Read the Sanyo DSR-3000P Instruction Manual online using the built-in PDF viewer.
Text of the manual
Digital Video Recorder
DSR-3000P
Instruction Manual
English
GB
Bedienungsanleitung
Deutsch
D
Manuel d’instructions
Français
F
Manual de Instrucciones
Español
E
Manuale di Istruzioni
Italiano
I
About this manual
Before installing and using this unit, please read this
manual carefully. Be sure to keep it handy for later
reference.
Über diese Anleitung
Lesen Sie bitte diese Bedienungsanleitung vor der
Installation und der Verwendung des Gerätes sorgfältig
durch. Bewahren Sie die Anleitung zum späteren
Nachschlagen auf.
À propos de ce manuel
Avant d’installer et d’utiliser cet appareil, veuillez lire ce
manuel attentivement. Assurez-vous de le garder à
portée de la main pour référence ultérieure.
Acerca de este manual
Antes de instalar y usar este aparato, lea detenidamente
este manual. Asegúrese de guardarlo a mano para
futuras referencias.
Nota su questo manuale
Leggere attentamente questo manuale prima di passare
all’installazione ed all’uso di questo apparecchio.
Conservare il manuale in un posto sicuro per riferimenti
futuri.
WARNING: TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR OTHER MOISTURE.
To avoid electrical shock, do not open the cabinet.
Refer servicing to qualified personnel only.
If the power supply cord (AC power cord) of this
appliance is damaged, it must be replaced. Return
to a SANYO Authorised Service Centre for
replacement of the cord.
Location
For safe operation and satisfactory performance of your
unit, keep the following in mind when selecting a place for
its installation:
Shield it from direct sunlight and keep it away from sources
of intense heat.
Avoid dusty or humid places.
Avoid places with insufficient ventilation for proper heat
dissipation. Do not block the ventilation holes at the top and
bottom of the unit. Do not place the unit on a carpet
because this will block the ventilation holes.
Install the unit in a horizontal position only.
Avoid locations subject to strong vibrations.
Avoid moving the unit between cold and hot locations.
Do not place the unit directly on top of a monitor TV, as this
may cause playback or recording problems.
Avoiding Electrical Shock and Fire
Do not handle the power cord with wet hands.
Do not pull on the power cord when disconnecting it from an
AC wall outlet. Grasp it by the plug.
If any liquid is spilled on the unit, unplug the power cord
immediately and have the unit inspected at a
factory-authorised service centre.
Do not place anything directly on top of this unit.
SERVICE
This unit is a precision instruments and if treated with care,
will provide years of satisfactory performance. However, in
the event of a problem, the owner is advised not to attempt
to make repairs or open the cabinet. Servicing should
always be referred to your dealer or Sanyo Authorized
Service Centre.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Discard used batteries according to the manufacture’s
instructions.
English
1
This digital video recorder can be used to store images recorded by
a monitoring camera onto its built-in hard disk.
• Equipped with a large-capacity 3.5-inch hard disk drive.
• Recording and playback of images can be carried out using
digital signals from a multiplexer.
• Playback can be carried out at the same time as recording.
• Alarm recording tracks movements of suspicious individuals.
• Timer recording lets you record different sessions each day.
• Pre-alarm recording records the images immediately before an
alarm.
• Audio recording and playback is also possible.
• Has a built-in motion detector function that can trigger alarm
recording when movement is detected.
• Recorded images can be copied using CompactFlash cards.
• Includes a variety of search functions.
Alarm searching using an alarm event list or thumbnail alarm
images
Time and date searches based on recording date and time
Motion sensor detecting by searching for the movement of a
suspicious individual
• A zoom function allows images being monitored or played back to
be enlarged for display.
• Images can be captured by field or by frame.
• The image quality mode can be selected from five modes for both
field and frame.
• Three levels of security lock are available.
• A PCMCIA-compatible network card can be used to carry out
network control.
• Includes an RS-232C interface for computer control.
• Connection to a system controller (sold separately) is possible
using an RS-485 interface.
• A PCMCIA-compatible SCSI card can be used for backups to
DDS (DAT) drives.
Setting-up environment
Leave a space of at least 5 cm between the digital video recorder
and other nearby objects.
Ventilation holes are located at both sides and on the base of the
digital video recorder. Do not allow these ventilation holes to be
covered when setting up the recorder.
Furthermore, avoid using the digital video recorder in places with
poor ventilation.
ACCESSORIES
Power cord
Ferrite core
Fixer power cord tie
Hard disk protection
If any hard disk format errors are found when the power is
turned on, the whole hard disk is checked automatically. If any
further problems are found with the hard disk, the POWER
indicator flashes. Please contact the place of purchase if you
need to reformat the hard disk or make backups of any
images. The hard disk is very sensitive to dust, vibration and
shocks, and it should not be used in places near sources of
magnetic fields. Be sure to observe the following points in
order to prevent any loss of data.
• Do not subject the digital video recorder to shocks.
• Do not use the digital video recorder in places where it will
be subjected to vibration or places which are unstable.
• Do not disconnect the power cord while recording or
playback is in progress.
• Do not use in places which are subject to rapid changes in
temperature (changes of around 10°C in an hour).
• If the digital video recorder is moved to a place with a
large difference in temperature or a high level of humidity,
condensation may form. If the digital video recorder is
used with condensation inside it, operating problems may
occur.
• Do not install the digital video recorder in places which are
constantly vibrating, such as vehicles or trains.
The hard disk and cooling fan are
consumables.
• These parts should generally be replaced after 2 years of
use (for the hard disk) or 3 years of use (for the cooling
fan) at normal temperatures of 25°C. These periods of
time are intended as guides only, and are not a guarantee
of product performance.
For important recordings
• Always check whether a recording has been recorded
properly.
• In case a recording was not recorded properly with this
unit because of faulty connections with other equipment or
a correct playback is not possible, any claims for
compensation will be declined.
• For important recordings, it is recommended to make a
periodical backup copy for protection against loss from any
malfunction or accident.
4
English
1 POWER indicator
Illuminates when the power cord plug is inserted into a wall outlet.
Flashes when there is a problem with the hard disk or fan.
2 FULL indicator
Flashes when the remaining space in the normal recording area
of the hard disk drops to 1%*. (* This can be changed using the
menu settings.)
3 ALARM FULL indicator
Flashes when the remaining space in the alarm recording area of
the hard disk drops to 1%*. (* This can be changed using the
menu settings.)
4 LOCK indicator
Illuminates when the security lock is engaged and operations are
locked.
If a button is pressed while the lock is engaged, the buzzer
sounds and the indicator illuminates.
5 ALARM indicator
Illuminates during pre-alarm recording.
Flashes during alarm recording.
6 MENU button and indicator
Used to display the menu screens (setting screens).
7 ZOOM button and indicator
Used to display the zoom screen during monitoring and playback.
The indicator illuminates when the zoom screen is displayed.
This does not operate when a multiplexer is connected digitally in
series.
8 CHANNEL button and indicator
If the digital video recorder is connected to a Sanyo multiplexer
that allows decoding of channel information (camera numbers),
channels can be specified so that only those channels are played
back. The indicator illuminates during playback. The CHANNEL
button can only be used during still mode.
9 REC/STOP button and indicator
Use to start normal recording.
The indicator illuminates during recording.
If the button is pressed for 2 seconds or more during recording,
recording stops and the indicator switches off.
F EXIT/OSD button and indicator
• When a menu screen is displayed
The main menu or sub-menu is exited.
• During recording or playback
When the button is pressed during recording or playback,
superimposed information such as time and date and alarm
status changes in the following order:
Displayed at top-left → Displayed at bottom-left → Displayed
at top-right → Displayed at bottom-right → Off.
The indicator illuminates while information is displayed.
G SEARCH FRAME/FIELD button and indicator
• During recording or when stopped
When the button is pressed during recording or when the
digital video recorder is stopped, the indicator illuminates and
search playback is possible.
• During playback
When the button is pressed during playback, the indicator
illuminates and the mode change to frame/field playback
mode.
H COPY button and indicator
Used to copy images to the archive area of the hard disk or to a
CompactFlash card or microdrive.
The indicator illuminates during copying.
I TIMER button and indicator
When the button is pressed when recording is stopped, the digital
video recorder switches to timer recording standby mode, and
when the setting time is reached, timer recording starts.
J PLAY/STOP button and indicator
When the button is pressed, the indicator illuminates and
playback of images in the normal recording area starts.
If pressed during playback, playback stops.
K STILL button and indicator
When this button is pressed during playback, the indicator
illuminates and playback pauses. If it is pressed again, playback
resumes.
L SHUTTLE HOLD button and indicator
This locks the speed for playback and frame advance.
The indicator illuminates while locked.
M ALARM buttons (û ALARM ù)
When these buttons are pressed during playback, playback skips
to the previous or next alarm recording.
N Jog (inner) and shuttle (outer) dials
• During playback
The jog dial changes the playback speed.
The shuttle dial fast-forwards and rewinds.
• Menu screens
The jog dial moves the cursor and changes settings.
The shuttle dial accepts settings.
O CompactFlash card slot
Insert a CompactFlash card or microdrive here.
P MENU RESET button
Reinitializes menu settings.
POWER
FULL
ALARM FULL
LOCK
ALARM
MENU
EXIT/OSD
PLAY/STOP
ZOOM
SEARCH
FRAME/FIELD
STILL
CHANNEL
COPY
SHUTTLE HOLD
REC/STOP
TIMER
ALARM
JOG
SHUTTLE
E
N
T
E
R
C
L
E
A
R
1
2
3
4
5
7
8
6 FGJK
N
9 IH M L
O
P
English
5
1 PC card slot
Connect a network card or SCSI card (sold separately) here.
2 MIC IN terminal
3 AUDIO IN terminal
4 AUDIO OUT terminal
5 S-VIDEO IN terminal
6 S-VIDEO LOOP OUT terminal
7 S-VIDEO OUT terminal
8 VIDEO IN terminal
Images being input to the S-VIDEO IN terminal take priority.
9 VIDEO LOOP OUT terminal
F VIDEO OUT terminal
G DIGITAL VIDEO IN terminal
H DIGITAL VIDEO OUT terminal
I DIGITAL VIDEO SUB IN terminal
J DIGITAL VIDEO SUB OUT terminal
K RS-232C terminal
L ALL RESET button
M RS-485 termination switch
N Control connector
Pin
Signal
C
Ground
A
RS-485 connector*
B
RS-485 connector*
C
Ground
REMOTE
Remote control input
C
Ground
NC
Spare
NC
Spare
C
Ground
SW OUT
Switching output
C
Ground
* Used for twisted-pair cable connection.
O Alarm connector
Pin
Signal
C
Ground
ALARM IN
Alarm input
ALARM RESET
Alarm reset input
ALARM OUT
Alarm output
NON REC OUT
Non-rec output
C
Ground
CLOCK ADJUST IN
Clock sync input (See page 41.)
CLOCK ADJUST OUT
Clock sync output (See page 41.)
WARNING OUT
Hard disk error warning output
FULL
Hard disk space warning output
ALARM OUT
Alarm recording area space warning
output
P AC power socket (AC IN~)
Securely insert the accessory power cord here.
Q Power cord holder
Secure the power cord to the holder using the accessory cord tie
as shown in the illustration.
AC IN
RS232C
ALARM
FULL
SW OUT
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
C
NC
C
NON REC
OUT
ALARM
IN
ALARM
RESET
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SUB OUT
OUT
DIGITAL
VIDEO
AUDIO
S-VIDEO
SUB IN
IN
OUT
OUT
LOOP OUT
LOOP OUT
IN
OUT
IN
MIC
IN
IN
EJECT
PC Card SLOT
2
3 4
O
P
N
M
L
K
J
I
H
G
F
9
8
7
6
5
1
Q
6
English
Be sure to carefully read the Instruction Manuals for all equipment being connected to the digital video recorder.
If the connections are incorrect, smoke or operating malfunctions may result.
Basic connections
System control connections
Use a twisted-pair cable (sold separately) to connect a system
controller to control terminals A, B and C (ground) of the digital video
recorder. Connect signal A to signal A and signal B to signal B.
Connecting a remote control circuit
If a remote control circuit is constructed as shown in the illustration
and connected to the REMOTE control input terminals of the control
connector, the digital video recorder can be operated by remote
control.
AC IN
RS232C
ALARM
FULL
SW OUT
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
C
NC
C
NON REC
OUT
ALARM
IN
ALARM
RESET
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SUB OUT
OUT
DIGITAL
VIDEO
AUDIO
S-VIDEO
SUB IN
IN
OUT
OUT
LOOP OUT
LOOP OUT
IN
OUT
IN
MIC
IN
IN
EJECT
PC Card SLOT
AUDIO
IN
Microphone input
Video camera (sold separately)
TV monitor
(sold separately)
VIDEO IN
connector
TV monitor
(sold separately)
S-VIDEO IN
connector
Computer
32C
SW OUT
C
C
NC
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
Push and insert cables
Twisted-pair cable
Ground
To signal A
To signal B
System controller (sold separately)
RS-485 connector
SW OUT
C
C
NC
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SW 1: REC STOP
SW 2: PLAY STOP
SW 3: PAUSE
SW 4: SEARCH
SW 5: CHANNEL
SW 6: PLAY
SW 7: REC
SW 8: MENU
SW 9 : EXIT/OSD
SW 14 : ZOOM
SW 15 : COPY
SW 16 : TIMER
220Ω
220Ω
300Ω
360Ω
470Ω
680Ω
820Ω
1.2kΩ
1.8kΩ
2.2kΩ
3.3kΩ
4.7kΩ
7.5kΩ
13kΩ
27kΩ
68kΩ
SW: Switch
The remote control cable should
be no more than 5 m long.
Note:
SW 10 : JOG j
SW 11 : JOG l
SW 12 : SHUTTLE c
SW 13 : SHUTTLE d
English
7
Digital multiplexer connections
Connect to a multiplexer (MPX-CD163P or CD93P) that allows digital connections.
Digital series connections
Up to three digital video recorders can be connected digitally for recording images in series.
Note: When digital video recorders are connected digitally in series, the digital input and output terminals can be used to transmit video signals,
control signals and switching signals. However audio signals cannot be transmitted in the same way, so if audio signals also need to be
recorded, connect the audio input terminals via an amplifier as shown in the connection diagram.
AC IN
RS232C
ALARM
FULL
SW OUT
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
C
NC
C
NON REC
OUT
ALARM
IN
ALARM
RESET
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SUB OUT
OUT
DIGITAL
VIDEO
AUDIO
S-VIDEO
SUB IN
IN
OUT
OUT
LOOP OUT
LOOP OUT
IN
OUT
IN
MIC
IN
IN
EJECT
PC Card SLOT
C
IN
S-VIDEO
6
2
10
14
5
1
9
13
7
3
11
15
8
4
12
16
TV monitor (sold separately)
Multiplexer (sold separately)
Alarm input
Alarm output
DIGITAL IN
DIGITAL OUT
Ground (C)
✱ Cable (straight-type CAT-5, 3 m or less)
AC IN
RS232C
ALARM
FULL
SW OUT
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
C
NC
C
NON REC
OUT
ALARM
IN
ALARM
RESET
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SUB OUT
OUT
DIGITAL
VIDEO
AUDIO
S-VIDEO
SUB IN
IN
OUT
OUT
LOOP OUT
LOOP OUT
IN
OUT
IN
MIC
IN
IN
EJECT
PC Card SLOT
AC IN
RS232C
ALARM
FULL
SW OUT
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
C
NC
C
NON REC
OUT
ALARM
IN
ALARM
RESET
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SUB OUT
OUT
DIGITAL
VIDEO
AUDIO
S-VIDEO
SUB IN
IN
OUT
OUT
LOOP OUT
LOOP OUT
IN
OUT
IN
MIC
IN
IN
EJECT
PC Card SLOT
AC IN
RS232C
ALARM
FULL
SW OUT
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
C
NC
C
NON REC
OUT
ALARM
IN
ALARM
RESET
NC
C
C
OFF
ALL
RESET
RS485
TERMINATE
B
A
ON
C
RS485
REMOTE
SUB OUT
OUT
DIGITAL
VIDEO
AUDIO
S-VIDEO
SUB IN
IN
OUT
OUT
LOOP OUT
LOOP OUT
IN
OUT
IN
MIC
IN
IN
EJECT
PC Card SLOT
Multiplexer (sold separately)
Digital video recorder (main)
Digital video recorder (sub 1)
Digital video recorder (sub 2)
6
2
10
14
5
1
9
13
7
3
11
15
8
4
12
16
TV monitor
(sold separately)
Amplifier
(sold separately)
Amplifier
(sold separately)
8
English
BUILT-IN HARD DISK
Hard disk
Recording areas
The recording areas on the hard disk (normal recording area: 80%,
alarm recording area: 19%, archive area: 1%) are established
automatically when the power for the digital video recorder is turned
on. Images are recorded in the normal recording area when the
REC/STOP button is pressed, and they are recorded in the alarm
recording area when an alarm occurs. This is called the default
condition, and the following detailed settings can be confirmed in the
sections on “RECORDING IMAGES IN THE NORMAL RECORDING
AREA” and “RECORDING IMAGES IN THE ALARM RECORDING
AREA” which are explained later. Furthermore, settings such as the
recording areas and picture quality can be changed using the menu
screens.
A Normal recording area
• When the REC/STOP button is pressed while monitoring is in
progress, images are recorded in the normal recording area.
• When start and end times are entered for each day of the week
and are then enabled, timer recording is automatically carried out
in the normal recording area between the times that have been
set.
B Alarm recording area
ALARM REC MODE SET menu settings are required.
• Alarm recording is enabled when ALARM RECORDING is set.
When a suspicious person is detected by the switch or motion
sensor that is connected to the alarm input terminal, an alarm is
recorded in the alarm recording area.
• Pre-alarm recording is enabled when PRE-ALARM RECORDING
is set. Pre-alarm recording repeatedly records the same images
as for normal recording in the alarm recording area, and
overwrites these images after the set time interval, until an alarm
is detected. When pre-alarm recording is set, the image
immediately before an alarm occurred can be recorded.
C Archive area
This is the area for copying important images from the normal
recording area and the alarm recording area. The size of the archive
area can be set to a maximum of 12 GB (15% of total capacity when
using an 80-GB hard disk) by changing the size of the normal
recording area or the alarm recording area.
Archive area
C
Normal recording area
Normal recording area
Normal recording area
A
Alarm
Alarm
recording
area
Alarm
recording
area
B
Hard disk recording areas
1%
1%
80%
80%
19%
19%
1%
80%
19%
Menu screen (initial setting)
This can be displayed by pressing the MENU button.
1 Picture quality: ENHANCED
Picture quality can be selected from five options.
The recording speed changes in accordance with the picture
quality selected.
2 Recording method: Can be set to FRAME or FIELD.
The recording speed changes in accordance with the method
selected.
3 Audio recording: Can be set to ON or OFF.
4 Recording speed: Shows the recording interval and the
recording time.
Refer to the recording speed table for further details.
5 Alarm recording setting: Can be set to ON or OFF.
When alarm recordings are to be made, select a setting such
as MODE1 for the OFF setting. The recording speed and
alarm duration will be displayed
A Setting screen for normal recording area picture quality,
recording speed, etc.
B Setting screen for alarm recording area picture quality,
recording speed, etc.
TOTAL CAPACITY : 80GB
NORMAL RECORDING AREA : 80 %
AREA FULL RESET ->
ALARM RECORDING AREA : 19 %
AREA FULL RESET ->
ARCHIVE AREA : 1 %
AREA FULL RESET ->
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
A
B
A
B
C
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
REC CYCLE : 0.12SEC ( 65H)
1
23
4
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
1
23
54
English
9
BUILT-IN HARD DISK
Recording speed tables
These recording speed tables show the recording times for various picture quality and frame/field settings when recording in the normal
recording area of the hard disk (80 GB). They do not include audio recording settings.
The setting times for the normal recording area and the alarm recording area represent the picture quality values given in the recording speed
tables, multiplied by the percentages for the normal recording area and alarm recording area that have been set using the recording area setting
menu commands.
When recording with an 80-GB hard disk at 100% capacity
Field recording
Recording
Rate
(field/sec)
Recording
Cycle (SEC)
PICTURE QUALITY
BASIC
NORMAL
ENHANCED
FINE
SUPER FINE
15 kB
22 kB
30 kB
42 kB
56 kB
50.00
0.02
25H
18H
13H
9H
7H
25.00
0.04
51H
36H
27H
19H
14H
16.67
0.06
76H
54H
40H
29H
22H
12.50
0.08
102H
72H
54H
39H
29H
8.33
0.12
153H
108H
81H
59H
44H
6.25
0.16
204H
144H
108H
78H
59H
5.00
0.20
255H
180H
135H
98H
74H
4.17
0.24
306H
217H
162H
118H
89H
3.57
0.28
357H
253H
189H
138H
104H
3.13
0.32
408H
289H
217H
157H
119H
2.78
0.36
459H
325H
244H
177H
134H
2.50
0.40
510H
361H
271H
197H
149H
2.27
0.44
561H
397H
298H
217H
164H
1.92
0.52
663H
470H
352H
256H
194H
1.67
0.60
765H
542H
406H
295H
224H
1.47
0.68
868H
614H
461H
335H
254H
1.32
0.76
970H
687H
515H
374H
284H
1.19
0.84
1072H
759H
569H
414H
314H
1.09
0.92
1174H
831H
623H
453H
344H
1.00
1
1276H
904H
678H
493H
374H
0.50
2
2553H
1808H
1356H
986H
748H
0.33
3
3829H
2712H
2034H
1479H
1122H
0.25
4
5106H
3616H
2712H
1972H
1496H
0.20
5
6382H
4521H
3390H
2466H
1870H
0.10
10
12765H
9042H
6781H
4932H
3741H
0.05
20
25531H
18084H
13563H
9864H
7483H
0.03
30
38296H
27126H
20345H
14796H
11224H
Frame recording
Recording
Rate
(frame/sec)
Recording
Cycle (SEC)
PICTURE QUALITY
BASIC
NORMAL
ENHANCED
FINE
SUPER FINE
15 kB
22 kB
30 kB
42 kB
56 kB
25.00
0.04
25H
18H
13H
9H
7H
12.50
0.08
51H
36H
27H
19H
14H
8.33
0.12
76H
54H
40H
29H
22H
6.25
0.16
102H
72H
54H
39H
29H
4.17
0.24
153H
108H
81H
59H
44H
3.13
0.32
204H
144H
108H
78H
59H
2.50
0.40
255H
180H
135H
98H
74H
2.08
0.48
306H
217H
162H
118H
89H
1.79
0.56
357H
253H
189H
138H
104H
1.56
0.64
408H
289H
217H
157H
119H
1.39
0.72
459H
325H
244H
177H
134H
1.25
0.80
510H
361H
271H
197H
149H
1.14
0.88
561H
397H
298H
217H
164H
0.96
1.04
663H
470H
352H
256H
194H
0.83
1.20
765H
542H
406H
295H
224H
0.74
1.36
868H
614H
461H
335H
254H
0.66
1.52
970H
687H
515H
374H
284H
0.60
1.68
1072H
759H
569H
414H
314H
0.54
1.84
1174H
831H
623H
453H
344H
0.50
2
1276H
904H
678H
493H
374H
0.25
4
2553H
1808H
1356H
986H
748H
0.17
6
3829H
2712H
2034H
1479H
1122H
0.13
8
5106H
3616H
2712H
1972H
1496H
0.10
10
6382H
4521H
3390H
2466H
1870H
0.05
20
12765H
9042H
6781H
4932H
3741H
0.03
40
25531H
18084H
13563H
9864H
7483H
0.02
60
38296H
27126H
20345H
14796H
11224H
The tables below are recording speed tables provided for reference if the total capacity of the hard disk has been increased to 160 GB. Contact
the place of purchase for details on increasing the capacity of the hard disk.
When recording with a 160-GB hard disk at 100% capacity
Field recording
Recording
Rate
(field/sec)
Recording
Cycle (SEC)
PICTURE QUALITY
BASIC
NORMAL
ENHANCED
FINE
SUPER FINE
15 kB
22 kB
30 kB
42 kB
56 kB
50.00
0.02
51H
36H
27H
19H
14H
25.00
0.04
102H
72H
54H
39H
29H
16.67
0.06
153H
108H
81H
59H
44H
12.50
0.08
204H
144H
108H
78H
59H
8.33
0.12
306H
217H
162H
118H
89H
6.25
0.16
408H
289H
217H
157H
119H
5.00
0.20
510H
361H
271H
197H
149H
4.17
0.24
612H
434H
325H
236H
179H
3.57
0.28
714H
506H
379H
276H
209H
3.13
0.32
816H
578H
434H
315H
239H
2.78
0.36
919H
651H
488H
355H
269H
2.50
0.40
1021H
723H
542H
394H
299H
2.27
0.44
1123H
795H
596H
434H
329H
1.92
0.52
1327H
940H
705H
512H
389H
1.67
0.60
1531H
1085H
813H
591H
448H
1.47
0.68
1736H
1229H
922H
670H
508H
1.32
0.76
1940H
1374H
1030H
749H
568H
1.19
0.84
2144H
1519H
1139H
828H
628H
1.09
0.92
2348H
1663H
1247H
907H
688H
1.00
1
2553H
1808H
1356H
986H
748H
0.50
2
5106H
3616H
2712H
1972H
1496H
0.33
3
7659H
5425H
4069H
2959H
2244H
0.25
4
10212H
7233H
5425H
3945H
2993H
0.20
5
12765H
9042H
6781H
4932H
3741H
0.10
10
25531H
18084H
13563H
9864H
7483H
0.05
20
51062H
36168H
27126H
19728H
14966H
0.03
30
76593H
54253H
40690H
29592H
22449H
Frame recording
Recording
Rate
(frame/sec)
Recording
Cycle (SEC)
PICTURE QUALITY
BASIC
NORMAL
ENHANCED
FINE
SUPER FINE
15 kB
22 kB
30 kB
42 kB
56 kB
25.00
0.04
51H
36H
27H
19H
14H
12.50
0.08
102H
72H
54H
39H
29H
8.33
0.12
153H
108H
81H
59H
44H
6.25
0.16
204H
144H
108H
78H
59H
4.17
0.24
306H
217H
162H
118H
89H
3.13
0.32
408H
289H
217H
157H
119H
2.50
0.40
510H
361H
271H
197H
149H
2.08
0.48
612H
434H
325H
236H
179H
1.79
0.56
714H
506H
379H
276H
209H
1.56
0.64
816H
578H
434H
315H
239H
1.39
0.72
919H
651H
488H
355H
269H
1.25
0.80
1021H
723H
542H
394H
299H
1.14
0.88
1123H
795H
596H
434H
329H
0.96
1.04
1327H
940H
705H
512H
389H
0.83
1.20
1531H
1085H
813H
591H
448H
0.74
1.36
1736H
1229H
922H
670H
508H
0.66
1.52
1940H
1374H
1030H
749H
568H
0.60
1.68
2144H
1519H
1139H
828H
628H
0.54
1.84
2348H
1663H
1247H
907H
688H
0.50
2
2553H
1808H
1356H
986H
748H
0.25
4
5106H
3616H
2712H
1972H
1496H
0.17
6
7659H
5425H
4069H
2959H
2244H
0.13
8
10212H
7233H
5425H
3945H
2993H
0.10
10
12765H
9042H
6781H
4932H
3741H
0.05
20
25531H
18084H
13563H
9864H
7483H
0.03
40
51062H
36168H
27126H
19728H
14966H
0.02
60
76593H
54253H
40690H
29592H
22449H
Reference: 24H = 1 day, 168H = 1 week, 720H = 1 month, 8760H = 1 year
10
English
BUILT-IN HARD DISK
Operating display
When the power for the digital video recorder is turned on, the operating display appears in the upper-left corner of the monitor screen. This
operating display shows information which is essential for operation, such as the date, time, picture quality and recording speed.
1 Camera number display
Connect the digital video recorder to a multiplexer that is capable
of decoding Sanyo’s channel information (camera number) and
press the CHANNEL button. The number of the specified camera
appear in the display during playback.
2 Date display
When the digital video recorder is first turned on, the date
appears as 01-01-01 (day, month, year). Make sure that you use
the menus to set the correct date.
3 Operating symbol display
These symbols appear during recording and playback.
a
: Recording
e : Fast forward
c
: Playback
f : Rewind
d
: Reverse playback
h
: Stopped
hc : Slow playback
dh : Slow reverse playback
Note: If recording and playback are being carried out at the same
time, the playback symbol (c) appears.
4 Amount of recording area remaining
If overwriting has been disabled (OVERWRITE: OFF) in the
normal recording area or alarm recording area, the amount of
space remaining appears as a percentage. You can change the
amount of recording area remaining using the RECORDING
CONDITIONS SET menu item. (See page 45.)
5 Alarm display and alarm number display
When an alarm setting is made using the ALARM REC MODE
SET menu item, The following display appears in the alarm
display.
However, the PRE display appears when pre-alarm recording has
been set. When an alarm occurs, the PRE is replaced by ALARM
and the number of alarms also appears. The alarm display shows
the cumulative number of alarms.
• If ALARM RECORDING is set: ALARM appears.
ALARM flashes while an alarm is being recorded.
• If PRE-ALARM RECORDING is set: PRE appears.
• When playing images from the archive area: ARCHIV appears.
6 Time display
When the digital video recorder is first turned on, the time
appears as 00:00:00, and the time starts counting after the date
has been set. The digital video recorder uses the date and time to
control recording and playback, so if the date and time have not
been set, the correct images cannot be retrieved. Make sure that
you use the menus to set the correct time.
7 Picture quality display
This shows the picture quality for images that are recorded on the
hard disk. The default setting is EN (Enhanced). The display
changes when the picture quality is changed using the NORMAL
REC MODE SET menu item.
• BA: Basic
• NO: Normal
• EN: Enhanced
• FI: Fine
• SF: Super Fine
8 Recording speed display
This displays the recording speed for images that are recorded
on the hard disk. The default setting is 0.12 SEC (during field
recording). The display changes when the picture quality and
recording method are changed using the NORMAL REC MODE
SET menu item.
01-01-01 ALARM 0000
00:00:00 EN 0.12SEC
4CH 100%
01-01-01 ALARM 0000
00:00:00 EN 0.12SEC
1
6
2
3
4 5
7
8
Note: During recording with this unit, playing back,
copying and transferring pictures is possible.
However, because of the recording priority the
response of the other operations becomes slower.
English
11
RECORDING IMAGES IN THE
NORMAL RECORDING AREA
Normal recording
Images can be recorded in the normal recording area while they are being monitored.
Insert the power cord into a wall outlet and turn on the
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
button, the date and time appear in the operating display. (See page 40.)
Press the REC/STOP button.
“a” appears in the operating display and the images being monitored are
recorded in the normal recording area. Recording onto the hard disk
proceeds automatically (default setting) according to the following settings.
The settings can be changed between long-period recording and high-quality
recording in five steps. (See page 47.)
• Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
• Picture quality: EN (Enhanced)
• Recording method: Field
• Recording speed: 0.12 seconds (65H)
Note: Playback is possible during recording. When the PLAY/STOP button is
pressed during recording, “c” appears in the operating display and
images are played back from the point where recording began. (See
page 19.)
Press and hold the REC/STOP button for 3 seconds or
more.
The “a” in the operating display disappears and recording stops.
Note: When the remaining area in the normal recording area drops below the
set amount, the FULL indicator on the front panel flashes. If recording
continues under these conditions, the recording area becomes full and
recording stops. In the RECORDING AREA SET settings, carry out the
AREA FULL RESET operation for the normal recording area.
Recording will then be possible from the beginning again. (See page
44.)
POWER
EXIT/OSD
1
Operating display
01-01-01
00:00:00 EN 0.12SEC
MENU
2
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
ENGLISH
01-01-2001 MON 00:00:00
S
S
REC/STOP
3
26-10-01
10:48:38 EN 0.12SEC
26-10-01
11:02:28 EN 0.12SEC
Recording start time
REC/STOP
4
POWER
FULL
ALARM FULL
LOC
Monitored images
are recorded.
12
English
RECORDING IMAGES IN THE NORMAL RECORDING AREA
Timer recording
The monitored images can be recorded automatically by setting start and end times for each day of the week.
Insert the power cord into a wall outlet and turn on the
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
1 Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
button, the date and time appear in the operating display. (See page 40.)
2 Set the timer.
Press the MENU button to display the TIMER SET menu, and then set the
start and end times for timer recording. (See page 48.)
Then press the EXIT/OSD button.
Press the TIMER button.
The TIMER indicator illuminates and the digital video recorder switches to
timer recording standby mode.
Note:
• If SET in the TIMER SET menu is not set to “ON”, or if the timer settings
are not made correctly, an alarm will sound when the TIMER button is
pressed.
• The TIMER indicator illuminates when the timer setting has been made
correctly.
• When the timer setting time is reached, the TIMER indicator and the REC
indicator illuminate and timer recording starts.
• If you press the TIMER button during timer recording, the TIMER indicator
and the REC indicator switch off and timer recording stops.
POWER
EXIT/OSD
1
Operating display
01-01-01
00:00:00 EN 0.12SEC
MENU
2
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
ENGLISH
01-01-2001 MON 00:00:00
S
S
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
WEEK START STOP REC CYCLE SET
SUN --:-- --:-- 0.12SEC ( 65H) OFF
MON --:-- --:-- 0.12SEC ( 65H) OFF
TUE --:-- --:-- 0.12SEC ( 65H) OFF
WED --:-- --:-- 0.12SEC ( 65H) OFF
TIMER
3
10-05-01
17:30:25 EN 0.12SEC
English
13
Timer recording starts when the timer setting time is
reached.
“a” appears in the operating display and the images being monitored are
recorded in the normal recording area. Recording onto the hard disk
proceeds automatically (default setting) according to the following settings.
The settings can be changed between long-period recording and high-quality
recording in five steps. (See page 47.)
• Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
• Picture quality: EN (Enhanced)
• Recording method: Field
• Recording speed: 0.12 seconds (65H)
Note: Playback is possible during recording. When the PLAY/STOP button is
pressed during recording, c appears in the operating display and
images are played back from the point where recording began. (See
page 19.)
Timer recording stops when the set end time is reached.
The TIMER indicator swithes off and the recording symbol (a) disappears
from the operating display and recording stops.
Note:
• Press the TIMER button to stop timer recording. Timer recording then
stops.
• When the remaining area in the normal recording area drops below the
set amount, the FULL indicator on the front panel flashes. If recording
continues under these conditions, the recording area becomes full and
recording stops. In the RECORDING AREA SET settings, carry out the
AREA FULL RESET operation for the normal recording area.
Recording will then be possible from the beginning again. (See page 44.)
4
10-05-01
19:30:00 EN 0.12SEC
TIMER
5
POWER
FULL
ALARM FULL
LOC
14
English
RECORDING IMAGES IN THE
ALARM RECORDING AREA
Alarm recording
Insert the power cord into a wall outlet and turn on the
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
1 Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
button, the date and time appear in the operating display. (See page 40.)
2 Set alarm recording.
• Press the MENU button to display the ALARM REC MODE SET menu
from the MAIN MENU screen. Then change the ALARM RECORDING
setting to the desired alarm recording setting (MODE1, 2, 3 or 4) and
change the ALARM TRIGGER setting. (See page 52 – 54.)
• Press the MENU button, to display the BUZZER SET menu from the
MAIN MENU 2 screen, and change the ALARM setting to “ON”.
(See page 60.)
• Press the EXIT/OSD button to return to the normal screen.
Suspicious person detection
When an alarm occurs, “ALARM” appears in the operating display, the
ALARM indicator flashes and alarm recording (a symbol) starts. Alarm
images are recorded in the alarm recording area. Furthermore, the number of
alarms in the operating display is increased by one each time an alarm
occurs.
Note: Normal recording and timer recording stop when an alarm occurs
during normal recording or timer recording.
Ending alarm recording
Recording ends after the end of the alarm duration period (default setting: 1
sec). The “a” and ALARM displays stop flashing and recording stops.
Note: When the remaining area in the alarm recording area reaches 1%, the
ALARM FULL indicator on the front panel flashes. If recording is
continued under these conditions, the recording area is filled and the
recording stops. In the RECORDING AREA SET settings, carry out the
AREA FULL RESET operation for the alarm recording area.
Overwriting will be canceled and recording will be possible from the
beginning again. (See page 44.)
POWER
EXIT/OSD
1
Operating display
01-01-01
00:00:00 EN 0.12SEC
MENU
2
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
ENGLISH
01-01-2001 MON 00:00:00
S
S
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : MODE1
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
ALARM
3
10-05-01 ALARM 0001
18:10:25 EN 0.12SEC
The number of
alarms is counted.
4
POWER
FULL
ALARM FULL
LOC
Alarm images are
recorded
English
15
RECORDING IMAGES IN THE ALARM
RECORDING AREA
Pre-alarm recording
Insert the power cord into a wall outlet and turn on the
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
button, the date and time appear in the operating display. (See page 40.)
Set pre-alarm recording.
Press the MENU button to display the ALARM REC MODE SET menu. Set
ALARM RECORDING to the desired alarm recording setting (example:
MODE1). The *** setting for PRE-ALARM RECORDING will be set to
“OFF”, so change it to “ON”. (See page 54.)
Press the EXIT/OSD button to return to the normal screen. “PRE” appears in
the operating display, the ALARM indicator illuminates and pre-alarm
recording starts (the a mark does not appear).
The same monitored image as in the normal recording area is recorded
repeatedly in the alarm recording area.
Recording onto the hard disk proceeds automatically (default setting)
according to the following settings. The settings can be changed between
long-period recording and high-quality recording in five steps. (See page 47.)
• Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
• Picture quality: EN (Enhanced)
• Recording method: Field
• Recording speed: 0.12 seconds (65H)
POWER
EXIT/OSD
1
Operating display
01-01-01
00:00:00 EN 0.12SEC
MENU
2
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
ENGLISH
01-01-2001 MON 00:00:00
S
S
REC/STOP
ALARM
3
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : MODE1
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
10-05-01 PRE 0000
18:10:25 EN 0.12SEC
Pre-alarm images
are recorded
Monitored images
are recorded
16
English
RECORDING IMAGES IN THE ALARM RECORDING AREA
When an alarm is received, pre-alarm recording stops
automatically and the alarm images are recorded.
The “PRE” disappears from the operating display, “ALARM” flashes and the
ALARM indicator flashes.
Note: When the remaining area in the alarm recording area reaches 1%, the
ALARM FULL indicator on the front panel flashes. If recording is
continued under these conditions, the recording area is filled and the
recording stops.
In the RECORDING AREA SET settings, carry out the AREA FULL
RESET operation for the normal recording area.
Recording will then be possible from the beginning again. (See page
44.)
ALARM
4
10-06-01 ALARM 0000
09:30:15 EN 0.12SEC
POWER
FULL
ALARM FULL
LOC
English
17
PLAYING BACK IMAGES RECORDED IN
THE NORMAL RECORDING AREA
The digital video recorder can play back recorded images in the normal recording area (normal recording, timer recording).
Playback operations
Normal playback
• When playing back recordings for the first time:
The recorded images will be played back from the beginning.
• When playing back for the second or subsequent time:
Playback will start from the point where the last playback session ended.
(Starting point for
first playback)
Ending point
(Starting point for
second playback)
Ending point
(Starting point for
third playback)
Ending point
PLAY/STOP
SEARCH
ALARM
FRAME/FIELD
STILL
ZOOM
SHUTTLE HOLD
SHUTTLE HOLD
b Skipping to the previous or next alarm
(See page 24.)
b Switching between frame and field
(See page 22.)
b Still image
(See page 21.)
b Zooming images (See page 20.)
b Playback
(See page 19.)
b Frame advance
(forward/reverse)
(See page 21.)
b Slow playback
(See page 19.)
Normal recording area
Fast forward/fast rewind playback
(See page 19.)
Locking speed for
fast forward/rewind
playback
(See page 19.)
Releasing speed
lock
18
English
PLAYING BACK IMAGES RECORDED IN THE NORMAL
RECORDING AREA
Playback
Press the PLAY/STOP button.
c appears in the operating display and the images recorded in the normal
recording area are played back.
Note:
• Image playback starts from the point (time) that the recording started.
If there is no starting position, or if a reset has been made, the oldest
recorded image is played back.
• When playback is finished, playback mode is automatically paused.
The pause (h) symbol appears in the operating display and the STILL
indicator illuminates.
• If playback has been carried out at least once, playback will start from the
position where the last playback session ended.
Press the PLAY/STOP button again.
Playback stops.
Note: If playback is started just as recording is being carried out, recording
will have priority, so that the playback images may be paused
momentarily.
Fast forward/rewind playback
Turn the shuttle dial clockwise (or counterclockwise)
during playback.
When the shuttle dial is turned clockwise, e appears in the operating
display and fast forward playback starts. If it is turned counterclockwise, f
appears in the operating display and rewind playback starts.
When you release the shuttle dial, normal playback resumes.
PLAY/STOP
1
26-10-01
11:02:50 EN 0.12SEC
PLAY/STOP
2
20-11-01
04:00:00 EN 0.12SEC
1
17-11-01
02:38:00 EN 0.12SEC
2
SHUTTLE HOLD
Changing the playback speed
(Fast forward/slow playback)
1 Turn the jog dial clockwise.
Fast forward playback starts and e appears in the operating display.
2 Turn the jog dial counterclockwise.
Slow playback starts and hc appears in the operating display.
3 Return to normal playback.
Turn the jog dial clockwise. c appears in the operating display.
(Rewind/slow playback)
1 Turn the shuttle dial counterclockwise (fix at rewind).
d will be displayed, so press the SHUTTLE HOLD button. The SHUTTLE HOLD indicator will illuminate and the
rewind playback speed will be fixed at the current speed.
2 Turn the jog dial counterclockwise.
The speed becomes faster than for normal rewind playback, and f appears in the operating display.
3 Turn the jog dial clockwise.
Slow rewind playback starts and dh appears in the operating display.
4 Return to normal playback.
Turn the jog dial counterclockwise. c appears in the operating display.
English
19
PLAYING BACK IMAGES RECORDED IN THE NORMAL
RECORDING AREA
Zooming the image during playback
Press the ZOOM button during playback.
The zoom frame (blue) appears in the center of the screen.
Move the zoom frame to the position where the image is
to be enlarged.
• Turn the jog dial clockwise to move the zoom frame to the right.
Turn it counterclockwise to move the zoom frame to the left.
• Turn the shuttle dial clockwise to change to vertical movement. Then turn
the jog dial clockwise to move the zoom frame upward and turn it
counterclockwise to move the zoom frame downward.
Move the zoom frame to the position to be enlarged.
Turn the shuttle dial.
The area inside the zoom frame is enlarged (2x).
Press the ZOOM button (to cancel zooming).
The image zooming is canceled and normal playback continues.
Note:
• The display cannot be enlarged even while monitoring a camera image.
• The ZOOM button cannot be selected, when a multiplexer is used as a
video input.
• The picture quality becomes coarser when the image is zoomed.
ZOOM
1
2
3
17-11-01
02:36:00 EN 0.12SEC
ZOOM
4
17-11-01
02:36:00 EN 0.12SEC
20
English
PLAYING BACK IMAGES RECORDED IN THE NORMAL
RECORDING AREA
Viewing still images
Press the STILL button during playback.
h appears in the operating display and a still image is displayed.
Press the STILL button once more.
Still mode is canceled.
Frame advance (forward/reverse)
Turn the jog dial clockwise (or counterclockwise) in still
mode.
Turn the jog dial clockwise to advance the still image by one frame (one field).
Turn it counterclockwise to rewind the still image by one frame (one field).
Note: If the jog dial is turned quickly, the frame feed speed also increases.
STILL
1
17-11-01
02:38:00 EN 0.12SEC
STILL
2
17-11-01
02:38:20 EN 0.12SEC
1
17-11-01
02:50:08 EN 0.12SEC
During the following operations the picture may appear
distorted or momentarily frozen. This is normal and not a
malfunction.
• During the continuous playback from the normal and
the alarm recording area, the picture may be distorted
when the recording area is switched.
• When playing back during an alarm recording, during
continuous playback from the normal and alarm
recording area, during normal playback or when using
the fast forward/rewind playback the picture may
appear momentarily frozen.
English
21
PLAYING BACK IMAGES RECORDED IN THE NORMAL
RECORDING AREA
Selecting a camera image channel for playback
When the digital video recorder has been connected to a multiplexer (sold separately) and camera images have been recorded, you can specify
the channel (camera number) for the images recorded and play them back.
Press the CHANNEL button while playback is paused.
The screen for selecting the camera number for cameras connected to the
multiplexer appears.
Use the jog dial to specify the channel (example: camera
4).
Turn the shuttle dial clockwise.
“c” appears in the operating display, and playback of images from the
specified channel starts.
Note:
• If the digital video recorder is not connected to a multiplexer that allows
decoding of channel information (camera numbers), channels can not be
specified for playback.
• When this operation is carried out, only the specified channel is played
back, and so other channels are not displayed.
• When a channel is selected, the multiplexer title information and date
information may not be fully displayed in some cases.
Switching between frame and field playback
Press the SEARCH FRAME/FIELD button while frame
recording images are being played back.
The screen changes between frame and field playback each time the button
is pressed.
Note:
• Switching between frame and field playback is only possible when images
that have been recorded in frame mode are being played back.
• When playing back of frame recording images that contain rapid
movement, instability may occur in the images.
CHANNEL
1
PLEASE SELECT CHANNEL
-- CHANNEL
CHANGE WITH JOG. SET WITH SHUTTLE
2
PLEASE SELECT CHANNEL
4 CHANNEL
CHANGE WITH JOG. SET WITH SHUTTLE
3
CH4
27-10-01
13:38:33 SF 0.03SEC
SEARCH
FRAME/FIELD
1
22
English
SEARCHING FOR RECORDED IMAGES
Images that have been recorded in the alarm recording area and in the archive area can be played back. Furthermore, images can also be
searched for by recording date and time, and you can also search for moving objects that have been detected by a motion sensor during image
playback.
SEARCH
FRAME/FIELD
0109 0108 0107
0106 0105 0104
0103 0102 0101
NO DATE TIME TOTAL ALARM
0108 13-12 11:13 0234
0107 13-12 11:15
0106 13-12 15:19
0105 15-12 10:13
0104 16-12 16:13
0103 16-12 11:13
0102 19-12 14:23
0101 20-12 05:37
MOVE:JOG SELECT:SHUTTLE
SEARCHING FOR RECORDED IMAGES
Alarm search
All alarm recording images in the alarm recording area can be searched for and played back. If pre-alarm images have is recorded, the images
immediately before the alarms can also be played back.
Press the SEARCH FRAME/FIELD button during
recording or when the digital video recorder is stopped.
The SEARCH screen appears.
Use the jog dial to select ALARM SEARCH and then turn
the shuttle dial clockwise.
The ALARM SEARCH screen appears.
1 NO: Alarm number appears.
2 DATE/TIME: The date and time that the alarm was received and the
images were recorded appears.
3 TOTAL ALARM: The total number of alarm images recorded appears.
Use the jog dial to move the cursor in order to select the
images to be played back.
The selected alarm image appears in the preview screen.
Note:
• Up to eight items of alarm information can be displayed on the ALARM
SEARCH screen. When the jog dial is turned, the previous or next alarm
information screen appears.
• To end this search mode, press the SEARCH FRAME/FIELD button.
Turn the shuttle dial clockwise.
The preview image appears in a single-screen display and playback starts.
Note:
• You can also use the shuttle dial or jog dial to carry out operations such
as pausing and fast-forward playback.
• Alarm search starts playback from the image that was recorded at the
instant the alarm occurred, so if you are viewing pre-alarm images, use
the shuttle operations to carry out rewind playback.
Alarm search 2
Press an ALARM skip button during playback.
• If you press the û button, playback skips to the previous alarm image.
• If you press the ù button, playback skips to the next alarm image.
Note: When playing back using alarm search, the playback will pause at the
start and at the end of each alarm recording. Use the ALARM skip
buttons to play back previous and subsequent alarm recordings.
SEARCH
FRAME/FIELD
1
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE
2
NO DATE TIME TOTAL ALARMS
008 13-12 11:13 0010
007 13-12 11:15
006 13-12 15:19
005 15-12 10:13
004 16-12 16:13
003 16-12 11:13
002 19-12 14:23
001 20-12 05:37
MOVE:JOG SELECT:SHUTTLE
1
2
3
3
NO DATE TIME TOTAL ALARM
008 13-12 11:13 0234
007 13-12 11:15
006 13-12 15:19
005 15-12 10:13
004 16-12 16:13
003 16-12 11:13
002 19-12 14:23
001 20-12 05:37
MOVE:JOG SELECT:SHUTTLE
4
18-11-01 ALARM 0004
25:03:12 EN 0.12SEC
ALARM
1
18-11-01 ALARM 0004
25:03:12 EN 0.12SEC
24
English
SEARCHING FOR RECORDED IMAGES
Alarm thumbnail search
Alarm images can be searched for and played back from thumbnails.
All alarm images recorded in the alarm recording area are displayed as thumbnails.
Press the SEARCH FRAME/FIELD button during
recording or when the digital video recorder is stopped.
The SEARCH screen appears.
Use the jog dial to select ALARM THUMBNAIL SEARCH
and then turn the shuttle dial clockwise.
The last nine alarm recording images recorded appear.
The alarm number appears with each alarm recording image, and the alarm
number of the currently-selected alarm image flashes.
Use the jog dial to move the cursor in order to select the
images to be played back.
The alarm number of the currently-selected alarm image flashes.
Note:
• Up to nine items of alarm information including thumbnails can be
displayed. When the jog dial is turned, the previous or next alarm
information screen appears.
• To end this search mode, press the SEARCH FRAME/FIELD button.
Turn the shuttle dial clockwise.
The selected image appears in a single-screen display and playback starts.
Note:
• You can also use the shuttle dial or jog dial to carry out operations such
as pausing and fast-forward playback.
• Only the contents of each alarm can be played back, in the same way as
for alarm searching. Use the ALARM skip buttons to play back previous
and subsequent alarm recordings.
SEARCH
FRAME/FIELD
1
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE
2
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE SEARCH:EXIT
0109 0108 0107
0106 0105 0104
0103 0102 0101
3
0109 0108 0107
0106 0105 0104
0103 0102 0101
4
18-11-01 ALARM 0003
25:02:00 EN 0.12SEC
English
25
SEARCHING FOR RECORDED IMAGES
Time/date search
The recording date and time for images in the normal recording area (normal recording and timer recording images) and in the alarm recording
area of the hard disk can be specified and the images can be played back.
Press the SEARCH FRAME/FIELD button during
recording or when the digital video recorder is stopped.
The SEARCH screen appears.
Use the jog dial to select TIME/DATE SEARCH and then
turn the shuttle dial clockwise.
The TIME/DATE SEARCH screen appears.
1 RECORDING TOP: The date and time of the first recorded image is
displayed.
2 RECORDING END: The date and time of the latest (most recently)
recorded image is displayed.
3 SEARCH: Enter the date and time to be displayed in this area.
4 PREVIEW: A preview image appears.
5 VIEW: The selected image appears on the monitor as a single-screen
image.
Example: To search for 8 pm on 26 October 2001
1 Turn the jog dial clockwise, and then use the jog dial to change “25” to
“26”.
2 Turn the shuttle dial clockwise and select “10”.
3 Turn the shuttle dial clockwise and select “01”.
4 Turn the shuttle dial clockwise, and then use the jog dial to change “08” to
“20”.
5 Turn the shuttle dial clockwise and select “00”. Then turn the shuttle dial.
The cursor moves to PREVIEW.
SEARCH
FRAME/FIELD
1
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE
2
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE
SEARCHING FOR RECORDED IMAGES
Turn the shuttle dial clockwise.
A search display appears while searching is in progress, and then a preview
screen showing the date and time entered appears.
Note: If there are no images that match the time exactly, the image closest to
the selected time range is displayed.
5
Use the jog dial to select VIEW, and then turn the shuttle
dial clockwise.
The preview image is displayed and played back in a single-screen.
Note:
• A single-screen image can be displayed when date and time are entered
and VIEW is selected, even without displaying a preview.
• You can also use the shuttle dial or jog dial to carry out operations such
as pausing and fast-forward playback.
4
RECORDING TOP : 15-12-00 08:00
RECORDING END : 22-12-00 17:00
SEARCH :
DATE TIME
17-11-01 02:36:10
PREVIEW ->
VIEW ->
CHANGE:JOG SET:SHUTTLE
17-11-01
02:36:10 EN 0.12SEC
English
27
SEARCHING FOR RECORDED IMAGES
Archive area search
You can play back images that have been saved (copied) in the archive area.
Press the SEARCH FRAME/FIELD button during
recording or when the digital video recorder is stopped.
The SEARCH screen appears.
Use the jog dial to select ARCHIVE AREA SEARCH and
then turn the shuttle dial clockwise.
The ARCHIVE AREA SEARCH screen appears.
1 NO: The archive number is displayed.
2 DATE: The date of the recorded image is displayed.
3 TIME: The start time of the recorded image is displayed.
4 TOTAL: The total capacity of the archive area is displayed.
5 USED: The recorded part of the archive area is displayed.
Use the jog dial to move the cursor in order to select the
images to be played back.
The selected alarm image appears in the preview screen.
Note:
• Up to eight items of information can be displayed in the ARCHIVE AREA
SEARCH screen.
When the jog dial is turned, the previous or next archive screen appears.
• To end this search mode, press the SEARCH FRAME/FIELD button.
Turn the shuttle dial clockwise.
The selected image appears in a single-screen display and playback starts.
Note:
• A single-screen image can be displayed when the cursor is moved to the
image to be played back and the shuttle dial is turned clockwise, even
without displaying a preview.
• You can also use the shuttle dial or jog dial to carry out operations such
as pausing and fast-forward playback.
SEARCH
FRAME/FIELD
1
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE
2
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE SEARCH:EXIT
NO DATE TIME CAPACITY
0108 13-12 11:13 TOTAL - 1024MB
0107 13-12 11:15 USED - 400MB
0106 13-12 15:19
0105 15-12 10:13
0104 16-12 16:13
0103 16-12 11:13
0102 19-12 14:23
0101 20-12 05:37
MOVE:JOG SELECT:SHUTTLE
1 2 3
45
3
NO DATE TIME CAPACITY
0108 13-12 11:13 TOTAL - 1024MB
0107 13-12 11:15 USED - 400MB
0106 13-12 15:19
0105 15-12 10:13
0104 16-12 16:13
0103 16-12 11:13
0102 19-12 14:23
0101 20-12 05:37
MOVE:JOG SELECT:SHUTTLE
4
18-11-01 ALARM 0004
25:03:12 EN 0.12SEC
28
English
SEARCHING FOR RECORDED IMAGES
Motion detection search
When a motion sensor is set for images recorded in the normal recording area (normal recording and timer recording images) or for images
recorded in the alarm recording area of the hard disk, you can search for images that have changed because of the entry of a suspicious
person, for instance, and play back only those images.
Note:
• If carrying out motion detection searches of multiplexer images, change the setting for MULTIPLEXER in the VIDEO INPUT SET menu to
something other than “NO USE”.
• If the digital video recorder is connected to a Sanyo multiplexer that allows decoding of channel information (camera numbers), channels can
be specified so that only images from those channels are searched for. If any other type of multiplexer is connected, this setting is not
possible.
Press the SEARCH FRAME/FIELD button during
recording or when the digital video recorder is stopped.
The SEARCH screen appears.
Use the jog dial to select MOTION DETECTION SEARCH
and then turn the shuttle dial clockwise.
The MOTION DETECTION SEARCH screen appears.
Use the jog dial to select SEARCH FROM and then turn
the shuttle dial clockwise.
The ALARM display flashes.
Use the jog dial to select the recording area (example:
NORMAL), and then turn the shuttle dial clockwise.
The cursor moves to CHANNEL.
Note: If the setting for MULTIPLEXER in the VIDEO INPUT SET menu is set
to “NO USE”, the cursor will move to START PREVIEW.
Examples of recording area selection:
• ALARM: Only images in the alarm recording area are searched.
• NORMAL: Only images in the normal recording area are searched.
• ALARM & NORMAL: Images in both the alarm recording area and the
normal recording area are searched.
Turn the shuttle dial clockwise, use the jog dial to select
the camera number (example: 4), and then turn the
shuttle dial clockwise.
The cursor moves to START PREVIEW.
SEARCH
FRAME/FIELD
1
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
MOVE:JOG SELECT:SHUTTLE
2
ALARM SEARCH ->
ALARM THUMBNAIL SEARCH ->
TIME/DATE SEARCH ->
ARCHIVE AREA SEARCH ->
MOTION DETECTION SEARCH ->
3
SEARCH FROM : ALARM
START : -------- --:--
END : -------- --:--
CHANNEL : --
START PREVIEW ->
MOVE:JOG SELECT:SHUTTLE
4
SEARCH FROM : NORMAL
START : 28-10-01 08:00
END : 28-10-01 20:00
CHANNEL : --
START PREVIEW ->
MOVE:JOG SELECT:SHUTTLE
5
SEARCH FROM : NORMAL
START : 28-10-01 08:00
END : 28-10-01 20:00
CHANNEL : 4
START PREVIEW ->
MOVE:JOG SELECT:SHUTTLE
English
29
SEARCHING FOR RECORDED IMAGES
Turn the shuttle dial clockwise.
The screen changes and the preview screen for camera number 4 appears.
1 START: The date and time for the first image in the selected recording
area appears.
You can also select the screen which has a motion sensor set.
2 END: The date and time for the last image in the selected recording area
appears.
One hour is added to the time that is displayed.
You can also select the screen which has a motion sensor set.
3 MOTION SENSOR: The motion sensor appears.
4 PREVIEW: The selected start point appears.
If you turn the shuttle dial clockwise, you can check the
images up until the end point.
5 VIEW: The selected image appears on the monitor as a single-screen
image in a normal screen.
Turn the shuttle dial clockwise.
Use the jog dial to set the START date and time (example: 10.00 am on the
current day) for the motion sensor setting, and then turn the shuttle dial
clockwise.
The image for the specified time appears in the preview screen, and the
cursor moves to the END date and time setting location.
Turn the shuttle dial clockwise.
Use the jog dial to set the END date and time (example: 8.00 pm on the
current day) for the motion sensor setting, and then turn the shuttle dial
clockwise.
The cursor moves to MOTION SENSOR.
Turn the shuttle dial clockwise.
The motion sensor setting screen appears.
Set the motion sensor to cover the area where you would like movement to
be observed.
Move the cursor to EXIT and turn the shuttle dial clockwise. The display
returns to the MOTION DETECTION SEARCH screen. Refer to page 56 for
details on motion sensor settings.
6
SEARCH FROM : NORMAL
START : 28-10-01 08:00
END : 28-10-01 20:00
CHANNEL : 4
START PREVIEW -> SEARCHING
MOVE:JOG SELECT:SHUTTLE
SEARCH FROM : NORMAL / CHANNEL : 4
START :
28-10-01 08:00
END :
28-10-01 10:00
MOTION SENSOR ->
PREVIEW ->
VIEW ->
MOVE:JOG SELECT:SHUTTLE
1
2
3
4
5
7
SEARCH FROM : NORMAL / CHANNEL : 4
START :
28-10-01 08:00
END :
28-10-01 20:00
MOTION SENSOR ->
PREVIEW ->
VIEW ->
MOVE:JOG SELECT:SHUTTLE
SEARCH FROM : NORMAL / CHANNEL : 4
START :
28-10-01 10:00
END :
28-10-01 20:00
MOTION SENSOR ->
PREVIEW ->
VIEW ->
MOVE:JOG SELECT:SHUTTLE
8
SEARCH FROM : NORMAL / CHANNEL : 4
START :
28-10-01 10:00
END :
28-10-01 20:00
MOTION SENSOR ->
PREVIEW ->
VIEW ->
MOVE:JOG SELECT:SHUTTLE
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : 6 EXIT
30
English
SEARCHING FOR RECORDED IMAGES
Use the jog dial to move the cursor to PREVIEW, and then
turn the shuttle dial clockwise. The screen showing the
motion sensor settings appear in the preview screen
each time the shuttle dial is turned.
Note: If no motion sensor settings have been made, “NOT FOUND” appears,
so make sure that the motion sensor settings have been made
correctly.
To view a motion sensor setting in a single-screen
display, use the jog dial to move the cursor to VIEW and
then turn the shuttle dial clockwise.
The display changes from the specified image to normal playback.
Note: When using a multiplexer and the camera number has been specified
as a channel when carrying out motion detector searches, only images
for the specified camera number will be played back. For playback of
all cameras the playback has first to be switched off and then switched
on again. Furthermore, the multiplexer title information and date
information may not be fully displayed at this time in some cases.
10
1
2
SEARCH FROM : NORMAL / CHANNEL : 4
START :
28-10-01 10:00
END :
28-10-01 20:00
MOTION SENSOR ->
PREVIEW ->
VIEW ->
MOVE:JOG SELECT:SHUTTLE
11
1
2
English
31
SAVING (COPYING) RECORDED IMAGES
Important images that have been recorded onto the normal recording area or alarm recording area can be copied to a CompactFlash card or to
the archive area of the hard disk.
Note:
• Copied images are stored as a single picture.
• If you are downloading images to a CompactFlash card, the images are automatically saved in the archive area, and they are then copied
from the archive area to the CompactFlash card.
• If the archive area has become full, use the AREA FULL RESET setting for the archive area in the RECORDING AREA SET menu to delete
unneeded images.
Copying images to the hard disk archive area
Play back the images in the normal recording area or alarm recording area
that is to be copied, and pause playback at the image that is to be copied.
(See page 21.)
Example: To copy 10 seconds of images starting from a selected image
While the image to be copied is displayed as a still image,
press the COPY button.
The copy screen appears.
Use the jog dial to select COPY TO and then turn the
shuttle dial clockwise.
The ARCHIVE AREA display flashes.
Important recorded images
can be selected for copying.
Hard disk
CF card or microdrive
Images can be copied to the
archive area of the hard disk.
Images can be copied to a
CompactFlash card or to a
microdrive.
STILL
1
PLAY/STOP
COPY
2
COPY TO : ARCHIVE AREA
HOW MANY : 1 PICTURES
START ->
CHANGE WITH JOG. SET WITH SHUTTLE
3
COPY TO : ARCHIVE AREA
HOW MANY : 1 PICTURES
START ->
CHANGE WITH JOG. SET WITH SHUTTLE
32
English
SAVING (COPYING) RECORDED IMAGES
4
Use the jog dial to select ARCHIVE AREA and then turn
the shuttle dial clockwise.
The cursor moves to HOW MANY.
5
Turn the shuttle dial clockwise, use the jog dial to change
the setting to “10”, and then turn the shuttle dial
clockwise.
The cursor moves to PICTURES.
6
Use the jog dial to select the SECONDS setting, and then
turn the shuttle dial clockwise.
• PICTURES: Specify the number of images to be copied.
• SECONDES: Specify the number of seconds of images to be copied.
• MINUTES: Specify the number of minutes of images to be copied (up to
60 minutes).
The cursor moves to START.
7
Turn the shuttle dial clockwise.
Copying of images to the archive area starts. When copying is complete,
“COPY FINISHED” appears.
Note: If you press the COPY button while copying is in progress, copying is
canceled.
Copying images from archive area to a CompactFlash card
1
Insert a CompactFlash card into the CompactFlash slot
on the front panel.
When inserting the CompactFlash card, make sure that the direction of
insertion is correct.
A microdrive can also be used for copying images.
Display an image from the archive area as a still image,
and then press the COPY button.
The copying screen appears.
Refer to page 28 for details on playing back images from the archive area.
Use the jog dial to select COPY TO and then turn the
shuttle dial clockwise.
The ARCHIVE AREA display flashes.
COPY TO : ARCHIVE AREA
HOW MANY : 1 PICTURES
COPY TO : ARCHIVE AREA
HOW MANY : 10 PICTURES
COPY TO : ARCHIVE AREA
HOW MANY : 10 PICTURES
START ->
1
2
3
2
1
3
(Inserting)
(Removing)
COPY
2
COPY TO : ARCHIVE AREA
HOW MANY : 1 PICTURES
START ->
CHANGE WITH JOG. SET WITH SHUTTLE
3
COPY TO : ARCHIVE AREA
HOW MANY : 1 PICTURES
START ->
CHANGE WITH JOG. SET WITH SHUTTLE
English
33
SAVING (COPYING) RECORDED IMAGES
4
Use the jog dial to select COMPACIT FLASH and then
turn the shuttle dial clockwise.
The cursor moves to HOW MANY.
5
Turn the shuttle dial clockwise, use the jog dial to change
the setting to “10”, and then turn the shuttle dial
clockwise.
The cursor moves to PICTURES.
6
Use the jog dial to select the SECONDS setting, and then
turn the shuttle dial clockwise.
• PICTURES: Specify the number of images to be copied.
• SECONDES: Specify the number of seconds of images to be copied.
• MINUTES: Specify the number of minutes of images to be copied (up to
60 minutes).
Note:
• The limit to the number of images that can be copied to CompactFlash is
1000. Copying ends when 1000 images have been copied.
• When copying alarm recordings, they can only be copied one at a time.
7
Turn the shuttle dial clockwise.
The COPY indicator illuminates, the COPY TO : COMPACT FLASH screen
appears and copying of images to the CompactFlash card starts.
When copying is complete, “COPYING COMPLETE” appears.
Note:
• If copying images directly from the normal recording area or alarm
recording area to a CompactFlash card, the same images will also be
copied to the archive area.
• If you press the COPY button while copying is in progress, copying is
canceled.
COPY TO : COMPACT FLASH
HOW MANY : 1 PICTURES
COPY TO : COMPACT FLASH
HOW MANY : 10 PICTURES
COPY TO : COMPACT FLASH
HOW MANY : 10 SECONDES
COPY TO : COMPACT FLASH
HOW MANY : 10 SECONDES
START ->
CompactFlash recording area
1 A SANYO folder is created in the root directory.
2 Sub-folders for holding the copied images are created in
sequence in the SANYO folder.
3 The images are copied as JPEG files into the sub-folders,
with filenames starting from 00000001.JPG.
HTML files called INDEX.HTM containing the number of files
that have been copied to a folder are also copied to each
folder at this time.
4 To view the file listing using a computer, use a browser such
as Internet Explorer 5.0 or later to open the INDEX.HTM files.
The JPEG files can be played back as a slideshow.
Note:
• When frame recording images are copied to a CompactFlash card, the images are copied separately as two field images, so that frame
playback is not possible when viewing these images using a computer.
• Images that have been copied onto a CompactFlash card contain codes for detecting file tampering, and these codes can be recognized by
computer software applications that can detect file tampering. Contact the place of purchase for details.
• JPG images are recorded as field images, so that when they are viewed using the normal image viewer, they are compressed by 1/2 in the
vertical direction. Make sure that you view them using the index.htm file.
COMPACT FLASH
SANYO
00000001
00000001.JPG
00000002.JPG
INDEX.HTM
00000001.JPG
00000002.JPG
00000003.JPG
00000004.JPG
INDEX.HTM
00000002
1
2
3
4
2
3
4
34
English
SAVING (COPYING) RECORDED IMAGES
Copying to a DDS (DAT) drive
1
Insert an SCSI card (sold separately) for connecting the
DDS (DAT) drive into the PC card slot at the rear of the
digital video recorder.
Images from the archive area can be copied to the DDS (DAT) drive, and
images recorded on the DDS (DAT) drive can also be copied to the archive
area.
Note:
• Check that the direction of insertion is correct wehn inserting the SCSI card.
• If an SCSI card or DDS (DAT) drive other than the ones recommended is
used, correct operation cannot be guaranteed.
• DDS (Digital Data Strage)/DAT (Digital Audio Tape).
Backing up
All of the data in the archive area can be backed up on a DDS (DAT) drive.
Press the COPY button during recording or when the
digital video recorder is stopped.
The ARCHIVE SET screen appears.
Use the jog dial to select BACK UP and then turn the
shuttle dial clockwise.
“ARCHIVING TO DDS(DAT) !” appears, and copying then starts.
• If you press the COPY button while copying is in progress, copying is
canceled.
• When copying is completed, “ARCHIVE FINISHED!” appears. Press any
button to return to the normal screen.
Note:
• When data is converted for storage on a DDS (DAT) drive, the conversion
process may result in an increase in the size of the data. If copying
images onto a 12 GB tape, it may only be possible to copy about 10 GB of
data.
• It will take approximately 4 hours to copy 10 GB of data onto a DDS (DAT)
drive.
1
1
2
3
2
3
(Installed)
(Removed)
You can slide the
knob to lock the
card.
Return the knob
after unlocking.
• Recommended SCSI card
Manufacturer: ADAPTEC
Model No.: Slim SCSI 1460
• Recommended DDS-3 type DDS (DAT) drive
Manufacturer: Hewlett Packard
Model No.: Super Store dat 24e
Be sure to attach the accessory ferrite core
to the SCSI card connection cable.
COPY
2
BACK UP ->
RESTORE ->
ERASE ->
3
01-01-01
00:00:00 EN 0.12SEC
ARCHIVING TO DDS(DAT) !
English
35
SAVING (COPYING) RECORDED IMAGES
Reading data from a DDS (DAT) drive into the archive area
Note: All of the previously recorded images in the archive area are deleted when images are transferred in this way.
Press the COPY button during recording or when the
digital video recorder is stopped.
The ARCHIVE SET screen appears.
Use the jog dial to select RESTORE and then turn the
shuttle dial clockwise.
The message “LISTING DATA !” appears. When playback is complete, the
RESTORE FROM DDS (DAT) screen appears.
Use the jog dial to select the data to be read into the
archive area, and then turn the shuttle dial clockwise.
Reading of data starts. The RESTORE FROM DDS (DAT) screen appears.
The image data on the DDS (DAT) drive is then saved into the archive area.
When all data has been read into the archive area, “RESTORE FINISHED!”
appears.
When you play back the images in the archive area, the image data that has
been read can be played back.
COPY
1
BACK UP ->
RESTORE ->
ERASE ->
2
01-01-01
08:00:00 EN 0.12SEC
LISTING DATA !
3
NO DATE TIME SIZE
0001 13-12-2001 11:13 3.0GB
0002 15-12-2001 10:15 2.0GB
0003 17-12-2001 10:15 2.0GB
STORED DATA ON HDD WILL BE ERASED !
01-01-01
08:00:00 EN 0.12SEC
RESTORING FROM DDS(DAT) !
36
English
SAVING (COPYING) RECORDED IMAGES
Deleting DDS (DAT) drive image data
Press the COPY button during recording or when the
digital video recorder is stopped.
The ARCHIVE SET screen appears.
Use the jog dial to select ERASE and then turn the shuttle
dial clockwise.
The WARNING screen appears.
Use the jog dial to change “NO” to “YES”, and then turn
the shuttle dial clockwise.
“ERASING MEDIUM!” appears, and when erasing of data from the tape has
been completed, “ERASING FINISHED!” appears.
COPY
1
BACK UP ->
RESTORE ->
ERASE ->
2
STORED DATA ON DDS(DAT) WILL BE ERASED !
ARE YOU SURE ?
NO
CHANGE WITH JOG, SET WITH SHUTTLE
3
01-01-01
08:00:00 EN 0.12SEC
ERASING MEDIUM !
English
37
MENU FLOW CHART AND MENU
OPERATIONS
Menu flow
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
ENGLISH
01-01-2001 MON 00:00:00
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
This sub-menu lets you set the language for menu screens, the date and time that appear on the screen at all times, and summer time. It also
includes a function that lets you synchronize the time settings when more than one device is connected.
Setting the language
The menus can be displayed in one of several languages (English,
French, German and Spanish). The default language setting is
English.
1
Press the MENU button to select LANGUAGE/CLOCK
SET, and then turn the shuttle dial clockwise.
The LANGUAGE/LANGUE/SPRACHE/IDIOMA sub-menu
appears, and the cursor is moves to “ENGLISH”.
2
Turn the shuttle dial clockwise.
“ENGLISH” flashes.
3
Turn the jog dial to select the language (example:
“FRANCAIS”), and then turn the shuttle dial clockwise.
The language is switched to French and the cursor moves to
the date and time.
CLOCK SET settings
(default setting: 01-01-2001 MON 00:00:00)
You should always set the date and time correctly. This digital
video recorder includes the recording time with recorded images,
and uses this time for playback and searching.
Example: To set the date and time to 8.30 a.m. on 22 May 2002
1
When the cursor is at the date and time setting, turn the
shuttle dial clockwise.
“01” flashes.
2
Turn the jog dial to select “22: day”, and then turn the
shuttle dial clockwise.
The cursor moves to the “01” month setting and flashes.
3
Use the same procedure to set the month (5), year (2002),
hour (08), minutes (30) and seconds.
After the seconds have been set, the cursor moves to the
ADJUST TIME setting for “EXT. CLOCK SET”, and counting
starts from zero seconds.
Note: Time stops during clock setting.
ENGLISH
01-01-2001 MON 00:00:00
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
Main menu 1
Sub-menus
Sets the language.
Sets the date and time.
Set summer time.
Synchronizes the time for multiple devices.
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
ENGLISH
01-01-2001 MON 00:00:00
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
ENGLISH
01-01-2001 MON 00:00:00
1
2
FRANCAIS
01-01-2001 LUN 00:00:00
MODE : ARRET
SEMAIN MOIS HEURE
ON DER-DIM 03 02:00
OFF DER-DIM 10 02:00
REGL.DE L’HEURE 01:00
ENGLISH
01-01-2001 MON 00:00:00
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
1
2
22-01-2001 MON 00:00:00
40
English
LANGUAGE/CLOCK SET SETTINGS
SUMMER TIME SET setting
(default setting: USE)
This can be used to set the starting time and ending time for
summer time. When summer time is set, the time is automatically
advanced by one hour.
Example: To start summer time at 2.00 a.m. on the first
Sunday in April, and end it at 2.00 a.m. on the 4th
Sunday in October
1
When the cursor is at the MODE setting, turn the shuttle
dial clockwise.
“USE” flashes.
2
Turn the shuttle dial clockwise.
The cursor moves to the starting time (ON) entry line.
3
Turn the shuttle dial clockwise.
“LST” (WEEK) setting flashes.
4
Turn the jog dial clockwise to select “1ST”, and then turn
the shuttle dial.
“SUN” (WEEK) flashes.
5
Turn the jog dial clockwise to select “SUN”, and then turn
the shuttle dial clockwise.
“03” (MONTH) flashes.
6
Turn the jog dial clockwise to select “04”, and then turn
the shuttle dial clockwise.
“02” (TIME) flashes.
7
Use the same procedure to set the end of summer time.
The cursor moves to ADJUST TIME.
EXT. CLOCK SET setting
(default setting: 01:00)
If more than two devices are connected at the same time, the time
settings (ADJUST TIME) for the digital video recorder are also
applied to these devices.
1
Connect the other devices to the input terminal (CLOCK
ADJUST IN) and output terminal (CLOCK ADJUST OUT) at
the rear of the digital video recorder.
2
Turn the jog dial to move the cursor to the ADJUST TIME
setting, and then turn the shuttle dial.
“01” flashes.
3
Turn the jog dial to set the hours (example: “05”), and
then turn the shuttle dial.
4
Press the EXIT/OSD button.
The display returns to the normal screen.
5
Use the same procedure to set ADJUST TIME for the
second device.
When the settings are complete, the display returns to the
normal screen.
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
ON LST-SUN 03 02:00
ON LST-SUN 03 02:00
ON 1ST-SUN 03 02:00
MODE : USE
WEEK MONTH TIME
ON 1ST-SUN 04 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
1
2
ALARM
FULL
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
NON REC
OUT
ALARM
IN
ALARM
RESET
ALARM
FULL
WARNING
OUT
FULL
OUT
IN
ALARM
OUT
CLOCK
ADJUST
C
C
NON REC
OUT
ALARM
IN
ALARM
RESET
1
2
ENGLISH
01-01-2001 MON 00:00:00
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
ADJUST.TIME 01:00
ADJUST.TIME 05:00
EXIT/OSD
English
41
VIDEO INPUT SET SETTING
If you select a multiplexer (sold separately) that is connected to the digital video recorder, you can set the type of image input (digital or analog).
MULTIPLEXER setting
(default setting: NO USE)
1
Press the MENU button to select VIDEO INPUT SET, and
then turn the shuttle dial clockwise.
The VIDEO INPUT SET sub-menu appears, and the cursor
moves to MULTIPLEXER.
2
Turn the shuttle dial clockwise.
“NO USE” flashes.
3
Turn the jog dial to select the MULTIPLEXER setting
(example: “SANYO”), and then turn the shuttle dial
clockwise.
Display examples:
• NO USE: When not using a multiplexer
• SANYO: When using a Sanyo multiplexer
• OTHERS1: When using a Sony multiplexer
• OTHERS2: When using a Robot or DM multiplexer
The cursor moves to VIDEO INPUT.
Note: The multiplexers specified by SANYO and OTHERS1 are
capable of decoding channel information. Accordingly, you
can record images from these multiplexers using this digital
video recorder, and then use the digital video recorder’s
CHANNEL button to select a camera number (channel
information) for playback.
VIDEO INPUT setting
(default setting: ANALOG)
This sets whether the image signals that are being input to the
video input terminals of this digital video recorder are digital or
analog.
1
When the cursor is at the VIDEO INPUT setting, turn the
shuttle dial clockwise.
“ANALOG” flashes.
2
Turn the jog dial to select “DIGITAL (example)”, and then
turn the shuttle dial.
The cursor moves to MULTIPLEXER.
Note:
• Select this if a Sanyo digital transport multiplexer
(MPX-CD163P or CD93P) has been connected digitally.
• When making a multiplexer and a digital connection, first
connect the VIDEO OUT connector of this unit to the
monitor, and then set the input signal to “DIGITAL”.
3
Press the EXIT/OSD button.
The display returns to the normal screen.
Note:
• If the MULTIPLEXER setting is set to something other than “NO
USE”, SENSOR cannot be selected as the ALARM TRIGGER
in the ALARM REC MODE SET menu.
When using a multiplexer, use the motion sensor function of the
multiplexer.
• If using a multiplexer manufactured by SANYO or some other
manufacturer in analog connection mode, connect the SW OUT
terminal at the rear of this unit to the SW IN terminal of the
multiplexer. This is not necessary if using a SANYO multiplexer
in digital connection mode.
MULTIPLEXER : NO USE
VIDEO INPUT : ANALOG
Main menu 1
Sub-menus
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
Sets the manufacturer of the connected
multiplexer.
Sets the video input.
MENU
MULTIPLEXER : NO USE
VIDEO INPUT : ANALOG
MULTIPLEXER : NO USE
VIDEO INPUT : ANALOG
MULTIPLEXER : SANYO
VIDEO INPUT : ANALOG
1
2
MULTIPLEXER : SANYO
VIDEO INPUT : ANALOG
MULTIPLEXER : SANYO
VIDEO INPUT : DIGITAL
1
2
EXIT/OSD
42
English
RECORDING AREA SET SETTING
TOTAL CAPACITY display
This shows the total recording capacity of the hard disk. This
display cannot be changed except when the hard disk capacity
itself is changed.
With the initial hard disk setting, the normal recording area takes up
80%, the alarm recording area takes up 19% and the archive area
takes up 1% of the disk capacity. The upper limit is 12 GB (15% of
total capacity when using an 80-GB hard disk), so you cannot set a
value greater than this.
The assignment of space to each recording area is displayed as a
percentage of the total. The normal recording area and alarm
recording area together can be set to a maximum of 99% of the
total space.
The archive area cannot be set manually. It is forcibly assigned to a
minimum of 1%. Accordingly, if the normal recording area and the
alarm recording area are set to a total of 85%, the archive area will
be automatically set to 15%.
For example, if the normal recording area is set to 0% and the
alarm recording area is set to 99%, normal recording images will
not be saved onto the hard disk. Only alarm recording images will
be saved. The recording capacity for each recording area should
be assigned according to the requirements of the particular
recording location.
If an additional hard disk is added, the increased capacity will be
included in the TOTAL CAPACITY display.
Note:
• If you change the assignment of space to each recording area
of the hard disk while recording is in progress, the images which
have been recorded up until that point will be erased. This is
because the hard disk itself is initialized during this operation,
so be very careful when making this kind of setting. If you need
to change the sizes of the recording areas for some reason,
make sure that you make a backup copy of the images on some
other medium such as a computer.
• Make sure that the OVERWRITE setting is “OFF” before moving
the cursor to “AREA FULL RESET →” for either the NORMAL
RECORDING AREA or the ALARM RECORDING AREA. (See
page 45.)
• When installing an additional hard disk and the MIRRORING of
the HDD SET setting has been set to “ON”, the TOTAL
CAPACITY display of RECORDING AREA SET shows a
smaller value for the hard disk capacity.
Resetting each recording area
Example: Set the normal recording area to 50% and the alarm
recording area to 49%
1
Press the MENU button to select RECORDING AREA SET,
and then turn the shuttle dial clockwise.
The RECORDING AREA SET sub-menu appears, and the
cursor moves to NORMAL RECORDING AREA.
2
Use the jog dial to move the cursor to the NORMAL
RECORDING AREA setting, and then turn the shuttle dial
clockwise.
“80%” flashes.
3
Use the jog dial to change the setting, for example from
“80%” to “50%”, and then turn the shuttle dial clockwise
The cursor moves to ALARM RECORDING AREA.
4
Turn the shuttle dial clockwise.
“35%” flashes.
5
Turn the jog dial to change the setting, for example from
34% to 49%, and then turn the shuttle dial clockwise.
The cursor moves to AREA FULL RESET.
TOTAL CAPACITY : 80GB
NORMAL RECORDING AREA : 80 %
AREA FULL RESET ->
ALARM RECORDING AREA : 19 %
AREA FULL RESET ->
ARCHIVE AREA : 1 %
AREA FULL RESET ->
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
Main menu 1
Sub-menus
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
Displays the total hard
disk capacity.
Sets the capacity of the normal
recording area.
Sets the capacity of the alarm recording
area.
Sets the capacity of the archive area.
Normal
recording
area
Alarm
recording
area
Archive area
MENU
TOTAL CAPACITY : 80GB
NORMAL RECORDING AREA : 49 %
AREA FULL RESET ->
ALARM RECORDING AREA : 40 %
AREA FULL RESET ->
ARCHIVE AREA : 2 %
AREA FULL RESET ->
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
English
43
RECORDING AREA SET SETTING
6
Turn the shuttle dial counterclockwise.
The screen changes to show a “WARNING” display. This is a
message to warn you that the hard disk is about to be
reinitialized.
7
To reinitialize the hard disk, turn the jog dial to display
“YES”, and then turn the shuttle dial clockwise.
The RECORDING AREA SET screen appears and the
recording capacities for each area are changed.
Note: If you turn the shuttle dial clockwise when “NO” is selected,
the RECORDING AREA SET screen appears and the
recording capacities return to their previous settings. The
hard disk is not reinitialized in this case.
AREA FULL RESET setting
When the normal recording area and alarm recording area of the
hard disk become full, the images in the recording areas will be
automatically overwritten, starting from the oldest images that have
been recorded.
However, you can change this setting to prevent overwriting of
images when the recording areas become full, at times such as
when you want to check or edit the recorded images. In this case
you need to specify each time that you want images to be
overwritten in each recording area. The following procedure
describes the method of doing this.
1
Set the OVERWRITE setting for the NORMAL RECORDING
AREA or ALARM RECORDING AREA to “OFF” in the
RECORDING CONDITIONS SET menu.
This setting can be used to display the remaining recording
area of the hard disk on the screen. At the same time, the
FULL or ALARM FULL indicator at the front of the digital video
recorder will flash.
When writing to the hard disk is complete, you can use
playback operations to check the recordings.
2
Use the jog dial to move the cursor to the AREA FULL
RESET → setting for the NORMAL RECORDING AREA,
and then turn the shuttle dial clockwise.
“NO” flashes on the WARNING screen.
3
Use the jog dial to change “NO” to “YES”, and then turn
the shuttle dial clockwise.
The NORMAL RECORDING AREA is set to single overwriting.
4
Follow the same procedure to make the setting for the
ALARM RECORDING AREA.
5
Press the EXIT/OSD button.
The display returns to the normal screen.
Note:
• For overwriting to be carried out automatically, change the
OVERWRITE setting for the NORMAL RECORDING AREA or
ALARM RECORDING AREA to “ON”.
• If AREA FULL RESET is carried out, the normal recording area,
alarm recording area and archive area will all be reinitialized,
and it will no longer be possible to play back any images that
have already been recorded.
THIS CHANGE WILL INITIALIZE THE DISK.
ALL RECORDING WILL BE ERASED.
ARE YOU SURE ?
NO
CHANGE WITH JOG. SET WITH SHUTTLE
THIS CHANGE WILL INITIALIZE THE DISK.
ALL RECORDING WILL BE ERASED.
ARE YOU SURE ?
YES
CHANGE WITH JOG. SET WITH SHUTTLE
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : ON
ALARM RECORDING AREA
OVERWRITE : ON
REMAINING DISK WARNING : **
TOTAL CAPACITY : 80GB
NORMAL RECORDING AREA : 80 %
AREA FULL RESET ->
ALARM RECORDING AREA : 19 %
AREA FULL RESET ->
ARCHIVE AREA : 1 %
AREA FULL RESET ->
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
AREA FULL RESET
NORMAL RECORDING AREA
ARE YOU SURE ?
NO
CHANGE WITH JOG. SET WITH SHUTTLE
EXIT/OSD
44
English
RECORDING CONDITIONS SET SETTING
This lets you make settings and set overwriting permissions for each recording area when multiple digital video recorders (up to a maximum of
three) are connected for series recording.
Recording settings for digital series
connection (maximum 3 units)
1
Connect the digital video recorders using the digital input
and output terminals of each digital video recorder.
(See page 8.)
Note: Use a straight-type Ethernet cable to connect the digital
video recorders. Each cable should not be any longer than 3
meters.
2
Press the MENU button to select RECORDING
CONDITIONS SET, and then turn the shuttle dial
clockwise.
The RECORDING CONDITIONS SET sub-menu appears,
and the cursor moves DIGITAL SERIES RECORDING.
3
Turn the shuttle dial clockwise.
“OFF” flashes.
4
Use the jog dial to change the setting to “ON”, and then
turn the shuttle dial clockwise.
The cursor moves to TOTAL NUMBER.
5
Turn the shuttle dial clockwise, use the jog dial to set the
total number of digital video recorders connected
(example: 3), and then turn the shuttle dial clockwise.
The cursor moves to RECORDING NUMBER.
6
Turn the shuttle dial clockwise, use the jog dial to set the
connection number (example: 1), and then turn the
shuttle dial clockwise.
The cursor moves to OVERWRITE.
Note:
• The digital video recorder which is used as the main unit should
always have its connection number set to 1.
• Do not skip or overlap numbers when making the settings.
• If NETWORK CONTROL in the NETWORK SET menu has
been set to “ON”, DIGITAL SERIES RECORDING cannot be
selected. Conversely, if DIGITAL SERIES RECORDING has
been set to “ON”, NETWORK CONTROL cannot be set to “ON”.
Sub-menus
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : ON
ALARM RECORDING AREA
OVERWRITE : ON
REMAINING DISK WARNING : **
Main menu 1
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
Sets series recording.
Sets the number of digital video recorders
connected.
Sets the number of units connected.
Sets overwriting for the normal recording
area.
Sets overwriting for the alarm recording
area.
Sets the remaining space warning for the
recording areas.
MENU
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : ON
ALARM RECORDING AREA
OVERWRITE : ON
REMAINING DISK WARNING : **
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
DIGITAL SERIES RECORDING : ON
TOTAL NUMBER : 2
RECORDING NUMBER : 1
DIGITAL SERIES RECORDING : ON
TOTAL NUMBER : 3
RECORDING NUMBER : 1
English
45
RECORDING CONDITIONS SET SETTING
Setting NORMAL RECORDING AREA
OVERWRITE and REMAINING DISK
WARNING on the operating display
section
When the recording areas of the hard disk become full, you can set
whether old images are to overwritten, or whether recording should
stop. If recording is set to stop, the current percentage of free
space remaining on the hard disk will appear on the operating
display section. You can use [REMAINING DISK WARNING] to
specify the amount of free space remaining.
1
When the cursor is at the OVERWRITE setting, turn the
shuttle dial clockwise.
“ON” flashes.
2
Use the jog dial to select the setting (example: OFF), and
then turn the shuttle dial clockwise.
REMAINING DISK WARNING changes from ** to 1%.
Display examples:
• OFF: When the normal recording area becomes full,
recording stops.
• ON: When the normal recording area becomes full, images
are overwritten automatically starting from the earliest
recorded images.
Note: If “OFF” is selected, the REMAINING DISK WARNING
setting shows the percentage of hard disk space remaining
that triggers the FULL or ALARM FULL indicator to start
flashing.
3
Follow the same procedure to make the setting (OFF) for
the ALARM RECORDING AREA.
Note: Make the settings separately for each item in the menu,
even if making a digital connection. The OVERWRITE
settings for second and subsequent units must match the
setting for the first unit.
4
When the cursor is at the REMAINING DISK WARNING
setting, turn the shuttle dial clockwise, and then use the
jog dial to set the display value for the amount of disk
space remaining (example: “5”).
Note: The REMAINING DISK WARNING setting can be between
1% (default setting) and 10%.
5
Press the EXIT/OSD button.
The display returns to the normal screen.
When the remaining disk space in each area reaches 5%, it is
displayed in the operating display section. The FULL (for
normal recording area) or ALARM FULL (for alarm recording
area) indicator on the front of the digital video recorder flashes.
Relationship between RECORDING AREA
SET and OVERWRITE
If the normal recording area and alarm recording area become full,
select AREA FULL RESET for the normal recording area or alarm
recording area in the RECORDING AREA SET menu. (See page
43.)
Note: No audio input is provided from the digital video input
terminals. Audio signals can be input as analog signals via
the audio input terminals (such as the MIC terminal).
For details on CONNECTIONS, see page 10.
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : ON
ALARM RECORDING AREA
OVERWRITE : ON
REMAINING DISK WARNING : **
FULL
ALARM FULL
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : OFF
ALARM RECORDING AREA
OVERWRITE : ON
REMAINING DISK WARNING : 1%
FULL
ALARM FULL
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : OFF
ALARM RECORDING AREA
OVERWRITE : OFF
REMAINING DISK WARNING : 5%
1
2
FULL
ALARM FULL
EXIT/OSD
POWER
LOCK
FULL
ALARM FULL
ALARM FULL
FULL
ALARM FULL
5%
01-01-01
00:00:00 EN 0.12SEC
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER : **
RECORDING NUMBER : **
NORMAL RECORDING AREA
OVERWRITE : ON
ALARM RECORDING AREA
OVERWRITE : ON
REMAINING DISK WARNING : **
TOTAL CAPACITY : 80GB
NORMAL RECORDING AREA : 80 %
AREA FULL RESET ->
ALARM RECORDING AREA : 19 %
AREA FULL RESET ->
ARCHIVE AREA : 1 %
AREA FULL RESET ->
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
FULL
ALARM FULL
46
English
NORMAL REC MODE SET SETTING
NORMAL REC MODE SET setting
This lets you set the recording quality, recording method (frame or
field), audio recording and recording speed for the normal recording
area.
1
Press the MENU button to select NORMAL REC MODE
SET, and then turn the shuttle dial clockwise.
The NORMAL REC MODE SET sub-menu appears, and the
cursor moves to PICTURE QUALITY.
2
Turn the shuttle dial clockwise.
“ENHANCED” flashes.
Display examples: Picture quality selection
• BASIC (BA): (15 KB)
• NORMAL (NO): (22 KB)
• ENHANCED (EN): (30 KB)
• FINE (FI): (42 KB)
• SUPER FINE (SF): (56 KB)
3
Use the jog dial to change select the image quality
(example: “SUPER FINE”), and then turn the shuttle dial
clockwise.
The cursor moves to FRAME/FIELD RECORDING.
4
Turn the shuttle dial clockwise, use the jog dial to set
frame or field recording (example: FRAME), and then turn
the shuttle dial clockwise.
The cursor moves to AUDIO RECORDING.
5
Turn the shuttle dial clockwise, use the jog dial to set
audio recording (example: “ON”), and then turn the
shuttle dial.
The cursor moves to REC CYCLE.
Note:
• Audio recording can be set when the REC CYCLE setting is
from 0.02 to 0.12 (FIELD) or 0.04 to 0.24 (FRAME).
• When set to “ON”, the letter “A” (audio recording indicator)
appears in front of the REC CYCLE recording rate. This is
because the audio recordings are also made in the normal
recording area, so that the image recording capacity of the
normal recording area is reduced.
6
Turn the shuttle dial clockwise, use the jog dial to set the
recording speed (example: “0.16”), and then turn the
shuttle dial.
The cursor moves to PICTURE QUALITY.
Note: The field and frame recording speeds vary depending on the
PICTURE QUALITY setting. Refer to the Recording speed
table for details. (See page 10.)
7
Press the EXIT/OSD button.
The display returns to the normal screen.
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
REC CYCLE : 0.12 SEC ( 65H)
Main menu 1
Sub-menus
Sets the image quality.
Sets the recording method
(frame or field).
Sets audio recording.
Sets the recording rate (recording speed).
Numbers in brackets indicate the possible
recording times.
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
REC CYCLE : 0.12 SEC ( 65H)
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
REC CYCLE : 0.12 SEC ( 65H)
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
REC CYCLE : 0.12 SEC ( 65H)
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : OFF
REC CYCLE : 0.24 SEC ( 58H)
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
REC CYCLE : A0.24 SEC ( 35H)
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
REC CYCLE : A0.16 SEC ( 86H)
EXIT/OSD
English
47
TIMER SET SETTING
Use the timer function of the digital video recorder to set the times for timer recording.
TIMER SET setting
This sets the starting time and stopping time for each day, and also
sets the recording speed.
1 WEEK
This selects the day for the timer setting. While a day is flashing
another day can be selected. The 7th line (SAT) and 8th line
(DLY) are used for setting a timer recording for a period of more
than 24 hours.
2 START
This is used to enter the starting time for timer recording.
3 STOP
This is used to enter the stopping time for timer recording.
4 REC CYCLE
• Sets the recording speed.
The initial setting is for FIELD (0.12SEC) recording. If the
setting is changed to frame recording, the recording speed
becomes 0.24SEC.
• The numbers in brackets are the result of automatic
calculation of the available time based on the recording
method, picture quality and audio recording settings. The
maximum value that can be displayed is 9999H. If the
available time is 10000H or more, the display appears as
9999*.
5 SET
Set to “ON” when using timer recording.
Set to “OFF” when not using timer recording.
6 For setting a timer recording of more than 24 hours.
Use this line for a timer recording of more than 24 hours.
Note: The picture quality, frame/field recording and audio
recording settings for timer recording will be the settings
used for recording in the normal recording area.
Timer reservations every day at the
same time with the same image quality
Example: Timer recording every day from 8:30 a.m. to 6:30
p.m. at the same recording speed
1
Press the MENU button to select TIMER SET, and then
turn the shuttle dial clockwise.
The TIMER SET sub-menu appears, and the cursor moves to
SUN.
2
Turn the shuttle dial clockwise.
“SUN” flashes in the WEEK column.
3
Use the jog dial to change from “SUN” to “DLY”, and then
turn the shuttle dial.
“– –” (hours) flashes in the START column.
WEEK START STOP REC CYCLE SET
SUN --:-- --:-- 0.12SEC ( 65H) OFF
MON --:-- --:-- 0.12SEC ( 65H) OFF
TUE --:-- --:-- 0.12SEC ( 65H) OFF
WED --:-- --:-- 0.12SEC ( 65H) OFF
THU --:-- --:-- 0.12SEC ( 65H) OFF
FRI --:-- --:-- 0.12SEC ( 65H) OFF
SAT --:-- --:-- 0.12SEC ( 65H) OFF
DLY --:-- --:-- 0.12SEC ( 65H) OFF
Sub-menus
Main menu 1
1
5
4
3
2
Sets the timer.
The timer must be set when carrying out
timer recording.
6
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
WEEK START STOP REC CYCLE SET
SUN --:-- --:-- 0.12SEC ( 65H) OFF
MON --:-- --:-- 0.12SEC ( 65H) OFF
TUE --:-- --:-- 0.12SEC ( 65H) OFF
WED --:-- --:-- 0.12SEC ( 65H) OFF
THU --:-- --:-- 0.12SEC ( 65H) OFF
FRI --:-- --:-- 0.12SEC ( 65H) OFF
SAT --:-- --:-- 0.12SEC ( 65H) OFF
DLY --:-- --:-- 0.12SEC ( 65H) OFF
SUN --:-- --:-- 0.12SEC ( 65H) OFF
DLY --:-- --:-- 0.12SEC ( 65H) OFF
48
English
TIMER SET SETTING
4
Use the jog dial to change from “– –” to “08”, and then
turn the shuttle dial clockwise.
“– –” (minutes) flashes in the START column.
5
Use the jog dial to change from “– –” to “30”, and then
turn the shuttle dial clockwise.
“– –” (hours) flashes in the STOP column.
6
Use the jog dial to change from “– –” to “18”, and then
turn the shuttle dial clockwise.
“– –” (minutes) flashes in the STOP column.
7
Use the jog dial to change from “– –” to “30”, and then
turn the shuttle dial clockwise.
“0.12” (recording speed) flashes in the REC CYCLE column.
8
Use the jog dial to set the recording speed to “0.16”
(86H), and then turn the shuttle dial clockwise.
“OFF” flashes in the SET column.
Note: The image quality for timer recording will be the image
quality that was set by PICTURE QUALITY in the NORMAL
REC MODE SET sub-menu.
Example: The recording will be SUPER FINE. Then
recording speed the same as the speed previously set.
9
Use the jog dial to change “OFF” to “ON”, and then turn
the shuttle dial clockwise.
The cursor moves to MON.
10 Press the EXIT/OSD button.
The display returns to the normal screen.
Note:
• If you want to use different days, times, and recording speeds
for timer recording, select the respective WEEK column and
make the required settings.
• If timer reservations overlap each other, the one that starts first
will have priority.
• To delete all timer reservations (including time settings), press
the MENU RESET button of the front panel.
DLY 08:-- --:-- 0.12SEC ( 65H) OFF
DLY 08:30 --:-- 0.12SEC ( 65H) OFF
DLY 08:30 18:-- 0.12SEC ( 65H) OFF
DLY 08:30 18:30 0.12SEC ( 65H) OFF
DLY 08:30 18:30 0.16SEC ( 86H) OFF
WEEK START STOP REC CYCLE SET
DLY 08:30 18:30 0.16SEC ( 86H) ON
MON --:-- --:-- 0.12SEC ( 65H) OFF
TUE --:-- --:-- 0.12SEC ( 65H) OFF
WED --:-- --:-- 0.12SEC ( 65H) OFF
THU --:-- --:-- 0.12SEC ( 65H) OFF
FRI --:-- --:-- 0.12SEC ( 65H) OFF
SAT --:-- --:-- 0.12SEC ( 65H) OFF
DLY --:-- --:-- 0.12SEC ( 65H) OFF
EXIT/OSD
JOG
SHUTTLE
E
N
T
E
R
C
L
E
A
R
MENU
RESET
English
49
TIMER SET SETTING
Timer reservations spanning more than
24 hours
To make 24-hour timer reservations, use lines 7 (SAT) and 8 (DLY)
of the menu screen.
Example: To set timer recording from 10.30 a.m. on Monday to
8.30 p.m. on Wednesday
1
Use the jog dial to move the cursor to the 7th line (SAT),
and then turn the shuttle dial.
“SAT” flashes in the WEEK column.
2
Use the jog dial to change from “SAT” to “MON”, and
then turn the shuttle dial clockwise.
“– –” (hours) flashes in the START column.
3
Use the jog dial to change from “– –” to “10”, and then
turn the shuttle dial clockwise.
“– –” (minutes) flashes in the START column.
4
Use the jog dial to change from “– –” to “30”, and then
turn the shuttle dial clockwise.
“– –” (hours) flashes in the STOP column.
5
Use the jog dial to change from “– –” to “**”, and then
turn the shuttle dial clockwise.
The DLY setting on the 8th line automatically changes to the
following day (TUE) of the weekday indicated in the 7th line
changed to “TUE”. Parts which do not need to be set appear
with a “*” symbol.
6
Use the jog dial to change from “TUE” to “WED”, and
then turn the shuttle dial clockwise.
“– –” (hours) flashes in the STOP column.
7
Use the jog dial to change from “– –” to “20”, and then
turn the shuttle dial clockwise.
“– –” (minutes) flashes in the STOP column.
8
Use the jog dial to change from “– –” to “30”, and then
turn the shuttle dial clockwise.
“0.12” (recording speed) flashes in the REC CYCLE column.
9
Use the jog dial to change from “0.12” to “0.20” (108H),
and then turn the shuttle dial clockwise.
“OFF” flashes in the SET column.
10 Use the jog dial to change from “OFF” to “ON”, and then
turn the shuttle dial clockwise.
The cursor moves to the first line.
11 Press the EXIT/OSD button.
The display returns to the normal screen.
WEEK START STOP REC CYCLE SET
SUN --:-- --:-- 0.12SEC ( 65H) OFF
MON --:-- --:-- 0.12SEC ( 65H) OFF
TUE --:-- --:-- 0.12SEC ( 65H) OFF
WED --:-- --:-- 0.12SEC ( 65H) OFF
THU --:-- --:-- 0.12SEC ( 65H) OFF
FRI --:-- --:-- 0.12SEC ( 65H) OFF
SAT --:-- --:-- 0.12SEC ( 65H) OFF
DLY --:-- --:-- 0.12SEC ( 65H) OFF
MON --:-- --:-- 0.12SEC ( 65H) OFF
MON 10:30 --:-- 0.12SEC ( 65H) OFF
MON 10:30 ¤¤:¤¤ ¤¤¤SEC (¤¤¤¤¤) ¤¤¤
TUE ¤¤:¤¤ --:-- ---SEC (----H) OFF
WED ¤¤:¤¤ --:-- 0.12SEC ( 65H) OFF
WED ¤¤:¤¤ 20:30 0.12SEC ( 65H) OFF
WED ¤¤:¤¤ 20:30 0.20SEC ( 108H) OFF
MON 10:30 ¤¤:¤¤ ¤¤¤SEC (¤¤¤¤¤) ¤¤¤
WED ¤¤:¤¤ 20:30 0.20SEC ( 108H) ON
EXIT/OSD
50
English
HOLIDAY SET SETTING
HOLIDAY SET setting
Days such as designated national holidays and company holidays
are treated in the same way as normal weekdays. Naturally timer
recording is carried out in the same way for these days, but if you
set the HOLIDAY SET setting to “SET:ON” in the menu timer
settings and then specify the dates for the holidays in this menu
screen, the same sort of timer reservations can be made for
holidays.
Note: For a timer setting make sure that you make the time
settings for Sunday (SUN) before changing SET to “ON”.
Example: To set 17 November as a holiday
1
Press the MENU button to select HOLIDAY SET, and then
turn the shuttle dial clockwise.
The HOLIDAY SET sub-menu appears, and the cursor moves
to the line 1.
2
Turn the shuttle dial clockwise.
“– –” (day) flashes in the line 1.
3
Use the jog dial to change from “– –” to “17”, and then
turn the shuttle dial clockwise.
“– –” (month) flashes in the line 1.
4
Use the jog dial to change from “– –” to “11”, and then
turn the shuttle dial clockwise.
The cursor moves to the line 2.
5
Follow the same procedure to set other holiday dates.
6
Press the EXIT/OSD button.
The display returns to the normal screen.
1. ----- 11. -----
2. ----- 12. -----
3. ----- 13. -----
4. ----- 14. -----
5. ----- 15. -----
6. ----- 16. -----
7. ----- 17. -----
8. ----- 18. -----
9. ----- 19. -----
10. ----- 20. -----
Main menu 1
Sub-menus
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
Sets an ordinary day to a holiday.
WEEK START STOP REC CYCLE SET
SUN 08:00 18:00 0.32SEC ( 173H) ON
MON --:-- --:-- 0.12SEC ( 65H) OFF
TUE --:-- --:-- 0.12SEC ( 65H) OFF
WED --:-- --:-- 0.12SEC ( 65H) OFF
THU --:-- --:-- 0.12SEC ( 65H) OFF
FRI --:-- --:-- 0.12SEC ( 65H) OFF
SAT --:-- --:-- 0.12SEC ( 65H) OFF
DLY --:-- --:-- 0.12SEC ( 65H) OFF
MENU
1. ----- 11. -----
2. ----- 12. -----
3. ----- 13. -----
4. ----- 14. -----
5. ----- 15. -----
1. -----
1. -----
1. 17---
1. 17-11
2. -----
1
2
EXIT/OSD
English
51
ALARM REC MODE SET SETTING
ALARM REC MODE SET setting
This lets you set the recording quality, recording method (frame or
field), audio recording and recording speed for the alarm recording
area.
1
Press the MENU button to select ALARM REC MODE SET,
and then turn the shuttle dial clockwise.
The ALARM REC MODE SET sub-menu appears, and the
cursor moves to PICTURE QUALITY.
2
Turn the shuttle dial clockwise.
“ENHANCED” flashes.
3
Use the jog dial to select the image quality (example:
“SUPER FINE”), and then turn the shuttle dial clockwise.
The cursor moves to FRAME/FIELD RECORDING.
Note: The maximum number of images that can be recorded
based on the various alarm recording settings is shown
below.
=> (30721 ALARMS CAN BE RECORDED)
(Image quality settings)
• BASIC (BA): (15 KB)
• NORMAL (NO): (22 KB)
• ENHANCED (EN): (30 KB)
• FINE (FI): (42 KB)
• SUPER FINE (SF): (56 KB)
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
Sub-menus
Main menu 1
Sets the image quality.
Sets the recording method (frame or field).
Sets audio recording.
Sets alarm recording.
Sets the recording rate (recording speed) and the alarm time
duration.
Sets pre-alarm recording.
Sets the recording rate (recording speed) and the alarm time
duration for pre-alarm recording.
Sets the alarm trigger.
Sets the motion sensors (alarm).
1.LANGUAGE/CLOCK SET
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
5.NORMAL REC MODE SET ->
6.TIMER SET ->
7.HOLIDAY SET ->
8.ALARM REC MODE SET ->
TO MAIN MENU 2 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.12SEC. DURATION: 1SEC
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
52
English
ALARM REC MODE SET SETTING
4
Turn the shuttle dial clockwise, use the jog dial to set the
recording method (example: “FRAME”), and then turn the
shuttle dial clockwise.
The cursor moves to AUDIO RECORDING.
Note:
• When FRAME/FIELD RECORDING is selected, the recording
speed appears in REC CYCLE and the maximum number of
recordings appears after it in brackets.
=> (30721 ALARMS CAN BE RECORDED)
• The field and frame recording speeds vary depending on the
PICTURE QUALITY setting. Refer to the Recording speed table
for details. (See page 10.)
5
Turn the shuttle dial clockwise, use the jog dial to set
audio recording (example: “ON”), and then turn the
shuttle dial.
The cursor moves to ALARM RECORDING.
Note:
• Audio recording can be set when the REC CYCLE setting is
0.12 SEC (FIELD) or 0.24 SEC (FRAME) or more.
• When set to “ON”, the letter “A” (audio recording indicator)
appears in front of the REC CYCLE recording speed, and the
maximum number of recordings appears after it in brackets.
=> (30200 ALARMS CAN BE RECORDED)
6
Turn the shuttle dial clockwise, use the jog dial to set
alarm recording mode (example: “MODE1”), and then turn
the shuttle dial.
The cursor moves to REC CYCLE.
Display example: Alarm recording settings
• OFF: Alarm recording is not carried out.
• MODE1: Alarm recording is always carried out regardless
of the timer recording settings.
• MODE2: Alarm recording is only carried out when timer
recording is in progress.
• MODE3: Alarm recording is only carried out when timer
recording is not in progress
• MODE4: Alarm recording is carried out only during the
times set by the timer. This cannot be used for
normal recording.
Note: If alarm recording is set to a setting such as MODE1,
PRE-ALARM RECORDING setting will be enabled (“***”
will change to “OFF”).
7
Turn the shuttle dial clockwise, use the jog dial to set the
recording speed (example: “0.16”), and then turn the
shuttle dial.
DURATION of “1SEC” flashes.
Note: When the recording speed is selected, the maximum number
of recordings appears after it in brackets.
=> (20480 ALARMS CAN BE RECORDED)
8
Use the jog dial to set the recording time duration
(example: “5”), and then turn the shuttle dial.
The cursor moves to PRE-ALARM RECORDING.
9
Press the EXIT/OSD button.
The display returns to the normal screen.
Alarm settings appear in the operating display section. When
an alarm is triggered, the number of alarms is displayed.
Note: If another alarm occurs while alarm recording is in progress,
alarm recording continues with images for the second alarm
being recorded from the point where the second alarm
occurred.
If several alarms have occurred at the same time, they are
treated as a single alarm until the alarms stop.
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.24SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
ALARM RECORDING : OFF
REC CYCLE : A0.24SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
ALARM RECORDING : MODE1
REC CYCLE : A0.16SEC. DURATION: 5SEC
PRE-ALARM RECORDING : OFF
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (04026 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
EXIT/OSD
01-01-01 ALARM 0000
05:53:44 SF 0.16SEC
English
53
ALARM REC MODE SET SETTING
Pre-alarm recording setting
1
Use the jog dial to move the cursor to the ALARM
RECORDING setting, and then turn the shuttle dial
clockwise.
“OFF” flashes.
2
Use the jog dial to change the “OFF” setting to some
other mode (example: MODE1), and then turn the shuttle
dial clockwise.
The PRE-ALARM RECORDING setting changes from “***”
to “OFF”.
The cursor moves to REC CYCLE.
3
Use the jog dial to move the cursor to the PRE-ALARM
RECORDING setting, and then turn the shuttle dial
clockwise.
“OFF” flashes.
4
Use the jog dial to change from “OFF” to “ON”, and then
turn the shuttle dial clockwise.
The cursor moves to REC CYCLE.
5
Turn the shuttle dial clockwise, use the jog dial to set the
recording speed (example: “A0.24”), and then turn the
shuttle dial clockwise.
The cursor moves to the “1SEC” setting for DURATION and
flashes.
6
Use the jog dial to set the recording time duration
(example: “5SEC”), and then turn the shuttle dial
clockwise.
The cursor moves to ALARM TRIGGER.
7
Press the EXIT/OSD button.
The display returns to the normal screen.
“PRE” appears in the operating display section. When an
alarm is triggered, the display switches to “ALARM”.
Note:
• Pre-alarm recording continues for the length of time specified by
the DURATION setting before an alarm signal is input. When
playing back images that have been recorded during pre-alarm
recording, use the alarm search (SEARCH FRAME/FIELD
button) operations. Images will be played back from the point
that the alarm occurred, so use the shuttle operations to carry
out rewind playback.
• If pre-alarm recording is being carried out in FIELD (recording
rate) mode, the cycle speed for the recording cycle settings will
become slower, and the 0.02 second and 0.04 second settings
cannot be selected.
• If carrying out normal alarm recording and pre-alarm recording
at the same time, no audio signals will be recorded with the
pre-alarm recording images.
• If using the digital video recorder together with a multiplexer, the
switching signal from the multiplexer will be output in
accordance with the digital video recorder’s recording timing for
normal recording if pre-alarm recording and normal recording
are being carried out at the same time. Because of this, if the
recording cycle for pre-alarm recording is shorter than the
recording cycle setting for normal recording, pre-alarm
recording images from one camera may be continuously
recorded. On the other hand, if the recording cycle for pre-alarm
recording is longer than the recording cycle setting for normal
recording, camera images may not be recorded at all during
normal recording, so this setting should not be made.
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
ALARM RECORDING : OFF
REC CYCLE : A0.16SEC. DURATION: 5SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
ALARM RECORDING : MODE1
REC CYCLE : A0.16SEC. DURATION: 5SEC
PRE-ALARM RECORDING : OFF
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
ALARM RECORDING : MODE1
REC CYCLE : 0.12SEC. DURATION: 5SEC
PRE-ALARM RECORDING : OFF
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
PRE-ALARM RECORDING : ON
REC CYCLE : A0.24SEC. DURATION: 1SEC
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
PRE-ALARM RECORDING : ***
REC CYCLE : A0.24SEC. DURATION: 1SEC
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
REC CYCLE : 0.12SEC. DURATION: 5SEC
PRE-ALARM RECORDING : ON
REC CYCLE : A0.24SEC. DURATION: 5SEC
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
EXIT/OSD
01-01-01 PRE 0000
06:46:15 SF 0.32SEC
Recording
Rate
(field/sec)
Recording
Cycle (SEC)
PICTU
BASIC
NORMAL
EN
15 kB
22 kB
50.00
0.02
25H
18H
25.00
0.04
51H
36H
16.67
0.06
76H
54H
12.50
0.08
102H
72H
8.33
0.12
153H
108H
6.25
0.16
204H
144H
1
5.00
0.20
255H
180H
1
4 17
0 24
306H
217H
1
54
English
ALARM REC MODE SET SETTING
Alarm trigger setting
1
Use the jog dial to move the cursor to the ALARM
TRIGGER setting.
2
Turn the shuttle dial clockwise, use the jog dial to select
the method of detecting suspicious people (example:
“SENSOR”), and then turn the shuttle dial.
The cursor moves to MOTION SENSOR.
Display examples: Alarm recording trigger settings
• ALARM: Alarm recording is carried out when an
external alarm (when a switch is connected to the
ALARM IN terminals at the rear of the unit for
open/close operation occurs).
• SENSOR: Alarm recording is only carried out when
the motion sensor detects a moving object. Refer to
motion sensor settings.
• ALARM AND SENSOR: Alarm recording is carried out
when there is a response from both an external
alarm and a built-in motion sensor.
• ALARM OR SENSOR: Alarm recording is carried out
when there is a response from either an external
alarm or a built-in motion sensor.
Note:
• MOTION SENSOR settings must be made if SENSOR, ALARM
AND SENSOR or ALARM OR SENSOR is selected.
• The digital video recorder’s built-in motion sensor cannot be
used if a multiplexer is connected to the digital video recorder.
• If using the built-in sensor of a multiplexer, the alarm output
should be directed to the alarm input of the digital video
recorder in order to record alarms.
• If you stop recording while alarm recording that has been
triggered by a motion sensor is in progress, move the cursor to
the ALARM REC MODE SET setting in menu 1 and then turn
the shuttle dial clockwise. The motion sensor screen appears,
so use this screen to change the LEVEL setting to “OFF”.
Built-in motion sensor settings
The monitor screen (-: 8x10) can be displayed on the monitor
screen so that detection of suspicious people (alarms) can be
carried out more easily. The default setting is for all motion sensors
to be “OFF”, so that they cannot detect the movement of objects.
Motion sensor screen
Use the jog dial to move the cursor to MOTION SENSOR, and then
turn the shuttle dial clockwise.
The motion sensor screen appears over the normal screen.
A When the sensors are set to “OFF” (-) and the shuttle dial is
turned clockwise, the sensor is changed to “ON” (ú). The
setting switches between “ON” and “OFF” each time the
shuttle dial is turned clockwise.
B When the jog dial is turned counterclockwise, the cursor
moves past “EXIT” and “LEVEL: OFF”, and then moves again
from the bottom to the top.
C When the jog dial is turned clockwise and the cursor reaches
the bottom, it moves past “LEVEL: OFF” and “EXIT” and then
moves to the top.
D The sensitivity can be adjusted when the sensor is set to “ON”
(ú). Turn the jog dial to select “LEVEL: OFF”, turn the shuttle
dial clockwise, and then turn the jog dial to adjust the
sensitivity.
(OFF 1 – 10: The sensitivity increases as the number
becomes lower.)
E If the cursor is at “EXIT” and the shuttle dial is turned
clockwise, the display returns to the ALARM REC MODE SET
screen.
PRE-ALARM RECORDING : ON
REC CYCLE : A0.24SEC. DURATION: 5SEC
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
PRE-ALARM RECORDING : ON
REC CYCLE : A0.24SEC. DURATION: 5SEC
=> (14298 ALARMS CAN BE RECORDED)
ALARM TRIGGER : SENSOR
MOTION SENSOR ->
-
ú
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : OFF EXIT
()
B
C
E
D
A
A
OFF (-)
ON (ú)
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : OFF
REC CYCLE : 0.12 SEC. DURATION: 5SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
English
55
ALARM REC MODE SET SETTING
1
Use the jog dial to move the cursor to the MOTION
SENSOR setting, and then turn the shuttle dial clockwise.
The motion sensor screen appears on the normal screen.
2
Turn the jog dial to set the sensor position, and then turn
the shuttle dial clockwise.
Since the sensor goes from OFF [-] to ON [ú], use the same
procedure to set the sensor ON.
3
Use the jog dial to move the cursor to “LEVEL: OFF”, turn
the shuttle dial clockwise, and then use the jog dial to set
the sensitivity (example: “6”).
Display examples: Sensitivity settings
• OFF: Sensor does not operate
• 1 to 10: Sensor operates (the lower the value, the greater
the sensitivity)
4
Turn the shuttle dial clockwise twice.
This completes the motion sensor settings, and the display is
returned to the ALARM REC MODE SET screen.
5
Press the EXIT/OSD button.
The display returns to the normal screen.
Note: Change the ALARM setting for the ALARM set item in the
BUZZER SET menu in MAIN MENU 2 to “ON”.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : OFF EXIT
PRE-ALARM RECORDING : ON
REC CYCLE : A0.24SEC. DURATION: 5SEC
=> (02415 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : OFF EXIT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : 6 EXIT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
ú
ú
ú
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : 6 EXIT
EXIT/OSD
56
English
DISPLAY SET SETTING
DISPLAY SET setting
The date and time that have been set using the CLOCK SET and
other settings can be displayed on the monitor screen during
recording and playback. The default setting is for all displays to be
“ON”, so all setting items in this menu appear on the screen. You
can turn the displays off if required.
1
Press the MENU button twice and display the MAIN MENU
2 screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
2
Turn the shuttle dial clockwise.
The DISPLAY SET sub-menu appears, and the cursor moves
to DATE.
3
Turn the shuttle dial clockwise.
“ON” flashes. If you use the jog dial to change it to “OFF”, the
date display disappears from the screen.
4
Turn the shuttle dial clockwise.
The cursor moves to TIME.
5
Turn the shuttle dial clockwise.
“ON” flashes. If you use the jog dial to change it to “OFF”, the
time display disappears from the screen.
6
If necessary, follow the same procedure (steps 3 and 4) to
change the ON/OFF settings.
• QUALITY (OFF): The picture quality mode does not
appear during recording and playback.
• REC CYCLE (OFF): The recording cycle does not
appear during recording and playback.
• ALARM COUNT (OFF): The current number of alarms
does not appear.
• ALARM TYPE (OFF): The type of alarm recording
does not appear.
Note:
• If ALARM RECORDING in the ALARM REC MODE SET menu
has been set to “OFF”, ALARM COUNT and ALARM TYPE do
not appear.
• When set to “ON”
• ALARM appears in the operating display during alarm
recording.
• PRE appears in the operating display during pre-alarm
recording.
• ARCHIVE appears when playing back images in the archive
area.
7
Press the EXIT/OSD button.
The display returns to the normal screen.
VIDEO LOSS SET setting
Use the jog dial to move the cursor to VIDEO LOSS, and then
turn the shuttle dial clockwise.
“ON” flashes. If the camera images are lost when this setting is
active, “VIDEO LOSS !” appears on the screen.
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
DATE : ON
TIME : ON
QUALITY : ON
REC CYCLE : ON
ALARM COUNT : ON
ALARM TYPE : ON
VIDEO LOSS : ON
Main menu 2
Sub-menus
Displays the date on the monitor screen.
Displays the time on the monitor screen.
Displays the image quality on the monitor
screen.
Displays the recording rate (recording
speed) on the monitor screen.
Displays the number of alarms on the
monitor screen.
Displays the alarm types on the monitor
screen.
For an example of the display, please refer to
the operating display section. (See page 11.)
MENU
DATE : ON
TIME : ON
QUALITY : ON
REC CYCLE : ON
ALARM COUNT : ON
ALARM TYPE : ON
VIDEO LOSS : ON
EXIT/OSD
English
57
RS-232C/RS-485 SET SETTING
RS-232C/RS-485 SET setting
Settings related to RS-232C and RS-485 serial communication.
1
Press the MENU button twice to display the MAIN MENU 2
screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
2
Use the jog dial to move the cursor to the
RS-232C/RS-485 SET settings, and then turn the shuttle
dial clockwise.
The RS-232C/RS-485 SET sub-menu appears, and the cursor
moves to CONTROL.
3
Turn the shuttle dial clockwise.
“RS-232C” flashes. Use the jog dial to select either RS-232C
or RS-485.
RS-232C Selection
For connection of the RS-232C terminal of the unit to a computer,
please use a special RS-232C cable (sold separately). (See page
7.)
1
Turn the jog dial to select RS-232C, and then turn the
shuttle dial clockwise.
The cursor moves to DATA SPEED.
2
Turn the shuttle dial clockwise, use the jog dial to select a
communication speed (example: “19200”), and then turn
the shuttle dial clockwise.
This completes the setting and the cursor moves to
CONTROL.
• Communication speeds: 2400, 4800, 9600 and 19200
3
Press the EXIT/OSD button.
The display returns to the normal screen.
CONTROL : RS-232C
DATA SPEED : 19200
STATUS INFO : ***
ALARM INFO : ***
ADDRESS : ***
Main menu 2
Sub-menus
Selects CONTROL.
Sets communication environment.
Setting for RS-485 only
• Enables transmission of status.
• Enable transmission of alarm.
• Sets address.
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
1.DISPLAY SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
CONTROL : RS-232C
DATA SPEED : 19200
STATUS INFO : ***
ALARM INFO : ***
ADDRESS : ***
CONTROL : RS-232C
DATA SPEED : 19200
STATUS INFO : ***
ALARM INFO : ***
ADDRESS : ***
CONTROL : RS-232C
DATA SPEED : 19200
STATUS INFO : ***
ALARM INFO : ***
ADDRESS : ***
CONTROL : RS-232C
DATA SPEED : 19200
STATUS INFO : ***
ALARM INFO : ***
ADDRESS : ***
EXIT/OSD
58
English
RS-232C/RS-485 SET SETTING
RS-485 Selection
Connect the RS-485 control terminals (A and B) of the digital video
recorder in series with other devices such as a controller,
multiplexer or another digital video recorder. (See page 7.)
1
Turn the shuttle dial clockwise, use the jog dial to select
RS-485, and then turn the shuttle dial clockwise.
The cursor moves to DATA SPEED.
The STATUS INFO, ALARM INFO and ADDRESS settings
can be changed.
2
Turn the shuttle dial clockwise, use the jog dial to select a
communication speed (example: “19200”), and then turn
the shuttle dial clockwise.
• Communication speeds: 2400, 4800, 9600 and 19200
The cursor moves to STATUS INFO.
3
Turn the shuttle dial clockwise, use the jog dial to select
status information (example: “ON”), and then turn the
shuttle dial clockwise.
• ON: Status information will be transmitted.
The cursor moves to ALARM INFO.
4
Turn the shuttle dial clockwise, use the jog dial to select
alarm information (example: “ON”), and then turn the
shuttle dial clockwise.
• ON: Alarm information will be transmitted.
The cursor moves to ADDRESS.
5
Turn the shuttle dial clockwise, use the jog dial to select
an address (example: “37”), and then turn the shuttle dial
clockwise.
This completes the setting and the cursor moves to
CONTROL.
Note: The range of valid addresses for this unit is from 0 to 127. If
more than one digital video recorder is connected, be careful
that same addresses are not repeated.
• Address item: 0 to 127
6
Press the EXIT/OSD button.
The display returns to the normal screen.
CONTROL : RS-485
DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 000
CONTROL : RS-485
DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 000
CONTROL : RS-485
DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 37
CONTROL : RS-485
DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 000
EXIT/OSD
English
59
BUZZER SET SETTING
The buzzer can be made to sound as a warning during an alarm
and when the hard disk becomes full.
1
Press the MENU button twice and display the MAIN MENU
2 screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
2
Use the jog dial to move the cursor to the BUZZER SET
setting, and then turn the shuttle dial clockwise.
The BUZZER SET sub-menu appears, and the cursor moves
to ALARM.
3
Turn the shuttle dial clockwise.
“OFF” flashes. Use the jog dial to change the setting to “ON”
or “OFF”.
ON: The buzzer will sound when an alarm is triggered.
4
If necessary, follow the same procedure to change the
buzzer setting (ON/OFF).
• DISK FULL (ON):
Sets whether the buzzer sounds when disk overwriting is off
and the hard disk is nearly full.
• DISK ERROR (ON):
Sets whether the buzzer sounds when there is a hard disk
error.
• LOCK WARNING (ON):
When the security lock is engaged and a locked button is
pressed, the buzzer sounds.
Note: When an item is set to “ON”, the buzzer sounds twice
at an interval of about 0.5 seconds.
• KEY IN (ON):
Sets the buzzer to sound each time an operating button is
pressed.
• NON REC (ON):
Sets the buzzer to sound when recording stops by itself and
when another person deliberately stops recording.
5
Press the EXIT/OSD button.
The display returns to the normal screen.
ALARM : OFF
DISK FULL : ON
DISK ERROR : ON
LOCK WARNING : ON
KEY IN : OFF
NON REC : OFF
Main menu 2
Sub-menus
Sets the buzzer to sound during alarms.
Sets the buzzer to sound when there is
no recording space left.
Sets the buzzer to sound when there is a
problem with the hard disk.
Sets the buzzer to sound when the
security lock is engaged.
Sets the buzzer to sound when an
operating button is pressed.
Sets the buzzer to sound when not
recording.
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
ALARM : OFF
DISK FULL : ON
DISK ERROR : ON
LOCK WARNING : ON
KEY IN : OFF
NON REC : OFF
EXIT/OSD
60
English
SECURITY LOCK SET SETTING
Passwords for this digital video recorder can be set by the Administrator or the User or both. Setting passwords enables privileges to be set for
recording and playback operations. After the security lock has been set, if someone other than the password setter touches an operating button
on the unit, the buzzer will sound and a password must be entered. Therefore, be sure to make a note of the password.
Operating privileges and security lock
A Administrator password setting
Example: To set the password to “123456AB”
1
Press the MENU button twice to display the MAIN MENU 2
screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
2
Use the jog dial to move the cursor to the SECURITY
LOCK SET setting, and then turn the shuttle dial
clockwise.
The SECURITY LOCK sub-menu appears, and the cursor
moves to ADMIN.
Note:
• “LEVEL PASSWORD (4-8) USE” is a title and cannot be
changed.
• If ADMIN is set to “OFF”, the user password cannot be set.
• The password can consist of between four and eight
alphanumeric characters.
3
Turn the shuttle dial clockwise.
The first password entry bar flashes.
4
Use the jog dial to display “1”, and then turn the shuttle
dial.
The second password entry bar flashes.
• The characters that can be used in the password are: 0, 1,
... 9, A, B, C, ... Z
5
Use the jog dial to display “2”, and then turn the shuttle
dial.
The third password entry bar flashes.
6
Repeat this procedure to continue entering “3456AB”,
and then turn the shuttle dial clockwise.
The cursor moves to “OFF” and flashes.
LEVEL PASSWORD(4-8) USE
ADMIN -------- OFF
USER -------- OFF
REC CONTROL : ADMIN
Main menu 2
Sub-menus
Sets the Administrator level and User
level security locks.
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
LEVEL PASSWORD(4-8) USE
ADMIN -------- OFF
USER -------- OFF
REC CONTROL : ADMIN
ADMIN -------- OFF
ADMIN 1------- OFF
ADMIN 12------ OFF
LEVEL PASSWORD(4-8) USE
ADMIN 123456AB OFF
USER -------- OFF
REC CONTROL : ADMIN
English
61
SECURITY LOCK SET SETTING
7
Use the jog dial to change the setting to “ON”, and then
turn the shuttle dial clockwise.
The cursor moves to USER.
8
Set User password.
Carry out B User password setting. If the User setting is
not to be done, this is complete.
Use the jog dial to move the cursor to REC CONTROL and
carry out the recording and playback operating privilege
setting. (See page 63.)
Note: If setting a 4-character password, leave the 5th character as
"-" and then turn the shuttle dial clockwise.
B User password setting
Example: To set the password to “AB123456”
1
Use the jog dial to move the cursor to USER, and then
turn the shuttle dial clockwise.
The first password entry bar flashes.
2
Use the jog dial to display “A”, and then turn the shuttle
dial.
The second password entry bar flashes.
• The characters that can be used in the password are: 0, 1,
... 9, A, B, C, ... Z
3
Use the jog dial to display “B”, and then turn the shuttle
dial.
The third password entry bar flashes.
4
Repeat this procedure to continue entering “123456”, and
then turn the shuttle dial clockwise.
The cursor moves to “OFF” and flashes.
5
Use the jog dial to change the setting to “ON”, and then
turn the shuttle dial clockwise.
The cursor moves to REC CONTROL.
Carry out the recording and playback operating privilege
setting. (See page 63.)
LEVEL PASSWORD(4-8) USE
ADMIN 123456AB ON
USER -------- OFF
REC CONTROL : ADMIN
USER -------- OFF
USER A------- OFF
USER AB------ OFF
LEVEL PASSWORD(4-8) USE
ADMIN 123456AB ON
USER AB123456 OFF
REC CONTROL : ADMIN
LEVEL PASSWORD(4-8) USE
ADMIN -------- OFF
USER AB123456 ON
REC CONTROL : ADMIN
62
English
SECURITY LOCK SET SETTING
C Recording and playback operating privilege
setting
Selection of operating privilege
The available operations vary depending on the ON/OFF and
ADMIN/USER settings.
Selection
conditions
Details of operation
All operations are locked. When the user password
is entered at the password entry screen, only
playback operations can be carried out. When the
Administrator password is entered, all operations
can be carried out.
All operations are locked. When the user password
is entered at the password entry screen, only
playback and recording operations can be carried
out. When the Administrator password is entered,
all operations can be carried out.
Recording and menu operations are locked.
Playback operations are not locked. When the
Administrator password is entered, all operations
can be carried out.
Menu operation is locked. Recording and playback
operations are not locked. When the Administrator
password is entered at the password entry screen,
all operations can be carried out.
Security lock is not engaged (default setting).
Security lock is not engaged (default setting).
1
Use the jog dial to move the cursor to REC CONTROL.
2
Turn the shuttle dial clockwise, and then use the jog dial
to select “ADMIN” or “USER”.
This completes the setting.
3
Press the EXIT/OSD button.
The display returns to the normal screen.
D Security lock setting
1
At the normal monitoring screen, press and hold the
SUHTTLE HOLD button for approximately 3 seconds.
The LOCK indicator at the front panel illuminates and the
buzzer sounds. The security lock is then set.
2
Press any operating button to check the security lock.
The password entry screen appears.
The screen display disappears after 5 seconds.
3
Use the jog dial and the shuttle dial to enter the
password, and then turn the shuttle dial clockwise once
more.
The LOCK indicator goes off and the display returns to the
normal screen.
Note: Enter the password (example: “123456AB”) that was
entered as the Administrator or User password setting.
LEVEL PASSWORD(4-8) USE
ADMIN 123456AB ON
USER AB123456 ON
REC CONTROL : ADMIN
ADMIN 123456AB ON
USER AB123456 ON
REC CONTROL : USER
ADMIN 123456AB ON
USER -------- OFF
REC CONTROL : ADMIN
ADMIN 123456AB ON
USER -------- OFF
REC CONTROL : USER
ADMIN -------- OFF
USER -------- OFF
REC CONTROL : ADMIN
ADMIN -------- OFF
USER -------- OFF
REC CONTROL : USER
LEVEL PASSWORD(4-8) USE
ADMIN 123456AB ON
USER AB123456 ON
REC CONTROL : ADMIN
LOCK
LEVEL PASSWORD(4-8) USE
ADMIN 123456AB ON
USER AB123456 ON
REC CONTROL : ADMIN
LOCK
EXIT/OSD
LOCK
SHUTTLE HOLD
POWER
FULL
ALARM FULL
LOCK
LOCK
REC/STOP
LOCK
SECURITY LOCKED !
PLEASE ENTRE YOUR PASSWORD
--------
CHANGE WITH JOG. SET WITH SHUTTLE
SECURITY LOCKED !
PLEASE ENTRE YOUR PASSWORD
********
CHANGE WITH JOG. SET WITH SHUTTLE
LOCK
1
2
3
English
63
NETWORK SET SETTING
NETWORK SET setting
1
Insert a LAN card or a PCMCIA-compatible Ethernet card
(sold separately) into the PC card slot at the rear of the
digital video recorder.
This will enable you to view images on this unit and make
menu settings through the network (LAN) from a personal
computer. ID1, ID2 and ID3 passwords are required.
Note: A PCMCIA card-type LAN card (sold separately) and an
Ethernet cable are necessary in order to connect to a
network.
2
Press the MENU button twice to display the MAIN MENU 2
screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
3
Use the jog dial to move the cursor to the NETWORK SET
setting, and then turn the shuttle dial clockwise.
The NETWORK SET sub-menu appears, and the cursor
moves to LAN CARD.
4
Turn the shuttle dial clockwise.
“LAN1” flashes.
Select LAN1 or LAN2 to suit the type of card being used.
• LAN1: COREGA FEther PCC-TXD “CG-FEPCCTXD” type
(10/100 BASE-T)
• LAN2: COREGA Ether PCC-TD “CG-EPCCTD” type (10
BASE-T) or COREGA Ether II PCC-T (10 BASE-T)
or D-Link DE-660
Note: Correct operation cannot be guaranteed if a LAN card other
than the one recommended above is used.
5
Use the jog dial to select the LAN card (example:
“LAN1”), and then turn the shuttle dial clockwise.
The cursor moves to NETWORK CONTROL.
LAN CARD : LAN1
NETWORK CONTROL : OFF
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PASSWORD SETTING
ID : PASSWORD (4-8)
ID1 : 1111----
ID2 : 2222----
ID3 : 3333----
Main menu 2
Sub-menus
Sets LAN card.
Sets network control.
Enter IP ADDRESS.
Enter SUBNET MASK.
Enter GATEWAY.
Sets the three levels of user passwords.
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
1
2
3
1
3
2
(Installed)
(Removed)
Locking can be
carried out easily
by sliding the
knob.
Return the knob
after unlocking.
MENU
LAN CARD : LAN1
NETWORK CONTROL : OFF
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PASSWORD SETTING
ID : PASSWORD (4-8)
GUEST : 1111----
USER : 2222----
ADMIN : 3333----
LAN CARD : LAN1
NETWORK CONTROL : OFF
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PASSWORD SETTING
64
English
NETWORK SET SETTING
6
Turn the shuttle dial clockwise and use the jog dial to
select network control (example: “ON”), and then turn the
shuttle dial clockwise.
The cursor moves to IP ADDRESS.
Note:
• Control through the network is not possible unless NETWORK
CONTROL is ON.
When you are connected to a network, it should be switched
OFF if control from the network is not required.
• If DIGITAL SERIES RECORDING in the RECORDING
CONDITIONS SET menu is set to “ON”, NETWORK CONTROL
cannot be set to “ON”.
7
Turn the shuttle dial clockwise and use the jog dial and
shuttle dial to display the IP ADDRESS (example:
“192.168.0.1”), and then turn the shuttle dial clockwise.
With the final shuttle dial movement, the cursor moves to
SUBNET MASK.
8
Turn the shuttle dial clockwise and use the jog dial and
shuttle dial to display the SUBNET MASK (example:
“255.255.255.0”), and then turn the shuttle dial clockwise.
With the final shuttle dial movement, the cursor moves to
GATEWAY.
9
Turn the shuttle dial clockwise and use the jog dial and
shuttle dial to display the GATEWAY (example:
“192.168.0.1”), and then turn the shuttle dial clockwise.
With the final shuttle dial movement, the cursor moves to ID1
under PASSWORD SETTING.
Note: When connecting this unit to a network, check the IP
ADDRESS, SUBNET MASK and GATEWAY settings with
the LAN Network Administrator.
PASSWORD SETTING setting
For network connection there are three access levels, each of
which has a password. Each password can consist of a
combination of 4 to 8 alphanumeric symbols.
Note: The cursor cannot be moved to ID or PASSWORD (4-8).
Example: Set AB123456 as the ID1 password.
1
Use the jog dial to move the cursor to ID1, and then turn
the shuttle dial clockwise.
The initial digit 1 of the password entry flashes.
• The characters that can be used in the password are: 0, 1
... 9, A, B ... Z
Note:
• ID1: This level can only observe a live image through the
network.
• ID2: This level can observe a live image and play back and
search recorded images through the network.
• ID3: This level allows all digital video recorder operations and
settings to be carried out.
2
Use the jog dial to display “A”, and then turn the shuttle
dial.
The second digit 1 flashes.
3
Use the jog dial to display “B”, and then turn the shuttle
dial.
The third digit 1 flashes.
LAN CARD : LAN1
NETWORK CONTROL : ON
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PASSWORD SETTING
LAN CARD : LAN1
NETWORK CONTROL : ON
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PASSWORD SETTING
LAN CARD : LAN1
NETWORK CONTROL : ON
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PASSWORD SETTING
PASSWORD SETTING
ID : PASSWORD (4-8)
ID1 : 1111----
ID2 : 2222----
ID3 : 3333----
ID1 : A111----
ID1 : AB11----
English
65
NETWORK SET SETTING
4
Repeat this procedure to continue entering “123456”, and
then turn the shuttle dial clockwise.
The cursor moves to ID2.
5
As required, use the same procedure to set passwords
for ID2 and ID3, and then turn the shuttle dial clockwise.
The cursor moves to LAN CARD.
6
Press the EXIT/OSD button.
The display returns to the normal screen.
PASSWORD SETTING
ID : PASSWORD (4-8)
ID1 : AB123456
ID2 : 2222----
ID3 : 3333----
EXIT/OSD
66
English
HDD SET SETTING
HDD SET setting
To display hard disk capacity in DISK1 (on board) and DISK2 (for
addition)
Note: Before adding a hard disk, it is important to backup recorded
images on a media such as a CompactFlash card.
1
Press the MENU button twice to display the MAIN MENU 2
screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
2
Use the jog dial to move the cursor to the HDD SET
settings, and then turn the shuttle dial clockwise.
The HDD SET sub-menu appears, and the cursor moves to
DISK INITIALIZE.
3
Turn the shuttle dial clockwise.
A WARNING screen appears and then “NO” flashes.
4
Use the jog dial to select YES, and then turn the shuttle
dial.
The “HDD INITIALIZING!” screen appear and the hard disk is
initialized. Then the display is returned to the HDD SET
screen.
5
Press the EXIT/OSD button.
The display returns to the normal screen.
Adding a hard disk
Consult your dealer about adding a hard disk. In the case of an
addition, use an additional hard disk unit (sold separately).
If adding another hard disk, be sure to initialize the hard disks.
When this is done, both hard disks will be initialized, so that any
existing data on the original hard disk will be cleared.
Reference: HDD SET screen
• MIRRORING: When a hard disk is added, it is possible to
record the same image on two hard disks. This means that
even if an image write error occurs you will be able to read from
an area where there is no write error. Note that if mirroring is
specified, the upper limit of recording speed will be limited.
• PLAYBACK DRIVE: After MIRRORING has been set, you will
be able to specify which of the two hard disks is to be used for
reading the recorded image.
With mirroring setting, if an error has occurred in the playback
image, switch from the hard disk in current use (DISK1) to
(DISK2).
DISK1 : 80GB
DISK2 : ---GB
DISK INITIALIZE ->
CAUTION : ALL RECORDING WILL BE ERASED!
MIRRORING : OFF
PLAYBACK DRIVE : ¤¤¤
CAUTION : RECORDING SPEED WILL BE
LIMITED BY MIRRORING!
Main menu 2
Sub-menus
Initializes hard disk.
Records mirroring.
Sets the hard disk reading.
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
MENU
DISK1 : 80GB
DISK2 : ---GB
DISK INITIALIZE ->
CAUTION : ALL RECORDING WILL BE ERASED!
MIRRORING : OFF
PLAYBACK DRIVE : ***
CAUTION : RECORDING SPEED WILL BE
LIMITED BY MIRRORING!
THIS CHANGE WILL INITIALIZE THE DISK.
ALL RECORDING WILL BE ERASED.
ARE YOU SURE ?
NO
CHANGE LINES WITH JOG. SELECT WITH SHUTTLE
HDD INITIALIZING !
EXIT/OSD
English
67
POWER FAILURE/USED TIME DISPLAY
1
Press the MENU button twice to display the MAIN MENU 2
screen.
The cursor moves to DISPLAY SET/VIDEO LOSS SET.
2
Use the jog dial to move the cursor to the POWER
FAILURE/USED TIME settings, and then turn the shuttle
dial clockwise.
The POWER FAILURE/USED TIME sub-menu appears.
Check the date/time of a power failure or the usage time of
hard disks, etc.
3
Press the EXIT/OSD button.
The display returns to the normal screen.
About the sub-menu
1 FAILURE
Shows the date/time when a power failure occurred.
The number of power failures appears at the left. (example:
#020) When the number exceeds 999 it returns to 000.
2 RECOVER
Shows the date/time when power was restored.
3 DISK1 USE
Shows the total hard disk 1 usage time.
4 DISK2 USE
Shows the total hard disk 2 usage time.
5 POWER
Shows the total usage time for this unit.
POWER FAILURE
#020 FAILURE ----- --:--
RECOVER ----- --:--
USED TIME
DISK1 USE : 00000H
DISK2 USE : -----H
POWER : 00000H
1.DISPLAY SET/VIDEO LOSS SET ->
2.RS-232C/RS-485 SET ->
3.BUZZER SET ->
4.SECURITY LOCK SET ->
5.NETWORK SET ->
6.HDD SET ->
7.POWER FAILURE/USED TIME ->
TO MAIN MENU 1 ->
MOVE LINES WITH JOG. SELECT WITH SHUTTLE
Main menu 2
Sub-menus
12
34
5
MENU
POWER FAILURE
#001 FAILURE 15-06 20:30
RECOVER 15-06 21:30
USED TIME
DISK1 USE : 00060H
DISK2 USE : -----H
POWER : 00060H
EXIT/OSD
68
English
9-pin connector specifications
Pin No.
Signal
Operation
Signal direction
1
–
–
–
2
RXD
Receive data
Computer → Digital video recorder
3
TXD
Transmit data
Digital video recorder → Computer
4
–
–
–
5
GND
Ground
–
6
–
–
–
7
RTS
Request to send
Digital video recorder → Computer
8
–
–
–
9
–
–
–
Data format
Mode
Asynchronous
Character length
8 bits
Data transmit speed
2400, 4800, 9600, 19200 bps
Parity
None
Stop bit
1
Communication protocol
Communication is carried out in units of 1 byte. After the computer transmits one byte of data, it waits for a
response from the digital video recorder, and then transmits the next byte of data.
To start sending commands, an ON (F6) command is sent. The digital video recorder will continue to receive
commands until an OFF (F7) command is sent to stop. The digital video recorder sends an ACK (OA) each time it
receives a command.
See Table 4 - Command Table on page 71.
RS-485
Data format
Mode
Asynchronous
Character length
8 bits
Data transmit speed
2400, 4800, 9600, 19200 bps
Parity
None
Stop bit
1
Communication protocol
A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It is recommended that a special controller be
used. Contact the place of purchase for further details on obtaining a special controller.
9
8
7
6
5
4
3
2
1
English
69
Termination setting
If several unit are being connected together, termination settings must also be made.
• Set the RS485 termination switch on the rear panel to ON, and set the termination switch of the last device in the series to ON.
• Be sure to set the RS485 termination switches of all devices in between (devices other than the first and last in the series) to OFF.
Note: If the termination settings are not correct, data will be reflected by either end of the series and this will affect the transmission of other
data, so that the data that is transmitted to each device will not be correct.
(Example)
System controller
Multiplexer
Digital video recorder
Termination switch
Time lapse VCR
12V DC IN
POWER
ON
OFF
RS485
GND
1
0
A
A
B
B
ADDRESS
TERMINATE
1 2 3
OFF
ON
OFF
TERMINATE
ON
RS485
OFF
ON
Termination switch
OFF
ON
RS485
TERMINATE
70
English
Command Table (Table 4)
The following table shows all of the commands that can be processed by the digital video recorder.
If a command sent does not correspond to a digital video recorder function, the command is received but no operation is carried out.
Upper bit
0
1
2
3
4
5
6
7
Lower bit
0
TIMER
ON/OFF
1
2
3
SHIFT←
SHIFT→
4
SHIFT↑
SHIFT↓
MENU
5
SHIFT+
/RP UP
6
SHIFT–
/RP DOWN
7
8
9
SECURITY
LOCK ON
A
ACK
PLAY
REV PLAY/
SEARCH
(DVR)
B
NAK
C
GROUP SET
D
GROUP
CHECK
E
GROUP
CLEAR
F
STOP
STILL
Upper bit
8
9
A
B
C
D
E
F
Lower bit
0
CLOCK
ADJUST
1
MENU RESET
2
3
4
5
ZOOM (MPX)
6
7
STATUS
SENSE
8
MENU
UPLOAD
MENU
DOWNLOAD
9
CLOCK
DOWNLOAD
A
REC
REC/DUB
REQUEST
B
FF/ALARM F
C
CHANNEL
REW/ALARM
R
D
COPY
*RS-485
SEND START
E
OSD/EXIT
STATUS
LOG2
*RS-485 RCV
CMF.
F
STATUS
LOG1
REC STOP
: Command for RS-485 only.
English
71
Hard disk capacity
: 80 GB (Installation of additional hard disk 80 GB (sold separately) possible)
Television System
: Based on PAL colour signal standard
Picture Resolution
: 720 x 288 (Field),720 x 576 (Frame)
Compression
: M-JPEG
Picture Quality
: 5 Levels (Basic, Normal, Enhanced, Fine, Super Fine)
Recording Type
: Frame or Field Recording
Recording Speed
: 27 Levels.
Recording Area
: Normal Recording Area, Alarm Recording Area, Archive Area
Playback
: Playback, Still, Search
Zoom
: 2 Times Zoom Function
Search Mode
•••• Time/Date Search
: Search by time and date
•••• Alarm Search
: Search by alarm event list
•••• Alarm Thumbnail Search
: Search by alarm event thumbnails
•••• Archive Area Search
: Search Archive Area with event list
•••• Smart Motion Search
: Search by specifying a motion sensor
Menu Language
: English/French/German/Spanish
Video input terminal
: 1.0 Vp-p/75 Ω, unbalanced, BNC x 1
S- video input terminal
: Separate YC signals, DIN connector (S terminal) x 1
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.300 Vp-p/75 Ω, unbalanced
Digital input terminal
: RJ-45 x 1
Digital SUB input terminal
: RJ-45 x 1
Audio input terminal
: –8dBs, 27 kΩ unbalanced, RCA pin jack x 1
Microphone input terminal
: –60dBs 10kΩ unbalanced, 3.5mm mini jack
Video output terminal
: 1.0 Vp-p/75 Ω, unbalanced, BNC x 1
S- video output terminal
: Separate YC signals, DIN connector (S terminal) x 1
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.300 Vp-p/75 Ω, unbalanced
Loop out terminal
: 1.0 Vp-p/75 Ω, unbalanced, BNC x 1
S- video loop out terminal
: Separate YC signals, DIN connector (S terminal) x 1
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.300 Vp-p/75 Ω, unbalanced
Digital output terminal
: RJ-45 x 1
Digital SUB output terminal
: RJ-45 x 1
Audio output terminal
: –8dBs, 600 Ω unbalanced, RCA pin jack x 1
Compact Flash Slot
: Compact Flash Type 2 (Front)
PC Card Slot
: PCMCIA Type 2 (Rear) for SCSI or Ethernet card
RS-232C terminal
: D- SUB 9pin (for PC)
Control connectors
•••• RS-485 terminal
: Push lock (3 terminals: A, B, C (GND))
•••• Remote Control terminal
: 1 input for resister alley switch
•••• Alarm in terminal
: 1 input (Normal Open Low level active)
•••• Alarm out terminal
: 1 output (Normal 5V Low level active)
•••• Alarm reset terminal
: 1 input (Normal Open Low level active)
•••• SW out terminal
: 1 output (Normal 5V Low level active)
•••• NON Rec out terminal
: 1 output (Normal 5V Low level active)
•••• Clock Adjust in terminal
: 1 input (Normal Open Low level active)
•••• Clock Adjust out terminal
: 1 output (Normal 5V Low level active)
•••• Warning out terminal
: 1 output (Normal 5V Low level active)
•••• Disk Full out terminal
: 1 output (Normal 5V Low level active)
•••• Alarm Full out terminal
: 1 output (Normal 5V Low level active)
Power
: AC 220 – 240 V, 50 Hz
Power consumption
: 27 W 260 mA
Operating environment
: Temperature: 5°C to 40°C, Humidity: 10 to 80%
Dimensions
: 420 (W) x 86 (H) x 364.5 (D) mm
Weight
: Approx. 5.5 kg
Products are subject to change in design and specifications without notice and without incurring any obligation.
72
English
Product usage manual for the Luma Surveillance 501 Series Security System. It contains information on repair references, functional overview, security instructions, software configuration.
Manual for installation and usage of the Philips DS9000 Other. The manual provides technical details on device safety checks, menu navigation, basic operation, device reset instructions.
Product documentation for the Optimum Multi-Room DVR DVR. This guide offers guidance on setup guidelines, regulatory notices, performance optimization, energy usage.