Qlogic QLogic 12000 Series Reference Manual
Text of the manual
QLogic 12000 Series
InfiniBand Switches and Directors
CLI Reference Guide
Version 6.0
QLogic 12000 Series
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no
responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its
use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications
described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no
representation nor warranty that such applications are suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
Document Revision History
Revision E, August 15, 2010
Changes
Sections Affected
Added the following commands to the group
Network:
dnsParamsShow
dnsParamsSet
“Network” on page 1-39
Table of Contents
Preface
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v
Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v
License Agreements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
Knowledge Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
1
Switch Command Line Interface
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1
Commands and Functional Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2
Online Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4
Keyboard Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4
Accessing the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4
Groups and Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-32
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-39
Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-52
Subnet Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-59
Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-91
Key Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-98
IbSwitchInfo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-100
TimeManagement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-122
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-126
CaptureInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-132
This manual describes the command line interface (CLI) task information for the
QLogic 12300 and 12800 family of switches.
This manual is organized as follows:
This section describes the intended audience and technical support.
Section 1 describes the 12000 switch CLI commands.
Intended Audience
This manual is intended to provide network administrators and other qualified
personnel a reference for the command line interface of the QLogic 12000 series
switches.
Documentation Conventions
This guide uses the following documentation conventions:
NOTE: provides additional information.
CAUTION! indicates the presence of a hazard that has the potential of
causing damage to data or equipment.
WARNING!! indicates the presence of a hazard that has the potential of
causing personal injury.
Text in blue font indicates a hyperlink (jump) to a figure, table, or section in
this guide, and links to Web sites are shown in underlined blue. For
example:
Table 9-2 lists problems related to the user interface and remote agent.
See “Installation Checklist” on page 3-6.
For more information, visit www.qlogic.com.
Text in bold font indicates user interface elements such as a menu items,
buttons, check boxes, or column headings. For example:
Click the Start button, point to Programs, point to Accessories, and
then click Command Prompt.
Under Notification Options, select the Warning Alarms check box.
Text in Courier font indicates a file name, directory path, or command line
text. For example:
To return to the root directory from anywhere in the file structure:
Type cd /root and press ENTER.
Enter the following command: sh ./install.bin
Key names and key strokes are indicated with UPPERCASE:
Press CTRL+P.
Press the UP ARROW key.
Text in italics indicates terms, emphasis, variables, or document titles. For
example:
For a complete listing of license agreements, refer to the QLogic
Software End User License Agreement.
What are shortcut keys?
To enter the date type mm/dd/yyyy (where mm is the month, dd is the
day, and yyyy is the year).
Topic titles between quotation marks identify related topics either within this
manual or in the online help, which is also referred to as the help system
throughout this document.
License Agreements
Refer to the QLogic Software End User License Agreement for a complete listing
of all license agreements affecting this product.
Technical Support
Customers should contact their authorized maintenance provider for technical
support of their QLogic products. QLogic-direct customers may contact QLogic
Technical Support; others will be redirected to their authorized maintenance
provider.
Visit the QLogic support Web site listed in Contact Information for the latest
firmware and software updates.
Availability
QLogic Technical Support for products under warranty is available during local
standard working hours excluding QLogic Observed Holidays.
QLogic offers training for technical professionals for all iSCSI, InfiniBand, and
Fibre Channel products. From the main QLogic web page at www.qlogic.com,
click the Education and Resources tab at the top, then click the Education &
Training tab on the left. The QLogic Global Training Portal offers online courses,
certification exams, and scheduling of in-person training.
Technical Certification courses include installation, maintenance and
troubleshooting QLogic products. Upon demonstrating knowledge using live
equipment, QLogic awards a certificate identifying the student as a Certified
Professional. The training professionals at QLogic may be reached by e-mail at
[email protected].
Contact Information
Please feel free to contact your QLogic approved reseller or QLogic Technical
Support at any phase of integration for assistance. QLogic Technical Support can
be reached by the following methods:
Knowledge Database
The QLogic knowledge database is an extensive collection of QLogic product
information that you can search for specific solutions. We are constantly adding to
the collection of information in our database to provide answers to your most
urgent questions. Access the database from the QLogic Support Center:
http://support.qlogic.com.
Web
http://support.qlogic.com
Email
[email protected]
Switch Command Line
Interface
Overview
This section details the usage of the Command Line Interface (CLI) feature for the
QLogic 12000 family of switches:
The QLogic 12300
The QLogic 12800 Series:
12800-040
12800-120
12800-180
12800-360
The CLI allows the user to perform remote configuration and management tasks,
which in many respects mirrors the functionality of the Chassis Viewer GUI.
The CLI is accessed via a terminal attached to the RS232 port(s) or via the OOB
management port using Telnet and secure shell (SSH) of:
The 12300 chassis
The SEEB module(s) of the 12800 series
Accessing the CLI through the serial port does not require a login and password
(unless configured to do so) and defaults to administrator privileges. Providing
access through the serial port means that users will always have access to the
switch, even if Telnet and SSH are not functioning.
For a standalone switch, the user would Telnet to the IP address(es) of the unit.
Once connected, the CLI works as any telnet session does.
To access the CLI using Telnet and SSH, a login and password is required. There
are two user modes, operator and administrator with the following access
privileges:
Operator:
Read only access.
Switch Command Line Interface
Commands and Functional Groups
1-2
D000103-000 E
Administrator:
Read and write Access.
Reboot access.
Can change operator and administrator passwords.
Can disable user login and passwords. This would allow all users
admin-level access without the need for a user name or password.
Can view all current user sessions
Can access all of the commands executed from any open operator
session.
Can log out any open user sessions
Can send messages to the open user sessions
The CLI allows multiple users to be logged in simultaneously. However, some
commands will be locked to a user(s) if another user is executing the same
command.
Commands and Functional Groups
The list of available commands can be accessed by typing list. To keep the list
short, the commands are grouped into functional groups, which are:
General:
General commands for user management and CLI configuration.
Deprecated:
Commands that have been deprecated.
The Deprecated group contains CLI commands that have been replaced or
are to be removed. Please use the new command where appropriate.
Chassis:
Chassis management commands. (FRU info, fan/power supply state, etc).
Network:
Ethernet interface management commands.
Firmware:
Provides commands for updating the firmware via a File Transfer Protocol
(FTP) server or Secure Copy Protocol (SCP) (if using SSH to access the
Bridge Module). The switch has the ability to store the location of the firmware
files for future upgrades. Additionally, the Firmware functional group includes
commands for viewing the current firmware revisions and for changing the
boot image.
Switch Command Line Interface
Commands and Functional Groups
D000103-000 E
1-3
SubnetManagement:
InfiniBand subnet manager configuration and management.
Log:
Provides commands for viewing log files as well as configuring logging
parameters.
KeyManagement:
License key management.
IbSwitchInfo:
Provides commands for displaying InfiniBand (IB) statistics for all IB ports on
the switch, as well as for configuring port statistic thresholds.
TimeManagement:
Provides commands for retrieving and setting the current system time, as well
as commands for setting the time zone and daylight saving time parameters.
Snmp:
Provides commands for configuring SNMP trap destinations and security
parameters required to access the switch from an SNMP manager.
CaptureInfo:
Provides commands for capturing switch-specific information for the purposes
of analysis and debugging.
To list commands within a functional group, simply type in the functional group name.
For example, to list all of the firmware commands, type list Firmware. The system
displays information similar to the following:
-> list Firmware
fwUpdateSlot Update units firmware
fwUpdateChassis Update units firmware
fwListFiles List the contents of the firmware ramdisk
fwShowUpdateParams Display firmware default update parameters
fwSetUpdateParams Configure firmware default update parameters
showCapability Display the capabilities/features
showLastScpRetCode Display the return code from the last SCP Firmware Push
fwVersion Display Firmware revisions
bootQuery Query boot image information
bootSelect Change boot selection
Switch Command Line Interface
Online Help
1-4
D000103-000 E
Online Help
The online help for the CLI provides, for each command, all necessary information
to successfully execute the command. For example, typing help list (can also type
list help) displays the following information for the list command:
NAME
list
SYNOPSIS
list [group] [-noprompt] [-verbose]
DESCRIPTION
List available commands.
OPTIONS
group - List the commands in that particular group
-noprompt - Just list the command groups.
-verbose - Print full help for each command, instead of summary.
NOTES
Specify the group name or use 'all' to list all available commands.
Keyboard Shortcuts
The CLI keeps a history of recently executed commands. This history is
available via the Up and Down arrow keys.
Users may edit the current command with the Left and Right arrow keys.
Tab completion: pressing the Tab key after typing at least one character
either completes a command or lists all the available commands that begin
with the characters already typed.
Accessing the CLI
NOTE:
The CLI can be accessed via Telnet, SSH, or through the switch RS232
serial port. The following instructions use Telnet.
1. Telnet to the IP address of the switch (the default IP address is 192.168.100.9)
with the following command:
telnet
2. The system prompts for a username. The CLI has the following default user
names:
Operator access: operator
Administrator access: admin
Type the appropriate username and press Enter.
Switch Command Line Interface
Keyboard Shortcuts
D000103-000 E
1-5
3. The system prompts for a password. The CLI has the following default
passwords:
Operator access: operpass
Administrator access: adminpass
Type the appropriate password and press Enter. The system responds with:
Welcome to the CLI. Type 'list' for the list of
commands.
Switch Command Line Interface
Groups and Commands
1-6
D000103-000 E
Groups and Commands
The following section lists all CLI functional groups along with the commands for
each group. Commands for all 12000 switches are listed. Any commands specific
to a switch(es) is noted. For more specific information for each functional group,
the user would execute the help command. For more specific
command information, the user would execute the help
command.
General
help
Displays help information for a specific command.
Syntax:
Options:
Sample Output:
NOTES: General Help
Type list or ? for the list of commands.
To get help on a particular command type: commandname help.
For convienence purposes you can also type: help commandname
help [command]
[command]
The command to display help for.
-> help list
NAME
list
SYNOPSIS
list [group] [-noprompt]
DESCRIPTION
List available commands.
OPTIONS
group - List the commands in that particular group
-noprompt - Just list the command groups.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-7
Use the Up and Down arrow keys to browse command history, Left and Right arrow
keys to edit the current command and the Tab key for tab completion of a command.
Two alternate key bindings exist for the backspace and delete keys. If these keys
are not responding as expected use the swapBsDel command to swap the
bindings.
Commands are grouped into subcategories. To list the commands in a subcategory
type in the category heading. Category headings are identified by starting with a
capital letter. For example, to list all the commands that handle log configuration
type Log.
In each help description, items in brackets(e.g. [] in this help
description) represent optional parameters. User selectable input is indicated by
items within the '<' and '>' symbols(e.g. ). Text outside the '<' and '>'
characters is the actual text that needs to be entered. When there is more than one
choice, the options are specified within '{' and '}' characters, where the options are
separated by '|' characters.
list
Displays a list of all valid commands.
Syntax:
Options:
Sample Output:
list [all] [group] [-noprompt] [-verbose]
all
List the commands for all groups.
group
Displays a list of commands for a particular group
-noprompt
Displays a list of the command groups only.
-verbose
Print full help for each command, instead of summary.
list
List of Valid Commands:
General General commands for user management and CLI configuration.
Deprecated These commands have been deprecated
Network Snmp configuration commands.
Firmware Update firmware and display current revision levels.
Log Log file display and configuration
IbSwitchInfo InfiniBand port configuration and statistics
TimeManagement Display and configure the system time
Snmp Snmp configuration commands.
Type the name of the group you want to list or return to exit:
Switch Command Line Interface
Groups and Commands
1-8
D000103-000 E
NOTES:
Use 'list all' to display brief help for all available commands.
Use 'list all -verbose' to display verbose help for all commands.
Use 'list -noprompt' to display the list of command groups.
history
Displays the command history for this session.
Syntax:
Options:
Sample Output:
reboot (12300)
Reboots the device.
Syntax:
history
None.
-> history
command history [30 max lines]:
list
Deprecated
Network
Firmware
Log
IbSwitchInfo
TimeManagement
Snmp
Ethernet
help
list
history
reboot [now][-m][slot n][-s][-n][all]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-9
Options:
Sample Output:
NOTES: You may reboot the local (Master) Managment Module or the remote
(Slave) Managment Module with one or multiple arguments.
Non-disruptive arguments will not interfere with switch traffic.
Providing the argument all performs disruptive reboot of all present Managment
Modules and cards.
If rebooting the local device from telnet, ssh, etc., you will have to reconnect after
rebooting.
Default (no arguments) reboots local device disruptively after prompt.
See also: 'resetCard', 'showInventory'.
reboot (12800 Series)
Reboots the device.
Syntax:
now
Does not prompt the user before rebooting.
-m
Reboot Master (local) QLogic 12300 (non-disruptive).
slot n
reset specific device where n = slotNumber (disruptive).
-s
Reboot Slave (remote) QLogic 12300
-n
Reboot Slave (remote) management card only (non-disruptive)
all
Reboot All local devices (excludes -n/-m/-s).
-> reboot
Disruptive reboot selected
Proceed with reboot? [N]
reboot [now][-m][slot n][-s][-n][all]
Switch Command Line Interface
Groups and Commands
1-10
D000103-000 E
Options:
Sample Output:
NOTES: You may reboot the local (Master) Managment Module or the remote
(Slave) Managment Module with one or multiple arguments.
Non-disruptive arguments will not interfere with switch traffic.
Providing the argument all performs disruptive reboot of all present Managment
Modules and cards.
If rebooting the local device from telnet, ssh, etc., you will have to reconnect after
rebooting.
Default (no arguments) reboots local device disruptively after prompt.
See also: 'resetCard', 'showInventory'.
killCliSession
Terminates an existing CLI session
Syntax:
Options:
now
Does not prompt the user before rebooting.
-m
Reboot Master (local) Management Module 228 (non-disruptive).
slot n
reset specific device where n = slotNumber (disruptive).
-s
Reboot Slave (remote) Management Module 227.
-n
Reboot Slave (remote) management card only (non-disruptive)
all
Reboot All local devices (excludes -n/-m/-s).
-> reboot
Disruptive reboot selected
Proceed with reboot? [N]
killCliSession sessionNumber
sessionNumber
The sessionNumber that is returned from the who command.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-11
Sample Output:
NOTES: This command logs out remote sessions. Use 'who' to obtain the list of
active sessions.
who
Displays currently active CLI sessions.
Syntax:
Options:
Sample Output:
NOTES: Displays a list of currently active CLI sessions. Note that a session can
be 'active', but no user information available (in most cases, this indicates the
session is waiting for the user to enter login information).
For each session the following information is displayed:
user: username of the logged in user
role: security role of the user
index: internal session index
logged in: timestamp of when the user logged in
last cmd: timestamp of the users last command
type: method used to connect to the system
ip address: ip address of the user (if applicable)
broadcast
Write a message to all active CLI sessions
Syntax:
-> killCliSession
must supply session number
who
None.
user role index logged in last cmd type ip address
---------------------------------------------------------------------------------------------------
admin admin 0 13:19:03 07/11/2008 09:41:20 07/11/2008 serial 0.0.0.0
broadcast msg
Switch Command Line Interface
Groups and Commands
1-12
D000103-000 E
Options:
Sample Output:
NOTES: Writes the supplied message to all other active CLI sessions. The message
to be written must be encapsulated in quotes, and non-empty.
swapBsDel
Swaps the backspace and delete character key bindings.
Syntax:
Options:
Sample Output:
NOTES: Terminals may bind the backspace and delete key bindings differently.
This command swaps two commonly used bindings, which allow the user to use
the backspace and delete keys properly without having to adjust their terminal
settings. Backspace and delete swapping is persistently maintained per user (i.e.
each login account can have a separate binding).
setTermWidth
Change the terminal width for text formatting purposes.
Syntax:
Options:
msg
Message (Note: the message text must be encapsulated in quotes "".
-> broadcast "The system will be rebooted in 5 minutes."
swapBsDel
None.
-> swapBsDel
setTermWidth width
width
Width of the user’s terminal window. Minimum width is 20 characters.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-13
Sample Output:
NOTES: Allows modification of the terminal width used for text formatting purposes.
Note that not all commands adhere to this setting. The minimum width is 20
characters.
getTermWidth
Displays the terminal width for text formatting purposes.
Syntax:
Options:
Sample Output:
NOTES: Displays the terminal width used for text formatting purposes. Note that
not all commands adhere to this setting.
prompt
Set the CLI prompt (global for all active CLI sessions).
Syntax:
Options:
Sample Output:
NOTES: This changes the prompt for all CLI sessions. The prompt may not exceed
11 characters and is not saved across reboots. If the prompt contains a space,
asterick, comma, parenthesis or semicolon it must be enclosed with double quotes
-> setTermWidth 100
getTermWidth
None.
-> getTermWidth
Current terminal width: 80 characters.
prompt str
str
The new prompt.
prompt -> "12300->"
12300->
Switch Command Line Interface
Groups and Commands
1-14
D000103-000 E
". For example: "*a prompt*". Also, if a prompt is not accepted try to enclose it with
double quotes. In order for some FastFabric Tools to function correctly, the prompt
must end in "-> " (note trailing space).
case
Display or change the case sensitivity for the command interpreter for the CLI session.
Syntax:
Options:
Sample Output:
NOTES: This displays or changes the case sensitivity for the command interpreter
for the CLI session. If an option is not specified the current case sensitivity is
displayed, otherwise the case sensitivity is turned on or off depending on the
specified option. When case sensitivity is on, the CLI input must match the exact
character case (lower and upper case) as specified in the help text. When case
sensitivity is turned off, the input may be any combination of upper and lower case.
showLastRetCode
Display the return code from the last executed command.
Syntax:
Options:
Sample Output:
NOTES: This allows for automated systems to determine if a command was
successful or not.
case [off | on]
off | on
Turn case sensitivity off or on.
-> case off
Case sensitivity is now off
showLastRetCode [-brief]
-brief
Displays just the numeric value of the return code.
-> showLastRetCode
Last Exit Code: 0: Success
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-15
echo
Echoes text back to the output..
Syntax:
Options:
Sample Output:
NOTES: This echoes the text for each argument back to the output. If there are
multiple arguments they are separated by spaces.
rlogin
Creates I/O terminal to local cards.
Syntax:
Options:
Sample Output:
NOTES: This command allows users to open a terminal to local I/O devices within
the chassis. The command rcmd is an alias of rlogin. See also hostShow.
echo [ ...]
[ ...]
Text to be echoed..
-> echo test
test
rlogin [hostName]
hostName
The name of the device to connect.
-> rlogin Slave
Switch Command Line Interface
Groups and Commands
1-16
D000103-000 E
rcmd
Creates I/O terminal to local cards.
Syntax:
Options:
Sample Output:
NOTES: This command allows users to open a terminal to local I/O devices within
the chassis. The command rcmd is an alias of rlogin. See also hostShow.
resetCard
Reboot a specific slot in the chassis.
Syntax:
Options:
Sample Output:
NOTES: If you reset the switch you are connected to you will have to reconnect.
You can find out the valid slots for this device with the 'showInventory' command.
rcmd [hostName]
hostName
The name of the device to connect.
-> rcmd Slave
resetCard n [now]
n
Chassis slot number.
now
No prompt before resetting the card.
-> resetCard 101 now
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-17
logout
Logout of the current CLI session.
Syntax:
Options:
Sample Output:
user
Change user accounts.
Syntax:
Options:
Sample Output:
NOTES: Use this command to change to the 'operator' account, or to the 'admin'
account. The minimum password length is 8 characters. The maximum length is 40
characters.
logout
None.
logout
user [user]
[user]
Name of user account to change to.
-> user operator
User changed to: operator
Switch Command Line Interface
Groups and Commands
1-18
D000103-000 E
passwd
Change users password(s).
Syntax:
Options:
Sample Output:
NOTES: Allows the modification of the user's password.
userAdd
Add a user account.
Syntax:
Options:
Sample Output:
passwd [username]
[username]
Name of the user whose password needs to be changed.
-> passwd operator1
User password changed successfully
userAdd [role] [username] [password]
[role]
Can be either admin or operator.
[username]
The name of the user to be added.
[password]
Optional password. If not supplied the default password for that role is used.
-> userAdd admin Bob
User added: Bob
Password is set to the default password for this role: admin
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-19
userRem
Remove a user account.
Syntax:
Options:
Sample Output:
userListShow
List all user accounts for this device.
Syntax:
Options:
Sample Output:
userRem [username]
username
Name of the user to be removed.
-> userRem Bob
User deleted: Bob
userListShow
None.
-> userListShow
username role
operator1 operator
USERID admin
Bob admin
Switch Command Line Interface
Groups and Commands
1-20
D000103-000 E
sshKey
Adds, displays, and removes SSH public keys for individual users..
Syntax:
Options:
Sample Output:
NOTES: Adds, displays, and removes SSH public keys for individual users. Users
with administrative privileges may use the -u option to manage keys for other users.
sshKey [-u ] []
show
Displays the SSH public keys in the users authorized_keys file.
add “”
Add key to the users authorized_keys file. Must be enclosed within double-quotes
("").
rem
Remove key at for the user.
rem -all
Remove all keys for the usern.
-u
Perform the operation on the user (for admins only).
-> sshKey show
Index Key
-----------------------------------
1 "ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAQEArNiSexu30rZjs1HAXbDBwTgJgcxLF..."
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-21
loginMode
Allows the user to change the user interface authentication requirements.
Syntax:
Options:
Sample Output:
NOTES: This command displays or changes how users are authenticated when
connecting to the GUI or CLI. With no parameters, the current login mode is
displayed. The login mode can be changed by specifying a single integer parameter
indicating which of the following modes should become active:
0 - Username and password required
1 - Password is not required
2 - Username / password are not required
3 - LDAP Authentication
When usernames are disabled, all users will be logged on as the administrative
user. There is no way to change this behavior.
setldapSvrIpAddr
Modify the LDAP Server IP Address.
Syntax:
Options:
Sample Output:
loginMode [mode]
[mode]
Determines how users are able to login.
-> loginMode 1
Mode successfully changed to: 1 = Password is not required
setldapSvrIpAddr [ipaddress]
[ipaddress]
The IP address of the ldap server you wish to set to authenticate in the format
"192.168.0.1"
-> setldapSvrIpAddr 192.168.0.29
Switch Command Line Interface
Groups and Commands
1-22
D000103-000 E
NOTES: This sets the LDAP server ip address. The LDAP server will be contacted
for remote authentication.
setldapSvrPort
Modify the LDAP Server Port.
Syntax:
Options:
Sample Output:
NOTES: Sets the LDAP server port. The LDAP server will be contacted for remote
authentication.
idleTimeoutGet
Retrieves the UI idle timeout value.
Syntax:
Options:
Sample Output:
NOTES: Displays the system idle timeouts for the GUI and CLI interfaces. If set to
zero, the timeout is disabled.
setldapSvrPort [port]
[port]
The port of the LDAP server to be authenticated.
-> setldapSvrPort 389
idleTimeoutGet [--all] [--cli] [--gui]
--all
Display all timeouts. This is the default if no options are specified.
--cli
Display the timeout for CLI sessions.
--gui
Display the timeout for GUI sessions.
-> idleTimeoutGet
Timeout is 600 seconds.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-23
idleTimeoutSet
Set the UI idle timeout value.
Syntax:
Options:
Sample Output:
NOTES: Modifies the idle timeout for the CLI or GUI interfaces. Timeouts are in
number of seconds, with zero meaning the timeout is disabled.
sessionTimeoutDisable
Disable the idle timeout for the current CLI session.
Syntax:
Options:
Sample Output:
NOTES: Disables the idle timeout for the current CLI session. This value does not
persist across instances of the session (i.e., each time you log on, it will default back
to the system default value).
idleTimeoutSet [--all | --cli | --gui] seconds]
[seconds]
Idle timeout value (in seconds).
--all
Set the idle timeout for both the CLI and the GUI to the same value.
--cli
Set the idle timeout for the CLI. This is the default if no identifier is specified.
--gui
Set the idle timeout for the GUI.
-> idleTimeoutSet --all 700
Timeout is set to 700 seconds.
sessionTimeoutDisable
None.
-> sessionTimeoutDisable
Disabled session idle timeout.
Switch Command Line Interface
Groups and Commands
1-24
D000103-000 E
sessionTimeoutEnable
Enable the idle timeout for the CLI session.
Syntax:
Options:
Sample Output:
NOTES: Enables the idle timeout for the current CLI session. This value does not
persist across instances of the session (i.e., with each log on, it defaults back to the
system default value).
loginMsgGet
Displays the CLI login message for this device.
Syntax:
Options:
Sample Output:
NOTES: Displays the current login welcome message for the CLI. This message
can be customized with the loginMsgSet command.
loginMsgSet
Set the CLI login message for this device.
Syntax:
sessionTimeoutEnable
None.
-> sessionTimeoutEnable
Enabled session idle timeout.
loginMsgGet
None.
-> loginMsgGet
Welcome message: Be certain to logout when you are finished using the
CLI.
loginMsgSet [message] [-clear]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-25
Options:
Sample Output:
NOTES: This command can be used to modify the welcome message displayed
when logging onto the CLI. The current message can be viewed with the
loginMsgGet command.
loginNameGet
Display the name of the device displayed when logged into via telnet.
Syntax:
Options:
Sample Output:
NOTE: The login name is an arbitrary string displayed prior to a user attempting a
login to a new CLI session. This command displays the current value of this string.
loginNameSet
Modify the string displayed to users prior to attempting a login for a new CLI session.
Syntax:
[message]
The login message (should be encapsulated in quotes “ “).
[-clear]
Clear welcome message.
-> loginMsgSet "Be certain to logout when you are finished using the
CLI."
Welcome message set successfully
loginNameGet
None.
-> loginNameGet
login-name: Switch1
loginNameSet [option]
Switch Command Line Interface
Groups and Commands
1-26
D000103-000 E
Options:
Sample Output:
NOTES: The login name is an arbitrary string displayed prior to a user attempting
a login to a new CLI session. This command modifies this string. The current name
can be viewed with the loginNameGet command.
serialAuthGet
Displays the current serial authentication status.
Syntax:
Options:
Sample Output:
NOTES: Displays whether user login and authentication is required on the serial
console of the system.
serialAuthSet
Enable or disable authentication on the systems serial console.
Syntax:
Options:
[name]
Set the login name.
[-clear]
Clear the login name.
-> loginNameSet Switch1
login-name set successfully
serialAuthGet
None.
-> serialAuthGet
Serial authentication is currently disabled.
serialAuthSet [enable]
[enable]
Boolean value to enable or disable serial authentication.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-27
Sample Output:
NOTES: This command is used to enable or disable user authentication on the
serial console. Use 1 as the only parameter to enable authentication, or 0 to disable
authentication. Exit and re-login for the setting to take effect. The login mode must
be set to 0 or 1 for authentication to take place on the serial port.
uiConfig
View or configure the user interfaces to this device.
Syntax:
Options:
Sample Output:
NOTES: There are several access methods for this device. With no arguments,
this command displays which access methods are available, and whether each
method is enabled or disabled.
-> serialAuthSet 1
Serial authentication set to enabled.
uiConfig [-telnet 0|1] [-https 0|1] [-http 0|1] [-ftp
0|1] [-snmp 0|1]
[telnet]
Enable/disable access to the device via telnet..
[https]
Enable or disable https access.
[http]
Enable or disable http access.
[ftp]
Enable or disable ftp access.
[snmp]
Enable or disable SNMP access.
-> uiconfig -telnet 0
Successfully modified configuration.
Option Value
-----------------------
telnet 0
http 1
https 0
ftp 1
snmp 1
Switch Command Line Interface
Groups and Commands
1-28
D000103-000 E
This command can also be used to enable or disable various access methods. Use
'- 0' to disable a protocol, and '- 1' to enable. Multiple operations
may be specified in a single command.
A reboot is not required for this command. Depending on the specific method, it
may take 5-10 seconds for the changes. Note that existing connections (for example
a telnet session) will not be affected by disabling the underlying access method.
Any access method supported by the device (but not listed here) cannot be
configured and is always enabled.
genPost
Displays General POST results and runs tests
Syntax:
Options:
Sample Output:
NOTES: Displays General POST results and runs tests.
genPost
None.
MasterMM202-> genpost
ID Gen POST Name Result ENA DEM PWR Result-Ext
---------------------------------------------------------------------------
* POST TEST CPU NO-RUN Y N Y
* POST TEST MEM DRAM NO-RUN Y N Y
* POST TEST BOOTROM IMG CHKSUM NO-RUN Y N Y
* POST TEST RUN-TIME IMG CHKSUM NO-RUN Y N Y
* POST TEST JMP RAM NO-RUN Y N Y
6 POST TEST I2C PROBE NO-RUN Y Y N
7 POST TEST FAN TRAYS NO-RUN Y Y N
8 POST TEST PWR SUPPLIES NO-RUN Y Y N
9 POST TEST REAL-TIME CLOCK NO-RUN Y Y N
10 POST TEST PROTO NO-RUN Y Y N
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-29
IpoIbConfigShow
Displays the IPoIB Enable/Disable setting.
Syntax:
Options:
Sample Output:
IpoIbConfigEnable
Enable IPoIB feature.
Syntax:
Options:
Sample Output:
IpoIbConfigDisable
Disables the IPoIB feature.
Syntax:
Options:
Sample Output:
IpoIbConfigShow
None.
-> IpoIbConfigShow
IpoIbConfigEnable <- IpoIb enable>
None.
-> IpoIbConfigEnable
IpoIbConfigDisable
None.
-> IpoIbConfigDisable
Switch Command Line Interface
Groups and Commands
1-30
D000103-000 E
IpoIbAddressShow
Displays the IpoIb IP address and associated netmask.
Syntax:
Options:
Sample Output:
NOTES: IPoIB must be enabled to display these fields.
IpoIbAddressSet
Change the IpoIb IP address and associated network mask.
Syntax:
Options:
Sample Output:
NOTES: IPoIB must be enabled to display these fields.
IpoIbAddressSetIPv6
Changes the IPoIB IPv6 address and netmask.
Syntax:
IpoIbAddressShow
None.
-> IpoIbAddressShow
IpoIbAddressSet -h ipaddress -m netMask
[-h ipaddress]
the new IP address in dotted notation format 'xxx.xxx.xxx.xxx'.
[-m netMask]
network mask. (in hexidecimal format).
-> IpoIbAddressSet -h 123.45.6.789
IpoIbAddressSetIPv6
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-31
Options:
Sample Output:
NOTES: The is made up of two major
components, separated by a '/'. The ipv6Address is in notation format
'a:b:c:d:e:f:g:h', where embedded 0s can be shortened (for example, 'a:b::g:h'). The
netMaskLen is a value between 0 and 128 inclusive.
IpoIbAddressShowIPv6
Displays the IPoIB IPv6 Address and associated netmask settings.
Syntax:
Options:
Sample Output:
exit
Exit the CLI.
Syntax:
Options:
Sample Output:
See NOTES.
-> IpoIbAddressSetIPv6
IpoIbAddressShowIPv6
None.
-> IpoIbAddressShowIPv6
exit
None.
exit
Switch Command Line Interface
Groups and Commands
1-32
D000103-000 E
Chassis
hwCheck
Runs a system check at the chassis level and returns current hardware status.
Syntax:
Options:
Sample Output:
NOTES: Returns OK or provides detailed status/warning/error information. If an
error/warning is detected, this command automatically provides verbose
information.
hwMonitor
Displays current port states, fan speeds, temperatures, and voltages.
Syntax:
Options:
hwCheck
[n - 0=default, 1=verbose]
-> hwCheck
Chassis hardware status: GOOD
hwMonitor [slot] [onepass]
[slot]
Slot number to display. 0 for current slot of the management board.
[onepass]
Display the current values and exits. Do not continuosly monitor.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-33
Sample Output:
NOTES: To exit monitoring, press the enter key.
The slot number may require a prefix. The prefix for a Leaf is 'L', the prefix for a
Spine is 'S', the prefix for a Mangement Module is 'M', the prefix for a Power Supply
is 'P', the prefix for a Fan is 'F', and the prefix for the Chassis is 'C'. The Leaf, Spine
and Management Module slots do not require a prefix. The Power Supply, Fan and
Chassis slots require a prefix since their slot numbers overlap with the Leaf, Spine
and Management Module slot numbers.
showIBNodeDesc
Displays the IB Node subnet management agent (SMA) Description..
Syntax:
(Sample 1)
-> hwMonitor 0
System monitor, Uptime: 0 days 4 hours 55 minutes 37 seconds
MODULES MODULES(cont) MODULES(cont) Power & Fans
SLOT|P|TMP|VLT SLOT|P|TMP|VLT SLOT|P|TMP|VLT SLOT|P|SPEED SLOT|P|SPEED
| |E|W|E|W | |E|W|E|W | |E|W|E|W | | | |
M201 |*| | | | L101 |*| | | | | | | | | P201| | F201|*| 6840
M202 |*| | | | L102 |*| | | | | | | | | P202|*| F202|*| 6480
S105A|*| | | | L103 |*| | | | | | | | | P203| | F203|*| 6480
S105B|*| | | | L104 |*| | | | | | | | | P204|*| F204|*| 6840
Max Temp=60C (Management Module 202)
Legend: P=pres/abs TMP=Temperature VLT=Voltage E=Err W=Warn (X=Err/Warn found)
(Sample 2)
-> hwMonitor 0
System monitor, Uptime: 0 days 4 hours 57 minutes 2 seconds
DETAIL FOR DEVICE:
Leaf 101
Temperatures: Base Board: [fusion]=31C [asic]=40C
Voltages: Base Board
[FPGA_1.5V_AUX]=1.555 [PCIE_1.5V_BULK]=1.480 [3.3V_AUX]=3.312
[VDD_1.0V_BULK]=0.980 [AVTR_1.2V_BULK]=1.161 [AVDD_1.5V_BULK]=1.474
[3.3V_BULK]=3.290 [AVTT_1.5_BULK]=1.485 [PLL_2.5_BULK]=2.391
InfiniBand Port Status
L101P01[ Down ] L101P02[ Down ] L101P03[ Down ]
L101P04[ Down ] L101P05[ Down ] L101P06[ Down ]
L101P07[ Down ] L101P08[ Down ] L101P09[ Down ]
L101P10[ Down ] L101P11[ Down ] L101P12[ Down ]
L101P13[ Down ] L101P14[ Down ] L101P15[ Down ]
L101P16[ Down ] L101P17[ Down ] L101P18[Active]
L101P19S105BP18[Active] L101P20S105BP17[Active] L101P21S105AP21[Active]
L101P22S105BP15[Active] L101P23S105AP23[Active] L101P24S105AP24[Active]
L101P25S105AP25[Active] L101P26S105AP26[Active] L101P27S105AP27[Active]
L101P28S105AP28[Active] L101P29S105AP29[Active] L101P30S105AP30[Active]
L101P31S105BP06[Active] L101P32S105BP05[Active] L101P33S105BP04[Active]
L101P34S105BP03[Active] L101P35S105BP02[Active] L101P36S105BP01[Active]
showIBNodeDesc [-d]
Switch Command Line Interface
Groups and Commands
1-34
D000103-000 E
Options:
Sample Output:
NOTES: Entering this command with no parameters displays the current Node
Description. The -d option will display the unit's default value.
setIBNodeDesc
Changes the IB Node (SMA) Description.
Syntax:
Options:
Sample Output:
NOTES: New node name must be enclosed in quotes. Node name must be less
than 64 characters.
setIBNodeDescFormat
Changes the IB Node (SMA) description format modifier.
Syntax:
Options:
[-d]
Show the default Node Name for this unit.
-> showIBNodeDesc
IB Node (SMA) Description is = QLogic 12300 GUID=0x00066a00030001xa
setIBNodeDesc "New Node String"
None.
-> setIBNodeDesc "QLogic 12300 GUID=0x00066a00da000"
IB Node (SMA) Description successfully changed to = QLogic 12300
setIBNodeDescFormat [format]
[format]
Use 0 or 1 to set the format
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-35
Sample Output:
NOTES: If the format is not specified, then the current format selection value is
displayed. When the format is 0, the SMA node description is in a verbose format.
When the format is one the format is brief. The brief format is more consistent with
the CLI/GUI Port Stat port naming.
fruInfo
Displays the EEProm contents.
Syntax:
Options:
Sample Output:
NOTES: The '-all' parameter performs this command against all available slots for
the device.
-> setIBNodeDescFormat
Format = 0
fruInfo [slot|'-all']
[slot]
Slot that you wish to display EEProm contents. Defaults to 0 (chassis EEProm)
-> fruInfo
xInfo_ChassisInfo:
RecType: 1 LastRec: 0 LenMult: 0
ReadOnly: 1 RecordFormat: 2 RecLen: 14
LogicalLen: 020
HdrChkSum: c6
ChassisGuid: 00066a000300012a
SlotCount: 1 (IB Mods in Chassis)
SlotNumbers: 81 (pairs:ext0|Slt1)
CmeAccess: 80 (bits:ext0|Slt1|Cme)
SlotNumber: 0 <-Record accessed via this slot
CmeAccessBits: 2 (Access slot relative)
ProxyAccess: 0 (Access slot relative)
LockDrivesCTR: 0 (Clear to Remove interlock)
MechLock: 1
NodeCount: 0
...
Switch Command Line Interface
Groups and Commands
1-36
D000103-000 E
chassisQuery
Displays information about modules inserted in the chassis that support firmware updates. This
includes information regarding cardType, Board Support Package (BSP) and SlotNumber.
Syntax:
Options:
Sample Output:
NOTES: Entering this command with no parameters will display all currently
occupied card slots.
showInventory
Displays a detailed list of all hardware within the chassis.
Syntax:
Options:
chassisQuery [-master] [-slave] [slot] [-showType]
[-type card_type] [-ignoreInvalidType]
[-master]
Display the master slot number
[-slave]
Display slave slot number
[n]
slot number (numeric)
[-showType]
display the card type
[-type card_type]
display slots that have given card type
[-ignoreInvalidType]
do not return an error if an invalid card type is supplied
MasterMM202-> chassisQuery
slots: 201 202
showInventory
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-37
Sample Output:
setBeacon
Allows the user to view/set the chassis beacon.
Syntax:
Options:
Sample Output:
NOTES: Calling this function with no argument displays its current value.
setSystemContact
Allows the user to set/show the chassis system contact.
Syntax:
Options:
MasterMM202-> showInventory
___________________________________
Leaf 101
-----------------------------------
GUID - 00066A00EC002712
Manufacturer Id - 00066A
Manufacturer Name - SST
Mfg Date/Time - 2009/04/09 10:00
Model - 12800-LF18
Part Number - 220052-004-B
Product Name - 12800 QDR 18P Leaf Module
Serial Number - USF1150920031
Version - 004-B
...
setBeacon [beacon]
[beacon]
1=on, 0=off.
-> setBeacon 0
setSystemContact [contact]
[contact]
System contact string.
Switch Command Line Interface
Groups and Commands
1-38
D000103-000 E
Sample Output:
NOTES: If the system contact is not specified, the current system contact is
displayed.
setSystemName
Allows the user to set/show the chassis system name.
Syntax:
Options:
Sample Output:
NOTES: If the system name is not specified, the current system name is displayed.
setSystemLocation
Allows the user to set/show the chassis system location.
Syntax:
Options:
Sample Output:
NOTES: If the system location is not specified, the current system location is
displayed.
-> setSystemContact [contact string]
setSystemName [name]
[name]
System name string
-> setSystemName [name string]
setSystemLocation [location]
[location]
System location string
-> setSystemLocation [location string]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-39
Network
ifShow
Displays information for all the network interfaces for the switch, including the management port and
the internal Ethernet network.
Syntax:
Options:
Sample Output:
NOTES: This routine displays the attached network interfaces for debugging and
diagnostic purposes. If ifName is given, only the interfaces belonging to that group
are displayed. If ifName is omitted, all attached interfaces are displayed.
routeShow
Displays the OOB LAN IP routes.
Syntax:
ifShow [ifName]
[ifName]
The network interface name.
-> ifShow
sbe0 (unit number 0):
Flags: (0x8063) UP BROADCAST MULTICAST ARP RUNNING
Type: ETHERNET_CSMACD
Internet address: 192.168.100.9
Broadcast address: 192.168.111.255
Internet address: 172.26.3.19
Broadcast address: 172.26.15.255
Netmask 0xfffff000 Subnetmask 0xfffff000
Net 0xc0a86000 Subnet 0xc0a86000
Ethernet address is 00:06:6a:01:99:c8
Metric is 0
Maximum Transfer Unit size is 1500
2524301 octets received
6604130 octets sent
28728 packets received
14310 packets sent
19665 broadcast packets received
31 broadcast packets sent
0 multicast packets received
0 multicast packets sent
routeShow
Switch Command Line Interface
Groups and Commands
1-40
D000103-000 E
Options:
Sample Output:
ping
Send ping packets to a specified host.
Syntax:
Options:
None.
-> routeShow
ROUTE NET TABLE
destination gateway flags Refcnt Use Interface
----------------------------------------------------------------------------
0.0.0.0 172.26.0.1 3 2 18966 sbe0
0.0.0.0 172.26.3.35 3 0 0 sbe0
127.1.0.0 127.1.1.2 101 0 0 sbe1
127.2.0.0 127.2.0.1 101 0 0 sbe1
172.26.0.0 172.26.3.35 101 0 0 sbe0
172.26.0.0 172.26.3.19 101 -1 0 sbe0
----------------------------------------------------------------------------
ROUTE HOST TABLE
destination gateway flags Refcnt Use Interface
----------------------------------------------------------------------------
127.0.0.1 127.0.0.1 5 3 14209 lo0
----------------------------------------------------------------------------
ping [ipAddress] [packetCount]
[IpAddress]
The IP address of the network host to ping.
[packetCount]
The number of packets with which to ping the host (default is 5).
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-41
Sample Output:
NOTES: This routine spawns a process to send ping packets to the specified IP
address. If packetCount is given, the process exits after that number of packets are
sent. If packetCount is ommitted, a default the number of packets defaults to 5.
ping6
Sends ping packets to a specified IPv6 address.
Syntax:
Options:
Sample Output:
-> ping 172.26.0.254
PING 172.26.0.254: 56 data bytes
64 bytes from 172.26.0.254: icmp_seq=0. time=0. ms
64 bytes from 172.26.0.254: icmp_seq=1. time=0. ms
64 bytes from 172.26.0.254: icmp_seq=2. time=0. ms
64 bytes from 172.26.0.254: icmp_seq=3. time=0. ms
64 bytes from 172.26.0.254: icmp_seq=4. time=0. ms
----172.26.0.254 PING Statistics----
5 packets transmitted, 5 packets received, 0% packet loss
round-trip (ms) min/avg/max = 0/0/0
ping6 [-n] [-q] [-v] [-c ] [-I ]
[-n]
Numeric output only.
[-q]
Only display summary lines.
[-v]
Verbose output.
[-c ]
The number of packets to ping the host with (default is 5).
[-I ]
The local interface name to use (useful for link local ping).
[ipv6Address]
The network host to ping, scoped address accepted.
-> ping6 ipv6Address
Switch Command Line Interface
Groups and Commands
1-42
D000103-000 E
NOTES: This routine spawns a process to send ping packets to the specified IPv6
address. If packetCount is given, the process exits after that number of packets are
sent. If packetCount is omitted, a default the number of packets defaults to 5.
showChassisIpAddr
Displays the chassis IP address.
Syntax:
Options:
Sample Output:
setChassisIpAddr
Change the OOB LAN IP address and network mask.
Syntax:
Options:
Sample Output:
NOTES: Changing the chassis IP address will drop the connection to the CLI if not
using the console port and may cause the device to become unreachable.
setChassisIpv6Addr
Changes the chassis IPv6 address.
Syntax:
showChassisIpAddr
None.
-> showChassisIpAddr
Chassis IP Address: 172.26.0.221 Net mask: 255.255.240.0
setChassisIpAddr -h ipaddress -m netMask
-h ipaddress
The new IP address in dotted notation format 'xxx.xxx.xxx.xxx'.
-m netMask
The network mask. (may be in dotted notation or hexidecimal format)
-> setChassisIpAddr -h 172.26.0.221 -m 255.255.240.0
setChassisIpv6Addr [ /]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-43
Options:
Sample Output:
NOTES: Changing the chassis IPv6 address may drop the connection to the CLI if
not using the console port, and may cause the device to become unreachable.
delChassisIpv6Addr
Deletes the chassis IPv6 address.
Syntax:
Options:
Sample Output:
NOTES: Changing the chassis IPv6 address may drop the connection to the CLI if
not using the console port, and may cause the device to become unreachable. This
command does not affect link-local or autoconfigured addresses.
showChassisIpv6Addr
Displays the chassis IPv6 address.
Syntax:
Options:
The new IPv6 address in notation format 'a:b:c:d:e:f:g:h', embedded 0s can be shortened,
eg a:b::g:h.
Network mask length. (0-128).
-> setChassisIpv6Addr
delChassisIpv6Addr
None.
-> delChassisIpv6Addr
showChassisIpv6Addr
None.
Switch Command Line Interface
Groups and Commands
1-44
D000103-000 E
Sample Output:
autoConfIPv6Enable
Enables IPv6 address autoconfiguration.
Syntax:
Options:
Sample Output:
NOTES: This command allows prefix learning from attached routers, and does not
affect link-local or manually configured addresses.
autoConfIPv6Disable
Disables IPv6 address autoconfiguration.
Syntax:
Options:
Sample Output:
NOTES: Prevents prefix learning from attached routers, and does not affect
link-local or manually configured addresses.
autoConfIPv6Show
Displays IPv6 address autoconfiguration setting(s).
Syntax:
-> showChassisIpv6Addr
autoConfIPv6Enable
None.
-> autoConfIPv6Enable
autoConfIPv6Disable
None.
-> autoConfIPv6Disable
autoConfIPv6Show
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-45
Options:
Sample Output:
ndpShow
Displays the IPv6 Neighbors table.
Syntax:
Options:
Sample Output:
showDefaultRoute
Displays the default gateway IP address.
Syntax:
Options:
Sample Output:
NOTES: This is the IP address for the default gateway to route packets from the
OOB mangement port to an external network.
setDefaultRoute
Change the default gateway IP address.
None.
-> autoConfIPv6Show
ndpShow
None.
-> ndpShow
showDefaultRoute
None.
-> showDefaultRoute
Gateway IP Address: 172.26.0.254
Switch Command Line Interface
Groups and Commands
1-46
D000103-000 E
Syntax:
Options:
Sample Output:
NOTES: This allows the user to configure the IP address for the default gateway
to route packets from the OOB management port to an external network.
arpShow
Displays the contents of the ARP table.
Syntax:
Options:
Sample Output:
hostShow
Displays a list of remote hosts names, internet address and alias(es).
Syntax:
setDefaultRoute -h ipaddress
-h ipaddress
The default gateway IP address in dotted decimal format (xxx.xxx.xxx.xxx).
setDefaultRoute -h 172.26.0.235
arpShow
None.
-> arpShow
LINK LEVEL ARP TABLE
destination gateway flags Refcnt Use Interface
--------------------------------------------------------------------------
127.1.1.1 02:06:6a:ff:ff:fd 405 3 12121958 sbe1
127.2.0.2 02:06:6a:ff:ff:fd c05 2 71421 sbe1
172.26.0.1 00:19:e8:a0:69:f9 405 1 0 sbe0
172.26.3.35 00:06:6a:01:99:c8 405 1 0 lo0
--------------------------------------------------------------------------
hostShow
Switch Command Line Interface
Groups and Commands
1-48
D000103-000 E
Sample Output:
-> hostShow
hostname inet address aliases
-------- ------------ -------
localhost 127.0.0.1 CHASSIS
slot1 127.1.0.1
slot2 127.1.0.2
slot3 127.1.0.3
slot4 127.1.0.4
slot5 127.1.0.5
slot6 127.1.0.6
slot7 127.1.0.7
slot8 127.1.0.8
slot9 127.1.0.9
slot10 127.1.0.10
slot11 127.1.0.11
slot12 127.1.0.12
slot13 127.1.0.13
slot14 127.1.0.14
slot15 127.1.0.15
slot16 127.1.0.16
slot17 127.1.0.17
slot18 127.1.0.18
slot19 127.1.0.19
slot20 127.1.0.20
slot21 127.1.0.21
slot22 127.1.0.22
slot23 127.1.0.23
slot24 127.1.0.24
slot25 127.1.0.25
slot26 127.1.0.26
slot27 127.1.0.27
slot28 127.1.0.28
slot29 127.1.0.29
slot30 127.1.0.30
slot31 127.1.0.31
slot32 127.1.0.32
slot33 127.1.0.33
slot34 127.1.0.34
slot35 127.1.0.35
slot36 127.1.0.36
mm1 127.1.1.1 switchA
mm2 127.1.1.2 switchB
Master 127.2.0.1
Slave 127.2.0.2
WRS-Template 172.26.3.35
home 10.32.2.150
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-49
dhcpEnable
Enable the DHCP client for this system.
Syntax:
Options:
Sample Output:
NOTES: Enables the DHCP client subsystem, requests a DHCP lease, and then
configures the interface with the lease data from the server,
dhcpDisable
Disable the DHCP client and release any acquired IP address
Syntax:
Options:
Sample Output:
NOTES: Any DHCP-acquired IP address will be released. The interface will then
be configured to the default static values from the current bootline.
dhcpShow
Display DHCP client information.
Syntax:
dhcpEnable
None.
MasterMM202-> dhcpEnable
DHCP is enabled
dhcpDisable
None.
MasterMM202-> dhcpDisable
DHCP is disabled
dhcpShow [-v]
Switch Command Line Interface
Groups and Commands
1-50
D000103-000 E
Options:
Sample Output:
dnsParamsShow
Displays the stored domain named server (DNS) parameters.
Syntax:
Options:
Sample Output:
dnsParamsSet
Changes the DNS configuration parameters.
Syntax:
-v verbose output
MasterMM202-> dhcpShow
Client state = BOUND
Assigned IP address: 172.26.3.35
Client subnet mask: 255.255.240.0
DHCP server: 172.26.1.20
Default IP router: 172.26.0.1
Client lease duration: 518400 secs (421299 remaining)
dnsParamsShow
None.
MasterMM202-> dnsParamsShow
DNS Resolver : Enabled
DNS Server Address : xxx.xxx.xxx.xxx
Local Domain Name : st.qlogic.com
NOTE:
This command retrieves the stored configuration parameters used for
domain name resolution.
dnsParamsSet [-s ] [-d ] [-e <1
or 0>]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-51
Options:
Sample Output:
-s
DNS server IP address in dotted notation format (xxx.xxx.xxx.xxx)
-d
The local domain name where this switch is installed (limit 32 chars).
-e <1 or 0>
1 = enable the DNS resolver, 0 = disable the DNS resolver.
dnsParamsSet -e 0
MasterMM202-> dnsParamsShow
DNS Resolver : Disabled
DNS Server Address : xxx.xxx.xxx.xxx
Local Domain Name : st.qlogic.com
NOTE:
The DNS resolver cannot be enabled until both the server address and local
domain name have been configured. It is necessary to manually reboot the
switch in order to start or stop the DNS resolver.
Switch Command Line Interface
Groups and Commands
1-52
D000103-000 E
Firmware
fwUpdate (12300)
Updates the firmware.
Syntax:
Options:
Sample Output:
NOTES: Firmware update works by using ftp to retrieve the firmware file, then writes
the file to flash. Omitting any of the options causes the user to be prompted for the
information.
fwUpdateSlot
Updates the firmware on a specific line card.
Syntax:
fwUpdate [host user password dir filename]
host
The name of the host where the firmware file resides.
user
The FTP user name.
password
The FTP user password.
dir
After logging in, the directory to cd to.
filename
The name of the firmware file.
-> fwUpdate
Enter 1 for FTP, 2 for local file: 1
Ftp Server IP Address:[192.168.0.195]
Ftp username:[ftp] xxxxx
Ftp password:[ftp] xxxxx
File Directory:[PATH TO FIRMWARE FILE]
File name:[xxx.pkg]
fwUpdateSlot slotnumber [host user password dir
filename]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-53
Options:
Sample Output:
NOTES: Firmware update works by using ftp to retrieve the firmware file, then writes
the file to flash. Omitting any of the options causes the user to be prompted for the
information.
fwUpdateChassis
Updates the firmware for all cards in a chassis of a particular type, or everything.
Syntax:
Options:
slotnumber
The chassis slot numberto update.
[host]
The name of the host where the firmware file resides.
[user]
The FTP user name.
[password]
The FTP user password.
[dir]
After logging in, the directory to cd to.
[filename]
The name of the firmware file.
-> fwUpdateSlot 1
Enter 1 for FTP, 2 for local file: 1
Ftp Server IP Address:[192.168.0.195]
Ftp username:[ftp] xxxxx
Ftp password:[ftp] xxxxx
File Directory:[PATH TO FIRMWARE FILE]
File name:[xxxx.pkg]
fwUpdateChassis (all,management,evic, fvic) [noprompt]
[reboot]
(all,management,evic, fvic)
Type of card to update. See notes for details.
[noprompt]
Will not prompt the user for ftp information (uses the saved values).
[reboot]
Upon successful completion, reboots the updated cards .
Switch Command Line Interface
Groups and Commands
1-54
D000103-000 E
Sample Output:
NOTES: Firmware update works by retrieving the firmware file from an ftp server.
The file is saved locally and then written to flash. Using the ’all’ option, all cards in
the chassis will be updated. This assumes that all firmware files are in the same
location. The user will be prompted for the names of each file for each line card type
present. The system can save the values entered as defaults for future firmware
updates.
fwListFiles
Lists the contents of the firmware directory.
Syntax:
Options:
Sample Output:
NOTES: The firmware directory temporarily stores firmware files before they are
written to flash.
fwShowUpdateParams
Display the default update firmware settings.
Syntax:
Options:
-> fwUpdateChassis all reboot
fwListFiles
None.
-> fwListFiles
Listing Directory /firmware:
[PATH TO FIRMWARE FILE] / [FIRMWARE FILE NAME]
fwShowUpdateParams
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-55
Sample Output:
fwSetUpdateParams
Change the default update firmware settings.
Syntax:
Options:
NOTES: Modifies the default update firmware parameters. Except for the filename
option, all parameters are shared across all card types. The cardtype parameter is
only required when specifying the filename.
showCapability
Display capability and feature information for a specific release.
Syntax:
-> fwShowUpdateParams
Firmware update ftp configuration settings:
host:[0.0.0.0]
user:[ftp]
password:[ftp]
directory:[]
filename management:[]
filename evic:[]
filename fvic:[]
fwSetUpdateParams -c cardtype [-h hostname] [-u
username] [-p password] [-d directory] [-f filename]
-c - cardtype
Choices are: 'management', 'fvic', 'evic'
-h - hostname
The host name or IP address of the FTP server.
-u - username
The name of the user accessing the ftp server.
-p - password
The password of the user accessing the ftp server.
-d - directory
The directory containing the firmware file.
-f - filename
The firmware file name.
showCapability [-key feature]
Switch Command Line Interface
Groups and Commands
1-56
D000103-000 E
Options:
Sample Output:
showLastScpRetCode
Display the return code from the last SCP Firmware Push.
Syntax:
Options:
Sample Output:
NOTES: This allows for automated systems to determine if a SCP firmware push
was successful or not.
fwVersion
Displays the firmware versions for a unit.
Syntax:
Options:
[-key feature]
Displays information for a particular feature.
-> showCapability
fwPush: 1
showLastScpRetCode slot | -all
slot
The slot number in the chassis.
-all
All slots in the chassis.
-> showLastScpRetCode 101
SCP: Slot 101 Last Exit Code: 0: Success
fwVersion [slot]
slot
Slot number.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-57
Sample Output:
bootQuery
Displays boot image version information.
Syntax:
Options:
Sample Output:
bootSelect
Select the next boot image to be used.
Syntax:
Management Module 201 Information -----------------
Firmware Version: 5.0.0.0.73
Firmware build: 5_0_0_0_73
Firmware BSP: xt3
MBC Version: None
Bootrom Version: 5.0.0.0.57
bootQuery [slot] [-active | -alternate | -all]
[slot]
Slot number.
[-active]
Displays the version of the active firmware image.
[-alternate]
Displays t]he version of the alternate firmware image.
[-all
Displays the versions for the primary and alternate firmware images.
MasterMM202-> bootQuery 201
Primary firmware version: 5.0.0.0.73
bootSelect [slot] [-i index] [-alternate] [-version
version] [-noprompt]
Switch Command Line Interface
Groups and Commands
1-58
D000103-000 E
Options:
Sample Output:
NOTES: This command allows the user to set the next boot image for the device.
A '*' next to the image entry indicates the currently selected bootimage. A '#'
indicates the currently active boot image.
[slot]
The slot number using the next boot image.
[-i index]
The index of the boot image to be used next.
[-alternate]
Chooses the alternate image to be used next.
[-version version]
Chooses a specific version to be the image to be used next.
[-noprompt]
Displays the current configuration only.
MasterMM202-> bootSelect 201
Currently installed firmware versions
index : alias : version
--------------------------
*# 1 : image1 : 5.0.0.0.73;
2 : image2 : 5.0.0.0.72;
* - indicates Primary image (will run at next reboot)
# - indicates Active image
Default boot image index = 1
...
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-59
Subnet Management
smControl
Starts and stops the embedded subnet manager.
Syntax:
Options:
Sample Output:
smConfig
Configure startup parameters of the embedded subnet manager.
Syntax:
Options:
Sample Output 1:
smControl start | stop | restart | status
Start
Start the SM.
Stop
Stop the SM.
restart
Restarts the SM.
status
Prints out the SM Status.
-> smControl start
Starting the SM...
smConfig [query] [startAtBoot yes|no] [startOnSlaveCmu yes|no]
query
Display present settings, no change
startAtBoot
Start the subnet manager at chassis boot
startOnSlaveCmu
Start subnet manager on the slave CMU
-> smConfig
Start at boot? [Y]
Start on slave CMU? [N]
Switch Command Line Interface
Groups and Commands
1-60
D000103-000 E
Sample Output 2:
NOTES: Use this command to configure the subnet manager. Changes to these
parameters do not take effect until the chassis management card(s) is rebooted.
This command is only available on the master chassis management card.
smShowLids
Displays the LID of the subnet manager.
Syntax:
Options:
Sample Output:
NOTES: Use this command to display the current LID of the subnet manager.
-> smconfig startAtBoot yes startOnSlaveCmu yes
Saving....
Saving complete...
smShowLids
None.
sm_state = MASTER count = 572781 LMC = 0, Topology Pass count = 339, Priority = 0, Mkey = 0x0
-----------------------------------------------------------------------------------------
QLogic 12300 GUID=0x00066a00da000000 172.26.2.2 MM 1, Ch
-----------------------------------------------------------------------------------------
Node[ 0] => 00066a000600013c (2) ports=24, path=
Port ---- GUID ---- (S) LID LMC _VL_ __MTU__ _WIDTH_ ____SPEED____ CAP_MASK N# P#
0 00066a000600013c 4 LID=0001 LMC=0000 8 8 2k 2k 4X 4X 2.5 2.5 00000a4a 0 0
4 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 1
22 4 22
5 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 1
23 4 23
6 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 1
24 4 24
7 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 2
24 7 24
8 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 2
23 7 23
9 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 2
22 7 22
22 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 3
16 22 16
23 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 3
18 22 18
24 0000000000000000 4 8 8 2k 2k 4X 4X 2.5/5 5.0 00000000 3
17 22 17
...
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-61
smPriority
Display the priority of the embedded subnet manager.
Syntax:
Options:
Sample Output 1:
NOTES: The priority of the Subnet Manager (SM) determines which subnet
manager will become the master SM for the fabric. Zero is the lowest priority and
fifteen is the highest. The SM with the highest priority becomes the master SM for
the fabric. The elevated priority value determines what the priority of the SM will be
if it becomes the Master. This allows persistent failovers that do not automatically
fail back by configuring the elevated priority to be higher than all normal priorities.
This feature is effectively disabled when set to the default of zero. The subnet
manager must be running to display the priority.
smSweepRate
Display or dynamically set the sweep rate of the subnet manager.
Syntax:
Options:
Sample Output:
smPriority
None.
-> smPriority
The SM Priority is 0
smSweepRate [sweepRate]
sweepRate
The sweep rate (in seconds) of the subnet manager. Valid values are 3-86400, or 0 to turn
the sweep off. The sweepRate is the interval between the end of one sweep and the start of
the next sweep.
-> smSweepRate 300
The SM sweep rate has been set to 300 seconds
Switch Command Line Interface
Groups and Commands
1-62
D000103-000 E
NOTES: The sweep rate determines how often the subnet manager scans the fabric
for changes and events. The subnet manager must be running to display or
dynamically set the sweep rate of the embedded subnet manager. Changes to
sweepRate made with the smSweepRate command will only affect the subnet
manager that is currently running and will not be persistent.
smForceSweep
Force a fabric sweep by the embedded subnet manager.
Syntax:
Options:
Sample Output:
NOTES: Use this command to force a sweep by the subnet manager.
bmForceSweep
Force a fabric sweep by the embedded baseboard manager.
Syntax:
Options:
Sample Output:
NOTES: Use this command to force a sweep by the baseboard manager.
smShowGroups
Display multicast group information in the embedded subnet manager.
Syntax:
smForceSweep
None.
-> smForceSweep
bmForceSweep
None.
-> bmForceSweep
smShowGroups [-h]
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-63
Options:
Sample Output:
NOTES: Use this command to display multicast group information in the subnet
manager. This command is not available unless the subnet manager is in the Master
mode.
smShowServices
Display subnet administration service records of the subnet manager.
Syntax:
Options:
-h
Display the host name as part of the output.
-> smShowGroups
Multicast Groups:
join state key: F=Full N=Non S=SendOnly Member
0xff12601bffff0000:00000001ffffd5bb (c001)
qKey = 0x00000000 pKey = 0xFFFF mtu = 4 rate = 3 life = 19 sl = 0
0x0011750000ffd5bb F
0xff12401bffff0000:00000000ffffffff (c000)
qKey = 0x00000000 pKey = 0xFFFF mtu = 4 rate = 3 life = 19 sl = 0
0x00066a01a0007116 F 0x0002c902003fffd5 F 0x00066a00a00001ac F
0x00066a01a000015d F 0x00066a00a00001a3 F 0x00066a00a00001dc F
0x00066a00a000035a F 0x0011750000ffd5c2 F 0x0011750000ffd664 F
0x0011750000ffd9c2 F 0x0011750000ffd9f8 F 0x0011750000ffd5b9 F
0x0011750000ffda4a F 0x0011750000ffd5bb F 0x0011750000ffd9de F
smShowServices
None.
Switch Command Line Interface
Groups and Commands
1-64
D000103-000 E
Sample Output:
NOTES: The components(fields) of each service record are displayed. Each service
record is stored in a location identified by a 'Slot' number which is displayed before
any component of that Service Record. If a group of slots do not contain Service
Records, the first slot of the empty group is displayed as 'empty'. This command is
not available unless the subnet manager is in the Master mode.
smShowSubscriptions
Display event forwarding (subscription) table in the embedded subnet manager.
Syntax:
Options:
-> smShowServices
******************************************************************
There is 1 Service Records
*********************************************************
Service ID = 0x1100D03C34834444
Service GID = 0xFE80000000000000:00066A000600013C
Service P_Key = 0x0000
Service Lease = infinite
Service Key =
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00
Service Name = QLogic Fabric Executive service Rev 1.1
Service Data 8 =
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00
Service Data 16 =
0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
Service Data 32 =
0x0000 0x0000 0x0000 0x0000
Service Data 64 =
0x0000000000000000 0x0000000000000000
Service Expire Time = 0x0100000000000000
smShowSubscriptions
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-65
Sample Output:
NOTES: Use this command to display the event forwarding (subscription) table in
the subnet manager. This command is not available unless the subnet manager is
in the Master mode.
smMasterLMC
Display the LMC value of the subnet manager to be used on CA ports.
Syntax:
Options:
-> smShowSubscriptions
******************************************************************
There are 2 subscriptions
******************************************************************
Subscriber GID = 0xFE80000000000000:00066A00D8000163
Subscriber LID = 0x0071
Subscriber PKey = 0xFFFF
Subscriber Start LID = 0x0001
Subscriber End LID = 0xBFFF
Subscriber Record ID = 0x00000001
Subscriber Inform Info =
GID = 0x0000000000000000:0000000000000000
Start LID = 0xFFFF
End LID = 0x0000
Is Generic? = Yes
Subscribe? = Subscribe
Type = All Types
Trap Number = 0x0040
Queue Pair Number = 0x000001
Response Time Value = 19
Producer Type = Subnet Management
******************************************************************
Subscriber GID = 0xFE80000000000000:00066A01A0007116
Subscriber LID = 0x0007
Subscriber PKey = 0xFFFF
Subscriber Start LID = 0x0001
Subscriber End LID = 0xBFFF
Subscriber Record ID = 0x00000036
Subscriber Inform Info =
GID = 0x0000000000000000:0000000000000000
Start LID = 0xFFFF
End LID = 0x0000
Is Generic? = Yes
Subscribe? = Subscribe
Type = All Types
Trap Number = 0x0043
Queue Pair Number = 0x000001
Response Time Value = 18
Producer Type = Channel Adapter
******************************************************************
There are 2 subscriptions
smMasterLMC
None.
Switch Command Line Interface
Groups and Commands
1-66
D000103-000 E
Sample Output:
NOTES: The value of the LMC determines how many LID's are assigned to an
endport; 2 LMC LIDs are assigned to endports based on this value. For example,
setting the LMC to a value of 3 will assign 8 LIDs per endport. The allowable LMC
values are between 0 and 7, inclusive. The subnet manager must be running as
MASTER to display the LMC value.
smShowMasterLid
Display the LID of the subnet manager.
Syntax:
Options:
Sample Output:
NOTE: Use this command to display the LID of the master subnet manager.
smShowLidMap
Display the LID-to-port GUID map for the subnet manager.
Syntax:
Options:
-> smMasterLMC
smShowMasterLid
None.
-> smShowMasterLid
The SM LID is 0x0001
smShowLidMap
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-67
Sample Output:
NOTES: Use this command to display the LID-to-port GUID map of the subnet
manager. This command is not available unless the subnet manager is in the Master
mode.
smShowMaxLid
Display the highest LID allocated by the subnet manager.
Syntax:
Options:
Sample Output:
NOTES: Use this command to display the highest LID allocated by the subnet
manager. This command is not available unless the subnet manager is in the Master
mode.
smSwitchLifetime
Allows the user to display/dynamically set the default switch lifetime of the subnet manager.
Syntax:
-> smShowLidMap
----------------------------------------------------------------------------------
SM is currently in the MASTER state, with Topology Pass count = 341
----------------------------------------------------------------------------------
Lid 0x0001: guid = 0x00066a000600013c, pass = 341, QLogic 12300 GUID=0x00066a00da000100
172.26.2.2 Spine 1, Ch
Lid 0x0002: guid = 0x00066a0007000170, pass = 341, QLogic 12300 GUID=0x00066a00da000100
172.26.2.2 Leaf 4, Chi
Lid 0x0003: guid = 0x00066a100600013c, pass = 341, QLogic 12300 GUID=0x00066a00da000100
172.26.2.2 Spine 1, Ch
Lid 0x0006: guid = 0x00066a00a0000248, pass = 229
Lid 0x0007: guid = 0x00066a01a0007116, pass = 341, st149
Lid 0x0008: guid = 0x0000000000000000, pass = 0
Lid 0x0028: guid = 0x0000000000000000, pass = 0
Lid 0x002a: guid = 0x0000000000000000, pass = 0
smShowMaxLid
None.
-> smShowMaxLid
The maximum LID is 0x0138
smSwitchLifetime [lifetime}
Switch Command Line Interface
Groups and Commands
1-68
D000103-000 E
Options:
Sample Output:
NOTES: The switch lifetime value determines the maximum time a packet may
remain within a switch, calculated using the formula: 4.096 * (2 switchlifetime) in
microseconds. The packet lifetime values may be between 0 and 31, inclusive. The
subnet manager must be running to display or dynamically set the default switch
lifetime. Changes will only affect the SM that is currently running and will not be
persistent.
smHoqLife
Display or dynamically set the head of queue packet lifetime for switch ports.
Syntax:
Options:
Sample Output:
NOTES: Use this command to display the maximum lifetime that a packet may
remain at the head of a virtual lane transmission queue before it is discarded by a
switch. Packet lifetime values are between 0 and 31, inclusive. These are calculated
using the formula: 4.096 * (2 ^ switchlifetime) in microseconds. The subnet manager
must be running to display, or to dynamically set the Hoq lifetime. Changes to Hoq
lifetime set with the smHoqLife command only affect the currently running SM and
will not be persistent.
lifetime
The packet lifetime value between 0 and 31, inclusive.
-> smSwitchLifetime 15
SM switch packet lifetime: 15 (~134217 microseconds)
smHoqLife [lifetime]
lifetime
The packet lifetime value between 0 and 31, inclusive.
-> smHoqLife 9
SM HOQ Liftime: 9 (~2097 microseconds)
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-69
smVLStall
Allows the user to display/dynamically set the VL stall value of the subnet manager.
Syntax:
Options:
Sample Output:
NOTES: Use this command to set the VL stall value for ports in the fabric. This
value determines the how quickly a virtual lane for a particular switch or endport
enters a 'stalled' state after dropping packets. The subnet manager must be running
to display or to dynamically set VLStall. Changes to VLStall with the smVLStall
command only affect the currently-running subnet manager and will not be
persistent.
smShowSMParms
Display subnet manager parameters switch lifetime, HOQ lifetime, VLStall val, pkt lifetime, and dynamic
PLT.
Syntax:
Options:
smVLStall [packets]
packets
The number of sequential packets dropped before port enters VL stalled state.
-> smVLStall 5
SM VL Stall Threshhold: 5 packets
smShowSMParms
None.
Switch Command Line Interface
Groups and Commands
1-70
D000103-000 E
Sample Output:
NOTES: Use this command to display a sampling of subnet manager parameters.
smPKeys
Configure a partition key (PKey) in the PKey table.
Syntax:
Options:
Sample Output:
NOTES: PKeys are used for partitioning the subnet. Only configure PKeys if the
host driver supports this. Invalid configuration of the PKey may render the fabric
inoperable. The subnet manager must be running to display PKeys.
smInfoKey
Set the subnet manager key (SMInfo) value.
Syntax:
Options:
-> smShowSMParms
SM priority is set to 4
SM LMC is set to 0
SM sweep rate is set to 300
SM max retries on receive set to 3
SM max receive wait interval set to 250 millisecs
switchLifetime set to 15
HoqLife set to 9
VL Stall set to 5
packetLifetime constant is set to 18
Dynamic PLT ON using values: 1 hop=16, 2 hops=17, 3 hops=17, 4 hops=18,
5 hops=18, 6 hops=18, 7 hops=18, 8+hops=19
SM DBSync interval set to 900
SM topology errors threshold set to 0, max retry to 3
smPKeys
None.
-> smPKeys
smInfoKey
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-71
Sample Output:
NOTES: Use this command to set the SM key. SM must be offline and key value is
up to 8 byte hex. The subnet manager must be running to display the SMInfo key
value.
smMgmtKey
Set the subnet manager management key (portInfo) value.
Syntax:
Options:
Sample Output:
NOTES: Use this command to set the SM management key. SM must be offline
and mkey value is up to 8 byte hex. The subnet manager must be running to display
the SMInfo key value.
smOptionConfig
Use this command to configure support for non-default modes of operation.
Syntax:
-> smInfoKey
SM Key: 0x0000000000000001 (1 decimal).
smMgmtKey
None.
-> smMgmtKey 0x11
SM management key: 0x0000000000000011 (17 decimal)
smOptionConfig [clear | default | [def-mcgrp-create]
[dyn-plt]]
Switch Command Line Interface
Groups and Commands
1-72
D000103-000 E
Options:
Sample Output:
NOTES: The subnet manager must be running to display the non-default modes of
operation.
smDefBcGroup
Displays the default multicast group configuration.
Syntax:
Options:
Sample Output:
NOTES: The subnet manager must be running to display default multicast group
information.
Valid MTU values are 1(256), 2(512), 3(1024), 4(2048), and 5(4096)
Valid RATE values are 2(2.5GB), 3(10GB), 4(30GB), 5(5GB), 6(20GB),
7(40GB), 8(60GB), 9(80GB), 10(120GB)
Valid Values for SL are 0 to 0xF
Valid Values for QKEY are 0 to 0xFFFFFFFF
Valid Values for FlowLabel are 0 to 0xFFFFF
clear
Clears all set options.
default
Enable the default set of options (i.e., def-mcgrp-create and dyn-pit).
def-mcgrp-create
Auto create default multicast group. If using only this option, dyn-pit will be disabled.
dyn-pit
Enable dynamic packet lifetimes for pathrecord queries. If using only this option,
def-mcgrp-create will be disabled.
-> smOptionConfig dyn-plt
[dyn-plt] Dynamic packet lifetime support is enabled
smDefBcGroup
None.
-> smDefBcGroup
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-73
Valid Values for TClass are 0 to 0xff
smGidPrefix
Set the Subnet Prefix (default=0xfe80000000000000).
Syntax:
Options:
Sample Output:
NOTES: Use this command to set the subnet prefix of the SM. The SM must be
offline and the subnet prefix value is 8 byte hex. The subnet manager must be
running to display default multicast group information.
smSubnetSize
Set/display the subnet size for the subnet manager.
Syntax:
Options:
Sample Output:
NOTES: Use this command to tune the SM to handle the configured fabric size.
The subnet manager must be running to display subnet size information.
smTopoErrorThresh
Set/display the error threshold for a topology sweep.
Syntax:
smGidPrefix [prefix]
None.
-> smGidPrefix
Subnet Prefix: 0xfe80000000000001
smSetSubnetSize
None.
-> smSubnetSize
smTopoErrorThresh
Switch Command Line Interface
Groups and Commands
1-74
D000103-000 E
Options:
Sample Output:
NOTES: Sets the maximum number of errors the SM may encounter during a sweep
before abandoning the sweep. The subnet manager must be running to display the
error threshold for a topology sweep.
smTopoAbandonThresh
Set/display the max consecutive times the SM can abandon a sweep due to too many errors.
Syntax:
Options:
Sample Output:
NOTES: The subnet manager must be running to display this information.
smMaxRetries
Displays the maximum number of subnet manager receive retries
Syntax:
Options:
None.
-> smTopoErrorThresh 100
Set topology error threshold to:100
smTopoAbandonThresh
None.
-> smTopoAbandonThresh 3
Set topology sweep abandonment threshold to:3
smMaxRetries
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-75
Sample Output:
NOTES: The subnet manager must be running to display this information.
smRcvWaitTime
Displays the maximum time (in milliseconds) to wait for a reply to a subnet manager packet.
Syntax:
Options:
Sample Output:
NOTES: The subnet manager must be running to display this information.
smNonRespDropTime
Displays the seconds to wait before dropping a non-responsive node.
Syntax:
Options:
Sample Output:
-> smMaxRetries 3
Set max retries to:3
-> smMaxRetries
Max retries: 3
smRcvWaitTime
None.
-> smRcvWaitTime 250
Set recieve wait time to: 250 milliseconds
-> smRcvWaitTime
Recieve wait time: 250 milliseconds
smNonRespDropTime
None.
-> smNonRespDropTime 300
Set Nonresponsive node drop time to: 300 seconds
-> smNonRespDropTime
Non-responsive node drop time: 300 seconds
Switch Command Line Interface
Groups and Commands
1-76
D000103-000 E
NOTES: The subnet manager must be running to display this information.
smNonRespDropSweeps
Displays the sweeps to wait before dropping a non-responsive node.
Syntax:
Options:
Sample Output:
NOTES: The subnet manager must be running to display this information.
smLogLevel
Displays or dynamically sets the Subnet Manager logging level.
Syntax:
Options:
Sample Output:
NOTES:
Levels: 1=WARN+, 2=INFINI_INFO+, 3=INFO+, 4=VERBOSE+, 5=DEBUG2+,
6=DEBUG3+, 7=TRACE+.
The subnet manager (SM) must be running to use this command. Changes made
with this command will only affect the currently running SM, and will be forgotten if
the FM is restarted or the chassis is rebooted. To make persistent changes edit the
FM XML configuration file.
smNonRespDropSweeps
None.
-> smNonRespDropSweeps 3
Set Nonresponsive node drop sweeps to: 3 sweeps
-> smNonRespDropSweeps
Non-responsive node drop sweeps: 3 sweeps
smLogLevel []
loglevel
logging level 1-7
-> smLogLevel 4
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-77
smLogMode
Displays or dynamically sets the Subnet Manager logging mode.
Syntax:
Options:
Sample Output:
NOTES:
0 - use normal logging levels
1 - logging is quieted by downgrading the majority of fatal, error, warn and infiniinfo
log messages to level
3 (INFO) and only outputting user actionable events when LogLevel is 1 or 2.
The Subnet manager must be running to use this command. Changes made with
this command will only affect the currently running SM, and will will be forgotten if
the FM is restarted or the chassis is rebooted. To make persistent changes edit the
FM XML config file.
smLogMask
Displays or dynamically sets the Subnet Manager logging mask for a specific subsystem.
Syntax:
Options:
Sample Output:
smLogMode []
logmode
logging mode 0 or 1
-> smLogMode 1
smLogMask []
subsystem
The Fabric Manager (FM) subsystem.
mask
The bit mask needed for logging to enable.
-> smLogMask SM
Switch Command Line Interface
Groups and Commands
1-78
D000103-000 E
NOTES:
Subsystems: CS, MAI, CAL, DVR, IF3, SM, SA, PM, PA, BM, FE, APP
The Subnet manager must be running to use this command. Changes made with
this command will only affect the currently running SM, and will will be forgotten if
the FM is restarted or the chassis is rebooted. To make persistent changes edit the
FM XML config file.
smMcLidTableCap
Displays the limit of the multicast LIDs that are available for allocation.
Syntax:
Options:
Sample Output:
NOTES: Setting this value to zero disables limiting multicast LIDs. The subnet
manager must be running to display this information.
smMcLidTableCap
None.
-> smMcLidTableCap 1024
Set mc lid limit to 1024
-> smMcLidTableCap
Mc lid limit: 1024
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-79
smMasterPingInterval
Displays the ping interval (in seconds) of the subnet manager.
Syntax:
Options:
Sample Output:
NOTES: Value must be between 3 and 10. The subnet manager must be running
to display this information.
smMasterPingFailures
Displays the number of allowable master ping failures.
Syntax:
Options:
Sample Output:
NOTES: Value must be between 2 and 5. The subnet manager must be running to
display this information.
smMasterPingInterval
None.
-> smMasterPingInterval 4
Set master ping interval to 3 seconds
-> smMasterPingInterval
Master ping interval: 4 seconds
smMasterPingFailures
None.
-> smMasterPingFailures 3
Set master ping failures to 3 failures
-> smMasterPingFailures
Master ping failures: 3 failures
Switch Command Line Interface
Groups and Commands
1-80
D000103-000 E
smDbSyncInterval
Displays how often a Master subnet manager should perform a full synchronization with the standby
subnet manager(s).
Syntax:
Options:
Sample Output:
NOTES: Value must be between 0 and 60 minutes (0=OFF). The subnet manager
must be running to display this information.
smDbSyncInterval
None.
-> smDbSyncInterval
SM DB full sync interval currently set to 15 minutes
-----SM DB SYNCHRONIZATION interval set to 900 seconds, 2 SM(s) in fabric-----
MASTER SM node at QLogic 12300 GUID=0x00066a00d90003fa, LID 0x0008, PortGuid
0x00066a00d90003fa
Sync Capability is SUPPORTED
STANDBY SM node at st44, LID 0x0100, PortGuid 0x00066a00a0000357
Sync Capability is SUPPORTED
Full sync status is SYNCHRONIZED
Time of last Full sync is THU APR 10 15:37:47 2008
Time of last INFORM records sync is THU APR 10 15:37:47 2008
Time of last GROUP records sync is THU APR 10 15:37:47 2008
Time of last SERVICE records sync is THU APR 10 15:37:47 2008
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-81
smDynamicPlt
Set/display dynamic packet lifetime values.
Syntax:
Options:
Sample Output:
NOTES: Setting values to numbers greater than 19 give an effectively-infinite packet
lifetime. The subnet manager must be running to display dynamic packet lifetime
values.
smDynamicPlt [index] [plt]
index
The index of the entry in the table to be changed. Range is 1-9..
plt
The packet lifetime value. The range is 0-63.
-> smDynamicPlt
Index: 1 PLT Value: 16 (~268435 usec)
Index: 2 PLT Value: 17 (~536870 usec)
Index: 3 PLT Value: 17 (~536870 usec)
Index: 4 PLT Value: 18 (~1073741 usec)
Index: 5 PLT Value: 18 (~1073741 usec)
Index: 6 PLT Value: 18 (~1073741 usec)
Index: 7 PLT Value: 18 (~1073741 usec)
Index: 8 PLT Value: 19 (~2147483 usec)
Index: 9 PLT Value: 19 (~2147483 usec)
Dynamic packet lifetime values for pathrecord queries are enabled
(use the smOptionConfig command to change)
-> smDynamicPlt 1 15
Index: 1 PLT Value: 15 (~134217 usec)
Index: 2 PLT Value: 17 (~536870 usec)
Index: 3 PLT Value: 17 (~536870 usec)
Index: 4 PLT Value: 18 (~1073741 usec)
Index: 5 PLT Value: 18 (~1073741 usec)
Index: 6 PLT Value: 18 (~1073741 usec)
Index: 7 PLT Value: 18 (~1073741 usec)
Index: 8 PLT Value: 19 (~2147483 usec)
Index: 9 PLT Value: 19 (~2147483 usec)
Dynamic packet lifetime values for pathrecord queries are enabled
(use the smOptionConfig command to change)
Switch Command Line Interface
Groups and Commands
1-82
D000103-000 E
sm1xLinkMode
Displays how the subnet manager handles 1x links.
Syntax:
Options:
Sample Output:
NOTES: When set to 'off', all links come up normally. When set to 'ignore', links that
only come up at 1x (when they were enabled for a higher rate) are forced down.
These downed ports can be queried to aid debugging errors in the fabric. The subnet
manager must be running to display this information.
smTrapThreshold
Display the port auto-disable urgent trap threshold value (in minutes).
Syntax:
Options:
Sample Output:
NOTES: When enabled, ports generating urgent traps at a rate higher than the
threshold will be disabled. This value can range from 10 to 100 traps/minute. Set
sm1xLinkMode
None.
-> sm1xLinkMode
Mode is 'off'. Erroneous 1x links will be activated normally.
-> sm1xLinkMode ignore
-> sm1xLinkMode
Mode is 'ignore'. Erroneous 1x links will not be activated.
smTrapThreshold
None.
-> smTrapThreshold
Trap Threshold is 0 (disabled).
-> smTrapThreshold 20
-> smTrapThreshold
Trap Threshold is 20 traps/minute.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-83
the value to 0 to disable this feature. The subnet manager must be running to display
this information.
smAppearanceMsgThresh
Displays the threshold for appearance and disappearance messages.
Syntax:
Options:
Sample Output:
NOTES: This command sets the threshold for the number of fabric appearance and
disappearance log messages that may be logged as NOTICEs per sweep by the
SM. A value of zero causes all such messages to be logged at the NOTICE level.
A value greater than zero will cause the priority of any subsequent messages to
be logged at the INFO priority. The subnet manager must be running to display this
information.
smPmBmStart
Allows the user to set/display whether performance manager and baseboard manager starts along with
the subnet manager.
Syntax:
Options:
smAppearanceMsgThresh
None.
-> smAppearanceMsgThresh
Message Threshold is 0 (disabled).
-> smAppearanceMsgThresh 3
-> smAppearanceMsgThresh
Message Threshold is 3 messages/sweep.
smPmBmStart [enable] [disable]
enable
Enable the start of the PM and BM at SM start-up.
disable
Disable the start of the PM and BM at SM start-up.
Switch Command Line Interface
Groups and Commands
1-84
D000103-000 E
Sample Output:
smShowRemovedPorts
Displays the ports that have been automatically removed from the fabric..
Syntax:
Options:
Sample Output:
NOTES: This displays ports that have been removed from the fabric automatically
by the SM, such as when a 1x link mode is set to 'ignore' or when a port has exceeded
its urgent trap threshold. This command is not available unless the subnet manager
is in Master mode.
smShowCounters
Display various statistics and counters maintained by the subnet manager.
Syntax:
Options:
-> smPmBmStart
SM is enabled
PM is enabled
BM is enabled
FE is enabled
-> smPmBmStart disable
SM is enabled
PM is disabled
BM is disabled
FE is enabled
smShowRemovedPorts
None.
-> smShowRemovedPorts
Disabled Ports:
Node 0x00066a0007000001: QLgoic 12300 GUID=0x00066a00da000001 Leaf 1,
Chip A
Port 12: Trap Threshold Exceeded
Port 23: 1x Link Width
smShowCounters
None.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-85
Sample Output:
NOTES: This command is not available unless the subnet manager is in Master mode.
smResetCounters
Resets various statistics and counters maintained by the subnet manager.
Syntax:
Options:
Sample Output:
pmShowCounters
Displays various statistics and counters about the performance manager (PM).
Syntax:
-> smShowCounters
COUNTER: THIS SWEEP LAST SWEEP TOTAL
------------------------------------ ---------- ---------- ----------
SM State transition to DISCOVERY: 0 0 2
SM State transition to MASTER: 0 0 1
SM State transition to STANDBY: 0 0 1
SM State transition to INACTIVE: 0 0 0
Total transmitted SMA Packets: 123 711 2181
Direct Routed SMA Packets: 123 711 2122
LID Routed SMA Packets: 0 0 40
SMA Query Retransmits: 0 0 18
SMA Query Retransmits Exhausted: 0 0 3
SM TX GET(Notice): 0 0 0
SM TX SET(Notice): 0 0 0
SM RX TRAP(Notice): 0 0 0
SM TX TRAPREPRESS(Notice): 0 0 0
SM TX GET(NodeDescription): 0 148 444
SM TX GET(NodeInfo): 0 148 444
SM TX GET(SwitchInfo): 0 6 18
...
smResetCounters
None.
-> smResetCounters
pmShowCounters
Switch Command Line Interface
Groups and Commands
1-86
D000103-000 E
Options:
Sample Output:
pmResetCounters
Resets various statistics and counters about the performance manager (PM).
Syntax:
Options:
Sample Output:
pmShowRunningTotals
Displays Running Total Counters for the performance manager (PM) for all ports in a fabric.
Syntax:
Options:
Sample Output:
bmPriority
Display the priority of the embedded baseboard manager.
Syntax:
None.
-> pmShowCounters
pmResetCounters
None.
-> pmResetCounters
pmShowRunningTotals
None.
-> pmShowRunningTotals
bmPriority
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-87
Options:
Sample Output:
NOTES: The priority of the Baseboard Manager (BM) determines which BM will
become the master BM for the fabric. The priority values are 0 (lowest) and 15
(highest). The BM with the highest priority becomes the master BM for the fabric.
The elevated priority value determines what the priority of the BM will be if it becomes
Master. This allows persistent failovers that do not automatically fail back by
configuring the elevated priority to be higher than all normal priorities. This feature
is effectively disabled when set to the default of zero. The subnet manager must be
running to display the priority.
pmPriority
Display the priority of the embedded performane manager.
Syntax:
Options:
Sample Output:
NOTES: The priority of the Performance Manager(PM) determines which PM will
become the master PM for the fabric. The priority values are 0 (lowest) and 15
(highest). The PM with the highest priority becomes the master PM for the fabric.
The elevated priority value determines what the priority of the PM will be if it becomes
Master. This allows persistent failovers that do not automatically fail back by
configuring the elevated priority to be higher than all normal priorities. This feature
is effectively disabled when set to the default of zero. The subnet manager must be
running to display the priority.
None.
-> bmPriority
The BM Priority is 0
The BM Elevated Priority is disabled
pmPriority
None.
-> pmPriority
The PM Priority is 0
The PM Elevated Priority is disabled
Switch Command Line Interface
Groups and Commands
1-88
D000103-000 E
smRestorePriority
Restore normal priorities from elevated states for the SM, BM, and PM.
Syntax:
Options:
Sample Output:
NOTES: This command restores the normal priorities of various subnet managers
after they have elevated their priority following a failover. Issuing this command
allows the 'unsticking' of a sticky failover. Issuing this command without arguments
will restore the normal priorities of the SM, BM, and PM.
smResetConfig
Resets the XML configuration for the embedded subnet manager (ESM) to factory defaults. This
command is only available on the Master chassis management card.
Syntax:
Options:
Sample Output:
smRestorePriority [sm | bm | pm | all]
sm
Restore normal SM priority
bm
Restore normal BM priority
pm
Restore normal PM priority
all
Restore normal priorities for the SM, BM and PM.
-> smRestorePriority
smResetConfig [-noprompt]
-noprompt
proceed with a configuration reset without a confirmation prompt.
-> smResetConfig
Proceed with configuration reset? [N] y
Default XML configuration file has been generated.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-89
smShowConfig
Displays the XML configuration file.
Syntax:
Options:
Sample Output:
NOTES: With no arguments, the XML configuration file timestamp and contents will
be displayed, one screen at a time. Enter Y or Enter at the prompt to continue
displaying command output. Enter N at the prompt to terminate the output. The
-infoOnly and -contentOnly flags will limit the information displayed. Use the
smShowConfig [-infoOnly | -contentOnly] [-noprompt]
-infoOnly
Displays the timestamp for the XML configuration file.
-contentOnly
Displays the contents of the XML configuration file.
-noprompt
Do not prompt to 'Continue' for each page of displayed output.
-> smShowConfig
Continue? [Y]
...
Switch Command Line Interface
Groups and Commands
1-90
D000103-000 E
-noprompt flag to send all output to the screen at once.This command is only
available on the Master Chassis management card.
Switch Command Line Interface
Groups and Commands
D000103-000 E
1-91
Log
logShow
Displays the log file.
Syntax:
Options:
Sample Output:
NOTES: This command displays the log file that is contained in RAM.
logShow
None.
-> logshow
W|2006/10/04 20:26:31.176U: Thread "Log" (0x8fdab3b0)
Log: Unable to Send Trap: 523:Bad:65535
W|2006/10/04 20:26:31.176U: Thread "CPU1" (0x1)
Fcpi: Target Device 1 (2e7 p1) NPort Id 0x0106d1: Connection Restored
W|2006/10/04 20:26:31.196U: Thread "Log" (0x8fdab3b0)
Log: Unable to Send Trap: 523:Bad:65535
W|2006/10/04 20:26:31.216U: Thread "CPU1" (0x1)
Fcpi: Target Device 2 (b31 p2) NPort Id 0x0106d2: Connection Restored
W|2006/10/04 20:26:31.236U: Thread "CPU1" (0x1)
Fcpi: Target Device 3 (d94 p3) NPort Id 0x0106d3: Connection Restored
W|2006/10/04 20:26:31.246U: Thread "Log" (0x8fdab3b0)
Log: Unable to Send Trap: 523:Bad:65535
W|2006/10/04 20:26:31.256U: Thread "CPU1" (0x1)
Fcpi: Target Device 6 (ac6 p6) NPort Id 0x0106d6: Connection Restored
W|2006/10/04 20:26:31.276U: Thread "Log" (0x8fdab3b0)
Log: Unable to Send Trap: 523:Bad:65535
W|2006/10/04 20:26:31.326U: Thread "Log" (0x8fdab3b0)
Log: Unable to Send Trap: 523:Bad:65535
W|2006/10/04 20:28:29.912U: Thread "tTelnetd" (0x8fe143e0)
Osa: telnetd: connection requested by 192.168.0.107
W|2006/10/04 20:46:26.113U: Thread "tTelnetd" (0x8fe143e0)
Osa: telnetd: connection requested by 192.168.0.107
W|2006/10/05 19:37:08.727U: Thread "tTelnetd" (0x8fe143e0)
Osa: telnetd: connection requested by 192.168.0.46
W|2006/10/05 20:19:20.101U: Thread "tTelnetd" (0x8fe143e0)
Switch Command Line Interface
Groups and Commands
1-92
D000103-000 E
logClear
Clears the log file.
Syntax:
Options:
Sample Output:
NOTES: This command deletes all entries in the log file.
logConfigure
Configures the log settings.
Syntax:
Options:
logClear [-noprompt]
-noprompt
delete all log messages without prompting the user
-> logClear
Ram Log cleared
logConfigure
None.