SYSTEM CONTROL KIT
Model: CK-81
Designed for use with the SWG Series Power Venter for controlling 750 millivolt controlled Natural
and L.P. Gas appliances with a 24AC voltage thermostat or wall switch, such as a gas fireplace.
NOTE: The use of flue gas spillage switches such as The Field Controls Model GSK-3, or equivalent,
is recommended. Manual operation
MOUNTING JUNCTION BOX
The junction box can be mounted at the venter or remotely mounted away from the
venter. (See Figures 1 & 2)
1. Remove one of the knockouts from the side of the junction box where the pressure
switch is mounted. Install the flexible conduit connector onto the CK-81 junction box
and secure with fastening nut. If remote mounting the
PRESSURE SWITCH SENSING TUBE INSTALLATION
1. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. (See Figure 3)
2. Connect the supplied 1/4" aluminum tubing to the tubing connector. Route the tubing to the CK-81 junction box and
connect the tubing to the pressure switch. When routing the tubing, avoid kinking the tubing by ben