Sanyo THW3672R Specifications
Read Online
Read the Sanyo THW3672R Specifications online using the built-in PDF viewer.
Text of the manual
Ceiling Suspended Air Conditioner
Power
V/PH/Hz
230/208/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max
Lift Difference, Max
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
Weight
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
(A) 15-35 Indoor-Outdoor
(A) 15-35 Indoor-Outdoor
General Data (at 230V)
1
(A) 16.4-17.5
(W) -
Propeller
18-7/64-1
Direct Inverter
(RPM) 8 - 830
(W) 1-90
15.1
(Pints/H) 10.0
(BTU/H) 31,200 (9,500-31,200)
(BTU/H) 19,800
(BTU/H) 11,400
(Uncrated) 9-7/16 x 62-1/32 x 26-3/8
(W) 3,840/3,840
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rif ed
(in.) 3/8”
6.17
Split System Submittal Data
Electric Expansion Valve
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
2-14.1
(sq.ft.) 7.26
(lbs.) 84 143
(A) 18.2/20.1
(in. O.D. Discharge) 3/8”
(in. O.D. Suction) 5/8”
DC Rotary Inverter
(High) 1942
(A) 17.3
R410A
(in.) H x W x D
(Crated) 12-15/32 x 66-1/16 x 31-1/16
Indoor Outdoor
(cu.ft.) 14.8 13.0
Indoor Outdoor
(lbs.) 97 161
(dB-A) 52
Centrifugal
5-29/32 - 4
3 & Auto
(RPM, High) 4-1040
(W) 1-100
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Rif ed
(in.) 9/32”
3-14.9
(sq.ft.) 3.51
(HI/Med/Lo) 1100/930/750
(A) 0.8
(in.) (1-1/4)
(Hi) (dB-A) 42
Flare
165
50 (Outdoor lower), 100 (Outdoor higher)
(Uncrated) 30-23/32 x 37 x 13-3/8
(Crated) 34-31/32 x 39-31/32 x 16-3/32
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com
Feature
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Self-Diagnosis
Air Filter
Option
Refrigerant Line Set
Fresh Air Intake
Condensate Drain Pump
Wireless Remote Controller
Non-Removeable Remo-con Bracket
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 0F DB
Built-In
Built-In
Washable, Anti-Mold
Available
Knock-Out
Knock-Out
Available
Available
Microprocessor
LCD Wired Type, Temp. Sensor Built In
(Horizontal) Manual
72HR, ON/OFF
IC Thermostat
Built-In
(Vertical) Automatic
Dimensional Data for 36T72R
Indoor unit : TH3672R
Dimensional Data for 36T72R
Indoor unit : TH3672R