FieldServer Envirotronics SystemsPlus FS-8700-88 Driver Manual

Text of the manual

A Sierra Monitor Company

APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after May 1, 2001 Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-88 Envirotronics SystemsPlus Driver Version: 1.02 Document Revision: 6

FS-8700-88 Envirotronics SystemsPlus

Table of Contents FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected] TABLE OF CONTENTS 1. ENVIROTRONICS SYSTEMSPLUS DESCRIPTION........................................................5 2. DRIVER SCOPE OF SUPPLY..........................................................................................6 2.1. Supplied by FieldServer Technologies for this driver ..................................................6 3. HARDWARE CONNECTIONS..........................................................................................7 4. CONFIGURING THE FIELDSERVER AS A ENVIROTRONICS SYSTEMSPLUS CLIENT 8 4.1. Data Arrays/Descriptors..............................................................................................8 4.2. Client Side Connection Descriptions...........................................................................9 4.3. Client Side Node Descriptors......................................................................................9 4.4. Client Side Map Descriptors......................................................................................10 4.4.1. FieldServer Related Map Descriptor Parameters...................................................10 4.4.2. Driver Related Map Descriptor Parameters ...........................................................10 4.4.3. Timing Parameters ................................................................................................10 4.4.4. Map Descriptor Example 1 - read event event_num ..............................................11 4.4.5. Map Descriptor Example 2 - set event event_num = Boolean................................11 4.4.6. Map Descriptor Example 3 - read aux. aux_num...................................................11 4.4.7. Map Descriptor Example 4 - set aux. aux_num = Boolean.....................................11 4.4.8. Map Descriptor Example 5 - read setpoint channel................................................12 4.4.9. Map Descriptor Example 6 - set setpoint channel = value......................................12 4.4.10. Map Descriptor Example 7 - read pv channel.....................................................12 4.4.11. Map Descriptor Example 8 - read deviation channel...........................................12 4.4.12. Map Descriptor Example 9 - read initial setpoint channel ...................................13 4.4.13. Map Descriptor Example 10 - set initial setpoint channel = value .......................13 4.4.14. Map Descriptor Example 11 - read program status.............................................13 4.4.15. Map Descriptor Example 12 - read remaining step cycles ..................................14 4.4.16. Map Descriptor Example 13 - read selected program.........................................14 4.4.17. Map Descriptor Example 14 - read step number.................................................14 4.4.18. Map Descriptor Example 15 - read step time......................................................14 4.4.19. Map Descriptor Example 16 - read remaining step time .....................................15 4.4.20. Map Descriptor Example 17 -read start step.......................................................15 4.4.21. Map Descriptor Example 18 - set start step = step_num ....................................15 4.4.22. Map Descriptor Example 19 - read start time enabled........................................15 4.4.23. Map Descriptor Example 20 - set start time enabled = Boolean .........................16 4.4.24. Map Descriptor Example 21 - read stop time enabled ........................................16 4.4.25. Map Descriptor Example 22 - set stop time enabled = Boolean..........................16 4.4.26. Map Descriptor Example 23 - read start time......................................................17 4.4.27. Map Descriptor Example 24 - read stop time......................................................17 4.4.28. Map Descriptor Example 25 - read audible alarm...............................................17 4.4.29. Map Descriptor Example 26 - set audible alarm = Boolean ................................18 4.4.30. Map descriptor Example 27 - read software version...........................................18 4.4.31. Map Descriptor Example 28 - read events..........................................................18 4.4.32. Map Descriptor Example 29 - read auxs.............................................................19 4.4.33. Map Descriptor Example 30 - read alarm status alarm.......................................19 4.4.34. Map Descriptor Example 31 - emergency stop...................................................19 4.4.35. Map Descriptor Example 32 - hold program .......................................................20 4.4.36. Map Descriptor Example 33 - resume program ..................................................20 4.4.37. Map Descriptor Example 34 - start program .......................................................20 4.4.38. Map Descriptor Example 35 - start system.........................................................20

FS-8700-88 Envirotronics SystemsPlus

Table of Contents FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected] 4.4.39. Map Descriptor Example 36 - stop program .......................................................21 4.4.40. Map Descriptor Example 37 - stop system .........................................................21 4.4.41. Map Descriptor Example 38 - alarm reset...........................................................21 4.4.42. Map Descriptor Example 39 - alarm acknowledge..............................................21 4.4.43. Map Descriptor Example 40 - edit alarms...........................................................22 4.4.44. Map Descriptor Example 41 - set circulators = Boolean .....................................22 4.4.45. Map Descriptor Example 42 - set lights = Boolean .............................................22 4.4.46. Map Descriptor Example 43 - select program program_num..............................22 4.4.47. Map Descriptor Example 44 - use keypad = Boolean .........................................23 4.4.48. Map Descriptor Example 45 - edit program program_num .................................23 4.4.49. Map Descriptor Example 46 - edit step step_num ..............................................23 4.4.50. Map Descriptor Example 47 - edit analog channel..............................................23 4.4.51. Map Descriptor Example 48 - edit fuzzy channel................................................24 4.4.52. Map Descriptor Example 49 - edit remove step..................................................24 4.4.53. Map Descriptor Example 50 - edit insert step .....................................................24 4.4.54. Map Descriptor Example 51 - edit add step........................................................24 4.4.55. Map Descriptor Example 52 - edit clear program................................................25 4.4.56. Map Descriptor Example 53 - use emulator mode..............................................25 4.4.57. Map Descriptor Example 54 - end edit mode......................................................25 4.4.58. Map Descriptor Example 55 - edit set cycles = num_cycles ...............................25 4.4.59. Map Descriptor Example 56 - edit set next = next_step_num.............................26 4.4.60. Map Descriptor Example 57 - edit set analog min. = value .................................26 4.4.61. Map Descriptor Example 58 - edit set analog max. = value ................................26 4.4.62. Map Descriptor Example 59 - edit set analog type = number..............................26 4.4.63. Map Descriptor Example 60 - edit set engineering min. = value .........................27 4.4.64. Map Descriptor Example 61 - edit set engineering max. = value ........................27 4.4.65. Map Descriptor Example 62 - edit set analog address = number........................27 4.4.66. Map Descriptor Example 63 - edit set units = number ........................................27 4.4.67. Map Descriptor Example 64 - edit set fuzzy heat cycles time = value.................28 4.4.68. Map Descriptor Example 65 - edit set fuzzy cool cycles time = value .................28 4.4.69. Map Descriptor Example 66 - edit set fuzzy heat sensitivity = value...................28 4.4.70. Map Descriptor Example 67- edit set fuzzy cool sensitivity = value ....................28 4.4.71. Map Descriptor Example 68 - edit set fuzzy heat max. power = value................29 4.4.72. Map Descriptor Example 69 - edit set fuzzy cool max. power = value.................29 4.4.73. Map Descriptor Example 70 - edit set fuzzy heat min. time = value....................29 4.4.74. Map Descriptor Example 71 - edit set fuzzy cool min. time = value ....................29 4.4.75. Map Descriptor Example 72 - edit set fuzzy heat stage delay = value ................30 4.4.76. Map Descriptor Example 73 - edit set fuzzy cool stage delay = value.................30 4.4.77. Map Descriptor Example 74 - edit set fuzzy dead band = value .........................30 4.4.78. Map Descriptor Example 75 - edit set duration = hour:minute:second................31 4.4.79. Map Descriptor Example 76 - set start time = month/day hour:minute................31 4.4.80. Map Descriptor Example 77 - set stop time = month/day hour:minute................32 4.4.81. Map Descriptor Example 78 - set date = month / day / year ...............................32 4.4.82. Map Descriptor Example 79 - set time = hour:minute:second.............................33 4.4.83. Map Descriptor Example 80 - edit set setpoint channel = value..........................33 4.4.84. Map Descriptor Example 80 - edit set gsoak channel = value.............................34 4.4.85. Map Descriptor Example 81 - edit set gsoak enabled channel = Boolean...........34 4.4.86. Map Descriptor Example 82 - edit set events = event_list...................................35 4.4.87. Map Descriptor Example 83 - edit set auxs = aux_list ........................................35 4.4.88. Map Descriptor Example 84 - edit read program ................................................36 4.4.89. Map Descriptor Example 85 - edit read step.......................................................36

FS-8700-88 Envirotronics SystemsPlus

Table of Contents FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected] 4.4.90. Map Descriptor Example 86 - edit read number steps........................................36 4.4.91. Map Descriptor Example 87 - edit read duration.................................................37 4.4.92. Map Descriptor Example 88 - edit read events...................................................37 4.4.93. Map Descriptor Example 89 - edit read aux........................................................38 4.4.94. Map Descriptor Example 90 - edit read cycles....................................................38 4.4.95. Map Descriptor Example 91 - edit read next.......................................................39 4.4.96. Map Descriptor Example 92 - edit read analog min. ...........................................39 4.4.97. Map Descriptor Example 93 - edit read analog max. ..........................................39 4.4.98. Map Descriptor Example 94 - edit read analog type ...........................................40 4.4.99. Map Descriptor Example 95 - edit read engineering min. ...................................40 4.4.100. Map Descriptor Example 96 - edit read engineering max. ...............................40 4.4.101. Map Descriptor Example 97 - edit read analog address..................................41 4.4.102. Map Descriptor Example 98 - edit read units...................................................41 4.4.103. Map Descriptor Example 99 - edit read fuzzy heat cycle time..........................41 4.4.104. Map Descriptor Example 100 - edit read fuzzy cool cycle time........................42 4.4.105. Map Descriptor Example 101 - edit read fuzzy heat sensitivity........................42 4.4.106. Map Descriptor Example 102 - edit read fuzzy cool sensitivity ........................42 4.4.107. Map Descriptor Example 103 - edit read fuzzy heat max. power.....................43 4.4.108. Map Descriptor Example 104 - edit read fuzzy cool max. power .....................43 4.4.109. Map Descriptor Example 105 - edit read fuzzy heat min. time.........................43 4.4.110. Map Descriptor Example 106 - edit read fuzzy cool min. time .........................44 4.4.111. Map Descriptor Example 107 - edit read fuzzy heat stage delay .....................44 4.4.112. Map Descriptor Example 108 - edit read fuzzy cool stage delay......................44 4.4.113. Map Descriptor Example 109 - edit read fuzzy dead band ..............................45 4.4.114. Map Descriptor Example 110 - read alarm log ................................................45 4.4.115. Map Descriptor Example 111 - edit read setpoint channel...............................45 4.4.116. Map Descriptor Example 112 - edit read gsoak enabled channel....................46 4.4.117. Map Descriptor Example 113 - edit read gsoak channel..................................46 4.4.118. Map Descriptor Example 114 - edit read scan alarm.......................................46 4.4.119. Map Descriptor Example 115 - edit set scan alarm = Boolean.........................47 APPENDIX A. PARAMETER TABLES .................................................................................48 Appendix A.1. System plus data types................................................................................48 Appendix A.2. Legal System PlusCommands.....................................................................48

FS-8700-88 Envirotronics SystemsPlus

Page 5 of 49 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected] 1. Envirotronics SystemsPlus Description The Envirotronics SystemsPlus driver allows the FieldServer to transfer data to and from devices over RS-232 using Envirotronics SystemsPlus protocol. The FieldServer can only emulate a Client. Max Nodes Supported FieldServer Mode Nodes Comments Client 1 Only 1 Client node per port allowed The Envirotronics SystemsPlus driver allows for direct interfacing to a SystemsPlus Programmer/Controller device. The driver acts as a Client to the device and can be used to read and set system parameters for status monitoring and control purposes. Combined with other protocol drivers on a FieldServer such as BACNet, complete SystemsPlus monitoring and control is made possible via control systems such as Scada. The driver is not available as a Server since a FieldServer cannot fully emulate a SystemsPlus device’s interfaces. Any existing Server drivers are for FieldServer testing purposes only.

Other Storage Manuals