. Select Exit from Minicom. Configure Windows for serial communication Use the terminal emulator to launch the device driver window and directly communicate with each controller module, after meeting the following prerequisites: l An installed and tested terminal emulator. l An installed and tested Windows USB device driver to connect to the controller module USB port, by using the native USB serial driver for Windows 10/Server 2016 or higher, or by downloading and installing the Seagate device driver. To configure Windows for serial communication: 1. Start and configure the terminal emulator, using the specified settings. Parameter Value Parameter Value Connector COM3¹ Parity None Baud rate 115,200 Stop bits 1 Data bits 8 Flow control None ¹ Your configuration determines the COM port used for USB connection. Verify you have the correct COM port. Table 5 Terminal emulator port connection settings 2. In the terminal emulator, right-click on the connected and identified COM port and select Enable.

NOTE You must disable XON/XOFF when using Windows 10/Server 2016 with PuTTy so you can open the COM port.

3. For any hung connection, take the following corrective actions: a. Validate the terminal emulator configuration is correct and you selected the correct COM port. b. Quit the terminal emulator program. c. In the Windows Device Manager window, right-click on the problem COM port and select Disable. d. Confirm the COM port disabled status. e. Right-click on COM port you just disabled and select Enable to re-enable it. f. Start the terminal emulator program again and connect to the COM port, then validate the port settings again. Connect to a controller module for configuration When you first install a storage enclosure, you must perform some initial tasks to connect to and configure the system, such as setting up a user, log in, and setting a valid IP address for each controller module (CM) serial COM port. You have three options for setting up a network, each a viable approach to the same goal: connection to the CM. l Use a direct connection to the serial COM port to access the Storage Management Console (SMC). l Use a remotely connected network to access the SMC and connect to the CM through the identified factory default IP addresses. l Use secure shell (SSH) to access the SMC at the identified factory default IP addresses. > ssh 10.0.0.2 If the CM default IP address is not compatible with your network, you must manually set a valid IP address for each network port, once you have a good serial port connection to the management host. IP version Controller 0A addresses Controller 0B addresses IPv4 IP address: 10.0.0.2 IP address: 10.0.0.3 IP subnet mask: 255.255.255.0 IP subnet mask: 255.255.255.0 Gateway IP address: 10.0.0.1 Gateway IP address: 10.0.0.1 IPv6 Autoconfig: Enabled Autoconfig: Enabled Gateway: :: Gateway: :: Link-Local Address: fe80::2c0:ffff:fe44:952f Link-Local Address: fe80::2c0:ffff:fe44:7010 Autoconfig IP: 6::2c0:ffff:fe44:952f Autoconfig IP: 6::2c0:ffff:fe44:7017 Table 6 Factory default network port IP addresses To connect to a controller module for configuration: 1. Connect a serial cable from your management host to the CLI port on one of the CMs. 2. Launch the terminal emulator software and enable the CLI port for subsequent communication. 3. Press Enter to access the CLI prompt. 4. At the prompt, login with setup, press Enter, then press Enter again at the password prompt, for example: System Version: S100R009 OS Version: SPM100R009-01 MC Version: SXM100R009-01 Serial Number: 00C0FF535A86 SEAGATE00C0FF527EB8B login: setup Password: 4

5. For first time access to the SMC, enter Y at the prompt to continue.

6. To log in at the prompt, choose from one of the following actions: a. For first time access, create a user, such as manage, and follow the on-screen directions to create a user account. After doing so, the session will expire, and you can log in as the user you just created. b. For all subsequent log in activity, log in using valid system user credentials. 7. At the prompt, type the following command to set the IP address for each controller module or both controller modules: set network-parameters ip
netmask gateway controller a|b where:
is the IP address of the controller is the subnet mask is the IP address of the subnet router a|bspecifies the controller whose network parameters you are setting For an ipV4 static example: # set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1 controller a # set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway 192.168.0.1 controller b For a DHCP example: # set network-parameters dhcp controller a # set network-parameters dhcp controller b NOTE See the CLI Reference Guide for information about IPv6, and the commands used to add IPv6 addresses and set IPv6 network parameters. The ipv6term is included within each relevant command name. 8. Choose one of the following actions to verify the new IP address: a. For IPv4, use the show network-parameterscommand. b. For IPv6, use the show ipv6-network-parameterscommand. The result for each controller includes the IP address, subnet mask, and gateway address. 9. In the host computer's command window, first ping controller 0A and then controller 0B to verify connectivity. ping 10. When you are done using the CLI, exit the terminal emulator. 11. Retain the new IP addresses to access and manage the controllers by using either the SMC or the CLI. If you cannot access your system after changing the IP address and waiting up to two or three minutes, your network might require you to restart each affected Management Controller (MC) connected to the serial port. When you restart an MC, you temporarily lose communication with the MC until it successfully returns to a ready state. 12. (Optional) To restart the management controller on both controllers, type the following command : restart mc both If you lose communication with the CLI while using an out-of-band cable connection, you can often restore communication by disconnecting and reattaching the serial cable. After you initially set a controller IP address and have a functioning connection, you can change it later using the SMC.