Performance Tool M651 Owner's Manual

Text of the manual

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS AND

WARNINGS BEFORE OPERATING THIS TOOL. FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE AND WILL VOID WARRANTY. Some dust created by power sanding contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. An example of this type of chemical is lead from lead based paints, Crystalline Silica from bricks and cement or other masonry, Arsenic and Chromium from chemically treated lumber. Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure: work in a well ventilated area and work with approved safety equipment, such as dusk masks that are specially designed to filter out microscopic particles. 1/2" DR. REVERSIBLE AIR DRILL OWNER’S MANUAL Stock Number M651 SPECIFICATIONS: Chuck Size (IN.) ................................................................................1/2 Air pressure (P.S.I.) .............................................................................90 Average air consumption (C.F.M.) .......................................................4 Free speed (R.P.M.) .........................................................................600 Air inlet (N.P.T.) ..................................................................................1/4 Hose size (I.D.) .............................................................................3/8 in. Length (IN.) .......................................................................................8.9 Weight (LBS.) ..................................................................................3.57 Specifications are subject to change without notice. LIMITED WARRANTY PERFORMANCE TOOL® extends only the following warranties, and only to original retail purchasers. These warranties give specific legal rights. Except where prohibited by local law, the law of the State of Washington governs all warranties and all exclusions and limitations of warranties and remedies. There may be other rights which vary from state to state. PERFORMANCE TOOL® warrants the product to be free from defects in materials and workmanship under normal use and service. A defective product may be returned for a free replacement within 90 days from the date of purchase, provided that product is returned to place of purchase immediately after discovery of defect. After 90 days and up to one year from date of purchase, PERFORMANCE TOOL® will replace at no charge any parts which our examination shall disclose to be defective and under warranty. These warranties shall be valid only when a sales receipt showing the date of purchase accompanies the defective product or defective part (s) being returned. For part (s) after 90 days, please remit your request, postage prepaid to: PERFORMANCE TOOL, P.O. Box 88259 Tukwila, WA 98138 These warranties exclude blades, bits, punches, dies, bulbs, fuses, hoses, and other consumables which must be replaced under normal use and service. These warranties shall not apply to any product or part which is used for a purpose for which it is not designed, or which has been repaired or altered in any way so as to affect adversely its performance or reliability, nor shall these warranties apply to any product or part which has been subject to misuse, neglect, accident or wear and tear incident to normal use and service. PERFORMANCE TOOL® does not authorize any other person to make any warranty or to assume any liability in connection with its products. Except for warranties of title and the limited express warranties set forth above, PERFORMANCE TOOL® makes no express or implied warranties of any kind with respect to its products. In particular, PERFORMANCE TOOL® makes no implied warranty of merchantability and no implied warranty of fitness for any particular purpose, except that for goods purchased primarily for personal, family or household use and not for commercial or business use, PERFORMANCE TOOL® makes an implied warranty of merchantability (and, if otherwise applicable, an implied warranty of fitness for a particular purpose), but only for the particular qualities or characteristics, and for the duration, expressly warranted above. The laws on limitation of implied warranties may differ from state to state, so the above limitations may not apply in all cases. PERFORMANCE TOOL® shall not be liable for consequential, incidental or special damages resulting from or in any manner related to any product, or to the design, use, or any inability to use the product. The sole and exclusive remedy for a defective product or part shall be the repair, or replacement thereof as provided above. The laws on limitation of remedies or on consequential, incidental or special damages may vary from state to state, so the above limitations may not apply in all cases. © Copyright 2016 WILMAR CORPORATION, P.O. Box 88259 Tukwila, WA 98138

1. Be sure air is in "OFF" position when connecting tool to air supply.

2. Always wear approved eye protection when using air tools. If raising dust, wear a suitable mask. WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities, contain chemicals known [to the State of California] to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are: 1. Lead from lead-based paints; 2. Crystalline silica from bricks and cement or other masonry products; 3. Arsenic and chromium from chemically treated lumber. Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles. 3. Use only those accessories that are designed for use with air tools. For example, with impact wrenches do not use ordinary sockets. Use impact sockets for all- air tools. 4. Be sure to disconnect tool from air supply before changing accessories, performing service on tool and when not in use. 5. As with any tool, use common sense when operating. Do not wear loose clothing or jewelry that could become caught by moving parts, causing injury. Operate tool a safe distance from yourself and others in the work area. 6. To ensure long life of the air tool be sure to oil the tool daily before using. See below for instructions. 7. Follow air source manufacturers directions for connection of regulators, filters, and other accessories to air source. Do not install quick couplers directly on tool as they put unnecessary strain on the air inlet threads possibly causing them to wear out prematurely. Instead, install them on a short length of air hose attached to the tool. 1. Use of a center punch to mark the starting point of a hole is recommended when drilling metals with this tool. Place drill against work before starting motor. Do not apply too much pressure to the drill as this can cause the bit to overheat and break. When the hole is drilled, do not stop the drill until it is withdrawn from work. 2. If the drill should bind and stop inside the work, release the trigger immediately and determine the cause. If removal of bit from the drill is necessary, disconnect the drill from the air source before removing. Do not attempt to free the bit by forcing it with the drill. 3. A forward and reverse lever permits the tool to run in a forward (clockwise) rotation or in reverse (Counter-clockwise) rotation. Do not attempt to change direction while tool is running. IMPORTANT SAFETY INFORMATION OPERATION Clean air of correct air pressure is recommended for the power supply for this tool. A maximum of 90 PSI at the tool is recommended for most air tools of this class. Check specifications section for recommended pressure. (Depending on length of air hose and other circumstances, air pressure at compressor may need to be increased to 100 PSI to ensure 90 PSI at the tool.) Water in the air hose and compressor tank contributes to reduced performance and damage of the air tool. Drain the air tank and filters before each use and as necessary to keep the air supply dry. Hose length over 25’ causes loss in line pressure. Increase hose I.D. or increase compressor pressure to compensate for the pressure loss. Use an in-line pressure regulator with gauge if air inlet pressure is critical. AIR SOURCE Oil tool before each use. 4 to 5 drops of a good grade Air Tool Oil placed in the air inlet is sufficient. Use proper air pressure and CFM rating listed for this tool. Drain water from hoses and compressor tank. Water in the air supply line will cause gumming and loss of power. Clean the air filter on the supply line and flush the tool with gum solvent or a 50/50 mix of air tool oil and kerosene. It may be necessary to disassemble the tool to properly clean and re-lubricate. LUBRICATION & MAINTENANCE Forward/Reverse Lever Air Inlet Trigger INSUFFICIENT POWER: Probable Cause Solution Dirty or clogged air passages......... Flush and lubricate tool, drain air tank and supply line Insufficient air supply ...................... Increase line pressure, Make sure compressor matches tool's air pressure and consumption needs Air leakage ...................................... Use Teflon tape at all fittings and joints. Check tool for worn or damaged O-rings & seals. Worn/damaged wear & tear parts .. Replace as necessary. Tool matching ................................. Be sure you are using a tool suited for the torque requirements of the job at hand. TROUBLESHOOTING Motor Oil Trans. Fluid Brake Fluid Water Whip hose Air Tool Oil Yes No 1 2

1/2 in. Chuck

1 36 Chuck Screw 1 37 Handle 1 38 Handle Collar 1 39 Chuck Key 1 PARTS LIST 33 32 31 30 29 28 27 26 25 33 24 17 23 22 20 21 19 18 17 16 10 11 9 8 7 6 4 3 5 2 12 13 15 14 28 27 25 32 34 35 36 37 38 39 INDEX DESCRIPTION QTY INDEX DESCRIPTION QTY 3 4

Other Drill Manuals