Fortinet FortiManager-3000B Quick Start Manual

Text of the manual

© Copyright 2008 Fortinet Incorporated. All rights reserved.

Products mentioned in this document are trademarks or registered trademarks of their respective holders. Regulatory Compliance FCC Class B Part 15 CSA/CUS 28 March 2008 Visit these links for more information and documentation for your Fortinet product. Technical Documentation - http://docs.forticare.com Fortinet Knowledge Center - http://kc.forticare.com Fortinet Technical Support - http://support.fortinet.com • • • Connecting Tools and Documenation Straight-through and cross over Ethernet cables Power Cables 4 hot-swappable hard disks DB-9 Serial Cable Copyright 2008 Fortinet Incorporated. All rights reserved. Trademarks Products mentioned in this document are trademarks. FortiManager-3000B QuickStart Guide Welcome | Bienvenue | Willkommen | ?迎 | 歓迎 | Bienvenido | Benvenuto 1 2 PS RST HDD 1 (P0) HDD 3 (P2) HDD 2 (P1) HDD 4 (P3) DISK DRIVE LEGEND POWER ACTIVITY 1 2 PS RST HDD 1 (P0) HDD 3 (P2) EMPTY EMPTY HDD 2 (P1) HDD 4 (P3) DISK DRIVE LEGEND POWER ACTIVITY 1 2 PS RST HDD 1 (P0) HDD 3 (P2) EMPTY EMPTY HDD 2 (P1) HDD 4 (P3) DISK DRIVE LEGEND POWER ACTIVITY Power connections USB for future use DB9 Serial connection Ethernet connections Ethernet connections LED Indicators USB (Behind front panel) Power Button Hardware Reset Button Front Back Power Suppy Alarm Reset Button ® Power connections Straight-through Ethernet cable connects to hub or switch on the network. Null modem cable connects to serial port on management computer. Package Contents Connector Type Speed Protocol Description Port 1 to 4 RJ-45 100/1000 Base-T Ethernet Connection to the internal network. CONSOLE DB9 9600 bps 8/N/1 RS-232 serial Optional connection to the management computer. Provides access to the command line interface. USB USB USB For future use. Connect the following to the FortiManager system. Ensure the FortiManager system is placed on a stable surface or securely mounted in a 19” rack. Insert the hard disks included in the FortiManager package into the bays of the FortiManager unit, starting in bay 1. Use the diagram on the front panel as a guide. Insert a network cable to port 1. Insert the other end to the router or switch connected to the network. Connect one power chord to a power supply. Connect the other power cord to an alternate power source if available. Connect the Power Cord to a surge protected power bar or power supply. Press the Power button to turn on the FortiManager unit. The power LED appears blue and the hard disk icon LED flashes blue while the system boots. For more information, see the FortiManager Install Guide. • • • • • • • • FortiManager-3000B 02-30006-462-20080328 QuickStart Guide Web-based manager The FortiManager web-based manager is an easy to use management tool. Use it to configure the administrator password, the interface and default gateway addresses, and the DNS server addresses. Requirements: An Ethernet connection between the FortiManager system and management computer. A web browser such as FireFox 2.0 and higher or Internet Explorer 6.0 and higher on the management computer. • • Command Line Interface (CLI) The CLI is a full-featured management tool. Use it to configure the administrator password, the interface addresses, the default gateway address, and the DNS server addresses. To configure advanced settings, see the Tools and Documentation CD-ROM. Requirements: The DB9 serial connection between the FortiManager system and management com- puter. A terminal emulation application (HyperTerminal for Windows) on the management computer. • • Configuration Tools Light Icon Description The light flashes orange when packets are sent and received on the Ethernet port 1 and 2. Power indicator is blue when the FortiManager system is on. The light flashes blue when reading the boot device. Hard Disk Upper LED Blue when the hard disk is properly inserted into the drive bay and the FortiManager is plugged in to a power source. Hard Disk Lower LED Flashes blue when reading and writing to the hard disk.

Port 1 Interface:

IP: ____.____.____.____ Netmask: ____.____.____.____ Port 2 Interface: IP: ____.____.____.____ Netmask: ____.____.____.____ Port 3 Interface: IP: ____.____.____.____ Netmask: ____.____.____.____ Port 4 interface: IP: ____.____.____.____ Netmask: ____.____.____.____ The interface IP address and netmask must be valid for the internal network. General settings Administrator password: Network Settings: Default Gateway: ____.____.____.____ Primary DNS Server: ____.____.____.____ Secondary DNS Server: ____.____.____.____ Factory default settings Port 1 interface 192.168.1.99 Administrative account settings Port 2 interface 0.0.0.0 User name admin Port 3 interface 0.0.0.0 Password (none) Port 4 interface 0.0.0.0 Web-based Manager Connect the FortiManager system interface to a management computer Ethernet interface. Use a cross-over Ethernet cable to connect the devices directly. Use straight- through Ethernet cables to connect the devices through a hub or switch. Configure the management computer to be on the same subnet as the internal interface of the FortiManager system. To do this, change the IP address of the management computer to 192.168.1.2 and the netmask to 255.255.255.0. To access the FortiManager system web-based manager, start Internet Explorer and browse to https://192.168.1.99 (remember to include the “s” in https://). Type admin in the Name field and select Login (no password required). Changing an Administrator Password To change the administrator password In System Settings, go to Administration > Administrators. Select Edit. Select Change Password. Enter and confirm the password. Select OK. Configuring the IP Address and Netmask To configure the IP address In System Settings, go to Network > Interface. Select Edit. Enter the IP address and netmask. Select OK. Configuring the Default Gateway To configure the default gateway In System Settings, go to Network > Routing Table. Enter the gateway IP address and netmask. Enter the Destination IP and select the Interface. Select OK. Adding a FortiGate unit Before you can manage a FortiGate unit, you must add it to the Device Manager. Adding an existing operational device will not result in an immediate connection to the device. Device connection only happens when you successfully resync the device. To add a FortiGate device In Device Manager, got to Device > Add Device from the main toolbar. Enter the following information and select Discover. IP Address Enter the IP Address of the device to add. Discover via Select a method used to find the device. Currently, only CLI (via SSH) is supported. By using the CLI (via SSH) Method, Device Manager is able to record each device being added. Admin user Select Default (admin) if the device uses the default “admin” as its admin user. Select Other and enter the admin user name if the device uses a different user name other than the default “admin”. Password Enter the password for the admin user. The discovery process starts. When it completes, the Add New Device page appears. Verify the information and add a Description if desired. Select Add. 1. 2. 3. 4. 1. 2. 3. 4. 5. 1. 2. 3. 4. 1. 2. 3. 4. 1. 2. 3. 4. Command Line Interface Use the DB-9 serial cable to connect the FortiManager System Console port to the management computer serial port. Start a terminal emulation program (HyperTerminal) on the management computer. Use these settings: Baud Rate (bps) 9600, Data bits 8, Parity None, Stop bits 1, and Flow Control None. At the Login: prompt, type admin and press Enter twice (no password required). Changing an Administrator Password To change the administrator password, enter the following commands config fmsystem admin user edit admin set password end Configuring the IP Address and Netmask To configure the IP address and netmask, enter the following commands config fmsystem interface edit port1 set ip / end Configuring the Default Gateway To configure the default gateway, enter the following commands config fmsystem route edit set device {port1 | port2} set dst / set gateway end 1. 2. 3. 4. Collecting Information Configuring You have finished configuring the basic settings. You are now ready to add and manage FortiGate units. You can also add FortiClient installations and manager firmware updates and IPS updates as well as many more management configurations and options. To explore the full range of configuration options, see the online help or the Tools and Documentation CD. Configure the FortiGate unit to be managed through a FortiManager server. Communica- tion between the FortiGate unit and the FortiManager server is via an IPSec VPN that is invisibly pre-configured on the FortiGate unit. To configure the FortiGate unit Log in to the FortiGate unit. Go to System > Admin > FortiManager. Complete the configuration and select OK. 1. 2. 3.

Other Security System Manuals