1. Remove the fan. (Refer to section 2.2.2)

2. Remove the shroud. (See Figure 8) 3. Re-install the components by referring to the removal procedure, above. 2.3 ELECTRICAL PARTS 2.3.1 OVERLOAD PROTECTOR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the terminal cover. (See Figure 9) 4. Remove all the leads from the overload protector. 5. Remove the overload protector. 6. Re-install the components by referring to the removal procedure, above. 2.3.2 COMPRESSOR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Di ...

3.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling. Ineffective Cooling Check outdoor coil (heat exchanger) & the fan operation. Check gas leakage. Repair gas leak. Replacement of unit if the unit is beyond repair. Satisfactory operation with temperature difference of inlet & outlet air ; 18~26°F. Check heat load increase. Clean co ...

2 ROW 11STACKS

3 ROW 11STACKS 2 ROW 10STACKS 3 ROW 12STACKS 2 ROW 16STACKS 2 ROW 17STACKS 2 ROW 17STACKS(L) TURBO FAN PROPELLER TYPE FAN WITH SLINGER RING 2/3 3/3 6 POLES R OTAR Y S WITCH R E MOTE CONTR OLLE R THER MOSTAT THER MISTOR VE R TICAL LOUVE R (R IGHT & LE FT) HOR ...

Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable

of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW MANIFOLD GAUGE B Figure 16A-Pulling Vacuum Figure 16B-Charging A B EXTERNAL VACUUM PUMP A CHARGING CYLINDER LOW HI B C ...

Loc No FRIEDRICH

Description 130410 67302922 BASE ASSEMBLY,SINGLE 130910 67303710 CABINET ASSEMBLY,SINGLE 135312 67306013 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306108 GRILLE,INLET 135500 67300310 COVER 147581 67306206 LOUVER,HORIZONTAL 147582-1 67306258 LOUVER,VERTICAL 147582-2 67306259 LOUVER,VERTICAL 148000 67303908 BRACE 149980 67303112 SHROUD ASSEMBLY 152302 67304307 FILTER ASSEMBLY,AIR CLEANER 237200 67305508 PANEL,CONTROL 238310 67500116 ESCUTCHEON 263230 67307807 THERMISTOR ASSEMBLY 264110 67300018 POWER CORD ASSEMBLY 267110 67307701 REMOTE CONTROLLER ASSEMBLY 268712 67307613 ...

Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air

conditioner or if there are obstacles between the Remote Control unit and the air conditioner. POWER BUTTON To turn the air conditioner ON. To turn the air conditioner OFF, push the button again. This button takes priority over any other buttons. TEMPERATURE SETTING BUTTON This button can automatically control temperature of the room. The temperature can be set within a range of 60'F to 86'F by 1'F. OPERATION MODE SELECTION BUTTON Every time you push this button, it will ...

354(13 / ")

29 490(19 / ) 3 8" 29(1 / ) 5 32" 18( / ) 23 32" 126.5(4 / ) 31 32" 32 510 20 3 32 —13— 3. TROUBLESHOOTING GUIDE 3.1 OUTSIDE DIMENSIONS unit: mm(inch) DEFROST HEAT COOL INDOOR DESIRED ENERGY SAVER AIR PURYFIER AUTO RESTART FAN FAN DRY 380(14 / ") 31 567(22 / ) 1 16" 29(1 / ) 5 32" 18( / ) 23 32" 111(4 / ) 3 8" 32 600 23 5 8 MODEL: ZQ08B10,CP08A10,ZQ10B10 MODEL:CP10A10,CP12A10 ...

Friedrich ZQ08B10 user guide recommended for: MW09Y3G, MW09Y1E, OHS Series, MR18Y3F, VERT-I-PAK R410A.

⚠️ Download Safety

The Air Conditioner Service and parts manual (28 pages) is completely safe to download (last scan date: 04/01/2026).

Related PDF Instructions for Friedrich ZQ08B10:

Air Conditioner Equipment: Frequently Requested

Have some Questions about Friedrich ZQ08B10 Device?

Get valuable and actionable advices from other Friedrich ZQ08B10 device users. Describe your problem or question, regarding the using of ZQ08B10, in as much detail as possible, and other users will be able to answer you.