Scotsman MCM1462 Service Manual
Text of the manual
To the owner or user: This service manual is
intended to provide you and the maintenance or
service technician with the information needed to
install, start up, clean, maintain and service this
ice system.
Table of Contents
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions (w/o bin)
W" x D" x H"
Basic Electrical
Minimum Circuit
Ampacity*
Maximum
Fuse Size
Refrigerant
Charge
Condenser
Type
MCM1462AS-3A
48 x 243⁄8 x 271⁄2
208-230/60/3
20.2
20
60 oz. R-22 Air
MCM1462WS-3A
48 x 243⁄8 x 271⁄2
208-230/60/3
19.5
20
64 oz. R-22 Water
* Minimum Circuit Ampacity is used to determine wire size and type p
FOR THE INSTALLER: Location & Assembly
Location:
After uncrating and inspection, the unit is ready for
installation. It is important that the machine be
installed in a location where it has enough space
around it to be accessible for service. A minimum
of 6" must be allowed at the back for air circulation
on air cooled models. Try to avoid hot, dirty and
cro
FOR THE INSTALLER: Location & Assembly
Stacking Instructions
A stacking kit, KSMCM48, is required to
interconnect the ice level controls, seal the
freezing compartments, support the bin with heavy
duty legs, and to retain the top edges of the
bottom unit’s front panels.
Follow the installation instructions of the stacking
kit, but in general:
Before addin
FOR THE ELECTRICIAN
SEE NAMEPLATE for current requirements to
determine wire size to be used for electrical
hookup. The cuber requires a solid chassis to
chassis earth ground wire. See Wiring Diagram.
Be certain the cuber is connected to its own
electrical circuit and individually fused. Voltage
variation should not exceed ten percent of the
nameplate ratin