Sanyo VDC-DP9584S Installation Manual
| Brand: | Sanyo |
| Category: | Security Camera |
| Model: | VDC-DP9584S (Installation Manual) |
| File Type: | |
| File Size: | 0.58 Mb |
| Pages: | 8 |
Text of Sanyo VDC-DP9584S Installation Manual
Sanyo VDC-DP9584S Color CCD Camera
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED
SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL
CODES.
Please read this manual before installing and using this unit, and always follow the instructions
in it for proper use. Please also read the separate INSTRUCTION MANUAL before using the unit
for proper use.
This unit can be installed on the ceiling or wall.
When installing, first remove the built-in camera
from the unit
Installing on the Ceiling
1 Loosen the four screws (A) using the
hexagonal wrench (large) and open the
dome cover.
2 Unplug the pin connector cables from
the circuit board.
3 While holding the chassis (B), pull out
the sliding plate (C) in the arrowed
direction.
The locks (D) on the base chassis come off
and free the camera unit.
1 Attach the cushioning sheet (F) to the
back of the camera unit base (G), open a
cable hole in the cushioning sheet, and
pass
1 Connect the cables from the ceiling.
Push the excess of connected cables into
the ceiling.
For details on the connections, see page 5.
2 Free the locks (E) on the base chassis.
3 Mount the camera unit using the two
base screws (J).
4 Push the sliding plate (D) in the arrowed
direction until it clicks, then connect the
pin connector cables from the camera
unit base to the circuit board.
The sliding plate must be between the
screws (K) and the base chass
Installing on the Wall
See “Installing on the Ceiling” (see page 1).
• Work with the locks on the sliding plate set
free.
1 Push the spring (A) and set free the hooks
from the base chassis. Lift and turn the
camera in the arrowed directions so that
the back of the camera becomes visible.
2 Rotate the camera so that the position of
the locks (B) is upside down.
3 Align the locks (B) with the slots (C) on
the base chassis, push the spring (A),
and mo
2 Free the locks (G) on the base chassis.
3 Mount the camera unit using the two
base screws (H).
4 Push the sliding plate (J) in the arrowed
direction until it clicks, then connect the
pin connector cables from the camera
unit base to the circuit board.
The sliding plate must be between the
screws (K) and the base chassis for its
ends to be locked.
5 Peel off the release-coated paper of the
cover sheet and cover the back of the
camera completely with the
Sanyo VDC-DP9584S RG-6U, 300 m or less
For the connection, use a RG-6U coaxial
cable.
Monitor Connection
b With AC 24 V
Power Supply Connection
• Using different cables from those
specified here may attenuate the
video and/or sync signals and
interfere with correct transmission.
• RG-59U coaxial cables can be
used whe
6
CAMERA
PRESET POSITION
AUTO MODE
AUTO RETURN
·ALARM
PASSWORD
LANGUAGE
OPTION
PRESET
MENU
SET y
1 y
SEQ y
SET y
SET y
SET y
SET y
SET y
OFF
END
ALARM SETTING
·ALARM IN
ALARM OUT
MOTION
uAREA
uSENSITIVITY
ZOOM
1 y
NO
OFF
SET y
SET y
OFF
ALARM SETTING
ALARM IN
·ALARM OUT
MOTION
uAREA
1 y
NO
OFF
SET y
SYNC
BLC
IRIS
WHITE BALANCE
AGC GAIN
GAMMA
SHUTTER
APERTURE
·DAY/NIGHT
PRESET
MENU
INT
OFF
SET y
A
Sanyo VDC-DP9584S Adjusting the Camera
bSetting up the camera remotely
Use of the separately ordered Camera Control Unit (VAC-70) is recommended for setting and adjustment of
this camera. The Camera Control Unit allows you to adjust the camera angle (pan/tilt) as well as perform
advanced settings from the main menu. For details, see the instruction manual for the Camera Control Unit.
bInstallation accessories
Do not forget to disconnect the Camera Control Unit once you ha