Datalogic POWERSCAN PD7100 Product Reference Manual

Text of the manual

Datalogic Scanning, Inc.

959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non- exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representa- tive. Electronic versions may either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Data- logic reserves the right to change any specification at any time without prior notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic S.p.A. All other brand and product names referred to herein may be trademarks of their respective owners. This product may be covered by one or more of the following patents: 4603262 • 4639606 • 4652750 • 4672215 • 4699447 • 4709369 • 4749879 • 4786798 • 4792666 • 4794240 • 4798943 • 4799164 • 4820911 • 4845349 • 4861972 • 4861973 • 4866257 • 4868836 • 4879456 • 4939355 • 4939356 • 4943127 • 4963719 • 4971176 • 4971177 • 4991692 • 5001406 • 5015831 • 5019697 • 5019698 • 5086879 • 5115120 • 5144118 • 5146463 • 5179270 • 5198649 • 5200597 • 5202784 • 5208449 • 5210397 • 5212371 • 5212372 • 5214270 • 5229590 • 5231293 • 5232185 • 5233169 • 5235168 • 5237161 • 5237162 • 5239165 • 5247161 • 5256864 • 5258604 • 5258699 • 5260554 • 5274219 • 5296689 • 5298728 • 5311000 • 5327451 • 5329103 • 5330370 • 5347113 • 5347121 • 5371361 • 5382783 • 5386105 • 5389917 • 5410108 • 5420410 • 5422472 • 5426507 • 5438187 • 5440110 • 5440111 • 5446271 • 5446749 • 5448050 • 5463211 • 5475206 • 5475207 • 5479011 • 5481098 • 5491328 • 5493108 • 5504350 • 5508505 • 5512740 • 5541397 • 5552593 • 5557095 • 5563402 • 5565668 • 5576531 • 5581707 • 5594231 • 5594441 • 5598070 • 5602376 • 5608201 • 5608399 • 5612529 • 5629510 • 5635699 • 5641958 • 5646391 • 5661435 • 5664231 • 5666045 • 5671374 • 5675138 • 5682028 • 5686716 • 5696370 • 5703347 • 5705802 • 5714750 • 5717194 • 5723852 • 5750976 • 5767502 • 5770847 • 5786581 • 5786585 • 5787103 • 5789732 • 5796222 • 5804809 • 5814803 • 5814804 • 5821721 • 5822343 • 5825009 • 5834708 • 5834750 • 5837983 • 5837988 • 5852286 • 5864129 • 5869827 • 5874722 • 5883370 • 5905249 • 5907147 • 5923023 • 5925868 • 5929421 • 5945670 • 5959284 • 5962838 • 5979769 • 6000619 • 6006991 • 6012639 • 6016135 • 6024284 • 6041374 • 6042012 • 6045044 • 6047889 • 6047894 • 6056198 • 6065676 • 6069696 • 6073849 • 6073851 • 6094288 • 6112993 • 6129279 • 6129282 • 6134039 • 6142376 • 6152368 • 6152372 • 6155488 • 6166375 • 6169614 • 6173894 • 6176429 • 6188500 • 6189784 • 6213397 • 6223986 • 6230975 • 6230976 • 6244510 • 6259545 • 6260763 • 6266175 • 6273336 • 6276605 • 6279829 • 6290134 • 6290135 • 6293467 • 6303927 • 6311895 • 6318634 • 6328216 • 6332576 • 6332577 • 6343741 • 6454168 • 6478224 • 6568598 • 6578765 • 6705527 • 6857567 • 6974084 • 6991169 • 7051940 • 7170414 • 7172123 • 7201322 • 7204422 • 7215493 • 7224540 • 7234641 • 7243850 • 7374092 • 7407096 • 601 26 118.6 • AU703547 • D312631 • D313590 • D320011 • D320012 • D323492 • D330707 • D330708 • D349109 • D350127 • D350735 • D351149 • D351150 • D352936 • D352937 • D352938 • D352939 • D358588 • D361565 • D372234 • D374630 • D374869 • D375493 • D376357 • D377345 • D377346 • D377347 • D377348 • D388075 • D446524 • EP0256296 • EP0260155 • EP0260156 • EP0295936 • EP0325469 • EP0349770 • EP0368254 • EP0442215 • EP0498366 • EP0531645 • EP0663643 • EP0698251 • EP01330772 • GB2252333 • GB2284086 • GB2301691 • GB2304954 • GB2307093 • GB2308267 • GB2308678 • GB2319103 • GB2333163 • GB2343079 • GB2344486 • GB2345568 • GB2354340 • ISR107546 • ISR118507 • ISR118508 • JP1962823 • JP1971216 • JP2513442 • JP2732459 • JP2829331 • JP2953593 • JP2964278 • MEX185552 • MEX187245 • RE37166 • RE40.071 • Other Patents Pending

Product Reference Guide

1 Table of Contents Chapter 1. Introduction.............................................................................................................. 1 About this Guide .................................................................................................................... 1 Manual Overview ................................................................................................................... 1 Manual Conventions ............................................................................................................... 2 References ............................................................................................................................ 2 Technical Support .................................................................................................................. 3 Datalogic Website Support ................................................................................................. 3 Reseller Technical Support ................................................................................................. 3 Telephone Technical Support .............................................................................................. 3 Chapter 2. Getting Started ......................................................................................................... 5 About the Reader ................................................................................................................... 5 Unpacking ............................................................................................................................. 5 Setting Up the Reader ............................................................................................................ 6 Install the Interface Cable ................................................................................................. 6 Programming ................................................................................................................... 7 Using the Programming Barcodes ....................................................................................... 8 Select the Interface Type ................................................................................................... 8 Configure Interface Settings .............................................................................................. 8 Configure Other Features ................................................................................................... 8 Resetting the Standard Product Defaults ................................................................................... 9 Chapter 3. Interfaces ............................................................................................................... 11 Interface Selection ................................................................................................................11 Configuring the Interface .......................................................................................................11 Global Interface Features .......................................................................................................15 Host Commands — Obey/Ignore ........................................................................................15 USB Suspend Mode ..........................................................................................................16 Chapter 4. General Features..................................................................................................... 17 Double Read Timeout ............................................................................................................17 Label Gone Timeout ..............................................................................................................19 Sleep Mode Timeout ..............................................................................................................21 LED and Beeper Indicators .....................................................................................................23 Power On Alert ................................................................................................................23 Good Read: When to Indicate ............................................................................................24 Good Read Beep Type ......................................................................................................25 Good Read Beep Frequency ..............................................................................................26 Good Read Beep Length ...................................................................................................26 Good Read Beep Volume ..................................................................................................28 Good Read LED Duration ..................................................................................................29 Scanning Features ................................................................................................................31 Scan Mode ......................................................................................................................31 Stand Mode Triggered Timeout ..........................................................................................33 Scanning Active Time .......................................................................................................35 Flash On Time ......................................................................................................................37 Flash Off Time ......................................................................................................................39 Stand Mode Sensitivity ..........................................................................................................41 Laser Pointer Control .............................................................................................................42 Laser Pointer Period ..............................................................................................................43 Green Spot Duration ..............................................................................................................45

PowerScan® PD7100 Corded

Chapter 5. RS-232 ONLY Interface........................................................................................... 47 Introduction ......................................................................................................................... 47 RS-232 Standard Factory Settings .......................................................................................... 47 Baud Rate ........................................................................................................................... 47 Data Bits ............................................................................................................................. 49 Stop Bits ............................................................................................................................. 50 Parity .................................................................................................................................. 51 Handshaking Control ............................................................................................................. 52 Chapter 6. RS-232/USB-Com Interfaces.................................................................................. 53 Introduction ......................................................................................................................... 53 Standard Factory Settings ..................................................................................................... 53 Intercharacter Delay ............................................................................................................. 54 Beep On ASCII BEL ............................................................................................................... 56 Beep On Not on File .............................................................................................................. 56 ACK NAK Options .................................................................................................................. 57 ACK Character ................................................................................................................ 58 NAK Character ................................................................................................................ 60 ACK NAK Timeout Value ................................................................................................... 62 ACK NAK Retry Count ...................................................................................................... 64 ACK NAK Error Handling ................................................................................................... 66 Indicate Transmission Failure ................................................................................................. 67 Disable Character ................................................................................................................. 68 Enable Character .................................................................................................................. 70 Chapter 7. Keyboard Interface................................................................................................. 73 Introduction ......................................................................................................................... 73 Standard Factory Settings ..................................................................................................... 73 Scancode Tables ................................................................................................................... 73 Country Mode ...................................................................................................................... 74 Caps Lock State ................................................................................................................... 77 Numlock .............................................................................................................................. 77 Send Control Characters ........................................................................................................ 78 Wedge Quiet Interval ............................................................................................................ 79 Intercharacter Delay ............................................................................................................. 81 Intercode Delay .................................................................................................................... 83 USB Keyboard Speed ............................................................................................................ 85 Chapter 8. USB-OEM Interface................................................................................................. 87 Introduction ......................................................................................................................... 87 Standard Factory Settings ..................................................................................................... 87 USB-OEM Device Usage ......................................................................................................... 88 Chapter 9. IBM 46XX Interface ................................................................................................ 89 Introduction ......................................................................................................................... 89 IBM Standard Factory Settings ............................................................................................... 89 46xx Number of Host Resets .................................................................................................. 90 Transmit Labels in Code 39 Format ......................................................................................... 93 Chapter 10. Data Editing.......................................................................................................... 95 Data Editing Overview ........................................................................................................... 95 Please Keep In Mind... ........................................................................................................... 96 Global Prefix/Suffix ............................................................................................................... 96 Example: Setting a Prefix ................................................................................................. 96 Global AIM ID ...................................................................................................................... 98 GS1-128 AIM ID ................................................................................................................. 100 Label ID ............................................................................................................................ 101 Label ID: Pre-loaded Sets .............................................................................................. 101 Label ID: Set Individually Per Symbology ......................................................................... 103

Product Reference Guide

3 Label ID Control ............................................................................................................105 Label ID Symbology Selection .........................................................................................106 Case Conversion .................................................................................................................112 Character Conversion ..........................................................................................................112 Chapter 11. Symbologies ....................................................................................................... 115 Introduction .......................................................................................................................115 1D Symbologies ............................................................................................................115 Standard Factory Settings for Symbologies .............................................................................115 UPC-A ...............................................................................................................................116 UPC-A Enable/Disable ....................................................................................................116 UPC-A Check Character Transmission ...............................................................................116 Expand UPC-A to EAN-13 ................................................................................................117 UPC-A Number System Character Transmission .................................................................117 In-Store Minimum Reads ................................................................................................118 UPC-E ...............................................................................................................................119 UPC-E Enable/Disable ....................................................................................................119 UPC-E Check Character Transmission ...............................................................................119 Expand UPC-E to EAN-13 ................................................................................................120 Expand UPC-E to UPC-A .................................................................................................120 UPC-E Number System Character Transmission .................................................................121 UPC-E Minimum Reads ...................................................................................................122 GTIN Formatting .................................................................................................................123 EAN 13 ..............................................................................................................................124 EAN 13 Enable/Disable ...................................................................................................124 EAN 13 Check Character Transmission ..............................................................................124 EAN-13 Flag 1 Character ................................................................................................125 EAN-13 ISBN Conversion ................................................................................................126 EAN 13 Minimum Reads .................................................................................................127 EAN 8 ................................................................................................................................128 EAN 8 Enable/Disable .....................................................................................................128 EAN 8 Check Character Transmission ...............................................................................128 Expand EAN 8 to EAN 13 ................................................................................................129 EAN 8 Minimum Reads ...................................................................................................130 UPC/EAN Global Settings ......................................................................................................131 UPC/EAN Decoding Level ................................................................................................131 UPC/EAN Correlation ......................................................................................................133 UPC/EAN Reconstruction .................................................................................................133 UPC/EAN Price Weight Check ..........................................................................................134 UPC-A Minimum Reads ...................................................................................................135 Add-Ons ............................................................................................................................136 Optional Add-ons ...........................................................................................................136 Optional Add-On Timer ...................................................................................................138 Optional GS1-128 Add-On Timer .....................................................................................141 P2 Add-Ons Minimum Reads ...........................................................................................144 P5 Add-Ons Minimum Reads ...........................................................................................145 GS1-128 Add-Ons Minimum Reads ...................................................................................146 GS1 DataBar Omnidirectional ...............................................................................................147 GS1 DataBar Omnidirectional Enable/Disable ....................................................................147 GS1 DataBar Omnidirectional GS1-128 Emulation ..............................................................147 GS1 DataBar Omnidirectional Minimum Reads ...................................................................148 GS1 DataBar Expanded ........................................................................................................149 GS1 DataBar Expanded Enable/Disable .............................................................................149 GS1 DataBar Expanded GS1-128 Emulation ......................................................................149 GS1 DataBar Expanded Minimum Reads ...........................................................................150 GS1 DataBar Expanded Length Control .............................................................................151 GS1 DataBar Expanded Set Length 1 ...............................................................................152 GS1 DataBar Expanded Set Length 2 ...............................................................................154 GS1 DataBar Limited ...........................................................................................................156

PowerScan® PD7100 Corded

GS1 DataBar Limited Enable/Disable ............................................................................... 156 GS1 DataBar Limited GS1-128 Emulation ......................................................................... 156 GS1 DataBar Limited Minimum Reads .............................................................................. 157 Code 39 ............................................................................................................................ 158 Code 39 Enable/Disable ................................................................................................. 158 Code 39 Check Character Calculation ............................................................................... 159 Code 39 Check Character Transmission ............................................................................ 160 Code 39 Start/Stop Character Transmission ...................................................................... 160 Code 39 Full ASCII ........................................................................................................ 161 Code 39 Quiet Zones ..................................................................................................... 162 Code 39 Minimum Reads ................................................................................................ 163 Code 39 Decoding Level ................................................................................................. 164 Code 39 Length Control ................................................................................................. 166 Code 39 Set Length 1 .................................................................................................... 167 Code 39 Set Length 2 .................................................................................................... 169 Code 39 Interdigit Ratio ................................................................................................. 171 Code 39 Character Correlation ........................................................................................ 173 Code 39 Stitching ......................................................................................................... 174 Code 32 ............................................................................................................................ 175 Code 32 Enable/Disable ................................................................................................. 175 Code 32 Feature Setting Exceptions ................................................................................. 175 Code 32 Check Character Transmission ............................................................................ 176 Code 32 Start/Stop Character Transmission ...................................................................... 176 Code 128 .......................................................................................................................... 177 Code 128 Enable/Disable ............................................................................................... 177 Expand Code 128 to Code 39 ......................................................................................... 177 Code 128 Check Character Transmission .......................................................................... 178 Code 128 Function Character Transmission ....................................................................... 178 Code 128 Sub-Code Change Transmission ........................................................................ 179 Code 128 Quiet Zones ................................................................................................... 180 Code 128 Minimum Reads .............................................................................................. 181 Code 128 Decoding Level ............................................................................................... 182 Code 128 Length Control ................................................................................................ 184 Code 128 Set Length 1 .................................................................................................. 185 Code 128 Set Length 2 .................................................................................................. 187 Code 128 Character Correlation ...................................................................................... 189 Code 128 Stitching ........................................................................................................ 190 GS1-128 ........................................................................................................................... 191 GS1-128 Enable ............................................................................................................ 191 Interleaved 2 of 5 (I 2 of 5) ................................................................................................. 192 I 2 of 5 Enable/Disable .................................................................................................. 192 I 2 of 5 Check Character Calculation ................................................................................ 193 I 2 of 5 Check Character Transmission ............................................................................. 194 I 2 of 5 Minimum Reads ................................................................................................. 195 2 of 5 Decoding Level .................................................................................................... 196 I 2 of 5 Length Control .................................................................................................. 198 I 2 of 5 Set Length 1 ..................................................................................................... 199 I 2 of 5 Set Length 2 ..................................................................................................... 201 I 2 of 5 Character Correlation ......................................................................................... 203 I 2 of 5 Stitching ........................................................................................................... 204 Datalogic 2 of 5 .................................................................................................................. 205 Datalogic 2 of 5 Enable/Disable ....................................................................................... 205 Datalogic 2 of 5 Check Character Calculation .................................................................... 206 Datalogic 2 of 5 Minimum Reads ..................................................................................... 207 Datalogic 2 of 5 Decoding Level ...................................................................................... 207 Datalogic 2 of 5 Length Control ....................................................................................... 208 Datalogic 2 of 5 Set Length 1 ......................................................................................... 209 Datalogic 2 of 5 Set Length 2 ......................................................................................... 211 Datalogic 2 of 5 Interdigit Maximum Ratio ........................................................................ 213 Datalogic 2 of 5 Character Correlation .............................................................................. 215

Product Reference Guide

5 Datalogic 2 of 5 Stitching ................................................................................................216 Codabar .............................................................................................................................217 Codabar Enable/Disable ..................................................................................................217 Codabar Check Character Calculation ...............................................................................218 Codabar Check Character Transmission ............................................................................219 Codabar Start/Stop Character Transmission ......................................................................219 Codabar Start/Stop Character Set ....................................................................................220 Codabar Start/Stop Character Match ................................................................................221 Codabar Quiet Zones .....................................................................................................222 Codabar Minimum Reads ................................................................................................223 Codabar Decoding Level .................................................................................................224 Codabar Length Control ..................................................................................................226 Codabar Set Length 1 ....................................................................................................227 Codabar Set Length 2 ....................................................................................................229 Codabar Interdigit Ratio .................................................................................................231 Codabar Character Correlation ........................................................................................233 Codabar Stitching ..........................................................................................................234 Code 11 .............................................................................................................................235 Code 11 Enable/Disable ..................................................................................................235 Code 11 Check Character Calculation ...............................................................................236 Code 11 Check Character Transmission ............................................................................237 Code 11 Minimum Reads ................................................................................................238 Code 11 Length Control ..................................................................................................239 Code 11 Set Length 1 ....................................................................................................240 Code 11 Set Length 2 ....................................................................................................242 Code 11 Interdigit Ratio .................................................................................................244 Code 11 Decoding Level .................................................................................................246 Code 11 Character Correlation .........................................................................................248 Code 11 Stitching ..........................................................................................................249 Standard 2 of 5 ..................................................................................................................250 Standard 2 of 5 Enable/Disable .......................................................................................250 Standard 2 of 5 Check Character Calculation .....................................................................251 Standard 2 of 5 Check Character Transmission ..................................................................251 Standard 2 of 5 Minimum Reads ......................................................................................252 Standard 2 of 5 Decoding Level .......................................................................................252 Standard 2 of 5 Length Control ........................................................................................253 Standard 2 of 5 Set Length 1 ..........................................................................................254 Standard 2 of 5 Set Length 2 ..........................................................................................256 Standard 2 of 5 Character Correlation ..............................................................................258 Standard 2 of 5 Stitching ................................................................................................259 ISBT 128 ...........................................................................................................................260 ISBT 128 Enable/Disable ................................................................................................260 ISBT 128 Concatenation .................................................................................................260 ISBT 128 Force Concatenation .........................................................................................261 ISBT 128 Advanced Concatenation Options .......................................................................261 Code 4 ..............................................................................................................................262 Code 4 Enable/Disable ...................................................................................................262 Code 4 Check Character Transmission ..............................................................................263 Code 4 Hex to Decimal Conversion ...................................................................................263 Code 5 ..............................................................................................................................264 Code 5 Enable/Disable ...................................................................................................264 Code 5 Check Character Transmission ..............................................................................265 Code 5 Hex to Decimal Conversion ...................................................................................265 Code 4 and Code 5 Common Configuration Items ....................................................................266 Code 4 and 5 Decoding Level ..........................................................................................266 Code 4 and Code 5 Minimum Reads .................................................................................268 Follett 2 of 5 ......................................................................................................................269 Follett 2 of 5 Enable/Disable ...........................................................................................269

PowerScan® PD7100 Corded

Appendix A. Technical Specifications ..................................................................................... 271 Standard Cable Pinouts ....................................................................................................... 273 Appendix B. Standard Defaults .............................................................................................. 275 Default Exceptions .............................................................................................................. 284 Appendix C. LED and Beeper Indications ............................................................................... 287 LED and Beeper Indications ................................................................................................. 288 Error Codes ....................................................................................................................... 289 Appendix D. Sample Barcodes ............................................................................................... 291 UPC-A .................................................................................................................... 291 Interleaved 2 of 5 ........................................................................................................... 291 Codabar ....................................................................................................................... 292 Code 11 ....................................................................................................................... 292 GS1 DataBar (RSS) ............................................................................................................ 293 GS1 DataBar-14 ........................................................................................................... 293 Appendix E. Keypad ............................................................................................................... 295 Appendix F. Scancode Tables................................................................................................. 299 Control Character Emulation ................................................................................................ 299 Interface Type PC AT PS/2 or USB-Keyboard .......................................................................... 300 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode ................................................. 302 Digital Interface ................................................................................................................. 304 IBM31xx 102-key .............................................................................................................. 306 IBM XT .............................................................................................................................. 308 Microsoft Windows Codepage 1252 ....................................................................................... 310 Index ..................................................................................................................... 313

Product Reference Guide

1 Chapter 1 Introduction About this Guide This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual. Typically, units are factory-programmed for the most common terminal and communi- cations settings. If you need to modify any programmable settings, custom configuration can be accomplished by scanning the programming barcodes within this guide. Programming can alternatively be performed using the Datalogic Aladdin™ Configura- tion application which is downloadable from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration us- ing a PC. It communicates to the device using a serial or USB cable and can also create configuration barcodes to print. Manual Overview Chapter 1, Introduction provides a product overview, unpacking instructions, and cable connection information. Chapter 2, Getting Started presents information about unpacking and setting up the reader. Chapter 3, Interfaces consists of interface configuration barcodes and details. Chapter 4, General Features includes programming barcodes for selecting common features for the reader and general use barcodes to customize how the data is transmitted to the host device. Chapter 5, RS-232 ONLY Interface supplies information about setting up the reader for RS-232 operation. Chapter 6, RS-232/USB-Com Interfaces features information about options involving both the RS-232 and USB-Com interfaces. Chapter 7, Keyboard Interface discusses how to set up the reader for Keyboard Wedge operation. Chapter 8, USB-OEM Interface explains how to set the reader up for USB operation. Chapter 9, IBM 46XX Interface is a resource for setting up an IBM interface. Chapter 10, Data Editing offers advanced configuration options for customization of scanned data output.

PowerScan® PD7100 Corded

Chapter 11, Symbologies defines options for all symbologies and provides the program- ming barcodes necessary for configuring these features. Appendix A, Technical Specifications lists physical and performance characteristics, as well as environmental and regulatory specifications. It also provides standard cable pin- outs. Appendix B, Standard Defaults references common factory default settings for reader features and options. Appendix C, LED and Beeper Indications supplies tables containing descriptions of the functions and behaviors of the reader’s LED and Beeper indicators. Appendix D, Sample Barcodes offers sample barcodes of several common symbologies. Appendix E, Keypad includes numeric barcodes to be scanned for certain parameter set- tings. Appendix F, Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces. Manual Conventions The following conventions are used in this document: The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: References Current versions of the Product Reference Guide (PRG), Quick Reference Guide (QRG), the Datalogic Aladdin™ Configuration application, and any other manuals, in- struction sheets and utilities for this product can be downloaded from the website listed on the back cover of this manual. Alternatively, printed copies or product support CDs can be purchased through your Datalogic reseller. NOTE Notes contain information necessary for properly diagnosing, repair- ing and operating the reader. CAUTION The CAUTION symbol advises you of actions that could damage equipment or property.

Product Reference Guide

3 Technical Support Datalogic Website Support The Datalogic website (www.scanning.datalogic.com) is the complete source for technical support and information for Datalogic products. The site offers product support, prod- uct registration, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair. Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individualized assistance. Telephone Technical Support If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information.

Product Reference Guide

5 Chapter 2 Getting Started About the Reader Advancements in the LED technology used in this reader significantly improve the illumination of the target field of view, resulting in higher scan efficiency. Whether used in Single Trigger or Continuous Mode, the ergonomic design of the reader will help to promote comfortable han- dling during extended periods of use. See Interface Selection on page 11 for a listing and descriptions of available interface sets by model type. Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Technical Support on page 3. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.

PowerScan® PD7100 Corded

Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host: 1. Install the Interface Cable 2. Select the Interface Type 3. Configure Interface Settings (only if not using factory settings for that interface) 4. Configure Other Features (if modifications are needed from factory settings) Install the Interface Cable The reader cable connection is secured using the “clamshell” retainer referenced in the enlarged area of Figure 1. Fit and clamp the retainer over the cable connector as shown in the illustra- tion, then fully seat the cable assembly into the reader, aligning both the connector and the retainer boss with their respective openings. Secure the captive screws. RS-232 Serial Connection — Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in Figure 1. If the terminal will not support POT (Power Off the Terminal) to supply reader power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable con- nector and the AC Adapter plug into a standard power outlet. Figure 1. Connecting the Interface Cable/RS-232 Connection Captive Screws Retainer Boss Cable Connector

Setting Up the Reader

Product Reference Guide 7 Other connection types are described below and illustrated in Figure 2. USB Connection — Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 2. IBM Connection — Connect the reader to the IBM port on the terminal/PC using the cor- rect IBM cable. Reference Figure 2. Keyboard Wedge Connection — The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 2. Figure 2. Other Interface Connections Programming The reader is factory-configured with a set of default features standard. After scanning the inter- face barcode from the Interfaces section, you can select other options and customize your reader through use of the instructions and programming barcodes available in the corresponding features section for your interface and also the Data Editing and Symbologies chapters of this manual. NOTE Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect the reader remain the same. U S B I B M K e y b o ar d W e d g e or... or...

PowerScan® PD7100 Corded

Using the Programming Barcodes This manual contains feature descriptions and barcodes which allow you to reconfigure your reader. Some programming barcode labels, like the Standard Product Default Settings on page 9, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the reader to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT barcode once to enterProgramming Mode. Once the reader is in Programming Mode, you can scan a number of parameter settings before scanning the ENTER/EXIT barcode a second time, which will then accept your changes, exit Program- ming Mode and return the reader to normal operation. Select the Interface Type Upon completing the physical connection between the reader and its host, proceed directly to Interfaces on page 11 for information and programming for the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate bar- code in that section to select your system’s correct interface type. Configure Interface Settings If after scanning the interface barcode from the Interfaces section, your installation requires you to select options to further customize your reader, turn to the appropriate section for your interface type as listed below: • RS-232 ONLY Interface, starting on page 47 • Keyboard Interface, starting on page 73 • USB-OEM Interface, starting on page 87 • IBM 46XX Interface, starting on page 89 Configure Other Features If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require: General Features — General Features includes programming for scanning, beeper and LED indicators and other such universal settings. Symbologies — Includes options concerning the barcode label types (symbologies). These set- tings allow you to enable/disable symbologies, set label lengths, require check digit, etc. NOTE There are some exceptions to the typical programming sequence described above. Please read the description and setting instruc- tions carefully when configuring each given programmable feature.

Resetting the Standard Product Defaults

Product Reference Guide 9 Resetting the Standard Product Defaults If you aren’t sure what programming options are in your reader, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings barcode below. This will copy the factory configuration for the currently active interface to the current configuration. The programming section lists the factory default settings for each of the menu commands (indicated by shaded blocks and bold text) on the following pages. NOTE Factory defaults are based on the interface type. Configure the reader for the correct interface before scanning this label. Standard Product Default Settings

Product Reference Guide

11 Chapter 3 Interfaces Interface Selection Each reader model will support one of the following sets of host interfaces: General Purpose Models (5 volt supply) RS-232 RS-232 OPOS USB Keyboard Wedge Retail Point of Sale Models (4 to 14 volt supply) RS-232 RS-232 OPOS USB IBM 46XX Configuring the Interface Scan the programming barcode from this section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corre- sponding chapter in this manual (also listed in Table 1) to configure any desired settings and features associated with that interface. NOTE Unlike some other programming features and options, interface selections require that you scan only one programming barcode label. DO NOT scan an ENTER/EXIT barcode prior to scanning an interface selection barcode. Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold it for five seconds. The scanner will change to a state that allows programming with bar- codes.

PowerScan® PD7100 Corded

Table 1. Available Interfaces RS-232 FEATURES RS-232 standard interface Select RS232-STD Set RS-232 Interface Features starting on page 47 Select RS232-WN RS-232 Wincor-Nixdorf RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS Select USB-COM-STDa USB Com to simulate RS-232 standard interface IBM FEATURES Select IBM-P5B IBM-46xx Port 5B reader interface Set IBM Interface Features starting on page 89 IBM-46xx Port 9B reader interface Select IBM-P9B USB-OEM FEATURES Select USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS) Set USB-OEM Interface Features starting on page 87 a. Download the correct USB Com driver from www.datalogic.com

Configuring the Interface

Product Reference Guide 13 KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT Set KEYBOARD WEDGE Interface Features starting on page 73 Select KBD-AT-NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Select KBD-AT-ALT Select KBD-AT-ALT-NK Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard PC/XT w/Standard Key Encoding Select KBD-XT Select KBD-IBM-3153 Keyboard Wedge for IBM Terminal 3153

PowerScan® PD7100 Corded

KEYBOARD — cont. FEATURES Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M Set KEYBOARD WEDGE Interface Features starting on page 73 Select KBD-IBM-MB Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT Select USB Keyboard USB Keyboard with standard key encoding USB Keyboard with alternate key encoding Select USB Alternate Keyboard Select USB-KBD-APPLE USB Keyboard for Apple computers

Global Interface Features

Product Reference Guide 15 Global Interface Features The following interface features are configurable by all interface types. To set features specific to your interface, turn to that section of this manual: • RS-232 ONLY Interface on page 47 • Keyboard Interface on page 73 • USB-OEM Interface on page 87 • IBM 46XX Interface on page 89 Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: • service mode • flash programming mode • keeping the interface active • transmission of labels. ENTER/EXIT PROGRAMMING MODE Host Commands = Obey Host Commands = Ignore DEFAULT

PowerScan® PD7100 Corded

USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode. ENTER/EXIT PROGRAMMING MODE USB Suspend Mode = Disable USB Suspend Mode = Enable DEFAULT

Product Reference Guide

17 Chapter 4 General Features Double Read Timeout To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Double Read Timeout, the second read of the label will be ignored. Double Read Timeout does not apply to scan modes that re- quire a trigger pull for each label that is read. ENTER/EXIT PROGRAMMING MODE Double Read Timeout = 0.1 Second Double Read Timeout = 0.2 Second Double Read Timeout = 0.3 Second Double Read Timeout = 0.4 Second DEFAULT

PowerScan® PD7100 Corded

Double Read Timeout — continued ENTER/EXIT PROGRAMMING MODE Double Read Timeout = 0.5 Second Double Read Timeout = 0.6 Second Double Read Timeout = 0.7 Second Double Read Timeout = 0.8 Second Double Read Timeout = 0.9 Second Double Read Timeout = 1 Second

Label Gone Timeout

Product Reference Guide 19 Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 millisec- onds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING. 5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table2 for some examples of how to set this feature. Table 2. Timeout Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 50ms 150ms 1800ms (1.8 sec.) 2550ms (2.55 sec.) 2 Divide by 10 (and pad with leading zeroes) 005 015 180 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT LABEL GONE TIMEOUT SETTING 5 Scan Three Characters From Appendix E, Keypad ‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘5’ ‘1’, ‘8’ and ‘0’ ‘‘2’, ‘5’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Label Gone Timeout — cont. ENTER/EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 016 = Timeout of 160 ms

Sleep Mode Timeout

Product Reference Guide 21 Sleep Mode Timeout Specifies the timeout value for the reader to enter low power Sleep Mode. ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout = Disable Sleep Mode Timeout = 500ms Sleep Mode Timeout = 1 Second Sleep Mode Timeout = 2 Seconds Sleep Mode Timeout = 3 Seconds Sleep Mode Timeout = 4 Seconds DEFAULT

PowerScan® PD7100 Corded

Sleep Mode Timeout — continued ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout = 5 Seconds Sleep Mode Timeout = 6 Seconds Sleep Mode Timeout = 7 Seconds Sleep Mode Timeout = 8 Seconds Sleep Mode Timeout = 9 Seconds Sleep Mode Timeout = 9.9 Seconds (9,900ms max.)

LED and Beeper Indicators

Product Reference Guide 23 LED and Beeper Indicators Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. ENTER/EXIT PROGRAMMING MODE Power On Alert = Disable (No Audible Indication) Power On Alert = Four Beeps DEFAULT

PowerScan® PD7100 Corded

Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active NOTE This option, which uses CTS, is only valid for RS-232 interfaces. ENTER/EXIT PROGRAMMING MODE Indicate Good Read = After Decode Indicate Good Read = After Transmit Indicate Good Read = After CTS Goes Inactive, Then Active DEFAULT

LED and Beeper Indicators

Product Reference Guide 25 Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. ENTER/EXIT PROGRAMMING MODE Good Read Beep Type = Mono Good Read Beep Type = Bitonal DEFAULT

PowerScan® PD7100 Corded

Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, se- lectable from the list below. (Controls the beeper’s pitch/tone.) Good Read Beep Length Specifies the duration of a good read beep. ENTER/EXIT PROGRAMMING MODE Good Read Beep Frequency = Low Good Read Beep Frequency = Medium Good Read Beep Frequency = High DEFAULT ENTER/EXIT PROGRAMMING MODE Good Read Beep Length = 60 msec

LED and Beeper Indicators

Product Reference Guide 27 Good Read Beep Length — continued ENTER/EXIT PROGRAMMING MODE Good Read Beep Length = 80 msec Good Read Beep Length = 100 msec Good Read Beep Length = 120 msec Good Read Beep Length = 140 msec Good Read Beep Length = 160 msec Good Read Beep Length = 180 msec Good Read Beep Length = 200 msec DEFAULT

PowerScan® PD7100 Corded

Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. ENTER/EXIT PROGRAMMING MODE Good Read Beep Volume = Beeper Off Good Read Beep Volume = Low Good Read Beep Volume = Medium Good Read Beep Volume = High DEFAULT

LED and Beeper Indicators

Product Reference Guide 29 Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 10ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad represent- ing the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table3 for some examples of how to set this feature. Table 3. Good Read LED Duration Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting Good Read LED stays on until next trigger pull (00) 20ms 150ms 2550ms (2.55 sec.) 2 Divide by 10 (and pad with leading zeroes) 000 002 015 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT LABEL GONE TIMEOUT SETTING 5 Scan Three Characters From Appendix E, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘2’, ‘5’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Good Read LED Duration — cont. ENTER/EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 020 = Good Read LED stays on for 2 seconds. NOTE Indicators are dimmed during sleep.

Product Reference Guide

31 Scanning Features Scan Mode Selects the scan operating mode for the reader. Selections are: Trigger Single — When the trigger is pulled, scanning is activated until one of the fol- lowing occurs: - Scanning Active Time has elapsed - a label has been read - the trigger is released This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum Scanning Active Time has elapsed. Trigger Hold Multiple — When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Trigger Pulse Multiple — When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Flashing — The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the reader reads con- tinuously, when Flash is OFF scanning is deactivated. Always On — No trigger pull is required to read a barcode. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Stand Mode — No trigger pull is required to read a barcode. Scanning is turned on au- tomatically when an item is placed in reader’s field of view. If the trigger is pulled, the reader acts as if it in single read mode. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Trigger Object Sense — This mode is similar to Stand Mode, except that a trigger pull is required to activate the decoder. 1. Controlled by Flash On Time.

PowerScan® PD7100 Corded

Scan Mode — continued ENTER/EXIT PROGRAMMING MODE Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode Scan Mode = Trigger Object Sense DEFAULT

Product Reference Guide

33 Stand Mode Triggered Timeout This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode. NOTE This timeout is only used when the Scan Mode is configured as Stand Mode. ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout = 0.5 Seconds Stand Mode Triggered Timeout = 1.5 Seconds Stand Mode Triggered Timeout = 2 Seconds Stand Mode Triggered Timeout = 3 Seconds Stand Mode Triggered Timeout = 4 Seconds DEFAULT

PowerScan® PD7100 Corded

Stand Mode Triggered Timeout — continued ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout = 6 Seconds Stand Mode Triggered Timeout = 8 Seconds Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull

Product Reference Guide

35 Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre- ments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table4 for some examples of how to set this feature. Table 4. Scanning Active Time Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.) 2 Pad leading zero(es) 001 090 180 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT SCANNING ACTIVE TIME SETTING 5 Scan Three Characters From Appendix E, Keypad ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Scanning Active Time — cont. ENTER/EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 005 = Scanning is active for 5 Seconds

Flash On Time

Product Reference Guide 37 Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT FLASH ON TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad represent- ing the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table5 for some examples of how to set this feature. Table 5. Flash On Time Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.) 2 Divide by 100 (and pad with leading zeroes to yield two digits) 05 10 52 99 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT FLASH OFF TIME SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Flash On Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 10 = Flash is ON for 1 Second

Flash Off Time

Product Reference Guide 39 Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT FLASH OFF TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that repre- sent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table6 for some examples of how to set this feature. Table 6. Flash Off Time Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.) 2 Divide by 100 (and pad with leading zeroes to yield two digits) 05 10 52 99 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT FLASH OFF TIME SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Flash Off Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 06 = Flash is OFF for 600ms

Stand Mode Sensitivity

Product Reference Guide 41 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. ENTER/EXIT PROGRAMMING MODE Stand Mode Sensitivity = Low Stand Mode Sensitivity = Medium Stand Mode Sensitivity = High DEFAULT

PowerScan® PD7100 Corded

Laser Pointer Control Specifies the amount of time that the laser pointer is turned on preliminary to scanning. When the trigger is pressed in Trigger Single Mode, the laser pointer will be activated for the time period configured by this feature. Immediately following this, the reader will start scanning. NOTE The Laser Pointer is a value-added option which might not have been included when your reader was ordered. ENTER/EXIT PROGRAMMING MODE Laser Pointer Control = 0 msec (No preliminary pointer — i.e. start scanning immediately after trigger) Laser Pointer Control = 100 msec Laser Pointer Control = 200 msec Laser Pointer Control = 300 msec Laser Pointer Control = 400 msec Laser Pointer Control = 500 msec DEFAULT

Laser Pointer Period

Product Reference Guide 43 Laser Pointer Period This option specifies the period of the laser pointer blink during scanning. The laser pointer will be activated for the time specified by Laser Pointer Control. then start blinking OFF then ON at 50% duty cycle for the duration set by Laser Pointer Period. ENTER/EXIT PROGRAMMING MODE Laser Pointer Period = Disable Laser Pointer Period = 500 ms Laser Pointer Period = 1 Second (1,000 ms) Laser Pointer Period = 1.5 Seconds (1,500 ms) Laser Pointer Period = 2 Seconds (2,000 ms) DEFAULT

PowerScan® PD7100 Corded

Laser Pointer Period — cont. Laser Pointer Period = 2.5 Seconds (2,500 ms) Laser Pointer Period = 3 Seconds (3,000 ms) Laser Pointer Period = 3.5 Seconds (3,500 ms) Laser Pointer Period = 4 Seconds (4,000 ms) Laser Pointer Period = 4.5 Seconds (4,500 ms) Laser Pointer Period = 5 Seconds (5,000 ms)

Green Spot Duration

Product Reference Guide 45 Green Spot Duration Specifies the duration of the good read pointer beam after a good read. ENTER/EXIT PROGRAMMING MODE Green Spot Duration = Disable (Green Spot is Off) Green Spot Duration = Short (300 msec) Green Spot Duration = Medium (500 msec) Green Spot Duration = Long (800 msec) DEFAULT

Product Reference Guide

47 Chapter 5 RS-232 ONLY Interface Introduction Use the programming barcodes in this chapter if modifications to the standard RS- 232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 6, RS-232/USB-Com Interfaces. RS-232 Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings. Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate set- ting, data may not reach the host correctly. ENTER/EXIT PROGRAMMING MODE Baud Rate = 1200 Baud Rate = 2400 Baud Rate = 4800

RS-232 ONLY Interface

48 PowerScan® PD7100 Corded Baud Rate — continued ENTER/EXIT PROGRAMMING MODE Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 Baud Rate = 115,200 DEFAULT

Product Reference Guide

49 Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. ENTER/EXIT PROGRAMMING MODE 7 Data Bits 8 Data Bits DEFAULT

RS-232 ONLY Interface

50 PowerScan® PD7100 Corded Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements. ENTER/EXIT PROGRAMMING MODE 1 Stop Bit 2 Stop Bits DEFAULT

Product Reference Guide

51 Parity This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select None when no parity bit is required. • Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. • Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character. ENTER/EXIT PROGRAMMING MODE Parity = None Parity = Even Parity = Odd DEFAULT

RS-232 ONLY Interface

52 PowerScan® PD7100 Corded Handshaking Control The data interface consists of an RS-232 port designed to operate either with or with- out the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options: • RTS — RTS is asserted during transmissions. CTS is ignored. • RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions. • RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions. • RTS On/CTS — RTS is always asserted. CTS gates transmissions. • RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner. ENTER/EXIT PROGRAMMING MODE Handshaking Control = RTS Handshaking Control = RTS/CTS Handshaking Control = RTS/XON/XOFF Handshaking Control = RTS On/CTS Handshaking Control = RTS/CTS Scan Control DEFAULT

Product Reference Guide

53 Chapter 6 RS-232/USB-Com Interfaces Introduction The programming barcodes in this chapter allow modifications to the standard RS- 232 and USB-Com interfaces. Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings.

PowerScan® PD7100 Corded

Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT INTERCHARACTER DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 7 for some examples of how to set this fea- ture. Table 7. Intercharacter Delay Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 50ms 150ms 600ms 850ms 2 Divide by 10 (and pad with leading zeroes to yield two-digits) 05 15 60 85 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCHARACTER DELAY SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘5’ ‘5’ and ‘0’ 0’ and ‘0’ ‘8’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

55 Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 00 = No Intercharacter Delay

PowerScan® PD7100 Corded

Beep On ASCII BEL When this parameter is enabled, the reader issues a beep when a character is detected on the RS-232 serial line. is issued to gain a user's attention to an illegal entry or other important event. Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command. ENTER/EXIT PROGRAMMING MODE Beep On ASCII BEL = Disable Beep On ASCII BEL = Enable DEFAULT ENTER/EXIT PROGRAMMING MODE Beep On Not On File = Disable Beep On Not On File = Enable DEFAULT

ACK NAK Options

Product Reference Guide 57 ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK pro- tocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent. • Enable for host-command acknowledge — The reader will respond with ACK/ NAK when the host sends a command. • Enable for label transmission and host-command acknowledge ENTER/EXIT PROGRAMMING MODE ACK/NAK Protocol = Disable ACK/NAK ACK/NAK Protocol = Enable for label transmission ACK/NAK Protocol = Enable for host-command acknowledge ACK/NAK Protocol = Enable for label transmission and host-com- mand acknowledge DEFAULT

PowerScan® PD7100 Corded

ACK Character This setting specifies an ASCII character or hex value to be used as the ACK charac- ter. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equiv- alent for the desired character/value. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT ACK CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 8 for some examples of how to set this fea- ture. Table 8. ACK Character Setting Examples NOTE Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. STEP ACTION EXAMPLES 1 Desired Character/Value ACK $ @ > 2 Hex equivalent 0x06 0x24 0x40 0x3E 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK CHARACTER SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ 6 Scan ENTER/EXIT PROGRAMMING MODE

ACK NAK Options

Product Reference Guide 59 ACK Character — cont. ENTER/EXIT PROGRAMMING MODE Select ACK Character Setting DEFAULT 0x06 ‘ACK’ Character

PowerScan® PD7100 Corded

NAK Character This setting specifies an ASCII character or hex value to be used as the NAK charac- ter. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equiv- alent for the desired character/value. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT NAK CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 9 for some examples of how to set this fea- ture. Table 9. NAK Character Setting Examples NOTE Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. STEP ACTION EXAMPLES 1 Desired Character/Value NAK $ @ > 2 Hex equivalent 0x15 0x24 0x40 0x3E 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK CHARACTER SETTING 5 Scan Two Characters From Appendix E, Keypad ‘1’ and ‘5’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ 6 Scan ENTER/EXIT PROGRAMMING MODE

ACK NAK Options

Product Reference Guide 61 NAK Character — cont. ENTER/EXIT PROGRAMMING MODE Select NAK Character Setting DEFAULT 0x15 ‘NAK’ Character

PowerScan® PD7100 Corded

ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 millisec- onds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 10 for some examples of how to set this feature. Table 10. ACK NAK Timeout Value Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 200ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 15,000ms (1 sec.) 2 Divide by 200 01 05 26 75 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK NAK TIMEOUT VALUE SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘1’ ‘0’ and ‘5’ ‘2’ and ‘6’ ‘7’ and ‘5’ 7 Scan ENTER/EXIT PROGRAMMING MODE

ACK NAK Options

Product Reference Guide 63 ACK NAK Timeout Value — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms

PowerScan® PD7100 Corded

ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that represent the number which was determined in the steps above. You will hear a two-beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 11 for some examples of how to set this feature. Table 11. ACK NAK Retry Count Setting Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting Disable Retry Count 3 Retries 54 Retries Unlimited Retries 2 Pad with leading zero(es) 000 003 054 255 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT ACK NAK RETRY COUNT SETTING 5 Scan Three Characters From Appendix E, Keypad ‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘3’ ‘0’, ‘5’ and ‘4’ ‘2’, ‘5’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

ACK NAK Options

Product Reference Guide 65 ACK NAK Retry Count — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 003 = 3 Retries

PowerScan® PD7100 Corded

ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host. Options are: • Ignore errors detected • Process error as valid ACK character • Process error as valid NAK character ENTER/EXIT PROGRAMMING MODE ACK NAK Error Handling = Ignore Errors Detected ACK NAK Error Handling = Process Error as Valid ACK Character ACK NAK Error Handling = Process Error as Valid NAK Character DEFAULT

Indicate Transmission Failure

Product Reference Guide 67 Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode. ENTER/EXIT PROGRAMMING MODE Indicate Transmission Failure = Disable Indication Indicate Transmission Failure = Enable Indication DEFAULT

PowerScan® PD7100 Corded

Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. To set the value: 1. Determine the desired character or value. A setting of 0xFF indicates the the Dis- able Character is not used (not available). 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equiv- alent for the desired character/value. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT DISABLE CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 12 for some examples of how to set this feature. Table 12. Disable Character Setting Examples NOTE Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. STEP ACTION EXAMPLES 1 Desired character/value ‘d’ ‘}’ ‘D’ Disable Command Not Used 2 Hex equivalent 0x64 0x7D 0x44 0xFF 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT DISABLE CHARACTER VALUE SETTING 5 Scan Two Characters From Appendix E, Keypad ‘6’ and ‘4’ ‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ AND ‘F’ 6 Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

69 Disable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Disable Character Setting DEFAULT 0x44 = Disable Character is ‘D’

PowerScan® PD7100 Corded

Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: Determine the desired character or value. A setting of 0xFF indicates the the Enable Character is not used (not available). 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equiv- alent for the desired character/value. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT ENABLE CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 2 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 13 for some examples of how to set this feature. Table 13. Enable Character Setting Examples NOTE Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. STEP ACTION EXAMPLES 1 Desired character/value ‘e’ ‘}’ ‘E’ Enable Command Not Used 2 Hex equivalent 0x65 0x7D 0x45 0xFF 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT DISABLE CHARACTER VALUE SETTING 5 Scan Two Characters From Appendix E, Keypad ‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’ 6 Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

71 Enable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Enable Character Setting DEFAULT 0x45 = Enable Character is ‘E’

Product Reference Guide

73 Chapter 7 Keyboard Interface Introduction Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings. Scancode Tables Information about control character emulation which applies to keyboard interfaces is listed in Appendix F, Scancode Tables.

PowerScan® PD7100 Corded

Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. • USB Keyboard (without alternate key encoding) • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding • Keyboard Wedge for IBM AT PS2 with standard key encoding but without exter- nal keyboard • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 without Alternate Key • Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY the following Country Modes: U.S., Belgium, Brit- ain, France, Germany, Italy, Spain, Sweden. ENTER/EXIT PROGRAMMING MODE Country Mode = U.S. Country Mode = Belgium Country Mode = Britain Country Mode = Croatia Supports only the interfaces listed in theCountry Mode feature description. Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Czechoslovakia DEFAULT

Product Reference Guide

75 Country Mode — continued ENTER/EXIT PROGRAMMING MODE Country Mode = Denmark Supports only the interfaces listed in theCountry Mode feature description. Country Mode = France Country Mode = Germany Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Hungary Country Mode = Italy Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Japanese 106-key Country Mode = Norway Supports only the interfaces listed in theCountry Mode feature description.

PowerScan® PD7100 Corded

Country Mode — continued ENTER/EXIT PROGRAMMING MODE Country Mode = Poland Supports only the interfaces listed in theCountry Mode feature description. Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Portugal Country Mode = Romania Supports only the interfaces listed in theCountry Mode feature description. Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Slovakia Country Mode = Spain Country Mode = Sweden Country Mode = Switzerland Supports only the interfaces listed in theCountry Mode feature description.

Caps Lock State

Product Reference Guide 77 Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard. ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable DEFAULT ENTER/EXIT PROGRAMMING MODE Numlock = Numlock key unchanged Numlock = Numlock key toggled DEFAULT

PowerScan® PD7100 Corded

Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the host. Ref- erence Appendix F, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 — Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1. Control Character 01 — Characters from 00 to 0x1F are sent as control character Ctrl+Capital Key, special keys are located from 0x80 to 0xA1. Control Character 02 — Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252 — see Microsoft Windows Codepage 1252 on page 310). ENTER/EXIT PROGRAMMING MODE Wedge Send Control Characters = 00 Wedge Send Control Characters = 01 Wedge Send Control Characters = 02 DEFAULT

Wedge Quiet Interval

Product Reference Guide 79 Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the read- er breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure to set the Wedge Quiet Interval. See Table 14 for some examples of how to set this feature. Table 14. Timeout Setting Examples NOTE This feature applies ONLY to the Keyboard Wedge interface. NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 10ms 150ms 600ms 850ms 2 Divide by 10 (and pad with leading zeroes) 01 15 60 85 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT WEDGE QUIET INTERVAL SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Wedge Quiet Interval — cont. ENTER/EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 10 = Quiet Interval of 100 ms

Product Reference Guide

81 Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT INTERCHARACTER DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 14 for some examples of how to set this feature. Table 15. Intercharacter Delay Setting Examples NOTE This feature applies ONLY to the Keyboard Wedge interface. NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting 50ms 150ms 600ms 850ms 2 Divide by 10 (and pad with leading zeroes to yield two-digits) 05 15 60 85 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCHARACTER DELAY SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘5’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’ 6 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 00 = No Intercharacter Delay

Product Reference Guide

83 Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT INTERCODE DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See Table 16 for some examples of how to set this feature. Table 16. Wedge Intercode Delay Examples NOTE If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. STEP ACTION EXAMPLES 1 Desired Setting No Delay 5 Seconds 60 Seconds 99 Seconds 2 Pad with leading zero(es) 00 05 60 99 3 Scan ENTER/EXIT PROGRAMMING MODE 4 Scan SELECT INTERCODE DELAY SETTING 5 Scan Two Characters From Appendix E, Keypad ‘0’ and ‘0’ ‘0’ and ‘5’ ‘6’ and ‘0’ ‘9’ AND ‘9’ 7 Scan ENTER/EXIT PROGRAMMING MODE

PowerScan® PD7100 Corded

Intercode Delay — cont. ENTER/EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 00 = No Wedge Intercode Delay

USB Keyboard Speed

Product Reference Guide 85 USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. NOTE This feature applies ONLY to the USB Keyboard interface. ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed = 1ms USB Keyboard Speed = 2ms USB Keyboard Speed = 3ms USB Keyboard Speed = 4ms USB Keyboard Speed = 5ms DEFAULT

PowerScan® PD7100 Corded

USB Keyboard Speed — continued ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed = 6ms USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms

Product Reference Guide

87 Chapter 8 USB-OEM Interface Introduction Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and Chapter 9, IBM 46XX Interface to specifically configure for the USB-OEM interface. Other USB interfaces are included in the approprite chapter for their host type. Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings.

PowerScan® PD7100 Corded

USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have con- nected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner NOTE It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system. ENTER/EXIT PROGRAMMING MODE USB-OEM Device Usage = Table Top Scanner USB-OEM Device Usage = Handheld Scanner DEFAULT

Product Reference Guide

89 Chapter 9 IBM 46XX Interface Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. IBM Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings.

IBM 46XX Interface

90 PowerScan® PD7100 Corded 46xx Number of Host Resets Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The con- figurable range for this feature is 1 to 15 resets. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 1 46xx Number of Host Resets = 2 46xx Number of Host Resets = 3 46xx Number of Host Resets = 4 46xx Number of Host Resets = 5 46xx Number of Host Resets = 6 DEFAULT

46xx Number of Host Resets

Product Reference Guide 91 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 7 46xx Number of Host Resets = 8 46xx Number of Host Resets = 9 46xx Number of Host Resets = 10 46xx Number of Host Resets = 11 46xx Number of Host Resets = 12

IBM 46XX Interface

92 PowerScan® PD7100 Corded 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 13 46xx Number of Host Resets = 14 46xx Number of Host Resets = 15

Other Barcode Reader Manuals