Dell OptiPlex E1 Troubleshooting Manual
Read Online
Read the Dell OptiPlex E1 Troubleshooting Manual online using the built-in PDF viewer.
Text of the manual
Information in this document is subject to change without notice.
1989–1997 Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Dell Dimension, and PowerEdge are registered trademarks, and DellWare is a registered
service mark of Dell Computer Corporation; Pentium is a registered trademark of Intel Corporation; Microsoft, MS-DOS, Windows, and
Windows NT are registered trademarks of Microsoft Corporation; CompuServe is a registered trademark of CompuServe, Inc.; and Lotus is a
registered trademark of Lotus Development Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Dell Computer Corporation disclaims any proprietary interest in trademarks and trade names other than its own.
October 1997 P/N 08220 Rev. A06
Use the following safety guidelines to help protect
your computer system from potential damage and to
ensure your own personal safety.
When Using Your Computer
System
As you use your computer system, observe the following
safety guidelines:
•
To help avoid damaging your computer, be sure the
voltage selection switch on the power supply is set to
match the alternating current (AC) power available
at your location:
— 115 volts (V)/60 hertz (Hz) in most of North and
South America and some Far Eastern countries
such as Japan, South Korea, and Taiwan
— 230 V/50 Hz in most of Europe, the Middle
East, and the Far East
Also be sure your monitor and attached peripherals
are electrically rated to operate with the AC power
available in your location.
•
To help avoid possible damage to the system board,
wait 5 seconds after turning off the system before
removing a component from the system board or dis-
connecting a peripheral device from the computer.
•
To help prevent electric shock, plug the computer
and peripheral power cables into properly grounded
power sources. These cables are equipped with
3-prong plugs to help ensure proper grounding. Do
not use adapter plugs or remove the grounding prong
from a cable. If you must use an extension cable, use
a 3-wire cable with properly grounded plugs.
•
To help protect your computer system from sudden,
transient increases and decreases in electrical power,
use a surge suppressor, line conditioner, or un-
interruptible power supply (UPS).
•
Be sure nothing rests on your computer system’s
cables and that the cables are not located where they
can be stepped on or tripped over.
•
Do not spill food or liquids on your computer. If the
computer gets wet, see “Troubleshooting a Wet
Computer” in Chapter 6.
•
Do not push any objects into the openings of your
computer. Doing so can cause fire or electric shock
by shorting out interior components.
•
Keep your computer away from radiators and heat
sources. Also, do not block cooling vents. Avoid
placing loose papers underneath your computer, and
do not place your computer in a closed-in wall unit
or on a bed, sofa, or rug.
When Working Inside Your
Computer
Before you remove the computer cover, perform the fol-
lowing steps in the sequence indicated.
1.
Turn off your computer and any peripherals.
2.
Disconnect your computer and peripherals from
their power sources. Also, disconnect any tele-
phone or telecommunication lines from the
computer.
Doing so reduces the potential for personal injury or
shock.
3.
Touch an unpainted metal surface on the chassis,
such as the metal around the card-slot openings
at the back of the computer, before touching any-
thing inside your computer.
While you work, periodically touch an unpainted
metal surface on the computer chassis to dissipate
any static electricity that might harm internal
components.
In addition, take note of these safety guidelines when
appropriate:
•
When you disconnect a cable, pull on its connector
or on its strain-relief loop, not on the cable itself.
Some cables have a connector with locking tabs; if
you are disconnecting this type of cable, press in on
the locking tabs before disconnecting the cable. As
you pull connectors apart, keep them evenly aligned
to avoid bending any connector pins. Also, before
you connect a cable, make sure both connectors are
correctly oriented and aligned.
•
Handle components and cards with care. Don’t touch
the components or contacts on a card. Hold a card by
its edges or by its metal mounting bracket. Hold a
component such as a microprocessor chip by its
edges, not by its pins.
Protecting Against Electrostatic
Discharge
Static electricity can harm delicate components inside
your computer. To prevent static damage, discharge static
electricity from your body before you touch any of your
computer’s electronic components, such as the micro-
processor. You can do so by touching an unpainted metal
surface on the computer chassis.
As you continue to work inside the computer, periodi-
cally touch an unpainted metal surface to remove any
static charge your body may have accumulated.
You can also take the following steps to prevent damage
from electrostatic discharge (ESD):
•
When unpacking a static-sensitive component from
its shipping carton, do not remove the component
from the antistatic packing material until you are
ready to install the component in your computer. Just
before unwrapping the antistatic packaging, be sure
to discharge static electricity from your body.
•
When transporting a sensitive component, first place
it in an antistatic container or packaging.
•
Handle all sensitive components in a static-safe area. If
possible, use antistatic floor pads and workbench pads.
The following caution may appear throughout this docu-
ment to remind you of these precautions:
CAUTIONS: Do not attempt to service the com-
puter system yourself, except as explained in this
guide and elsewhere in Dell documentation. Always
follow installation and service instructions closely.
To help avoid possible damage to the system board,
wait 5 seconds after turning off the system before
removing a component from the system board or
disconnecting a peripheral device from the
computer.
WARNING
There is a danger of a new battery exploding if it is
incorrectly installed. Replace the battery only with
the same or equivalent type recommended by the
manufacturer. Discard used batteries according to
the manufacturer’s instructions.
CAUTION: See “Protecting Against Electrostatic
Discharge” in the safety instructions at the front of
this guide.
About This Guide
This guide provides directions for troubleshooting prob-
lems that have temporarily disabled your Dell computer
system. It does not matter how much you do or do not
know about your system—this guide can help you.
Before calling for technical assistance, follow the recom-
mended procedure(s) in this guide to solve many
hardware and software problems yourself. The chapters
and appendixes are summarized as follows:
•
Everyone should read Chapter 1, “Checking the
Basics,” for some initial checks and procedures that
can be used to solve basic computer problems. It also
directs you to the appropriate chapter in this guide
for more detailed troubleshooting information and
procedures to solve more complex problems.
•
Whenever you receive an error message or code, you
should read Chapter 2, “Messages and Codes.” This
chapter discusses system messages, system beep
codes, warning messages, and diagnostics messages.
•
If you suspect that your problems are software-
related, or you are still having problems after testing
your computer’s hardware, read Chapter 3, “Finding
Software Solutions.” It provides some general guide-
lines for analyzing software problems.
•
For hardware-related problems, read Chapter 4,
“Running the Dell Diagnostics.” Chapter 5, “Check-
ing Your Equipment,” and Chapter 6, “Checking
Inside Your Computer,” provide troubleshooting
procedures for equipment connected to the input/
output (I/O) panel of your computer and components
inside your computer, respectively.
•
Chapter 7, “Getting Help,” describes the help tools
Dell provides to assist you should you have a prob-
lem with your computer system. It also explains how
and when to call Dell for technical assistance. Make
a copy of the Diagnostics Checklist in Chapter 7 and
fill it out as you perform the troubleshooting proce-
dures. If you need to call Dell for technical
assistance, use the completed checklist to tell the
support technician what procedures you performed
to better help the technician give you assistance. If
you must return a piece of hardware to Dell, include
a filled-out checklist.
•
Appendix A, “Diagnostic Video Tests,” discusses the
tests for the Video Test Group in the Dell Diagnos-
tics to help you test your monitor.
•
A table of the abbreviations and acronyms used
throughout this guide and in other Dell documenta-
tion for your system precedes the Index.
Warranty and Return Policy
Information
Dell Computer Corporation (“Dell”) manufactures its
hardware products from parts and components that are
new or equivalent to new in accordance with industry-
standard practices. For information about the Dell war-
ranty, see the appendix titled “Warranties and Return
Policy” in your system documentation.
Other Documents You May Need
You may need to reference the following documentation
when performing the procedures in this guide:
•
Your system documentation describes system fea-
tures, explains the System Setup program, explains
the ISA Configuration Utility or EISA Configuration
Utility (whichever is provided with your system),
tells how to install internal options, and also pro-
vides technical specifications for your computer
system. On some systems, some of this information
is provided in online form in the Dell Accessories
group.
•
The Getting Started sheet (which accompanies only
certain systems) provides step-by-step instructions
for setting up your computer system.
•
The Frequently Asked Questions cards (which
accompany only certain systems) provide detailed
answers to questions that are often asked by Dell
computer users. Be sure to read these cards before
calling Dell for technical assistance.
•
Operating system documentation is included with
your system if you ordered your operating system
software from Dell. This documentation describes
how to install (if necessary), configure, and use your
operating system software.
•
Documentation is included with any options you
purchase separately from your system. This docu-
mentation includes information that you need to
configure and install these options in your Dell com-
puter. Installation instructions for the options are
included in your system documentation.
•
The SCSI Device Driver Installation and Configura-
tion Guide contains information required when
installing SCSI devices on your system.
•
The Dell SCSI Array User’s Guide provides instruc-
tions that you need to run the DSA Manager program
when troubleshooting SCSI disk drives.
•
Technical information files—sometimes called
“readme” files—may be installed on your hard-disk
drive to provide last-minute updates about technical
changes to your system or advanced technical refer-
ence material intended for experienced users or
technicians.
NOTE: Documentation updates are sometimes included
with your system to describe changes to your system or
software. Always read these updates before consulting
any other documentation because the updates often con-
tain information that supersedes the information in the
other documents.
Notational Conventions
The following subsections list notational conventions
used in this document.
Warnings, Cautions, and Notes
Throughout this guide, there may be blocks of text
printed in bold type within boxes or in italic type. These
blocks are warnings, cautions, and notes, and they are
used as follows:
NOTE: A NOTE indicates important information that
helps you make better use of your computer system.
Typographical Conventions
The following list defines (where appropriate) specific
elements of text and illustrates the typographical conven-
tions used throughout this document as visual cues for
those elements:
•
Keycaps, the labeling that appears on the keys on a
keyboard, are enclosed in angle brackets.
Example:
•
Key combinations are series of keys to be pressed
simultaneously (unless otherwise indicated) to per-
form a single function.
Example:
•
Commands presented in lowercase bold are for refer-
ence purposes only and are not intended to be typed
when referenced.
Example: “Use the format command to . . . .”
WARNING: A WARNING indicates the potential
for bodily harm and tells you how to avoid the
problem.
CAUTION: A CAUTION indicates either potential
damage to hardware or loss of data and tells you
how to avoid the problem.
In contrast, commands presented in the Courier New
font are part of an instruction and intended to be
typed.
Example: “Type format a: to format the diskette
in drive A.”
•
Filenames and directory names are presented in low-
ercase bold.
Examples: autoexec.bat and c:\windows
•
Syntax lines consist of a command and all its
possible parameters. Commands are displayed in
lowercase bold; variable parameters (those for which
you substitute a value) are displayed in lowercase
italics; constant parameters are displayed in lower-
case bold. The brackets indicate items that are
optional.
Example: del [drive:] [path] filename [/p]
•
Command lines consist of a command and may
include one or more of the command’s possible
parameters. Command lines are presented in the
Courier New font.
Example: del c:\myfile.doc
•
Screen text is text that appears on the screen of your
monitor or display. It can be a system message, for
example, or it can be text that you are instructed to
type as part of a command (referred to as a command
line). Screen text is presented in the Courier New
font.
Example: The following message appears on your
screen:
No boot device available
Example: “Type md c:\dos and press .”
•
Variables are placeholders for which you substitute a
value. They are presented in italics.
Example: SIMMn (where n represents the SIMM socket
designation)
Checking the Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Backing Up Your Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Basic Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Checking Connections and Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Look and Listen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
The System Setup Program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
The EISA Configuration Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Chapter 2
Messages and Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
System Beep Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Warning Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Diagnostics Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Chapter 3
Finding Software Solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Installing and Configuring Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Expanded and Extended Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Using Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Input Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Memory-Resident Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Program Conflicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Checking for Memory Address Conflicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Avoiding Interrupt Assignment Conflicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Running the Dell Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Features of the Dell Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
When to Use the Dell Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Before You Start Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Starting the Dell Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
How to Use the Dell Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Confirming the System Configuration Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
How to Use the Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Main Menu Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Run Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Select Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Options Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Test Limits Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
About Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Key-Help Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Quit Menu Under Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Number of Times to Repeat Test(s). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Maximum Errors Allowed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Pause for User Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Output Device for Status Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Output Device for Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Test Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
About. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Key-Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Quit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Tests in the Dell Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
RAM Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Why Run a RAM Test?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
System Set Test Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Why Run a System Set Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Video Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Why Run a Video Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Keyboard Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Why Run a Keyboard Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Mouse Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Why Run the Mouse Test?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Diskette Drives Test Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Why Run a Diskette Drives Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Hard-Disk Drives (Non-SCSI) Test Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Why Run a Hard-Disk Drives Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
IDE CD ROM Drives Test Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Why Run an IDE CD ROM Drives Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Serial/Infrared Ports Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Why Run a Serial/Infrared Ports Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Parallel Ports Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
Why Run a Parallel Ports Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
SCSI Devices Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
Why Run a SCSI Devices Test?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
Network Interface Test Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Why Run a Network Interface Test? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Audio Test Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Why Run an Audio Test?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Other Test Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Subtests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Checking Your Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Troubleshooting the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Troubleshooting the Keyboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Troubleshooting I/O Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Troubleshooting the Basic I/O Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
Troubleshooting a Parallel Printer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Troubleshooting a Serial I/O Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Chapter 6
Checking Inside Your Computer . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Safety First—For You and Your Computer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Removing and Replacing the Computer Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Troubleshooting a Wet Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Troubleshooting a Damaged Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Troubleshooting the Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Troubleshooting Expansion Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Troubleshooting System Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Troubleshooting the Video Subsystem. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Troubleshooting the System Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
Troubleshooting the Diskette/Tape Drive Subsystem . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Checking the Diskette/Tape Drive Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Troubleshooting a Diskette-Drive Subsystem. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Troubleshooting a Non-SCSI Internal Tape Drive . . . . . . . . . . . . . . . . . . . . . . 6-11
Troubleshooting a SCSI Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12
Troubleshooting Hard-Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14
Troubleshooting IDE Hard-Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14
Troubleshooting SCSI Hard-Disk Drives
in a System Without a SCSI Backplane Board . . . . . . . . . . . . . . . . . . . . . . . . 6-15
Troubleshooting SCSI Hard-Disk Drives
in a System With a SCSI Backplane Board . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17
Chapter 7
Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Help Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Frequently Asked Questions Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
Dell Q&A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
System Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
World Wide Web on the Internet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
Commercial Online Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
Dell Diagnostics Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
AutoTech Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
TechFax Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Automated Order-Status System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Technical Support Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Problems With Your Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Returning Items for Warranty Repair or Credit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Before You Call. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Dell Contact Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Appendix A
Diagnostic Video Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Video Memory Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Video Hardware Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Text Mode Character Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Character Attributes Subtest (80 x 25). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-2
Character Set Subtest (80 x 25) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3
Video Scan Alignment Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4
Character Attributes Subtest (40 x 25). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-6
Character Set Subtest (40 x 25) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-7
Text Mode Color Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-8
Color Attributes Subtest (80 x 25) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-8
Color Attributes Subtest (40 x 25) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-9
Color Bars Subtest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-9
Text Mode Pages Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-9
Graphics Mode Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-10
320 x 200 Graphics Mode Screens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-10
640 x 200 Black/White Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . .A-10
640 x 480 Monochrome Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . .A-12
320 x 200 16-Color Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . .A-13
640 x 200 16-Color Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . .A-13
640 x 350 16-Color Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . .A-13
640 x 480 2-Color Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-13
640 x 480 16-Color Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . .A-15
320 x 200 256-Color Graphics Mode Screen. . . . . . . . . . . . . . . . . . . . . . . . . . .A-15
640 x 480 256-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . . A-15
800 x 600 16-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . A-15
800 x 600 256-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . . A-15
1024 x 768 16-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . . A-15
1024 x 768 256-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . A-15
1280 x 1024 16-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . A-15
Color Palettes Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-15
Solid Colors Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-16
Abbreviations and Acronyms
Index
Figures
Figure 4-1.
Diagnostics Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Figure 4-2.
Dell Diagnostics Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Figure 7-1.
Diagnostics Checklist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
Figure A-1.
80-Column x 25-Line Character Attributes Subtest Screen . . . . . . . A-2
Figure A-2.
80-Column x 25-Line Character Set Subtest Screen . . . . . . . . . . . . . A-3
Figure A-3.
Video Scan Alignment Subtest (Screen 1). . . . . . . . . . . . . . . . . . . . . A-4
Figure A-4.
Video Scan Alignment Subtest (Screen 2). . . . . . . . . . . . . . . . . . . . . A-5
Figure A-5.
40-Column x 25-Line Character Attributes Subtest Screen . . . . . . . A-6
Figure A-6.
40-Column x 25-Line Character Set Subtest Screen . . . . . . . . . . . . . A-7
Figure A-7.
Text Mode Pages Test Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
Figure A-8.
640 x 200 Black/White Graphics Mode Screen. . . . . . . . . . . . . . . . A-11
Figure A-9.
640 x 480 Monochrome Graphics Mode Screen . . . . . . . . . . . . . . . A-12
Figure A-10.
640 x 480 2-Color Graphics Mode Screen . . . . . . . . . . . . . . . . . . . A-14
Tables
Table 1-1.
Boot Routine Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Table 2-1.
System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Table 2-2.
System Beep Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Table 3-1.
Default IRQ Line Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Table 4-1.
Option Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Table 4-2.
Dell Diagnostics Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Table 7-1.
Help Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Table 7-2.
International Dialing Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
Table 7-3.
Dell Contact Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10
Table A-1.
Color Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Checking the Basics
1-1
Chapter 1
Checking the Basics
If your Dell® computer system is not working as
expected, and if you are not sure what to do, start your
troubleshooting with the procedures in this chapter. This
chapter guides you through some initial checks and pro-
cedures that can solve basic computer problems. It can
also direct you to the appropriate chapter in this guide for
detailed troubleshooting information and procedures to
solve more complex problems.
NOTE: When you see the question, “Is the problem
resolved?” in a troubleshooting procedure, perform the
operation that caused the problem to see if the problem
recurs.
Backing Up Your Files
You can lose data when a system failure occurs. If your
system is behaving erratically, back up your files
immediately.
If you are using MS-DOS®, use the msbackup command
to copy your files onto diskettes to safeguard your data.
See your MS-DOS documentation for instructions on
using the msbackup command.
If Dell installed MS-DOS on your hard-disk drive, you
should also safeguard your software by creating program
diskette sets (backup diskettes) of the operating system
and application programs with Dell’s Program Diskette
Maker utility.
If you are using an operating system other than MS-DOS,
see the documentation that came with your operating sys-
tem for instructions on how to back up your files.
Basic Checks
The following procedure leads you through the checks
necessary to solve some basic computer problems:
1.
Is your computer wet or damaged?
Yes. Go to Chapter 6, “Checking Inside Your
Computer.”
No. Go to step 2.
2.
Perform the steps in “Checking Connections and
Switches” found later in this chapter.
Is the problem resolved?
Yes. The power to your computer system was faulty,
or the connections to your computer system were
loose. You have fixed the problem.
No. Go to step 3.
3.
Perform the steps in “Look and Listen” found
later in this chapter.
Did your computer system complete the start-up
(boot) routine?
NOTE: The boot routine is the operating system’s
attempt to load its files into memory from the boot-
up sector on the hard-disk drive or bootable diskette.
Yes. Go to step 4.
No. A serious malfunction may have occurred. Go
to Chapter 7, “Getting Help.”
4.
Did you receive a system message or beep code?
Yes. If your system documentation contains an
appendix titled “Beep Codes and System Messages,”
go to that appendix. Otherwise, go to Chapter 2,
“Messages and Codes,” in this guide.
No. Go to step 5.
Diagnostics and Troubleshooting Guide
5.
Verify the settings in the System Setup program
as explained in “The System Setup Program”
found later in this chapter.
Is the problem resolved?
Yes. The system configuration information was
incorrect. You have fixed the problem.
No. Go to step 6.
6.
Do you have an Extended Industry-Standard
Architecture (EISA) computer system?
Yes. Go to step 7.
No. Go to step 8.
7.
Use the EISA Configuration Utility to save new
system information into EISA configuration
memory as explained in “The EISA Configura-
tion Utility” found later in this chapter.
Is the problem resolved?
Yes. The EISA configuration information and the
system configuration information conflicted. You
have fixed the problem.
No. Go to step 8.
8.
Go to Chapter 4, “Running the Dell Diagnostics.”
Checking Connections and
Switches
Improperly set switches and controls, and loose or
improperly connected cables, are the most likely source
of problems for your computer, monitor, or other periph-
eral (such as a printer, keyboard, mouse, or other external
equipment). A quick check of all the switches, controls,
and cable connections can easily solve these problems.
NOTE: See your system documentation for the location
of your computer’s external connections and switches.
Complete the following procedure to check all the con-
nections and switches:
1.
Turn off the system, including any attached
peripherals (such as the monitor, keyboard,
printer, external drives, scanners, or plotters).
Disconnect all the alternating current (AC) power
cables from their power sources.
2.
If your computer is connected to a power strip,
turn the power strip off and then on again.
Is the power strip getting power?
Yes. Go to step 5.
No. Go to step 3.
3.
Plug the power strip into another electrical outlet.
Is the power strip getting power?
Yes. The original electrical outlet probably does not
function. Use a different electrical outlet.
No. Go to step 4.
4.
Plug a lamp that you know works into the electri-
cal outlet.
Does the lamp get power?
Yes. The power strip is probably not functioning
properly. Get another power strip.
No. Go to step 5.
5.
Reconnect the system to AC power.
Make sure that all connections fit tightly together.
6.
Turn on the system.
Is the problem resolved?
Yes. The connections were loose. You have fixed the
problem.
No. Go to step 7.
7.
Is your monitor operating properly?
Yes. Go to step 8.
No. Go to “Troubleshooting the Monitor” in Chap-
ter 5.
8.
Is your keyboard operating properly?
Yes. Go to step 9.
No. Go to “Troubleshooting the Keyboard” in Chap-
ter 5.
9.
Is your mouse or printer operating properly?
Yes. Continue with “Look and Listen” found next in
this chapter.
No. Go to “Troubleshooting I/O Ports” in Chapter 5.
Checking the Basics
1-3
Look and Listen
Looking at and listening to your system is important in
determining the source of a problem. Look and listen for
the indications described in Table 1-1.
If after looking and listening to your computer you have
not resolved the problem, continue with “The System
Setup Program” found next in this chapter.
Table 1-1. Boot Routine Indications
Look/Listen for:
Action
An error message
If your system documentation contains an appendix titled “Beep Codes and System
Messages,” see that appendix. Otherwise, see Chapter 2, “Messages and Codes,” in
this guide.
The monitor’s power
indicator
Most monitors have a power indicator (usually on the front bezel). If the monitor’s
power indicator does not light up, see “Troubleshooting the Monitor” in Chapter 5.
The keyboard indicators
Most keyboards have one or more indicators (usually in the upper-right corner).
Press the key, the key, and the key to tog-
gle the keyboard indicators on and off. If the keyboard indicators do not light up, see
“Troubleshooting the Keyboard” in Chapter 5.
The diskette-drive access
indicator
The diskette-drive access indicator should quickly flash on and off when you access
data on the diskette drive. On a system running a Microsoft® Windows® operating
system, you can test the drive by opening Windows Explorer (in Windows 95 or
Windows NT® 4.0) or File Manager (in Windows 3.x or Windows NT 3.51) and
clicking on the icon for drive A. On a system running MS-DOS, you can test the
drive by inserting a diskette into the drive, typing dir a:, and pressing .
If the diskette-drive access indicator does not light up, see “Troubleshooting the
Diskette/Tape Drive Subsystem” in Chapter 6.
The hard-disk drive access
indicator
The hard-disk drive access indicator should quickly flash on and off when you access
data on the hard-disk drive. On a system running a Windows operating system, you can
test the drive by opening Windows Explorer (in Windows 95 or Windows NT 4.0) or
File Manager (in Windows 3.x or Windows NT 3.51) and clicking on the icon for drive
C. On a system running MS-DOS, you can test the drive by typing dir c: and
pressing . If the hard-disk drive access indicator does not light up, see
“Troubleshooting Hard-Disk Drives” in Chapter 6.
A series of beeps
If your system documentation contains an appendix titled “Beep Codes and System
Messages,” see that appendix. Otherwise, see Chapter 2, “Messages and Codes,” in
this guide.
An unfamiliar constant scrap-
ing or grinding sound when
you access a drive
Make sure the sound is not caused by the application program you are running. The
sound could be caused by a hardware malfunction. See Chapter 7, “Getting Help,”
for instructions on getting technical assistance from Dell.
The absence of a familiar
sound
When you turn on your system, you can hear the hard-disk drive spin up, and the sys-
tem tries to access the boot files from the hard-disk drive or the diskette drive. If your
system boots, see Chapter 4, “Running the Dell Diagnostics.” If your system does
not boot, see Chapter 7, “Getting Help.”
Diagnostics and Troubleshooting Guide
The System Setup Program
You can easily correct certain system problems by verify-
ing the correct settings in the System Setup program.
When you boot your system, your system checks the sys-
tem configuration information and compares it with the
current hardware configuration. If your system hardware
configuration doesn’t match the information recorded by
the System Setup program, an error message may appear
on your screen.
This problem can happen if you changed your system’s
hardware configuration and forgot to run the System
Setup program. To correct this problem, enter the System
Setup program, correct the corresponding System Setup
program category, and reboot your system. See your sys-
tem documentation for detailed instructions on using the
System Setup program.
If after checking the settings in the System Setup pro-
gram you have not resolved the problem, determine
whether you have an EISA system. If you have an EISA
system, see “The EISA Configuration Utility” found next
in this chapter. If you do not have an EISA system, see
Chapter 4, “Running the Dell Diagnostics.”
The EISA Configuration Utility
If you have a system that can use EISA expansion cards,
and if you are experiencing problems with your system,
you may have a conflict between the information stored
by the System Setup program and the EISA Configura-
tion Utility. Although the EISA Configuration Utility can
read changes from the System Setup program, the change
is not recorded into EISA configuration memory until
you run the EISA Configuration Utility and save the new
information. See your system documentation for detailed
instructions on using the EISA Configuration Utility and
saving new information.
If after using the EISA Configuration Utility you have
not resolved the problem, see Chapter 4, “Running the
Dell Diagnostics.”
Messages and Codes
2-1
Chapter 2
Messages and Codes
Your application programs, operating system, and the
computer itself are capable of identifying problems and
alerting you to them. When a problem occurs, a message
may appear on your monitor screen, or a beep code may
sound.
Several different types of messages can indicate when
your system is not functioning properly:
•
System messages
•
System beep codes
•
Warning messages
•
Diagnostics messages
This chapter describes each type of message and lists the
possible causes and actions you can take to resolve any
problems indicated by a message. To determine what
type of message you have received, read the following
sections.
NOTE: If your system documentation contains an appen-
dix titled “Beep Codes and System Messages,” refer to
that appendix rather than this chapter for the beep codes
and system messages produced by your system.
System Messages
System messages are generated by your computer. They
alert you to a possible operating problem or to a conflict
between your software and hardware. If you receive a
system message, see Table 2-1 for suggestions on resolv-
ing any problems indicated by the message. The system
messages are listed alphabetically. If you have a Dell
PowerEdge® system, refer to the chapter titled
“Messages and Codes” in your Installation and Trouble-
shooting Guide.
NOTE: If the system message you received is not listed in
the appropriate table, check the documentation for the
application program that you were running at the time
the message appeared and/or the operating system docu-
mentation for an explanation of the message and a
recommended action.
Table 2-1. System Messages
Message
Cause
Action
Address mark
not found
The BIOS found a faulty disk sector
or could not find a particular disk
sector.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Attachment
failed to
respond
The diskette drive or hard-disk drive
controller cannot send data to the
associated drive.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Diagnostics and Troubleshooting Guide
Bad command or
file name
The command you entered does not
exist or is not in the pathname you
specified.
Make sure you have spelled the command cor-
rectly, placed spaces in the proper location, and
used the correct pathname.
Bad error-
correction
code(ECC) on
disk read
Controller has
failed
The diskette drive or hard-disk drive
controller detected an uncorrectable
read error.
The hard-disk drive or the associated
controller is defective.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Data error
The diskette or hard-disk drive can-
not read the data.
Run the ScanDisk utility in the Microsoft Win-
dows 95 operating system or the chkdsk utility in
MS-DOS to check the file structure of the diskette
or hard-disk drive. See your operating system doc-
umentation for more information.
If you are using another operating system, run the
appropriate utility to check the file structure of the
diskette or hard-disk drive. See your operating sys-
tem documentation.
Decreasing
available
memory
One or more SIMMs or DIMMs may
be faulty or improperly seated.
See “Troubleshooting System Memory” in
Chapter 6.
Diskette drive 0
seek failure
Diskette drive 1
seek failure
A cable may be loose, or the system
configuration information may not
match the hardware configuration.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Diskette read
failure
A cable may be loose, or the diskette
may be faulty.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Diskette
subsystem reset
failed
The diskette drive controller may be
faulty.
Run the Diskette Drive(s) Test in the Dell
Diagnostics. See Chapter 4, “Running the Dell
Diagnostics.”
Drive not ready
No diskette is in the drive. The opera-
tion requires a diskette in the drive
before it can continue.
Put a diskette in the drive or close the drive latch.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Messages and Codes
2-3
Diskette write
protected
The diskette write-protect feature is
activated.
Remove the diskette from drive A and move the
write-protect tab to the unlocked position.
Gate A20
failure
One or more SIMMs or DIMMs may
be loose.
See “Troubleshooting System Memory” in
Chapter 6.
General
failure
The operating system is unable to
carry out the command.
This message is usually followed by specific infor-
mation—for example, PRINTER OUT OF
PAPER. Respond by taking the appropriate action.
Hard disk
configuration
error
The hard-disk drive failed
initialization.
See “Troubleshooting Hard-Disk Drives” in
Chapter 6.
Hard disk
controller
failure
Hard disk
failure
Hard-disk drive
read failure
The hard-disk drive failed
initialization.
See “Troubleshooting Hard-Disk Drives” in
Chapter 6.
Incompatible
Processor: CPU0
is B0
step or below!
Incompatible
Processor: CPU1
is B0
step or below!
An old, unsupported version of the
microprocessor is installed.
In a single-microprocessor system,
CPU0 refers to the system board
microprocessor; in a dual-
microprocessor system, it refers to
the secondary microprocessor on the
add-in card.
The CPU1 message appears only on
a dual-microprocessor system and
always refers to the system board
microprocessor.
Replace the indicated microprocessor with a cur-
rent version of the microprocessor. If you need
technical assistance, see Chapter 7, “Getting
Help.”
NOTE: These messages indicate a fatal error.
When a fatal error occurs, the system usually can-
not be rebooted until an appropriate hardware
change has been made.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Diagnostics and Troubleshooting Guide
Incompatible
Processors:
Cache sizes
different!
This message appears for a dual-
processor system if both processors
do not have the same-size level-2
cache.
Replace one of the microprocessors to make the
level-2 cache sizes match. If you need technical
assistance, see Chapter 7, “Getting Help.”
NOTE: This message indicates a fatal error. When
a fatal error occurs, the system usually cannot be
rebooted until an appropriate hardware change
has been made.
Invalid
configuration
information -
please run
SETUP program
The system configuration informa-
tion does not match the hardware
configuration.
Enter the System Setup program and correct the
system configuration information. See your system
documentation for instructions.
Keyboard clock
line failure
Keyboard
controller
failure
Keyboard data
line failure
Keyboard
failure
Keyboard stuck
key failure
A cable or connector may be loose,
or the keyboard or keyboard/mouse
controller may be faulty.
See “Troubleshooting the Keyboard” in Chapter 5.
Memory address
line failure at
address, read
value
expecting value
One or more SIMMs may be faulty
or improperly seated.
See “Troubleshooting System Memory” in
Chapter 6.
Memory
allocation
error
The software you are attempting to
run is conflicting with the operating
system or another application pro-
gram or utility.
Turn off the computer, wait 30 seconds, and then
turn it on. Try to run the program again. If the
problem persists, contact the software company.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Messages and Codes
2-5
Memory data
line failure
at address, read
value
expecting value
Memory double
word logic
failure at
address, read
value
expecting value
Memory odd/even
logic failure
at address, read
value
expecting value
Memory parity
failure at
address, read
value
expecting value
Memory write/
read failure
at address, read
value
expecting value
One or more SIMMs or DIMMs may
be faulty or improperly seated.
See “Troubleshooting System Memory” in
Chapter 6.
Memory size in
CMOS invalid
The amount of memory recorded in
the system configuration informa-
tion does not match the memory
installed in the computer.
Reboot the computer. If the error appears again,
see Chapter 7, “Getting Help,” for instructions on
obtaining technical assistance.
Memory tests
terminated by
keystroke
The memory test did not complete.
Rerun the memory test.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Diagnostics and Troubleshooting Guide
No boot device
available
The computer cannot find the dis-
kette or hard-disk drive.
Enter the System Setup program, check the system
configuration information for the diskette and
hard-disk drive, and if necessary, correct the infor-
mation. See your system documentation for
instructions.
No boot
sector on hard-
disk drive
The system configuration informa-
tion in the System Setup program
may be incorrect, or the operating
system may be corrupted.
Enter the System Setup program, check the system
configuration information for the hard-disk drive,
and if necessary, correct the information. See your
system documentation for instructions.
If the message persists, reinstall your operating
system. See the documentation that came with
your operating system.
No timer tick
interrupt
A chip on the system board might be
malfunctioning.
Run the System Set Test Group in the Dell
Diagnostics. See Chapter 4, “Running the Dell
Diagnostics.”
Non-system disk
or disk error
The diskette in drive A or your hard-
disk drive does not have a bootable
operating system installed on it.
A nonbootable diskette is in drive A. Either replace
the diskette with one that has a bootable operating
system, or remove the diskette from drive A and
restart the computer.
Not a boot
diskette
There is no operating system on the
diskette.
Boot the computer with a diskette that contains an
operating system.
Plug and Play
Configuration
Error
The system has encountered a prob-
lem in trying to configure one or
more expansion cards.
Run the ISA Configuration Utility to verify that all
ISA expansion cards are configured correctly (see
the chapter titled “Using the ISA Configuration
Utility” or the chapter titled “Using Configuration
Software” in your system documentation. If run-
ning the ISA Configuration Utility does not reveal
the source of the problem, see “Troubleshooting
Expansion Cards” in Chapter 6 of this guide.
Read fault
Requested sec-
tor not found
The operating system cannot read
from the diskette or hard-disk drive.
The system could not find a particu-
lar sector on the disk, or the
requested sector is defective.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Messages and Codes
2-7
Reset failed
The disk reset operation failed.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Sector not
found
The operating system is unable to
locate a sector on the diskette or
hard-disk drive.
See “Troubleshooting Hard-Disk Drives” or
“Troubleshooting the Diskette/Tape Drive Sub-
system” in Chapter 6, depending on what type of
drive you are accessing.
Seek error
The operating system is unable to
find a specific track on the diskette or
hard-disk drive.
If the error is on the diskette drive, try another
diskette in the drive.
Shutdown
failure
A chip on the system board might be
malfunctioning.
Run the System Set Test Group in the Dell
Diagnostics. See Chapter 4, “Running the Dell
Diagnostics.”
Terminator/
processor
card cannot
be installed!
Neither a terminator card nor a sec-
ondary microprocessor card is
installed in the secondary micropro-
cessor card connector (2ND_CPU).
Make sure either a terminator card or a secondary
microprocessor card is installed in the 2ND_CPU
connector. Reseat the card and start the system. If
errors persist, see Chapter 7, “Getting Help,” for
instructions on obtaining technical assistance.
NOTE: This message indicates a fatal error. When
a fatal error occurs, the system usually cannot be
rebooted until an appropriate hardware change
has been made.
Time-of-day
clock stopped
The battery may be dead.
Enter the System Setup program and correct the
date or time. See your system documentation for
instructions.
If the problem persists, see “Troubleshooting the
Battery” in Chapter 6.
Time-of-day not
set
The time or date displayed in the sys-
tem configuration information does
not match the system clock.
Enter the System Setup program and correct the
date or time. See your system documentation for
instructions.
Timer chip
counter 2
failed
A chip on the system board might be
malfunctioning.
Run the System Set Test Group in the Dell
Diagnostics. See Chapter 4, “Running the Dell
Diagnostics.”
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Diagnostics and Troubleshooting Guide
Unexpected
interrupt in
protected mode
The keyboard controller may be mal-
functioning, or one or more SIMMs
or DIMMs may be loose.
Run the RAM Test Group and the Keyboard Con-
troller Test in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
WARNING: Dell’s
Disk Monitor-
ing System has
detected that
drive [0/1] on
the
[primary/
secondary] EIDE
controller is
operating
outside of nor-
mal
specifica-
tions. It is
advisable to
immediately
back up your
data and
replace your
hard-disk drive
by calling your
support desk or
Dell Computer
Corporation.
POST has queried the EIDE drive for
status information. The drive has
returned a parameter from the call
that indicates it has detected possible
error conditions for its operating
specifications.
Once your computer finishes booting, immediately
back up your data and replace your hard-disk
drive. Restore the data to the replaced drive.
If a replacement drive is not immediately available
and the drive is not the only bootable drive, enter
the System Setup program and change the appro-
priate drive setting to None. Remove the drive
from the system. This should be done only after
you have backed up the data.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Messages and Codes
2-9
System Beep Codes
When errors occur during a boot routine that cannot be
reported on the monitor, your computer may emit a series
of beeps that identify the problem. The beep code is a
pattern of sounds: for example, one beep, followed by a
second beep, and then a burst of three beeps (code 1-1-3)
means that the computer was unable to read the data in
nonvolatile random-access memory (NVRAM). This
information is invaluable to the Dell support staff if you
need to call for technical assistance.
Warning -
Thermal Probes
failed.
At system start-up, the BIOS has
detected that one or both of the
thermal probes in the computer are
nonoperational.
You can continue to use the system, but be aware
that the temperature probe(s) are disabled and a
processor overheat condition will not warn the
Thermal Shutdown service to shut down the
system.
NOTE: The Pentium® Pro microprocessor has a
built-in thermocouple that halts microprocessor
operation if the microprocessor exceeds its rated
temperature.
To correct this problem, you must replace your
system board. For technical assistance, see
Chapter 7, “Getting Help.”
Warning -
Temperature
is too high.
At system start-up, the BIOS has
detected that one or both microproces-
sors are overheated. After displaying
this message, the BIOS halts the pro-
cesses and turns off the system.
Let the system cool down before attempting to
restart it.
Write fault
Write fault on
selected drive
The operating system cannot write to
the diskette or hard-disk drive.
See “Troubleshooting the Diskette/Tape Drive
Subsystem” in Chapter 6.
Table 2-1. System Messages (continued)
Message
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Diagnostics and Troubleshooting Guide
When a beep code is emitted, write it down on a copy of
the Diagnostics Checklist found in Chapter 7, “Getting
Help,” and then look it up in Table 2-2. If you are unable
to resolve the problem by looking up the meaning of the
beep code, use the Dell Diagnostics to identify a more
serious cause. If you are still unable to resolve the prob-
lem, see Chapter 7, “Getting Help,” for instructions on
obtaining technical assistance.
Table 2-2. System Beep Codes
Code
Cause
Action
1-1-2
Microprocessor register
failure
See Chapter 7, “Getting Help,” for instructions on obtaining technical
assistance.
1-1-3
NVRAM
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
1-1-4
ROM BIOS checksum
failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-2-1
Programmable interval timer
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-2-2
DMA initialization failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-2-3
DMA page register read/
write failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-3
Video Memory Test failure
Run the Video Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
1-3-1
through
2-4-4
SIMMs or DIMMs not being
properly identified or used
See “Troubleshooting System Memory” in Chapter 7.
3-1-1
Slave DMA register failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
3-1-2
Master DMA register failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
3-1-3
Master interrupt mask
register failure
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
3-1-4
Slave interrupt mask
register failure
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
3-2-2
Interrupt vector loading
failure
See Chapter 7, “Getting Help,” for instructions on obtaining technical
assistance.
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Messages and Codes
2-11
3-2-4
Keyboard Controller Test
failure
Run the Keyboard Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.” Otherwise, see Chapter 7, “Getting
Help,” for instructions on obtaining technical assistance.
3-3-1
NVRAM power loss
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
3-3-2
NVRAM configuration
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
3-3-4
Video Memory Test failure
Run the Video Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
3-4-1
Screen initialization failure
Run the Video Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
3-4-2
Screen retrace failure
Run the Video Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
3-4-3
Search for video ROM
failure
Run the Video Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
4-2-1
No time tick
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
4-2-2
Shutdown failure
See Chapter 7, “Getting Help,” for instructions on obtaining technical
assistance.
4-2-3
Gate A20 failure
See Chapter 7, “Getting Help,” for instructions on obtaining technical
assistance.
4-2-4
Unexpected interrupt in pro-
tected mode
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
4-3-1
Memory failure above
address 0FFFFh
Run the RAM Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
4-3-3
Timer-chip counter 2 failure
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
4-3-4
Time-of-day clock stopped
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
4-4-1
Serial or parallel port test
failure
Run the Serial/Infrared Port Test Group and the Parallel Port Test Group
in the Dell Diagnostics. See Chapter 4, “Running the Dell Diagnostics.”
Table 2-2. System Beep Codes (continued)
Code
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Diagnostics and Troubleshooting Guide
4-4-2
Failure to decompress code
to shadowed memory.
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
4-4-3
Math-coprocessor test failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
4-4-4
Cache test failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
5-1-2
BIOS update error—no
RAM in system
See “Troubleshooting System Memory” in Chapter 6.
5-1-3
BIOS update error—exter-
nal video card detected
If a video expansion card is installed, disconnect the video expansion
card and connect the monitor to the built-in video subsystem. If the prob-
lem is not resolved, see “Troubleshooting the Video Subsystem” in
Chapter 6.
5-1-4
BIOS execution error
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
6-1-2
I/O controller failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
6-1-3
Keyboard controller failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
6-1-4
CMOS Register Test failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
6-2-1
BIOS shadowing failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
6-2-2
Pentium speed determina-
tion failure
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
6-2-3
No SIMM or DIMM
installed
See “Troubleshooting System Memory” in Chapter 6.
Table 2-2. System Beep Codes (continued)
Code
Cause
Action
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Messages and Codes
2-13
Warning Messages
A warning message alerts you to a possible problem and
asks you to do something before execution continues. For
example, before you format a diskette, a message may
warn you that you may lose all data on the diskette as a
way to protect against inadvertently erasing or writing
over the data. These warning messages usually interrupt
the procedure and require you to respond by typing a y
(yes) or n (no).
NOTE: Warning messages are generated by either your
application programs or your operating system. See
Chapter 3, “Finding Software Solutions,” and the docu-
mentation that accompanied your operating system and
application programs.
Diagnostics Messages
When you run a test group or subtest in the Dell Diagnos-
tics, an error message may result. These particular error
messages are not covered in this chapter. Record the mes-
sage on a copy of your Diagnostics Checklist found in
Chapter 7, “Getting Help.” Also see Chapter 7 for
instructions on obtaining technical assistance.
Finding Software Solutions
3-1
Chapter 3
Finding Software Solutions
Because most computers have several application
programs installed in addition to the operating system,
isolating a software problem can be confusing. Software
errors can also appear to be hardware malfunctions at
first. Software problems can result from the following
circumstances:
•
Improper installation or configuration of a program
•
Input errors
•
Device drivers that may conflict with certain appli-
cation programs
•
Memory conflicts resulting from the use of
terminate-and-stay-resident (TSR) programs
•
Interrupt conflicts between devices
You can confirm that a computer problem is caused by
software by running the System Set Test Group as
described in Chapter 4, “Running the Dell Diagnostics.”
If all tests in the test group complete successfully, the
error condition is most likely caused by software.
This chapter provides some general guidelines for ana-
lyzing software problems. For detailed troubleshooting
information on a particular program, see the documenta-
tion that accompanied the software or consult the support
service for the software.
Installing and Configuring
Software
When you obtain software, check it for viruses with
virus-scanning software before installing it on your com-
puter’s hard-disk drive. Viruses, which are pieces of code
that can replicate themselves, can quickly use all avail-
able system memory, damage and/or destroy data stored
on the hard-disk drive, and permanently affect the
performance of the programs they infect. Several com-
mercial virus-scanning programs are available for
purchase, and most bulletin board services (BBSs)
archive freely distributed virus-scanning programs that
you can download with a modem.
Before installing a program, read its documentation to
learn how the program works, what hardware it requires,
and what its defaults are. A program usually includes
installation instructions in its accompanying documenta-
tion and a software installation routine on its program
diskettes.
The software installation routine assists you in transfer-
ring the appropriate program files to your computer’s
hard-disk drive. Installation instructions may provide
details about how to configure your operating system to
successfully run the program. Always read the installa-
tion instructions before running a program’s installation
routine. You may be instructed to modify some operating
system start-up files, such as config.sys and
autoexec.bat, or the installation routine may modify
start-up files automatically.
When you run the installation routine, be prepared to
respond to prompts for information about how your com-
puter’s operating system is configured, what type of
computer you have, and what peripherals are connected
to your computer.
Expanded and Extended Memory
Depending on which Dell computer you have, the system
memory can be expanded by installing additional single
in-line memory modules (SIMMs) or dual in-line mem-
ory modules (DIMMs) or by exchanging installed
SIMMs or DIMMs for ones of larger capacity. If you
operate your computer with MS-DOS, the operating sys-
tem makes only 640 kilobytes (KB) (called conventional
memory) of the first 1 megabyte (MB) of system memory
Diagnostics and Troubleshooting Guide
available for use by application programs. Some pro-
grams require more than 640 KB of memory and,
therefore, cannot be run with conventional memory
alone. Other programs run much faster when they have
more than 1 MB of memory to use.
When you boot your computer, MS-DOS recognizes
memory in excess of 1 MB as extended memory. Some,
but not all, programs are able to use extended memory.
For example, the Microsoft Windows 3.x operating sys-
tem and Lotus® 1-2-3 take advantage of extended
memory.
Other programs are able to use extended memory only if
it is first converted into expanded memory by an
expanded memory manager (EMM).
NOTE: Not all Dell computers have an EMM driver. See
your system documentation to determine whether an
EMM driver is provided with your system.
Under the following conditions, expanded memory can
greatly enhance the system’s ability to use application
programs that require more memory than is available in
the conventional memory area:
•
The application program is written for use with
expanded memory.
•
The memory has been properly allocated using the
System Setup program. (See your system documen-
tation for more information on the System Setup
program.)
•
The EMM driver is installed and properly initialized.
Improper use of an EMM can lead to conflicts between
the expanded-memory operation and any installed expan-
sion cards, which may be assigned memory areas that
overlap memory areas that the EMM is using. For more
information about these types of conflicts and how to
avoid them, see “Checking for Memory Address Con-
flicts” found later in this chapter.
Using Software
The following subsections discuss errors that can occur
as a result of software operation or configuration.
Error Messages
Error messages can be produced by an application pro-
gram, the operating system, or the computer. Chapter 2,
“Messages and Codes,” discusses the error messages that
are generated by the system. If you receive an error mes-
sage that is not listed in Chapter 2, check your operating
system or application program documentation.
Input Errors
If a specific key or set of keys is pressed at the wrong
time, a program may give you unexpected results. See the
documentation that came with your application program
to make sure the values or characters you are entering are
valid.
Make sure the operating environment is set up to
accommodate the programs you use. Keep in mind that
whenever you change the parameters of the computer’s
operating environment, you may affect the successful
operation of your programs. Sometimes, after modifying
the operating environment, you may need to reinstall a
program that no longer runs properly.
Memory-Resident Programs
There are a variety of utilities and supplementary pro-
grams that can be loaded either when the computer boots
or from an operating system prompt. These programs are
designed to stay resident in system memory and thus
always be available for use. Because they remain in the
computer’s memory, memory conflicts and errors can
result when other programs require use of all or part of
the memory already occupied by these TSR programs.
Typically, your operating system’s start-up files (such as
config.sys and autoexec.bat) contain commands to start
TSR programs when you boot your system. If you sus-
pect that one of these TSR programs is causing a memory
conflict, remove the commands that start them from the
start-up file. If the problem you were experiencing does
not recur, one of the TSR programs probably created the
conflict. Add the TSR commands back into the start-up
files one at a time until you identify which TSR program
is creating the conflict.
Finding Software Solutions
3-3
Program Conflicts
Some programs may leave portions of their setup infor-
mation behind, even though you have exited from them.
As a result, other programs cannot run. Rebooting your
system can confirm whether or not these programs are
the cause of the problem.
There are also programs that use specialized subroutines
called device drivers that can also cause problems with
your computer system. For example, a variation in the
way the data is sent to the monitor may require a special
screen driver program that expects a certain kind of video
mode or monitor. In such cases, you may have to develop
an alternative method of running that particular pro-
gram—the creation of a boot file made especially for that
program, for example. Call the support service for the
software you are using to help you with this problem.
Checking for Memory Address Conflicts
Memory address conflicts occur when two or more
devices try to access the same address in the upper mem-
ory block (UMB). For example, if a network expansion
card and an expanded-memory page frame are assigned
an overlapping block of addresses, a memory address
conflict arises. As a result, when you try to log into the
network, the operation fails.
To resolve this type of conflict, you can change the
address of one of the devices. For example, in the case of
the network expansion card and expanded-memory page-
frame address conflict, you can move the network card to
an address block in the range of CC000h through
D0000h. To reassign the expansion card’s address block,
refer to the documentation for the card.
Avoiding Interrupt Assignment
Conflicts
Problems can arise if two devices attempt to use the same
interrupt request (IRQ) line. To avoid this type of con-
flict, check the documentation for the default IRQ line
setting for each installed expansion card. Then consult
Table 3-1 to configure the card for one of the available
IRQ lines.
NOTE: Table 3-1 lists default IRQ settings. In systems
with Plug and Play capabilities, the default settings can
be modified. If you are installing a Plug and Play card in
a Plug and Play system, the system will automatically
select an open IRQ line if any are available. If you are
installing a non-Plug and Play or legacy card, run the
ISA Configuration Utility provided with your system to
determine the current IRQ settings and to find an avail-
able IRQ line. For instructions, see the ISA
Configuration Utility chapter in your system
documentation.
Table 3-1. Default IRQ Line Assignments
IRQ Line
Used/Available
IRQ0
Used by the system timer
IRQ1
Used by the keyboard to signal that the
output buffer is full
IRQ2
Used by interrupt controller 1 to enable
IRQ8 through IRQ15
IRQ3
Used by serial port 2
IRQ4
Used by serial port 1
IRQ5
Available
IRQ6
Used by the diskette/tape drive
controller
IRQ7
Used by the parallel port
IRQ8
Used by the RTC
IRQ9
Used by the VGA interface (optional)
IRQ10
Available
IRQ11
Available
IRQ12
Used by the mouse port
IRQ13
Used by the math coprocessor (if
applicable)
IRQ14
Used by the primary IDE controller
IRQ15
Used by the secondary IDE controller
NOTE: For the full name of an abbreviation or acronym used
in this table, see the abbreviation and acronym list that pre-
cedes the Index.
Running the Dell Diagnostics
4-1
Chapter 4
Running the Dell Diagnostics
Unlike many diagnostic programs, the Dell Diagnos-
tics helps you check your computer’s hardware without
any additional equipment and without destroying any
data. By using the diagnostics, you can have confidence
in your computer system’s operation. And if you find a
problem you cannot solve by yourself, the diagnostic
tests can provide you with important information you
will need when talking to Dell’s service and support
personnel.
Features of the Dell Diagnostics
The Dell Diagnostics provides a series of menus and
options from which you choose particular test groups or
subtests. You can also control the sequence in which the
tests are run. The diagnostic test groups or subtests also
have these helpful features:
•
Options that let you run tests individually or
collectively
•
An option that allows you to choose the number of
times a test group or subtest is repeated
•
The ability to display or print out test results, or to
save them in a file
•
Options to temporarily suspend testing if an error is
detected, or to terminate testing when an adjustable
error limit is reached
•
A menu category called About that briefly describes
each test and its parameters
•
Status messages that inform you whether test groups
or subtests were completed successfully
•
Error messages that appear if any problems are
detected
When to Use the Dell
Diagnostics
Whenever a major component or device in your com-
puter system does not function properly, you may have a
component failure. As long as the microprocessor and the
input and output components of your computer system
(the monitor, keyboard, and diskette drive) are working,
you can use the Dell Diagnostics. If you are experienced
with computers and know what component(s) you need
to test, simply select the appropriate diagnostic test
group(s) or subtest(s). If you are unsure about how to
begin diagnosing a problem, read the rest of this chapter.
Before You Start Testing
Follow these steps to create a master and/or working
copy of the Dell Diagnostics Diskette.
1.
If you received a Dell Diagnostics Diskette with
your Dell system, go to step 4.
CAUTION: Use the Dell Diagnostics to test only
your Dell computer system. Using this program
with other computers may cause incorrect com-
puter responses or result in error messages.
Diagnostics and Troubleshooting Guide
2.
If you did not receive a Dell Diagnostics Diskette,
a diskette image has been installed on your
computer’s hard-disk drive so that you can make
your own copy of the diskette.
If Dell installed the Microsoft Windows 3.x or
Windows 95 operating system on your computer’s
hard-disk drive, see the online help in Dell’s Pro-
gram Diskette Maker utility, which is available in the
Dell Accessories group or folder, for instructions on
making a program diskette set from the diskette
image.
If Dell installed MS-DOS, but not Windows, on your
computer’s hard-disk drive, see the Dell Menu,
which appears when you first turn on your system,
for instructions on making a program diskette set
from the diskette image.
3.
Using a felt-tip pen, write “Dell Diagnostics Dis-
kette” on the diskette label.
4.
Make a working copy of the Dell Diagnostics Dis-
kette on a blank diskette.
Refer to your operating system’s documentation for
information on how to duplicate diskettes. Put the
original diskette away for safekeeping.
5.
Turn on your printer if one is attached, and make
sure it is online.
6.
Enter the System Setup program, confirm your
computer’s system configuration information,
and enable all its components and devices, such as
ports.
For instructions on entering and using the System
Setup program, see your system documentation.
Starting the Dell Diagnostics
After you complete the preliminary instructions specified
in the previous section, follow these steps to start the
diagnostics:
1.
Turn off the computer.
2.
Place your diagnostics diskette in drive A, and
boot the system.
NOTE: Before you read the rest of this chapter, you may
want to start the Dell Diagnostics so that you can see it
on the screen of your monitor.
When you start the diagnostics, the Dell logo screen
appears, followed by a message telling you that the diag-
nostics is loading.
After the diagnostics loads, the Diagnostics Menu
appears. The menu allows you to run all or specific diag-
nostic tests or to exit to the MS-DOS prompt.
For a quick check of your system, select the Run Quick
Tests option. This option runs only the subtests that do
not require user interaction and that do not take a long
time to run. Dell recommends that you choose this option
first to increase the odds of tracing the source of the prob-
lem quickly. For a thorough check of your system, select
the Run All Tests option. To check a particular area of
your system, select the Run Specific Tests option.
To select an option from this menu, highlight the option
and press , or press the key that corresponds to
the highlighted letter in the option you choose.
Running the Dell Diagnostics
4-3
Figure 4-1. Diagnostics Menu
How to Use the Dell Diagnostics
When you select Run Specific Tests from the Diagnostics
Menu, the main screen of the diagnostics appears (see
Figure 4-2). The main screen lists the diagnostic test
groups, gives information about the configuration of your
computer system, and allows you to select categories
from a menu. From this screen, you can enter two other
types of screens.
Information on the main screen of the diagnostics is pre-
sented in the following five areas:
•
Two lines at the top of the screen identify the version
number of the Dell Diagnostics.
•
On the left side of the screen, the Available Test
Group area lists the diagnostic test groups in the
order they will run if you select All from the Run
menu category. Press the up- or down-arrow key to
highlight a test group.
•
On the right side of the screen, the System Configu-
ration area lists the computer’s currently detected
hardware and some of the relevant settings.
•
The lower-right side of the screen displays informa-
tion about your integrated drive electronics (IDE)
hard-disk and CD-ROM drive(s).
•
Two lines at the bottom of the screen make up the
menu area. The first line lists the categories you can
select; press the left- or right-arrow key to highlight
a menu category. The second line gives information
about the category currently highlighted.
Dell Computer Corporation
Dell System Diagnostics Version X.XX
Run All Tests
RUn Quick Tests
RuN Specific Tests
Exit To MS-DOS
Diagnostics Menu
Diagnostics and Troubleshooting Guide
Figure 4-2. Dell Diagnostics Screen
Confirming the System Configu-
ration Information
When you boot your system from your diagnostics dis-
kette, the diagnostics checks your system configuration
information and displays it in the System Configuration
area on the main screen.
The following sources supply this configuration informa-
tion for the diagnostics:
•
The system configuration information settings
(stored in nonvolatile random-access memory
[NVRAM]) that you selected while using the System
Setup program
•
Identification tests of the microprocessor, the video
controller, the keyboard controller, and other key
components
•
Basic input/output system (BIOS) configuration
information temporarily saved in RAM
Do not be concerned if the System Configuration area
does not list the names of all the components or devices
you know are part of your computer system. For
example, you may not see a printer listed, although you
know one is attached to your computer. Instead, the
printer is listed as a parallel port. The computer recog-
nizes the parallel port as LPT1, which is an address that
tells the computer where to send outgoing information
and where to look for incoming information. Because
RAM
System Set
Video
Keyboard
Mouse
Diskette Drives
Hard-Disk Drives (Non-SCSI)
IDE CD ROM Drives
Serial/Infrared Ports
Parallel Ports
SCSI Devices
Network Interface
Audio
Other
NOTE: The options displayed on your screen should reflect the hardware configuration of your computer system.
Dell Computer Corporation
Dell System Diagnostics Version X.XX
Memory
4 MB
Secondary Cache 128 KB
Processor(s)
Pentium
Video
SVGA,1024K
Keyboard
101 Key
Mouse PS/2 2-button
Diskette Drive(s)
A:1.4MB
IDE(0)524MB, 1016 Cyl, 16 Hd, 63 Sec
IDE(2) CDROM:
NEC CD-ROM DRIVE:260
Serial/IR Port(s)
2
Parallel Port(s)
1
Modems
None
SCSI Devices
2
Network Interface
None
Serial/IR Ports
Integrated
Audio
None
Embedded Server Management
System Configuration
Available Test Groups
Main Menu: Run seLect Subtest Options Test_limits About Key_help Quit
Display the Run Menu. Press Q to Quit
Running the Dell Diagnostics
4-5
your printer is a parallel communications device, the
computer recognizes the printer by its LPT1 address and
identifies it as a parallel port.
How to Use the Menu
One of the menu categories is already highlighted. You
can move the highlight from one category to another by
pressing the left- or right-arrow key. As you move from
one menu category to another, a brief explanation of the
currently highlighted category appears on the bottom line
of the screen.
If you want more information about a test group or sub-
test, move the highlight to the About category and press
. After reading the information, press the
key to return to the previous screen.
Main Menu Categories
Eight categories are listed in the Main menu of the diag-
nostics main screen: Run, Select, Subtest, Options, Test
Limits, About, Key-Help, and Quit.
NOTE: Before running any test groups or subtests (by
selecting Run), you should consider setting global
parameters within the Options category. They offer you
greater control over how the test groups or subtests are
run and how their results are reported.
There are two ways to select a menu category:
•
Look on the screen to see which letter in the category
is capitalized, and type that letter (for example, type
r to select the Run category).
•
Move the highlight to the category you wish to select
by pressing the left- or right-arrow key, and then
press .
Whenever one of the eight categories is selected, addi-
tional choices become available.
The following subsections explain the menu categories as
listed from left to right in the Main menu.
Run
Run displays five categories: One, Selected, All, Key-
Help, and Quit Menu. If you select One, all the subtests
within the highlighted test group are run. If you choose
Selected, only the selected test groups or the subtests that
you selected within the test groups are run. If you select
All, all of the subtests in all of the test groups are run.
(The test groups or subtests are run in the same order as
they are listed.)
The Key-Help category displays a list of key controls
available for the particular category you have chosen.
The Quit Menu category returns you to the Main menu.
Select
Select allows you to select individual test groups to tailor
the testing process to your particular needs. You can
choose one or more test groups and run them sequentially
or individually. When you choose Select, five categories
are displayed: All, One, Clear All, Key-Help, and Quit
Menu.
To select all the test groups, press the key when
All is highlighted in the Select menu.
To select an individual test group, highlight the test group
and press the or highlight One and press
. Press the up- or down-arrow key to change the
highlighted test group.
To reverse a test group selection, highlight the test group
and press the . To clear all selections, select
Clear All.
The Key-Help category displays a list of key controls
available for the particular category you have chosen.
The Quit Menu category returns you to the Main menu.
Subtest
Most of the test groups consist of several subtests. Use
the Subtest category to select individual subtests within
the test group(s).
When you select Subtest, many of the same categories as
those on the Main menu are displayed: Run, Select,
Options, Test Limits, About, Key-Help, and Quit Menu.
Each of these categories is explained in the following
subsections.
Diagnostics and Troubleshooting Guide
Run Under Subtest
Run in the Subtest menu displays five categories: One,
Selected, All, Key-Help, and Quit Menu. If you select
One, only the highlighted subtest is run. If you select
Selected, only the selected subtests are run. If you select
All, all of the subtests listed on the screen are run. (The
subtests are run in the same order as they are listed.)
The Key-Help category displays a list of key controls
available. The Quit Menu category returns you to the pre-
vious menu.
Select Under Subtest
Select in the Subtest menu allows you to select individual
subtests to tailor the testing process to your particular
needs. You can choose one or more subtests from the list.
When you choose Select, five categories are displayed:
All, One, Clear All, Key-Help, and Quit Menu.
To select all the subtests, press the key when All
is highlighted in the Select menu. To select an individual
subtest, highlight the subtest and press the or
highlight One and press . Press the up- or down-
arrow key to highlight a subtest to be selected.
To reverse a subtest selection, highlight the subtest and
press the . To clear all selections, select Clear
All.
The Key-Help category displays a list of key controls
available. The Quit Menu category returns you to the pre-
vious menu.
Options Under Subtest
The Options category in the Subtest menu functions the
same way as the Options category in the Main menu. For
information on this category, see “Options” found later in
this chapter.
Test Limits Under Subtest
The Test Limits category in the Subtest menu functions
the same way as the Test Limits category in the Main
menu. For information on this category, see “Test Limits”
found later in this chapter.
About Under Subtest
The About category in the Subtest menu displays infor-
mation about the highlighted subtest.
Key-Help Under Subtest
The Key-Help category in the Subtest menu displays a
list of key controls available.
Quit Menu Under Subtest
The Quit Menu category in the Subtest menu returns you
to the Main menu.
Options
Table 4-1 lists all of the possible values for each global
parameter of Options. A brief description of each param-
eter follows the table. To change Options parameters,
press the , the left- and right- arrow keys, or
the plus (+) and minus (-) keys.
Number of Times to Repeat Test(s)
This parameter specifies the number of times the tests run
when you select Run. To change the default, type in the
desired value. If you type 0 (zero), the tests will run
indefinitely.
Maximum Errors Allowed
This parameter specifies the maximum number of errors
that can occur before testing is stopped. The error count
begins from zero each time you run a subtest or test
group individually or each time you select All to run all
of them. To change the default, type in the desired value.
Running the Dell Diagnostics
4-7
If you type 0 (zero), you are specifying that there be no
limit on the number of errors that can occur—testing will
not be stopped, regardless of the number of errors.
Pause for User Response
If this parameter value is set to Yes, the diagnostics
pauses when one of the following occurs:
•
Your interaction is needed to verify the Video Test
Group screens or the Keyboard Test Group key func-
tions or other types of interaction such as inserting a
diskette.
•
The maximum error limit is reached.
If the Pause parameter is set to No, the diagnostics
ignores some subtests that require your interaction; cer-
tain subtests can run only if this option is set to Yes
because they require user interaction. Use the Pause
parameter in situations where you may want to prevent
subtests that require user interaction from running—such
as when you run the diagnostics overnight.
Output Device for Status Messages
Ordinarily, all status messages appear only on the screen.
This parameter allows you to direct status messages to
either a printer or a file, in addition to the screen. If you
choose the File option, status messages are written to a
file named result. This file is automatically created on a
diskette that you insert into drive A when prompted. If
you are running the diagnostics from a utility partition on
your hard-disk drive, the result file is created on the
hard-disk drive. If the result file already exists, new sta-
tus messages are added to it.
The result file is an ordinary American Standard Code
for Information Interchange (ASCII) text file that you
can open in any text viewer or word processor. You can
also access the result file with the MS-DOS type com-
mand as follows:
Table 4-1. Option Parameters
Option Limit
Possible Values
Number of Times to Repeat Test(s)
0001 through 9999, or 0000, which loops indefinitely until you press the
and keys. The default is 1.
Maximum Errors Allowed
0000 through 9999, where 0000 means that there is no error limit.
The default is 1.
Pause For User Response
Yes, No
Allows you to decide whether tests will wait for user input.
The default is Yes to wait for user input.
Output Device for Status Messages
Display, Printer, File
If you have a printer attached to your computer, you can use it to print the
status messages, if any, that are generated when a test runs. (The printer
must be turned on and in the online mode to print.) If you select File, the
messages are printed to a file named result on a diskette that you insert
into drive A when prompted. If you are running the diagnostics from a
utility partition on your hard-disk drive, the result file is created on the
hard-disk drive. The default is Display.
Output Device for Error Messages
Display, Printer, File
This parameter has the same effect as the Output Device for Status Mes-
sages parameter, except that it pertains only to error messages.
The default is Display.
Diagnostics and Troubleshooting Guide
1.
Select Quit to exit the diagnostics and return to
the operating system prompt.
2.
At the operating system prompt, type the appro-
priate command and press :
type result
The contents of the file appear on the screen.
After running particular diagnostic tests and viewing the
status messages generated by the tests in the result file,
you can erase the contents of the file so that it is clear for
the next set of messages generated. Otherwise, the next
messages are added at the end of the previous ones in the
file.
Output Device for Error Messages
Ordinarily, all error messages appear only on the screen.
This parameter allows you to direct error messages to
either a printer or a file, in addition to the screen. If you
choose the File option, error messages are written to the
result file used for status messages. This file is automati-
cally created on a diskette that you insert into drive A
when prompted. If you are running the diagnostics from a
utility partition on your hard-disk drive, the result file is
created on the hard-disk drive. If the result file already
exists, new error messages are added to it.
The result file is an ordinary ASCII text file. You can
access and review the result file as described in the pre-
vious subsection, “Output Device for Status Messages.”
After running particular diagnostic tests and viewing the
error messages generated by the tests in the result file,
you can erase the contents of the file so that it is clear for
the next set of messages generated. Otherwise, the next
messages are added at the end of the previous ones in the
file.
Test Limits
NOTE: The Dell Diagnostics sets default limits on all
tests. The only reason to change the default would be to
limit the amount of testing done.
The RAM Test Group, the Video Test Group, the Diskette
Drives Test Group, the Hard-Disk Drives (Non-SCSI)
Test Group, the Serial/Infrared Ports Test Group, the Par-
allel Ports Test Group, and the SCSI Devices Test Group
allow you to designate limits. Whether you select Test
Limits for a highlighted test group (from the Main menu)
or a subtest (from the Subtest menu), you set the limits
for all the subtests in that test group. When you select
Test Limits, a new screen appears and the Key-Help area
lists keys to use with the new screen. Press
to select the next menu or submenu. Press to
return to the main Test Limits window.
How you change a value for the limits of a test group or
subtest depends on the type of parameter associated with
it. Different keys are used to change values for different
types of parameters. For example, memory address limits
specified for the RAM Test Group are changed by typing
in numbers over the digits of a given limit or by pressing
the plus (+) or minus (-) keys to increase or decrease the
given limit. In contrast, to set limits for the Serial/
Infrared Ports Test Group, you use the to
toggle between Yes and No.
After you are satisfied with the limits, return to the Dell
Diagnostics main screen by pressing the key. The
values you selected under Test Limits remain in effect
during all the test groups or subtests you run, unless you
change them. However, the values are reset to their
defaults when you restart the diagnostics.
About
About in the Main menu lists all of the subtests for the
selected test group and displays information about the
subtest that is highlighted.
Key-Help
Key-Help always displays a list of key controls available
for the particular category you have selected.
Quit
Selecting Quit from the Main menu exits the diagnostics
and returns you to your operating system environment.
After you return to the operating system environment,
remove your diagnostics diskette from drive A and
reboot the computer.
CAUTION: It is important that you quit the diag-
nostics correctly because the program writes data
to the computer’s memory that can cause prob-
lems unless properly cleared.
Running the Dell Diagnostics
4-9
Tests in the Dell Diagnostics
To troubleshoot components or devices, run the appropri-
ate test (test group or subtest) in the diagnostics on your
diagnostics diskette. The diagnostics exercises the func-
tional components and devices of your computer system
more vigorously and thoroughly than they are exercised
during normal operation. The diagnostics is organized by
components into test groups and subtests within each test
group. Each subtest is designed to detect any errors that
may interfere with the normal operation of a specific
device of the computer.
NOTE: Some subtests requiring hardware not listed in
the System Configuration area of the diagnostics screen
appear to run, but they conclude with a status message
stating Component not present (or
disabled).
Table 4-2 lists the diagnostic test groups, their subtests,
and comments concerning their use.
Table 4-2. Dell Diagnostics Tests
Test Groups
Subtests
Description
RAM
Quick Memory Test
Comprehensive Memory Test
Secondary Cache Memory Test
Tests the RAM and cache. (Some computers include
expanded or extended memory; all memory is
tested.)
System Set
CMOS Confidence Test
CMEM Confidence Test
DMA Controller Test
Real-Time Clock Test
System Timers Test
Interrupt Controller Test
Reset Button Test
System Speaker Test
Coprocessor Calculation Test
Coprocessor Error Exception Test
PC Card Controller Test
Thermal Control Test
Multiprocessor Test
USB Register Test
USB Memory Structure Test
Tests the system board’s support chips, DMA con-
troller, computer timer, NVRAM, speaker controller,
cache, and EISA configuration RAM chip, as
appropriate.
Tests the math coprocessor that is internal to the
microprocessor.
Tests the PC Card controller on the system board.
Checks the functionality of the thermal-monitoring
and microprocessor speed-switching device on the
system board.
For systems with multiprocessors, confirms that the
secondary microprocessor is operational.
Checks the onboard registers of the USB interface.
This subtest does not test USB peripherals.
Monitors the ability of a USB controller to process a
simple set of memory-resident instructions.
NOTES: Not all of these tests appear for each system.
For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the Index.
Diagnostics and Troubleshooting Guide
Video
Video Memory Test
Video Hardware Test
Text Mode Character Test
Text Mode Color Test
Text Mode Pages Test
Graphics Mode Test
Color Palettes Test
Solid Colors Test
Tests the video subsystem and monitor by checking
various aspects of video output.
Keyboard
Keyboard Controller Test
Keyboard Key Sequence Test
Keyboard Interactive Test
Stuck Key Test
External Key Pad Test
Tests the keyboard by checking the keyboard
controller and by finding keys that stick or respond
incorrectly.
Mouse
Mouse
Tests the electronic pointing device (bus mouse,
serial mouse, trackball, or PS/2 mouse).
Diskette Drives
Change Line Test
Seek Test
Read Test
Write Test
Tests a drive that uses removable diskettes (3.5-inch
or 5.25-inch). Also tests the associated interface.
Hard-Disk Drives
(Non-SCSI)
Disk Controller Test
Forced Error-Correction-Code Test
Seek Test
Read Test
Write Test
Tests drives that use fixed, internal disks. Also tests
the associated interface.
IDE CD ROM
Drives
Drive Controller Test
Seek Test
Read Test
Audio Output Test
Eject Removable Media
Tests an IDE drive that uses removable CD media.
Also tests the associated interface.
Serial/Infrared
Ports
Serial/Infrared Baud Rate Test
Serial/Infrared Interrupt Test
Serial/Infrared Internal Trans-
mission Test
Serial External Transmission Test
Tests the components through which peripherals that
use the serial or infrared ports, such as printers and
communications devices, send and receive data.
Table 4-2. Dell Diagnostics Tests (continued)
Test Groups
Subtests
Description
NOTES: Not all of these tests appear for each system.
For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the Index.
Running the Dell Diagnostics
4-11
Parallel Ports
Parallel Internal Test
Parallel External Loopback Test
Parallel External Interrupt Test
Parallel Printer Pattern Test
Tests the components through which peripherals that
use the parallel port, such as printers and communi-
cations devices, send and receive data.
SCSI Devices
Internal Diagnostic
Seek Test
Read Test
Write Test
Audio Output Test
Eject Removable Media
Display Information
Tests any installed SCSI host adapters and all the
SCSI devices attached to them. Also can be used to
remove CDs and tape cartridges from SCSI devices
and to display information about the types of SCSI
devices installed and the resources allocated to them.
Network Interface
Registers Test
Internal Loopback Test
External Loopback Test
Shared RAM Test
Display Information
Tests the read and write access capability to the NIC
registers. Also tests the ability of the NIC to transmit
and receive data.
Audio
Software Reset Test
Compatibility ID Test
Interrupt Test
DMA Test
FIFO RAM Test
Initial Reset Status Test
Internal Register Test
Dual Channel Test
FM Sound Playback Test
Analog Sound Playback Test
Record and Playback Test
Tests the operation of the audio chip set.
Tests the record and playback ability
of the internal microphone and
speakers.
Table 4-2. Dell Diagnostics Tests (continued)
Test Groups
Subtests
Description
NOTES: Not all of these tests appear for each system.
For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the Index.
Diagnostics and Troubleshooting Guide
Error Messages
When you run a test group or subtest in the Dell Diagnos-
tics, error messages may result. These particular error
messages are not covered in this chapter because the
errors that generate these messages can be resolved only
with Dell technical assistance. Record the messages on a
copy of the Diagnostics Checklist found in Chapter 7,
“Getting Help.” For instructions on obtaining technical
assistance and for informing the support technician of
these messages, also see Chapter 7.
RAM Test Group
The RAM Test Group subtests check all the directly
addressable RAM.
The RAM Test program has parameters for the subtests
that you can set: Test Limits and Options.
Subtests
Three subtests are available for RAM: the Quick Mem-
ory Test, the Comprehensive Memory Test, and the
Secondary Cache Memory Test. The Quick Memory Test
performs an address check to determine whether the
computer is properly setting and clearing individual bits
in RAM and whether the RAM read and write operations
are affecting more than one memory address location at
one time. This subtest checks all available RAM. The
Comprehensive Memory Test also performs an address
check, as well as the following:
•
Data pattern checks, to look for RAM bits that are
stuck high or low, short-circuited data lines, and
some data pattern problems that are internal to the
memory chips
•
A parity check that verifies the ability of the memory
subsystem to detect errors
•
A refresh check, to verify that the dynamic RAM
(DRAM) is being recharged properly
The Secondary Cache Memory Test confirms the func-
tionality of the computer’s cache controller chip and the
cache memory.
Why Run a RAM Test?
Faulty memory can cause a variety of problems that may
not, at first glance, appear to be happening in RAM. If
your computer is displaying one or more of the following
symptoms, run the subtests in the RAM Test Group to
verify that the memory is not at fault:
•
A program is not running as usual, or a proven piece
of software appears to malfunction and you
confirm that the software itself is not at fault. (You
can confirm that the software is functioning properly
by moving it to another computer and running it
there.)
•
Your computer periodically locks up (becomes unus-
able and must be rebooted), especially at different
places and times in different programs.
•
You get parity errors (any error message that con-
tains the word parity) at any time during operation.
These errors are usually accompanied by a reference
to an address—the location of the portion of mem-
ory where the error occurred—which you should
record on a copy of the Diagnostics Checklist found
in Chapter 7, “Getting Help.”
System Set Test Group
The subtests in the System Set Test Group check the
computer’s basic system board components and verify
their related functions.
Subtests
The subtests that constitute the System Set Test Group
and the computer functions they confirm follow:
•
CMOS Confidence Test
Checks the NVRAM for accessibility and reliability
of data storage by performing a data pattern check
and verifying the uniqueness of memory addresses.
•
CMEM Confidence Test
Verifies the accessibility and reliability of the
8 kilobytes (KB) of RAM on the Extended
Industry-Standard Architecture (EISA) Configura-
tion RAM chip, which stores the EISA hardware
configuration information. On systems without flash
Running the Dell Diagnostics
4-13
RAM, performs a data pattern and address unique-
ness test.
NOTE: This test applies only to systems with an
EISA bus.
•
DMA Controller Test
Tests the direct memory access (DMA) controller
and verifies the correct operation of its page and
channel registers by writing patterns to the registers.
•
Real-Time Clock Test
Confirms the functionality and accuracy of the com-
puter’s real-time clock (RTC).
•
System Timers Test
Checks the timers used by the microprocessor for
event counting, frequency generation, and other
functions. Only the functions that can be activated
by software are tested.
•
Interrupt Controller Test
Generates an interrupt on each interrupt request
(IRQ) line to verify that devices using that line can
communicate with the microprocessor and that the
interrupt controllers send the correct memory
addresses to the microprocessor.
•
Reset Button Test
Confirms that the reset button works.
•
System Speaker Test
Checks the functionality of the speaker by generat-
ing eight tones.
•
Coprocessor Calculation Test
Checks the use of different types of numbers and the
math coprocessor’s ability to calculate correctly.
•
Coprocessor Error Exception Test
Verifies the math coprocessor’s ability to handle
errors and to send IRQs to the microprocessor.
•
PC Card Controller Test
Tests the functionality of the PC Card controller on
the system board.
•
Thermal Control Test
Checks the functionality of the thermal-monitoring
and microprocessor speed-switching device on the
system board.
•
Multiprocessor Test
For systems with multiprocessors, confirms that the
secondary microprocessor is operational.
•
USB Register Test
Checks the onboard registers of the universal serial
bus (USB) interface. This subtest does not test USB
peripherals.
•
USB Memory Structure Test
Monitors the ability of a USB controller to process a
simple set of memory-resident instructions.
Why Run a System Set Test?
The System Set subtests double-check many system
board components, such as the computer’s input/output
(I/O) circuitry, that are tested by other test groups or sub-
tests in the diagnostics. You should run the System Set
Test Group if you are having a problem and cannot iso-
late the failure or malfunction to a particular system
board component.
The System Set Test Group also verifies the proper oper-
ation of other computer components, such as the speaker,
that are not tested elsewhere in the Dell Diagnostics.
The following symptoms usually suggest a problem with
a component or subassembly that warrants running a Sys-
tem Set subtest:
•
A program is not running as usual, or a proven piece
of software appears to malfunction and you confirm
that the software itself is not at fault. (You can con-
firm that the software is functioning properly by
moving it to another computer and running it there.)
•
An option card you previously accessed can no
longer be accessed.
•
You get parity errors or page fault failures (any error
message that contains the word parity or page fault)
at any time during operation. These errors are usu-
ally accompanied by a reference to an address,
which you should record on a copy of the Diagnos-
tics Checklist found in Chapter 7, “Getting Help.”
Diagnostics and Troubleshooting Guide
•
Correcting errors in the system configuration infor-
mation in the System Setup program does not
resolve a problem.
•
The computer’s clock/calendar stops.
•
The speaker no longer functions. The problem could
be a failure of the system timers as well as a failure
of the speaker itself. Run the System Timers Test,
followed by the System Speaker Test.
•
If a peripheral device appears to malfunction, run the
Interrupt Controllers Test.
•
A spreadsheet program or other type of mathemati-
cal application runs abnormally slow, generates error
messages concerning calculations or operations, runs
incorrectly, or generates incorrect results, or a
proven piece of the program appears to malfunction
and you confirm that the software itself is not at
fault. (You can confirm that the software is not at
fault by moving the program to another computer
and running it there.)
•
The computer periodically locks up, especially at
different places and times in different programs.
•
The computer halts in the middle of performing cal-
culations or complex mathematical operations.
Video Test Group
The subtests in the Video Test Group verify the proper
operation of the video controller and the video control
circuitry installed in your computer. These subtests check
for the correct operation of the readable registers in the
video circuitry and the controller. They write, read, and
verify data patterns in the cursor registers of the control-
ler. The Video Test Group also tests all the video memory
and provides additional subtests to test the color features
of a color monitor.
Subtests
The eight subtests in the Video Test Group confirm the
following video functions:
•
Video Memory Test
Checks the read/write capability of video memory in
various video modes.
•
Video Hardware Test
Checks the cursor registers and the horizontal and
vertical retrace bit registers in the video controller.
•
Text Mode Character Test
Checks the video subsystem’s ability to present data
in text modes.
•
Text Mode Color Test
Checks the video subsystem’s ability to present color
in text modes.
•
Text Mode Pages Test
Checks the video subsystem’s ability to map and
present all available video pages on the screen, one
page at a time.
•
Graphics Mode Test
Checks the video subsystem’s ability to present data
and color in graphics modes.
•
Color Palettes Test
Checks the video subsystem’s ability to display all of
the available colors.
•
Solid Colors Test
Checks the video subsystem’s ability to show
screens full of solid colors. Allows you to check for
missing color subpixels.
Many of these tests display characters or graphics on the
screen for you to verify. Samples of these screens are
shown in Appendix A, “Diagnostic Video Tests.”
NOTE: The default limit for testing super video graphics
array (SVGA) modes is No. If you are testing an external
monitor, change the default to Yes.
Why Run a Video Test?
Many of the symptoms that would prompt you to run a
subtest in the Video Test Group are obvious, because the
monitor is the visual component of your computer sys-
tem. Before you run the Video Test Group or any of its
subtests, you should make sure that the problem is not in
your software or caused by a hardware change. You
should also try running all of the software support utili-
ties provided for the monitor and the video subsystem.
Running the Dell Diagnostics
4-15
If the following symptoms still occur, run the appropriate
test(s) as follows:
•
Ιf your monitor shows a partially formed or distorted
image, run all of the subtests in the Video Test
Group.
•
If the alignment of text or images is off, regardless of
the program you are running, run the Text Mode
Character Test, Text Mode Pages Test, and Graphics
Mode Test.
•
If you have a color monitor or a program that runs in
color, but the color is intermittent or not displayed at
all, run the Text Mode Color Test, Color Palettes
Test, and Solid Color Test.
•
If your monitor malfunctions in one mode but works
fine in another (for example, text is displayed cor-
rectly, but graphics are not), run the Text Mode
Character Test, Text Mode Color Test, Text Mode
Pages Test, and Graphics Mode Test.
Keyboard Test Group
The subtests in the Keyboard Test Group verify the cor-
rect operation of your keyboard and the keyboard
controller chip.
Subtests
The five keyboard subtests confirm the following key-
board functions:
•
Keyboard Controller Test
Confirms the ability of the keyboard controller chip
to communicate with the keyboard and the program-
ming of the controller chip
•
Keyboard Key Sequence Test
Verifies that the keys on the keyboard function cor-
rectly when you press the keys in a predefined order
•
Keyboard Interactive Test
Checks the internal microcode of the keyboard and
the external interface of the keyboard controller chip
for a malfunctioning key
•
Stuck Key Test
Checks the internal microcode of the keyboard and
the external interface of the keyboard controller chip
for a repeating key signal
•
External Key Pad Test
Checks the contact beneath the key for an electrical
impulse to ensure that the key is working properly
Why Run a Keyboard Test?
Keyboard problems are not always caused by the
keyboard. For example, a complete lockup of the com-
puter system, rendering the keyboard inoperable, is more
likely caused elsewhere. There are three symptoms that
are likely to be keyboard-related. Sometimes, the config-
uration of a program changes the function of a key or key
combination. Likewise, key configuration programs such
as ProKey can change a key’s function. Because these
programs are memory resident, you should be sure to
clear them out of your computer’s memory before run-
ning a subtest in the Keyboard Test Group. (Clear them
from memory by booting your computer from the diag-
nostics diskette.) When these possibilities have been
eliminated, and if the following symptoms occur, you
should run one or more of the subtests in the Keyboard
Test Group:
•
When you press a key, the character represented by
that key appears repeatedly; the key seems to be
stuck. Run the Stuck Key Test.
•
When you press a key and the response is different
from the usual response or the response you antici-
pated, the key contact may be damaged. Run the
Keyboard Interactive Test.
•
When a key does not work at all, run all of the sub-
tests in the Keyboard Test Group.
Mouse Test
The Mouse Test checks the functionality of the mouse
controller (which coordinates cursor movement on the
screen with corresponding movement of your mouse or
touch pad) and the operation of the mouse keys/touch
pad.
Diagnostics and Troubleshooting Guide
Subtests
There are no subtests for the Mouse Test Group.
Why Run the Mouse Test?
Mouse or touch pad problems are as likely to originate in
RAM as they are to be caused by a faulty mouse or touch
pad. Three sources of RAM-related problems include the
configuration of a program (which changes the function
of the mouse or touch pad), memory-resident programs
such as Sidekick or ProKey, and failure of a device driver
(the software that controls the function of the mouse or
touch pad). If these possibilities have been eliminated
and the following symptoms persist, run the Mouse Test:
•
When you press a mouse button or the touch pad, the
function of the button (or touch pad) continues; that
is, the button (or touch pad) seems to be stuck.
•
If the response when you press a mouse button or the
touch pad is different from the usual or anticipated
response, the button (or touch pad) contact may be
damaged.
•
A mouse button or the touch pad does not work at
all.
•
The cursor does not respond on the screen in accor-
dance with the movements you make with the mouse
or touch pad.
Diskette Drives Test Group
The subtests in the Diskette Drives Test Group allow you
to test both 5.25-inch and 3.5-inch diskette drives of all
capacities.
Subtests
The four diskette drive subtests available in the Diskette
Drives Test Group confirm the following drive functions:
•
Change Line Test
Checks for bent pins on the diskette drive controller
and for defective lines on the diskette cable
•
Seek Test
Checks the drive’s ability to search for a specified
track on the diskette and to position its read/write
heads to all tracks
•
Read Test
Positions the read/write heads at each cylinder of the
diskette for reading data and verifies that all tracks
on the diskette can be read correctly
•
Write Test
Positions the read/write heads at each cylinder of the
diskette and verifies that all tracks on the diskette
can be written to correctly
Why Run a Diskette Drives Test?
Very often, a diskette drive problem may first appear to
be a diskette problem. A box of defective diskettes might
produce faulty-drive error messages. The test results can
be confusing, so Dell suggests running the subtests in the
Diskette Drives Test Group more than once using dis-
kettes from different sources.
Another possible cause of diskette drive problems is
human error—typing a command in an incorrect form
(usually called a syntax error). Be sure you have entered
the command in the proper form.
When the diskette(s) and command syntax are eliminated
as causes, the following symptoms usually suggest a
drive problem and warrant running a subtest in the Dis-
kette Drives Test Group:
•
An error message appears on the screen stating that
the computer cannot read from or write to a diskette.
•
A diskette cannot be properly formatted, or format
error messages appear on the screen.
•
Data on diskettes is corrupted or lost; these problems
may be intermittent.
Hard-Disk Drives (Non-SCSI) Test
Group
The subtests in the Hard-Disk Drives (Non-SCSI) Test
Group check the functionality of up to four hard-disk
drives (two on each channel) of any capacity. The
Running the Dell Diagnostics
4-17
subtests check the storage capability of a drive as well as
the hard-disk drive controller (which affects the ability to
read from and write to the drive). The subtests are for all
hard-disk drive types except for small computer system
interface (SCSI) drives. To test SCSI drives, use the SCSI
Devices Test Group.
Subtests
The five subtests in the Hard-Disk Drives (Non-SCSI)
Test Group confirm the following drive functions:
•
Disk Controller Test
Checks the internal microcode of the hard-disk drive
controller
•
Forced Error-Correction-Code Test
Checks the ability of the hard-disk drive to identify
and correct errors
•
Seek Test
Checks the drive’s ability to search for a specified
track on the drive and to position the read/write
heads of the drive to all tracks
•
Read Test
Positions the read/write heads at each cylinder of the
drive for reading data and verifies that all tracks on
the drive can be read correctly
•
Write Test
Positions the read/write heads at each cylinder of the
drive and verifies that all tracks on the drive can be
written to correctly
Why Run a Hard-Disk Drives Test?
If you check your hard-disk drive to determine the
amount of available space, your operating system will
probably report problem areas. Problem areas on hard-
disk drives are common, because most hard-disk drives
have a small amount of space that is not usable. The hard-
disk drive keeps a record of this space so that your
computer will not attempt to use it. Identification of
unusable disk space, unless it is an unusually large
amount (over five percent of the possible total), should
not be regarded as a cause for testing the hard-disk drive.
These are the most common symptoms that might prompt
you to test the hard-disk drive:
•
The hard-disk drive fails during the boot routine.
•
Seek errors are reported by the operating system or
application programs.
•
An error message appears on the screen stating that
the computer cannot read from or write to the hard-
disk drive.
•
Data on the hard-disk drive is corrupted or lost; these
problems may be intermittent. Once saved by a pro-
gram, files cannot be properly recalled.
IDE CD ROM Drives Test Group
The subtests in the IDE CD ROM Drives Test Group
check the functionality of up to four IDE CD-ROM
drives connected to the primary and secondary IDE ports.
Before conducting an IDE CD-ROM test, insert a CD
with audio and data tracks (such as a multimedia CD)
into each CD-ROM drive.
NOTES: All of the subtests except for the Audio Output
Test require a CD with data tracks. The Audio Output
Test requires a CD with audio tracks.
If a CD-ROM drive is empty, or if it contains a CD that
does not have the required data or audio tracks (depend-
ing on the subtest[s] being conducted), the subtest(s) will
fail.
Subtests
The five subtests in the IDE CD ROM Drives Test Group
confirm the following drive functions:
•
Drive Controller Test
Causes the drive to execute its internal self-test.
•
Seek Test
Checks the drive’s ability to search for each block on
the device.
•
Read Test
Positions the read heads at each block of the device
for reading data and verifies that all blocks on the
device can be read correctly.
Diagnostics and Troubleshooting Guide
•
Audio Output Test
Causes the drive to begin playing the first audio
track on an audio CD. To determine whether the test
passed, listen to the audio output of the drive.
NOTE: To conduct the Audio Output Test, you must
select it individually. It will not run as part of the test
group.
•
Eject Removable Media
Checks the drive’s ability to eject its CD.
Why Run an IDE CD ROM Drives Test?
If you encounter a problem while using an application
program on a CD, the problem could result from the disc
or from the drive. When you encounter problems, first try
using a different CD. If the problem recurs, run the IDE
CD ROM Drives Test Group.
These are the most common symptoms that might prompt
you to test an IDE CD-ROM drive:
•
Seek errors are reported by the operating system or
application programs.
•
An error message appears on the screen stating that
the computer cannot read from an IDE CD-ROM
drive (typically, drive D or drive E).
Serial/Infrared Ports Test Group
The subtests in the Serial/Infrared Ports Test Group
check the computer’s interface with external devices,
such as a printer and a mouse, that are connected to the
computer through a serial or infrared port. The subtests in
this test group are not intended as a diagnostic test for the
actual peripheral attached to each port.
NOTES: With certain modems installed, the Serial/
Infrared Ports Test Group subtests may fail because the
modem appears to the Dell Diagnostics as a serial or
infrared port, but it cannot be tested as a serial or infra-
red port. If a modem is installed and one of the serial/
infrared ports subtests fails, remove the modem and run the
diagnostic tests again.
If an external loopback connector is not attached to a
serial or infrared port, the Serial External Transmission
Test will fail for that port and the results of this test
should therefore be ignored. An external modem con-
nected to the port does not substitute for an external
loopback connector.
Subtests
The four subtests in the Serial/Infrared Ports Test Group
confirm the following port functions:
•
Serial/Infrared Baud Rate Test
Checks the baud rate generator in each serial com-
munications chip against the computer’s clock
•
Serial/Infrared Interrupt Test
Checks the serial port’s ability to send IRQs to the
microprocessor
•
Serial/Infrared Internal Transmission Test
Checks several internal functions of the serial port
using the internal loopback mode of the serial com-
munications chip
•
Serial External Transmission Test
If a loopback device is attached, checks the line con-
trol bits of the serial port and sends a test pattern at
several baud rates, checking the returned values
Why Run a Serial/Infrared Ports Test?
If the Dell Diagnostics does not recognize your com-
puter’s serial or infrared ports, enter the System Setup
program and check the Serial/infrared Port category to
see whether the port has been disabled. The subtests in
the Serial/Infrared Ports Test Group cannot test a port
unless it is enabled.
When a port is faulty, it may not be immediately evident
that the port, and not the device connected to the port, is
faulty. Instead, the peripheral (such as a printer or mouse)
might behave erratically or not operate at all. If the
external device is not properly installed through your
software, it also may not function properly. Try operating
the peripheral from different programs or through the
operating system. If it still does not work, you can
eliminate the software configuration as the cause of the
problem.
Running the Dell Diagnostics
4-19
Another possible cause for errors is the external device.
Use the documentation that came with the peripheral to
troubleshoot it and confirm that it is working properly.
(Most printers have a self-test.)
After you eliminate incorrect system configuration
information settings, peripheral malfunctions, and soft-
ware errors as potential causes of port problems, you can
run the subtests in the Serial/Infrared Ports Test Group to
check your hardware. Although the following symptoms
can be caused by faulty peripherals or software errors,
they might also suggest a port problem:
•
If a peripheral works intermittently or produces
intermittent errors, the port may be faulty.
•
If the computer displays an error message that is
related to the external device connected to a port, but
corrections to the device do not resolve the error, run
the appropriate subtest in the Serial/Infrared Ports
Test Group.
•
If your software and the diagnostics do not recognize
that you have a serial or infrared port, you should
check the Serial/Infrared Port category in the System
Setup program, and if necessary, run the appropriate
subtest in the Serial/Infrared Ports Test Group.
Parallel Ports Test Group
The subtests in the Parallel Ports Test Group check the
computer’s interface with external devices, such as a
printer, that are connected to the computer through a par-
allel port. The subtests in this test group are not intended
as a diagnostic test for the actual peripheral attached to
each port. (The only exception is a printer, as described in
the Parallel Internal Test.)
NOTE: If an external loopback connector is not attached
to the parallel port, the Parallel External Loopback Test
will fail for that port and the results of this test should
therefore be ignored.
Subtests
The four subtests in the Parallel Ports Test Group confirm
the following port functions:
•
Parallel Internal Test
Checks several internal functions of the parallel port
•
Parallel External Loopback Test
Tests the functionality of the control lines through an
external loopback connector, if an external loopback
connector is available
•
Parallel External Interrupt Test
Tests the parallel port’s ability to generate interrupts
from all possible sources, if an external loopback
connector or printer is available
•
Parallel Printer Pattern Test
Tests a printer and tests the parallel port’s ability to
send a pattern to the printer, if connected
Why Run a Parallel Ports Test?
If the Dell Diagnostics does not recognize your com-
puter’s parallel port, enter the System Setup program and
check the Parallel Port category to see if the port has been
disabled. The subtests in the Parallel Ports Test Group
cannot test a port unless it is enabled.
When a port is faulty, it may not be immediately evident
that the port, and not the device connected to the port, is
faulty. Instead, the peripheral (such as a printer) might
behave erratically or not operate at all. If the external
device is not properly installed through your software, it
also may not function properly. Try operating the periph-
eral from different programs or through the operating
system. If it still does not work, you can eliminate the
software setup as the cause of the problem.
Another possible cause for errors is the external device.
Use the documentation that came with the peripheral to
troubleshoot it and confirm that it is working properly.
(Most printers have a self-test.)
After you eliminate incorrect system configuration infor-
mation settings, peripheral malfunctions, and software
errors as potential causes of port problems, you can run
the subtests in the Parallel Ports Test Group to check your
hardware. Although the following symptoms can be
caused by faulty peripherals or software errors, they
might also suggest a port problem:
•
If a peripheral works intermittently or produces
intermittent errors, the port may be faulty.
•
If the computer displays an error message that is
related to the external device connected to a port, but
corrections to the device do not resolve the error, run
Diagnostics and Troubleshooting Guide
the appropriate subtest in the Parallel Ports Test
Group.
•
If your software and the Dell Diagnostics do not rec-
ognize that you have a parallel port, you should
check the Parallel Port category in the System Setup
program, and if necessary, run the appropriate sub-
test in the Parallel Ports Test Group.
SCSI Devices Test Group
The subtests in the SCSI Devices Test Group check the
functionality of up to four SCSI host adapters and all the
SCSI devices attached to them.
NOTES: Before conducting these subtests on CD-ROM
drives, insert a CD with audio and data tracks (such as a
multimedia CD) into each CD-ROM drive. All of the sub-
tests, except for the Audio Output Test, require a CD with
data tracks. The Audio Output Test requires a CD with
audio tracks.
If a CD-ROM drive is empty or if it contains a CD that
does not have the required data or audio tracks (depend-
ing on the subtest[s] being conducted), the subtest(s) will
fail.
Subtests
The seven subtests in the SCSI Devices Test Group con-
firm the following drive functions:
•
Internal Diagnostic
Causes the device to run its internal self-test.
•
Seek Test
Checks the device’s ability to search for a specified
track on the device and to position its read/write
heads to all tracks.
•
Read Test
Positions the read/write heads at each block of the
device for reading data and verifies that all tracks on
the device can be read correctly.
•
Write Test
Positions the read/write heads at each block of the
device and verifies that all tracks on the device can
be written to correctly.
•
Audio Output Test
Causes the CD-ROM drive to begin playing the first
audio track on an audio CD. To determine whether
the test passed, listen to the audio output of the drive.
NOTE: To conduct the Audio Output Test, you must
select it individually. It will not run as part of the test
group.
•
Eject Removable Media
Causes a CD-ROM drive to eject its CD or a SCSI
tape drive to eject its tape cartridge.
•
Display Information
Displays a screen of information about each SCSI
host adapter in the computer, the resources allocated
to each SCSI host adapter, and a list of target devices
attached to the SCSI host adapter.
Why Run a SCSI Devices Test?
If you check your SCSI hard-disk drive to determine the
amount of available space, your operating system will
probably report problem areas. Problem areas on hard-
disk drives are common, because most hard-disk drives
have a small amount of space that is not usable. The hard-
disk drive keeps a record of this space so that your
computer will not attempt to use it. Identification of
unusable disk space, unless it is an unusually large
amount (over five percent of the possible total), should
not be regarded as a cause for testing the hard-disk drive.
These are the most common symptoms that might prompt
you to test a SCSI device:
•
A SCSI hard-disk drive fails during the boot routine.
•
Seek errors are reported by the operating system or
application programs.
•
An error message appears on the screen stating that
the computer cannot read from or write to a SCSI
device.
•
Data on a SCSI device is corrupted or lost; this prob-
lem may be intermittent. Once saved by a program,
files cannot be properly recalled.
Running the Dell Diagnostics
4-21
Network Interface Test Group
The subtests in the Network Interface Test Group verify
the basic operation of the network interface controller
(NIC). They test its internal functions, including read and
write access to its registers and internal transmit and
receive (loopback) capability.
Subtests
The subtests in the Network Interface Test Group con-
firm the following functions:
•
Registers Test
Writes patterns to the writable registers in the con-
troller and reads the patterns back to verify whether
they are accessible and able to retain data. This
subtest also tests interrupt generation and register-
specific functionality based on the type of controller.
•
Internal Loopback Test
Places the controller into its various internal loop-
back modes and tests its ability to transmit and
receive data.
NOTE: For some controllers, this test is not
applicable.
•
External Loopback Test
Places the controller into its various external loop-
back modes and tests its ability to transmit and
receive data. A loopback plug is required to perform
this test.
NOTE: For some controllers, this test is not
applicable.
•
Shared RAM Test
Performs a memory test on controllers with memory-
mapped shared RAM. On controllers with first-in
first-out (FIFO)-shared RAM, writes a data pattern
to all locations and reads the pattern back to verify
the operation. Some controllers do not support
shared RAM tests.
•
Display Information
Displays addresses and configuration information
about the NIC. This information includes the net-
work address used for communication on the local
area network (LAN).
Why Run a Network Interface Test?
Running a subtest in the Network Interface Test Group
helps diagnose problems that may be encountered while
the system is operating in a network environment. Most
network failures are caused by one of the following:
•
Poor network connections
•
Failure in the controller
•
Interrupt conflict (the controller trying to use the
same IRQ line as another device)
•
Software configuration error
If a problem occurs while the system is operating in a
network, the network connection should be inspected. If
the connection is good, the Network Interface Test Group
can be run to indicate whether the NIC is functioning,
and if the test group is run in a loop, it can be used to
detect intermittent failures.
The Registers Test subtest checks the interrupt generation
capability of the controller. The Display Information Test
displays the controller’s IRQ level. You can then make
sure there is not an interrupt conflict by verifying that the
IRQ level is not being used by another device in the
system.
Audio Test Group
The subtests in the Audio Test Group check the functions
of the audio controller and the computer’s recording and
playback features.
NOTE: The following subtests are only applicable for
systems with built-in speakers.
Subtests
The eleven subtests in the Audio Test Group confirm the
following functions:
•
Software Reset Test
Checks for the presence of an active audio controller
in your system
•
Compatibility ID Test
Determines if the correct sound controller is installed
in your system
Diagnostics and Troubleshooting Guide
•
Interrupt Test
Checks to see if the audio controller is generating an
interrupt on the IRQ line configured for that
controller
•
DMA Test
Tests for the presence of a DMA channel on the sys-
tem chip set, and determines if the DMA controller
and audio controller can exchange signals
•
FIFO RAM Test
Checks the read/write capabilities and status of the
audio controller
•
Initial Reset Status Test
Verifies the reset values of the extended registers on
the audio controller
•
Internal Register Test
Writes test patterns to the internal registers of the
audio controller, then reads other registers to confirm
that the patterns are correctly interpreted
•
Dual Channel Test
Confirms the presence of a second DMA channel on
the system chip set and determines if the DMA con-
troller and audio controller can exchange signals on
that second DMA channel
•
FM Sound Playback Test
Tests whether the system can synthesize sounds and
play them through the built-in speakers
•
Analog Sound Playback Test
Tests whether the system can play sampled sounds
through the built-in speakers
•
Record and Playback Test
Checks the ability of the audio controller to generate
a sampled sound from signals received from the
built-in microphone
Why Run an Audio Test?
If you do not hear sounds from your built-in speakers when
you expect to, it is possible that your operating system or
sound application uses resource settings different from
those of the audio controller in the computer. In the absence
of an expected sound, first check the documentation that
accompanied your operating system or sound application to
see if the sound features are correctly configured to work
with the computer. The default settings for the audio con-
troller are:
•
DMA channel: 1
•
IRQ line: 5
•
Port address: 220h
If necessary, change the resource settings in your operat-
ing system or sound application to match these default
settings.
If you still do not hear sound when you expect to, run the
Audio Test Group.
NOTE: Before running the Audio Test group, make sure
to enable the built-in speaker(s), and make sure that the
speaker volume has not been muted.
Other Test Group
The subtests in the Other Test Group check devices that
are currently not covered by one of the other groups.
Subtests
The three subtests in the Other Test Group confirm the
following functions:
•
ESM Firmware Status
Checks to make sure the embedded server manage-
ment (ESM) firmware was downloaded correctly
and is operational
•
ESM Interface Test
Checks the interface between the host and the ESM
hardware to ensure all bits in the data port are work-
ing properly
•
ESM Sensor Check
Verifies the current measurements of the ESM
sensors
Checking Your Equipment
5-1
Chapter 5
Checking Your Equipment
This chapter provides troubleshooting procedures for
equipment that connects directly to the input/output (I/O)
panel of your computer, such as your monitor, keyboard,
mouse, or printer. Before performing any of the proce-
dures in this chapter, see “Checking Connections and
Switches” in Chapter 1. Then perform the troubleshoot-
ing procedures for the equipment that is malfunctioning.
You need the following items to perform the procedures
in this chapter:
•
A copy of the Dell Diagnostics Diskette
•
Your system documentation
NOTE: When you see the question, “Is the problem
resolved?” in a troubleshooting procedure, perform the
operation that caused the problem.
Troubleshooting the Monitor
Troubleshooting video problems involves determining
which of the following is the source of the problem:
•
Monitor and monitor interface cable
•
Video memory
•
Video logic of the computer or the high-resolution
video expansion card, which overrides the video
logic of the computer
The procedures in this section troubleshoot problems
with the monitor and the monitor interface cable only.
See Chapter 6, “Checking Inside Your Computer,” for
troubleshooting procedures for video expansion cards,
video memory, and your computer’s video logic.
If information on the monitor screen is displayed incor-
rectly or not at all, complete the following steps to
determine the problem:
1.
Turn on the system, including any attached
peripherals.
2.
Adjust the switches and controls as specified in
the monitor’s documentation to correct the video
image, including the horizontal and vertical posi-
tion and size.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 3.
3.
Insert the Dell Diagnostics Diskette into drive A,
and reboot the system.
Does the monitor display text properly?
Yes. Go to step 5.
No. Go to step 4.
4.
Type g and press the down-arrow key four times.
Then press the plus (+) key to send all error mes-
sages to a printer, or press the plus (+) key twice
to send the error messages to a file named result
on a diskette that you insert into drive A when
prompted. If you are running the diagnostics
from a utility partition on your hard-disk drive,
the result file will be saved on the hard-disk drive.
5.
Run the Video Test Group in the Dell Diagnostics.
(See Chapter 4, “Running the Dell Diagnostics.”)
Most of the tests in the Video Test Group require you
to respond before the diagnostics continues with the
next test.
Diagnostics and Troubleshooting Guide
Do the tests complete successfully?
Yes. You have fixed the problem.
No. Go to step 6.
6.
Turn off the system and disconnect it from alter-
nating current (AC) power. Swap the monitor
with one of the same type that is working, and
reconnect the system to AC power.
7.
Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the Video Test Group
again.
Do the tests complete successfully?
Yes. You probably need a new monitor. See
Chapter 7, “Getting Help,” for instructions on
obtaining technical assistance.
No. If you have a video expansion card installed in
your computer, see “Troubleshooting Expansion
Cards” in Chapter 6.
Troubleshooting the Keyboard
This procedure determines what kind of keyboard prob-
lem you have. If a system error message indicates a
keyboard problem when you start up the computer sys-
tem or during the Dell Diagnostics, complete the
following steps:
1.
Look at the keyboard and the keyboard cable for
any signs of damage. Press and release each key
on the keyboard.
Do the keyboard and its cable appear to be free of
physical damage, and do the keys work?
Yes. Go to step 3.
No. Go to step 2.
2.
Swap the faulty keyboard with a working
keyboard.
To swap a faulty keyboard, unplug the keyboard
cable from your computer’s back panel and plug in a
working keyboard.
Is the problem resolved?
Yes. You probably need a new keyboard. See Chap-
ter 7, “Getting Help,” for instructions on obtaining
technical assistance.
No. Go to step 3.
3.
Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the Keyboard Test
Group in the Dell Diagnostics. (See Chapter 4,
“Running the Dell Diagnostics.”)
Can you use the keyboard to select the Keyboard
Test Group?
Yes. Go to step 4.
No. Go to step 5.
4.
Does the Keyboard Interactive Test complete
successfully?
Yes. Go to step 6.
No. Go to step 5.
5.
Swap the faulty keyboard with a working
keyboard.
6.
Does the Keyboard Controller Test complete
successfully?
Yes. You need a new keyboard. See Chapter 7, “Get-
ting Help,” for instructions on obtaining technical
assistance.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting I/O Ports
This section provides a procedure for troubleshooting the
ports on your computer’s I/O panel and the equipment
connected to them, such as a printer, scanner, or other
peripheral device.
You can also use this procedure to test I/O ports on
expansion cards. However, you should first complete the
procedures in “Troubleshooting Expansion Cards” in
Chapter 6 to verify that the card is configured and
installed correctly.
If a system error message indicates a port problem or
if equipment connected to a port seems to perform
Checking Your Equipment
5-3
incorrectly or not at all, the source of the problem may be
any of the following:
•
A faulty connection between the I/O port and the
peripheral device
•
A faulty cable between the I/O port and the periph-
eral device
•
A faulty peripheral device
•
Incorrect settings in the System Setup program
•
Incorrect settings in the system’s configuration files
•
Faulty I/O port logic on the system board
NOTE: With certain modems installed, the Serial Port
Test Group subtests may fail because the modem appears
to the diagnostics as a serial port, but it cannot be tested
as a serial port. If you have a modem installed and you
experience a serial-port test failure, remove the modem
and run the diagnostic tests again.
Troubleshooting the Basic I/O
Functions
This procedure determines whether the computer’s basic
I/O functions are operational. If a system error message
indicates an I/O port problem or the device connected to
the port does not function properly, follow these steps:
1.
Enter the System Setup program and check the
settings for the Serial Port 1, Serial Port 2, Paral-
lel Port, and Mouse categories.
NOTE: Not all systems have a Mouse category in the
System Setup program.
Are the communication port categories set to Auto,
and is the Mouse category set to On?
Yes. Go to step 3.
No. Go to step 2.
2.
Change the setting for the Serial Port 1, Serial
Port 2, and Parallel Port categories to Auto, and
change the setting for the Mouse category to On;
then reboot the system.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 3.
3.
Check the contents of your start-up files (such as
autoexec.bat and config.sys). (See “Installing and
Configuring Software” in Chapter 3.)
Are the port configuration commands correct?
Yes. Go to step 5.
No. Go to step 4.
4.
Change the necessary statements in the start-up
files.
If the port problem is confined to a particular appli-
cation program, see the application program’s
documentation for specific port configuration
requirements.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 5.
5.
Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the Serial/ Infrared
Ports Test Group and/or the Parallel Ports Test
Group in the Dell Diagnostics. (See Chapter 4,
“Running the Dell Diagnostics.”)
The Serial/Infrared Ports Test Group and the Parallel
Ports Test Group test the basic functions of the sys-
tem board’s I/O port logic. Also, if a parallel printer
is connected to the parallel port, the Parallel Ports
Test Group tests the communication link between the
system board’s I/O port logic and the printer.
Do the tests complete successfully?
Yes. Go to step 6.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
6.
If the problem persists, go to “Troubleshooting a
Parallel Printer” or “Troubleshooting a Serial
I/O Device” found later in this chapter, depending
on which device appears to be malfunctioning.
Diagnostics and Troubleshooting Guide
Troubleshooting a Parallel Printer
If the preceding procedure, “Troubleshooting the Basic
I/O Functions,” indicates that the problem is with a paral-
lel printer, follow these steps:
1.
Turn off the parallel printer and computer.
2.
Swap the parallel printer interface cable with a
known working cable.
3.
Turn on the parallel printer and computer.
4.
Attempt a print operation on the parallel printer.
Does the print operation complete successfully?
Yes. You probably need a new interface cable. See
Chapter 7, “Getting Help,” for instructions on
obtaining technical assistance.
No. Go to step 5.
5.
Run the parallel printer’s self-test.
Does the self-test complete successfully?
Yes. Go to step 6.
No. The printer is probably defective. If you bought
the printer from Dell, see Chapter 7, “Getting Help,”
for instructions on obtaining technical assistance. If
you bought the printer elsewhere, take it to one of
the manufacturer’s authorized service centers for
repair.
6.
Attempt another print operation on the parallel
printer.
Does the print operation complete successfully?
Yes. You have fixed the problem.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting a Serial I/O Device
If the procedure titled “Troubleshooting the Basic I/O
Functions” indicates that the problem is with a device
connected to one of the serial ports, follow these steps:
1.
Turn off the computer and any peripheral devices
connected to the serial ports.
Are two serial devices connected to the computer?
Yes. Go to step 2.
No. Go to step 4.
2.
Disconnect the devices from serial ports 1 and 2,
and connect the malfunctioning serial device to
the opposite port.
3.
Turn on the computer and the reconnected serial
device.
Is the problem resolved?
Yes. The serial port may be defective. See Chapter 7,
“Getting Help,” for instructions on obtaining techni-
cal assistance.
No. Go to step 4.
4.
Turn off the computer and the serial device, and
swap the interface cable (that connects the device
to the serial port) with a known working cable.
5.
Turn on the computer and the serial device.
Is the problem resolved?
Yes. You probably need a new interface cable. See
Chapter 7, “Getting Help,” for instructions on
obtaining technical assistance.
No. Go to step 6.
6.
Turn off the computer and the serial device, and
swap the device with a comparable working
device.
For example, if your serial mouse has a problem,
swap it with a serial mouse you know is working
properly.
7.
Turn on the computer and the serial device.
Is the problem resolved?
Yes. You probably need a new device. See
Chapter 7, “Getting Help,” for instructions on
obtaining technical assistance.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Checking Inside Your Computer
6-1
Chapter 6
Checking Inside Your Computer
This chapter provides troubleshooting procedures for
components inside your computer. Before you start any
of the procedures in this chapter, do the following:
•
Perform the procedures described in “Checking Con-
nections and Switches” and “The System Setup
Program” in Chapter 1.
•
Read the safety instructions in “Safety First—For
You and Your Computer” found next in this chapter.
You need the following items to perform the procedures
in this chapter:
•
A copy of the Dell Diagnostics Diskette
•
Your system documentation
•
A small flat-blade screwdriver and a #1 Phillips-
head screwdriver (or quarter-inch hex-nut driver)
NOTE: When you see the question, “Is the problem
resolved?” in a troubleshooting procedure, perform the
operation that caused the problem.
Safety First—For You and Your
Computer
The procedures in this chapter require that you remove
the cover and work inside your computer. While working
inside your computer, do not attempt to service the com-
puter except as explained in this guide and elsewhere in
Dell documentation. Always follow the instructions
closely.
Working inside your computer is safe—if you observe the
following precautions.
In addition, Dell recommends that you periodically
review the safety instructions at the front of this guide.
Removing and Replacing the
Computer Cover
To troubleshoot problems inside your computer, you need
to remove the computer cover. Instructions for removing
the computer cover are in your system documentation.
WARNING FOR YOUR PERSONAL SAFETY
AND PROTECTION OF YOUR EQUIPMENT
Before starting to work on your computer, perform
the following steps in the sequence indicated:
1.
Turn off your computer and all peripherals.
2.
Disconnect your computer and peripherals
from their power sources. Doing so reduces the
potential for personal injury or shock. Also dis-
connect any telephone or telecommunication
lines from the computer.
3.
Touch an unpainted metal surface on the com-
puter chassis, such as the metal around the
card-slot openings at the back of your com-
puter, before touching anything inside your
computer.
While you work, periodically touch an
unpainted metal surface on the computer chas-
sis to dissipate any static electricity that might
harm internal components.
Diagnostics and Troubleshooting Guide
When you finish your troubleshooting procedure, replace
the cover of your computer by following the steps out-
lined in your system documentation.
Troubleshooting a Wet Computer
Liquids can damage your computer. While you are not
likely to submerge your computer, spills, splashes, and
excessive humidity can also cause damage. If an external
device (such as a printer or an external drive) gets wet,
contact the manufacturer for instructions. If your com-
puter gets wet, complete the following steps:
1.
Turn off the system, including any attached
peripherals, and disconnect all the alternating
current (AC) power cables from their power
sources. Also, disconnect any telephone or tele-
communication lines from the computer.
2.
Remove the computer cover.
3.
Let the computer dry for at least 24 hours.
Make sure that it is thoroughly dry before
proceeding.
4.
Remove all expansion cards installed in the com-
puter except a drive controller card and video
expansion card (if applicable).
See your system documentation for instructions.
5.
Replace the computer cover, reconnect the system
to AC power, and turn it on.
Does the system have power?
Yes. Go to step 6.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
6.
Turn off the system, disconnect it from AC power,
remove the computer cover, and reinstall all
expansion cards you removed in step 4.
See your system documentation for instructions.
7.
Replace the computer cover, and reconnect the
system to AC power. Also, reconnect any tele-
phone or telecommunication lines to the
computer.
8.
Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the System Set Test
Group in the Dell Diagnostics. (See Chapter 4,
“Running the Dell Diagnostics.”)
Do the tests complete successfully?
Yes. Your system is operating properly.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting a Damaged
Computer
If your computer was dropped or damaged, you should
check your computer to see if it functions properly. If an
external device attached to your computer is dropped or
damaged, contact the manufacturer of the device for
instructions or see Chapter 7, “Getting Help,” for infor-
mation on obtaining technical assistance from Dell.
Follow these steps to troubleshoot a damaged computer:
1.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
2.
Remove the computer cover.
3.
Check all the expansion-card connections in the
computer.
See your system documentation for instructions.
4.
Verify the diskette/tape drive, hard-disk drive,
and all other internal connections (including
options such as video-memory upgrade modules,
math coprocessors, and microprocessor
upgrades).
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-3
Make sure that all cables are properly connected and
that all components are properly seated in their con-
nectors and sockets.
See your system documentation for instructions.
5.
Replace the computer cover, reconnect the system
to AC power, and reconnect any telephone or tele-
communication lines.
6.
Insert the Dell Diagnostics Diskette into drive A,
and reboot the system.
7.
Run the System Set Test Group in the Dell Diag-
nostics. (See Chapter 4, “Running the Dell
Diagnostics.”)
Do the tests complete successfully?
Yes. Your system is operating properly.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting the Battery
If an error message indicates a problem with the battery
or if the System Setup program loses the system configu-
ration information when the computer is turned off, the
battery may be defective.
Follow these steps to troubleshoot the battery:
1.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
2.
Remove the computer cover.
3.
Check the connection of the battery to the system
board.
Some systems have a coin cell battery that snaps into
a socket on the system board. Other systems have a
battery with a cable that attaches to a header connec-
tor on the system board.
Is the battery firmly attached to the battery socket or
connector on the system board?
Yes. Go to step 5.
No. Go to step 4.
4.
Reseat the battery in its socket, or reconnect the
battery cable to the system board.
Is the problem resolved?
Yes. The connection was loose. You have fixed the
problem.
No. Go to step 5.
5.
Replace the battery.
See your system documentation for instructions.
Is the problem resolved?
Yes. The battery’s charge was low. You have fixed
the problem.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
WARNING
There is a danger of a new battery exploding if it is
incorrectly installed. Replace the battery only with
the same or equivalent type recommended by the
manufacturer. Discard used batteries according to
the manufacturer’s instructions.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Diagnostics and Troubleshooting Guide
Troubleshooting Expansion
Cards
If an error message indicates an expansion-card problem
or if an expansion card seems to perform incorrectly or
not at all, the problem could be a faulty connection, a
conflict with software or other hardware, or a faulty
expansion card. Follow these steps to troubleshoot
expansion cards:
1.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
2.
Remove the computer cover.
3.
Verify that each expansion card is firmly seated
in its connector.
Are the expansion cards properly seated in their
connectors?
Yes. Go to step 5.
No. Go to step 4.
4.
Reseat the expansion cards in their connectors.
See your system documentation for instructions.
Is the problem resolved?
Yes. The connection was loose. You have fixed the
problem.
No. Go to step 5.
5.
Verify that the appropriate cables are firmly con-
nected to their corresponding connectors on the
expansion cards.
For instructions on which cables should be attached
to specific connectors on an expansion card, see the
expansion card’s documentation.
Are the appropriate cables firmly attached to their
connectors?
Yes. Go to step 7.
No. Go to step 6.
6.
Reconnect the cable connectors to the appropri-
ate connectors on the expansion cards.
Is the problem resolved?
Yes. The cable connections were loose. You have
fixed the problem.
No. Go to step 7.
7.
Inspect all jumpers and configuration switches on
each expansion card.
Most Industry-Standard Architecture (ISA)
expansion cards have configuration settings for an
interrupt request (IRQ) line, a direct memory access
(DMA) channel, and a base-memory or basic input/
output system (BIOS) address. To keep expansion
cards from conflicting with each other, you need to
know both the starting memory address and the
amount of memory required by each card. For
instructions on jumpers and configuration settings,
see the expansion card’s documentation.
Is each expansion card configured correctly?
Yes. Go to step 9.
No. Go to step 8.
8.
Reconfigure the card according to the instruc-
tions in the card’s documentation.
Is the problem resolved?
Yes. The memory configuration of the card was
incorrect. You have fixed the problem.
No. Go to step 9.
9.
Inspect all configuration jumpers on the system
board to ensure that they are configured correctly
for any installed expansion cards.
For information on the configuration jumpers and
their settings, see your system documentation.
Are the system board’s configuration jumpers set
correctly?
Yes. Go to step 11.
No. Go to step 10.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-5
10. Correct the system board’s configuration jumper
settings.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 11.
11. Remove all expansion cards except the hard-disk
drive controller card (if one is installed).
See your system documentation for instructions.
12. Replace the computer cover, reconnect the system
to AC power, and turn it on.
13. Enter the System Setup program, and update the
system configuration information.
14. Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the RAM Test Group
in the Dell Diagnostics. (See Chapter 4, “Running
the Dell Diagnostics.”)
Do the tests complete successfully?
Yes. Go to step 15.
No. See Chapter 7, “Getting Help,” for information
on obtaining technical assistance.
15. Turn off the system, disconnect it from AC power,
and remove the computer cover.
16. Reinstall one of the expansion cards you removed
in step 11, and repeat steps 12 and 13.
17. Insert the Dell Diagnostics Diskette into drive A,
and reboot the system. Run the RAM Test Group
in the Dell Diagnostics.
Do the tests complete successfully?
Yes. Go to step 18.
No. See Chapter 7, “Getting Help,” for information
on obtaining technical assistance.
18. Remove the Dell Diagnostics Diskette from
drive A. Repeat steps 15, 16, and 17 for each of
the remaining expansion cards that you removed
in step 11.
Have you reinstalled all of the expansion cards with-
out encountering a test failure?
Yes. You have fixed the problem.
No. See Chapter 7, “Getting Help,” for information
on obtaining technical assistance.
Troubleshooting System Memory
A computer memory problem can be a faulty single in-
line memory module (SIMM), an improperly configured
or faulty memory expansion card (if one is installed), or a
faulty system board. If a random-access memory (RAM)
error message appears, the computer probably has a
memory problem.
When you turn on or reboot the system, the Caps Lock
and Scroll Lock indicators on the keyboard should flash
momentarily and then turn off. If the Num Lock category
in the System Setup program is set to On, the Num Lock
indicator should flash momentarily and then remain on;
otherwise, it should turn off. Abnormal operation of these
indicators can result from a defective SIMM in socket A.
Follow these steps to troubleshoot system memory:
1.
Turn on the system, including any attached
peripherals.
Does an error message appear indicating invalid sys-
tem configuration information after the memory
count completes?
Yes. Go to step 2.
No. Go to step 8.
2.
Enter the System Setup program to check the
Total Memory or System Memory category.
Does the amount of memory installed match the
Total Memory or System Memory setting?
Yes. Go to step 8.
No. Go to step 3.
Diagnostics and Troubleshooting Guide
3.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
4.
Remove the computer cover.
5.
Reseat the SIMMs in their sockets.
See your system documentation for instructions.
6.
Replace the computer cover, reconnect the system
to AC power, and turn it on.
7.
Enter the System Setup program to check the
Total Memory or System Memory category again.
Does the amount of memory installed match the
Total Memory or System Memory setting?
Yes. Go to step 8.
No. Go to step 9.
8.
Reboot the system, and observe the monitor
screen and the Num Lock, Caps Lock, and Scroll
Lock indicators on the keyboard.
Does the monitor screen remain blank, and do the
Num Lock, Caps Lock, and Scroll Lock indicators
on the keyboard remain on?
Yes. Go to step 9.
No. Go to step 11.
9.
Turn off the system, disconnect it from AC power,
and remove the computer cover.
10. If possible, swap the SIMM in socket A with one
of the same capacity, reboot the system, and
observe the monitor screen and the indicators on
the keyboard.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 11.
11. Determine whether there is a memory expansion
card installed in an expansion slot.
Is a memory expansion card installed?
Yes. Go to step 12.
No. Go to step 14.
12. Check the memory expansion card’s documenta-
tion to determine whether the card is configured
correctly.
Is the memory expansion card configured correctly?
Yes. Go to step 13.
No. Go to step 14.
13. Reconfigure the memory expansion card.
14. Replace the computer cover, reconnect the system
to AC power, reconnect any telephone or telecom-
munication lines and turn it on.
15. Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the RAM Test Group
in the Dell Diagnostics. (See Chapter 4, “Running
the Dell Diagnostics.”)
Do the tests complete successfully?
Yes. You have fixed the problem.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting the Video
Subsystem
Troubleshooting video problems involves determining
which of the following is the source of the problem: the
monitor, the monitor interface cable, the video memory,
or the video logic of the computer. You can also have a
high-resolution video expansion card installed, which
overrides the video logic of the computer.
The following procedure troubleshoots problems with the
video memory and video logic only. Before you begin,
perform the procedure found in “Troubleshooting the
Monitor” in Chapter 5 to determine whether or not the
monitor is the source of the problem.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-7
If you have a high-resolution video expansion card, first
complete the steps in “Troubleshooting Expansion
Cards” found earlier in this chapter to verify that the card
is configured and installed correctly.
Follow these steps to troubleshoot the video subsystem:
1.
Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the Video Test Group
in the Dell Diagnostics. (See Chapter 4, “Running
the Dell Diagnostics.”)
Most of the tests in the Video Test Group are interac-
tive; that is, you must respond before the diagnostics
continues with the next test.
Do the tests complete successfully?
Yes. It is not a video hardware problem. Go to Chap-
ter 3, “Finding Software Solutions.”
No. Go to step 2.
2.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
3.
Remove the computer cover.
4.
Check the system-board configuration jumpers.
See your system documentation for a list of the sys-
tem board jumpers and their settings.
Are the jumpers set correctly?
Yes. Go to step 9.
No. Go to step 5.
5.
Correct the configuration jumper settings on the
system board.
6.
Replace the computer cover, reconnect the system
to AC power, reconnect any telephone or telecom-
munication lines and turn it on.
7.
Insert the Dell Diagnostics Diskette into drive A,
and reboot the system. Run the Video Test Group
again.
Is the problem resolved?
Yes. The configuration jumpers were set incorrectly.
You have fixed the problem.
No. Go to step 8.
8.
Turn off the system, disconnect it from AC power,
and remove the computer cover. Also, disconnect
any telephone or telecommunication lines from
the computer.
9.
Determine whether a video-memory upgrade
module is installed.
See your system documentation for the location of
the video-memory upgrade module.
Is a video-memory upgrade module installed?
Yes. Go to step 10.
No. Go to step 11.
10. Reseat the video-memory upgrade module.
See your system documentation for instructions.
11. Replace the computer cover, reconnect the system
to AC power, reconnect any telephone or telecom-
munication lines and turn it on.
12. Insert the Dell Diagnostics Diskette into drive A,
and reboot the system. Run the Video Test Group
again.
Do the tests complete successfully?
Yes. The video-memory upgrade module was not
connected properly. You have fixed the problem.
No. Go to step 13.
13. Turn off the system, disconnect it from AC power,
and remove the computer cover. Also, disconnect
any telephone or telecommunication lines from
the computer.
14. Determine whether a video expansion card is
installed.
Is a video expansion card installed?
Yes. Go to step 15.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Diagnostics and Troubleshooting Guide
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
15. Remove the video expansion card, and repeat
steps 11 and 12.
Do the tests complete successfully?
Yes. The video expansion card is faulty. See Chapter
7, “Getting Help,” for instructions on obtaining tech-
nical assistance.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting the System
Board
A system board problem can result from a defective
system board component, a faulty power supply, or a
defective component connected to the system board. If an
error message indicates a system board problem, follow
these steps to find the problem:
1.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
2.
Remove the computer cover.
3.
Remove all expansion cards except the hard-disk
drive controller card and the video expansion
card (if they are installed).
4.
Replace the computer cover, reconnect the system
to AC power, and turn it on.
5.
Enter the System Setup program, and update the
system configuration information.
6.
Insert the Dell Diagnostics Diskette into drive A,
and reboot the system. Run the System Set Test
Group in the Dell Diagnostics. (See Chapter 4,
“Running the Dell Diagnostics.”)
Do the tests complete successfully?
Yes. Go to step 7.
No. Go to step 12.
7.
Remove the Dell Diagnostics Diskette from drive
A , turn off the system, disconnect it from AC
power, and remove the computer cover.
8.
Reinstall one of the expansion cards you removed
in step 3, and repeat steps 4 and 5.
See your system documentation for instructions.
9.
Insert the Dell Diagnostics Diskette into drive A,
and reboot the system. Run the System Set Test
Group again.
Do the tests complete successfully?
Yes. Go to step 10.
No. Go to step 12.
10. Turn off the system, disconnect it from AC power,
and remove the computer cover.
11. Repeat steps 7, 8, and 9 for each of the remaining
expansion cards you removed in step 3.
Have you reinstalled all of the expansion cards with-
out encountering a test failure?
Yes. Go to step 12.
No. Your expansion card is faulty. See Chapter 7,
“Getting Help,” for instructions on obtaining techni-
cal assistance.
12. Disconnect the keyboard and reboot the system.
Does the system boot successfully?
Yes. Go to step 13.
No. Go to step 14.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-9
13. Swap the keyboard with a comparable working
keyboard, and run the System Set Test Group
again.
Do the tests complete successfully?
Yes. You have fixed the problem.
No. Go to step 14.
14. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting the Diskette/
Tape Drive Subsystem
If the monitor displays a system error message indicating
a diskette drive problem during execution of either the
boot routine or the Dell Diagnostics, the problem may be
caused by any of the following conditions:
•
The system configuration settings do not match the
physical diskette/tape drive subsystem
configuration.
•
The diskette/tape drive cables are not properly con-
nected or are faulty.
•
An expansion card is interfering with proper drive
operations.
•
A diskette drive may be improperly configured.
•
The diskette drive or tape drive is faulty.
•
The computer’s power supply is not providing suffi-
cient power for the drives.
•
The computer’s diskette/tape drive logic is faulty.
In any computer that has multiple drives, a problem with
one drive can affect the entire subsystem. Therefore, the
troubleshooting procedures for the diskette/tape drive
subsystem are divided into the following subsections:
•
“Checking the Diskette/Tape Drive Subsystem”
•
“Troubleshooting a Diskette-Drive Subsystem”
•
“Troubleshooting a Non-SCSI Internal Tape Drive”
•
“Troubleshooting a SCSI Tape Drive”
Before you begin the troubleshooting procedures, com-
plete steps 1 and 2 in the next subsection, “Checking the
Diskette/Tape Drive Subsystem,” to verify that the sys-
tem configuration information is correct for the installed
diskette drive(s).
If, after completing these steps, the system boots cor-
rectly and the monitor no longer displays a system error
message, the problem is resolved. If you continue to
have problems, however, proceed with the appropriate
diskette/tape drive subsystem troubleshooting procedure.
Checking the Diskette/Tape Drive
Subsystem
To verify that the diskette/tape drive subsystem is operat-
ing properly, follow these steps:
1.
Enter the System Setup program, and verify that
the system is configured correctly for the Diskette
Drive A and Diskette Drive B categories.
See your system documentation for instructions.
2.
If the system configuration settings are incorrect,
make the necessary corrections in the System
Setup program, and then reboot the system.
3.
Insert the Dell Diagnostics Diskette into drive A,
reboot the system, and run the Diskette Drives
Test Group in the Dell Diagnostics to see whether
the diskette/tape drive subsystem now works
correctly.
See Chapter 4, “Running the Dell Diagnostics,” for
more information.
Do the tests complete successfully?
Yes. Continue with the next step in the procedure
you were performing.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting a Diskette-Drive
Subsystem
If you receive a system error message indicating a dis-
kette drive problem, insert the Dell Diagnostics Diskette
into drive A, and reboot the system by turning the com-
puter off, allowing the hard-disk drive(s) to spin down,
and turning the computer on again.
NOTE: You must leave the Dell Diagnostics Diskette in
drive A throughout this entire procedure except for steps
that specifically require you to remove it.
Diagnostics and Troubleshooting Guide
Follow these steps to troubleshoot a diskette-drive
subsystem:
1.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
2.
Remove the computer cover.
3.
Check the diskette drive cabling.
See your system documentation for the location of
your diskette drive and cabling.
The diskette drive should be connected to the drive
A connector on the diskette/tape drive interface
cable.
Is the diskette drive securely connected to the proper
diskette/tape drive interface cable connector? Is the
diskette/tape drive interface cable connector securely
connected to the interface connector on the system
board? Is the drive’s direct current (DC) power cable
firmly connected to the drive?
Yes. Go to step 5.
No. Go to step 4.
4.
Reconnect the cable connectors.
5.
Replace the computer cover, reconnect the system
to AC power, insert the Dell Diagnostics Diskette
into drive A, and reboot the system.
Does the system boot properly from the Dell Diag-
nostics Diskette?
Yes. Go to “Checking the Diskette/Tape Drive Sub-
system” found earlier in this chapter.
No. Go to step 6.
6.
Repeat steps 1 and 2, and remove all expansion
cards.
See your system documentation for instructions.
7.
Replace the computer cover, reconnect the system
to AC power, insert the Dell Diagnostics Diskette
into drive A, and reboot the system.
Does the system boot properly from the Dell Diag-
nostics Diskette?
Yes. An expansion card may be conflicting with the
diskette/tape drive logic, or you may have a faulty
expansion card. Go to “Checking the Diskette/Tape
Drive Subsystem” found earlier in this chapter.
No. Go to step 8.
8.
Repeat steps 1 and 2, and reinstall one of the
expansion cards you removed in step 6.
9.
Replace the computer cover, reconnect the system
to AC power, insert the Dell Diagnostics Diskette
into drive A, and reboot the system.
Does the system boot properly from the Dell Diag-
nostics Diskette?
Yes. Go to step 10.
No. Go to step 11.
10. Repeat steps 8 and 9 until all expansion cards
have been reinstalled or until one of the expan-
sion cards prevents the system from booting from
the Dell Diagnostics Diskette.
11. Repeat steps 1 and 2. Verify that the drive’s ter-
mination is enabled and that the drive-select
jumper is set to the DS1 position.
NOTE: Some diskette drives may require you to
remove the drive from the computer to access the ter-
mination and drive-select jumper.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
connect to boot diskette
drive (drive A)
connect to tape drive or
second diskette drive
connect to FLOPPY
connector on
system board
Checking Inside Your Computer
6-11
For information about the drive’s termination and
drive-select jumper settings, refer to the documenta-
tion for the drive.
Is the drive configured correctly?
Yes. Go to step 14.
No. Go to step 12.
12. Correct the drive-select jumper setting and ter-
minator installation.
13. Replace the computer cover, reconnect the system
to AC power, insert the Dell Diagnostics Diskette
into drive A, and reboot the system.
Does the system boot properly from the Dell Diag-
nostics Diskette?
Yes. Go to “Checking the Diskette/Tape Drive Sub-
system” found earlier in this chapter.
No. Go to step 14.
14. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting a Non-SCSI Internal
Tape Drive
In a drive configuration containing both a single diskette
drive and an internal tape drive that is not a small com-
puter system interface (SCSI) drive, the diskette drive
and the tape drive are connected, respectively, to the
drive A and drive B connectors on the diskette/tape drive
interface cable. When the internal diskette/tape drive sub-
system is configured in this manner, the Drive B category
on the System Board Options screen in the EISA Config-
uration Utility and the Diskette Drive B category in the
System Setup program must be set to Not Installed to
prevent interference with tape drive operation.
NOTE: Some systems may have an external tape drive, in
which case a special tape-drive controller card must be
installed in one of the expansion slots. The troubleshoot-
ing procedure in this subsection applies specifically to
internal tape drives.
Tape drive problems usually result from a defective tape
drive, a defective tape cartridge, or software. Follow
these steps to troubleshoot a non-SCSI internal tape
drive:
1.
Remove the tape that was in use when the prob-
lem occurred, and replace it with a tape that you
know is not defective.
Is the problem resolved?
Yes. The original tape was defective. Replace it with
a new tape. You have fixed the problem.
No. Go to step 2.
2.
Remove any installed terminate-and-stay-
resident (TSR) programs.
See “Memory-Resident Programs” in Chapter 3 for
information about unloading TSR programs.
Is the problem resolved?
Yes. The TSR program was conflicting with the tape
backup software. You have fixed the problem.
No. Go to step 3.
3.
Reinstall the tape backup software as instructed
in the tape-backup software documentation.
Is the problem resolved?
Yes. The tape backup software was corrupted. You
have fixed the problem.
No. Go to step 4.
4.
If the system contains a single diskette drive,
enter the System Setup program, and verify that
the Diskette Drive B category is set to Not
Installed.
See your system documentation for instructions.
Is the Diskette Drive B category set to Not Installed?
Yes. Go to step 6.
No. Go to step 5.
5.
Correct the Diskette Drive B category setting.
Is the problem resolved?
Yes. The system configuration information was
incorrect. You have fixed the problem.
No. Go to step 6.
Diagnostics and Troubleshooting Guide
6.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
7.
Remove the computer cover.
8.
Check the interface cable connections to the tape
drive and to the interface connector on the system
board or the controller card (if one is installed).
Check the DC power cable connection to the tape
drive.
Are the cables firmly connected?
Yes. Go to step 10.
No. Go to step 9.
9.
Reseat the cable connectors, replace the computer
cover, reconnect the system to AC power, and
turn it on.
Is the problem resolved?
Yes. The connections were loose. You have fixed the
problem.
No. Go to step 10.
10. Turn off the system, disconnect it from AC power,
and remove the computer cover.
11. Remove the tape drive, and ensure that the input/
output (I/O) address and IRQ jumper settings do
not conflict with any other device’s settings.
See “Avoiding Interrupt Assignment Conflicts” in
Chapter 3. For information on setting the jumpers,
see the documentation for the tape drive.
Are the drive’s jumpers positioned correctly?
Yes. Go to step 13.
No. Go to step 12.
12. Correct the drive’s jumper settings according to
the documentation for the tape drive, and rein-
stall the tape drive.
13. Replace the computer cover, reconnect the system
to AC power, reconnect any telephone or telecom-
munication lines, and turn on the computer.
Is the problem resolved?
Yes. The IRQ jumper settings were incorrect. You
have fixed the problem.
No. See Chapter 7, “Getting Help” for instructions
on obtaining technical assistance.
Troubleshooting a SCSI Tape Drive
A SCSI tape drive can be either an internal device
installed in one of the externally accessible drive bays or
an external device that attaches to a SCSI host adapter
connector on the back panel of the computer. In either
case, the SCSI tape drive is controlled by a SCSI host
adapter installed in the computer, which may also control
other SCSI devices connected to one or more SCSI
cables. SCSI devices sometimes require device drivers
for the particular operating system being used by the
computer system.
Tape drive problems often result from a defective tape
drive, a defective tape cartridge, or software. Follow
these steps to troubleshoot a SCSI tape drive:
1.
Remove the tape that was in use when the prob-
lem occurred, and replace it with a tape that you
know is not defective.
Is the problem resolved?
Yes. The original tape was defective. Replace it with
a new tape. You have fixed the problem.
No. Go to step 2.
2.
Remove any installed TSR programs.
See “Memory-Resident Programs” in Chapter 3 for
information about unloading TSR programs.
Is the problem resolved?
Yes. The TSR program was conflicting with the tape
backup software. You have fixed the problem.
No. Go to step 3.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-13
3.
Verify that any required SCSI device drivers are
installed on the hard-disk drive and are config-
ured correctly.
If the computer system is using a built-in SCSI host
adapter or a Dell Advanced SCSI Host (DASH) Bus
Adapter card, see the SCSI Device Driver Installa-
tion and Configuration Guide for instructions on
installing and configuring the SCSI device drivers.
For any other type of SCSI host adapter card, see the
documentation that accompanied the host adapter
card.
Are the drivers installed and configured correctly?
Yes. The SCSI device drivers were installed or con-
figured incorrectly or were corrupted. You have
fixed the problem.
No. Go to step 4.
4.
Reinstall the tape backup software as instructed
in the tape-backup software documentation.
Is the problem resolved?
Yes. The tape backup software was corrupted. You
have fixed the problem.
No. Go to step 5.
5.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
6.
Remove the computer cover.
7.
Check the SCSI cable connections to the tape
drive and to the SCSI host adapter connector. If
the tape drive is an internal device, check the DC
power cable connection to the tape drive.
Are the cables firmly connected?
Yes. Go to step 9.
No. Go to step 8.
8.
Reseat the cable connectors, replace the computer
cover, reconnect the system to AC power, and
turn it on.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 9.
9.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Then remove the
computer cover.
10. Remove the tape drive. Then verify that the tape
drive is configured for a unique SCSI identifica-
tion (ID) number and that the tape drive’s
termination is enabled or disabled as appropriate.
See the documentation for the tape drive for instruc-
tions on selecting the SCSI ID and enabling or
disabling termination.
Is the tape drive configured correctly?
Yes. Go to step 13.
No. Go to step 11.
11. Reconfigure the tape drive’s SCSI ID and termi-
nation settings as appropriate. Reinstall the tape
drive, replace the computer cover, reconnect the
system to AC power, and turn it on.
Is the problem resolved?
Yes. The tape drive was configured incorrectly. You
have fixed the problem.
No. Go to step 12.
12. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Then remove the
computer cover.
13. Replace the SCSI cable that connects the tape
drive to the SCSI host adapter connector.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Diagnostics and Troubleshooting Guide
14. Replace the computer cover, reconnect the system
to AC power, reconnect any telephone or telecom-
munication lines, and turn on the computer.
Is the problem resolved?
Yes. You have fixed the problem.
No. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting Hard-Disk
Drives
Hard-disk drive problems can be caused by a number of
conditions, including problems with the drive itself, a
hard-disk drive controller card, the optional SCSI back-
plane board, the SCSI host adapter, or an interface cable.
This section is further subdivided into three procedures
for troubleshooting hard-disk drives:
•
“Troubleshooting IDE Hard-Disk Drives”
•
“Troubleshooting SCSI Hard-Disk Drives in a Sys-
tem Without a SCSI Backplane Board”
•
“Troubleshooting SCSI Hard-Disk Drives in a Sys-
tem With a SCSI Backplane Board”
Troubleshooting IDE Hard-Disk Drives
Use the following procedure to troubleshoot a hard-disk
drive problem if your system includes one or more inte-
grated drive electronics (IDE) hard-disk drives.
1.
Boot the system from a diskette, enter the System
Setup program, and verify that the hard-disk
drive categories are set correctly for the installed
hard-disk drives.
Refer to your system documentation for the correct
settings of these categories. You can also use the
automatic drive-type detect feature to correctly set
the drive-type number and the drive parameters for
each drive.
Are the system configuration settings correct for the
installed hard-disk drive?
Yes. Go to step 3.
No. Go to step 2.
2.
Correct the system configuration settings, and
reboot the system.
Is the problem resolved?
Yes. The system configuration settings were set
incorrectly. You have fixed the problem.
No. Go to step 3.
3.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
4.
Remove the computer cover.
5.
Check the hard-disk drive interface cable connec-
tions to the drive and to the IDE connector on the
system board or the controller card (if one is
installed). Check the DC power cable connection
to the drive.
Are the cables firmly connected?
Yes. Go to step 7.
No. Go to step 6.
6.
Reseat the cable connectors, replace the computer
cover, reconnect the system to AC power, and
turn it on.
Is the problem resolved?
Yes. The cables were loose. You have fixed the
problem.
No. Go to step 7.
7.
Turn off the system, disconnect it from AC power,
and remove the computer cover.
8.
Remove the hard-disk drive.
CAUTION: This troubleshooting procedure can
destroy data stored on the hard-disk drive. Before
you proceed, make sure you have backed up all the
files on your hard-disk drive.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-15
9.
Check the hard-disk drive’s jumpers and the con-
troller card’s jumpers (if a controller card is
installed). (For an Industry-Standard Architec-
ture [ISA] card, check the settings on the card
itself; for an Extended Industry-Standard Archi-
tecture [EISA] card, check the settings through
the EISA Configuration Utility.)
For a description of the jumper settings for the drive
or controller card, see the documentation for the
drive or controller card.
Are the jumpers positioned correctly?
Yes. Go to step 11.
No. Go to step 10.
10. Correct the jumper settings for the drive and/or
controller card as instructed by the documenta-
tion for the drive and reinstall the hard-disk
drive.
11. Replace the computer cover, reconnect the system
to AC power, reconnect any telephone or telecom-
munication lines to the computer, and turn on the
computer.
12. Listen for the drive spinning up after the power
supply turns on.
Can you hear the drive spinning up?
Yes. Go to step 13.
No. Go to step 14.
13. Partition and logically format the hard-disk
drive. If possible, restore the files to the drive.
To partition and logically format the drive, see the
documentation for the computer’s operating system.
Is the problem resolved?
Yes. The hard-disk drive’s file structure was proba-
bly corrupt. You have fixed the problem.
No. Go to step 14.
14. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
Troubleshooting SCSI Hard-Disk Drives
in a System Without a SCSI Backplane
Board
Use the following procedure to troubleshoot a hard-disk
drive problem if your system includes one or more SCSI
hard-disk drives and does not contain a SCSI backplane
board.
1.
Boot the system from a diskette, and enter the
System Setup program.
Are both of the hard-disk drive categories set to
None?
Refer to your system documentation for more infor-
mation about the hard-disk drive categories.
Yes. Go to step 3.
No. Go to step 2.
2.
Change both categories to None, and reboot the
system.
Is the problem resolved?
Yes. The system configuration settings were set
incorrectly. You have fixed the problem.
No. Go to step 3.
3.
Verify that any required SCSI device drivers are
installed and configured correctly.
If the system is using the built-in SCSI host adapter
or the DASH Bus Adapter card, see the SCSI Device
Driver Installation and Configuration Guide to
determine which drivers are required and how they
should be installed and configured.
Are the required SCSI device drivers installed and
configured correctly?
Yes. Go to step 5.
No. Go to step 4.
CAUTION: This troubleshooting procedure can
destroy data stored on the hard-disk drive. Before
you proceed, make sure you have backed up all the
files on your hard-disk drive.
Diagnostics and Troubleshooting Guide
4.
Reinstall and/or reconfigure the required SCSI
device drivers. Then reboot the system.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 5.
5.
Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer.
6.
Remove the computer cover.
7.
Check the SCSI cable connection to the drive and
to the SCSI host adapter. Check the DC power
cable connection to the drive.
Are the cables firmly connected?
Yes. Go to step 9.
No. Go to step 8.
8.
Reseat the cable connectors, replace the computer
cover, reconnect the system to AC power, recon-
nect any telephone or telecommunication lines to
the computer, and turn it on.
Is the problem resolved?
Yes. The cables were loose. You have fixed the
problem.
No. Go to step 9.
9.
Turn off the system, disconnect it from AC power,
disconnect any telephone or telecommunication
lines from the computer, and remove the com-
puter cover.
10. Remove the hard-disk drive.
11. Verify that the hard-disk drive is configured for a
unique SCSI ID and that termination is enabled
or disabled as appropriate.
See the documentation for the hard-disk drive for
instructions on selecting the SCSI ID and enabling or
disabling termination.
Is the hard-disk drive configured correctly?
Yes. Go to step 13.
No. Go to step 12.
12. Reconfigure the hard-disk drive’s SCSI ID and
termination settings as appropriate. Reinstall the
hard-disk drive. Replace the computer cover,
reconnect the system to AC power, and turn it on.
Is the problem resolved?
Yes. The hard-disk drive was configured incorrectly.
You have fixed the problem.
No. Go to step 13.
13. Replace the SCSI cable connecting the drive to
the SCSI host adapter. Replace the computer
cover, reconnect the system to AC power, recon-
nect any telephone or telecommunication lines to
the computer.and turn it on.
Is the problem resolved?
Yes. The SCSI cable was faulty. You have fixed the
problem.
No. Go to step 14.
14. Partition and logically format the hard-disk
drive. If possible, restore the files to the drive.
To partition and logically format the drive, see the
documentation for the computer’s operating system.
Is the problem resolved?
Yes. The hard-disk drive’s file structure was proba-
bly corrupt. You have fixed the problem.
No. Go to step 15.
15. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Checking Inside Your Computer
6-17
Troubleshooting SCSI Hard-Disk Drives
in a System With a SCSI Backplane
Board
Use the following procedure to troubleshoot a hard-disk
drive problem if your system contains an optional SCSI
backplane board.
1.
Boot the system from a diskette, and enter the
System Setup program.
Are both of the hard-disk drive categories set to
None?
Yes. Go to step 3.
No. Go to step 2.
2.
Change both categories to None, and reboot the
system.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 3.
3.
Verify that any required SCSI device drivers are
installed and configured correctly.
If the system is using the built-in SCSI host adapter
or the DASH Bus Adapter card, see the SCSI Device
Driver Installation and Configuration Guide to
determine which drivers are required and how they
should be installed and configured.
Are the required SCSI device drivers installed and
configured correctly?
Yes. Go to step 5.
No. Go to step 4.
4.
Reinstall and/or reconfigure the required SCSI
device drivers. Then reboot the system.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 5.
5.
Determine whether the system has a Dell SCSI
Array (DSA) controller card.
Does the system have a DSA controller card?
Yes. Go to step 6.
No. Go to step 15.
6.
Run the DSA Manager program to see if it can
determine which hard-disk drive is faulty.
See the Dell SCSI Array User’s Guide for instruc-
tions on running the DSA Manager.
Can the DSA Manager identify the faulty drive?
Yes. Go to step 26.
No. Go to step 7.
7.
Remove the computer cover.
8.
Check the hard-disk drive failure indicator on the
front of each hard-disk drive carrier.
Is the hard-disk drive failure indicator on or blinking
for any of the drive carriers?
Yes. Go to step 26.
No. Go to step 9.
9.
Check the online indicator on the front of each
hard-disk drive carrier.
Is the online indicator on for each drive carrier?
Yes. Go to step 13.
No. Go to step 10.
10. Press the release button on the front of the drive
carrier.
Does the online indicator blink and then turn on?
Yes. The drive carrier was not installed into the
array. You have fixed the problem.
No. Go to step 11.
CAUTION: This troubleshooting procedure can
destroy data stored on the hard-disk drive. Before
you proceed, make sure you have backed up all the
files on your hard-disk drive.
CAUTION: See “Protecting Against Electro-
static Discharge” in the safety instructions at
the front of this guide.
Diagnostics and Troubleshooting Guide
11. Check the SCSI ID switch settings on the back of
the SCSI backplane board to verify that each
drive bay is configured for a unique SCSI ID and
that none of the SCSI IDs conflict with the SCSI
ID for the SCSI host adapter.
See your system documentation for the recom-
mended SCSI ID switch settings.
Is the drive bay configured for a unique SCSI ID?
Yes. Go to step 13.
No. Go to step 12.
12. Change the SCSI ID switch settings so that each
drive bay is configured for a unique SCSI ID that
does not conflict with the SCSI host adapter. Turn
off the computer, wait a few seconds, then turn it
back on.
Is the problem resolved?
Yes. The drive bay was configured incorrectly. You
have fixed the problem.
No. Go to step 13.
13. Remove the drive carrier from its bay, and check
all cable connections between the drive and the
drive carrier. Also make sure that the SCSI ID
cable is oriented correctly and is installed on the
correct set of pins on the drive. Reinstall the drive
carrier in its bay. Verify that a jumper plug is not
installed on the READ_ONLY jumper pins on the
interface board. Then press the release button on
the front of the drive carrier.
See your system documentation for information on
cable connections and the correct installation of the
SCSI ID cable.
Does the online light-emitting diode (LED) blink
and then stay on?
Yes. The drive carrier was not firmly seated in the
connector on the SCSI backplane board, or one of
the cables in the drive carrier was installed incor-
rectly. You have fixed the problem.
No. Go to step 14.
14. Remove the drive carrier and install it in another
drive bay.
Is the problem resolved?
Yes. The SCSI backplane board has a defective con-
nector. See Chapter 7, “Getting Help,” for
instructions on obtaining technical assistance.
No. Go to step 21.
15. Check the online indicator on the front of each
hard-disk drive carrier.
Is the online indicator on for each drive carrier?
Yes. Go to step 19.
No. Go to step 17.
16. Check the SCSI ID switch settings on the back of
the SCSI backplane board to verify that each
drive bay is configured for a unique SCSI ID and
that none of the SCSI IDs conflict with the SCSI
ID for the SCSI host adapter.
See your system documentation for the recom-
mended SCSI ID switch settings.
Is the drive bay configured for a unique SCSI ID?
Yes. Go to step 19.
No. Go to step 18.
17. Change the SCSI ID switch settings so that each
drive bay is configured for a unique SCSI ID that
does not conflict with the SCSI host adapter. Turn
off the computer, wait a few seconds, then turn it
back on.
Is the problem resolved?
Yes. The drive bay was configured incorrectly. You
have fixed the problem.
No. Go to step 19.
CAUTION: Removing the jumper plug from
the READ_ONLY jumper pins and then rein-
stalling the drive with the system turned on
will cause all data on the drive to be erased. To
preserve the data on the drive, either turn off
the system, reinstall the drive, and then turn
on the system, or do not reinstall the drive.
Checking Inside Your Computer
6-19
18. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Also, disconnect
any telephone or telecommunication lines from
the computer. Remove the computer cover if it is
not already removed.
19. Remove a drive carrier from its bay, and check all
cable connections between the drive and the drive
carrier. Also make sure that the SCSI ID cable is
oriented correctly and is installed on the correct
set of pins on the drive. Reinstall the drive carrier
in its bay. Repeat this procedure for all the other
drive carriers. Reconnect the system to AC
power, and turn it on.
See your system documentation for information on
cable connections and the correct installation of the
SCSI ID cable.
Is the problem resolved?
Yes. A drive carrier was not firmly seated in its con-
nector on the SCSI backplane board. You have fixed
the problem.
No. Go to step 21.
20. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources.
21. Check the SCSI cable connections to the SCSI
backplane board and to the SCSI host adapter.
Check the DC power cable connection to the
SCSI backplane board.
See your system documentation for the location of
the cable connectors on the SCSI backplane board.
Are the cables firmly connected?
Yes. Go to step 24.
No. Go to step 23.
22. Reseat the cable connectors, reconnect the com-
puter and peripherals to their AC power sources,
and turn them on.
Is the problem resolved?
Yes. The cable connections were faulty. You have
fixed the problem.
No. Go to step 24.
23. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources.
24. Replace the SCSI cable connecting the SCSI
backplane board to the SCSI host adapter.
Reconnect the system to AC power, and turn it
on.
Is the problem resolved?
Yes. The SCSI cable was faulty. You have fixed the
problem.
No. Go to step 26.
25. Partition and logically format the hard-disk
drive. If possible, restore your files to the drive.
To partition and logically format the drive, see the
documentation for the computer’s operating system.
Is the problem resolved?
Yes. The hard-disk drive format was corrupted. You
have fixed the problem.
No. Go to step 26.
26. See Chapter 7, “Getting Help,” for instructions
on obtaining technical assistance.
This chapter describes the tools Dell provides to help
you when you have a problem with your computer sys-
tem. It also tells you when and how to call Dell for
technical or customer assistance in the following
situations:
•
If you have a technical problem, read the next sec-
tion, “Technical Assistance.”
•
If you are looking for information about a specific
subject or about Dell’s services, read “Help Tools”
found later in this chapter.
•
If you have a problem with your order, read “Prob-
lems With Your Order” found later in this chapter.
•
If you need to return an item for warranty repair or
credit, read “Returning Items for Warranty Repair or
Credit” found later in this chapter.
•
If you would like to place an order or need informa-
tion about additional products available from Dell,
call Dell at the appropriate telephone number listed
in “Dell Contact Numbers” found later in this
chapter.
Technical Assistance
If you need assistance with a technical problem, perform
the following steps:
1.
Review the Frequently Asked Questions cards, if
applicable.
Two information cards, one titled Frequently Asked
Questions About Your Dell System and another titled
Frequently Asked Questions About MS-DOS and
Microsoft Windows, come with certain Dell systems.
NOTE: You may also find these questions and
answers in the Dell Q&A for certain systems. For
more information, see “Dell Q&A” found later in
this chapter.
2.
Review the remaining documentation that accom-
panied your Dell system.
To decide which document has the answers you
need, consult the Preface of your system
documentation.
3.
Run the diagnostics for your Dell system.
See Chapter 4, “Running the Dell Diagnostics,” for
instructions on using the Dell Diagnostics program.
4.
Make a copy of the Diagnostics Checklist (found
later in this chapter), and fill it out.
NOTE: Save the Diagnostics Checklist in this chap-
ter as a master so you can use it to make copies as
needed.
On your copy of the Diagnostics Checklist, docu-
ment any error messages or beep codes as they occur
so you can inform the Dell technician of them.
Describe what you were doing when the error
occurred. Note the steps you have taken to solve the
problem.
5.
Use the AutoTech service for help with installa-
tion and troubleshooting procedures.
For instructions on using the AutoTech service, see
“AutoTech Service” found later in this chapter
6.
If the preceding steps have not resolved the prob-
lem and you need to talk to a Dell technician, you
can call Dell’s customer technical support service.
Before you call Dell, convert your service tag num-
ber into an express service code. When prompted by
Dell’s automated telephone system, enter the express
service code to route your call directly to the proper
support personnel.
Diagnostics and Troubleshooting Guide
If you did not convert your service tag number to an
express service code the first time you turned on the
system, do it before you call Dell for technical assis-
tance. Find the Express Service Code icon in the
Dell Accessories folder or program group. Double-
click the icon and follow the directions.
NOTE: Dell’s Express Service may not be available
in all countries.
For instructions on using the technical support ser-
vice, see “Technical Support Service” and “Before
You Call” found later in this chapter.
Help Tools
Dell provides a number of tools to assist you. Table 7-1
lists subjects you may want information about, tasks you
may want to perform, and the tool(s) you can use for
help. Each tool is described later in this section.
Frequently Asked Questions Cards
Dell anticipates some of your questions by providing two
information cards with certain Dell systems. One card is
Table 7-1. Help Tools
Subject or Task
Tool
BIOS revisions
TechConnect BBS
Frequently asked questions
Frequently Asked Questions cards, Dell Q&A, AutoTech
service
Information about Dell, its products, and its service
and support policies
TechFax service, TechConnect BBS, World Wide Web on
the Internet
Installation instructions
System documentation, technical support service, AutoTech
service
Interrupt maps
TechFax service
Ordering parts
Technical support service, TechConnect BBS
Software update information
TechFax service
System board layouts
TechFax service, system documentation
Technical notes on system compatibility and revisions
TechFax service
Technical training class information
TechFax service
Technical specifications
TechFax service, system documentation
Troubleshooting, step-by-step instructions
System documentation, Dell Diagnostics program, Auto-
Tech service
Unresolved problems requiring assistance from a Dell
technician
Technical support service, TechConnect BBS
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviations and acronyms list that precedes the
Index.
titled Frequently Asked Questions About Your Dell Sys-
tem and the other is titled Frequently Asked Questions
About MS-DOS and Microsoft Windows. Be sure to
review these cards when you have a question about your
system, MS-DOS, or the Windows 3.x or Windows 95
operating system.
Dell Q&A
The Dell Q&A, a Windows-based online help file that
answers questions that are often asked by Dell computer
users, is included with certain Dell systems that were pur-
chased with the Dell-installed Windows 3.x or Windows
95 operating system.
To view the Dell Q&A, open the Dell Accessories pro-
gram group or folder and double-click on the Dell Q&A
icon. If you need further instructions on using the Dell
Q&A, click Help from the Dell Q&A button bar.
System Documentation
The system documentation shipped with your system
includes information about installing hardware, software
support utilities, and video drivers and about using the
System Setup program. For certain Dell systems, the sys-
tem documentation is provided online and is located in
the Dell Accessories program group or folder.
World Wide Web on the Internet
Dell can be accessed electronically on the Internet via a
World Wide Web site, a file transfer protocol (FTP) site,
and electronic mail (e-mail) using the following
addresses:
•
World Wide Web
http://www.dell.com/
http://www.dell.com/intl/apcc/ (for Asian/Pacific
countries only)
http://www.dell.com/euro/ (for Europe only)
•
Anonymous FTP
ftp.dell.com/
Log in as user: anonymous, and use your
e-mail address as your password.
•
Electronic Support Service
[email protected]
[email protected] (for Asian/Pacific countries
only)
•
Electronic Quote Service
[email protected]
[email protected] (for Asian/Pacific coun-
tries only)
•
Electronic Information Service
[email protected]
Commercial Online Service
Dell can be accessed electronically via CompuServe® by
typing GO DELL.
Dell Diagnostics Program
Every Dell system comes with the Dell Diagnostics, a
program that can help you determine what is wrong with
the system when it does not operate correctly. This pro-
gram provides valuable information for you and for Dell
technicians should you need to call Dell.
See Chapter 4, “Running the Dell Diagnostics,” for
instructions on using the diagnostics. You can use this
diagnostic program to test major components or devices
in the system, if the system can boot.
AutoTech Service
Dell’s automated technical support service—AutoTech—
provides recorded answers to the questions most fre-
quently asked by Dell customers.
When you call AutoTech, you use your touch-tone tele-
phone to select the subjects that correspond to your
questions. You can even interrupt an AutoTech session
and continue the session later. The code number that the
AutoTech service gives you allows you to continue your
session where you ended it.
The information available through AutoTech includes:
•
Specifications and prices for Dell systems currently
on sale
•
Installation instructions for Dell systems and
peripherals
Diagnostics and Troubleshooting Guide
•
Answers to questions about MS-DOS and the
Microsoft Windows 95 and Windows 3.x operating
systems
•
Help in troubleshooting your Dell system
The AutoTech service is available 24 hours a day, seven
days a week. You can also access this service through the
technical support service. For the telephone number to
call, see “Dell Contact Numbers” found later in this
chapter.
NOTE: AutoTech is not always available in all locations
outside the continental U.S. Please call your local Dell
representative for information on availability.
TechFax Service
Dell takes full advantage of fax technology to serve you
better. Twenty-four hours a day, seven days a week, you
can call the Dell TechFax line toll-free for all kinds of
technical information.
Using a touch-tone phone, you can select from a full
directory of topics. The technical information you request
is sent within minutes to the fax number you designate.
TechFax information includes:
•
Interrupt maps, system board layouts, and
specifications.
•
Technical notes on system compatibility and
revisions.
•
News on updates for operating systems and applica-
tion programs.
•
Descriptions of available technical training classes.
For Dell-certified technicians, TechFax offers infor-
mation such as parts lists, drawings, and maintenance
and repair data.
For the TechFax telephone number, see “Dell Contact
Numbers” found later in this chapter.
NOTE: TechFax is not always available in all locations
outside the continental U.S. Please call your local Dell
representative for information on availability.
TechConnect BBS
Use your modem to access Dell’s TechConnect Bulletin
Board Service (BBS) 24 hours a day, seven days a week.
The service is menu-driven and fully interactive. The
modem settings for the BBS are 8 bit, no parity, 1 stop
bit.
You can use the BBS to do the following:
•
Send questions to a Dell technician
•
Request a follow-up call or leave a message for a
Dell technical support specialist
•
Order parts
•
Download basic input/output system (BIOS) and
video driver upgrades
•
Download updates
For the BBS telephone number, see “Dell Contact Num-
bers” found later in this chapter.
NOTE: The TechConnect BBS is not always available in
all locations outside the continental U.S. Please call your
local Dell representative for information on availability.
Automated Order-Status System
You can call this automated service to check on the status
of any Dell products that you have ordered. A recording
prompts you for the information needed to locate and
report on your order. For the telephone number to call,
see “Dell Contact Numbers” found later in this chapter.
NOTE: The Automated Order-Status System is not
always available in all locations outside the continental
U.S. Please call your local Dell representative for infor-
mation on availability.
Technical Support Service
Dell’s industry-leading hardware technical support ser-
vice is open 24 hours a day, seven days a week. At any
hour of any day, a Dell technical expert is ready with the
answers to your questions about Dell hardware.
Our technical support staff pride themselves on their
track record: more than 90 percent of all problems and
questions are taken care of in just one toll-free call, usu-
ally in less than ten minutes. When you call, our experts
can refer to records we keep on your specific Dell system
to better understand your particular question. Our techni-
cal support staff use computer-based diagnostics to
provide fast, accurate answers to your questions.
To contact Dell’s technical support service, first refer to
the section titled “Before You Call” and then call the
number for your country as listed in “Dell Contact Num-
bers” found later in this chapter. (For information about
receiving technical assistance in the U.K., refer to the
Placing a Service Call card that came with your system.)
NOTE: Technical support services may vary outside the
continental U.S. Contact your local Dell representative
for more information.
Problems With Your Order
If you have a problem with your order, such as missing
parts, wrong parts, or incorrect billing, contact Dell Com-
puter Corporation for customer assistance. Have your
invoice or packing slip handy when you call. For the tele-
phone number to call, see “Dell Contact Numbers” found
later in this chapter.
Product Information
If you need information about additional products avail-
able from Dell Computer Corporation, or if you would
like to place an order, a sales specialist will be glad to
help. For the telephone number to call, see “Dell Contact
Numbers” found later in this chapter.
Returning Items for Warranty
Repair or Credit
Prepare all items being returned, whether for repair or
credit, as follows:
1.
Call Dell to obtain an authorization number, and
write it clearly and prominently on the outside of
the box.
For the telephone number to call, see “Dell Contact
Numbers” found later in this chapter.
2.
Include a copy of the invoice and a letter describ-
ing the reason for the return.
3.
Include a copy of the Diagnostics Checklist indi-
cating the tests you have run and any error
messages reported by the Dell Diagnostics.
4.
Include any accessories that belong with the
item(s) being returned (power cables, software
diskettes, guides, and so on) if the return is for
credit.
5.
Pack the equipment to be returned in the original
(or equivalent) packing materials.
You are responsible for paying shipping expenses.
You are also responsible for insuring any product
returned, and you assume the risk of loss during
shipment to Dell Computer Corporation. Collect on
delivery (C.O.D.) packages are not accepted.
Returns that are missing any of the preceding require-
ments will be refused at our receiving dock and returned
to you.
Before You Call
Keep a record of your diagnostic and troubleshooting
activities by photocopying the Diagnostics Checklist in
Figure 7-1 and filling it out whenever you experience a
problem with the system.
NOTE: Be sure to save the checklist in Figure 7-1 as a
master, so you can use it to make copies as needed. The
checklist can also be accessed in “Diagnostics Check-
list” in the online System User’s Guide.
Diagnostics and Troubleshooting Guide
If you need to call Dell Computer Corporation for assis-
tance, you will be able to inform the support technician of
the actions you have taken to resolve the problem. If you
must return a piece of hardware to Dell, a technician will
assign a Return Material Authorization Number. Record
the number on the checklist, and include the completed
checklist in the shipping box.
Dell’s technical support staff uses computer-based diag-
nostics to provide fast, accurate answers to your
questions. When you call, the technical support staff
refers to records regarding your specific Dell system to
better understand your particular question.
NOTE: Have your express service code ready when you
call. The code helps Dell’s automated support telephone
system direct your call more efficiently.
If possible, turn your system on before you call Dell for
technical assistance and call from a telephone at or near
the system. You may be asked to type some commands at
the keyboard, relay detailed information during opera-
tions, or try other troubleshooting steps possible only at
the system itself.
Make sure the system’s user documentation is available.
You should also have a flat-blade screwdriver or a quar-
ter-inch nut driver available.
WARNING: If you need to remove the computer
cover, be sure to first disconnect the computer sys-
tem’s power and modem cables from all electrical
outlets.
Name: ______________________________________________________________Date: ____________________
Address: _____________________________________________________________Phone number: ____________
Service tag (bar code on the back of the computer): ___________________________________________________
Express service code: ___________________________________________________________________________
Return Material Authorization Number (if provided by Dell support technician): ____________________________
Operating system and version: ____________________________________________________________________
Peripherals: ___________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
PC Cards or expansion cards:______________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
Are you connected to a network? yes no
Network, version, and network card: _______________________________________________________________
Programs and versions: __________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
See your operating system documentation to determine the contents of the system’s start-up files. If the computer is
connected to a printer, print each file. Otherwise, record the contents of each file before calling Dell.
Error message or beep code: ______________________________________________________________________
Description of problem and troubleshooting procedures you performed: ___________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
Diagnostics Checklist
Diagnostics and Troubleshooting Guide
Figure 7-1. Diagnostics Checklist
Dell Contact Numbers
When you need to contact Dell, use the telephone num-
bers and codes provided in Tables 7-2 and 7-3. Table 7-2
provides the various codes required to make long-
distance and international calls. Table 7-3 provides local
telephone numbers, area codes, and toll-free numbers, if
applicable, for each department or service available in
various countries around the world. If you are making a
direct-dialed call to a location outside of your local tele-
phone service area, determine which codes to use (if any)
in Table 7-2 in addition to the local numbers provided in
Table 7-3. For example, to place an international call
from Paris, France, to Bracknell, England, dial the inter-
national access code for France followed by the country
code for the U.K., the city code for Bracknell, and then
the local number as shown in the following illustration.
To place a long-distance call within your own country,
use area codes instead of international access codes,
country codes, and city codes. For example, to call Paris,
France from Montpellier, France, dial the area code plus
the local number as shown in the following illustration.
The codes required depend on where you are calling from
as well as the destination of your call; in addition, each
country has a different dialing protocol. If you need assis-
tance in determining which codes to use, contact a local
or an international operator.
NOTE: Toll-free numbers are for use only within the
country for which they are listed. Area codes are most
often used to call long distance within your own country
(not internationally)—in other words, when your call
originates in the same country you are calling.
00
International
Access Code
(in France)
1344
City Code
(Bracknell)
________
Local
Number
44
Country
Code
(for U.K.)
01
Area Code
(for Paris from
outside Paris)
________
Local
Number
Table 7-2. International Dialing Codes
Country (City)
International
Access Code
Country Code
City Code
Australia (Sydney)
0011
61
2
Austria (Vienna)
900
43
1
Belgium (Brussels)
00
32
2
Brunei
—
673
—
Canada (North York, Ontario)
011
—
Not required
Chile (Santiago)
—
56
2
China (Beijing)
—
86
10
Czech Republic (Prague)
00
420
2
Denmark (Horsholm)
009
45
Not required
Finland (Helsinki)
990
358
9
France (Paris) (Montpellier)
00
33
(1) (4)
Germany (Langen)
00
49
6103
Hong Kong
001
852
Not required
Ireland (Bray)
16
353
1
Italy (Milan)
00
39
2
Japan (Kawasaki)
001
81
44
Korea (Seoul)
001
82
2
Luxembourg
00
352
—
Macau
—
853
Not required
Malaysia (Penang)
00
60
4
Mexico (Colonia Granada)
95
52
5
Netherlands (Amsterdam)
00
31
20
New Zealand
00
64
—
Norway (Lysaker)
095
47
Not required
Poland (Warsaw)
011
48
22
Singapore (Singapore)
005
65
Not required
South Africa (Johannesburg)
09/091
27
11
Diagnostics and Troubleshooting Guide
Spain (Madrid)
07
34
1
Sweden (Upplands Vasby)
009
46
8
Switzerland (Geneva)
00
41
22
Taiwan
002
886
—
Thailand
001
66
—
U.K. (Bracknell)
010
44
1344
U.S.A. (Austin, Texas)
011
1
Not required
Table 7-2. International Dialing Codes (continued)
Country (City)
International
Access Code
Country Code
City Code
Table 7-3. Dell Contact Numbers
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Australia
(Sydney)
Customer Technical Support (Dell Dimension® systems only) . . . . . . . . . . . 1-300-65-55-33
Customer Technical Support (Other systems) . . . . . . . . . . . . . . . . . toll free: 1-800-808-378
Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-819-339
Corporate Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-808-385
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-808-312
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-818-341
Austria*
(Vienna)
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491 04 0
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0660-8779
Belgium*
(Brussels)
Customer Technical Support . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . .4819288
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0800 16884
SalesFax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . .4819299
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . .4819100
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . .4819299
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
NOTE: Customers in
Brunei call Malaysia for
sales, customer, and tech-
nical assistance.
Customer Technical Support
(Dell Dimension systems only) (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4946
Customer Technical Support (Other systems) (Penang, Malaysia). . . . . . . . . . . . . . . 810 4966
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Transaction Sales (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4955
Canada
(North York, Ontario)
NOTE: Customers in
Canada call the
U.S.A. for access to
TechConnect BBS.
Automated Order-Status System . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-433-9014
AutoTech (Automated technical support). . . . . . . . . . . . . . . . . . . . . toll free: 1-800-247-9362
Customer Care (From outside Toronto). . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-387-5759
Customer Care (From within Toronto) . . . . . . . . . . . . . . . 416 . . . . . . . . . . . . . . . . 758-2400
Customer Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-847-4096
Sales (Direct Sales—from outside Toronto) . . . . . . . . . . . . . . . . . . . toll free: 1-800-387-5752
Sales (Direct Sales—from within Toronto). . . . . . . . . . . . . 416 . . . . . . . . . . . . . . . . 758-2200
Sales (Federal government, education, and medical) . . . . . . . . . . . . . toll free: 1-800-567-7542
Sales (Major Accounts) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-387-5755
TechConnect BBS (Austin, Texas, U.S.A.). . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-8528
TechFax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-950-1329
Chile
(Santiago)
NOTE: Customers in
Chile call the U.S.A for
sales, customer, and tech-
nical assistance.
Sales, Customer Support, and Technical Support . . . . . . . . . . . . . toll free: 1230-020-4823
China
(Beijing)
NOTE: Customers in
China call Malaysia for
customer assistance.
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6846 1122 (extensions 8309 to 8314)
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Diagnostics and Troubleshooting Guide
Czech Republic*
(Prague)
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . 8728 221
Customer Service and Sales. . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . . 879250
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . .66710274
Denmark*
(Horsholm)
Customer Care, Technical Support, and Sales. . . . . . . . . . . . . . . . . . . toll free: 800 171 62
Finland*
(Helsinki)
Customer Support and Technical Support . . . . . . . . . . . . . . . . . . . . . toll free: 0800-534 55
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 0800-33 55
France*
(Paris/Montpellier)
Technical Support (Paris) . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . 47 62 68 90
Technical Support (Montpellier) . . . . . . . . . . . . . . . . . . . 04 . . . . . . . . . . . . . . . 67 06 62 86
Customer Care (Major Accounts) (Paris) . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . 47 62 69 39
Customer Care (VAR Accounts) (Paris) . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . 47 62 69 26
Customer Care (Direct Sales) (Paris) . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . 47 62 69 76
TechFax (Montpellier) . . . . . . . . . . . . . . . . . . . . . . . . . . . 04 . . . . . . . . . . . . . . . 67 22 53 11
TechConnect BBS (Montpellier) . . . . . . . . . . . . . . . . . . . 04 . . . . . . . . . . . . . . . 67 22 53 04
Switchboard (Paris). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . 47 62 68 50
Switchboard (Montpellier). . . . . . . . . . . . . . . . . . . . . . . . 04 . . . . . . . . . . . . . . . 67 06 65 51
Germany*
(Langen)
Customer Technical Support . . . . . . . . . . . . . . . . . . . . . 06103 . . . . . . . . . . . . . . . 971-200
Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06103 . . . . . . . . . . . . . . . 971-500
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06103 . . . . . . . . . . . . . . . 971-666
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06103 . . . . . . . . . . . . . . . 971-460
Hong Kong
NOTE: Customers in
Hong Kong call
Malaysia for technical
assistance for Dell
Dimension systems
and for customer
assistance.
Technical Support
(Dell Dimension systems only) (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4948
Technical Support (Other systems) . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 96 4107
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 96 4109
Corporate Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 96 4108
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Customer Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-850-543-543
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-850-235-235
SalesFax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . . . 286 2020
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . . . 286 6848
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . . . 204 4761
TechFax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . . . 204 4044
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01 . . . . . . . . . . . . . . . . . 286 0500
Italy*
(Milan)
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264 21 820
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264 13 420
Japan
(Kawasaki)
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 0088-22-7890
Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 044 . . . . . . . . . . . . . . . . 556-4240
Direct Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 044 . . . . . . . . . . . . . . . . 556-3344
Commercial Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 044 . . . . . . . . . . . . . . . . 556-3430
556-3440
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 044 . . . . . . . . . . . . . . . . 556-4300
Korea
(Seoul)
NOTE: Customers in
Korea call Malaysia for
customer assistance.
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 080-200-3800
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 080-200-3600
Corporate Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 080-200-3900
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394 3122
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 5600
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Diagnostics and Troubleshooting Guide
Latin America
NOTE: Customers in
Latin America call the
U.S.A. for sales, customer,
and technical assistance.
Customer Technical Support (Austin, Texas, U.S.A.). . . . 512 . . . . . . . . . . . . . . . . 728-4093
Customer Service (Austin, Texas, U.S.A.) . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-3619
Fax (Technical Support and Customer Service)
(Austin, Texas, U.S.A.) . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-3883
Sales (Austin, Texas, U.S.A.) . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-4397
SalesFax (Austin, Texas, U.S.A.) . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-4600
728-3772
Luxembourg*
NOTE: Customers in
Luxembourg may call
Belgium for sales,
customer, and technical
assistance as well as the
SalesFax service, and they
call the Netherlands for
the TechFax and
TechConnect BBS
services.
Customer Technical Support (Brussels, Belgium) . . . . . . . . . . . . . . . . . .toll free: 0800 2109
Customer Service (Luxembourg). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .295151
Customer Service (Brussels, Belgium). . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . .481 92 99
SalesFax (Brussels, Belgium) . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . .481 92 44
TechFax (Amsterdam, Netherlands) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .682 91 06
TechConnect BBS (Amsterdam, Netherlands) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .686 65 04
Macau
NOTE: Customers in
Macau call Malaysia for
technical assistance for
Dell Dimension systems
and for customer assis-
tance.
Technical Support (Dell Dimension systems only) (Penang, Malaysia) . . . . . . . . . . . . 810 4948
Technical Support (Other systems) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0800 582
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0800 581
Malaysia
(Penang)
Technical Support (Dell Dimension systems only) . . . . . . 04 . . . . . . . . . . . . . . . . . 810 4946
Technical Support (Other systems) . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 1 800 888 298
Customer Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04 . . . . . . . . . . . . . . . . . 810 4949
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 1 800 888 202
Corporate Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 1 800 888 213
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
NOTE: Customers in
Mexico call the U.S.A. for
access to the Automated
Order-Status System and
AutoTech.
Automated Order-Status System
(Austin, Texas, U.S.A.) . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-0685
AutoTech (Automated technical support)
(Austin, Texas, U.S.A.) . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-0686
Customer Technical Support . . . . . . . . . . . . . . . . . . . . . 525 . . . . . . . . . . . . . . . . 228-7870
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 . . . . . . . . . . . . . . . . 228-7811
toll free: 91-800-900-37
toll free: 91-800-904-49
Customer Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 . . . . . . . . . . . . . . . . 228-7878
Main. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 . . . . . . . . . . . . . . . . 228-7800
Netherlands*
(Amsterdam)
Customer Technical Support . . . . . . . . . . . . . . . . . . . . . 020 . . . . . . . . . . . . . . . . .5818838
Direct Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0800-0663
Direct SalesFax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020 . . . . . . . . . . . . . . . . 682 7171
Corporate Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020 . . . . . . . . . . . . . . . . 581 8818
Corporate SalesFax . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020 . . . . . . . . . . . . . . . . 686 8003
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020 . . . . . . . . . . . . . . . . 686 6504
New Zealand
Technical Support
(Dell Dimension systems only) ($2.50 + GST per call). . . . . . . . . . . . . . . . . . . . . . . 0900 51010
Technical Support (Other systems) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0800 446 255
Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0800 444 617
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0800 441 567
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0800 441 566
Norway*
(Lysaker)
Customer Technical Support and Customer Service . . . . . . . . . . . . . . . . . . . . . 22-67 50 00
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67-125 711
Poland*
(Warsaw)
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620-7898
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620-4584
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Diagnostics and Troubleshooting Guide
Singapore
(Singapore)
NOTE: Customers in Sin-
gapore call Malaysia for
technical assistance for
Dell Dimension systems
and for customer assis-
tance.
Technical Support
(Dell Dimension systems only) (Penang, Malaysia) . . . . . . . 04 . . . . . . . . . . . . . . . . . 810 4947
Technical Support (Other systems) . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 6011 051
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . 04 . . . . . . . . . . . . . . . . . 810 4949
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 6011 054
Corporate Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 6011 053
South Africa
(Johannesburg)
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 011 . . . . . . . . . . . . . . . . 709 7700
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 011 . . . . . . . . . . . . . . . . 709 7710
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 011 . . . . . . . . . . . . . . . . 706 0495
Southeast Asian/
Pacific Countries
(excluding Australia,
Brunei, China, Hong
Kong, Japan, Korea,
Macau, Malaysia, New
Zealand, Singapore,
Taiwan, and Thailand—
see individual listings for
these countries)
Customer Technical Support, Customer Service,
and Sales (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 4 810-4810
Spain*
(Madrid)
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . .902 100 130
Customer Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . . .329 10 80
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . . .329 33 53
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . .902 100 185
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . . .722 92 00
Sweden*
(Upplands Vasby)
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08 . . . . . . . . . . . . . . . .590 05 199
Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08 . . . . . . . . . . . . . . . .590 05 169
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08 . . . . . . . . . . . . . . . .590 05 591
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08 . . . . . . . . . . . . . . . .590 05 185
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0844 811 411
Commercial Services . . . . . . . . . . . . . . . . . . . . . . . . . . 022 . . . . . . . . . . . . . . . .799 01 01
Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 022 . . . . . . . . . . . . . . . .799 01 50
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 022 . . . . . . . . . . . . . . . .799 01 90
Taiwan
NOTE: Customers in Tai-
wan call Malaysia for cus-
tomer assistance.
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0080 651 226/0800 33 557
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Transaction Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0080 651 228/0800 33 556
Corporate Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .toll free: 0080 651 227/0800 33 555
Thailand
NOTE: Customers in
Thailand call Malaysia for
customer assistance.
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 0880 060 07
Customer Service (Penang, Malaysia) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 4949
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 0880 060 06
U.K.*
(Bracknell)
Customer Technical Support
(Dell Dimension systems) . . . . . . . . . . . . . . . . . . . . . . . . . 01344 . . . . . . . . . . . . . . . .720111
Customer Technical Support (Other systems) . . . . . . . . . 01344 . . . . . . . . . . . . . . . .723723
Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01344 . . . . . . . . . . . . . . . .720110
TechFax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01344 . . . . . . . . . . . . . . . .723178
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01344 . . . . . . . . . . . . . . . .723858
Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01344 . . . . . . . . . . . . . . . .720000
*
For technical assistance in this country after normal working hours, use one of the following numbers:
(353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number
Diagnostics and Troubleshooting Guide
U.S.A.
(Austin, Texas)
Automated Order-Status System . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-433-9014
AutoTech (Automated technical support). . . . . . . . . . . . . . . . . . . . . toll free: 1-800-247-9362
Customer Technical Support (Desktops)
(Return Material Authorization Numbers—warranty repairs) . . . . . . . toll free: 1-800-624-9896
Customer Technical Support (Server Hotline)
(Return Material Authorization Numbers—warranty repairs) . . . . . . . toll free: 1-800-967-1068
Dell Customer Service
(Credit Return Authorization Numbers). . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-624-9897
Dell Sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-247-4618
DellWare® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-753-7201
DellWare FaxBack Service . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-1681
Fee-Based Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-433-9005
Sales (Catalogs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-426-5150
Spare Parts Sales:
Dell Direct1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-274-1490
Major Accounts2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-357-3355
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-727-8320
TechFax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-950-1329
TechConnect BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 728-8528
Switchboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 . . . . . . . . . . . . . . . . 338-4400
1 Use this telephone number if your call is about a system purchased for home, personal, or small-business use.
2 Use this number if you are calling for an established Dell national account (have your account number handy), if you work for a
governmental agency (local, state, or federal), or if you work for an educational or medical institution.
Table 7-3. Dell Contact Numbers (continued)
Country (City)
Area
Local Number or
Department Name or Service
Code
Toll-Free Number