UNI-T UT56 Operating Manual
| Brand: | UNI-T |
| Category: | Multimeter |
| Model: | UT56 (Operating Manual) |
| File Type: | |
| File Size: | 0.51 Mb |
| Pages: | 17 |
Text of UNI-T UT56 Operating Manual
UNI-T UT56 A. Your Meters Feature
B. Specifications
C. Making Measurements
D. Maintenance
E. Accessories
F. Using Holster
G. Using Strap
Introduction
UT56 is one type of UNI-T brand new UT50 series
Multimeters with 4 1/2 digits, which has steady
function and is a highly reliable hand-held measuring
instrument. The Meter uses large scale of integrated
circuit with double integrated A/D converter as its
core and has full range overload protection. The
UNI-T UT56 l Use the Meter only as specified in this
manual, otherwise the protection provided
by the Meter may be impaired.
l Do not operate the Meter before the cabinet
has been closed and screwed safely as
terminal can carry voltage.
l Make sure before each measurement the
Meter is set to the suitable range.
l Before using the Meter, please inspect
the cabinet and test leads for damaged
insulation or exposed
l Replace the battery as soon as the battery
indicator" "appears. With a low battery,
the Meter might produce false readings
that can lead to electric shock and personal
injury.
l Turn off the Meter once finished measuring.
Fetch out the battery, when the meter will
not be used for long period.
l Do not operate the M
UNI-T UT56 B-3 Direct Current Current (DC Current)
2mA
20mA
200mA
20A
0.1µV
1µV
10µV
1mV
Range
Resolution
(0.8% +5)
Accuracy
(2% +10)
(0.5% +5)
Overload protection: Below 200mA with 0.3
A/250V Fused. No fuse protection on 20A.
Max current input: 20A (above 10A for 15 seconds
maximum).
Measuring voltage drop: Full ranges are 200mV.
B-4 Alternate Current Current (AC Current)
2mA
20mA
200mA
20A
0.1µV
1µV
10µV
1mV
Range
Resolution
(1.2% +10)
Accuracy
(2.5% +1
Overload protection: All ranges are 250VDC
or AC RMS.
Caution:
1) At 200MΩ range, test lead is short circuit, the
LCD display 1000 digits, deduct the 1000
digits from the measured reading during
Input sensitivity: <200mVrms, Max. input
scope 30Vrms.
Overload protection: 250Vrms.
2-8 Diode and Continuity Beeper
Overload protection: 250V DC or AC RMS.
B-9 Transistor hFE test
Range
Remark
Measuring Condition
Display Diode
Forward Voltage
Value, unit is "V"
Forward DC Current abt
1mA, Backward DC
Voltage abt3.0V
Beeper sounds when
Resistance < 50Ω.
C. Making Measurements
Caution:
1 On/Off Switch 2 Capacitance jack
3 Liquid Crystal Display 4 Date Hold Switch
5 Rotary switch 6 Transistor jack
7 Input jack
(1) If there is no display or is shown on the
LCD when the Meter is switched on, replace
the battery ASAP.
(2) Never exceed the maximum input voltage or
current limits shown besides the input jacks
, otherwise t