Foxcom 7870 Installation And User Manual
Read Online
Read the Foxcom 7870 Installation And User Manual online using the built-in PDF viewer.
Text of the manual
This manual contains propriety and confidential information of Foxcom Reproduction,
release to any third party, or any other unauthorized use, of any information contained
herein is expressly forbidden.
The information contained in this document is believed to be accurate as of the time of
going to press. Specifications are subject to change without notice.
Corporate Office Israel
Beck Science Center
8 Hartom Street, Har Hotzvim
P.O.Box 45092
Jerusalem 91450
Tel: +972-2-589-9888
Fax: +972-2-589-9898
US Office
Princeton Forrestal Village
136 Main Street Suite 300
Princeton, NJ 08540
Tel: 609-514-1800
Toll free: 1-866-ONEPATH
Fax: 609-514-1881
South Africa Office
Block 4, Kingfisher Office Park 228
Siphosethu Rd.
Mt. Edgecombe
Durban, KwaZulu Natal
Tel. +278 7.751.3911
Fax +278.6.501.6624
Website: www.foxcom.com
e-mail: [email protected]
7870 Interfacility Link Installation and User’s Guide
page i
Foxcom proprietary information
Table of Contents
Important Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Chapter 1 Introduction to the 7870 Interfacility Link ..................................... 1
1.1
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.2
Product Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.3
Panel Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.4
Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Chapter 2 Installation........................................................................................ 7
2.1
Setting up the Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.2
Connecting the Fiber Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.3
Setting Up the Receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2.4
Powering the IFL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2.4.1
7180M Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5
Connecting the Back Panel Jumpers. . . . . . . . . . . . . . . . . . . . . . . . . .13
2.6
Aligning the Fiber Optic Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Chapter 3 Product Specifications.................................................................. 17
3.1
7870 Interfacility Link Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .17
3.2
Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3.3
7870 Interfacility Link Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
3.3.1
Transmitter Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.3.2
Receiver Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4
7180M Chassis Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
3.4.1
7180M Alarm Connector Pinouts [J12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4.2
7180M Monitor Connector Pinout [J13]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.4.3
7180M and Redundancy Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Chapter 4 Troubleshooting ............................................................................ 25
Appendix 1 Cleaning Fiber Optic Connections ........................................... 27
Appendix 1.1 Cleaning Procedures for FC/APC Connectors ..................... 28
Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports................. 29
Appendix 1.2.1 Swab Method .........................................................................................29
Appendix 1.2.2 Compressed Air Method .......................................................................29
Appendix 2 Installing a Standalone Unit...................................................... 31
Appendix 3 The 2380 Relay Adapter ............................................................ 33
Appendix 3.1 Installing the 2380 Relay Adapter.......................................... 34
Appendix 3.1.1 Parts Required for Installing the 2380 ...................................................34
Appendix 3.1.2 Mounting the the 2380 Relay Adapter ...................................................34
Appendix 3.2 2380 Dimensions and Front Panel Label .............................. 36
Appendix 3.3 2380 Adapter Pinouts.............................................................. 37
Appendix 4 Pinout Charts and Diagrams..................................................... 39
Document no. 93-005-35-C5
Figures
Figure 1
Option Label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Figure 2
7870T Transmitter Front and Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 3
7870R Receiver Front and Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 4
7870Transmitter Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 5
7870R Receiver Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 6
Typical Application of a 7870 Interfacility Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 7
7180M Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 8
Jumper Installation: Tx and Rx only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 9
Jumper Installation: 2040 Switch in slot 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 10
Jumper Installation: 2040 Switch in slot 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 11
Jumper Installation: 2040 Switch in slots 2 and 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 12
Fiber Optic Alignment Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 13
Unit dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 14
7810M Chassis Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 15
7870T Transmitter pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 16
7870R Receiver pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 17
7180M Chassis rear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 18
7180M Chassis Pin numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 19
Wiping the connector with a Kim wiper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 20
Wiping the connector with a Kim wiper [2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 21
Cleaning the Optical Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 22
Cleaning the Optical Port [2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 23
Installing the guide pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 24
Mounting the adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 25
Mounting the Screws [1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 26
Mounting the screws [2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 27
Mounted 2380 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 28
2380 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 29
2380 Front Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 30
2380 Pin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 31
Standard 7180M and 7180M with 2380 Relay Adapter Pinout . . . . . . . . . . . . . . . . . . 40
Figure 32
7180M and 2040 RF Switch Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 33
Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5. . . . . . . . . . . . . . . . . . 42
Figure 34
Pinout of 7180M jumper with 2040 RF switch in slot 5 . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 35
Pinout of 7180M jumper with 2040 RF switch in slot 5 . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 36
Pinout of 7180 jumper with transmitter and receiver units only . . . . . . . . . . . . . . . . . . 45
Tables
Table 1 7870T Transmitter LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 2 7870R Receiver LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 3 7870 Interfacility Link Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 4 7870T Transmitter Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 5 7870R Receiver Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 6 7180M Alarm Connector [J12] Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 7 7180M Monitor Connector [J13] Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 8 Troubleshooting the Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 9 Troubleshooting the Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 10 Cleaning materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 11 2380 Alarms Pinouts [J2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 12 7180M Monitor Connector [J4] Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7870 Interfacility Link Installation and User’s Guide
page iii
Foxcom proprietary information
Important Information
Warranty and Repair Policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
General Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Specific Product Warranty Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Returns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Limitations of Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Reporting Defects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Personal Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Equipment Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Warranty and Repair Policy
Foxcom performs testing and inspection to verify the quality and
reliability of our products. Foxcom uses every reasonable precaution
to ensure that each unit meets specifications before shipment.
Customers are asked to advise their incoming inspection, assembly,
and test personnel as to the precautions required in handling and
testing our products. Many of these precautions are to be found in
this manual.
The products are covered by the following warranties:
General Warranty
Foxcom warrants to the original purchaser all standard products sold
by Foxcom to be free of defects in material and workmanship for 24
months from date of shipment from Foxcom. During the warranty
period, Foxcom will repair or replace any product that Foxcom proves
to be defective. This warranty does not apply to any product which
has been subject to alteration, abuse, improper installation or
application, accident, electrical or environmental over-stress,
negligence in use, storage, transportation or handling.
Specific Product Warranty Instructions
All Foxcom products are warranted against defects in workmanship,
materials and construction, and to no further extent. Any claim for
repair or replacement of units found to be defective on incoming
inspection by a customer must be made within 30 days of receipt of
shipment, or within 30 days of discovery of a defect within the
warranty period.
This warranty is the only warranty made by Foxcom and is in lieu of
all other warranties, expressed or implied. Foxcom sales agents or
representatives are not authorized to make commitments on
warranty returns.
Document no. 93-005-35-C5
Returns
In the event that it is necessary to return any product against above
warranty, the following procedure shall be followed:
1. Return authorization is to be received from Foxcom prior to
returning any unit. Advise Foxcom of the model, serial number,
and discrepancy. The unit may then be forwarded to Foxcom,
transportation prepaid. Devices returned collect or without
authorization may not be accepted.
2. Prior to repair, Foxcom will advise the customer of our test
results and any charges for repairing customer-caused problems
or out-of-warranty conditions etc.
3. Repaired products are warranted for the balance of the original
warranty period, or at least 90 days from date of shipment.
Limitations of Liabilities
Foxcom's liability on any claim, of any kind, including negligence for
any loss or damage arising from, connected with, or resulting from
the purchase order, contract, quotation, or from the performance or
breach thereof, or from the design, manufacture, sale, delivery,
installation, inspection, operation or use of any equipment covered by
or furnished under this contact, shall in no case exceed the purchase
price of the device which gives rise to the claim.
EXCEPT AS EXPRESSLY PROVIDED HEREIN, FOXCOM MAKES NO
WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY GOODS,
PARTS AND SERVICES PROVIDED IN CONNECTION WITH THIS AGREEMENT
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. FOXCOM
SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT NOT
LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING
OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND
SERVICE HEREUNDER, OR THE PERFORMANCE, USE OF, OR INABILITY TO
USE THE GOODS, PARTS AND SERVICE.
The Company's exclusive warranty and the remedy provided for
breach thereof shall not apply to:
1. Any Product used or operated other than pursuant to the
Company's written instructions,
2. Damage or deficiencies resulting from accident, alteration,
modification, misuse, tampering, negligence, improper
maintenance, installation or abuse,
3. Use of any Product other than at the Installation Site,
4. Use of any Product that is defective or damaged due to misuse,
accident, or neglect, or due to external electrical stress, lightning
or other acts of nature,
5. Use of any Product by a person who is not any authorized
employee of the Customer, or
6. Used other than as explicitly authorized in writing by the
Company.
7870 Interfacility Link Installation and User’s Guide
page v
Foxcom proprietary information
Reporting Defects
The units were inspected before shipment and found to be free of
mechanical and electrical defects.
Examine the units for any damage which may have been caused in
transit. If damage is discovered, file a claim with the freight carrier
immediately. Notify Foxcom as soon as possible.
Note Keep all packing material until you have completed the
inspection.
Precautions
Personal Safety
OPTICAL RADIATION
Applying power to the transmitter unit will create a laser energy
source operating in Class I as defined by IEC 825-1. Use either an
infrared viewer, optical power meter or fluorescent screen for optical
output verification.
AC POWER HAZARD
The rackmount power supply line is EMI filtered. The chassis is
connected to earth ground in compliance with safety requirements.
Always use the 3-prong AC plug with earth ground to avoid
possibility of electrical shock hazard to personnel.
Equipment Safety
To avoid damaging your product, please observe the following:
1. The output of the receiver is AC coupled and can withstand the
bias from a satellite receiver. Do not exceed 25V DC bias.
2. The input of the transmitter has an optional built-in bias for
inserting DC power up the coax to the LNB. Make certain that
any equipment or test equipment connected to the transmitter
input can withstand this bias.
3. Do not allow any dirt or foreign material to get into the optical
connector bulkheads. This may cause damage to the polished
optical connector end faces.
4. The optical fiber jumper cable bend radius is 3 cm. Smaller radii
can cause excessive optical loss and/or fiber breakage.
5. If multiple transmitters are installed in the chassis allow
sufficient room for adequate ventilation; otherwise the units may
overheat causing possible safety hazard or equipment damage.
6.
Fuses: The 7180M chassis does not have fuses. If the unit fails, pull
the power supply out from the chassis and then push it back in.
7. When several units are installed on one 7180M chassis, ensure
that the total units’ current consumption (including any LNB
bias) does not exceed 6A.
7870 Interfacility Link Installation and User’s Guide
page 1
Foxcom proprietary information
1
Introduction to the 7870 Interfacility Link
1.1
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2
Product Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3
Panel Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.4
Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
The 7870 IFL is a 10 – 200 MHz IF fiber optic link used primarily in
short distance, single channel video applications with high input/
output power levels. The 7870 IFL consists of an optical transmitter
(7870T) which receives signals from satellite modems, video
modulators, or exciters and transmits them to an optical receiver
(7870R) via singlemode fiber.
The 7870T and 7870R modules plug into a 7180M, a 3U chassis and
power supply, which enables expansion of the system to
accommodate up to eight Sat-Light™ modules. Accessories include
the Model 7001P Power Supply, the Model 2040 1:1 Redundant
Switch, the Model 2100 Amplifier, and the Model 7050 Serial Optical
Multiplexer, an asynchronous data transceiver.
The 7870 IFL transmits all satellite modulation schemes - digital or
analog. Any FM modulated RF signal is transmitted accurately. The
RF signal is directly modulated and adds virtually no phase noise to
the original signal. The direct modulation, along with extremely flat
amplitude and group delay, guarantees low bit error rate (BER) and
high signal quality, independent of distance.
LEDs, and back panel monitors, and alarms allow for complete
system status monitoring and for interfacing with monitor and
control (M&C) systems. Gain Control at the Receiver sets the RF
level.
Document no. 93-005-35-C5
1.1
Options
The 7870 Interfacility Link comes with a variety of options:
1. 50 Ω Input/Output Impedance/BNC female connector; Standard
impedance is 75 Ω/BNC, female connectors.
2. Standalone unit; The 7870 IFL can be installed as a standalone
unit. If the 7870 is used as a standalone, a separate power supply
must be used.
On the side of the 7870T and the 7870R units is a label1 which lists
the options. Under each option is a square. If the unit includes a
particular option the square under the option should be marked.
Figure 1
Option Label
1.
The sticker includes options which are not relevant to the 7870 IFL.
1.2 Product Drawings
7870 Interfacility Link Installation and User’s Guide
page 3
Foxcom proprietary information
1.2
Product Drawings
Figure 2
7870T Transmitter Front and Rear Panel
Figure 3
7870R Receiver Front and Rear Panel
1.3 Panel Descriptions
page 4
Document no. 93-005-35-C5
1.3
Panel Descriptions
On the Front Panel of the 7870 IFL units are two LEDs. Both LEDs
should be on when the unit is in use. T
The LEDs on the Front Panel of the 7870 Transmitter and Receiver
are:
LED Name
LED Function
Laser
Indicates if the laser is functioning
RF
Indicates RF signal level
•
Green: Input level is within 3 dB of specification (level is -2 to -28
dBm)
•
Amber: Input level exceeds maximum recommended level by 3
dB or more (level is >-2 dBm)
•
Off: Input level is below minimum recommended level by 3 dB or
more (level is < -28 dBm
Table 1 7870T Transmitter LEDs
LED Name
LED Function
Opt.
Indicates if the optical input power is above the minimal level [≥3 dBm]
RF
Indicates RF signal level
•
Green: Input level is within 3 dB of specification (level is -2 to -28
dBm)
•
Amber: Input level exceeds maximum recommended level by 3 dB
or more (level is >-2 dBm)
•
Off: Input level is below minimum recommended level by 3 dB or
more (level is < -28 dBm
Table 2 7870R Receiver LEDs
1.4 Block Diagrams
7870 Interfacility Link Installation and User’s Guide
page 5
Foxcom proprietary information
1.4
Block Diagrams
Figure 4
7870Transmitter Block Diagram
Figure 5
7870R Receiver Block Diagram
7870 Interfacility Link Installation and User’s Guide
page 7
Foxcom proprietary information
2
Installation
Chapter 2 describes how to install the 7870 Interfacility Link units.
Setting up the 7870E Transmitter/Receiver consists of:
2.1
Setting up the Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2
Connecting the Fiber Optic Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3
Setting Up the Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.4
Powering the IFL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.4.1
7180M Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5
Connecting the Back Panel Jumpers . . . . . . . . . . . . . . . . . . . . . . . 13
2.6
Aligning the Fiber Optic Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Observe all warnings and cautions mentioned at the beginning of
this manual (See Important Information on page iii).
If after set-up you experience problems, see Chapter 4 Troubleshooting
on page 25.
Figure 6
Typical Application of a 7870 Interfacility Link
2.1 Setting up the Transmitter
page 8
Document no. 93-005-35-C5
2.1
Setting up the Transmitter
1. Place the 7870T in the 7180M Chassis.
2. Apply AC power to the chassis. The Power Supply and Laser
LEDs should be lit.
3. Using an optical power meter, measure the optical power. Insert
the meter’s cable into the Transmitter’s optical connector. Power
levels should be 0.5 mW minimum (-3 dBm).
Alternatively, use a DVM to measure the voltage at:
• 7180M Rackmount: Pins J13-P17 through J13-P24 for the slot
being measured (See Table 4 7870T Transmitter Pinout on page 20
for details regarding J13 pinouts). [7180M Rackmount]
• Standalone: At pin #6 of the 9 pin connector [Standalone]
The signal level should be -4.5 ± -0.3VDC.
4. On the rear panel, connect the coax cable to the RF Input
Connector. The RF LED should be lit.
5. On the rear panel, connect the fiber optic cable to the Optical
Connector.
Note If either LED is not lit, see Chapter 4 Troubleshooting on page 25.
Caution
When monitoring the voltage outputs use only a high
resistance DVM.
2.2 Connecting the Fiber Optic Cable
7870 Interfacility Link Installation and User’s Guide
page 9
Foxcom proprietary information
2.2
Connecting the Fiber Optic Cable
Before connecting the cable:
1. The fiber optic cable must be either fusion spliced or connected via
FC/APC connectors.
2. Wipe the connector with a lint-free cotton cloth.
3. Note the polarity key of the optical connector before inserting.
To connect the cable:
1. Line Up the Polarity Key.
2. Insert the connector
3. Tighten the connector
Caution
Do not apply any glue, silicon adhesive, or any other
material to the fiber optic connector!
2.3 Setting Up the Receiver
page 10
Document no. 93-005-35-C5
2.3
Setting Up the Receiver
1. Place the 7870R Receiver in any of the 7180M Chassis, unless a
2040 RF Switch is installed. (See Figure 7
7180M Chassis Rear View
on page 12.)
Note If a 2040 RF Switch(es) is being installed, then slots 2 and/or 5
of the 7180M are reserved for the switch(es).
2. Apply AC power to the chassis. The Power Supply’s LED should
be lit.
3. Using an optical power meter, measure the optical power coming
to the Receiver from the fiber optic cable. The power levels of the
Receiver should be the power level measured at the Transmitter
minus the fiber loss2.
Alternatively, use a DVM to measure the voltage at:
• pins J13-P9 through J13-P16 for the slot being measured (See
Table 5 7870R Receiver Pinout on page 21 for details regarding J13
pinouts) (7180M Rackmount). The voltage level should be 1 V
for each 1 mW measured at the Receiver input.
• at pin #5 of the 9 pin connector (standalone)
4. On the rear panel, connect the coax cable to the RF Output
Connector.
5. Adjust the Gain Control Potentiometer to give the desired output
power. Using a small screw driver, turn the potentiometer
(located on the front panel) to increase or decrease the gain.
Notes
1. The potentiometer is 10 turn potentiometer.
• To increase the gain, turn the gain control clockwise.
• To decrease the gain, turn the gain control counterclockwise.
For more information see 2.6 Aligning the Fiber Optic Link on page15.
2. If the LED is not lit, see Chapter 4 Troubleshooting on page 25.
2.
Fiber loss is defined as:
(attenuation/km x length (km) of the fiber optic cable) + (0.5 dB ×
number of connectors).
For example if a signal with an optical wavelength of 1310 nm is
transmitted over a link 10 kilometers long which had two connectors
the loss would be:
(0.4 dB/km × 10 km) + (0.5 dB × 2) = 5.0 dB
2.4 Powering the IFL
7870 Interfacility Link Installation and User’s Guide
page 11
Foxcom proprietary information
2.4
Powering the IFL
•
Transmitter power requirement: +14 VDC @ 200 mA
•
Receiver power requirement: +14 VDC @ 250 mA.
•
The Standalone Transmitter/Receiver is powered by a Foxcom
supplied external DC power supply.
•
The Rackmount Transmitters/Receivers are plugged into the
rackmount chassis. The chassis can accept and power up to eight
units.
Note At temperatures below10°C, the Transmitter’s internal heater
will require an additional 100 mA. The Transmitter’s total
power requirement will then be 300 mA.
Caution
Ensure that there is a good airflow around the chassis
rackmount.
2.4 Powering the IFL
7870 Interfacility Link Installation and User’s Guide
page 12
Foxcom proprietary information
2.4.1
7180M Chassis
The 7180M Chassis provides power to the plug in units. The power supply is a switching type. Each plug-in
regulates its own voltage. The power supply provides:
•
14 VDC stable
•
AC input; 100 - 240 VAC
•
Units can be plugged in “hot standby”
Figure 7
7180M Chassis Rear View
2.5 Connecting the Back Panel Jumpers
7870 Interfacility Link Installation and User’s Guide
page 13
Foxcom proprietary information
2.5
Connecting the Back Panel Jumpers
On the rear panel of the 7180M Back Panel are product selectors (JP1 to JP4). The 3 pin selectors (male) are the
connecting point between the slots and the back panel. One pin is for the transmitter/receiver (Tx/Rx), one is for the
optional 2040 1:1 Redundant Switch, and one is for the 7180M. A 2 pin jumper (female) is placed on the relevant pins to
complete the connection between the 7180M and the units. For example, if a 2040 Switch is being used, the jumper is
placed on the Switch-7180M pins.
To connect the jumpers:
1. Each jumper has two sets of pins, upper and lower. The upper pins are labeled SW (Switch) and the lower pins Tx/Rx.
2. If the 7180M has Tx or Rx units only, place all jumpers on the lower two pins.
Figure 8
Jumper Installation: Tx and Rx only
3. If the 2040 Switch is installed in Slot 2, place the JP1 and JP2 jumpers on the higher two pins and the JP3 and JP4
jumpers on the lower two pins.
Figure 9
Jumper Installation: 2040 Switch in slot 2
2.5 Connecting the Back Panel Jumpers
7870 Interfacility Link Installation and User’s Guide
page 14
Foxcom proprietary information
4. If the 2040 Switch is installed in Slot 5, place the JP1 and JP2 jumpers on the lower two pins and the JP3 and JP4
jumpers on the higher two pins.
Figure 10 Jumper Installation: 2040 Switch in slot 5
5. If the 2040 Switch is installed in Slots 2 and 5, place the JP1, JP2, JP3, and JP4 jumpers on the higher two pins.
Figure 11 Jumper Installation: 2040 Switch in slots 2 and 5
2.6 Aligning the Fiber Optic Link
7870 Interfacility Link Installation and User’s Guide
page 15
Foxcom proprietary information
2.6
Aligning the Fiber Optic Link
The final step in installing the 7870 Interfacility Link is
re-adjusting the Receiver Gain Control for unity gain.
To set the unity gain (standard version)
1. Set the Signal Generator to -15 dBm. Alternatively measure the
operational input level.
2. Set up the system as shown in Figure 12 Fiber Optic Alignment Setup
3. Adjust the Receiver Gain Control for -15 dBm reading on the
power meter.
Figure 12 Fiber Optic Alignment Setup
3.1 7870 Interfacility Link Specifications
7870 Interfacility Link Installation and User’s Guide
page 17
Foxcom proprietary information
3
Product Specifications
3.1
7870 Interfacility Link Specifications . . . . . . . . . . . . . . . . . . . . . . . 17
3.2
Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.3
7870 Interfacility Link Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.3.1
Transmitter Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.3.2
Receiver Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4
7180M Chassis Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.4.1
7180M Alarm Connector Pinouts [J12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4.2
7180M Monitor Connector Pinout [J13]. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.4.3
7180M and Redundancy Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.1
7870 Interfacility Link Specifications
RF Specifications
Frequency range
10 - 200 MHz
Flatness 10 – 200 MHz @ unity gain
± 0.4 dB [typical]
Flatness @ 36 MHz
± 0.2 dB [max.]
CNR
45 dB @ 36 MHz
Noise Figure [50 Ω]
@ unity gain / 1 dB optical loss
@ unity gain / 8 dB optical loss1
28 dB [typical]
35 dB [typica]
Noise Figure [75 Ω]
@ unity gain / 1 dB optical loss
@ unity gain / 8 dB optical loss1.
30 dB [typical]
37 dB [typica]
OIP3 @ -10 dBm in / 0 dBm out
24 dBm
Group delay variation @ 20 - 200 MHz
<1 nSec
Input /output impedance
75 Ω [50 Ω optional]
Third order modulation
- 50 dBc with 2 equal carrier, total input
power -5 dBm
Input signal range [total power]
-25 to - 5 dBm
Output signal range [total power]
-25 to - 5 dBm
Maximum input without damage
+10 dBm
Receiver gain control
Manual
RF connector
BNC female [default]
F, and SMA [optional]
Test port coupling
20 dBc
Table 3 7870 Interfacility Link Specifications
1.
@ 10 dB Link Gain
3.1 7870 Interfacility Link Specifications
page 18
Document no. 93-005-35-C5
Note If the link is between 100 - 500 meters, foxcom technicians will
limit the output power to +2 dBm/1.6 mW. This information
must be given to Foxcom when ordering the link.
Optical Specifications
Optical Wavelength
1310 ± 10 nm
Optical power output
0.5 mW/-2 dBm [minimum]
Optical connector
FC/APC
Optical budget / distance
16 dB / 40 Km
Optical return loss
-60 dB
Optical connector loss
0.5 dB/mated pair
Physical Specifications
Chassis capacity
8 plug-ins, and 2 power supplies
Chassis size
19” × 3U × 7”
Power for rackmount [max.]
100 to 240 VAC 50/60Hz 90 Watts
Standalone size
5” × 4.8” × 1.3”
Power for standalone
Transmitter
+14 VDC @ 200 mA max.
[300 mA temp.< 10° C)
Receiver
+14VDC @ 250 mA max.
Operating Temperature Range
-10°C to +55°C
Storage Temperature Range
-40°C to +85°C
All specifications are subject to change without prior notice
3.2 Model Dimensions
7870 Interfacility Link Installation and User’s Guide
page 19
Foxcom proprietary information
3.2
Model Dimensions
Figure 13
Unit dimensions
Figure 14
7810M Chassis Dimensions
3.3 7870 Interfacility Link Pinouts
page 20
Document no. 93-005-35-C5
3.3
7870 Interfacility Link Pinouts
3.3.1
Transmitter Pinout
Note If a 2380 Relay Adapter is installed RF and Optical Levels are measured
together; the alarm indicates a problem in either the RF or Optical Levels.
Figure 15
7870T Transmitter pinout
Standalone
9-Pin
Connector
[J13]
7180M
Chassis
Backplane
Connector
2380 Relay
Adapter
Connector
Name
Description
1
—
—
+14V Power
200 mA [max ≥ 10°C]1
2
—
—
Spare
Not Used
3
J11-P9, J12-P25
J13-P25
J4-P25
GND
Chassis Ground
4
J13-P1 to J13-P8
J4-P1 to J4-P8
RSSI
RF signal strength indicator:
range 0.2 - 10 V
5
J13-P9 to
J13-P16
J4-P9 to J4-P16
PDI
Indicates laser optical power:
range -4.2 to 4.8
6
J13-P17 to
J13-P24
J4-P17 to J4-P24
LSRI
Indicates Laser Bias;
Range
7
J12-P1 to J12-P8
J2: P1-P2
P3-P4, P5-P6
P7-P8, P9-P10
P11-P12, P13-
P14
P15-P16
RFA
RF Alarm: Open collector
interface.2 Sinks current when
RF level is low, up to 30 mA.
8
J12-P9 to
J12-P16
See note below
OPTA
Optical Alarm: Open Collector
Interface2.. Sinks current at low
optical, up to 30 mA.
9
J11-P1 to J11-P6
Spare
Not used
Table 4 7870T Transmitter Pinout
1.
300 ma below 10°C
2.
If the 2380 Relay Adapter is installed, the alarms are dry contact. See Appendix 3 The 2380
Relay Adapter on page 33.
3.3 7870 Interfacility Link Pinouts
7870 Interfacility Link Installation and User’s Guide
page 21
Foxcom proprietary information
3.3.2
Receiver Pinouts
Note If a 2380 Relay Adapter is installed RF and Optical Levels are measured
together; the alarm indicates a problem in either the RF or optical levels.
Figure 16
7870R Receiver pinout
Caution
When monitoring the voltage outputs use only a high resistance DVM.
Standalone
9 Pin
Connector
[J14]
7180M Chassis
Backplane
Connector
2380 Relay
Adapter
Connector
Name
Description
1
—
—
+14V Power 350 mA
2
—
—
Spare
Not Used
3
J11-P9
J12-P25
J13-P25
J4-P25
GND
Chassis Ground
4
J13-P1 to J13-P8
J4-P1 to J4-P8
RSSI
RF signal strength
indicator:
range 0.2 - 10 V
5
J13-P9 to J13-P16
J4-P9 to J4-P16
PDI
Indicates input optical
power: 1 V/ 1 m optical
power
6
—
—
Spare
Not used
7
J12-P1 to J12-P8
J2: P1-P2
P3-P4, P5-P6
P7-P8, P9-P10
P11-P12
P13-P14
P15-P16
RFA
RF Alarm: Open collector
interface.1 Sinks current
when RF level is low, up
to 30 mA.
8
J12-P9 to J12-P16
See note below
OPTA
Optical Alarm: Open
Collector Interface1..
Sinks current at low
optical, up to 30 mA.
9
—
—
Spare
Not used
Table 5 7870R Receiver Pinout
1.
If the 2380 Relay Adapter is installed, the alarms are dry contact. See Appendix 3 The
2380 Relay Adapter on page 33.
3.4 7180M Chassis Pinouts
7870 Interfacility Link Installation and User’s Guide
page 22
Foxcom proprietary information
3.4
7180M Chassis Pinouts
The unit’s pins are found at the backplane of the 7180M chassis. The 7180M chassis backplane incorporates eight slots.
Pinouts from the 9-pin connector at each slot are sent through the backplane assembly to the two 25-pin D-connectors,
J12 and J13, and one 9-pin connector, J113. Any monitor voltages to be measured may be done between the chassis
ground and the required pin.
For more information about pinouts, see Appendix 4 Pinout Charts and Diagrams on page 41.
Figure 17
7180M Chassis rear view
Figure 18 7180M Chassis Pin numbers
3.
In the 7870 the J11 connector is inoperative.
3.4 7180M Chassis Pinouts
7870 Interfacility Link Installation and User’s Guide
page 23
Foxcom proprietary information
3.4.1
7180M Alarm Connector Pinouts [J12]
Pin No.
Function
Name
Slot No.
1
RF Alarm
RfAlm1
1
2
RF Alarm
RfAlm2
2
3
RF Alarm
RfAlm3
3
4
RF Alarm
RfAlm4
4
5
RF Alarm
RfAlm5
5
6
RF Alarm
RfAlm6
6
7
RF Alarm
RfAlm7
7
8
RF Alarm
RfAlm8
8
9
Optical Alarm
OptAlm1
1
10
Optical Alarm
OptAlm2
2
11
Optical Alarm
OptAlm3
3
12
Optical Alarm
OptAlm4
4
13
Optical Alarm
OptAlm5
5
14
Optical Alarm
OptAlm6
6
15
Optical Alarm
OptAlm7
7
16
Optical Alarm
OptAlm8
8
17
18
19
20
21
Standby Power Supply
SPSNOP
22
Standby Power Supply
SPSCOM
23
Main Power Supply
MPSNOP
24
Main Power Supply
MPSCOM
25
Chassis Ground
GND
Table 6 7180M Alarm Connector [J12] Pinouts
3.4 7180M Chassis Pinouts
page 24
Document no. 93-005-35-C5
3.4.2
7180M Monitor Connector Pinout [J13]
3.4.3
7180M and Redundancy Switching
The 2040 Switch provides optional 1:1 redundancy switching for all
Foxcom Interfacility Links. If the customer chooses to add
redundancy switching to the link, the pin connector jumpers need to
be moved.
Detailed instructions on moving the jumpers are provided in the
Model 2040 1:1 Redundant Switch Installation and User’s Guide
(Document Number 93-005-26-A2).
Pin #
Function
Name
1
RSSI Monitor
RSSI
1
2
RSSI Monitor
RSSI2
2
3
RSSI Monitor
RSSI3
3
4
RSSI Monitor
RSSI4
4
5
RSSI Monitor
RSSI5
5
6
RSSI Monitor
RSSI6
6
7
RSSI Monitor
RSSI7
7
8
PDI Monitor
RSSI8
8
9
PDI Monitor
PDI1
1
10
PDI Monitor
PDI2
2
11
PDI Monitor
PDI3
3
12
PDI Monitor
PDI4
4
13
PDI Monitor
PDI5
5
14
PDI Monitor
PDI6
6
15
PDI Monitor
PDI7
7
16
PDI Monitor
PDI8
8
17
LSRI Monitor
LSR1
1
18
LSRI Monitor
LSR2
2
19
LSRI Monitor
LSR3
3
20
LSRI Monitor
LSR4
4
21
LSRI Monitor
LSR5
5
22
LSRI Monitor
LSR6
6
23
LSRI Monitor
LSR7
7
24
LSRI Monitor
LSR8
8
25
Chassis Ground
GND
Table 7 7180M Monitor Connector [J13] Pinout
7870 Interfacility Link Installation and User’s Guide
page 25
Foxcom proprietary information
4
Troubleshooting
The 7870D Interfacility Link unit was tested before it left the factory.
However if you are experiencing difficulties see the list below for
possible solutions. if you are still experiencing problems, attempt to
isolate and identify the malfunctioning unit before consulting
Foxcom’s technical support.
Table 8 Troubleshooting the Transmitter
Problem
Possible Cause
1. Laser LED not on
a. No DC power to the unit. Possible
power supply problem or AC power
input problem. Check the power
supply fuse.
b.Verify LSRI monitor is between -4.2
and -4.8VDC. If not, laser may have
overheated. Disconnect power or
remove plug and allow to cool. Try
again with better airflow.
c. If an optical power meter is avail-
able, measure the optical power out
of the transmitter. The power
should between 0.5 mW[-3 dBm]. If
an optical power meter is not avail-
able, use another receiver to deter-
mine if there is optical power
emerging from the transmitter (use
a 5 meter jumper cable). If there is
no optical power, then the transmit-
ter unit is malfunctioning.
If any or all the above are not within
the guidelines, the transmitter unit is
faulty.
2. The RF LED is not
lit
The input signal is less than -28 dBm;
verify RF signal strength [RSSI] is≤0.2
VDC. [See Table 4 7870T Transmitter
Pinout on page 20]. Even if slightly out
of range, the unit may still function,
although it will register an alarm
condition.
3. RF LED illuminated
- with no input
signal
Unit may be receiving stray RF “pick
up”. Solution: provide RF input or use
necessary termination input.`
Document no. 93-005-35-C5
Table 9 Troubleshooting the Receiver
Problem
Possible Cause
1. Lack of RF signal
present at Receiver,
yet optical power is
functioning.
If a spectrum analyzer or power meter
is not available then use a DVM and
adjust the gain control for RF signal
strength (RSSI) so that the reading is
> 0.2VDC. (See Table 5 7870R Receiver
Pinout on page 21).
Conclusion: If signal still not present
then transmitter input stage amplifier
or receiver amplifier is defective.
Contact factory.
2. No optical power,
LED not
illuminated.
a. Transmitter is not functioning, see
above.
b. There is a break or severe bend in
the fiber optic cable. Use an optical
power meter or another
functioning receiver unit to verify
optical power coming down the
fiber.
c.
The connector is dirty. Clean it.
d. Optical power too low, too many
splits, too long a distance (thus
exceeding optical budget). System
may still function without LED
illuminated although at reduced
performance.
3. Optical power light
illuminated with
disconnected optical
input.
Damaged (leaky) photodiode. Unit
may still function, otherwise contact
Factory for service.
4. The RF LED is not
illuminated.
Verify that the RF signal strength
(RSSI) is <0.2° VDC.
7870 Interfacility Link Installation and User’s Guide
page 27
Foxcom proprietary information
Appendix 1
Cleaning Fiber Optic Connections
Appendix 1.1 Cleaning Procedures for FC/APC Connectors ....................... 28
Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports................... 29
Appendix 1.2.1 Swab Method ........................................................................................... 29
Appendix 1.2.2 Compressed Air Method ......................................................................... 29
The unit has an FC/APC angle polished optical connector for very high optical return loss
performance. The units are specified into single mode fiber i.e. 9/125 micron core diameter.
Full performance is specified only for low return loss optical plant - meaning that the fiber
must be fusion spliced and all connections or splices must have a return loss greater than -60
dB. With these guidelines in mind, link lengths beyond 20 kilometers (DFB based products)
can be achieved with high performance. Specific performance and/or design assistance is
available by request from Foxcom.
If there is low/no signal or noisy signal at a Foxcom module, the connector should be cleaned.
Dirt on the inside connector tip can impair the flow of light causing problems in signal
transmission. Foxcom modules are sealed but dirt can occasionally enter during installation
and alignment.
The input and output optical ports of all Foxcom equipment are known in the fiber optic
world as bulkhead ports. Foxcom uses
FC/APC connectors.
The following materials are representative of the types of cleaning materials that should be
used for cleaning the fiber optic ports and connectors. They are available from several
suppliers.
Wiping clothes should be made of lint free alcohol free nonabrasive materials. Swabs should
have a tightly wrapped tip and be talcum- free. For removing dust from receptacles, a
canned compressed gas is recommended. Do not use commercial compressed air because of
risk of contamination.
Description
Manufacturer
Kim wipes
Kimberly Clark
Cletop Automatic Connector Cleaner
Cletop
fiber optic Swab
Cletop or FIS
fiber optic Compressed Air
Chemtronics
Table 10
Cleaning materials
Appendix 1.1 Cleaning Procedures for FC/APC Connectors
page 28
Document no. 93-005-35-C5
Appendix 1.1
Cleaning Procedures for FC/APC Connectors
Use a Kim Wipe to gently wipe the end face surface of the connector.
Alternatively a Cletop automatic connector cleaner can be used.
Figure 19
Wiping the connector with a Kim wiper
Figure 20
Wiping the connector with a Kim wiper [2]
Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports
7870 Interfacility Link Installation and User’s Guide
page 29
Foxcom proprietary information
Appendix 1.2
Cleaning Procedure for FC/APC Bulkhead Ports
Caution
Clean the transmitter and receiver optical ports only when there is evidence of
contamination or reduced performance.
Appendix 1.2.1 Swab Method
Using a clean fiber optic cleaning swab, gently wipe out the optical port. Discard the swab
after use.
Figure 21
Cleaning the Optical Port
Figure 22
Cleaning the Optical Port [2]
Appendix 1.2.2 Compressed Air Method
Using the extension tube of the compressed air, blow into the port to remove any dust or
debris. Do not allow the tube to touch the bottom of the port. Do not use commercial
compressed air due to potential oil contamination.
Note To prevent contamination, the optical ports should be connected or covered with a dust
cap at all times.
Use dry air or nitrogen only.
7870 Interfacility Link Installation and User’s Guide
page 31
Foxcom proprietary information
Appendix 2
Installing a Standalone Unit
To install the 7870T-STD or 7870R--STD Standalone:
1. Place the 7870 unit on the standalone flange, matching the holes.
2. Using four screws (#4 or #6) secure the unit and the flange to the wall.
3. Apply AC power to the standalone power supply unit.
4. Connect the 7870 unit to the power supply. The Laser LED should be lit.
All remaining steps are the same as in the product manual. See sections
2.1 Setting up the Transmitter on page8 and 2.3 Setting Up the Receiver on page10.
7870 Interfacility Link Installation and User’s Guide
page 33
Foxcom proprietary information
Appendix 3
The 2380 Relay Adapter
Appendix 3.1 Installing the 2380 Relay Adapter .................................... 34
Appendix 3.1.1 Parts Required for Installing the 2380 ..............................................34
Appendix 3.1.2 Mounting the the 2380 Relay Adapter ..............................................34
Appendix 3.2 2380 Dimensions and Front Panel Label......................... 36
Appendix 3.3 2380 Adapter Pinouts........................................................ 37
The following section describes how to install the 2380 Relay adapter
onto the 7180M Chassis. The 2380 Relay adapter assembly provides
dry contact output signals as an option to the standard open collector
signals available on the 7180M chassis backplane.
If the 2380 Relay adapter is ordered separately from the 7180M
chassis, it must mounted by the user. The 2380 is mounted directly
over the connectors on the 7180M backplane, as shown below.
Appendix 3.1 Installing the 2380 Relay Adapter
page 34
Document no. 93-005-35-C5
Appendix 3.1
Installing the 2380 Relay Adapter
Appendix 3.1.1 Parts Required for Installing the 2380
•2380 Relay Adapter
•Two pin guides
•Four one-inch screws
•Screw driver
Appendix 3.1.2 Mounting the the 2380 Relay Adapter
1.
Very Important: Disconnect the electricity before performing this pro-
cedure.
2. Make sure that you have all the needed equipment.
3. Install the pin guides.
Figure 23
Installing the guide pins
4. Mount the unit onto the pin guides.
Figure 24
Mounting the adapter
Appendix 3.1 Installing the 2380 Relay Adapter
7870 Interfacility Link Installation and User’s Guide
page 35
Foxcom proprietary information
5. Mount the four screws. The screws must be installed in the order
shown in Figures 25 and 26.
Figure 25
Mounting the Screws [1]
Figure 26
Mounting the screws [2]
Figure 27
Mounted 2380 Adapter
Caution
Use only the mounting screws provided by Foxcom. Other
screwa can permanently damage the unit!
Appendix 3.2 2380 Dimensions and Front Panel Label
page 36
Document no. 93-005-35-C5
Appendix 3.2
2380 Dimensions and Front Panel Label
Figure 28
2380 Dimensions
Figure 29
2380 Front Label
Appendix 3.3 2380 Adapter Pinouts
7870 Interfacility Link Installation and User’s Guide
page 37
Foxcom proprietary information
Appendix 3.3
2380 Adapter Pinouts
Note Alarms in Pins 1 through 16 function if there is either an RF or
Optical signals failure.
Table 11
2380 Alarms Pinouts [J2]
Pin Number
Function
Name
Slot Number
1
Alarm
NOP1
1
2
Alarm
COM1
1
3
Alarm
NOP2
2
4
Alarm
COM2
2
5
Alarm
NOP3
3
6
Alarm
COM3
3
7
Alarm
NOP4
4
8
Alarm
COM4
4
9
Alarm
NOP5
5
10
Alarm
COM5
5
11
Alarm
NOP6
6
12
Alarm
COM6
6
13
Alarm
NOP7
7
14
Alarm
COM7
7
15
Alarm
NOP8
8
16
Alarm
COM8
8
17
18
19
20
21
22
23
Main PS Alarm
MPSA
24
Standby PS Alarm
SPSA
25
Power Supply Comm.
PSCOM
Appendix 3.3 2380 Adapter Pinouts
page 38
Document no. 93-005-35-C5
Figure 30
2380 Pin Number
Table 12
7180M Monitor Connector [J4] Pinout
Pin #
Function
Name
Slot No.
1
RSSI Monitor
RSSI1
1
2
RSSI Monitor
RSSI2
2
3
RSSI Monitor
RSSI3
3
4
RSSI Monitor
RSSI4
4
5
RSSI Monitor
RSSI5
5
6
RSSI Monitor
RSSI6
6
7
RSSI Monitor
RSSI7
7
8
RSSI Monitor
RSSI8
8
9
PDI Monitor
PDI1
1
10
PDI Monitor
PDI2
2
11
PDI Monitor
PDI3
3
12
PDI Monitor
PDI4
4
13
PDI Monitor
PDI5
5
14
PDI Monitor
PDI6
6
15
PDI Monitor
PDI7
7
16
PDI Monitor
PDI8
8
17
LSRI Monitor
LSRI1
1
18
LSRI Monitor
LSRI2
2
19
LSRI Monitor
LSRI3
3
20
LSRI Monitor
LSRI4
4
21
LSRI Monitor
LSRI5
5
22
LSRI Monitor
LSRI6
6
23
LSRI Monitor
LSRI7
7
24
LSRI Monitor
LSRI8
8
25
Chassis Ground
7870 Interfacility Link Installation and User’s Guide
page 39
Foxcom proprietary information
Appendix 4
Pinout Charts and Diagrams
Figures 31 through 36 give detailed pinout information for the 7180M chassis, the 2380
Relay Adaptor and the 2040 RF Switch.
Figure 31 Standard 7180M and 7180M with 2380 Relay Adapter Pinout . . . . . . . . . . . . . . . . . . . 40
Figure 32 7180M and 2040 RF Switch Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 33 Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5 . . . . . . . . . . . . . . . . . . . 42
Figure 34 Pinout of 7180M jumper with 2040 RF switch in slot 5. . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 35 Pinout of 7180M jumper with 2040 RF switch in slot 5. . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 36 Pinout of 7180 jumper with transmitter and receiver units only . . . . . . . . . . . . . . . . . . . 45
Document no. 93-005-35-C5
page 40
Figure 31
Standard 7180M and 7180M with 2380 Relay Adapter Pinout
A1J1P9
P1 LNB1
P2 LNB2
P3 LNB3
P4 LNB4
P5 LNB5
P6 LNB6
P7 LNB7
P8 LNB8
A2J1P9
A3J1P9
A4J1P9
A5J1P9
A6J1P9
A7J1P9
A8J1P9
7180M LNB Powering Connector
Pinouts (J11)
P9 GND
7180M Monitor
Connector
Pinouts (J13)
A1J1P4
P1 RSSI1
P2 RSSI2
P3 RSSI3
P4 RSSI4
P5 RSSI5
P6 RSSI6
P7 RSSI7
P8 RSSI8
P9 PDI1
P10 PDI2
P11 PDI3
P12 PDI4
P13 PDI5
P14 PDI6
P15 PDI7
P16 PDI8
P17 LSRI1
P18 LSRI2
P19 LSRI3
P20 LSRI4
P21 LSRI5
P22 LSRI6
P23 LSRI7
P24 LSRI8
A2J1P4
A3J1P4
A4J1P4
A5J1P4
A6J1P4
A7J1P4
A8J1P4
A1J1P5
A2J1P5
A3J1P5
A4J1P5
A5J1P5
A6J1P5
A7J1P5
A8J1P5
A1J1P6
A1J1P6
A1J1P6
A1J1P6
A1J1P6
A1J1P6
A1J1P6
A1J1P6
P25 GND
2380 Monitor
Connector Pinouts (J4)
P1 RSSI1
P2 RSSI2
P3 RSSI3
P4 RSSI4
P5 RSSI5
P6 RSSI6
P7 RSSI7
P8 RSSI8
P9 PDI1
P10 PDI2
P11 PDI3
P12 PDI4
P13 PDI5
P14 PDI6
P15 PDI7
P16 PDI8
P17 LSRI1
P18 LSRI2
P19 LSRI3
P20 LSRI4
P21 LSRI5
P22 LSRI6
P23 LSRI7
P24 LSRI8
P25 GND
7180M Alarm Connector
Pinouts (J12)
A1J1P7
P1 RFAlm1
P2 RFAlm2
P3 RFAlm3
P4 RFAlm4
P5 RFAlm5
P6 RFAlm6
P7 RFAlm7
P8 RFAlm8
P9 OptAlm1
P10 OptAlm2
P11 OptAlm3
P12 OptAlm4
P13 OptAlm5
P14 OptAlm6
P15 OptAlm7
P16 OptAlm8
A2J1P7
A3J1P7
A4J1P7
A5J1P7
A6J1P7
A7J1P7
A8J1P7
A1J1P8
A2J1P8
A3J1P8
A4J1P8
A5J1P8
A6J1P8
A7J1P8
A8J1P8
P17
P18
P19
P20
P21 PS1
P22 PS1
P23 PS2
P24 PS2
P25 GND
2380 Alarm Connecter
Pinouts (J2)
P18
P19
P20
P21
P22
P23 Main PSA
P24 Spare PSA
P25 PSCOM
P1 RF-OptAlm1
P2 RF-OptAlm1
P3 RF-OptAlm2
P4 RF-OptAlm2
P17
P16 RF-OptAlm8
P15 RF-OptAlm8
P14 RF-OptAlm7
P13 RF-OptAlm7
P12 RF-OptAlm6
P11 RF-OptAlm6
P10 RF-OptAlm5
P9 RF-OptAlm5
P8 RF-OptAlm4
P7 RF-OptAlm4
P6 RF-OptAlm3
P5 RF-OptAlm3
*LSRI Signal in a Tx
Spare in an Rx
**No LNB Signal in IF Links,
or in L-Band Rx
Unit A1
Unit A2
Unit A3
Unit A4
Unit A5
Unit A6
Unit A7
Unit A8
PS 1 - A9
PS 2 - A10
P1 15VDC
P2 Spare
P3 GND
P4 RSSI5
P5 PDI5
P6 LSRI5/Spare*
P7 RFAlm5
P8 OptAlm5
P9 LNB5**
Tx/Rx
A5/J1
J13P5
J13P21
J12P5
J12P13
J13P13
P1 15VDC
P2 Spare
P3 GND
P4 RSSI6
P5 PDI6
P6 LSRI1/Spare*
P7 RFAlm6
P8 OptAlm6
P9 LNB6**
Tx/Rx
A6/J1
J13P6
J13P22
J12P6
J12P14
J13P14
P1 15VDC
P2 Spare
P3 GND
P4 RSSI7
P5 PDI7
P6 LSRI7/Spare*
P7 RFAlm7
P8 OptAlm7
P9 LNB7**
Tx/Rx
A7/J1
J13P7
J13P23
J12P7
J12P15
J13P15
P1 15VDC
P2 Spare
P3 GND
P4 RSSI8
P5 PDI8
P6 LSRI8/Spare*
P7 RFAlm8
P8 OptAlm8
P9 LNB8**
Tx/Rx
A8/J1
J13P8
J13P24
J12P8
J12P16
J13P16
P1 14VDC
P2 14VDC
P3 “O” Ring
P4 GND
P5 GND
P6 14VDC
P7 PSAlarm
P8 Spare
P9 GND
PS
P1 14VDC
P2 14VDC
P4 GND
P5 GND
P6 14VDC
P7 PSAlarm
P8 Spare
P9 GND
PS
P3 “O” Ring
P1 15VDC
P2 Spare
P3 GND
P4 RSSI3
P5 PDI3
P6 LSRI3/Spare*
P7 RFAlm3
P8 OptAlm3
P9 LNB3**
Tx/Rx
A3/J1
J13P3
J13P19
J12P3
J12P11
J13P11
P1 15VDC
P2 Spare
P3 GND
P4 RSSI4
P5 PDI4
P6 LSRI4/Spare*
P7 RFAlm4
P8 OptAlm4
P9 LNB4**
Tx/Rx
A4/J1
J13P4
J13P20
J12P4
J12P12
J13P12
P1 15VDC
P2 Spare
P3 GND
P4 RSSI1
P5 PDI1
P6 LSRI1/Spare*
P7 RFAlm1
P8 OptAlm1
P9 LNB1**
Tx/Rx
A1/J1
J13P1
J13P17
J12P1
J12P9
J13P9
P1 15VDC
P2 Spare
P3 GND
P4 RSSI2
P5 PDI2
P6 LSRI2/Spare*
P7 RFAlm2
P8 OptAlm2
P9 LNB2**
Tx/Rx
A2/J1
J13P2
J13P18
J12P2
J12P10
J13P10
Document no. 93-005-35-C5
page 41
Figure 32
7180M and 2040 RF Switch Pinout
*LSRI Signal in a Tx
Spare in an Rx
**No LNB Signal in IF Links,
or in L-Band Rx
P7 LNB7
P8 LNB8
A7J1P9
A8J1P9
P9 GND
7180M LNB Powering Connector
Pinouts (J11)
A1J1P4
P1 RSSI1
P3 RSSI3
P4 RSSI4
P6 RSSI6
P7 RSSI7
P8 RSSI8
P9 PDI1
P10 Local/Remote (Slot 2)
P11 PDI3
P12 PDI4
P14 PDI6
P15 PDI7
P16 PDI8
P17 LSRI1
P18 Remote Control A/B (Slot 2)
P19 LSRI3
P20 LSRI4
P22 LSRI6
P23 LSRI7
P24 LSRI8
A3J1P4
A4J1P4
A6J1P4
A7J1P4
A8J1P4
A1J1P5
A2J1P5
A3J1P5
A4J1P5
A5J1P5
A6J1P5
A7J1P5
A8J1P5
A1J1P6
A2J1P6
A3J1P6
A4J1P6
A5J1P6
A6J1P6
A7J1P6
A8J1P6
P13 Local/Remote (Slot 5)
P21 Remote Control A/B (Slot 5)
P25 GND
7180M Monitor Connector
Pinouts (J13)
A1J1P7
P1 RFAlm1
P3 RFAlm3
P4 RFAlm4
P6 RFAlm6
P7 RFAlm7
P8 RFAlm8
P9 OptAlm1
P11 OptAlm3
P12 OptAlm4
P14 OptAlm6
P15 OptAlm7
P16 OptAlm8
A3J1P7
A4J1P7
A6J1P7
A7J1P7
A8J1P7
A1J1P8
A3J1P8
A4J1P8
A6J1P8
A7J1P8
A8J1P8
A2J1P2
A5J1P2
P17 Swtich Failure (Slot 2)
P21 SPSNOP
P22 SPSCOM
P23 MPSNOP
P24 MPSCOM
P25 GND
P18 Swtich Failure (Slot 5)
A5J1P8
A6J1P8
A7J1P8
A8J1P8
7180M Alarm Connector
Pinouts (J12)
Unit A1
Unit A2
Unit A3
Unit A4
Unit A5
Unit A6
Unit A7
Unit A8
PS 1 - A9
PS 2 - A10
P1 15VDC
P2 Spare
P3 GND
P4 RSSI8
P5 PDI8
P6 LSRI8/Spare*
P7 RFAlm8
P8 OptAlm8
P9 LNB8**
Tx/Rx
A8/J1
J13P8
J13P24
J12P8
J12P16
J13P16
P1 15VDC
P2 Spare
P3 GND
P4 RSSI4
P5 PDI4
P6 LSRI4/Spare*
P7 RFAlm4
P8 OptAlm4
P9 Spare
J13P4
J13P20
J12P4
J12P12
J13P12
Rx A4/J1
P1 15VDC
P2 Switch Failure
P3 GND
P4 Chan B RSSI
P5 Local/Remote
P6 Remote Control A/B
P9 Chan B Optical Alarm
J12P17
J13P18
J13P10
2040 Switch A2/J1
P8 Chan A Optical Alarm
P4 Chan A RSSI
P1 15VDC
P2 Switch Failure
P3 GND
P4 Chan B RSSI
P5 Local/Remote
P6 Remote Control A/B
P9 Chan B Optical Alarm
J12P18
J13P21
J13P13
2040 Switch
A5/J1
P8 Chan A Optical Alarm
P4 Chan A RSSI
P1 15VDC
P2 Spare
P3 GND
P4 RSSI3
P5 PDI3
P6 LSRI3/Spare*
P7 RFAlm3
P8 OptAlm3
P9 Spare
RX
A3/J1
J13P3
J13P19
J12P3
J12P11
J13P11
P1 15VDC
P2 Spare
P3 GND
P4 RSSI6
P5 PDI6
P6 LSRI1/Spare*
P7 RFAlm6
P8 OptAlm6
P9 Spare
J13P6
J13P22
J12P6
J12P14
J13P14
RX
A6/J1
P1 15VDC
P2 Spare
P3 GND
P4 RSSI7
P5 PDI7
P6 LSRI7/Spare*
P7 RFAlm7
P8 OptAlm7
P9 LNB7**
Tx/Rx
A7/J1
J13P7
J13P23
J12P7
J12P15
J13P15
P1 14VDC
P2 14VDC
P3 “O” Ring
P4 GND
P5 GND
P6 14VDC
P7 PSAlarm
P8 Spare
P9 GND
PS
P1 14VDC
P2 14VDC
P4 GND
P5 GND
P6 14VDC
P7 PSAlarm
P8 Spare
P9 GND
PS
P3 “O” Ring
P1 15VDC
P2 Spare
P3 GND
P4 RSSI1
P5 PDI1
P6 LSRI1/Spare*
P7 RFAlm1
P8 OptAlm1
P9 Spare
J13P1
J13P17
J12P1
J12P9
J13P9
Rx A1/J1
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Not functional in this setup
Document no. 93-005-35-C5
Figure 33
Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5
7870 Interfacility Link Installation and User’s Guide
page 43
Foxcom proprietary information
Figure 34
Pinout of 7180M jumper with 2040 RF switch in slot 5
7870 Interfacility Link Installation and User’s Guide
page 45
Foxcom proprietary information
Figure 36
Pinout of 7180 jumper with transmitter and receiver units only