release to any third party, or any other unauthorized use, of any information contained herein is expressly forbidden. The information contained in this document is believed to be accurate as of the time of going to press. Specifications are subject to change without notice. Corporate Office Israel Beck Science Center 8 Hartom Street, Har Hotzvim P.O.Box 45092 Jerusalem 91450 Tel: +972-2-589-9888 Fax: +972-2-589-9898 US Office Princeton Forrestal Village 136 Main Street Suite 300 Princeton, NJ 08540 Tel: 609-514-1800 Toll free: 1-866-ONEPATH Fax: 609-514-1881 South Africa Office Block 4, Kingfisher Office Park 228 Siphosethu Rd. Mt. Edgecombe Durban, KwaZulu Natal Tel. +278 7.751.3911 Fax +278.6.501.6624 Website: www.foxcom.com e-mail: [email protected]

7870 Interfacility Link Installation and User’s Guide

page i Foxcom proprietary information Table of Contents Important Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Chapter 1 Introduction to the 7870 Interfacility Link ..................................... 1 1.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.2 Product Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1.3 Panel Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.4 Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Chapter 2 Installation........................................................................................ 7 2.1 Setting up the Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 2.2 Connecting the Fiber Optic Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 2.3 Setting Up the Receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 2.4 Powering the IFL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 2.4.1 7180M Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.5 Connecting the Back Panel Jumpers. . . . . . . . . . . . . . . . . . . . . . . . . .13 2.6 Aligning the Fiber Optic Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Chapter 3 Product Specifications.................................................................. 17 3.1 7870 Interfacility Link Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .17 3.2 Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 3.3 7870 Interfacility Link Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 3.3.1 Transmitter Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.2 Receiver Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4 7180M Chassis Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 3.4.1 7180M Alarm Connector Pinouts [J12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.4.2 7180M Monitor Connector Pinout [J13]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.4.3 7180M and Redundancy Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Chapter 4 Troubleshooting ............................................................................ 25 Appendix 1 Cleaning Fiber Optic Connections ........................................... 27 Appendix 1.1 Cleaning Procedures for FC/APC Connectors ..................... 28 Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports................. 29 Appendix 1.2.1 Swab Method .........................................................................................29 Appendix 1.2.2 Compressed Air Method .......................................................................29 Appendix 2 Installing a Standalone Unit...................................................... 31 Appendix 3 The 2380 Relay Adapter ............................................................ 33 Appendix 3.1 Installing the 2380 Relay Adapter.......................................... 34 Appendix 3.1.1 Parts Required for Installing the 2380 ...................................................34 Appendix 3.1.2 Mounting the the 2380 Relay Adapter ...................................................34 Appendix 3.2 2380 Dimensions and Front Panel Label .............................. 36 Appendix 3.3 2380 Adapter Pinouts.............................................................. 37 Appendix 4 Pinout Charts and Diagrams..................................................... 39

Document no. 93-005-35-C5

Figures Figure 1 Option Label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 2 7870T Transmitter Front and Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 3 7870R Receiver Front and Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 4 7870Transmitter Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 5 7870R Receiver Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 6 Typical Application of a 7870 Interfacility Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 7 7180M Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 8 Jumper Installation: Tx and Rx only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Figure 9 Jumper Installation: 2040 Switch in slot 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Figure 10 Jumper Installation: 2040 Switch in slot 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 11 Jumper Installation: 2040 Switch in slots 2 and 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 12 Fiber Optic Alignment Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 13 Unit dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 14 7810M Chassis Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 15 7870T Transmitter pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 16 7870R Receiver pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Figure 17 7180M Chassis rear view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 18 7180M Chassis Pin numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 19 Wiping the connector with a Kim wiper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 20 Wiping the connector with a Kim wiper [2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 21 Cleaning the Optical Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 22 Cleaning the Optical Port [2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 23 Installing the guide pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Figure 24 Mounting the adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Figure 25 Mounting the Screws [1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 26 Mounting the screws [2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 27 Mounted 2380 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 28 2380 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 29 2380 Front Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 30 2380 Pin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Figure 31 Standard 7180M and 7180M with 2380 Relay Adapter Pinout . . . . . . . . . . . . . . . . . . 40 Figure 32 7180M and 2040 RF Switch Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Figure 33 Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5. . . . . . . . . . . . . . . . . . 42 Figure 34 Pinout of 7180M jumper with 2040 RF switch in slot 5 . . . . . . . . . . . . . . . . . . . . . . . . 43 Figure 35 Pinout of 7180M jumper with 2040 RF switch in slot 5 . . . . . . . . . . . . . . . . . . . . . . . . 44 Figure 36 Pinout of 7180 jumper with transmitter and receiver units only . . . . . . . . . . . . . . . . . . 45 Tables Table 1 7870T Transmitter LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 2 7870R Receiver LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 3 7870 Interfacility Link Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Table 4 7870T Transmitter Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Table 5 7870R Receiver Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 6 7180M Alarm Connector [J12] Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 7 7180M Monitor Connector [J13] Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 8 Troubleshooting the Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Table 9 Troubleshooting the Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Table 10 Cleaning materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 11 2380 Alarms Pinouts [J2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table 12 7180M Monitor Connector [J4] Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

7870 Interfacility Link Installation and User’s Guide

page iii Foxcom proprietary information Important Information Warranty and Repair Policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii General Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Specific Product Warranty Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Returns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Limitations of Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Reporting Defects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Personal Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Equipment Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Warranty and Repair Policy Foxcom performs testing and inspection to verify the quality and reliability of our products. Foxcom uses every reasonable precaution to ensure that each unit meets specifications before shipment. Customers are asked to advise their incoming inspection, assembly, and test personnel as to the precautions required in handling and testing our products. Many of these precautions are to be found in this manual. The products are covered by the following warranties: General Warranty Foxcom warrants to the original purchaser all standard products sold by Foxcom to be free of defects in material and workmanship for 24 months from date of shipment from Foxcom. During the warranty period, Foxcom will repair or replace any product that Foxcom proves to be defective. This warranty does not apply to any product which has been subject to alteration, abuse, improper installation or application, accident, electrical or environmental over-stress, negligence in use, storage, transportation or handling. Specific Product Warranty Instructions All Foxcom products are warranted against defects in workmanship, materials and construction, and to no further extent. Any claim for repair or replacement of units found to be defective on incoming inspection by a customer must be made within 30 days of receipt of shipment, or within 30 days of discovery of a defect within the warranty period. This warranty is the only warranty made by Foxcom and is in lieu of all other warranties, expressed or implied. Foxcom sales agents or representatives are not authorized to make commitments on warranty returns.

Document no. 93-005-35-C5

Returns In the event that it is necessary to return any product against above warranty, the following procedure shall be followed: 1. Return authorization is to be received from Foxcom prior to returning any unit. Advise Foxcom of the model, serial number, and discrepancy. The unit may then be forwarded to Foxcom, transportation prepaid. Devices returned collect or without authorization may not be accepted. 2. Prior to repair, Foxcom will advise the customer of our test results and any charges for repairing customer-caused problems or out-of-warranty conditions etc. 3. Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment. Limitations of Liabilities Foxcom's liability on any claim, of any kind, including negligence for any loss or damage arising from, connected with, or resulting from the purchase order, contract, quotation, or from the performance or breach thereof, or from the design, manufacture, sale, delivery, installation, inspection, operation or use of any equipment covered by or furnished under this contact, shall in no case exceed the purchase price of the device which gives rise to the claim. EXCEPT AS EXPRESSLY PROVIDED HEREIN, FOXCOM MAKES NO WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY GOODS, PARTS AND SERVICES PROVIDED IN CONNECTION WITH THIS AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. FOXCOM SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT NOT LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND SERVICE HEREUNDER, OR THE PERFORMANCE, USE OF, OR INABILITY TO USE THE GOODS, PARTS AND SERVICE. The Company's exclusive warranty and the remedy provided for breach thereof shall not apply to: 1. Any Product used or operated other than pursuant to the Company's written instructions, 2. Damage or deficiencies resulting from accident, alteration, modification, misuse, tampering, negligence, improper maintenance, installation or abuse, 3. Use of any Product other than at the Installation Site, 4. Use of any Product that is defective or damaged due to misuse, accident, or neglect, or due to external electrical stress, lightning or other acts of nature, 5. Use of any Product by a person who is not any authorized employee of the Customer, or 6. Used other than as explicitly authorized in writing by the Company.

7870 Interfacility Link Installation and User’s Guide

page v Foxcom proprietary information Reporting Defects The units were inspected before shipment and found to be free of mechanical and electrical defects. Examine the units for any damage which may have been caused in transit. If damage is discovered, file a claim with the freight carrier immediately. Notify Foxcom as soon as possible. Note Keep all packing material until you have completed the inspection. Precautions Personal Safety OPTICAL RADIATION Applying power to the transmitter unit will create a laser energy source operating in Class I as defined by IEC 825-1. Use either an infrared viewer, optical power meter or fluorescent screen for optical output verification. AC POWER HAZARD The rackmount power supply line is EMI filtered. The chassis is connected to earth ground in compliance with safety requirements. Always use the 3-prong AC plug with earth ground to avoid possibility of electrical shock hazard to personnel. Equipment Safety To avoid damaging your product, please observe the following: 1. The output of the receiver is AC coupled and can withstand the bias from a satellite receiver. Do not exceed 25V DC bias. 2. The input of the transmitter has an optional built-in bias for inserting DC power up the coax to the LNB. Make certain that any equipment or test equipment connected to the transmitter input can withstand this bias. 3. Do not allow any dirt or foreign material to get into the optical connector bulkheads. This may cause damage to the polished optical connector end faces. 4. The optical fiber jumper cable bend radius is 3 cm. Smaller radii can cause excessive optical loss and/or fiber breakage. 5. If multiple transmitters are installed in the chassis allow sufficient room for adequate ventilation; otherwise the units may overheat causing possible safety hazard or equipment damage. 6. Fuses: The 7180M chassis does not have fuses. If the unit fails, pull the power supply out from the chassis and then push it back in. 7. When several units are installed on one 7180M chassis, ensure that the total units’ current consumption (including any LNB bias) does not exceed 6A.

7870 Interfacility Link Installation and User’s Guide

page 1 Foxcom proprietary information 1 Introduction to the 7870 Interfacility Link 1.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Product Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.3 Panel Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.4 Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 The 7870 IFL is a 10 – 200 MHz IF fiber optic link used primarily in short distance, single channel video applications with high input/ output power levels. The 7870 IFL consists of an optical transmitter (7870T) which receives signals from satellite modems, video modulators, or exciters and transmits them to an optical receiver (7870R) via singlemode fiber. The 7870T and 7870R modules plug into a 7180M, a 3U chassis and power supply, which enables expansion of the system to accommodate up to eight Sat-Light™ modules. Accessories include the Model 7001P Power Supply, the Model 2040 1:1 Redundant Switch, the Model 2100 Amplifier, and the Model 7050 Serial Optical Multiplexer, an asynchronous data transceiver. The 7870 IFL transmits all satellite modulation schemes - digital or analog. Any FM modulated RF signal is transmitted accurately. The RF signal is directly modulated and adds virtually no phase noise to the original signal. The direct modulation, along with extremely flat amplitude and group delay, guarantees low bit error rate (BER) and high signal quality, independent of distance. LEDs, and back panel monitors, and alarms allow for complete system status monitoring and for interfacing with monitor and control (M&C) systems. Gain Control at the Receiver sets the RF level.

Document no. 93-005-35-C5

1.1 Options The 7870 Interfacility Link comes with a variety of options: 1. 50 Ω Input/Output Impedance/BNC female connector; Standard impedance is 75 Ω/BNC, female connectors. 2. Standalone unit; The 7870 IFL can be installed as a standalone unit. If the 7870 is used as a standalone, a separate power supply must be used. On the side of the 7870T and the 7870R units is a label1 which lists the options. Under each option is a square. If the unit includes a particular option the square under the option should be marked. Figure 1 Option Label 1. The sticker includes options which are not relevant to the 7870 IFL.

1.2 Product Drawings

7870 Interfacility Link Installation and User’s Guide page 3 Foxcom proprietary information 1.2 Product Drawings Figure 2 7870T Transmitter Front and Rear Panel Figure 3 7870R Receiver Front and Rear Panel

1.3 Panel Descriptions

page 4 Document no. 93-005-35-C5 1.3 Panel Descriptions On the Front Panel of the 7870 IFL units are two LEDs. Both LEDs should be on when the unit is in use. T The LEDs on the Front Panel of the 7870 Transmitter and Receiver are: LED Name LED Function Laser Indicates if the laser is functioning RF Indicates RF signal level • Green: Input level is within 3 dB of specification (level is -2 to -28 dBm) • Amber: Input level exceeds maximum recommended level by 3 dB or more (level is >-2 dBm) • Off: Input level is below minimum recommended level by 3 dB or more (level is < -28 dBm Table 1 7870T Transmitter LEDs LED Name LED Function Opt. Indicates if the optical input power is above the minimal level [≥3 dBm] RF Indicates RF signal level • Green: Input level is within 3 dB of specification (level is -2 to -28 dBm) • Amber: Input level exceeds maximum recommended level by 3 dB or more (level is >-2 dBm) • Off: Input level is below minimum recommended level by 3 dB or more (level is < -28 dBm Table 2 7870R Receiver LEDs

1.4 Block Diagrams

7870 Interfacility Link Installation and User’s Guide page 5 Foxcom proprietary information 1.4 Block Diagrams Figure 4 7870Transmitter Block Diagram Figure 5 7870R Receiver Block Diagram

7870 Interfacility Link Installation and User’s Guide

page 7 Foxcom proprietary information 2 Installation Chapter 2 describes how to install the 7870 Interfacility Link units. Setting up the 7870E Transmitter/Receiver consists of: 2.1 Setting up the Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 Connecting the Fiber Optic Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.3 Setting Up the Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.4 Powering the IFL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.4.1 7180M Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.5 Connecting the Back Panel Jumpers . . . . . . . . . . . . . . . . . . . . . . . 13 2.6 Aligning the Fiber Optic Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Observe all warnings and cautions mentioned at the beginning of this manual (See Important Information on page iii). If after set-up you experience problems, see Chapter 4 Troubleshooting on page 25. Figure 6 Typical Application of a 7870 Interfacility Link

2.1 Setting up the Transmitter

page 8 Document no. 93-005-35-C5 2.1 Setting up the Transmitter 1. Place the 7870T in the 7180M Chassis. 2. Apply AC power to the chassis. The Power Supply and Laser LEDs should be lit. 3. Using an optical power meter, measure the optical power. Insert the meter’s cable into the Transmitter’s optical connector. Power levels should be 0.5 mW minimum (-3 dBm). Alternatively, use a DVM to measure the voltage at: • 7180M Rackmount: Pins J13-P17 through J13-P24 for the slot being measured (See Table 4 7870T Transmitter Pinout on page 20 for details regarding J13 pinouts). [7180M Rackmount] • Standalone: At pin #6 of the 9 pin connector [Standalone] The signal level should be -4.5 ± -0.3VDC. 4. On the rear panel, connect the coax cable to the RF Input Connector. The RF LED should be lit. 5. On the rear panel, connect the fiber optic cable to the Optical Connector. Note If either LED is not lit, see Chapter 4 Troubleshooting on page 25. Caution When monitoring the voltage outputs use only a high resistance DVM.

2.2 Connecting the Fiber Optic Cable

7870 Interfacility Link Installation and User’s Guide page 9 Foxcom proprietary information 2.2 Connecting the Fiber Optic Cable Before connecting the cable: 1. The fiber optic cable must be either fusion spliced or connected via FC/APC connectors. 2. Wipe the connector with a lint-free cotton cloth. 3. Note the polarity key of the optical connector before inserting. To connect the cable: 1. Line Up the Polarity Key. 2. Insert the connector 3. Tighten the connector Caution Do not apply any glue, silicon adhesive, or any other material to the fiber optic connector!

2.3 Setting Up the Receiver

page 10 Document no. 93-005-35-C5 2.3 Setting Up the Receiver 1. Place the 7870R Receiver in any of the 7180M Chassis, unless a 2040 RF Switch is installed. (See Figure 7 7180M Chassis Rear View on page 12.) Note If a 2040 RF Switch(es) is being installed, then slots 2 and/or 5 of the 7180M are reserved for the switch(es). 2. Apply AC power to the chassis. The Power Supply’s LED should be lit. 3. Using an optical power meter, measure the optical power coming to the Receiver from the fiber optic cable. The power levels of the Receiver should be the power level measured at the Transmitter minus the fiber loss2. Alternatively, use a DVM to measure the voltage at: • pins J13-P9 through J13-P16 for the slot being measured (See Table 5 7870R Receiver Pinout on page 21 for details regarding J13 pinouts) (7180M Rackmount). The voltage level should be 1 V for each 1 mW measured at the Receiver input. • at pin #5 of the 9 pin connector (standalone) 4. On the rear panel, connect the coax cable to the RF Output Connector. 5. Adjust the Gain Control Potentiometer to give the desired output power. Using a small screw driver, turn the potentiometer (located on the front panel) to increase or decrease the gain. Notes 1. The potentiometer is 10 turn potentiometer. • To increase the gain, turn the gain control clockwise. • To decrease the gain, turn the gain control counterclockwise. For more information see 2.6 Aligning the Fiber Optic Link on page15. 2. If the LED is not lit, see Chapter 4 Troubleshooting on page 25. 2. Fiber loss is defined as: (attenuation/km x length (km) of the fiber optic cable) + (0.5 dB × number of connectors). For example if a signal with an optical wavelength of 1310 nm is transmitted over a link 10 kilometers long which had two connectors the loss would be: (0.4 dB/km × 10 km) + (0.5 dB × 2) = 5.0 dB

2.4 Powering the IFL

7870 Interfacility Link Installation and User’s Guide page 11 Foxcom proprietary information 2.4 Powering the IFL • Transmitter power requirement: +14 VDC @ 200 mA • Receiver power requirement: +14 VDC @ 250 mA. • The Standalone Transmitter/Receiver is powered by a Foxcom supplied external DC power supply. • The Rackmount Transmitters/Receivers are plugged into the rackmount chassis. The chassis can accept and power up to eight units. Note At temperatures below10°C, the Transmitter’s internal heater will require an additional 100 mA. The Transmitter’s total power requirement will then be 300 mA. Caution Ensure that there is a good airflow around the chassis rackmount.

2.4 Powering the IFL

7870 Interfacility Link Installation and User’s Guide page 12 Foxcom proprietary information 2.4.1 7180M Chassis The 7180M Chassis provides power to the plug in units. The power supply is a switching type. Each plug-in regulates its own voltage. The power supply provides: • 14 VDC stable • AC input; 100 - 240 VAC • Units can be plugged in “hot standby” Figure 7 7180M Chassis Rear View

2.5 Connecting the Back Panel Jumpers

7870 Interfacility Link Installation and User’s Guide page 13 Foxcom proprietary information 2.5 Connecting the Back Panel Jumpers On the rear panel of the 7180M Back Panel are product selectors (JP1 to JP4). The 3 pin selectors (male) are the connecting point between the slots and the back panel. One pin is for the transmitter/receiver (Tx/Rx), one is for the optional 2040 1:1 Redundant Switch, and one is for the 7180M. A 2 pin jumper (female) is placed on the relevant pins to complete the connection between the 7180M and the units. For example, if a 2040 Switch is being used, the jumper is placed on the Switch-7180M pins. To connect the jumpers: 1. Each jumper has two sets of pins, upper and lower. The upper pins are labeled SW (Switch) and the lower pins Tx/Rx. 2. If the 7180M has Tx or Rx units only, place all jumpers on the lower two pins. Figure 8 Jumper Installation: Tx and Rx only 3. If the 2040 Switch is installed in Slot 2, place the JP1 and JP2 jumpers on the higher two pins and the JP3 and JP4 jumpers on the lower two pins. Figure 9 Jumper Installation: 2040 Switch in slot 2

2.5 Connecting the Back Panel Jumpers

7870 Interfacility Link Installation and User’s Guide page 14 Foxcom proprietary information 4. If the 2040 Switch is installed in Slot 5, place the JP1 and JP2 jumpers on the lower two pins and the JP3 and JP4 jumpers on the higher two pins. Figure 10 Jumper Installation: 2040 Switch in slot 5 5. If the 2040 Switch is installed in Slots 2 and 5, place the JP1, JP2, JP3, and JP4 jumpers on the higher two pins. Figure 11 Jumper Installation: 2040 Switch in slots 2 and 5

2.6 Aligning the Fiber Optic Link

7870 Interfacility Link Installation and User’s Guide page 15 Foxcom proprietary information 2.6 Aligning the Fiber Optic Link The final step in installing the 7870 Interfacility Link is re-adjusting the Receiver Gain Control for unity gain. To set the unity gain (standard version) 1. Set the Signal Generator to -15 dBm. Alternatively measure the operational input level. 2. Set up the system as shown in Figure 12 Fiber Optic Alignment Setup 3. Adjust the Receiver Gain Control for -15 dBm reading on the power meter. Figure 12 Fiber Optic Alignment Setup

3.1 7870 Interfacility Link Specifications

7870 Interfacility Link Installation and User’s Guide page 17 Foxcom proprietary information 3 Product Specifications 3.1 7870 Interfacility Link Specifications . . . . . . . . . . . . . . . . . . . . . . . 17 3.2 Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.3 7870 Interfacility Link Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.1 Transmitter Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.3.2 Receiver Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4 7180M Chassis Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.4.1 7180M Alarm Connector Pinouts [J12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.4.2 7180M Monitor Connector Pinout [J13]. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.4.3 7180M and Redundancy Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.1 7870 Interfacility Link Specifications RF Specifications Frequency range 10 - 200 MHz Flatness 10 – 200 MHz @ unity gain ± 0.4 dB [typical] Flatness @ 36 MHz ± 0.2 dB [max.] CNR 45 dB @ 36 MHz Noise Figure [50 Ω] @ unity gain / 1 dB optical loss @ unity gain / 8 dB optical loss1 28 dB [typical] 35 dB [typica] Noise Figure [75 Ω] @ unity gain / 1 dB optical loss @ unity gain / 8 dB optical loss1. 30 dB [typical] 37 dB [typica] OIP3 @ -10 dBm in / 0 dBm out 24 dBm Group delay variation @ 20 - 200 MHz <1 nSec Input /output impedance 75 Ω [50 Ω optional] Third order modulation - 50 dBc with 2 equal carrier, total input power -5 dBm Input signal range [total power] -25 to - 5 dBm Output signal range [total power] -25 to - 5 dBm Maximum input without damage +10 dBm Receiver gain control Manual RF connector BNC female [default] F, and SMA [optional] Test port coupling 20 dBc Table 3 7870 Interfacility Link Specifications 1. @ 10 dB Link Gain

3.1 7870 Interfacility Link Specifications

page 18 Document no. 93-005-35-C5 Note If the link is between 100 - 500 meters, foxcom technicians will limit the output power to +2 dBm/1.6 mW. This information must be given to Foxcom when ordering the link. Optical Specifications Optical Wavelength 1310 ± 10 nm Optical power output 0.5 mW/-2 dBm [minimum] Optical connector FC/APC Optical budget / distance 16 dB / 40 Km Optical return loss -60 dB Optical connector loss 0.5 dB/mated pair Physical Specifications Chassis capacity 8 plug-ins, and 2 power supplies Chassis size 19” × 3U × 7” Power for rackmount [max.] 100 to 240 VAC 50/60Hz 90 Watts Standalone size 5” × 4.8” × 1.3” Power for standalone Transmitter +14 VDC @ 200 mA max. [300 mA temp.< 10° C) Receiver +14VDC @ 250 mA max. Operating Temperature Range -10°C to +55°C Storage Temperature Range -40°C to +85°C All specifications are subject to change without prior notice

3.2 Model Dimensions

7870 Interfacility Link Installation and User’s Guide page 19 Foxcom proprietary information 3.2 Model Dimensions Figure 13 Unit dimensions Figure 14 7810M Chassis Dimensions

3.3 7870 Interfacility Link Pinouts

page 20 Document no. 93-005-35-C5 3.3 7870 Interfacility Link Pinouts 3.3.1 Transmitter Pinout Note If a 2380 Relay Adapter is installed RF and Optical Levels are measured together; the alarm indicates a problem in either the RF or Optical Levels. Figure 15 7870T Transmitter pinout Standalone 9-Pin Connector [J13] 7180M Chassis Backplane Connector 2380 Relay Adapter Connector Name Description 1 — — +14V Power 200 mA [max ≥ 10°C]1 2 — — Spare Not Used 3 J11-P9, J12-P25 J13-P25 J4-P25 GND Chassis Ground 4 J13-P1 to J13-P8 J4-P1 to J4-P8 RSSI RF signal strength indicator: range 0.2 - 10 V 5 J13-P9 to J13-P16 J4-P9 to J4-P16 PDI Indicates laser optical power: range -4.2 to 4.8 6 J13-P17 to J13-P24 J4-P17 to J4-P24 LSRI Indicates Laser Bias; Range 7 J12-P1 to J12-P8 J2: P1-P2 P3-P4, P5-P6 P7-P8, P9-P10 P11-P12, P13- P14 P15-P16 RFA RF Alarm: Open collector interface.2 Sinks current when RF level is low, up to 30 mA. 8 J12-P9 to J12-P16 See note below OPTA Optical Alarm: Open Collector Interface2.. Sinks current at low optical, up to 30 mA. 9 J11-P1 to J11-P6 Spare Not used Table 4 7870T Transmitter Pinout 1. 300 ma below 10°C 2. If the 2380 Relay Adapter is installed, the alarms are dry contact. See Appendix 3 The 2380 Relay Adapter on page 33.

3.3 7870 Interfacility Link Pinouts

7870 Interfacility Link Installation and User’s Guide page 21 Foxcom proprietary information 3.3.2 Receiver Pinouts Note If a 2380 Relay Adapter is installed RF and Optical Levels are measured together; the alarm indicates a problem in either the RF or optical levels. Figure 16 7870R Receiver pinout Caution When monitoring the voltage outputs use only a high resistance DVM. Standalone 9 Pin Connector [J14] 7180M Chassis Backplane Connector 2380 Relay Adapter Connector Name Description 1 — — +14V Power 350 mA 2 — — Spare Not Used 3 J11-P9 J12-P25 J13-P25 J4-P25 GND Chassis Ground 4 J13-P1 to J13-P8 J4-P1 to J4-P8 RSSI RF signal strength indicator: range 0.2 - 10 V 5 J13-P9 to J13-P16 J4-P9 to J4-P16 PDI Indicates input optical power: 1 V/ 1 m optical power 6 — — Spare Not used 7 J12-P1 to J12-P8 J2: P1-P2 P3-P4, P5-P6 P7-P8, P9-P10 P11-P12 P13-P14 P15-P16 RFA RF Alarm: Open collector interface.1 Sinks current when RF level is low, up to 30 mA. 8 J12-P9 to J12-P16 See note below OPTA Optical Alarm: Open Collector Interface1.. Sinks current at low optical, up to 30 mA. 9 — — Spare Not used Table 5 7870R Receiver Pinout 1. If the 2380 Relay Adapter is installed, the alarms are dry contact. See Appendix 3 The 2380 Relay Adapter on page 33.

3.4 7180M Chassis Pinouts

7870 Interfacility Link Installation and User’s Guide page 22 Foxcom proprietary information 3.4 7180M Chassis Pinouts The unit’s pins are found at the backplane of the 7180M chassis. The 7180M chassis backplane incorporates eight slots. Pinouts from the 9-pin connector at each slot are sent through the backplane assembly to the two 25-pin D-connectors, J12 and J13, and one 9-pin connector, J113. Any monitor voltages to be measured may be done between the chassis ground and the required pin. For more information about pinouts, see Appendix 4 Pinout Charts and Diagrams on page 41. Figure 17 7180M Chassis rear view Figure 18 7180M Chassis Pin numbers 3. In the 7870 the J11 connector is inoperative.

3.4 7180M Chassis Pinouts

7870 Interfacility Link Installation and User’s Guide page 23 Foxcom proprietary information 3.4.1 7180M Alarm Connector Pinouts [J12] Pin No. Function Name Slot No. 1 RF Alarm RfAlm1 1 2 RF Alarm RfAlm2 2 3 RF Alarm RfAlm3 3 4 RF Alarm RfAlm4 4 5 RF Alarm RfAlm5 5 6 RF Alarm RfAlm6 6 7 RF Alarm RfAlm7 7 8 RF Alarm RfAlm8 8 9 Optical Alarm OptAlm1 1 10 Optical Alarm OptAlm2 2 11 Optical Alarm OptAlm3 3 12 Optical Alarm OptAlm4 4 13 Optical Alarm OptAlm5 5 14 Optical Alarm OptAlm6 6 15 Optical Alarm OptAlm7 7 16 Optical Alarm OptAlm8 8 17 18 19 20 21 Standby Power Supply SPSNOP 22 Standby Power Supply SPSCOM 23 Main Power Supply MPSNOP 24 Main Power Supply MPSCOM 25 Chassis Ground GND Table 6 7180M Alarm Connector [J12] Pinouts

3.4 7180M Chassis Pinouts

page 24 Document no. 93-005-35-C5 3.4.2 7180M Monitor Connector Pinout [J13] 3.4.3 7180M and Redundancy Switching The 2040 Switch provides optional 1:1 redundancy switching for all Foxcom Interfacility Links. If the customer chooses to add redundancy switching to the link, the pin connector jumpers need to be moved. Detailed instructions on moving the jumpers are provided in the Model 2040 1:1 Redundant Switch Installation and User’s Guide (Document Number 93-005-26-A2). Pin # Function Name 1 RSSI Monitor RSSI 1 2 RSSI Monitor RSSI2 2 3 RSSI Monitor RSSI3 3 4 RSSI Monitor RSSI4 4 5 RSSI Monitor RSSI5 5 6 RSSI Monitor RSSI6 6 7 RSSI Monitor RSSI7 7 8 PDI Monitor RSSI8 8 9 PDI Monitor PDI1 1 10 PDI Monitor PDI2 2 11 PDI Monitor PDI3 3 12 PDI Monitor PDI4 4 13 PDI Monitor PDI5 5 14 PDI Monitor PDI6 6 15 PDI Monitor PDI7 7 16 PDI Monitor PDI8 8 17 LSRI Monitor LSR1 1 18 LSRI Monitor LSR2 2 19 LSRI Monitor LSR3 3 20 LSRI Monitor LSR4 4 21 LSRI Monitor LSR5 5 22 LSRI Monitor LSR6 6 23 LSRI Monitor LSR7 7 24 LSRI Monitor LSR8 8 25 Chassis Ground GND Table 7 7180M Monitor Connector [J13] Pinout

7870 Interfacility Link Installation and User’s Guide

page 25 Foxcom proprietary information 4 Troubleshooting The 7870D Interfacility Link unit was tested before it left the factory. However if you are experiencing difficulties see the list below for possible solutions. if you are still experiencing problems, attempt to isolate and identify the malfunctioning unit before consulting Foxcom’s technical support. Table 8 Troubleshooting the Transmitter Problem Possible Cause 1. Laser LED not on a. No DC power to the unit. Possible power supply problem or AC power input problem. Check the power supply fuse. b.Verify LSRI monitor is between -4.2 and -4.8VDC. If not, laser may have overheated. Disconnect power or remove plug and allow to cool. Try again with better airflow. c. If an optical power meter is avail- able, measure the optical power out of the transmitter. The power should between 0.5 mW[-3 dBm]. If an optical power meter is not avail- able, use another receiver to deter- mine if there is optical power emerging from the transmitter (use a 5 meter jumper cable). If there is no optical power, then the transmit- ter unit is malfunctioning. If any or all the above are not within the guidelines, the transmitter unit is faulty. 2. The RF LED is not lit The input signal is less than -28 dBm; verify RF signal strength [RSSI] is≤0.2 VDC. [See Table 4 7870T Transmitter Pinout on page 20]. Even if slightly out of range, the unit may still function, although it will register an alarm condition. 3. RF LED illuminated - with no input signal Unit may be receiving stray RF “pick up”. Solution: provide RF input or use necessary termination input.`

Document no. 93-005-35-C5

Table 9 Troubleshooting the Receiver Problem Possible Cause 1. Lack of RF signal present at Receiver, yet optical power is functioning. If a spectrum analyzer or power meter is not available then use a DVM and adjust the gain control for RF signal strength (RSSI) so that the reading is > 0.2VDC. (See Table 5 7870R Receiver Pinout on page 21). Conclusion: If signal still not present then transmitter input stage amplifier or receiver amplifier is defective. Contact factory. 2. No optical power, LED not illuminated. a. Transmitter is not functioning, see above. b. There is a break or severe bend in the fiber optic cable. Use an optical power meter or another functioning receiver unit to verify optical power coming down the fiber. c. The connector is dirty. Clean it. d. Optical power too low, too many splits, too long a distance (thus exceeding optical budget). System may still function without LED illuminated although at reduced performance. 3. Optical power light illuminated with disconnected optical input. Damaged (leaky) photodiode. Unit may still function, otherwise contact Factory for service. 4. The RF LED is not illuminated. Verify that the RF signal strength (RSSI) is <0.2° VDC.

7870 Interfacility Link Installation and User’s Guide

page 27 Foxcom proprietary information Appendix 1 Cleaning Fiber Optic Connections Appendix 1.1 Cleaning Procedures for FC/APC Connectors ....................... 28 Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports................... 29 Appendix 1.2.1 Swab Method ........................................................................................... 29 Appendix 1.2.2 Compressed Air Method ......................................................................... 29 The unit has an FC/APC angle polished optical connector for very high optical return loss performance. The units are specified into single mode fiber i.e. 9/125 micron core diameter. Full performance is specified only for low return loss optical plant - meaning that the fiber must be fusion spliced and all connections or splices must have a return loss greater than -60 dB. With these guidelines in mind, link lengths beyond 20 kilometers (DFB based products) can be achieved with high performance. Specific performance and/or design assistance is available by request from Foxcom. If there is low/no signal or noisy signal at a Foxcom module, the connector should be cleaned. Dirt on the inside connector tip can impair the flow of light causing problems in signal transmission. Foxcom modules are sealed but dirt can occasionally enter during installation and alignment. The input and output optical ports of all Foxcom equipment are known in the fiber optic world as bulkhead ports. Foxcom uses FC/APC connectors. The following materials are representative of the types of cleaning materials that should be used for cleaning the fiber optic ports and connectors. They are available from several suppliers. Wiping clothes should be made of lint free alcohol free nonabrasive materials. Swabs should have a tightly wrapped tip and be talcum- free. For removing dust from receptacles, a canned compressed gas is recommended. Do not use commercial compressed air because of risk of contamination. Description Manufacturer Kim wipes Kimberly Clark Cletop Automatic Connector Cleaner Cletop fiber optic Swab Cletop or FIS fiber optic Compressed Air Chemtronics Table 10 Cleaning materials

Appendix 1.1 Cleaning Procedures for FC/APC Connectors

page 28 Document no. 93-005-35-C5 Appendix 1.1 Cleaning Procedures for FC/APC Connectors Use a Kim Wipe to gently wipe the end face surface of the connector. Alternatively a Cletop automatic connector cleaner can be used. Figure 19 Wiping the connector with a Kim wiper Figure 20 Wiping the connector with a Kim wiper [2]

Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports

7870 Interfacility Link Installation and User’s Guide page 29 Foxcom proprietary information Appendix 1.2 Cleaning Procedure for FC/APC Bulkhead Ports Caution Clean the transmitter and receiver optical ports only when there is evidence of contamination or reduced performance. Appendix 1.2.1 Swab Method Using a clean fiber optic cleaning swab, gently wipe out the optical port. Discard the swab after use. Figure 21 Cleaning the Optical Port Figure 22 Cleaning the Optical Port [2] Appendix 1.2.2 Compressed Air Method Using the extension tube of the compressed air, blow into the port to remove any dust or debris. Do not allow the tube to touch the bottom of the port. Do not use commercial compressed air due to potential oil contamination. Note To prevent contamination, the optical ports should be connected or covered with a dust cap at all times. Use dry air or nitrogen only.

7870 Interfacility Link Installation and User’s Guide

page 31 Foxcom proprietary information Appendix 2 Installing a Standalone Unit To install the 7870T-STD or 7870R--STD Standalone: 1. Place the 7870 unit on the standalone flange, matching the holes. 2. Using four screws (#4 or #6) secure the unit and the flange to the wall. 3. Apply AC power to the standalone power supply unit. 4. Connect the 7870 unit to the power supply. The Laser LED should be lit. All remaining steps are the same as in the product manual. See sections 2.1 Setting up the Transmitter on page8 and 2.3 Setting Up the Receiver on page10.

7870 Interfacility Link Installation and User’s Guide

page 33 Foxcom proprietary information Appendix 3 The 2380 Relay Adapter Appendix 3.1 Installing the 2380 Relay Adapter .................................... 34 Appendix 3.1.1 Parts Required for Installing the 2380 ..............................................34 Appendix 3.1.2 Mounting the the 2380 Relay Adapter ..............................................34 Appendix 3.2 2380 Dimensions and Front Panel Label......................... 36 Appendix 3.3 2380 Adapter Pinouts........................................................ 37 The following section describes how to install the 2380 Relay adapter onto the 7180M Chassis. The 2380 Relay adapter assembly provides dry contact output signals as an option to the standard open collector signals available on the 7180M chassis backplane. If the 2380 Relay adapter is ordered separately from the 7180M chassis, it must mounted by the user. The 2380 is mounted directly over the connectors on the 7180M backplane, as shown below.

Appendix 3.1 Installing the 2380 Relay Adapter

page 34 Document no. 93-005-35-C5 Appendix 3.1 Installing the 2380 Relay Adapter Appendix 3.1.1 Parts Required for Installing the 2380 •2380 Relay Adapter •Two pin guides •Four one-inch screws •Screw driver Appendix 3.1.2 Mounting the the 2380 Relay Adapter 1. Very Important: Disconnect the electricity before performing this pro- cedure. 2. Make sure that you have all the needed equipment. 3. Install the pin guides. Figure 23 Installing the guide pins 4. Mount the unit onto the pin guides. Figure 24 Mounting the adapter

Appendix 3.1 Installing the 2380 Relay Adapter

7870 Interfacility Link Installation and User’s Guide page 35 Foxcom proprietary information 5. Mount the four screws. The screws must be installed in the order shown in Figures 25 and 26. Figure 25 Mounting the Screws [1] Figure 26 Mounting the screws [2] Figure 27 Mounted 2380 Adapter Caution Use only the mounting screws provided by Foxcom. Other screwa can permanently damage the unit!

Appendix 3.2 2380 Dimensions and Front Panel Label

page 36 Document no. 93-005-35-C5 Appendix 3.2 2380 Dimensions and Front Panel Label Figure 28 2380 Dimensions Figure 29 2380 Front Label

Appendix 3.3 2380 Adapter Pinouts

7870 Interfacility Link Installation and User’s Guide page 37 Foxcom proprietary information Appendix 3.3 2380 Adapter Pinouts Note Alarms in Pins 1 through 16 function if there is either an RF or Optical signals failure. Table 11 2380 Alarms Pinouts [J2] Pin Number Function Name Slot Number 1 Alarm NOP1 1 2 Alarm COM1 1 3 Alarm NOP2 2 4 Alarm COM2 2 5 Alarm NOP3 3 6 Alarm COM3 3 7 Alarm NOP4 4 8 Alarm COM4 4 9 Alarm NOP5 5 10 Alarm COM5 5 11 Alarm NOP6 6 12 Alarm COM6 6 13 Alarm NOP7 7 14 Alarm COM7 7 15 Alarm NOP8 8 16 Alarm COM8 8 17 18 19 20 21 22 23 Main PS Alarm MPSA 24 Standby PS Alarm SPSA 25 Power Supply Comm. PSCOM

Appendix 3.3 2380 Adapter Pinouts

page 38 Document no. 93-005-35-C5 Figure 30 2380 Pin Number Table 12 7180M Monitor Connector [J4] Pinout Pin # Function Name Slot No. 1 RSSI Monitor RSSI1 1 2 RSSI Monitor RSSI2 2 3 RSSI Monitor RSSI3 3 4 RSSI Monitor RSSI4 4 5 RSSI Monitor RSSI5 5 6 RSSI Monitor RSSI6 6 7 RSSI Monitor RSSI7 7 8 RSSI Monitor RSSI8 8 9 PDI Monitor PDI1 1 10 PDI Monitor PDI2 2 11 PDI Monitor PDI3 3 12 PDI Monitor PDI4 4 13 PDI Monitor PDI5 5 14 PDI Monitor PDI6 6 15 PDI Monitor PDI7 7 16 PDI Monitor PDI8 8 17 LSRI Monitor LSRI1 1 18 LSRI Monitor LSRI2 2 19 LSRI Monitor LSRI3 3 20 LSRI Monitor LSRI4 4 21 LSRI Monitor LSRI5 5 22 LSRI Monitor LSRI6 6 23 LSRI Monitor LSRI7 7 24 LSRI Monitor LSRI8 8 25 Chassis Ground

7870 Interfacility Link Installation and User’s Guide

page 39 Foxcom proprietary information Appendix 4 Pinout Charts and Diagrams Figures 31 through 36 give detailed pinout information for the 7180M chassis, the 2380 Relay Adaptor and the 2040 RF Switch. Figure 31 Standard 7180M and 7180M with 2380 Relay Adapter Pinout . . . . . . . . . . . . . . . . . . . 40 Figure 32 7180M and 2040 RF Switch Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Figure 33 Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5 . . . . . . . . . . . . . . . . . . . 42 Figure 34 Pinout of 7180M jumper with 2040 RF switch in slot 5. . . . . . . . . . . . . . . . . . . . . . . . . . 43 Figure 35 Pinout of 7180M jumper with 2040 RF switch in slot 5. . . . . . . . . . . . . . . . . . . . . . . . . . 44 Figure 36 Pinout of 7180 jumper with transmitter and receiver units only . . . . . . . . . . . . . . . . . . . 45

Document no. 93-005-35-C5

page 40 Figure 31 Standard 7180M and 7180M with 2380 Relay Adapter Pinout A1J1P9 P1 LNB1 P2 LNB2 P3 LNB3 P4 LNB4 P5 LNB5 P6 LNB6 P7 LNB7 P8 LNB8 A2J1P9 A3J1P9 A4J1P9 A5J1P9 A6J1P9 A7J1P9 A8J1P9 7180M LNB Powering Connector Pinouts (J11) P9 GND 7180M Monitor Connector Pinouts (J13) A1J1P4 P1 RSSI1 P2 RSSI2 P3 RSSI3 P4 RSSI4 P5 RSSI5 P6 RSSI6 P7 RSSI7 P8 RSSI8 P9 PDI1 P10 PDI2 P11 PDI3 P12 PDI4 P13 PDI5 P14 PDI6 P15 PDI7 P16 PDI8 P17 LSRI1 P18 LSRI2 P19 LSRI3 P20 LSRI4 P21 LSRI5 P22 LSRI6 P23 LSRI7 P24 LSRI8 A2J1P4 A3J1P4 A4J1P4 A5J1P4 A6J1P4 A7J1P4 A8J1P4 A1J1P5 A2J1P5 A3J1P5 A4J1P5 A5J1P5 A6J1P5 A7J1P5 A8J1P5 A1J1P6 A1J1P6 A1J1P6 A1J1P6 A1J1P6 A1J1P6 A1J1P6 A1J1P6 P25 GND 2380 Monitor Connector Pinouts (J4) P1 RSSI1 P2 RSSI2 P3 RSSI3 P4 RSSI4 P5 RSSI5 P6 RSSI6 P7 RSSI7 P8 RSSI8 P9 PDI1 P10 PDI2 P11 PDI3 P12 PDI4 P13 PDI5 P14 PDI6 P15 PDI7 P16 PDI8 P17 LSRI1 P18 LSRI2 P19 LSRI3 P20 LSRI4 P21 LSRI5 P22 LSRI6 P23 LSRI7 P24 LSRI8 P25 GND 7180M Alarm Connector Pinouts (J12) A1J1P7 P1 RFAlm1 P2 RFAlm2 P3 RFAlm3 P4 RFAlm4 P5 RFAlm5 P6 RFAlm6 P7 RFAlm7 P8 RFAlm8 P9 OptAlm1 P10 OptAlm2 P11 OptAlm3 P12 OptAlm4 P13 OptAlm5 P14 OptAlm6 P15 OptAlm7 P16 OptAlm8 A2J1P7 A3J1P7 A4J1P7 A5J1P7 A6J1P7 A7J1P7 A8J1P7 A1J1P8 A2J1P8 A3J1P8 A4J1P8 A5J1P8 A6J1P8 A7J1P8 A8J1P8 P17 P18 P19 P20 P21 PS1 P22 PS1 P23 PS2 P24 PS2 P25 GND 2380 Alarm Connecter Pinouts (J2) P18 P19 P20 P21 P22 P23 Main PSA P24 Spare PSA P25 PSCOM P1 RF-OptAlm1 P2 RF-OptAlm1 P3 RF-OptAlm2 P4 RF-OptAlm2 P17 P16 RF-OptAlm8 P15 RF-OptAlm8 P14 RF-OptAlm7 P13 RF-OptAlm7 P12 RF-OptAlm6 P11 RF-OptAlm6 P10 RF-OptAlm5 P9 RF-OptAlm5 P8 RF-OptAlm4 P7 RF-OptAlm4 P6 RF-OptAlm3 P5 RF-OptAlm3 *LSRI Signal in a Tx Spare in an Rx **No LNB Signal in IF Links, or in L-Band Rx Unit A1 Unit A2 Unit A3 Unit A4 Unit A5 Unit A6 Unit A7 Unit A8 PS 1 - A9 PS 2 - A10 P1 15VDC P2 Spare P3 GND P4 RSSI5 P5 PDI5 P6 LSRI5/Spare* P7 RFAlm5 P8 OptAlm5 P9 LNB5** Tx/Rx A5/J1 J13P5 J13P21 J12P5 J12P13 J13P13 P1 15VDC P2 Spare P3 GND P4 RSSI6 P5 PDI6 P6 LSRI1/Spare* P7 RFAlm6 P8 OptAlm6 P9 LNB6** Tx/Rx A6/J1 J13P6 J13P22 J12P6 J12P14 J13P14 P1 15VDC P2 Spare P3 GND P4 RSSI7 P5 PDI7 P6 LSRI7/Spare* P7 RFAlm7 P8 OptAlm7 P9 LNB7** Tx/Rx A7/J1 J13P7 J13P23 J12P7 J12P15 J13P15 P1 15VDC P2 Spare P3 GND P4 RSSI8 P5 PDI8 P6 LSRI8/Spare* P7 RFAlm8 P8 OptAlm8 P9 LNB8** Tx/Rx A8/J1 J13P8 J13P24 J12P8 J12P16 J13P16 P1 14VDC P2 14VDC P3 “O” Ring P4 GND P5 GND P6 14VDC P7 PSAlarm P8 Spare P9 GND PS P1 14VDC P2 14VDC P4 GND P5 GND P6 14VDC P7 PSAlarm P8 Spare P9 GND PS P3 “O” Ring P1 15VDC P2 Spare P3 GND P4 RSSI3 P5 PDI3 P6 LSRI3/Spare* P7 RFAlm3 P8 OptAlm3 P9 LNB3** Tx/Rx A3/J1 J13P3 J13P19 J12P3 J12P11 J13P11 P1 15VDC P2 Spare P3 GND P4 RSSI4 P5 PDI4 P6 LSRI4/Spare* P7 RFAlm4 P8 OptAlm4 P9 LNB4** Tx/Rx A4/J1 J13P4 J13P20 J12P4 J12P12 J13P12 P1 15VDC P2 Spare P3 GND P4 RSSI1 P5 PDI1 P6 LSRI1/Spare* P7 RFAlm1 P8 OptAlm1 P9 LNB1** Tx/Rx A1/J1 J13P1 J13P17 J12P1 J12P9 J13P9 P1 15VDC P2 Spare P3 GND P4 RSSI2 P5 PDI2 P6 LSRI2/Spare* P7 RFAlm2 P8 OptAlm2 P9 LNB2** Tx/Rx A2/J1 J13P2 J13P18 J12P2 J12P10 J13P10

Document no. 93-005-35-C5

page 41 Figure 32 7180M and 2040 RF Switch Pinout *LSRI Signal in a Tx Spare in an Rx **No LNB Signal in IF Links, or in L-Band Rx P7 LNB7 P8 LNB8 A7J1P9 A8J1P9 P9 GND 7180M LNB Powering Connector Pinouts (J11) A1J1P4 P1 RSSI1 P3 RSSI3 P4 RSSI4 P6 RSSI6 P7 RSSI7 P8 RSSI8 P9 PDI1 P10 Local/Remote (Slot 2) P11 PDI3 P12 PDI4 P14 PDI6 P15 PDI7 P16 PDI8 P17 LSRI1 P18 Remote Control A/B (Slot 2) P19 LSRI3 P20 LSRI4 P22 LSRI6 P23 LSRI7 P24 LSRI8 A3J1P4 A4J1P4 A6J1P4 A7J1P4 A8J1P4 A1J1P5 A2J1P5 A3J1P5 A4J1P5 A5J1P5 A6J1P5 A7J1P5 A8J1P5 A1J1P6 A2J1P6 A3J1P6 A4J1P6 A5J1P6 A6J1P6 A7J1P6 A8J1P6 P13 Local/Remote (Slot 5) P21 Remote Control A/B (Slot 5) P25 GND 7180M Monitor Connector Pinouts (J13) A1J1P7 P1 RFAlm1 P3 RFAlm3 P4 RFAlm4 P6 RFAlm6 P7 RFAlm7 P8 RFAlm8 P9 OptAlm1 P11 OptAlm3 P12 OptAlm4 P14 OptAlm6 P15 OptAlm7 P16 OptAlm8 A3J1P7 A4J1P7 A6J1P7 A7J1P7 A8J1P7 A1J1P8 A3J1P8 A4J1P8 A6J1P8 A7J1P8 A8J1P8 A2J1P2 A5J1P2 P17 Swtich Failure (Slot 2) P21 SPSNOP P22 SPSCOM P23 MPSNOP P24 MPSCOM P25 GND P18 Swtich Failure (Slot 5) A5J1P8 A6J1P8 A7J1P8 A8J1P8 7180M Alarm Connector Pinouts (J12) Unit A1 Unit A2 Unit A3 Unit A4 Unit A5 Unit A6 Unit A7 Unit A8 PS 1 - A9 PS 2 - A10 P1 15VDC P2 Spare P3 GND P4 RSSI8 P5 PDI8 P6 LSRI8/Spare* P7 RFAlm8 P8 OptAlm8 P9 LNB8** Tx/Rx A8/J1 J13P8 J13P24 J12P8 J12P16 J13P16 P1 15VDC P2 Spare P3 GND P4 RSSI4 P5 PDI4 P6 LSRI4/Spare* P7 RFAlm4 P8 OptAlm4 P9 Spare J13P4 J13P20 J12P4 J12P12 J13P12 Rx A4/J1 P1 15VDC P2 Switch Failure P3 GND P4 Chan B RSSI P5 Local/Remote P6 Remote Control A/B P9 Chan B Optical Alarm J12P17 J13P18 J13P10 2040 Switch A2/J1 P8 Chan A Optical Alarm P4 Chan A RSSI P1 15VDC P2 Switch Failure P3 GND P4 Chan B RSSI P5 Local/Remote P6 Remote Control A/B P9 Chan B Optical Alarm J12P18 J13P21 J13P13 2040 Switch A5/J1 P8 Chan A Optical Alarm P4 Chan A RSSI P1 15VDC P2 Spare P3 GND P4 RSSI3 P5 PDI3 P6 LSRI3/Spare* P7 RFAlm3 P8 OptAlm3 P9 Spare RX A3/J1 J13P3 J13P19 J12P3 J12P11 J13P11 P1 15VDC P2 Spare P3 GND P4 RSSI6 P5 PDI6 P6 LSRI1/Spare* P7 RFAlm6 P8 OptAlm6 P9 Spare J13P6 J13P22 J12P6 J12P14 J13P14 RX A6/J1 P1 15VDC P2 Spare P3 GND P4 RSSI7 P5 PDI7 P6 LSRI7/Spare* P7 RFAlm7 P8 OptAlm7 P9 LNB7** Tx/Rx A7/J1 J13P7 J13P23 J12P7 J12P15 J13P15 P1 14VDC P2 14VDC P3 “O” Ring P4 GND P5 GND P6 14VDC P7 PSAlarm P8 Spare P9 GND PS P1 14VDC P2 14VDC P4 GND P5 GND P6 14VDC P7 PSAlarm P8 Spare P9 GND PS P3 “O” Ring P1 15VDC P2 Spare P3 GND P4 RSSI1 P5 PDI1 P6 LSRI1/Spare* P7 RFAlm1 P8 OptAlm1 P9 Spare J13P1 J13P17 J12P1 J12P9 J13P9 Rx A1/J1 Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup Not functional in this setup

Document no. 93-005-35-C5

Figure 33 Pinout of 7180M Jumper with 2040 RF Switch in slots 2 and 5

7870 Interfacility Link Installation and User’s Guide

page 43 Foxcom proprietary information Figure 34 Pinout of 7180M jumper with 2040 RF switch in slot 5

7870 Interfacility Link Installation and User’s Guide

page 45 Foxcom proprietary information Figure 36 Pinout of 7180 jumper with transmitter and receiver units only

Other Transmitter Manuals