Seagate Cheetah 10K.6 SCSI Installation Manual

Specifications

Brand: Seagate
Category: Storage
Model: Cheetah 10K.6 SCSI (Installation Manual)
File Type: PDF
File Size: 0.21 Mb
Pages: 2

Read Online

Read the Seagate Cheetah 10K.6 SCSI Installation Manual online using the built-in PDF viewer.

Text of the manual

Cheetah 10K.6 SCSI Installation Guide

ST3146807LW/LC, ST373307LW/LC, ST336607LC/LW Publication Number: 100195488, Rev. B, June 2002 Handling precautions/Electrostatic discharge protection • Disc drives are fragile. Do not drop or jar the drive. Handle the drive only by the edges or frame. • Drive electronics are extremely sensitive to static electricity. Keep the drive in its antistatic container until you are ready to install it. Wear a wrist strap and cable connected to ground. Discharge static from all items near or that will contact the drive. Never use an ohmmeter on any circuit boards. • Turn off the power to the host system during installation. • Always use forced-air ventilation when operating the drive. • Use caution when troubleshooting a unit that has voltages present. • Do not disassemble the drive; doing so voids the warranty. • Return the entire drive for depot service if any part is defective. • Do not apply pressure or attach labels to circuit board or drive top. Electromagnetic compliance See Safety and Regulatory Agency Specifications, p/n 75789512. Drive characteristics ST3146807 ST373307 ST336607 LW/LC LW/LC LW/LC Formatted capacity 146.80 Gbytes 73.40 Gbytes 36.70 Gbytes Total # of data blocks 286,749,488 143,374,744 71,687,372 (11177330h) (88BB998h) (445DCCCh) Cylinders (user accessible) 49,855 49,855 49,855 Heads (user accessible) 8 4 2 Disc rotation ± 5% 10,008 RPM 10,008 RPM 10,008 RPM Operating voltages +5V +12V +5V +12V +5V +12V Typical operating current (amps) 1.00 0.95 0.89 0.80 0.92 0.68 What you need • Screwdriver and four 6-32 UNC drive mounting screws • Forced-air ventilation to provide adequate drive cooling • An unused drive power connector (not applicable to LC models) To operate at LVD transfer rates, you may also need an LVD-capable SCSI host adapter, LVD I/O cable and active negation external terminator. Multimode interface This drive can operate in single-ended (SE) or low voltage differential (LVD) mode. This multimode capability provides backwards compatibility so you can use it with or without an LVD-capable host adapter. The primary bene- fits of LVD technology include faster transfer rates, increased allowable cable lengths, and improved device connectivity. You can configure the drive to detect between SE and LVD modes automat- ically or force it to operate in SE mode only. To configure this option, see Figure 2. Note. To operate at Ultra2 rates or faster in LVD mode, all devices on the same bus (cable) must be running in LVD mode. If you add any SE device to the bus, all devices on that bus operate in SE mode. Note. Some LVD host adapters provide an LVD connector and an SE con- nector on the same host adapter to allow you to run SE and LVD drives concurrently at their maximum capabilities. Check your SCSI host adapter documentation. See Figure 3. Caution. Do not mix LVD drives on the same bus with high voltage differ- ential (HVD) devices—drive damage may occur. Installation instructions 1. Set the SCSI ID Determine which SCSI IDs are already being used in the system and then assign this disc drive a SCSI ID that isn’t already being used. Use the J6 connector located on the front of the drive to set the SCSI ID (see Figure 1). • Most Cheetah® 10K.6 drives are factory set with the SCSI ID set at 0. If this is the only SCSI drive in your system and there are no other SCSI devices on the daisychain, you can leave this drive’s SCSI ID set to 0 and proceed to the next step. • The host system’s SCSI controller usually uses SCSI ID 7. • If you have an LC model drive, the host normally sets the ID over the I/O interface, so you don’t need to worry about this step. • If you have an LW model drive, some systems provide a cable designed to connect to the J5 jumper block on the drive to remotely set the ID. You can connect this cable to J5 and use the host-provided remote switch to set the SCSI ID. This J5 connector is not present on LC model drives. Figure 1. Setting the SCSI ID (the J5 block is on LW models only) 2. Configure termination If you are installing the drive in a system that has other SCSI devices installed, terminate only the end devices on the SCSI bus (cable). This drive does not have internal terminators or any other way of adding internal termi- nation on the drive. You must provide external termination when termination is required. This is normally done by adding an inline terminator on the end of the cable. See Figure 3 for an illustration showing a system configuration that uses an external terminator. • Use active (ANSI SCSI-2 Alternative 2) single-ended terminators when terminating a bus operating in single-ended mode. • Use SPI-2-compliant active low voltage differential terminators when ter- minating a SCSI Ultra2 bus operating in LVD mode. • The host adapter is normally on the end of the bus and internally termi- nated. You can configure your bus with another device on the end if you remove termination from the host adapter. 3. Configure terminator power (LW model only) Terminators have to get power from some source. The default configuration results in the drive not supplying termination power to the bus. You should normally leave this drive set at this default unless your host system requires the drive to supply termination power to the bus. To configure this drive to supply termination power to the bus, place a jumper on J2 (LW model only) pins 1 and 2 as shown in Figure 2. 4. Connect the drive activity LED (optional) Connect the Drive Activity LED cable to J6 pins 11 and 12 (see Figure 2), or connect a drive ID and Drive Activity LED cable to J5, depending on host system requirements. 5. Check the other available jumper settings Select other options on J2 (LW model only) as illustrated in Figure 2. Do not change these unless instructed to do so by the host system documentation. SCSI ID = 0 (default) Jumper Plug (enlarged to show detail) J6 Drive Front Pin 1 Reserved A2A1A0 A L E D R E S 3 SCSI ID = 1 SCSI ID = 2 SCSI ID = 3 SCSI ID = 4 SCSI ID = 5 SCSI ID = 6 SCSI ID = 7 SCSI ID = 8 SCSI ID = 9 SCSI ID = 10 SCSI ID = 11 SCSI ID = 12 SCSI ID = 13 SCSI ID = 14 SCSI ID = 15 J1 DC Power J1 68 Pin SCSI I/O Connector Drive HDA Rear SCSI ID = 8 SCSI ID = 9 SCSI ID = 10 SCSI ID = 11 SCSI ID = 12 SCSI ID = 13 SCSI ID = 14 SCSI ID = 15 A not used 3 A2 A1 SCSI ID = 0 SCSI ID = 1 SCSI ID = 2 SCSI ID = 3 SCSI ID = 4 SCSI ID = 5 SCSI ID = 6 SCSI ID = 7 A0 J5 Pin 1 4P 3P 2P 1P PCBA Pin 1 +5V Ground (default)

Option select jumpers (LW model only)

6. Mount the drive in the host system and connect cables Note. LC drives are designed to be attached to a carrier or tray and inserted into the host system without I/O or power cables. a. Mount LW model drives to the host system’s chassis using four 6-32 UNC screws. Two mounting holes are in each side of the drive and there are four mounting holes in the bottom of the drive. Do not over- tighten or force the screws. You can mount the drive in any orientation. b. Connect the SCSI I/O cable into the drive’s SCSI connector. Take care not to stretch or crimp this cable, and do not block the system’s cooling air flow with the cable. Note. For Ultra2 and faster operation, special twisted pair LVD cables are required. c. Connect the DC power cable to the drive. See Figure 3. Figure 3. Cable connections and external termination 7. Format the drive The drive has been low level formatted at the factory. You do not need to perform another low level format on this drive unless you decide to perform certain diagnostics through the host adapter. If you do decide to perform a low level format, do not abort the format as this is likely to make the drive inoperable. A low level format, with verify turned on, will typically take two hours. Protect against power failure or other power interruptions during the format. a. Turn on DC power to the host system. b. Boot the system from a system floppy, CD, or from a previously installed hard disc drive if there is one. c. Format the drive. Caution. Formatting a drive erases all user data. Be sure that you under- stand this principle before formatting any hard disc drive. It is not necessary to format a drive that previously has been used to store data, unless your intention is to erase all user data. Seagate® is not responsible for lost user data. Cheetah 10K.6 disc drives are designed to operate with a variety of operat- ing systems. Please refer to your system or SCSI controller manual for infor- mation about formatting and setting up the drive. Some quick desktop system notes are provided below. • MicrosoftTM. Set the drive type in CMOS to “Zero,” “None,” or “No hard drive installed.” Use FDISK.EXE and FORMAT.EXE. Systems using Win- dows 98 or later can create one single partition (drive letter) on the drive. • MacintoshTM. Use a third-party drive utility (most revisions of Apple’s HD Setup utility only work with drives having special Apple firmware). Troubleshooting • Drive does not spin up. Check cables and all jumper settings. Make sure cable pin 1 (edge stripe) matches PCB pin 1. • Drive spins, but no LED on/off activity. Check SCSI ID setting. Set the ID so that each device on the SCSI chain has its own unique ID. See also the next item below. Host I/O controller is usually ID7. • Computer does not seem to recognize the drive. Verify that the drive is enabled by the SCSI host adapter setup utility. • FDISK does not detect the drive. Run the FDISK program located on your Windows startup diskette. Type fdisk/status to verify that your hard drive is present. Seagate support services For online information about Seagate products, visit www.seagate.com or e-mail your disc questions to [email protected]. If you need help installing your drive, consult your dealer first. If you need additional help, call a Seagate technical support specialist. Before calling, note your system configuration and drive model number (ST3146807LW, ST3146807LC, ST373307LW, ST373307LC, ST336607LW or ST336607LC. Africa +31-20-316-7222 New Zealand 0800-443988 Australia 1800-14-7201 Norway 800-113 91 Austria 0 800-20 12 90 Poland 00 800-311 12 38 Belgium 0 800-74 876 Spain 900-98 31 24 Denmark 80 88 12 66 Sweden 0 207 90 073 France 0 800-90 90 52 Switzerland 0 800-83 84 11 Germany 0 800-182 6831 Singapore 800-1101-150 Hong Kong 800-90-0474 Taiwan +886-2-2514-2237 India 1-600-33-1104 Thailand 001-800-11-0032165 Indonesia 001-803-1-003-2165 Turkey 00 800-31 92 91 40 Ireland 1 800-55 21 22 United Kingdom 0 800-783 5177 Italy 800-790695 USA/Canada/ 1-800 SEAGATE or Malaysia 1-800-80-2335 Latin America +1-405-936-1234 Middle East +31-20-316-7222 Other European Netherlands 0 800-732-4283 countries +31-20-316-7222 Warranty. Contact your place of purchase or our web site (above). Return Merchandise Authorization (RMA). Before returning the drive, verify that it is defective. Seagate Worldwide customer service centers are the only facilities autho- rized to service Seagate drives. Contact nearest center for return procedures and trade regulations. Shipping the drive Caution. Back up the data before shipping. Seagate assumes no responsibility for data lost during shipping or service. Shipping drive in an unapproved container voids the warranty. Pack the drive with original box and packing materials. Use no other materials. This prevents electrical and physical damage in transit. © 2002 Seagate Technology LLC All rights reserved Publication number: 100195488, Rev. B, June 2002, Printed in U.S.A. Seagate, Seagate Technology, and the Seagate logo are registered trademarks of Seagate Technology LLC. Cheetah is a registered trademark of Seagate Technology LLC. Other product names are registered trademarks or trademarks of their owners. Seagate reserves the right to change, without notice, product offerings or specifica- tions. Enable parity check of SCSI bus. Disable parity check. J2 Pin 1 Reserved Positions Parity Check option Single-ended I/O Terminator Power Write protect = Off (enables writing). Write protect = On (disables writing). Write Protect option Disable the Delay Motor Start option. Motor start delay equal to the SCSI ID multiplied by 12 seconds. Delay Motor Start option (valid only if the Enable Motor Start jumper is not connected) Enable motor start. The drive waits for the Start Unit command from the host before starting the spindle motor. Disable motor start (default). The drive starts according to the Delay Motor Start option. Motor Start option Pin 1 End SCSI I/O Connector Drive with HDA up, PCB down, viewed from front Pin 1 DC Power Connector J2 Drive Front J6 Pin 1 HDA J6 A2 A3 A1 A0 Reserved Remote LED L E D R E S Reserved Shipped with cover installed. Do not remove. Do not install jumpers on these four positions. J6 Jumper CATH 11 12 J2 Jumper (default) (default) (default) (default) A jumper here forces single-ended I/O operation. No jumper allows host to select either single-ended or LVD operation. Host adapter or other device provides term. power to external terminator. Term. Power to SCSI Bus (default) (default) Pin 1 (check your adapter for Pin 1 location) Host Adapter PCB Twisted Pair LVD Cable Ultra160 or Ultra2 LVD bus segment SPI-2 compliant active LVD external terminator on the end of the cable SCSI LVD/SE SCSI SE Ultra SCSI SE bus segment

Other Storage Manuals