Page | 21

MAINTENANCE Inspecting Gaskets An airtight seal at the door opening is crucial to proper stove performance.  Any air leakage at this area can cause an over‐fire situation and is therefore a serious safety threat.  Because of this, gaskets should always be maintained in good condition.  Gasket tightness can be checked using the “dollar‐bill” method:  Place a dollar bill between the gasket and the stove body (at the location where the gasket meets the stove).  Tighten the latching mechanism down and ...

Page | 15

FLOOR PROTECTION  This wood stove requires a non‐combustible floor protector if the stove is to be installed on a combustible floor.  If the floor the stove is to be installed on is already non‐combustible (i.e. a concrete floor in a basement), no floor protection is needed (although a decorative floor protector can still be used for aesthetic reasons).  When using any floor protector, consider that this stove is not only heavy but will induce heating and cooling cycles on the floor protector which� ...

Page | 13

INSTALLATION Approved Venting Method 3: Internal or External Masonry Chimney System Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local codes. Chimney Connector (Single or Double Wall) 3.0 ft. 2.0 ft. 10 ft. The 10‐3‐2 Rule: The chimney system must terminate 3.0 ft. above the point where its centerline passes through the roof AND the ...

Page | 22

REPLACING COMPONENTS Glass This unit has a ceramic glass panel (Part No. AC‐G40) in the viewing door; self adhesive window gasket is included with replacement windows purchased directly from England’s Stove Works. Never replace ceramic glass with tempered or any other type of glass and never operate this unit with cracked or broken glass.  Glass Size: 14.5 in. (368.3 mm) x 10.75 in. (273.05 mm)  Glass Type: 5mm Ceramic Glass (Keralite Pyroceram)  Glass Manufacturer: Eurokera Glass Precautions 1. Never re ...

Page | 19

OPERATION Additional Safety Guidelines  The installation of smoke detectors is highly recommended when installing this or any other solid fuel burning appliance.  Smoke detectors should be located near or in every room of the home, particularly sleeping rooms.  A smoke detector can be installed in the same room as this cordwood burning unit; installing the smoke detector too close to the unit can lead to nuisance alarms due to slight wisps of smoke emitted during the fire starting or reloading process. � ...

Page | 19

OPERATION Additional Safety Guidelines  The installation of smoke detectors is highly recommended when installing this or any other solid fuel burning appliance.  Smoke detectors should be located near or in every room of the home, particularly sleeping rooms.  A smoke detector can be installed in the same room as this cordwood burning unit; installing the smoke detector too close to the unit can lead to nuisance alarms due to slight wisps of smoke emitted during the fire starting or reloading process. � ...

Page | 12

INSTALLATION Approved Venting Method 2: Through the Ceiling Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local codes. Ceiling Support Box Storm Collar Termination Cap Roof Flashing Class A Chimney System Chimney Connector (Single or Double Wall) 3.0 ft. 2.0 ft. 10 ft. The 10‐3‐2 Rule: The chimney system must terminate 3.0 ft. above  ...

England's Stove Works 17?VL user guide recommended for: 50-SNC13, 25-EPI, 30-NC, 25-PDVC, 10-CDV.

⚠️ Download Safety

The Cooktop Installation & operation manual (30 pages) is completely safe to download (last scan date: 04/05/2026).