EXCELL PRECISION CO., LTD

Dolphin 9903 V 1.1 SME300000041 © Excell Precision Limited 2005. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 1 TABLE OF CONTENTS INSTRUCTION FOR USE............................................................................................................2 PREPARING TO USE THE SCALE.............................................................................................2 CHAPTER 1 FEATURES AND SPACIFICATIONS......................................................................3 1. Features............................................................................................................................3 2. Options..............................................................................................................................3 3. Specifications ....................................................................................................................3 4. Power Supply....................................................................................................................4 CHAPTER 2 DISPLAY.................................................................................................................5 CHAPTER 3 KEYBOARD FUNCTION ........................................................................................6 CHAPTER 4 BASIC FUNCTION OPERATION ...........................................................................7 1. Switch On..........................................................................................................................7 2. Re-Zero.............................................................................................................................7 3. Unit Selection ....................................................................................................................7 4. Tare Function.....................................................................................................................8 5. Net/Gross Weight Conversion...........................................................................................8 6. Simple Counting................................................................................................................9 CHAPTER 5 ADVANCED FUNCTIONS SETTING....................................................................10 1. Function Setting ...............................................................................11 1-1 Auto Backlight Setting .............................................................12 1-2 Auto-off Timer Setting .............................................................13 1-3 Check-Weighing Setting .........................................................14 1-4 Restore to Factory Setting ......................................................15 1-5 Environment Parameter Setting ..............................................16 1-6 Hold Function Setting ..............................................................17 2. External Weight Calibration ...................................................................18 APPENDIX SEVEN-SEGMENT DISPLAY CHARACTERS .......................................................19

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 2 INSTRUCTION FOR USE Thank you for purchasing the 9903 Dolphin II weighing scale of Excell. To enable you to use this scale correctly, we suggest that you read the following instructions carefully. 1. Don’t bump the scale against other items nor load it with heavy weight exceeding its full capacity. 2. Keep it away from high temperature. 3. If the scale is not going to be used for a certain period of time, clean it and store it in a polythene bag. A desiccant may be included. 4. If the scale is not used for a long period of time, recharge it every 3 months so as to ensure a long life of the battery. Fully recharge it before using again. Take care not to keep the scale being charged for too long. 5. Commodities should be placed at the center of the platter when being weighed, and can’t exceed the dimension of the platter. PREPARING TO USE THE SCALE 1. Please locate the scale on a stable, level surface to ensure accurate weight readings. 2. Adjust the four leveling feet to make the balance horizontal. Make sure that the level bubble is in the center of the circle. 3. Keep the scale away from places with strong drafts or excessive temperature fluctuations (e.g. direct sunlight or the air louver of an air conditioner). 4. There should be no weight on the scale when the scale is switched on. 5. Once the scale is switched on, it will go through a LCD display test and then re-zero to be ready for use. 6. Please warm up the scale for 15~20 minutes before operation. 7. Please note when the symbol flashes on the screen, the battery needs to be recharged.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 3 CHAPTER 1 FEATURES AND SPACIFICATIONS 1. Features 2 IP65 Wash down design 2 Auto calibration 2 Large LCD display with LED backlight included 2 Kilogram (kg) and pound (lb) weighing modes 2 Full range tare; Auto zero tracking 2 Adjustable gravity value 2 Simple counting; Gross/Net indication; Hold function; Check mode Lo/Hi/OK 2 Low power indication and auto power off 2 Easily adjusted leveling feet for stability of the scale 2. Options 2 Second display (customer side) 2 DC 6V/1.2 AH Rechargeable battery 2 Stainless steel platter (220 x 190 mm) 3. Specifications Model Capacity Division 9903-3 3 kg (6 lb ) 1 g (0.002 lb) 9903-6 6 kg (12 lb) 2 g (0.005 lb) 9903-15 15 kg (30 lb) 5 g (0.01 lb) 9903-30 30 kg (60 lb) 10 g (0.02 lb) Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F) Power Source: AC 110V/230V (±10%) or 4 x UM-1 1.5V dry batteries (not included) Dimensions: 242 x 130 x 285 mm ( W x H x D ) Platter Size: 218 x 188 mm (Plastic platter); 220 x 190 mm (Steel platter) Display: LCD, 6 Digits. 25 mm (Height), LED backlight

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 4 4. Power Supply Power Source: AC 110V/230V (±10%) adaptor; 4 x UM-1 1.5V dry batteries; or 6V / 1.2Ah rechargeable battery Power Consumption: With backlight: about DC 14 mA; battery life about 85 hours Without backlight: about DC 24 mA; battery life about 50 hours Low Battery Indication: When the symbol flashes, the battery needs to be recharged or the dry battery needs to be replaced. 4 The scale will power off automatically after 1 to 2 hours if the battery is not charged. Please fully recharge the battery before using the scale again.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 5 CHAPTER 2 DISPLAY HI : When this indicator is on, the weight value is larger than the preset high limit. OK : When this indicator is on, the weight value is between the low and high limits. LO : When this indicator is on, the weight value is less than the preset low limit. kg : Indicating that the current weighing unit is “kg”. lb : Indicating that the current weighing unit is “lb”. Pcs : Indicating that the scale is in the simple counting mode. à0ß : “ZERO” indicator and platform stable confirmation. Net: When this indicator is on, the scale is in the tare mode, and the net weight is displayed. : “Low Battery” indicator 61 : (STABLE) “stable” indicator 62 : (GROSS) When this indicator is on, the scale is in the tare mode, and the gross weight is displayed. 63 : ( ) In the counting mode, when this indicator is on, the unit weight of the sample is too small. 64 : ( ) In the counting mode, when this indicator is on, the total weight of the sample is too small. 65 : (Hold) “Hold weight” indicator 66 : “GN”、“dwt”、“ct” unit indicator 67 : “oz” unit indicator 1 2 3 4 5 6 7

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 6 CHAPTER 3 KEYBOARD FUNCTION 1. : Pressed to switch the scale off 2. : When the scale is off, pressed to switch it on. When the scale is on, if the weight is within the zero range, this key is pressed to re-zero the display or cancel the tare mode. 4 Zero range: OIML & NTEP: ±2% of full scale; Sri Lanka: ±4% of full scale 3. : Pressed to deduct the container weight. 4. : Pressed to choose the unit weight “kg” or “lb”. 5. : Net /Gross weight conversion under tare mode. UNITS TARE OFF ON ZERO NET GROSS

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 7 CHAPTER 4 BASIC FUNCTION OPERATION 1. Switch On When the scale is off, press the key to switch on the scale 2. Re-Zero When there is no load on the platter, if the displayed weight is not zero and is within the zero range, press the key to re-zero the scale, and the indicator “à0ß” is on. 4 Zero range: OIML & NTEP: ±2% of full scale; Sri Lanka: ±4% of full scale 3. Unit Selection Press the key to choose the weight unit “kg”, “lb” or the counting unit “Pcs”. The unit indicator “kg”, “lb” or “Pcs” will be on. 4 When the scale is switched off, it will memorize the active unit in use, and when it is switched on again, the previous active unit will be shown on the display. UNITS ON ZERO ON ZERO

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 8 4. Tare Function (1) Put the container on the platter. When the weight displayed is stable, press the key. The weight of the container is thus deducted, and the “Net” indicator is on. (2) Put the object to be weighed into the container, and the display shows the net weight of the object. (3) Remove the container and the object together from the platter. The display will show the negative value of the container weight. (4) Press the key again, the negative value is cleared and the display returns to zero. The “Net” indicator is off. 4 Tare continuously: When the container weight increases or decreases continuously, it can all be deducted by pressing the key. 4 Tare value can be up to the full capacity of the scale. 5. Net/Gross Weight Conversion In the Tare mode, when the “Net” indicator is on, press the key once. The display will show the gross weight, the “Net” indicator is off, and the Gross indicator “6” is on. Press the key again, the display will show the net weight, the “Net” indicator is on, and the Gross indicator “6” is off. Thus by pressing the key, the net weight and the gross weight can be displayed alternately. 4 The key is functional only under Tare mode. 4 When the gross weight is displayed, no key but the key is functional. TARE TARE TARE NET GROSS NET GROSS NET GROSS NET GROSS

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 9 6. Simple Counting 6-1 Counting mode access Press the key to select the “Pcs” unit, and the scale enters the simple counting mode. 6-2 Sampling This important procedure is to let the scale calculate the unit weight: (1) Press the key to select a sample size 10, 20, 50, 100 or 200. (2) Put enough samples onto the platter according to the selected number, and then press the key. The display shows “- - - - - -” first. When the scale becomes stable, the display shows the number of samples on the platter. (3) Remove the samples from the platter, and the scale is ready to count. 6-3 Counting Place the objects to be counted onto the platter, and the quantity shows on the display. 4 When any of the following indicator is on, the scale can still count, but inaccuracy may occur: Sample too small ( ): total sample weight is less than 20 divisions Unit weight too small ( ): unit weight is less than 1/5 division. 4 The scale will memorize the last sample size when switched off, and the same can be used when the scale enters the counting mode next time. 4 If the number of samples changes by 5 pieces from the last sample used, the scale will calculate the new unit weight automatically. UNITS UNITS NET GROSS

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 10 Press the ON/ZERO key Press the UNITS key CHAPTER 5 ADVANCED FUNCTIONS SETTING 4 To access the advanced functions setting, press the NET/GROSS key and the ON/ZERO key at the same time when the scale is in the weighing mode. The display shows . Press the ON/ZERO key Press the UNITS key Press the ON/ZERO key Press the UNITS key ⇒ Functions Setting ⇒ External Weight Calibration ⇒ Exit Advanced Functions Setting

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 11 ⇒ Return to the upper level category ⇒ Auto backlight setting ⇒ Auto-off timer setting ⇒ Check-weighing setting ⇒ Restore to the factory setting ⇒ Environment parameter setting ⇒ Hold function setting 1. Function Setting 4 Six functions ~ can be set here. ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftward Press the TARE key Input “00 ~ 06” If input “00”, press the TARE key to return to the upper level category.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 12 Press the ON/ZERO or UNITS key to select “on” or “off”. 1-1 Auto Backlight Setting Press the TARE key The display shows the current backlight setting. Press the TARE key Auto backlight setting on ⇒ Turn on the auto backlight off ⇒ Turn off the auto backlight Auto backlight mode 1. When there is weight on the platter (the value is larger than 10 divisions), or when any key is pressed, the backlight is on. 2. After the weight on the platter keeps under 10 divisions while no key is pressed, the backlight will be off in about 10 seconds.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 13 Press the ON/ZERO or UNITS key to input a parameter Auto-off timer If the weight on the platter keeps under 10 divisions while no key is pressed, the scale will automatically switch off after waiting for the set time. 1-2 Auto-off Timer Setting ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftward Press the TARE key The display shows the current setting Press the TARE key Auto-off timer setting 0 ⇒ Auto-off not functional 1 ⇒ If the scale is not operated for 1 minute, it will automatically switch off. 2 ⇒ If the scale is not operated for 2 minutes, it will automatically switch off. 9 ⇒ If the scale is not operated for 9 minutes, it will automatically switch off.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 14 Input the desired high limit value Input the desired low limit value Input the buzzer parameters . . . . 1-3 Check-Weighing Setting 4 If both the preset high limit and the low limit values are set as 0, the check-weighing function is invalid. ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftward Press the TARE key The display shows the current setting of high limit value Press the TARE key kg The display shows the current setting of low limit value The display shows the current setting of buzzer parameters Press the TARE key Buzzer parameter setting (a) (b) (c) (a) 1 ⇒ the buzzer beeps to alarm 0 ⇒ the buzzer does not beep (b) 1 ⇒ beep stable 0 ⇒ beep unstable (c) 1 ⇒ beeps when the weight is between high and low limit. 0 ⇒ beeps when the weight is out of high and low limit. (Weight over 10d) kg kg kg Press the TARE key

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 15 Press the ON/ZERO or UNITS key to select “return” or “format”. 1-4 Restore to the Factory Setting 4 The restored factory settings include the following: (1) External weight calibration (2) Check-weighing setting (3) Environment parameter setting (4) Sampling value in counting mode 4 is not accessible for approval models. Press the TARE key Return to upper level category (abort restoring) Press the TARE key Restore to the factory setting

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 16 Use the ON/ZERO or UNITS key to input a parameter Use the ON/ZERO or UNITS key to input a parameter Use the ON/ZERO or UNITS key to input a parameter 1-5 Environment Parameter Setting 4 The parameters in remain the same after the ones has been modified in 4 is not accessible for approval models. ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftward Press the TARE key Return-to-zero-point setting Default setting = 0 0 ⇒ No skip 5 ⇒ skip 5d 1 ⇒ skip 1d 6 ⇒ skip 6d 2 ⇒ skip 2d 7 ⇒ skip 7d 3 ⇒ skip 3d 8 ⇒ skip 8d 4 ⇒ skip 4d 9 ⇒ skip 9d 4 The function is active when the weight is over 1/3 of full scale Digital switch & stabilization range setting The display shows the current setting Noise filter parameter setting The display shows the current setting Return-to-zero-point setting The display shows the current setting Noise filter parameter setting Parameters 0 ~ 9 selectable; Default setting = 5 The larger the number, the speeder the filter reacts. Therefore, larger parameter is suitable for unstable environment. Digital switch & stabilization range setting Parameters 0 ~ 9 selectable; Default setting = 0 The larger the number, the easier for the scale to get stable. Press the TARE key Press the TARE key Press the TARE key

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 17 Use the ON/ZERO or UNITS key to input a parameter 1-6 Hold Function Setting ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftward Press the TARE key Hold function setting Default setting = 0 0 ⇒ No hold function 1 ⇒ “peak” hold function mode 2 ⇒ “stable” hold function mode 1 3 ⇒ “stable” hold function mode 2 The display shows the current hold function mode Press the TARE key Press the TARE key to complete the function setting Input “00” ⇒ No Hold function ⇒ “Peak” hold function mode When the weight keeps changing, the scale will automatically hold and display the largest value. Press any key to clear the held value. ⇒ “Stable” hold function mode 1 When the scale becomes stable, the display shows and holds the weight value, which can not be changed. Press any key to clear the held value. ⇒ “Stable” hold function 2 When the scale becomes stable, the display shows and holds the weight value, which can not be changed. When the scale is re-zeroed (weight less than 10d), the held value is automatically cleared.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 18 Put the platter on and make sure there is no weight on the platter. Then press the TARE key. Place enough weight to the platter according to the display. When the scale becomes stable, the buzzer beeps for 3 times. Remove all the weights, and the calibration procedure is completed. . . 2. External Weight Calibration 4 is not accessible for approval models. 4 It is recommended that the external weight calibration should be carried out by a qualified technician from your supplier to ensure the accuracy of the scale. ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftward Press the TARE key The display shows the calibration weight (equals to the full capacity) and the weight unit. The last digit flashes. 4 The calibration weight can be modified if necessary. kg kg kg The scale is calculating the internal value of the zero point. The scale becomes stable The display shows the calibration weight.

EXCELL PRECISION CO., LTD.

Dolphin 9903 V 1.1 SME300000041 19 APPENDIX SEVEN-SEGMENT DISPLAY CHARACTERS Digit 7 segment letter Alphabet 7 segment letter Alphabet 7 segment letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z