Rules For Safe Operation
International Electrical Symbols
Rotary Switch
Display Symbols
Measurement Operation
A.
AC Voltage Measurement
B.
DC Current Measurement
C.
Square Wave Output
D.
Battery Test
E.
Diodes Test
F.
Measuring Resistance
G.
DC Voltage Measurement
Table of Contents (1)
1
Model UT20B: OPERATING MANUAL
Table of Contents (2)
Title
General Specifications
Accuracy Specifications
A.
AC Voltage
B.
DC Current
C.
Square Wave Output
D.
Battery Test
E.
Diodes Test
F.
Resistance Test
G.
DC Voltage
Maintenance
A.
General Service
B.
Replacing the Battery
C.
Replacing the Fuses
2
Model UT20B: OPERATING MANUAL
This Operation Manual covers information on safety and cautions. Please read the
relevant information carefully and observe all the Warnings and Notes strictly.
Warning
To avoid electric shock or personal injury, read the "Safety Information" and
"Rules for Safe Operation" carefully before using the Meter.
Digital Multimeter Model UT20B (hereafter referred to as "the Meter") is a pocket-
size hand-held digital multimeter with advanced design, multiple functions, and
reliable performance. Because of its small size, it is very convenience for user to
work with it. It is very easy to operate, so it is suitable to the beginner of multimeter.
Besides the basic functions, the Meter also has some extraordinary functions such
as battery test and square wave output.
Overview
3
Model UT20B: OPERATING MANUAL
Open the packing case and take out the Meter. Check the following items carefully
to see any missing or damaged part:
In the event you find any missing or damage, please contact your dealer immediately.
Item
1
2
3
Description
Operating Manual
Test Lead (affixed onto the Meter)
12V Battery (A23) (installed)
Qty
1 piece
1 pair
1 piece
Unpacking Inspection
4
Model UT20B: OPERATING MANUAL
This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage
category (CAT. II 300V) and double insulation.
CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient
voltage overvoltages than CAT. III.
Use the Meter only as specified in this operating manual, otherwise the protection
provided by the Meter may be impaired.
In this manual, a Warning identifies conditions and actions that pose hazards to
the user, or may damage the Meter or the equipment under test.
A Note identifies the information that user should pay attention on.
International electrical symbols used on the Meter and in this Operating Manual are
explained on page 9.
Safety Information
5
Model UT20B: OPERATING MANUAL
To avoid possible electric shock or personal injury, and to avoid possible
damage to the Meter or to the equipment under test, adhere to the following
rules:
l
Before using the Meter inspect the case. Do not use the Meter if it is
damaged or the case (or part of the case) is removed. Look for cracks or
missing plastic. Pay attention to the insulation around the connectors.
l
Inspect the test leads for damaged insulation or exposed metal. Check
the test leads for continuity.
l
Do not apply more than the rated voltage, as marked on the Meter, between
the terminals or between any terminal and grounding.
l
The rotary switch should be placed in the right position and no any
changeover of range shall be made during measurement is conducted to
prevent damage of the Meter.
Rules For Safe Operation (1)
6
Model UT20B: OPERATING MANUAL
Rules For Safe Operation (2)
l
When the Meter working at an effective voltage over 60V in DC or 30V rms
in AC, special care should be taken for there is danger of electric shock.
l
Use the proper function and range for your measurements.
l
Do not use or store the Meter in an environment of high temperature,
humidity, explosive, inflammable and strong magnetic field. The
performance of the Meter may deteriorate after dampened.
l
When using the test leads, keep your fingers behind the finger guards.
l
Disconnect circuit power and discharge all high-voltage capacitors before
testing resistance, diodes or current.
l
Before measuring current, check the Meter's fuses and turn off power to
the circuit before connecting the Meter to the circuit.
l
Replace the battery as soon as the battery indicator
appears. With a
low battery, the Meter might produce false readings that can lead to electric
shock and personal injury.
l
Turn the Meter power off before opening the Meter case.
l
When servicing the Meter, use only the same model number or identical
7
Model UT20B: OPERATING MANUAL
Rules For Safe Operation (3)
electrical specifications replacement parts.
l
The internal circuit of the Meter shall not be altered at will to avoid damage
of the Meter and any accident.
l
Soft cloth and mild detergent should be used to clean the surface of the
Meter when servicing. No abrasive and solvent should be used to prevent
the surface of the Meter from corrosion, damage and accident.
l
The Meter is suitable for indoor use.
l
Turn the Meter off when it is not in use and take out the battery when not
using for a long time.
l
Constantly check the battery as it may leak when it has been using for
some time, replace the battery as soon as leaking appears. A leaking
battery will damage the Meter.
8
Model UT20B: OPERATING MANUAL
International Electrical Symbols
AC (Alternating Current)
DC (Direct Current)
Grounding.
Double Insulated.
Deficiency of Built-In Battery.
Diode.
Fuse.
Warning. Refer to the Operating Manual.
Conforms to Standards of European Union.
9
Model UT20B: OPERATING MANUAL
Below table indicated for information about the rotary switch positions.
Rotary Switch
Rotary Switch Position
OFF
V
A
Ω
V
Function
Turn on or off the power.
AC voltage measurement range from 200V to 300V.
DC current measurement range from 2000µA to 200mA.
Square wave output.
Battery test (1.5V & 9V battery).
Diode test.
Resistance measurement range from 200Ω to 2000kΩ.
DC voltage measurement range from 200mV to 300V.
Display Symbols
Symbol
Meaning
Indicates negative reading.
The input value is too large for the selected range.
10
Model UT20B: OPERATING MANUAL
Measurement Operation (1)
A. AC Voltage Measurement
Warning
To avoid harms to you or damages to the Meter from electric shock, please
do not attempt to measure voltages higher than 300V rms although readings
may be obtained.
The AC voltage measurement positions are: 200V and 300V. To measure AC Voltage,
connect the Meter as follows:
1.
Set the rotary switch to an appropriate measurement positions in V
range.
2.
Connect the test leads across with the object being measured.
The measured value shows on the display, which is effective value of sine wave
(mean value response).
11
Model UT20B: OPERATING MANUAL
Measurement Operation (2)
Note
l
If the value of voltage to be measured is unknown, use the maximum
measurement position (300V) and reduce the range step by step until a
satisfactory reading is obtained.
l
In each range, the Meter has an input impedance of approx. 0.5MΩ. This loading
effect can cause measurement errors in high impedance circuits. If the circuit
impedance is less than or equal to 1kΩ, the error is negligible (0.2% or less).
l
When AC voltage measurement has been completed, disconnect the connection
between the testing leads and the circuit under test.
12
Model UT20B: OPERATING MANUAL
Measurement Operation (3)
B. DC Current Measurement
Warning
Never attempt an in-circuit current measurement where the open-circuit voltage
between the circuit and ground is greater than 300V.
If the fuse burns out during measurement, the Meter may be damaged or the
operator himself may be hurt. Use proper terminals, function, and range for
the measurement. When the testing leads are connected to the current terminals,
do not parallel them across any circuit.
The current measurement has 3 measurement positions on the rotary switch: 2000µA,
20mA and 200mA.
To measure current, do the following:
1. Turn off power to the circuit. Discharge all high-voltage capacitors.
2.
Set the rotary switch to an appropriate measurement position in A
range.
13
Model UT20B: OPERATING MANUAL
Measurement Operation (4)
3.
Break the current path to be tested. Connect the red test lead to the more
positive side of the break and the black test lead to the more negative side of
the break.
4.
Turn on power to the circuit.
The measured value shows on the display.
Note
l
If the value of current to be measured is unknown, use the maximum measurement
position (200mA) and reduce the range step by step until a satisfactory reading
is obtained.
l
When current measurement has been completed, disconnect the connection
between the testing leads and the circuit under test.
14
Model UT20B: OPERATING MANUAL
Measurement Operation (5)
C. Square Wave Output
Warning
To avoid damages to the Meter, do not allow output terminals to reach higher
than 10V.
To measure square wave output proceed as follows:
1.
Set the rotary switch to
.
2.
Connect the test leads across with the object being measured.
The measured value shows on the display.
Note
l
The frequency is approx. 50Hz.
l
The output voltage range will be over 3Vpp when it is loaded 1MΩ.
l
When square wave output testing has been completed, disconnect the connection
between the testing leads and the circuit under test.
15
Model UT20B: OPERATING MANUAL
Measurement Operation (6)
D. Battery Test
To test the battery proceed as follows:
1.
Set the rotary switch to the 1.5V or 9V measurement position in
range.
2.
Connect the test leads across with the battery being measured ensuring the
polarity is correct.
The measured value shows on the display, which is the voltage between the
cathode and anode of the battery.
Note
l
When battery testing has been completed, disconnect the connection between
the testing leads and the battery under test.
16
Model UT20B: OPERATING MANUAL
To avoid damages to the Meter or to the devices under test, disconnect circuit
power and discharge all the high-voltage capacitors before testing diodes.
Use the diode test to check diodes, transistors, and other semiconductor devices.
The diode test sends a current through the semiconductor junction, and then measures
the voltage drop across the junction. A good silicon junction drops between 0.5V
and 0.8V.
To test a diode out of a circuit, connect the Meter as follows:
1.
Set the rotary switch to
.
Measurement Operation (7)
17
Model UT20B: OPERATING MANUAL
For forward voltage drop readings on any semiconductor component, place the
red test lead on the component’s anode and place the black test lead on the
component’s cathode.
The measured value shows on the display.
Note
l
In a circuit, a good diode should still produce a forward voltage drop reading
of 0.5V to 0.8V; however, the reverse voltage drop reading can vary depending
on the resistance of other pathways between the probe tips.
l
Connect the test leads to the proper terminals as said above to avoid error
display.
l
The LCD will display " " indicating open-circuit for wrong connection.
l
The unit of diode is Volt (V), displaying the positive-connection voltage-drop
value.
l
When diode testing has been completed, disconnect the connection between
the testing leads and the circuit under test.
Measurement Operation (8)
18
Model UT20B: OPERATING MANUAL
F. Measuring Resistance
Warning
To avoid damages to the Meter or to the devices under test, disconnect circuit
power and discharge all the high-voltage capacitors before measuring resistance.
The resistance measurement positions are: 200Ω, 2000Ω, 20kΩ, 200kΩ and 2000kΩ.
To measure resistance, connect the Meter as follows:
1.
Set the rotary switch to an appropriate measurement position in Ω range.
2.
Connect the test leads across with the object being measured.
The measured value shows on the display.
Measurement Operation (9)
19
Model UT20B: OPERATING MANUAL
If the value of resistance to be measured is unknown, use the maximum
measurement position (2000kΩ) and reduce the range step by step until a
satisfactory reading is obtained.
l
The test leads can add 0.1Ω to 0.2Ω of error to resistance measurement. To
obtain precision readings in low-resistance measurement, that is the range of
200Ω, short-circuit the input terminals beforehand and record the reading
obtained (called this reading as X). (X) is the additional resistance from the
test lead.
Then use the equation:
measured resistance value (Y) - (X) = precision readings of resistance.
l
For high-resistance measurement (>1MΩ), it is normal taking several seconds
to obtain a stable reading.
l
If Ω reading with shorted test leads is not 0.5Ω, check for loose test leads, or
incorrect function selection.
Measurement Operation (10)
20
Model UT20B: OPERATING MANUAL
The LCD displays " " indicating open-circuit for the tested resistor or the resistor
value is higher than the maximum range of the Meter.
l
When resistance measurement has been completed, disconnect the connection
between the testing leads and the circuit under test.
G. DC Voltage Measurement
Warning
To avoid harms to you or damages to the Meter from electric shock, please
do not attempt to measure voltages higher than 300V / 300V rms although
readings may be obtained.
The DC voltage measurement positions are: 200mV, 2000mV, 20V, 200V and 300V.
To measure DC Voltage, connect the Meter as follows:
1.
Set the rotary switch to an appropriate measurement positions in V
range.
Measurement Operation (11)
21
Model UT20B: OPERATING MANUAL
Connect the test leads across with the object being measured.
The measured value shows on the display.
Note
l
If the value of voltage to be measured is unknown, use the maximum measurement
position (300V) and reduce the range step by step until a satisfactory reading
is obtained.
l
In each range, the Meter has an input impedance of 1MΩ. This loading effect
can cause measurement errors in high impedance circuits. If the circuit impedance
is less than or equal to 1kΩ, the error is negligible (0.1% or less).
l
When DC voltage measurement has been completed, disconnect the connection
between the testing leads and the circuit under test.
Measurement Operation (12)
22
Model UT20B: OPERATING MANUAL
Maximum Voltage between any
Terminals and Grounding
l
Fused Protection Input Terminal
l
Maximum Display
l
Measurement Speed
l
Temperature
l
Relative Humidity
l
Altitude
l
Battery Type
l
Battery Deficiency
l
Negative reading
l
Overloading
l
Dimensions (HxWxL)
l
Weight
l
Safety/Compliances
l
Certification
General Specifications
:300V rms.
:0.2A, 250V fast type, φ5x20 mm.
:Display: 1999.
:Updates 2.5 times /second.
:Operating: 0
oC~40
oC (32
oF~104
oF).
Storage: -10
oC~50
oC (14
oF~122
oF).
: 75% @ 0
oC - 30
oC; 50% @ 31
oC - 40
oC.
:Operating: 2000 m; Storage: 10000 m.
:One piece of 12V Battery (A23).
:Display:
.
:Display: .
:Display:
:95 x 52 x 26mm.
:Approx. 100g (battery included).
:IEC61010 CAT.II 300V overvoltage and double
insulation standard.
:
23
Model UT20B: OPERATING MANUAL
Accuracy Specifications (1)
Accuracy: (a% reading + b digits), guarantee for 1 year.
Operating temperature: 23
oC 5
oC.
Relative humidity: <75%.
Temperature coefficient: 0.1 x (specified accuracy) / 1
oC.
A.
AC Voltage
Range
200V
300V
Resolution
100 mV
1V
Accuracy
(2.5%+15)
Overload Protection
300V DC or AC rms
Remarks:
l
Input impedance: approx. 0.5MΩ.
l
Displays effective value of sine wave (mean value response).
l
Frequency response 45Hz ~ 400Hz.
24
Model UT20B: OPERATING MANUAL
Accuracy Specifications (2)
C.
Square Wave Output
Range
Remark
Output approx. at 50Hz square wave. As a simple signal
source with 47kΩ resistance output.
B.
DC Current
Range
2000µA
20mA
200mA
Resolution
1µA
10µA
100µA
Accuracy
(2.5%+10)
Overload Protection
0.2A, 250V fast type fuse, φ5x20mm.
25
Model UT20B: OPERATING MANUAL
Accuracy Specifications (3)
E. Diodes Test
D. Battery Test
Range
1.5V
9V
Internal Resistance
30Ω
1.8kΩ
Overload Protection
Maximum current: 50mA.
Maximum current: 5mA.
Remark:
l
Displays battery’s voltage value between the cathode and anode.
Range
Resolution
1mV
Remarks
l
Open circuit voltage approximate 3V.
l
Displays approximate forward voltage drop: 0.5V~0.8V.
26
Model UT20B: OPERATING MANUAL
Accuracy Specifications (4)
G. DC Voltage
Range
200mV
2000mV
20V
200V
300V
Resolution
0.1mV
1mV
10mV
100mV
1V
Overload Protection
300V DC or AC rms
Accuracy
(1.5%+2)
(2.5%+2)
Remark: Input impedance: approx.1MΩ.
F.
Resistance Test
Range
200Ω
2000Ω
20kΩ
200kΩ
2000kΩ
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
Accuracy
(2.5%+5)
27
Model UT20B: OPERATING MANUAL
This section provides basic maintenance information including battery and fuse
replacement instruction.
Warning
Do not attempt to repair or service your Meter unless you are qualified to do
so and have the relevant calibration, performance test, and service information.
To avoid electrical shock or damage to the Meter, do not get water inside the
case.
A.
General Service
l
Periodically wipe the case with a damp cloth and mild detergent. Do not use
abrasives or solvents.
l
To clean the terminals with cotton bar with detergent, as dirt or moisture in the
terminals can affect readings.
28
Model UT20B: OPERATING MANUAL
Turn the Meter to OFF position when it is not in use and take out the battery
when not using for a long time.
l
Do not store the Meter in a place of humidity, high temperature and strong
magnetic field.
Maintenance (2)
29
Model UT20B: OPERATING MANUAL
Replacing the Battery
Warning
To avoid false readings, which could lead to possible electric shock or personal
injury, replace the battery as soon as the battery indicator "
" appears.
To replace the battery:
1.
Turn the Meter to OFF position.
2.
Remove the screw from case bottom, and separate the case bottom from the
case top.
3.
Remove the battery from the battery compartment.
4. Replace the battery with a new 12V battery (A23).
5. Rejoin the case bottom and case top, and reinstall the screw.
30
Model UT20B: OPERATING MANUAL
Replacing the Fuses
Warning
To avoid electrical shock or arc blast, or personal injury or damage to the
Meter, use specified fuses ONLY in accordance with the following procedure.
To replace the Meter’s fuse:
1. Turn the Meter to OFF position.
2. Remove the screw from case bottom, and separate the case bottom from the
case top.
3.
Remove the fuse by gently prying one end loose, and then take out the fuse
from its bracket.
4.
Install ONLY replacement fuses with the identical type and specification as
follows and make sure the fuse is fixed firmly in the bracket.
Fuse: 0.2A, 250V, fast type, φ5x20mm.
31
Model UT20B: OPERATING MANUAL
~ END ~
This operating manual is subject to change without notice.
5.
Rejoin the case bottom and case top,and reinstall the screw .
Replacement of the fuses is seldom required.Burning of a fuse always results from
improper operation.
32
Model UT20B: OPERATING MANUAL
Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITED
Address: Dong Fang Da Dao, Bei Shan Dong Fang Industrial
Development District, Hu Men Town, Dong Guan City,
Guang Dong Province, China
Headquarters: Uni-Trend International Limited
Address: Rm901, 9/F, Nanyang Plaza 57 Hung To Road
Kwun Tong Kowloon, Hong Kong
Tel: (852) 2950 9168
Fax: (852) 2950 9303
Email: [email protected]
http://www.uni-trend.com
Copyright 2001 Uni-Trend International Limited.
All rights reserved.
34
Model UT20B: OPERATING MANUAL