Extech Instruments NON-DISPLAY PORTABLE Operation & User’s Manual

Brand: Extech Instruments
Category: Measuring Instruments
Model: NON-DISPLAY PORTABLE (Operation & User’s Manual)
File Type: PDF
File Size: 0.34 Mb
Pages: 14
Text of Extech Instruments NON-DISPLAY PORTABLE Operation & User’s Manual

Extech Instruments NON-DISPLAY PORTABLE Vane Thermo-Anemometer Datalogger

Model 451126 Introduction Congratulations on your purchase of Extech's Thermo-Anemometer Datalogger. This Vane-type Anemometer can indicate Air Velocity in five units of measure: Feet per minute, Meters per second, Miles per hour, Kilometers per hour, and Knots with Temperature displayed in oC or oF units. The meter can also display air flow in CFM or CMM. The built-in datalogger can record up to 2000 readings

Extech Instruments NON-DISPLAY PORTABLE Model 451126 Version 1.6 February 2004

2 Specifications General Specifications Display Dual 4-digit (9999 count) Multi-function LCD Data hold Locks latest reading on the LCD display Sensor Structure Air velocity sensor: Conventional twisted vane arm with low friction (sapphire) ball bearing. Temperature sensor: K-type thermocouple built into vane. 1/4" mounting nut provided Memory Recall Records Max/Min readings with push-key RECALL Data Output RS-232 PC
Model 451126 Version 1.6 February 2004 3 Meter Description 1. LCD Display 2. Vane Sensor 3. ON/OFF Key 4. RS-232 Connector 5. Function/Numeric Keypad LCD Display Icon Definitions AVE Average reading mode is selected oC Temperature is displayed in degrees centigrade MIN Minimum reading mode is selected oF Temperature is displayed in degrees Fahrenheit 2/3V 2/3V Maximum mode is selected CFM Cubic feet per minute (ft 3/min) MAX Maximum reading mode is selecte
Model 451126 Version 1.6 February 2004 4 Operation NOTE: For all air velocity or flow measurements, the air should pass through the vane from back to front. The rear of the vane can be found by locating the mounting nut. The front of the vane has the engraving "ANEMOMETER". For more accurate results, maintain a 20 o axis of air direction with the rear of the vane (refer to Fig.2). Air Velocity 1. Power the meter by pressing . 2. Select Air Velocity
Model 451126 Version 1.6 February 2004 5 2/3Vmax Air Flow 1. Power the meter by pressing . 2. Press to select Air Flow. FLOW will display. 3. Press to select the desired units (CFM, CMM). 4. The previously stored area value will be displayed on the upper LCD display line. To enter a new area value press . The lower display line will blank waiting for the user to program new data. Use the numeric keys to enter a new a
Model 451126 Version 1.6 February 2004 6 Datalogging Instantaneous (One-Shot) Datalogging To record one data point at any desired time, set the sampling rate = 0 by pressing in the VEL mode. The previously stored reading will be displayed on the upper LCD line. Enter a '0' sampling time and then press . Now, each time is pressed, the present reading will be stored in non-volatile memory. Automatic Datalogging 1. Set the Sampling rate
Model 451126 Version 1.6 February 2004 7 Software The 451126 software lets the user: • Download logged recordings from the meter’s memory • Record to the PC • Graphically display readings from the meter System Requirements Hardware Requirements: 486 PC or better with COM 1 and COM 2 Serial ports Operating System Compatibility: Windows TM 95/98/NT/2000/XP Hardware Connection The IR Thermometer connects to a PC with the supplied DB-9 to DB-9 interfac
Model 451126 Version 1.6 February 2004 8 Starting the Software 1. Run the program by opening the program named “Flow Anemometer”. Flow Anemometer is in the programs folder of your Windows software. 2. Wait for the program to initialize and select COM 1 or 2 as required. The program will load and the main display will appear. A red NO COM icon will flash on the bottom right hand side of the display. 3. Press and hold then power on the meter by
Model 451126 Version 1.6 February 2004 9 Operating the Software Graphical Display Mode The display command offers 5 different displays. Click Display on menu bar to select. Click Option to set Upper and Lower Limits. The software will then flag readings exceeding the limits. Main Display Digital Display Click Reset button on main display to clear Min/Max Analog Display Graphical Display
Model 451126 Version 1.6 February 2004 10 Data Acquisition Mode In data acquisition mode the meter is connected to a PC with the data being saved directly to the PC’s memory. 1. In the Flow Anemometer program, click File, and then click Name. Enter a file name and click OK 2. Click Option then Sample, enter a sampling interval and then click OK 3. Click File then Start Recording. 4. To stop the meter click File then click End Recording.

Extech Instruments Measuring Instruments Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
ExStik PH100

Measuring Instruments #J279V9

8 116 27 17-05-2026
480826

Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 27-06-2026)

4 1040 188 27-06-2026
SDL300

PDF Manual (@QRS6EY), Extech Instruments SDL300 Measuring Instruments (26-06-2026)

13 710 114 26-06-2026
PQ34-12

Extech Instruments Measuring Instruments Manual  (File: PDF, 01-09-2026)

4 787 189 01-09-2026
461893

461893 Operation & user’s manual - 5JI548

7 559 96 21-08-2026
407113

407113 Operation & user’s manual - 68Z489

10 185 28 09-10-2026
461825

Measuring Instruments #287TKD

4 1013 173 06-06-2026

Measuring Instruments: Similar Manuals