Fujitsu XG2600 Hardware Manual
Text of the manual
XG2600 Hardware Guide
2
Preface
You have purchased the XG2600, a compact, 26 port 10 Gigabit Ethernet layer 2 switch that achieves unsurpassed standards
of high throughput and low-latency performance.
This manual explains the procedures required to install your XG2600 and should be read and understood before you start
using your XG2600.
First edition: February 2011
This manual contains the technology regulated by "Foreign Exchange and Foreign Trade Control Law."
Therefore when this manual is exported or provided to a nonresident, the appropriate permission based on this law is
required.
Screenshots are used according to the guidelines provided by Microsoft Corporation.
Copyright FUJITSU LIMITED 2011
XG2600 Hardware Guide
3
LICENSE AGREEMENT
Thank you for purchasing the XG Series switch product ("Hardware") and accompanying software ("Software," together
with Hardware, collectively, referred to as "Product") manufactured by Fujitsu Limited ("Fujitsu"). The use of the Product
is subject to Customer's acceptance of the terms and conditions of the following requirements ("Use Requirements").
Please note that Customer's use, installation or backup of the Product constitutes your acceptance of the following Use
Requirements. Please keep this License Agreement in a secure location as it will not be re-issued.
1.
Use and Copyright of the Software
Customer may use the Software solely in connection with the single Hardware that Customer has purchased.
The total number of Hardware that Customer can use in connection with the Software is limited to the number of license
specified above. Customer needs to purchase an additional license from Fujitsu in order to use the Software in connection
with additional unit of the XG Series switch product or other functions. Customer acquires only right to use the Software
by purchasing, this Software is copyrighted by Fujitsu or the third party that developed the software used in the Software.
2.
Transfer
Customer may not assign, transfer, lease, relicense or sublicense the Software or any rights in or to the Software to third
parties. Customer further agrees to keep the Software free and clear of any and all claims, liens, security interests and other
encumbrances.
3.
Modification
Customer may not modify, disassemble, decompile or reverse engineer the Software.
4.
Scope of Warranty
1) If Customer notifies Fujitsu of any discrepancy between the manual, user guides or other related documents
("Documentation") and the Software, Fujitsu shall, at its sole discretion, correct or provide information relating to such
correction free of charge within ninety (90) days of Customer's purchase of the Product ("Warranty Period").
2) During the Warranty Period, if the said discrepancy between the Documentation and the Software cannot be corrected
despite Fujitsu's repeated corrections or provision of information within reasonable limits as set forth in subsection (1)
above, Fujitsu shall be liable for damages incurred to Customer by reason of such discrepancy.
Fujitsu's aggregate liability for such damages shall not exceed the amount equal to the total price of the Product.
Further, Fujitsu shall not be liable for (i) damages to the extent they are caused by conditions not attributable to Fujitsu, or
(ii) any damages caused by special conditions such as indirect, incidental, special, consequential or punitive damages, or
damages for loss of profits, revenue, business, savings, data, use or cost of substitute procurement, incurred by Customer
or any third party, even if Fujitsu has been advised of the possibility of such damages or even if such damages are
foreseeable.
3) In the event a third party files a lawsuit, an appeal, a claim, or similar action ("Claim") against Customer alleging that the
Software infringes any patent, copyright, trademark, trade secret or any other intellectual property right ("Intellectual
Property Rights") of such third party, upon Customer's request and Customer's delegation of its rights to Fujitsu, Fujitsu
shall assume control of the defense and settlement of any such Claim at its sole cost and responsibility.
In such event, Fujitsu will pay for damages and expenses attributable to such Claim.
4) If it is determined in a final judgment or settlement that the Software infringes Intellectual Property Rights of a third party
as described in subsection (3) above, Fujitsu shall take any one of the measures described below at its sole discretion:
a.
modify the Software to be non-infringing;
b. obtain permission from third parties so that the Customer can use the Software; or
Product Name
XG Series Basic Software
Total number of licenses
1
XG2600 Hardware Guide
4
c.
if in Fujitsu's sole judgment it is not commercially reasonable to perform either of the above options, subject to the
limitation of liability set forth in subsection (2) above, Fujitsu shall pay for any damages Customer has incurred
due to nonuse of the Software.
5) If the Claim described in subsection (3) above is withdrawn based on the determination that the Software does not infringe
the Intellectual Property Rights of a third party, or that the Intellectual Property Rights of a third party are invalid, the
expenses incurred by the Customer or Fujitsu in dealing with such Claim shall be equally divided between Customer and
Fujitsu.
6) Except as otherwise expressly set forth above, Fujitsu shall not be liable for any damages (including, but not limited to,
loss of profits, suspension of operations, loss of business-related information, or other monetary damages) arising out of
the use or nonuse of the Product, even if Fujitsu has been advised of the possibility of such damages in advance.
7) If the Software contains software developed by a third party vendor, the warranty with respect to such third party software
is limited to those warranties provided by Fujitsu hereunder, and the third party vendor does not provide any further
warranties with respect to such third party software.
5.
High Safety Required Use
The Customer acknowledges and agrees that the Software is designed, developed and manufactured as contemplated for
general use, including without limitation, general office use, personal use, household use, and ordinary industrial uses, but
is not designed, developed and manufactured as contemplated for use accompanying fatal risks or dangers that, unless
extremely high safety is secured, could lead directly to death, personal injury, severe physical damage or other loss
(hereinafter "High Safety Required Use"), including without limitation, nuclear reaction control in nuclear facility, aircraft
flight control, air traffic control, mass transport control, medical life support system, and missile launch control in weapon
system.
The Customer shall not use the Software without securing the sufficient safety required for the High Safety Required Use.
In addition, Fujitsu shall not be liable against the Customer and/or any third party for any claim or damages arising in
connection with the High Safety Required Use of the Software.
FUJITSU LIMITED
XG2600 Hardware Guide
Contents
5
Contents
Preface ................................................................................................................................................................2
LICENSE AGREEMENT ..................................................................................................................................3
Organization and Usage of This Manual ............................................................................................................7
About This Manual ....................................................................................................................................................7
Target Readers and Required Knowledge .................................................................................................................7
Areas Covered ............................................................................................................................................................7
Trademark Notification in This Manual ....................................................................................................................8
How the Manuals for This Device Are Organized ....................................................................................................9
Safety Precautions .............................................................................................................................................10
About Warning Descriptions ...................................................................................................................................10
Notes on Maintenance ..............................................................................................................................................13
Precautions for Use ..................................................................................................................................................13
Eliminating Static Electricity from Twisted Pair Cables (Grounding) ....................................................................13
Ensuring Security .....................................................................................................................................................13
Cleaning ...................................................................................................................................................................13
Electromagnetic Compatibility (USA) ....................................................................................................................14
Electromagnetic Compatibility (CANADA) ........................................................................................................... 14
Electromagnetic Compatibility (EU) .......................................................................................................................14
Safety .......................................................................................................................................................................14
High safety ...............................................................................................................................................................14
Laser Safety .............................................................................................................................................................15
Notes on Rack Mounting and Connecting a Powerstrip ..........................................................................................15
About Fujitsu's Green Products ...............................................................................................................................15
Notes on Use .....................................................................................................................................................16
Chapter 1
Getting Started ....................................................................................... 17
1.1
Items in the Package, Descriptions and Functions ................................................................................18
1.1.1
Parts List ..................................................................................................................................................18
1.1.2
Installation of Switch: Front Access or Rear Access (User Configured Airflow) ...................................19
1.1.3
Switch Fan Unit Side ...............................................................................................................................20
1.1.4
Switch Port Side .......................................................................................................................................22
1.1.5
Top Surface ..............................................................................................................................................25
1.1.6
BOTTOM Surface ....................................................................................................................................26
1.2
Option ....................................................................................................................................................27
1.2.1
SFP+ Modules ..........................................................................................................................................27
Chapter 2
Installation .............................................................................................. 28
2.1
Requirements for Installation Environment ...........................................................................................29
2.1.1
Installation Requirements ........................................................................................................................29
2.1.2
Space Requirements .................................................................................................................................30
2.2
Installation of the switch ........................................................................................................................31
2.2.1
Decide Switch Access Configuration ...................................................................................................... 31
2.2.2
Rear-Access Configuration (Factory Default) .........................................................................................35
2.2.3
Change Switch Access Configurations from Rear-Access (Factory Default)
to Front-Access and Install ......................................................................................................................38
2.3
Connecting the Equipment .....................................................................................................................44
2.3.1
Discharging Twisted Pair Cable ..............................................................................................................44
2.3.2
Cleaning SFP+ Module / Optical Connector ...........................................................................................44
2.3.3
Connecting Twisted Pair Cable / SFP+ Module ......................................................................................46
XG2600 Hardware Guide
Contents
6
2.3.4
Plugging in the USB Memory ..................................................................................................................50
2.4
Connecting a Setup PC ..........................................................................................................................51
2.5
Time Setting ...........................................................................................................................................55
2.6
Set up IP address ....................................................................................................................................56
Index............................................................................................................................. 57
XG2600 Hardware Guide
7
Organization and Usage of This Manual
This manual explains what you need to know before using this device.
In addition, the README file on CD-ROM contains important information. You will also need to read the file.
About This Manual
This manual contains important information required to use this device safely.
Read this manual thoroughly before using this device. In particular, you must read and fully understand the "Safety
Precautions" described in this manual before using this device. Furthermore, this manual should be kept in an easy-to-
access location for quick reference while using this device.
Fujitsu takes the utmost care to insure that our products can be used safely without causing injury to the customer or
damage to their property
Target Readers and Required Knowledge
This manual is intended for persons who perform network management.
To use this manual, basic knowledge of network and the Internet is required.
Areas Covered
The organization of this manual and the contents of each chapter are shown as follows.
About the Symbols
The symbols used in this manual have the following meanings.
Chapter Titles
Contents
Chapter 1 Getting Started
This chapter lists the items that should be in the product package, and describes the names
and functions of the various components.
Chapter 2 Installation
This chapter describes how to install the switch and connect it to Console PC.
Indicates useful information for using this device.
Indicates precautions that must be taken when using this device.
Indicates additional information to complement operating instructions.
Indicates related matters such as operation procedures, etc.
Indicates the available model name when using functions of this device.
Indicates warning matters related to the Product Liability (P.L.) Law. Please follow them
when using this device.
Indicates cautionary notes related to the Product Liability (P.L.) Law. Please follow them
when using this device.
Hint
Precautions
Note
Reference
Available Model
Warning
Caution
XG2600 Hardware Guide
8
Trademark Notification in This Manual
Microsoft, MS-DOS, Windows, Windows NT, Windows Server and Windows Vista are registered trademarks of the
Microsoft Corporation in the USA and other countries.
Adobe and Reader are trademarks or registered trademarks of Adobe Systems Incorporated in the USA and other
countries.
Netscape is a trademark of Netscape Communications Corporation in the USA.
UNIX is a registered trademark of Open Group in the USA and other countries.
Other company names and product names in this manual are trademarks or registered trademarks of their respective
companies.
Abbreviated Product Names
The product names used in this manual are abbreviated as follows.
Product name
Description in this manual
Microsoft® Windows® XP Professional operating system
Windows® XP
Microsoft® Windows® XP Home Edition operating system
Microsoft® Windows® Millennium Edition operating system
Windows® Me
Microsoft® Windows® 98 operating system
Windows® 98
Microsoft® Windows® 95 operating system
Windows® 95
Microsoft® Windows® 2000 Server Network operating system
Windows® 2000
Microsoft® Windows® 2000 Professional operating system
Microsoft® Windows NT® Server network operating system Version 4.0
Windows NT® 4.0
Microsoft® Windows NT® Workstation operating system Version 4.0
Microsoft® Windows Server® 2003, Standard Edition
Windows Server® 2003
Microsoft® Windows Server® 2003 R2, Standard Edition
Microsoft® Windows Server® 2003, Enterprise Edition
Microsoft® Windows Server® 2003 R2, Enterprise Edition
Microsoft® Windows Server® 2003, Datacenter Edition
Microsoft® Windows Server® 2003 R2, Datacenter Edition
Microsoft® Windows Server® 2003, Web Edition
Microsoft® Windows Server® 2003, Standard x64 Edition
Microsoft® Windows Server® 2003 R2, Standard x64 Edition
Microsoft® Windows Server® 2003, Enterprise x64 Edition
Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
Microsoft® Windows Server® 2003, Enterprise Edition for Itanium-based systems
Microsoft® Windows Server® 2003, Datacenter x64 Edition
Microsoft® Windows Server® 2003 R2, Datacenter x64 Edition
Microsoft® Windows Vista® Ultimate operating system
Windows Vista®
Microsoft® Windows Vista® Business operating system
Microsoft® Windows Vista® Home Premium operating system
Microsoft® Windows Vista® Home Basic operating system
Microsoft® Windows Vista® Enterprise operating system
XG2600 Hardware Guide
9
How the Manuals for This Device Are Organized
The manuals for this device are organized as follows. Use these manuals as necessary.
Manual Name
Description
XG2600 Hardware Guide (This manual)
This manual describes the hardware of the XG2600.
User’s Guide
This manual describes a variety of operations and procedures, including the
installation and maintenance of the XG Series.
XG2600 Hardware Guide
10
Safety Precautions
About Warning Descriptions
This manual contains precautions that must be taken in order to use this device safely and prevent personal injury or
property damage. Please fully understand the meanings and contents of the following descriptions and symbols when
reading this manual.
The following symbols are used to indicate the type of warning or caution.
Indicates that improper use can cause severe damage to person, resulting in serious injury or
death.
Indicates that improper use can cause light or moderate injury.
In addition, this symbol indicates a chance of damage to this device and other connected
equipment.
Symbols
Definitions
The symbol in
form indicates a warning or cautionary note. Specific information is shown inside or
next to the symbol.
The symbol in
form indicates a prohibited (Do Not) action. Specific information is shown inside or
next to the symbol.
The symbol in
form indicates actions or instructions that must be followed. Specific information is
shown inside or next to the symbol.
Warning
Caution
XG2600 Hardware Guide
11
Always follow the instructions for safe use of this device. Indicates that improper use can cause
severe damage to person, resulting in serious injury or death.
Warnings
Do not insert or drop any foreign objects into the
device through the vent.
Also, prevent liquid such as water from entering
it.
In case a foreign object or liquid enters the
device, you must first unplug the power plug
from the socket and contact our engineer or an
engineer certified by Fujitsu.
Continuing to use the device in this condition
may result in electric shock, fire accident or
failure.
If you notice abnormal conditions such as
overheating, smoke emission, or odor, stop using
this device immediately, and pull the power cable
plug from the socket. Make sure that abnormal
conditions such as smoke no longer exist and
contact our engineer or an engineer certified by
Fujitsu.
Continuing to use the device in this condition
may result in electric shock or fire.
Disconnect 2 power supply cords before service
to avoid electric shock.(Except for active
maintenance)
Do not score, cut, or rework the power cable.
Do not put any objects on the power cable. The
power cable should not be pulled, bent forcibly,
twisted or heated. These actions may damage the
cable.
Do not use the power cable while it is bundled
together. Otherwise electric shock or fire may
occur.
The same applies to other cables.
For interface connectors, do not insert a
connector other than the appropriate connector
for a specific line.
Failure to follow this may result in electric shock
or failure.
If there is lightning near the location, do not
touch this device, the power cable or other cables.
Failure to follow this may result in electric shock.
The plastic sheets used for packaging must be
kept out of reach of children so that they cannot
put the sheets in their mouths or put their heads
into them.
Failure to follow this may result in suffocation.
Do not connect or disconnect the power plug with
wet hands.
Failure to follow this may result in electric shock.
When cleaning, do not use cleaning sprays (that
includes inflammable material) because it may
cause device breakdown or fire.
The cover must only be opened by qualified
service personnel.
Also, the power cable must be unplugged during
maintenance.
Failure to follow this may result in electric shock.
Do not use this device when the power cable or
plug is damaged or the socket is loose.
Continuing to use the device in this condition
may result electric shock or fire.
Also, keep removed screws out of reach of
children so that they cannot put the screws into
their mouths accidentally.
In the event they put the screws into their mouths,
consult a doctor immediately.
Do not disassemble, dismantle, modify or
reproduce this device.
Failure to follow this may result in electric shock,
fire or failure.
You cannot use this device at a voltage other than
the indicated supply voltage.
Do not overload the electric outlet.
Failure to follow these warnings may result in
electric shock or fire.
Warning
XG2600 Hardware Guide
12
Indicates that improper use can cause light or moderate injury.
In addition, this symbol indicates a chance of damage to this device and other connected equipment.
Cautions
Do not touch this device for more than one
minute while it is turned on.
Failure to follow this may cause low-temperature
burns.
Do not put objects on this device or use it as a
work area.
Failure to follow this may cause damage to the
device, or result in injury to person or failure.
Do not stand this device vertically or stack it.
Failure to follow this may cause the device to fall
over causing injury, damage, or failure.
Install this device indoors.
Installing outdoors may result in failure.
Do not install this device on shaky stands, unlevel
surfaces, or other unstable places.
In addition, do not use this device in a location where
impact or vibration occurs.
Failure to follow this may result in the device falling
over, causing injury, damage, or failure.
Do not use this device in places where the
temperature is extremely high/low or fluctuates
greatly.
Failure to follow this may cause system failure.
Follow the operating temperature limit for this
device.
Do not use the device in a corrosive gas
environments or other places where it may be
exposed to chemical substances.
Failure to follow this may cause damage or
failure.
Do not use this device near a microwave oven or
other equipment that emits strong magnetic
fields.
Failure to follow this may cause system failure.
Ensure enough space for access to, and cabling
of, the device
For multiple devices ensure adequate service
areas, front and back, for both devices.
Failure to follow this may cause cable failures.
Make sure to unplug the power cable when
transporting this device.
Failure to follow this may cause system fault.
Do not use any extension card other than the ones
supported by this device.
Failure to follow this may cause system failure.
Make sure to connect cables correctly.
Improper cabling hinders reliable communications
and may cause failure of the device.
Do not install this device near heaters or at places
subject to direct sunlight, humidity, and dust.
Electric shock or fire may occur.
Do not obstruct the device's air vents to avoid
higher operating temperatures
Failure to follow this may result in fire.
Unplug the power cable by pulling the plug with
your hand.
Electric shock or fire may occur due to a damaged
plug.
Insert the plug into the socket completely.
Not completely inserting the plug may result in
electric shock, smoke emitting or fire.
If dust or dirt accumulate on the metal contacts of
the power plug or device receptacle, wipe it clean
with a dry cloth.
Continuing to use the device in this condition
may result in fire.
When using this device, do not cover it, or wrap it
with anything.
Otherwise overheating may result in fire.
Do not use this device near a radio or a TV set.
The device may generate noise in a radio or TV
set.
When lifting the device up, do not hold handles of
power supply units or fan units in order to avoid
the handles taken off.
Avoid looking at the light source (e.g. laser light)
directly.
Failure to follow this may injure your eyes.
Caution
XG2600 Hardware Guide
13
Notes on Maintenance
•
Customers should not repair this device. In the event of failure, consult with a Fujitsu service engineer or an engineer
certified by Fujitsu for maintenance.
•
Do not dismantle or modify this device for any reason. This device contains high voltage and high temperature parts
that can be dagerous.
Precautions for Use
•
As a guideline, the expected life of the device is approximately five years, assuming use at an ambient temperature of
25°C.
•
Use of this hardware guide, the device, its firmware, and the management software are the responsibility of the user
and is undertaken at their own risk.
•
Fujitsu and its partners accept no responsibility for any errors or data loss arising from use of the product. Before using
the product, it should be understood that the device is not guaranteed against failure for any more than the original
purchase price.
•
Fujitsu and its partners do not approve of any use of the firmware provided with the device, or of any authorized
firmware upgrades, for any purpose other than installation in the intended device. Modification and disassembly are
not permitted under any circumstances. Use of the device or upgrading the device firmware implies acceptance of the
End User License Agreement stipulated within the User’s Guide.
Eliminating Static Electricity from Twisted Pair Cables (Grounding)
Under certain conditions, twisted pair cables can become charged with static electricity. Connecting a statically charged
twisted pair cable to the XG2600 can cause the device or its LAN port to operate falsely or to become damaged.
Use a static removal tool to discharge twisted pair cables to ground prior to connecting them to the XG2600.
Note that a discharged twisted pair cable that has been left unconnected for a long time may become statically charged
again.
Ensuring Security
If no password is set, any users on the network can configure this device. In that situation, you cannot ensure security
against unauthorized use. Therefore we strongly recommend that you set a password.
Cleaning
If cleaning the device while in service, use a damp soft cloth. Only use water or a mild detergent to dampen the cloth.
Avoid moisture entering vents or crevices in the chassis of the device.
Reference "2.3.1 Discharging Twisted Pair Cable" (pg.44)
Reference User’s Guide "5.14 Password Information" (pg.257)
XG2600 Hardware Guide
14
Electromagnetic Compatibility (USA)
FCC Part-15 Class A
Electromagnetic Compatibility (CANADA)
Industry Canada Interference-Causing Equipment Standard ICES-003 Class A.
This Class A digital appartatus complies with Canadian ICES-003.
Cet appareil numerique de la classe A est conforme a la norme NMB-003 du Canada.
Electromagnetic Compatibility (EU)
EN55022(2006) Class A
EN61000-3-2(2000)
EN61000-3-3(1995)+A1(2001)
EN55024(1998) + A1(2001) + A2(2003)
Safety
CAN/CSA C22.2 No. 60950-1, UL60950-1 and EN60950-1
High safety
High Safety Required Applications
The XG2600 is designed, developed and manufactured for general use, including, without limitation, general office use,
personal use, household use, and ordinary industrial use, but is not designed, developed and manufactured for use in
situations wherein failure of the XG2600 may result in death, personal injury, severe physical damage or other loss (herein
after referred to as "High Safety Required"), including, without limitation, nuclear reaction control systems in a nuclear
facility, aircraft flight control systems, air traffic control systems, mass transport control systems, medical life support
systems, and missile launch control weapons systems.
Do not use the XG2600 for High Safety Required applications without otherwise ensuring the safety level required. Fujitsu
and its related companies assume no liability whatsoever for damages arising from use of the XG2600 by the user in High
Safety Required applications, and for any claims or compensation for damages by the user or a third party.
FCC WARNING:
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This product meets the Class A requirements of EN55022. In a domestic environment this
product may cause raido interference in which case the user may be required to take
adequate measures.
Warning
Warning
XG2600 Hardware Guide
15
Laser Safety
The XG2600 may be installed with optical transceiver modules (SFP+ modules), which emit invisible laser light.
In the USA, these optical modules are certified as Class 1 laser products that conform to the requirements of the
Department of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. This certification is indicated by a
label attached to each optical module.
Outside the USA, these SFP+ modules are certified as Class 1 laser products that conform to the requirements of
EN60825-1 (2007).
Even when cables are not connected, invisible laser light may still be emitted from the optical module’s port openings. To
avoid possible injury, do not look directly into the optical module’s port openings.
Optical transceiver modules intended for use in the XG2600 must be selected from the Optical Transceiver Approved
Vendor List (obtainable from the vendor’s service department).
Notes on Rack Mounting and Connecting a Powerstrip
•
Monitor and control the internal and external temperature and humidity of the rack, so that it does not exceed the range
of guaranteed operation temperature and humidity.
•
The air intake and exhaust of the device is conducted at the port side and FAN unit side. Do not block the intake side or
exhaust side in order not to prevent airflow when installing.
•
Make sure to check the maximum loading capacity of the rack to be used for mounting.
•
Check the power supply capability of the installation location.
•
When connecting the power cable of the device to a powerstrip within a rack, a large amount of current leakage may
occur through the ground line of the powerstrip. Assure a good ground connection exists before connecting power to
the device. Assure power sourcing and leakage current carrying capabilities for the power strip are not exceeded. The
maximum current leakage for the device is 3.5 mA.
About Fujitsu's Green Products
"Green Products" that have passed Fujitsu's strict environmental assessment standards are earth-friendly and environment-
conscious products.
•
Main Features
-
Small size/resource saving
-
High rate of recycling
This symbol is attached to the Green Products that passed the Green Product Assessment Standard of Fujitsu.
For Fujitsu's environment protection efforts, refer to the following Fujitsu Web site.
URL : http://www.fujitsu.com/global/about/environment/ "Environment Protection Efforts"
If mounting this device in a rack, assure device operational temperature specification compliance,
mechanical stability of the rack, and proper electrical grounding of the device. This device must only
be mounted in a rack by a qualified engineer with the required training and knowledge. Failure to do
so may result in property damage, electric shock, or fire.
Warning
XG2600 Hardware Guide
16
Notes on Use
Before using this device, please read the following.
•
Customers are required to store and maintain configuration information for the device, after the configuration is
complete.
The configuration information can be used by Fujitsu or Fujitsu’s certified support engineer to restore configurations in
case of failure.
Unless the configuration information is available, it may cause difficulties and delays for the support engineer to
restore the device, Please backup the configuration information on a timely manner and always maintain it up to date.
•
This device contains a protection circuit against lightning and electrostatic discharge. Therefore, some of the functions
may not work when lightning or static electricity enters the device.
In such case, the device can be restored to its normal condition by power cycling the device. If the functions are still
not available after power-on, or if the power itself cannot be turned on, the device may have been destroyed due to
lightning or electrostatic discharge beyond the threshold of the protection circuit. In this case, contact Fujitsu or
Fujitsu’s certified support engineer for further instruction.
•
Do not turn the power off or reset the system during a firmware update, or the device cannot be enabled.
•
A User’s Guide for this product is provided on the accompanied CD-ROM in PDF format. Adobe Reader is required
for viewing the manual.
This chapter lists the items that should be in the product package, and describes the names and functions of the various
components.
1.1
Items in the Package, Descriptions and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.1.1
Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.1.2
Installation of Switch: Front Access or Rear Access (User Configured Airflow) . . . . . . . . 19
1.1.3
Switch Fan Unit Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
1.1.4
Switch Port Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.1.5
Top Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.1.6
BOTTOM Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1.2
Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.2.1
SFP+ Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
18
1.1
Items in the Package, Descriptions and
Functions
Before proceeding, check all the items described below.
1.1.1
Parts List
Please check that all of the following parts are included in the package.
•
XG2600
The XG2600 switch.
•
Power Cables (Qty 2)
Cables to connect the XG2600 to an AC power source.
•
SFP+ Dummy Caps (Qty 26)
Dummy caps to prevent dust when the SFP+ slots are open and unplugged.
The dummy caps come with the switch, installed on the slots at the time of purchase.
•
Console cable adapter (RJ45 to Serial Adapter)
Straight cable with RJ-45 to D-SUB9 Converter Adapter.
•
M6 Countersunk Screws (Qty 4)
Screws for fastening the rack rails to the front side of the rack.
•
M6 Machine Screws (Qty 6) 4 screws for fastening the rack rails to the rear side of the rack, and 2 screws for
fastening the switch (rack mounting brackets attached to the side of the switch) to the
front side of the rack).
•
Rack Mounting Rails (1 set)
Rails for mounting the switch in a rack.
XG2600 Hardware Guide
(with Licence Agreement)
M6 Countersunk Screws
(Qty 4)
XG2600
CD-ROM
SFP+ Dummy Caps
(Qty 26)
M6 Machine Screws
(Qty 6)
Power Cables (Qty 2)
Rack Mounting Rails (1 set)
XG2600
Console cable adapter
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
19
•
CD-ROM
It contains the Firmware and User Guide (in a PDF format) necessary for operating and
configuring the switch. Adobe Reader is required for viewing.
•
XG2600 Hardware Guide (with Licence Agreement)
This manual describes the hardware of the XG2600.
1.1.2
Installation of Switch: Front Access or Rear Access (User
Configured Airflow)
There are two options available to install the switch in a different direction in a rack that helps suppress heat interference,
depending on user’s requirements
•
Rear-Access Configuration (Factory Default)
The port side (SFP+ slots) is facing backward in a rack, which serves better for connecting the switch to equipment
whose port side is also located in the backside of the rack such as servers.
•
Front-Access Configuration (User Configured)
The port side (SFP+ slots) is facing forward in a rack, which serves better for connecting the switch to equipment
whose port side is facing forward such as other switches, routers, etc.
Choose either of the above to install the switch in the rack, depending on user’s requirements.
Note
• RS232C Cable is not included in the product package
• USB memory is not included in the product package
Reference
See "2.2.1 Decide Switch Access Configuration" (pg.31) for the detailed instructions for installation.
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
20
1.1.3
Switch Fan Unit Side
•
MAC Firmware Label
This indicates the MAC addresses and firmware revision assigned to the switch.
•
Fan Unit
This switch is installed with two Fan Units.
•
PSU Slots for Front-Access Configuration
Power Supply Units are plugged in the slots when the switch is used in a Front-Access
configuration.
•
model name, serial number label
This indicates the model name, and serial number.
LED Details
•
READY LED
Indicates the operational state of the switch.
•
CHECK LED
Lights in orange when there is a problem. In that case, consult with responsible
engineers immediately.
•
STATUS LED
Lights to show the status of the Fan Unit.
•
OUTFLOW LED
Lights to show the direction of fan (airflow).
XG2600
Fan Unit
FAN2
FAN1
PSU Slots for
Front-Access Configuration
PSU2
PSU1
MAC Firmware Label
model name,
serial number label
XG2600
READY
CHECK
STATUS
OUTFLOW
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
21
LED Functions/Behaviors
*) During the system diagnosis, READY LED is blinking in Green in every 0.5 second.
When the switch is operating under backup firmware, READY LED is blinking in Green in every 1 second.
LED Name
State
Status
READY
Green
Switch has started up correctly.
Green Blinking
Switch is being diagnosed or operating under backup firmware. (*)
Off
A problem has occurred.
CHECK
Orange
A problem occurs which may require switch replacement.
Orange Blinking
Firmware in the internal flash memory of the switch is destroyed.
Off
Switch is in normal operation.
STATUS
Green
Fan Unit is in normal operation.
Green Blinking
A problem has occurred with the Fan Unit.
Off
Fan Units are configured incorrectly or the power is not on.
OUTFLOW
Green
This indicates the FAN unit side is the exhaust side.
Off
This indicates the FAN unit side is the intake side.
Reference
See "2.2.1 Decide Switch Access Configuration" (pg.31) for detailed LED functions/behaviors under normal
operation.
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
22
1.1.4
Switch Port Side
•
PSU Slots for Rear-Access Installation
PSUs are plugged in the slots when the switch is used in Rear-Access configuration.
•
Power Inlet
Plug the attached Power Cable in the package.
•
Power Supply Unit
This switch is installed with two PSUs.
•
SFP+ Slots
Plug SFP+ modules for connecting Ethernet based networking equipment (10GBASE-
SR/10GBASE-LR).
Port number is assigned from the upper side of the leftmost port to the right. For
example, Port 1 is the upper side of the leftmost port, and Port 26 is the lower side of the
right most port.
•
Reset Switch
Press to reboot.
•
USB Port
Insert a USB memory device to load/save configuration files or update firmware.
•
Serial Port (Console Connection)
The Serial Port is used to connect the switch with the console (PC) for setting and
command line interface via the attached console cable adapter (RJ45 to Serial Adapter)
and RS232C crossover cable (D-SUB9).
Caution
Serial Port is only used for connecting the switch with RS-232C interface of the console. Do not
connect other interfaces such as LAN/ISDN which cause an error.
•
Management Port
This is used to connect Ethernet based (10/100BASE-TX) networking equipment. Use
Category-5 LAN cables.
The Management Port is MDI fixed. If you connect the device that have MDI fixed port
to the Management Port, please use the Crossover Cable.
Reference
User’s Guide "1.1.5 Console Port Specifications" (pg.29)
SFP+ Slots
Serial Port
PSU1
Power Supply Unit
Power Inlet
Management Port
USB Port
Reset Switch
PSU Slots for
Rear-Access Installation
PSU2
Power Supply Unit
Port1
Port2
Port26
Port25
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
23
LED Details
•
POWER LED
Lights to indicate the status of PSU.
•
SFP+ LINK/ACT LED
Lights to indicate the establishment of the link and status of the signal transmission.
•
SFP+ LED
Lights to indicate the status of optical detection of the SFP+ slot.
•
READY LED
Indicates the operational state of the switch.
•
CHECK LED
Lights in orange when there is a problem. In this case, consult with responsible
engineers.
•
PSU1 LED
Lights to indicate the status of the PSU1.
•
PSU2 LED
Lights to indicate the status of the PSU2.
•
FAN LED
Lights to indicate the status of the Fan.
•
FLASH LED
Lights to indicate the status of read/write of the external USB memory or internal.
Precautions
Do not shut down or reboot when FLASH LED is blinking in green. That may cause to destroy configuration files.
•
ERROR LED
There’s a problem with USB memory or SFP+ modules, or mount/access error.
•
LINK/ACT LED
Lights to indicate the status of the link, signal transmission, transmission speed.
•
FDX LED
Lights to indicate the status of transmission mode for the management port.
LINK/
ACT
FDX
Port1
Port2
Port1 SFP+
Port2 SFP+
Port2 SFP+
LINK/ACT
Port1 SFP+
LINK/ACT
READY
CHECK
PSU1
FLASH
ERROR
PSU2
FAN
POWER
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
24
LED Functions/Behaviors
*) During the system diagnosis, READY LED is blinking in Green in every 0.5 second.
When the switch is operating under backup firmware, READY LED is blinking in Green in every 1 second.
LED Name
State
Status
POWER
Green
PSU is in normal operation.
Orange
A problem has occurred with the PSU.
SFP+ LINK/ACT
Green
SFP+ link is established.
Green Blinking
SFP+ is in communication.
Off
SFP+ link is not established.
SFP+
Green
This indicates light detection of the SFP+ slot.
Off
This indicates light undetected of the SFP+ slot.
READY
Green
Switch has started up correctly.
Green Blinking
Switch is being diagnosed or operating under backup firmware. (*)
Off
A problem occurs.
CHECK
Orange
A problem occurs which may require switch replacement.
Orange Blinking
Firmware in the Flash memory of the switch is out of order.
Off
Switch is operating normally.
PSU1
Green
PSU1 is in normal operation.
Green Blinking
PSU1 is not installed or PSU1 is installed incorrectly, causing configuration error.
Off
A problem has occurred with PSU1, or the power is not on.
PSU2
Green
PSU2 is in normal operation.
Green Blinking
PSU2 is not installed or PSU2 is installed incorrectly, causing configuration error.
Off
A problem has occurred with PSU2, or the power is not on.
FAN
Green
2 Fan Units are in normal operation.
Green Blinking
Fan is not installed or Fan is installed incorrectly, causing configuration error.
Off
2 Fan Units are in normal operation.
FLASH
Green
USB memory is installed.
Green Blinking
External USB memory or internal flash memory are under read/write.
Off
USB memory is not installed, or internal flash memory are not under read/write
status.
ERROR
Orange
There’s a problem with USB memory or SFP+ modules, or mount/access error.
Off
USB memory and SFP+ modules are in normal operation.
LINK/ACT
Green
A link is established for the management port.
Green Blinking
Management port is in communication.
Off
A link is not established for the management port.
FDX
Green
Transmission mode for the management port is duplex.
Off
Transmission mode for the management port is half-duplex.
Reference
See "2.2.1 Decide Switch Access Configuration" (pg.31) for detailed LED functions/behaviors under normal opera-
tion.
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
25
1.1.5
Top Surface
•
Warning Sticker
This indicates the warning for safety use.
•
Rating Label
This indicates the rated voltage of the switch.
Warning Sticker
Rating Label
XG2600 Hardware Guide
Chapter 1 Getting Started
Items in the Package, Descriptions and Functions
26
1.1.6
BOTTOM Surface
•
Product Manufacturing Label
This indicates the model name, serial number, manufacturing date, and Class 1 Laser
Product, etc.
Product Manufacturing Label
XG2600 Hardware Guide
Chapter 1 Getting Started
Option
27
1.2
Option
1.2.1
SFP+ Modules
SFP+ modules (10GBASE-SR/10GBASE-LR) are available for use.
Reference
"2.3.3 Connecting Twisted Pair Cable / SFP+ Module" (pg.46)
User’s Guide " SFP+ Module" (pg.26)
This chapter describes how to install the switch and connect it to Console PC.
2.1
Requirements for Installation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.1.1
Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.1.2
Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.2
Installation of the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.2.1
Decide Switch Access Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.2.2
Rear-Access Configuration (Factory Default). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.2.3
Change Switch Access Configurations from Rear-Access (Factory Default) to Front-
Access and Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
2.3
Connecting the Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
2.3.1
Discharging Twisted Pair Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
2.3.2
Cleaning SFP+ Module / Optical Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
2.3.3
Connecting Twisted Pair Cable / SFP+ Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.3.4
Plugging in the USB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2.4
Connecting a Setup PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
2.5
Time Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
2.6
Set up IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
XG2600 Hardware Guide
Chapter 2 Installation
Requirements for Installation Environment
29
2.1
Requirements for Installation
Environment
Before installing the switch, please check the following:
•
Make sure that the switch and all the other options shown in this document are available for installation.
•
All the cables comply with the specifications of the interface connectors.
Warning
Do not connect cables to interface connectors other than those adaptable to the connector’s
specifications.
Install the product under the following environmental conditions.
2.1.1
Installation Requirements
Caution
Install the product under the following conditions. Using the product outside the required
environment may cause failure of the product.
Temperature and Humidity Requirements
Power Requirements
Reference
"1.1.1 Parts List" (pg.18)
Temperature (degrees C)
Humidity (%RH)
Operation
0 to 40
15 to 85
Non-operation
0 to 50
8 to 90
Item
Requirements
Voltage
AC90V-264V
Frequency
50Hz / 60Hz +2%, -4%
Ground
Separate ground wire from air conditioners and building, and D-class grounding
with ground resistance of 100 Ω or less.
Electricity
AC input more than 128W
Inrush Current
Maximum 30A
Ensure installation environment that avoids lowering voltage to power supply
equipment at the time of power-on due to the inrush current, although there’s no
impact from the inrush current in normal use.
XG2600 Hardware Guide
Chapter 2 Installation
Requirements for Installation Environment
30
Installation Requirements
The product is specifically designed for rack-mounting.
Check-list
Check the following items.
2.1.2
Space Requirements
When installing the switch and providing maintenance, ensure the space below is maintained.
Ensuring the Space for Installation (Maintenance) of the Switch
Internal cooling fans of the switch allow the air intake and exhaust performed at both at the Port Side and Fan Unit Side.
Ensure the indicated space below and do not put anything which avoids airflow.
Check Item
Check Result
Nothing is put on the switch.
Vents are not obstructed.
The switch is not located on the table or not stuck on another switch.
The switch is not located under direct sunshine, near heating appliance, under high humidity
or in a dusty area..
The switch is not located on unstable places where vibrating, or tilting.
"About Warning Descriptions" has been thoroughly read
(pg.10)
Reference
Reference
rack
300mm or more
800mm
800mm
XG2600
90mm
or more
150mm
or more
Back space for
the maintenance
Space for the
maintenance/
installation
Space for the
maintenance/
installation
300mm or more
Front space for
the maintenance
19" rack Width
19" rack
Depth
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
31
2.2
Installation of the switch
This section describes how to install the switch.
2.2.1
Decide Switch Access Configuration
The switch is specifically designed for rack-mounting.
The switch can be installed in two different switch access configurations (airflow directions) in a rack.
•
Rear-Access Configuration (Factory Default)
•
Front-Access Configuration (User Configured)
The following describes how to install each airflow configuration.
Caution
Do not hold the handle of PSU and Fan Unit when picking up the switch. The handle may come
off and cause injury.
Rear-Access Configuration (Factory Default)
The port side (SFP+ slots) is facing backward in the rack.
XG2600
Intake
Exhaust
(Caution) (Caution)
PSU1
PSU2
FAN1
FAN2
Rack Rear
Rack Front
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
32
Caution
•
Do not install PSUs to face the front side of the rack. They do not work properly.
•
Before installing the switch in the rack, check if the airflow direction of the fans is correct. If the
air flows incorrectly, it may cause failure to the switch
The diagram below shows in which slots PSUs need to be installed and airflow direction of the fans.
: Installing – : not installing
The LED lights in a correct configuration as follows:
– : Unsupported because the unit is not installed
If the LED indicators are different from the above, it may be due to the incorrect configuration of PSUs and/or Fans, or
there may be failures with PSUs and/or Fans.
Power Supply Unit
Fan Unit
Switch Port Side
Switch Fan Unit Side
FAN1 Slot
FAN2 Slot
PSU1 Slot
PSU2 Slot
PSU1 Slot
PSU2 Slot
Installation
Airflow
Installation
Airflow
–
–
Intake
Intake
Switch Port Side
Power Supply Unit
Switch Fan Unit Side
Switch Port Side
Switch
Fan Unit Side
Slot 1/Slot 2
READY
CHECK
PSU1
PSU2
FAN
PSU1
PSU2
PSU1
PSU2
STATUS
OUTFLOW
POWER
Green
Off
Green
Green
Green
Green
Green
–
–
Green
Off
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
33
Front-Access Configuration (User Configured)
The port side (SFP+ slots) is facing forward in a rack.
Caution
•
Do not install PSUs facing the front side of the rack. They do not work properly
•
Before installing the switch in the rack, check if the airflow direction of the fans is correct. If the
air flows incorrectly, it may cause failure to the switch.
XG2600
Exhaust
Intake
(Caution)
PSU1
PSU2
FAN1
FAN2
Rack Rear
Rack Front
(Caution)
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
34
The diagram below shows in which slots PSUs need to be installed and airflow direction of the fans.
: Installing – : not installing
The LED lights in a correct configuration as follows:
– : Unsupported because the unit is not installed
If the LED indicators are different from the above, it may be due to the incorrect configuration of PSUs and/or Fans, or
there may be failures with PSUs and/or Fans.
If the switch is installed in Front-Access configuration, it is necessary to remove PSUs and install them in different slots
than factory default ones, and change direction of fans.
Power Supply Unit
Fan Unit
Switch Port Side
Switch Fan Unit Side
FAN1 Slot
FAN2 Slot
PSU1 Slot
PSU2 Slot
PSU1 Slot
PSU2 Slot
Installation
Airflow
Installation
Airflow
–
–
Exhaust
Exhaust
Switch Port Side
Power Supply Unit
Switch Fan Unit Side
Switch Port Side
Switch
Fan Unit Side
Slot 1/Slot 2
READY
CHECK
PSU1
PSU2
FAN
PSU1
PSU2
PSU1
PSU2
STATUS
OUTFLOW
POWER
Green
Off
Green
Green
Green
–
–
Green
Green
Green
Green
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
35
2.2.2
Rear-Access Configuration (Factory Default)
This section describes how to install switch in Rear-Access configuration (Factory Default).
Decide positions for rack mounting brackets
1.
Decide positions of rack mounting brackets.
It is possible to install the switch either in a standard front position of the rack or in an offset position of the rack.
In case to locate the switch offset from the front side, change the positions of rack mounting brackets.
[STANDARD]
Rack Mounting Brackets
[OFFSET]
XG2600
XG2600
Plug into the
hole of the device.
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
36
Install the switch in a 19” rack
The switch can be installed and operated in the EIA standard 19" rack.
Prepare the following rack mounting components attached.
•
Rack Mounting Rails (1 set): Rails for mounting the switch in a rack.
•
M6 Countersunk Screws (Qty 4)
•
M6 Machine Screws (Qty 6)
Precautions
•
Pay attention to control temperature inside and outside of the rack so that guaranteed operating temperature can be
maintained properly for the switch.
•
Reserve certain space for air cooling in accordance with the cooling structure of the switch.
•
Ensure physical stability of the whole rack when the switch is installed.
•
Check if power supply capacity (Rated Current) is sufficient from the power supply equipment such as power strip,
service outlet from other devices or rack.
•
High Touch Current may flow through power strip earthing conductor, if power supply cord of this unit is connected
to power strip.
Earth connection essential before connecting supply.
If the power supply cord is not directly connected to branch circuit, Power Strip which has Industrial Type
Attachment Plug should be used.
Installation procedure is described below.
Be sure to keep sufficient front and rear space for safe installation service.
1.
Fix rack mounting rails to the rack posts.
Loosen four M4 screws which are originally fixed to rails, adjust length of the screws, and fix the rails to the rack.
Once the rails are fixed to the rack, fasten again the four M4 screws.
Reference
"1.1.1 Parts List" (pg.18)
M4 Machine Screws
M6 Countersunk Screws
M6
Machine Screws
M6 Countersunk Screws
M6
Machine Screws
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
37
2.
Slide the switch between rails which are fixed to the rack, and fasten the 2 M6 screws to the front
posts.
Precautions
Pre-occupied devices in the upper and/or lower row of the rack may interfere with the power cable of the switch from
being properly installed. In that case, plug the power cable to the switch before install it in the rack.
M6 Machine Screws
M6 Machine Screws
XG2600
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
38
2.2.3
Change Switch Access Configurations from Rear-Access
(Factory Default) to Front-Access and Install
This section describes how to change Rear-Access configuration (Factory Default) to Front-Access.
Remove rack mounting brackets
1.
Remove rack mounting brackets attached to the sides of the switch.
Change the direction of fans to adjust airflow
Change the direction of fans, depending on which switch access configuration to go with, Rear-Access or Front-Access.
Check the direction of fans before installing the switch in the rack.
Airflow is as shown below.
•
Rear-Access Configuration (Factory Default)
•
Front-Access Configuration
Note
For Front-Access configuration to Rear-Access, make the procedure reversed.
Rack Mounting Brackets
XG2600
Intake
Airflow Label
Exhaust
Exhaust
Airflow Label
Intake
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
39
1.
Loosen two screws to remove fan unit.
2.
Remove fans
(1) Remove two screws.
(2) Unlock Cable Holder (which prevents cables from being pulled out).
(3) Remove cables
3.
Change direction of fans.
(1) Turn over the fan.
Screw
Screw
XG2600
(1)
(2)
(3)
(1)
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
40
(2) Check if the direction shown in Airflow Label matches the airflow direction required.
(3) Unlock Cable Holder to which the cable is connected.
(4) Lock the unused Cable Holders.
4.
Fix fans.
(1) Fasten screws.
(2) Connect cables.
(3) Lock Cable Holder for the connected cables to prevent the cable from being accidently pulled out.
5.
Insert back the Fan unit in the fan slot and fasten two screws to fix it to the switch.
(4)
(3)
(2)
(1)
(2)
(3)
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
41
Change PSU’s positions to meet different switch access configurations
There are two types of PSU Slot Bezel.
•
PSU Bezel (Vents with Logo)
Put it to empty PSU1 slot.
•
PSU Bezel (Vents without Logo)
Put it to empty PSU2 slot right next to PSU1 slot.
The procedure to change PSU configurations is shown below.
1.
Remove screws to take off two PSU slot bezels on the Fan Unit side (PSU1 and PSU2 slots).
2.
Remove screws and take off PSU units on the Port Side.
Vents with Logo
Vents without Logo
XG2600
SR-X526R1
Screw
XG2600
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
42
3.
Put PSU Bezel (Vents with Logo) to PSU1-slot on the Port Side with screws. Put PSU Bezel (Vents
without Logo) to PSU2-slot right next to PSU1 slot with screws.
4.
Slide PSUs into PSU1-slot and PSU2-slot and fix them to the switch with screws.
XG2600
SR-X526R1
XG2600 Hardware Guide
Chapter 2 Installation
Installation of the switch
43
Attach rack mounting brackets to the switch
1.
Attach rack mounting brackets to fit either a standard front position of the rack or a offset position of
the rack.
Precautions
PSUs have to always be located in the rear side of the rack. If the position of PSUs is not appropriate, rack mounting
brackets cannot be attached to the switch properly. Check the PSU configuration.
Install the switch in a 19" rack
The switch can be installed and operated in the EIA standard 19" rack.
Reference
" Install the switch in a 19” rack" (pg.36)
[STANDARD]
[OFFSET]
Rack Mounting Brackets
XG2600
XG2600
Plug into the hole
of the device.
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
44
2.3
Connecting the Equipment
We recommend discharging static electricity of twisted pair cable before connecting it to the switch.
Also see below for how to install USB memory.
2.3.1
Discharging Twisted Pair Cable
Discharge static electricity of the twisted pair cable through the ground wire cable (ground wire for power supply,
buildings, etc.) using static electricity removal tool, before connecting twisted pair cable to the switch.
Precautions
•
Unplug both ends of the twisted pair cable from equipments (HUB, router, and workstation) during discharging
operation.
•
Do not use ground wire of electronic devices. Use grounded cable for power supply or buildings.
•
Do not short circuit with AC power supply when using ground wire for power suppl.
2.3.2
Cleaning SFP+ Module / Optical Connector
When invisible small dust is adhered to SFP+ module /optical connector, optical signal will be shut or space caused by dust will
impede transmission of optical signal.
Therefore, clean up SFP+ module /optical connector before connection.
Cleaning of SFP+ Module
1.
Blow dust away with cleanly dry air or nitrogen.
Check end face, and conduct operation below if dust is left.
2.
Lightly dampen a cleaning stick (1.25mm across, for LC/MU) with isopropyl alcohol. After wiping off
dust, slowly and carefully wipe off alcohol with a new and dry cleaning stick.
3.
Insert a cleaning stick to the optical connector insertion part of SFP+ module, and slowly wheel it.
4.
Insert and slowly wheel a new cleaning stick, and dry the SFP+ module.
5.
Check if the dust is removed with 200-fold magnification fiber scope.
SFP+ module
cleaning stick
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
45
Cleaning of Optical Connector
1.
Remove the connector guard cap of optical fiber part, and check the connector end face.
If the end face is not clean, clean it with a reel type fiber cleaner.
2.
Push thumb holder of a fiber cleaner and open a cap of the fiber cleaner.
3.
When a cap slides and a new cleaning tape comes out, lightly apply the end face to a cleaning tape.
4.
Apply the end face of the connector and rotate it (quarter turn four times).
5.
Apply the end face to the cleaning tape, and move it to forward direction of a fiber cleaner.
Caution
Do not friction the end face to the cleaning tape. It will cause micro dust or scratch.
6.
Take thumb holder off, and close a cap of a fiber cleaner.
7.
Check the end face and continue cleaning if necessary.
Removal of Micro Dust
Remove micro dust on the optical fiber part following the method below if necessary.
1.
Wipe the optical fiber part with ethanol or cleaning fluid.
2.
Softly and slowly wipe the optical fiber part with cleaning fabric.
3.
Wipe with a new cleaning stick in the same fashion, and dry the optical connector.
Caution
•
Do not use fluid such as bleach because it will damage optical coupling.
•
Use ionizer when cleaning in order to avoid the ESD damage to SFP+ module.
•
SFP+ module cannot be washed with water. Do not use or clean SFP+ module in a wet space such
as bathroom or kitchen.
•
Carefully treat SFP+ module as it sometimes becomes very hot.
Precautions
•
Do not use alcohol, spray, and cotton swab for cleaning of optical connector other than special optical connector
cleaner because dust on the end face of the optical connector plug may not be completely wiped off and more dust
may adhere.
•
Immediately connect optical connector to the switch after cleaning. Dust will adhere when the optical connector is
left unconnected.
•
Keep the connector guard cap fixed before using SFP+ module in order to avoid contamination.
•
When SFP+ module is contaminated, check end face and clean only if necessary.
•
If a lot of fluid is used, it will possibly be accumulated or leak out because SFP+ module is not hermetically closed.
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
46
2.3.3
Connecting Twisted Pair Cable / SFP+ Module
Below is how to connect twisted pair cable and SFP+ module.
Use the crossover cable when connecting with routers and terminals. Use the straight cable in case of cascading
connection with other switching HUBs with transmission mode at fixed setting other than auto negotiation.
Management port of the switch is set auto negotiation enable by default.
(However, SFP+ slots only support 10Gbps full duplex mode fixed setting.)
Ports automatically apply to the maximum speed that plugged equipment supports by the auto negotiation function.
•
100BASE-TX port
: Up to maximum 100Mbps full duplex mode
The Management Port is MDI fixed. If you connect the device that have MDI
fixed port to the Management Port, please use the Crossover Cable.
Connecting Twisted Pair Cable
Insert twisted pair cable to 10/100BASE-TX port until it clicks.
Precautions
•
Usable twisted pair cables are unshielded twisted pair cable (UTP) over category 5E and shielded twisted pair cable
(STP).
•
Discharge twisted pair cable before connecting as twisted pair cable may be charged static electricity. Refer "2.3.1
Discharging Twisted Pair Cable" (pg.44) for discharging method.
straight cable
crossover cable
optical cable
Twisted Pair Cable
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
47
Connecting SFP+ Module
Firmly install SFP+ module to SFP+ slot and lock module to the switch.
Precautions
•
Safely keep a guard cap of SFP+ module.
•
Make sure to clean the end face of SFP+ module / optical cable before connecting optical connector because the
end face may possibly be contaminated.
•
Do not directly touch the contact part of SFP+ module by hands. Use wristbands when touching SFP+ module.
•
Connecting part to the optical cable of SFP+ module is the laser opening.
There are two types of SFP+ modules, veil latch type and standard latch type.
Below is how to connect.
•
Veil Latch Type
Insert SFP+ module to the SFP+ slot with a lever locked, and lock the module and the switch.
Connect optical cable (connector shape: DLC) after inserting SFP+ module to the SFP+ slot.
When removing SFP+ module, unlock the lever, module and the switch, and remove the module after unplug the
optical fiber.
•
Standard Latch Type
Insert SFP+ module to the SFP+ slot, and lock the module and the switch.
Connect optical cable (connector shape: DLC) after inserting SFP+ module to the SFP+ slot.
When removing SFP+ module, remove the module after pressing a tab to unlock the module and the switch.
SFP+ module
Lever
Tab
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
48
Precautions
Cable length will be as below based on the specification of the optical fiber cable.
Use the appropriate cable according to the installation place.
Replacing SFP+ Module
Precautions
It is possible to install/replace SFP+ module with the power on.
When replacing SFP+ module, follow the process below.
1.
Make the replacing SFP+ slot to the "disable status".
•
In case of using telnet or console
Enter replacing SFP+ slot number in
•
In case of using www browser
Make the SFP+ slot number to the selective status by "Setting of physical port" of settings menu.
Select "Disuse" of "Use of Physical Port", and click "Regist" icon.
2.
Replace the SFP+ module after removing optical cable, and then install the SFP+ module.
Type
Core/Cladding Diameter
Minimum Transimission Band
Cable Length (m)
MMF
62.5/125µm
160MHz/km
26
200MHz/km
33
50/125µm
400MHz/km
66
500MHz/km
82
2000MHz/km
300
# offline ether
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
49
3.
Connect optical cable and release the “disable status” of the SFP+ slot.
•
In case of using telnet or console
Enter replacing SFP+ slot number in
•
In case of using www browser
Make the SFP+ slot number at the selective state by "Setting of physical port" of settings menu.
Select "Use" of "Use of physical port", and click "Regist" icon.
4.
In case ERROR LED was blinking before replacement, confirm that ERROR LED is off after
replacement.
# online ether
Reference
User’s Guide "5.43.1.1 offline" (pg.532), "5.43.1.2 online" (pg.533)
XG2600 Hardware Guide
Chapter 2 Installation
Connecting the Equipment
50
2.3.4
Plugging in the USB Memory
USB memory can be plugged in from the port side of the switch.
Caution
Do NOT unplug out the memory stick during access. It may result in crashing setting data.
Precautions
It is possible to plug/unplug SFP+ module with the power on.
Plug in the USB Memory
Please refer to the following instructions;
1.
Firmly insert the USB memory to USB port on the port side of the switch.
Replacing the USB Memory (Unplug)
Please refer to the follow instructions;
1.
Make the USB port to "disable status" using the console command.
2.
Check and confirm that USB port is in a "disable status".
Execute command "show usb hcd status", and check and confirm that the status is displayed as "disable".
3.
Unplug the USB memory from the switch.
4.
Plug in the replacing USB memory onto the switch.
5.
Release the "disable status" of the USB port using the console command.
# usbctl disable
# show usb hcd status
[USB HCD STATUS]
status
: disable
Note
The process ends here, when you are only detaching the USB memory from the switch.
# usbctl enable
USB Memory
XG2600 Hardware Guide
Chapter 2 Installation
Connecting a Setup PC
51
2.4
Connecting a Setup PC
This is to connect a set up PC to the console port of the switch using RS232C cable.
Necessary Hardware / Software
Please prepare the hardware & software specified below to connect to the switch.
•
Personal Computer
1 unit of personal computer for setting up configuration is required.
•
RS232C crossover (null modem), D-SUB9F to D-SUB9F cable
A RS232C cable is required to connect the set up PC to the switch.
A RS232C crossover cable is not provided with the switch.
The console cable adapter which is included in this product is used with the RS232 cable to connect the set up PC to
the switch.
•
Communication Software
Terminal emulation software is required.
Connect RS232C Cable
1.
Confirm power of both the PC and the switch are off.
2.
Connect the RS232C cable and the console cable adapter which is included in this product, and
firmly fix them with the screw.
3.
Plug in the RJ45 plug of the console cable adapter to the console port of the switch.
Reference
User’s Guide "1.1.5 Console Port Specifications" (pg.29)
XG2600 Hardware Guide
Chapter 2 Installation
Connecting a Setup PC
52
Turn on the Power
Caution
•
Please use the power cable included in this product. Also, please do NOT use this power cable
on other products.
•
If the power outlet does not match with the power cable plug, please use the change plug
adapter.
As a safety measure to prevent electrical shocks, please make sure to connect the ground wire
of the change plug.
Precautions
•
Please set the switch (product) to a place near the electrical outlet which the power cable will be connected and
secure a space for the power cable to be pulled off easily.
•
Please connect the power cable in the following order. PSU1→ PSU2
If you connect the cable in the wrong order, the CHECK LED will lit in orange. If the CHECK LED is lit, delete the
error log using the console command after turning on the power of the switch.
•
When turning off the power. Please follow the above steps in an opposite order.
1.
Connect the power cable to the electrical outlet.
2.
Plug in the power cable to the power connecter of PSU1.
Power will turn on.
# clear logging error
#
Reference
User’s Guide "5.18.1.5 clear logging error" (pg.365)
XG2600 Hardware Guide
Chapter 2 Installation
Connecting a Setup PC
53
3.
POWER LED of PSU1 and PSU1 LED of the switch will light in green.
Next, plug in the power cable to the power connecter of PSU2.
The POWER LED of PSU2 and PSU2 LED of the switch will light in green.
Prepare a Setup PC
Log on using the terminal software.
1.
Start up the terminal software by using the set up PC.
2.
Set the setting conditions to the following;
Please refer to the terminal software manual for instructions on setting conditions.
3.
Press [Return] key or [Enter] key.
Precautions
The following message may appear When pressing the [Return] key or [Enter] key. In such case, the switch is
processing another job, and waiting for such process to finish. Please wait for a moment until it finishes such process.
Waiting for completion of the other operation...
4.
Confirm "Login :" on screen.
5.
Key in "admin" and press [Return] key or [Enter] key.
6.
Confirm "Password:" on screen
7.
Key in password, then press the [Return] key or [Enter] key.
Since password is not set at the initial state, simply press [Return] key or [Enter] key without keying in the password.
If the password is already set, key in the password. Then press [Return] key or [Enter] key.
Setup
Items
Start Bit
1
Data Bit
8
Parity Bit
n/a
Stop Bit
1
Synchronous System
Asynchronous Communication System (Start-Stop Communication System)
Communication Speed
9600
Flow Control
None
Number of digits on screen
80 (If other than 80 digits, set it through terminal command)
Number of rows on screen
24 (If other than 24 rows, set it through terminal command)
PSU1
POWER
PSU2
XG2600 Hardware Guide
Chapter 2 Installation
Connecting a Setup PC
54
8.
Confirm “#” is shown on screen.
If the key in the wrong password, "invalid password." will be displayed, then the "Login :" will be displayed again. Please
repeat your process from item 5.
XG2600 Hardware Guide
Chapter 2 Installation
Time Setting
55
2.5
Time Setting
Make sure to set up the time before you do other settings of the switch. The time is not set at the initial timing of purchase.
Please refer below command for setting up time manually using console or telnet.
z Command
When setting time and date to be "Jan 1, 2011 12:30:00am" type in command
# date 2011/01/01.12:30:00
XG2600# configure
Switch to Configuration mode.
XG2600(config)# time zone -0500
When setting time zone to be “-0500”.
XG2600(config)# commit
Apply the configuration.
XG2600(config)# save
Save the configuration.
XG2600(config)# exit
Switch to Operation mode.
XG2600# date 2011/01/01.12:30:00
Set time and date to be “Jan 1, 2011 12:30:00am”.
XG2600 Hardware Guide
Chapter 2 Installation
Set up IP address
56
2.6
Set up IP address
Please set the IP address at times when it is required.
Eg. When setting the switch through www browser or installing a firmware from the initial state of the purchase.
The following commands show how to set up the IP address (ex. 192.168.1.1)
z Command (When connecting through management port)
z Command (When connecting through10GBASE-R (SFP+) port)
Precautions
•
The IP address is not set at the initial state of the purchase. Please set the IP address through console.
•
When logging in by console, you will not be able to log in from the www browser. Please make sure to log off from
the console after setting up the IP address.
•
Please set up different network address when setting “oob ip address” command and “lan ip” address command at
the same time.
XG2600# configure
XG2600(config)# oob ip address 192.168.1.1/24 3
XG2600(config)# commit
XG2600(config)# exit
XG2600#
XG2600# configure
XG2600(config)# lan 0 ip address 192.168.1.1/24 3
XG2600(config)# lan 0 vlan 1
XG2600(config)# commit
XG2600(config)# exit
XG2600#
XG2600 Hardware Guide
Index
57
Index
B
BOTTOM Surface .................................................... 26
C
CD-ROM .................................................................. 19
CHECK LED ..................................................... 20, 23
Communication Software ......................................... 51
Connecting the Equipment ....................................... 44
Console cable adapter .............................................. 18
Console port ............................................................. 51
E
ERROR LED ............................................................ 23
F
FAN LED ................................................................. 23
Fan Unit .................................................................... 20
FDX LED ................................................................. 23
FLASH LED ............................................................ 23
Front-Access Configuration ..................................... 33
H
Hardware .................................................................. 51
I
Install the switch in a 19" rack ................................. 36
Installation of the switch .......................................... 31
Installation Requirements ................................... 29, 30
Items in the Package ................................................. 18
L
LINK/ACT LED ...................................................... 23
M
M6 Countersunk Screws .......................................... 18
M6 Machine Screws ................................................. 18
MAC Firmware Label .............................................. 20
Management Port ..................................................... 22
model name, serial number label ............................. 20
O
Option ....................................................................... 27
organization of the manuals ....................................... 9
OUTFLOW LED ..................................................... 20
P
Power Cables ............................................................ 18
Power Inlet ............................................................... 22
POWER LED ........................................................... 23
Power Requirements ................................................ 29
Power Supply Unit ................................................... 22
Product Manufacturing Label .................................. 26
PSU Slots for Front-Access Configuration .............. 20
PSU Slots for Rear-Access Installation ................... 22
PSU1 LED ................................................................ 23
PSU2 LED ................................................................ 23
R
Rack mounting ......................................................... 43
Rack Mounting Rails ............................................... 18
Rating Label ............................................................. 25
READY LED ..................................................... 20, 23
Rear-Access Configuration ...................................... 31
Requirements for Installation Environment ............. 29
Reset Switch ............................................................. 22
RS232C cable ........................................................... 51
S
Serial Port (Console Connection) ............................ 22
SFP+ Dummy Caps .................................................. 18
SFP+ LED ................................................................ 23
SFP+ LINK/ACT LED ............................................ 23
SFP+ Module ........................................................... 27
SFP+ Slots ................................................................ 22
Software ................................................................... 51
Space Requirements ................................................. 30
STATUS LED .......................................................... 20
Switch Fan Unit Side ............................................... 20
Switch Port Side ....................................................... 22
T
Temperature and Humidity Requirements ............... 29
terminal software ...................................................... 53
Top Surface .............................................................. 25
Turn on the Power .................................................... 52
Twisted Pair Cable ................................................... 44
XG2600 Hardware Guide
Index
58
U
USB Memory ........................................................... 50
USB Port .................................................................. 22
W
Warning Sticker ....................................................... 25
XG2600 Hardware Guide
TA41001-7426
Issued on
February, 2011
Issued by
FUJITSU LIMITED
Printed in Japan
• The contents may be revised without prior notice.
• Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of
any information in this manual.
• No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
• Manuals with missing or wrongly collated pages will be replaced free of charge.
• EC declaration of conformity and the technical documentation are kept at the following
FUJITSU TECHNOLOGY SOLUTIONS (HOLDING) B.V.
Het Kwadrant 1, 3606 AZ Maarssen, The Netherlands
Highlight Towers, Mies-van-der-Rohe-Strasse 8, 80807 Munich, Germany