Schlage M390RFK Installation Instructions
Text of the manual
Includes 1/4" (6.4 mm) mounting bracket
Lock Dimensions
1 5/8" D x 2 7/8" W x 10 1/2" L
(41 mm x 73 mm x 268 mm)
Armature
Dimensions
Plate
5/8" D x 2 3/8" W x 7 7/16" L
(16.5 mm x 61 mm x 190 mm)
Housing
3/4" D x 2 11/16" W x 10 3/8" L
Environmental
• Not for use in outdoor
environments.
• Circuit board operating
temperature: 14 to 140°F
(-10 to 60°C)
Electrical:
Contacts rated for 0.20A at 12VDC and 0.12A at 24VDC
Voltage
Auto sensing 12VDC or 24VDC
Current
0.65A at 12VDC or 0.45A at 24VDC
MBS Output Relay*
SPDT relay. Contacts rated at 1.25A at
24VDC
DSM Reed Switch*
Magnetically actuated SPDT switch.
* Effective for either resistive or inductive loads (power factor ≥ 0.6 with
inductive loads). Specifications may change without notice.
Wiring Requirements
Wire gauges shown reference the load of a single lock.
VDC
0-100’
200’ max
300’ max
12
16 Gauge
12 Gauge
12 Gauge
24
18 Gauge
18 Gauge
16 Gauge
Features
Lock Monitoring
Features
Remote indication features that provide
indication as to the lock status.
Magnetic Bond
Sensor (MBS)
Detects proper bond between magnet and
armature. It can be monitored remotely and
locally with an LED.
Door Status
Monitor (DSM)
Monitors the position of the door. An SPDT
reed switch mounted within the lock cavity
eliminates the need for extra sensors to be
installed on the door for notification of
security or access control systems.
Relock Time Delay
(RTD)
Relock time can be changed. Range is 0 -
110 seconds.
Listings
These products have been
successfully tested and
evaluated by UL in two
separate categories for use in
both the United States and
Canada.
Auxiliary Lock:
The GWXT fire
listing qualifies the
M390RFK lock for
use with UL
Classified fire doors maximum
4’ in width and 8’ in height,
rated up to and including 3
hours.
Special Locking Arrangement
Component:
These products
are qualified
components
for the purpose of locking
outward-swinging exit doors
against unauthorized egress.
They are designed to release
automatically in case of a
power failure or upon
activation of an automatic fire
alarm system wired to the
power supply fire panel relay.
The Following Conditions of
Acceptability Apply:
This product is intended for
use with Special Locking
Arrangements which are
installed in accordance with
the manufacturer’s
installation and operation
instructions, the Life Safety
Code, NFPA 101 of the National
Fire Protection Association
and the local authority having
jurisdiction.
The power for this unit is to be
provided by a Listed (ALVY,
ALVY7, FULA, FULA7, FUPPC,
UEHX7, APHV, or APHV7)
Class 2 power supply when
designated as a Special
Locking Arrangement (FWAX
or FWAX7).
The suitability of the lead
wires is to be evaluated per
the requirements for the
end-use product.
When this product is installed
in conjunction with a fire alarm
control panel, the wiring from
the control unit to this product
device shall be for fail-safe
operation.
For Canadian Installations,
this product is to be installed
in accordance with the
manufacturer’s installation
and operation instructions,
The Canadian Electrical Code
C22.1-02, and the local
authority having jurisdiction.
To qualify for use in a delayed-
egress locking system, the
relock delay must be set to 0
seconds.
These locks are not intended
or tested for use as a UL Listed
Burglar Alarm System Unit.
ANSI/BHMA Testing:
These models
have also been
independently
tested to the ANSI/BHMA
A156.23-2010 American
National Standard for
Electromechanical Locks.
Holding Force: 1500lbf
Cycle Test:
Grade 1 = 1 million cycles
Power Supply:
Voltage
M390RFK
12VDC
0.65A
24VDC
0.45A
All Schlage electromagnetic
locks must be powered with a
Listed filtered and regulated
DC power supply such as the
Schlage PS900 Series of UL
Listed power supplies.
Inspection and Maintenance
This product must be inspected and maintained on a quarterly
basis. Contacting surfaces of the electromagnetic lock and
armature plate must be kept free of contaminating materials.
Surfaces must be cleaned periodically with a non-abrasive
cleaner.
All mounting fasteners must be inspected on a quarterly
basis.
When properly installed, the ends of the armature plate allow
a slight movement but the plate will feel secure when grasped
at the bolt. There should be no movement to the mounting
bracket or housing of the electromagnetic lock.
For added safety, thread locking compound has been provided
for the armature plate bolt and the four captive
electromagnetic lock mounting screws.
Warnings and Cautions
WARNING
Warnings indicate potentially hazardous conditions, which if
not avoided or corrected, may cause death or serious injury.
CAUTION
Cautions indicate potentially hazardous conditions, which if
not avoided or corrected, may cause minor or moderate
injury. Cautions may also warn against unsafe practices.
L
Notes indicate a condition that may cause
equipment or property damage only.
Pre-Installation Considerations
CAUTION
• Use ONLY the hardware provided for mounting this
product.
• Non-standard Door thickness may require different
barrel nut hardware - see specific instructions for
required hardware.
• Follow the installation procedure as described in this
manual.
• Check door thickness. If the door is not 1 3/4" thick, a
different barrel nut will be required. Contact Product
Support at 1-877-671-7011.
• Check door header. A minimum 2 3/4" thick, flat surface is
needed to securely mount all screws for the magnet. If
you do not have the required surface, you will need filler
plates and/or angle brackets to properly mount the
magnet. Contact Product Support at 1-877-671-7011.
Door: 1 3/4" Thick
Header: At least 2
3/4" thick, flat
Lock Installation
1 Prepare door and frame (for new installs).
1a
Place included template against closed door and header
with allowance for Allen key clearance from the edge (1 1/4”).
1b
Drill the middle hole in the door and two (2) holes in the
header as indicated. Center-mark the two holes to mount
armature holder.
L
Different hole sizes required for different materials,
as referenced on the template.
Figure 1: Armature Mounting
Metal door reinforcement tube
Armature housing
Tooth lock washer
Screw
Rubber coated head
Armature
Steel washers
Barrel
Nut
2 Mount armature plate.
2a Position screw with rubber head through the armature plate.
L
Apply thread-locking compound to exposed
threads.
2b Secure armature plate to door and armature holder by
threading into barrel nut. See Figure 1: Armature
Mounting.
L
Armature plate must be allowed to pivot on the
center mounting bolt to allow proper alignment
with the magnet surface. If the plate is not aligned
with the magnet surface, the lock may lose holding
force or not lock at all.
L
The head of the armature mounting bolt ships with
a rubber washer affixed to it. This washer should
project beyond the surface of the armature plate to
allow the washer to expand when power is
removed and break the air vacuum between the
plate and magnet surface. If this washer is
removed or trimmed, the lock will appear to have
some holding force even when power is removed
3 Mount lock.
3a Remove blocking screws from front of lock.
3b Remove lock from mounting bracket by loosening captive screws and sliding off keyholes.
New lock installation:
3c Attach bracket to header with the two (2) panhead
machine screws or the self-drilling screws provided through
the slots.
L
Do not over-tighten these screws as the bracket
may need adjustment.
L
Mounting Bracket should be installed such that the
Panhead screwheads fit within the recessed area
of the slot.
3d Slide lock onto mounting bracket keyholes. Engage one
captive screw at each end through bottom to fix lock
position on bracket.
3e Adjust alignment to ensure full contact of magnet with
armature plate.
3f
Carefully remove lock without shifting mounting bracket and
tighten panhead screws as needed to secure in place.
3g Secure mounting bracket in position with either nine (9)
TEK™ screws or four (4) at counter-sunk machine screws.
3h Drill ¾” (19 mm) wire access hole using mounting bracket as
a guide.
3i
Tip the lock to expose the four (4) captive mounting screws.
L
Apply thread-locking compound to exposed
threads.
3j
Slide the lock onto mounting bracket keyholes.
3k Tighten the four (4) captive mounting screws.
3l
Insert anti-tamper plugs.
Retrofit installation:
3c Attach bracket to header with 9 TEK™ screws or four (4) at
counter-sunk machine screws utilizing holes from previous
installation.
L
Additional TEK™ screws may be used for added
strength.
3d Tip the lock to expose the four (4) captive mounting screws.
L
Apply thread-locking compound to exposed
threads.
3e Slide the lock onto mounting bracket keyholes.
3f
Tighten the four (4) captive mounting screws.
3g Insert anti-tamper plugs.
Captive
mounting screw
Blocking screw
Blocking
and wiring
cavity screw
Insert anti-tamper plugs
Figure 2: Lock Mounting
Keyholes
Wire access
holes
Slots
4 Route the power supply.
Connect wire through the door frame and into the wire access
hole in the top of the magnet housing. See Wiring
Requirements on page 1 for current draw specifications
and wiring gauge chart.
CAUTION
This electromagnetic locking device is cULus listed and
must be used with UL approved power supply.
5 Connect wire to terminal blocks.
5a Route wire into lock cavity. Connect wire to terminal blocks.
See Figure 3: Lock Wiring.
5b Wire Door Status Monitor (DSM) and/or Magnetic Bond
Sensor (MBS) if used. See Figure 3: Lock Wiring.
Figure 3: Lock Wiring
DELAY
J2
RW1
MAG
LED 1
NO
NC
C –
+
Normally open
Normally closed
Common
Common ground
12/24 VDC input
MBS sensor SPDT
output contacts rated for
max 1.25 amp at 24 VDC
Lock powered from a
listed filtered and
regulated DC power
supply
DSM reed switch contacts rated at 0.20
amp and 12 VDC and 0.12 amp at 24 VDC
Red: normally closed
Green: normally open
Black: common
RTD adjustment
Turn clockwise to
increase delay.
© Allegion 2021
Printed in U.S.A.
24200669 Rev. 09/21-d
Customer Service
1-877-671-7011
www.allegion.com/us
6 Ensure instant release.
All switching devices must be wired between the DC power
source and the positive terminal of the lock as shown in Figure
4: Power Connections. Switching the negative power supply
line will not allow the lock to release immediately.
L
This lock contains TVS for surge suppression and
does not require any additional suppression.
L
Note: Some warming of the device under routine
operation is normal.
Figure 4: Power Connections
+
-
Correct
switch
Filtered DC supply
+
-
Incorrect
Filtered DC supply
switch
Troubleshooting
Problem
Solution
Cannot remove the lock mounting bracket
from top of magnet for installation.
Remove blocking screw. Insert supplied Allen wrench into mounting bolt holes in the
bottom of the lock housing and turn. See Figure 2: Lock Mounting on page 3.
Lock is installed but has no holding force at
all.
Check connections at power supply, connected releasing devices, lock terminals, and
lock circuit board to magnet core.
Lock has enough holding force to lightly
hold a screwdriver or set of pliers but door
will not lock.
Check to see that armature plate is correctly aligned with the electromagnetic lock. If
there is improper alignment, make a 1/4” turn of the armature plate mounting bolt and
check for alignment. Make sure to follow the armature plate mounting instructions
on the template and page 1 of these installation instructions.
Lock is operating and locking but the
armature plate is “humming” against the
surface of the lock.
This generally indicates that the lock is either operating on AC voltage or there is
some AC voltage present in the DC supply. A properly filtered and regulated DC
power supply is required to achieve optimal operation from the lock.
Lock is not releasing immediately upon
removal of power.
Ensure that switching devices are interrupting the DC power and not the AC power
supply voltage. Ensure rubber washer on armature plate mounting bolt has not been
removed or damaged. Check that switching device interrupts the positive wire and
not the negative wire. See Figure 4: Power Connections on page 4. Remove any
Diodes or other suppression devices that may be installed.
D > Revised artwork
1. Fold booklet style
A
B
C
D
E
F
030274
061317
n/a
091925
Material
White Paper
Edited By
Approved By
EC Number
Release Date
M. Sasso
D. Toppins
091925
09-27-21
Notes
1. printed two sides
2. printed black
3. tolerance ± .13
4. printed in country may vary
5. drawings not to scale
Title
INSTRUCTION SHEET, INSTALLATION, M390RFK
Creation Date
11-06-12
Number
24200669
Revision
D
Created By
D. Spence
Activity
3899 Hancock Expwy
Security, CO 80911
© Allegion 2021
Software: InDesign CS6
16.535
11.693
BEGINNING SHEET
FRONT
8.268
11.693
FOLDED SHEET
FRONT