Quadra-Fire CB1200M-MBK Owner's Manual
Read Online
Read the Quadra-Fire CB1200M-MBK Owner's Manual online using the built-in PDF viewer.
Text of the manual
December 16, 2011
CLASSIC BAY 1200 PELLET STOVE
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Owner’s Manual
Installation and Operation
CB1200M-MBK
Model:
DO NOT DISCARD THIS MANUAL
NOTICE
• Important operating and
maintenance instruc-
tions included.
• Leave this manual with
party responsible for use
and operation.
• Read, understand and
follow these instruc-
tions for safe installa-
tion and operation.
DO NOT
DISCARD
WARNING
Please read this entire manual
before installation and use of this
pellet fuel-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• Do not overfire - If any external part starts to
glow, you are overfiring. Reduce feed rate.
Overfiring will void your warranty.
• Comply with all minimum clearances to com-
bustibles as specified. Failure to comply may
cause house fire.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national
codes and regulations.
• Consult local building, fire officials or authorities having jurisdic-
tion about restrictions, installation inspection, and permits.
CAUTION
Tested and approved for wood pellets and shelled
field corn fuel only. Burning of any other type of fuel
voids your warranty.
CAUTION
WARNING
Hot glass will cause burns.
•
Do not touch glass until it is cooled
•
NEVER allow children to touch glass
•
Keep children away
•
CAREFULLY SUPERVISE children in same room as
fireplace.
•
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
•
Keep clothing, furniture, draperies and other flammable
materials away.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
To obtain a French translation of this manual, please
contact your dealer or visit www.quadrafire.com
Pour obtenir une traduction française de ce manuel,
s’il vous plaît contacter votre revendeur ou visitez
www.quadrafire.com
NOTE
December 16, 2011
R
CB 1200 Pellet Stove
and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of
excellence! In choosing a Quadra-Fire appliance, you have
our assurance of commitment to quality, durability, and perfor-
mance.
This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we make
products that will satisfy your needs. Our Research and Devel-
opment facility then employs the world’s most advanced tech-
nology to achieve the optimum operation of our stoves, inserts
and fireplaces. And yet we are old-fashioned when it comes to
craftsmanship. Each unit is meticulously fabricated and surfaces
are hand-finished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality control
inspection from design, to fabrication, to shipping.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.
SAMPLE
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].
7014-079
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in China/Fait Aux Chine
1445 Highway North
Colville, WA 99114
www.quadrafire.com
A
Back Wall to stove / Mur Arrière du poêle
2"/51mm
B
Side Wall to Cast Top / Mur De Côté du haut
6"/152mm
CORNER INSTALLATION / NSTALLATION DU COIN :
C
Side Wall / Mur De Côté
2"/51mm
VERTICAL ADAPTER KIT INSTALLATION:
UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE:
D
Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76mm
B
Side Wall to Cast Top / Mur De Côté du haut
6"/152mm
CORNER INSTALLATION WITH VERTICAL ADAPTER KIT:
INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:
E
Side Wall / Mur De Côté
2"/51mm
ALCOVE INSTALLATION / INSTALLATION DE L' ALCÔVE:
Max. Alcove Depth: / La profondeur maximum de l'alcôve
36"/914mm
A
Back Wall to stove / Mur Arrière du poêle
2"/51mm
B
Side Wall to Cast Top / Mur De Côté du haut
6"/152mm
C
Unit corner to diagonal wall /
2" (51mm)
F
Top of Unit to Combustibles / Du poêle du haut combustibles 12.5"/318mm
Alcove vertical installation / Installation verticale de l'alcôve
D
Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76mm
Floor protector must be noncombustible material, extending beneath heater and to the
front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door.
G = 2"/51mm
H* = 2"/51mm
I = 6"/152mm
FLOOR PROTECTION / PROTECTION DU SOL
Note 1: In residential installations, when using Parts 811-0580, (3" - 3" Top Vent Adapter) and
812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used.
Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de
ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6"
pour mur simple de calibre 24 peut être utilisé.
Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and
812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector. An Outside Air Kit
(Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation.
Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de
l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), utilisez un
tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière
au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées.
*Non-combustible floor protection must extend beneath the flue pipe when installed with
horizontal venting or under the Top Vent Adapter with vertical installation.
RECOMMENDED IN USA; REQUIRED IN CANADA
Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les
schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée.
*Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une
installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une
installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT
D
B
C
C
E
E
A
B
H*
G
G
I
A
B
C
C
F
A
D
2010 2011 2012 JAN
FEB
MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has
been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E1509-95, ULC/ORD-C-1482-M1990, ULC S627-M93 Room Heating Pellet Burning Type,
APFI, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.
Input Rating: 40,000 Btu's/hr
Electrical Rating: 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm
ceramic available from your dealer. To start, set thermostat above room temperature, the stove will light
automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's
manual.Keep viewing and ash removal doors tightly closed during operation.
Testé à: ASTM E1509-95, ULC/ORD-C 1482-M1990, ULC S627-M93 Room Heating. Pellet Burning Type, APFI, (UM)
84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS.
Puissance de Rendement: 40,000 Btu's/hr
Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps,
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera
automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des
instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres
fermées hermétiquement durant l'opération.
Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet
appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
R
Report / Rapport
061-S-21-4
CB 1200 Pellet Stove
SERIAL NO. / NUMÉRO DU
CAUTION: HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions
products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.
ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE
CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne
pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
007C
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:
Behind left side curtain on outside of hopper wall.
Testing Lab &
Report Number
Serial Number
Model
Mfg Date
NOTE: Consult insurance carrier, local building inspector, fire officials
or authorities having jurisdiction over restrictions, installation inspection
and permits.
December 16, 2011
7014-179D
Page 3
CB 1200 Pellet Stove
Section 1: Listing and Code Approvals
A. Appliance Certifications.......................4
B. Mobile Home Approved.......................4
C. Glass Specifications.............................4
D. Electrical Rating...................................4
E. BTU & Efficiency Specifications...........4
Section 2: Getting Started
A. Design, Installation & Location
Considerations.....................................5
B. Locating Your Appliance & Chinmey...6
C. Thermostat Location............................6
D. Draft.....................................................6
E. Negative Pressure...............................6
F. Fire Safety...........................................7
G. Tools & Supplies Needed....................7
H. Inspect Appliance & Components.......7
Section 3: Dimensions & Clearances
A. Appliance Dimensions.........................8
B. Clearances to Combustibles................9
C. Hearth Requirements..........................10
Section 4: Vent Information
A. Chimney & Exhaust Connection..........11
B. Venting Termination Requirements.....11
C. Equivalent Feet of Pipe........................12
D. Pipe Selection Chart.............................12
Section 5: Venting Systems
A. Alcove..................................................13
B. Through the Wall..................................14
C. Vertical.................................................15
D. Through the Wall & Vertical - Exterior..15
E. Vertial - Internal....................................16
E. Masonry...............................................16
F. Alternate Masonry................................16
Section 6: Mobile Home...................................17
Section 7: Appliance Set-Up
A. Outside Air Kit, Rear & Floor...............18
B. Top Vent Adapter ................................19
C. Rear Vent & Rear to Top Vent Adapter..19
D. Brick Set ..............................................20
E. Brick Clip .............................................20
F. Log Set Placement...............................21
G. Grille Assembly....................................21
H. Logo Installation...................................21
I.
Door Installation...................................22
J. Thermostat Installation.........................22
Section 8: Operating Instructions
A. Fuel Size & Material.............................23
B. General Operation Information............23
C. Before Your First Fire..........................24
D. Starting Your First Fire........................24
E. Fire Characteristics..............................24
F. Feed Rate Adjustment ........................24
G. Ignition Cycles.....................................25
H. Frequently Asked Questions...............25
Section 9: Troubleshooting.............................26-28
Section 10: Maintaining & Servicing Appliance
A. Proper Shutdown Procedures..............29
B. Quick Reference Maintenance Chart...29
C. General Maintenance & Cleaning........29-32
D. High Ash Fuel Content Maintenance...33
E. Blower Replacement............................33-34
F. Baffle Removal.....................................34
G. Igniter Replacement.............................34
H. Glass Replacement..............................35
Section 11: Reference Material
A. Component Functions & Locations......36-37
B. Component Locations (Drawings).......38
C. Exploded Drawings..............................39-40
D. Service Parts & Accessories...............41-45
E. Warranty Policy....................................46-47
F. Contact Information..............................48
TABLE OF CONTENTS
Safety Alert Key:
•
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
•
WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
•
CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
•
NOTICE: Indicates practices which may cause damage to the fireplace or to property.
December 16, 2011
R
CB 1200 Pellet Stove
1
Listing and Code Approvals
A. Appliance Certification
C. Glass Specifications
E. BTU & Efficiency Specifications
This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
B. Mobile Home Approved
NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E1509-95, ULC S627-M93, ULC/ORD-C-1482-
M1990, (UM) 84-HUD
D. Electrical Rating
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps
*BTU output will vary, depending on the brand of fuel you
use in your stove. Consult your Quadra-Fire dealer for
best results.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifications and/or price without notice.
Emissions Rating
0..9 grams/hr
*BTU Output
14,000 - 40,000 / hr
Heating Capacity
up to 2,500 sq. ft. depending
on climate zone
Hopper Capacity
80 lbs
Fuel
Wood Pellets or Shelled Corn
Shipping Weight
349 lbs
Model
CB1200 Pellet Stove
Laboratory
OMNI Test Laboratories, Inc.
Report No.
061-S-21-4
Type
Solid Fuel Room Heater/Pellet Fuel
BurningType
Standard
ASTM E1509-95, ULC S627-M93 and
ULC/ORD-C1482-M1990 Room Heater
Pellet Fuel Burning type and (UM) 84-
HUD, Mobile Home Approved.
State Listing
Colorado, Listed 09-13-05
NOTE: Some generator or battery back-up systems
may not be compatable with the micro-processor elec-
tronics on this appliance. Please consult the power
supply manufacturer for compatable systems.
WARNING! Risk of Fire! Hearth & Home Technologies
disclaims any responsibility for, and the warranty and agency
listing will be voided by the above actions.
DO NOT:
• Install or operate damaged appliance
• Modify appliance
• Install other than as instructed by Hearth & Home
Technologies
• Operate the appliance without fully assembling all
components
• Overfire
• Install any component not approved by Hearth &
Home Technologies
• Install parts or components not Listed or approved.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is used.
The structural integrity of the mobile home floor, ceiling, and
walls must be maintained.
The appliance must be properly grounded to the frame of
the mobile home and use only Listed pellet vent Class “L”
or “PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile
home installation. You must order the Outside Air Kit sepa-
rately.
Note: The appliance is also approved for installation
into a shop.
December 16, 2011
7014-179D
Page 5
CB 1200 Pellet Stove
A. Design, Installation & Location Consider-
ations
Warning! Risk of Fire Damaged parts could impair safe
operation. Do NOT install damaged, incomplete or substitute
components.
1. Appliance Location
NOTICE: Check building codes prior to installation.
•
Installation MUST comply with local, regional, state and
national codes and regulations.
•
Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation
Consideration must be given to:
• Safety, convenience, traffic flow
• Placement of the chimney and chimney connector.
• If you are not using an existing chimney, place the appli-
ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.
• Installing an optional outside air kit would affect the loca-
tion of the vent termination.
CAUTION! If burning shelled field corn, you must use ap-
proved venting specifically designed for corn to prevent corro-
sion or degradation. Follow the instructions from the venting
manufacturer.
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
• Windows
• Air Intakes
• Air Conditioner
• Overhang, soffits, porch roofs, adjacent walls
• Landscaping, vegetation
When locating vent and venting termination, vent above roof
line when possible.
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
• Wind loading possible
NOTICE: Locating the appliance in a location of
considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near:
•
Frequently open doors
•
Central heat outlets or returns
Figure 5.1
2
Getting Started
December 16, 2011
R
CB 1200 Pellet Stove
C. Thermostat Location
The thermostat’s location will have some effect on the
appliance’s operation. When the thermostat is located close
to the appliance, it may require a slightly higher temperature
setting to keep the rest of the house comfortable. If the
thermostat location is in an adjacent room or on a different
floor level, you will notice higher temperatures near the
appliance.
Fire Hazard.
WARNING
•
Do not operate appliance before reading
and understanding operating instructions.
• Failure to operate appliance properly may
cause a house fire.
B. Locating Your Appliance & Chimney
D. Draft
Draft is the pressure difference needed to vent appliances
successfully. When an appliance is drafting successfully, all
combustion byproducts are exiting the home through the
chimney.
Considerations for successful draft include:
•
Preventing negative pressure
•
Location of appliance and chimney
NOTICE: Hearth & Home Technologies assumes no
responsibility for the improper performance of the chimney
system caused by:
•
Inadequate draft due to environmental conditions
•
Downdrafts
•
Tight sealing construction of the structure
•
Mechanical exhausting devices
E. Negative Pressure
WARNING! Risk of Asphyxiation! Negative pressure can
cause spillage of combustion fumes and soot.
Negative pressure results from the imbalance of air avail-
able for the appliance to operate properly. It can be stron-
gest in lower levels of the house.
Causes include:
•
Exhaust fans (kitchen, bath, etc.)
•
Range hoods
•
Combustion air requirements for furnaces, water heaters
and other combustion appliances
•
Clothes dryers
•
Location of return-air vents to furnace or air conditioning
•
Imbalances of the HVAC air handling system
•
Upper level air leaks such as:
- Recessed lighting
- Attic hatch
- Duct leaks
To minimize the effects of negative air pressure:
•
Install the outside air kit with the intake facing prevailing
winds during the heating season
•
Ensure adequate outdoor air for all combustion appliances
and exhaust equipment
•
Ensure furnace and air conditioning return vents are not
located in the immediate vicinity of the appliance
•
Avoid installing the appliance near doors, walkways or
small isolated spaces
•
Recessed lighting should be a “sealed can” design
•
Attic hatches weather stripped or sealed
•
Attic mounted duct work and air handler joints and seams
taped or sealed
Location of the appliance and chimney will affect
performance.
•
Install through the warm airspace enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die-down of the fire.
•
Penetrate the highest part of the roof. This minimizes the
effects of wind loading.
•
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
•
Minimize the use of chimney offsets.
•
Consider the appliance location relative to floor and ceiling
and attic joists.
•
Take into consideration the termination requirements on
Page 11.
CAUTION
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVICING ANOTHER APPLIANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTON DUCT
OR SYSTEM.
• May allow flue gases to enter the house.
December 16, 2011
7014-179D
Page 7
CB 1200 Pellet Stove
H. Inspect Appliance & Components and
Pre-Burn Check List
Reciprocating Saw
Channel Locks
Hammer
Phillips Screwdriver
Tape Meausre
Plumb Line
Level
Framing Material
Hi-temp Caulking Material
Gloves
Safety Glasses
Framing Square
Electric Drill & Bits (1/4”)
1/4” Self-Tapping Screws
May also need:
Vent Support Straps
Venting Paint
Tools and building supplies normally required
for installation, unless installing into an existing
masonry fireplace:
G. Tools And Supplies Needed
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
WARNING
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
1.
Place the appliance in a location near the
final installation area and follow the proce-
dures below:
2.
Open the appliance and remove all the parts
and articles packed inside the Component
Pack. Inspect all the parts and glass for ship-
ping damage. Contact your dealer if any irregu-
larities are noticed.
3.
All safety warnings have been read and fol-
lowed.
4.
This Owner’s Manual has been read.
5.
Floor protection requirements have been met.
6.
Venting is properly installed.
7.
The proper clearances from the appliance and
chimney to combustible materials have been
met.
8.
The masonry chimney is inspected by a profes-
sional and is clean, or the factory built metal
chimney is installed according to the manufac-
turer’s instructions and clearances.
9.
The chimney meets the required minimum
height.
10.
All labels have been removed from the glass
door.
11.
Plated surfaces have been wiped clean, if
applicable.
12.
Thermostat or remote has been installed.
13.
A power outlet is available nearby.
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied with
unit).
• Do NOT Overfire
Or any such action that may cause a fire hazard.
WARNING
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
Fire Risk.
F. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
• Install at least one smoke detector on each floor of your
home.
• Locate smoke detector away from the heating appliance
and close to the sleeping areas.
• Follow the smoke detector manufacturer’s placement and
installation instructions and maintain regularly.
• Conveniently locate a Class A fire extinguisher to contend
with small fires.
• In the event of a hopper fire:
• Evacute the house immediately.
• Notify fire department.
December 16, 2011
R
CB 1200 Pellet Stove
3
Dimensions and Clearances
A. Appliance Dimensions
5.0 in
(127mm)
4-5/8 in
(118mm)
12-3/8 in
(314mm)
14-1/4 in
(362mm)
2-1/2 in
(64mm)
CL
8-1/6 in.
(205mm)
20- 7/16 in.
(519mm)
28-1/2 in. (724mm)
27-5/8 in.
(692mm)
25-3/4 in.
(654mm)
CL
10-3/4 in.
(273mm)
24-3/4 in.
(629mm)
25-3/4 in.
(629mm)
8-1/16 in.
(205mm)
CL
28-1/2 in.
(724mm)
26-1/2 in.
(673mm)
31-5/8 in.
(803mm)
Figure 8.4 - Front View
Figure 8.1 - Top View
Figure 8.3 - Side View
Figure 8.2 - Top View with Top Vent Adapter
December 16, 2011
7014-179D
Page 9
CB 1200 Pellet Stove
Straight Back Against
Wall
Inches
Millimeters
A
Back Wall to Appliance
2
51
B
Side Wall to Appliance
6
152
Corner Installation
Inches
Millimeters
C
Walls to Appliance
2
51
Vertical Installation
Inches
Millimeters
D
Back Wall to Flue Pipe
3
76
E
Side Wall to Top
6
152
F
Back Wall to Appliance
7.5
191
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches
Millimeters
G
Walls to Appliance
2
51
B. Clearances to Combustibles (UL and ULC)
D
E
F
A
B
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
WARNING
Failure to comply may cause house fire.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
C
C
G
G
Alcove Installation
Inches
Millimeters
Minimum Alcove Height
44
1117
Minimum Alcove Width
40-1/2
1029
Maximum Alcove Depth
36
915
Minimum Alcove Side Wall
6
152
Top of Unit to Combustibles
12-1/2
318
December 16, 2011
R
CB 1200 Pellet Stove
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible floor protec-
tion is recommended extending beneath the flue pipe
when installed with horizontal venting or under the top
vent adapter with vertical installation.
CANADA INSTALLATIONS: A non-combustible floor
protection extending beneath the flue pipe is required
with horizontal venting or under the top vent adapter with
vertical installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
L*
K
K
M
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.
Hearth Pad Requirements
Inches
Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
Figure 10.1
Figure 10.2
December 16, 2011
7014-179D
Page 11
CB 1200 Pellet Stove
Do not terminate vent in any enclosed or semi-enclosed
area such as a carport, garage, attic, crawl space, under a
sun deck or porch, narrow walkway or closely fenced area,
or any location that can build up a concentration of fumes
such as a stairwell, covered breezeway, etc.
CAUTION
A. Chimney and Exhaust Connection
1. Chimney & Connector: Use 3 or 4 inch (76-102mm)
diameter type "L" or "PL" venting system. It can be vented
vertically or horizontally.
2. Mobile Home: Approved for all Listed pellet vent. If using
the 3 inch (76mm) vertical top vent adapter kit or the 3
to 6 inch (76-152mm) top vent offset adapter, use Listed
double wall flue connector. A Quadra-Fire outside air kit
must be used with manufactured home installations.
3. Residential: The 3 inch (76mm) vertical top vent adapter
kit and the 3 to 6 inch (76-152mm) top vent offset adapter
are tested to use 24 gauge single wall flue connector or
Listed double wall flue connector to Class A Listed metal
chimneys, or masonry chimneys meeting national and/or
local codes for solid fuel appliances.
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
5. Secure exhaust venting system to the appliance with at least
3 screws. Also secure all connector pipe joints with at least
3 screws through each joint.
6. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
7. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
NOTE: All pipe must be welded seam pipe whenever pos-
sible. Seal pipe joints with high temperature silicone (500°F
[260°C] minimum rated only). Do not put silicone inside
of pipe.
NOTE: If burning shelled field corn, you must use approved
venting specifically designed for corn. Follow the instruc-
tions from the venting manufacturer.
Fire Hazard.
• Only LISTED venting components may be
used.
• NO OTHER vent components may be used.
Substitute or damaged vent components may
impair safe operation.
WARNING
B. Venting Termination Requirements
1. Termination must exhaust above air inlet elevation. It is
recommended that at least 60 inches (1524mm) of verti-
cal pipe be installed when appliance is vented directly
through a wall. This will create a natural draft, which
will help prevent the possibility of smoke or odor venting
into the home during a power outage. It will also keep
exhaust from causing a nuisance or hazard by exposing
people or shrubs to high temperatures. The safest and
preferred venting method is to extend the vent vertically
through the roof.
2. Distance from doors and opening windows, or gravity or
ventilation air inlets into building:
a. Not less than 48 inches (1.2m) below;
b. Not less than 48 inches (1.2m) horizontally from;
c. Not less than 12 inches (305mm) above.
3. Distance from permanently closed windows:
a. Not less than 12 inches (305mm) below, horizontally
from or above.
4. Distance between bottom of termination and grade
should be 12 inches (305mm) minimum. This is con-
ditional upon plants in the area, and nature of grade
surface. The grade surface must be a non-combustible
material (i.e., rock, dirt). The grade surface must not be
lawn. Distance between bottom of termination and public
walkway should be 84 inches (2134mm) minimum.
5. Distance to combustible materials must be 24 inches
(610mm) minimum. This includes adjacent buildings,
fences, protruding parts of the structure, roof overhang,
plants and shrubs, etc.
6. Termination Cap Location (Home Electrical Service)
• Side-to-side clearance is to be the same as minimum
clearance to vinyl inside corners.
• Clearance of a termination cap below electrical service
shall be the same as minimum clearance to vinyl soffits.
• Clearance of a termination cap above electrical service
will be 12 inches (305mm) minimum.
• Location of the vent termination must not obstruct or
interfere with access to the electrical service.
4
Vent Information
Vent surfaces get HOT, can cause burns if
touched. Noncombustible shielding or guards
may be required.
WARNING
December 16, 2011
R
CB 1200 Pellet Stove
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appli-
ance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
WARNING
The chart will help you in determining proper
venting size according to the equivalent feet of
pipe calculated above and the altitude above sea
level of this installation. Figure 12.2.
Locate the calculated equivalent feet of pipe on
the vertical left side of the chart. Move to the
right horizontally on the chart until you reach
your altitude above sea level.
If you fall below the diagonal line, 3 or 4 inch (76
to 102mm) pipe may be used. If it is anywhere
above the diagonal line, a 4 inch (102mm) diam-
eter pipe is required.
The chart reveals that a 90° elbow is 5 times as
restrictive to the flow of exhaust gases under
positive pressure as 1 foot of horizontal pipe, and
a foot of horizontal pipe is twice as restrictive as
a foot of vertical pipe.
D. Pipe Selection Chart
The table below can help you calculate the equivalent feet
of pipe which is a method used to determine pellet vent size.
Figure 12.1.
C. Equivalent Feet of Pipe
Example of 3 Elbow-Rear Vent Termination Calculaton
Figure 12.1
Fire Risk.
Do NOT pack insulation or other
combustibles between firestops.
• ALWAYS maintain specified clearances
around venting and firestop systems.
• Install firestops as specified.
Failure to keep insulation or other material
away from vent pipe may cause fire.
WARNING
3 in. or 4 in. (76mm or 102mm) Diameter Pipe
Equivalent Pipe
Length In Feet
ALTITUDE IN THOUSANDS OF FEET
0
20
30
1 2 3 4 5 6 7 8 9 10
4 in. (102mm) Diameter Pipe Only
10
Example 1
Example 2
Figure 12.2
3 ft
(914mm)
2 ft (609mm)
2 ft (609mm)
2 ft (609mm)
Pellet Venting
Component
# of
Elbows
Feet of
Pipe
Multipled
By
Equivalent
Feet
Components
Equivalent Feet
90o Elbow or Tee
3
X
5
15
45o Elbow
X
3
Horizontal Pipe
7
X
1
7
Vertical Pipe
2
X
0.5
1
Total Equivalent Feet
23
Note: This is a generic example and is not
intended to represent any specific fuel type.
Example 1: If the equivalent length of pipe is 23 feet
(7m)with altitude of 8,000 feet (2438m) you must use
4 inch (102mm) diameter type “L” or “PL” vent.
Example 2: If the equivalent length of pipe is 12 feet
(3.7m) with altitude of 6,000 feet (1829m) you may
use 3 or 4 inch (76 to 102mm) diameter type “L” or
“PL” vent
December 16, 2011
7014-179D
Page 13
CB 1200 Pellet Stove
5
Venting Systems
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
A. Alcove
Figure 13.1
All minimums listed are to a combustible surface.
A
C
B
D
Alcove Installation
Inches
Millimeters
A
Minimum Alcove Height
44
1117
B
Minimum Alcove Width
40-1/2
1029
C
Maximum Alcove Depth
36
915
D
Minimum Alcove Side Wall
6
152
not shown
Top of Unit to Combustibles
12-1/2
318
December 16, 2011
R
CB 1200 Pellet Stove
6 in.
(152mm)
Minimum
Non-combustible Hearth Pad
W all
Thimble
Horizontal
T ermination
Cap
2 in.
(51mm)
Minimum
6 in.
(152mm)
Minimum
From Glass
Straight Out
B. Through The Wall
Horizontal termination cap must be a minimum of 12 inches.
(305mm) from the wall. Approved for mobile home instal-
lations. Must use 3 or 4 inch (76-102mm) “L” or “PL” listed
pellet venting or listed double wall pipe and a Quadra-Fire
outside air kit in mobile homes.
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365
Figure 14.1
Figure 14.2
Wall
Thimble
Illustration shows venting going in both directions.
Choose which one is best for your installation.
2 in. (51mm)
Minimum
2 in. (51mm)
Minimum
6 in.
(152mm)
Minimum
6 in. (152mm)
Minimum
45 Degree
NOTICE:
Please note that while the minimum
clearance for the termination cap is 6
inches (152mm) there is the possibly
of soot buildup around the termina-
tion area. If this occurs we suggest
to move the termination further away
from the house to prevent it.
December 16, 2011
7014-179D
Page 15
CB 1200 Pellet Stove
We recommend a minimum of 60 in. (1.5m) vertical,
however above the eave is preferred.
Both installations are approved for mobile home instal-
lations. Must use 3 or 4 inch (76 to 102mm) “L” or
“PL” Listed pellet venting or listed double wall pipe and
Quadra-Fire outside air kit in mobile homes. Single
wall pipe is approved for residential installations only.
C. Vertical into Existing Class A Chimney
D. Through The Wall & Vertical - External
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
Clean-out
Cover
24 in. (610mm)
minimum
Ceiling Support
Class A Chimney
Connector Adapter
Top Vent Kit
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support Bracket
every 60 in. (1524mm)
24 in. (610mm)
Minimum
Rain Cap
Flashing
2 in. (51mm) Minimum
6 in. (152mm)
Minimum
Figure 15.1
Figure 15.2
E. Vertical - Internal - Typical Installation
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm) Min.
24 in.
(610mm)
Minimum
3 in. to 3 in.
(76-76mm)
Top Vent Kit
Clean-out Cover
Figure 15.3
December 16, 2011
R
CB 1200 Pellet Stove
Fire Hazard
Inspection of Chimney:
•
Masonry chimney must be in good condition.
•
Meets minimum standard of NFPA 211
•
Factory-built chimney must be minimum6 in. (152mm)
UL103 HT.
WARNING
E. Masonry
F. Alternate Masonry
Non-Combustible Hearth Pad
Airtight
Clean-out Door
Cleanout Cover
Sheathing
3 in. (76mm) Minimum
1 in. (25mm) Clearance
Flashing
Fireclay Flue
Liner with Airspace
Concrete Cap
1 in. (25mm) Clearance
with Firestop
6 in. (152mm)
Minimum
Non-Combustible Hearth Pad
Sheathing
2 in. (51mm) Minimum
1 in. (25mm)
Clearance
Flashing
Fireclay Flue Liner
withAirspace
Concrete Cap
6 in. (152mm)
Minimum
Airtight Clean-out Door
1 in. (25mm) Clearance
with Firestop
Figure 16.1
Figure 16.2
December 16, 2011
7014-179D
Page 17
CB 1200 Pellet Stove
6
Mobile Home
1.
An outside air inlet must be provided for the combustion
air and must remain clear of leaves, debris, ice and/or
snow. It must be unrestricted while the appliance is
in use to prevent room air starvation which causes
smoke spillage. Smoke spillage can also set off smoke
alarms.
2.
The combustion air duct system must be made of
metal. It must permit zero clearance to combustible
construction and prevent material from dropping into
the inlet or into the area beneath the dwelling and
contain a rodent screen.
3.
The appliance must be secured to the mobile home
structure by bolting it to the floor (using lag bolts) in two
places. Use the same holes that secured the appliance
to the shipping pallet.
4.
The appliance must be grounded with #8 solid copper
grounding wire or equivalent, terminated at each end
with an NEC approved grounding device.
5.
Refer to Clearances to Combustibles and floor pro-
tection requirements on pages 9 & 10 for listings to
combustibles and appropriate chimney systems.
6.
Use silicone to create an effective vapor barrier at
the location where the chimney or other component
penetrates to the the exterior of the structure.
7.
Follow the chimney manufacturer’s instructions when
installing the vent system for use in a mobile home.
8.
Installation shall be in accordance with the Manufactur-
ers Home & Safety Standard (HUD) CFR 3280, Part
24.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MANUFAC-
TURED HOME FLOOR, WALL AND CEILING/ROOF MUST
BE MAINTAINED.
Do NOT cut through:
• Floor joist, wall, studs or ceiling trusses.
• Any supporting material that would affect the structural
integrity.
NEVER INSTALL IN A SLEEPING ROOM.
WARNING
Installation must comply with Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
WARNING
You must use a Quadra-Fire Outside Air Kit
for installation in a mobile home.
A. Mobile Home Installation
Figure 17.1
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Spark Arrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Approved Class “L” or
“PL” Pellet Vent
December 16, 2011
R
CB 1200 Pellet Stove
7
Appliance Set-Up
A. Outside Air Kit Instructions
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose
clamps, 1 collar assembly, termination cap assembly, 1
trim ring, 12 screws.
a. Measure distance from floor to air vent opening in appli-
ance and mark location on wall.
Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
b. Use hose clamp to secure flex pipe to collar assembly.
c. Slide trim ring over flex pipe and run pipe through wall.
d. Attach hose to outside termination cap with second
hose clamp.
e. Secure termination cap to outside surface.
f.
Secure trim ring to interior wall.
g. Snip corners and remove plate. Figure 18.1.
h. Align and secure collar assembly with 2 of the 4 holes
as shown. Figure 18.2.
Tools Needed: Phillips head screw driver; wire cutters;
hole saw or jig saw.
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Figure 18.1
1. Rear Installation
Snip Corners
and remove
plate
Figure 18.2
Figure 18.3
a. Remove rear screen and set aside.
b. Install cover plate over hole in right rear floor.
c. Cut a 2 inch minimum hole in the floor to accommodate
flex hose.
d. Attach hose to termination cap.
e. Place rope under pedestal to close off air leaks.
Screen
Install Cover Plate
Seal Pedestal with 26 in. Rope
Figure 18.4
2. Floor Installation
NO
NO
Secure Collar
December 16, 2011
7014-179D
Page 19
CB 1200 Pellet Stove
3 to 3 inch Top Vent Adapter
3 to 6 inch Top Vent Offset Adapter
1.
Put a layer of high temperature silicone on the 3 inch
(76mm) exhaust outlet.
2.
Slide the top vent adapter onto the rear exhaust outlet
and adjust the assembly to a vertical position.
3.
Drill 4 holes with #26 drill bit (provided) into the back of
the appliance using the outer shield as a pattern (make
sure the assembly is vertical). Figure 19.1
4.
Install the 4 mounting screws.
5.
Install the vent pipe into the top vent adapter (be sure
to silicone all joints).
6
To clean the top vent adapter, open the clean-out cover.
See Figure 19.1
B. Top Vent Adapter Installation
Installing the Top Vent Adapter
3" - 6"
Offset
Adapter
3" - 3"
Top Vent
Adapter
Drill holes in back of
stove and secure with 4
screws, 2 on each side.
Clean Out
Cover
Figure 19.1
C. Rear Vent and Rear Vent to Top Vent
Adapter Installation
Clean-Out Cover
Clean-Out Cover
Figure 19.2 - Rear Vent Adapter
Figure 19.3 - Rear to Top Vent Adapter - 90o
1.
Put a layer of high temperature silicone on the 3 inch
(76mm) exhaust outlet.
2.
Slide the adapter onto the rear exhaust outlet and adjust
the assembly to the appropriate position.
3.
Install the vent pipe into the adapter (be sure to silicone
all joints)
December 16, 2011
R
CB 1200 Pellet Stove
D. Optional Brick Set Installation
1. Remove the baffle first, follow instructions on page 34.
2. Slide bottom of left rear brick in first; rotate top edge
toward rear of appliance and then rotate outer edge
toward rear of appliance, until brick slides into place.
Figure 20.1.
3. Repeat with right rear brick.
4. Place left side brick along left side of firebox, making sure
chamfered (beveled) back edge of brick fits snugly next
to rear brick. Figure 20.2.
5. Repeat with right side panel.
6. Complete brick set, correctly installed. Figure 20.3.
1
2
3
1
2
3
4
Figure 20.1
Figure 20.2
Figure 20.3
1. After the brick set has been installed, 2 brick clips need
to be installed on the outer edge of each baffle to hold
the brick set in place.
2. Remove 2 baffles from the appliance. Slide the baffle up
and the bottom edge should fall down and then lift the
baffle out.
3. Using pliers, bend the brick clip slightly past 90° in the
direction shown in Figure 20.4.
4. Position the brick clip as shown in Figure 20.4 and use
pliers to crimp around the outside edge of the baffle as
shown in Figure 20.5.
Note: Figure 20.5 shows the finished shape of the brick
clip, after being bent around the outside edge of
the baffle.
5. Slide the baffle back into place making sure that the brick
clip holds the side brick toward the wall of the firebox.
Push back on the sides so they will keep the rear bricks
in place. Repeat for opposite side.
Approximately
1 inch from corner
Top outside
corner of Baffle
Outside edge
of Baffle
Use pliers to crimp
Brick Clip around edge
Installed Clip
E. Brick Clip Installation
• Brick may have small wires protruding from
the back of brick.
WARNING
Risk of Injury.
Figure 20.4
Figure 20.5
1
December 16, 2011
7014-179D
Page 21
CB 1200 Pellet Stove
G. Optional Gold or Nickel Grille Assembly
1.
Place the front log in first as shown in Figure 21.1. Place
log between firepot and face of appliance with charred
area surrounding firepot.
2.
Set the left and right logs onto the front log, placing
the holes in the base of the left and right logs over the
locating pins in front log. See Figure 21.2. Ensure that
the charred ends are facing the firepot.
F. Optional Log Set Placement Instructions
CAUTION
Logs are FRAGILE. Use extreme care when handling or
cleaning logs.
NOTE:
Due to the abrasive nature of a pellet appliance fire, the
logs are not covered under warranty. Any placement varia-
tion other than shown here can cause excessive heat and
shall void the appliance warranty.
LOCATING PINS
Charred Areas in the Back
Top Log
Right
Top Log, Left
Front Log
Figure 21.1
Figure 21.2
Place 1 flap of
box lid into
opening for
stability
CAUTION: Do not open top all the way back so the weight is
supported by the hinges. It will damage the hinges. Prop the
top up with supporting brace or use shipping box as shown.
Align the 3 hoes in the stove
with the holes in the grille and
secure in place.
1. Remove grille from packaging.
2. Lift top up and place shipping box in vertically.
3. Place 1 flap of the box lid into opening for stability.
4. Align the 3 holes in the stove with the holes in the grille.
5. Use a Phillips screwdriver to secure in place.
6. Remove shipping box and lower top.
Install Logo
1. Remove logo from packaging.
2. The logo has 2 studs on the back.
3. Install the logo on the lower left side of the center
panel by pressing the 2 studs into the pre-drilled
holes. See Figure 21.4.
Do not open top all the way back so the weight of the
top is supported by the hinges. It will damage the
hinges. It will be necessary to prop the top up with
a supporting brace. You can use the shipping box as
shown in Figure 1.
CAUTION
Figure 21.3
H. Installing Logo
Figure 21.4
December 16, 2011
R
CB 1200 Pellet Stove
1.
A 12 volt AC thermostat is required to operate this pellet
appliance. You may use the included wall mount thermo-
stat or purchase an optional programmable thermostat
or remote control. It is equipped with an adjustable
heat anticipator. The current rating is .05 amps. The
anticipator needs to be adjusted to the lowest setting
available.
2.
When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for
accurate readings. The thermostat should be
mounted on an inside wall and not in direct line
with the appliance convection air.
NOTE: If the thermostat is located too close to the
appliance, you may need to set the temperature
setting slightly higher to maintain the desired
temperature in your home.
3.
There is a 4 screw terminal block located on the back
lower left corner of the stove directly above the power
cord inlet. The center 2 screws are for the thermostat
wires.
J. Thermostat Installation
Figure 22.1
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appli-
ance.
CAUTION
Power Outlet
Terminal Block.
Center 2 screws for
Thermostat Wires
I. Door Installation
To install door:
1. Carefully remove door from packaging.
2. Line up hinges with hinge pins on appliance body, and slide
door down until it sits securely on pins. Figure 22.1.
3. If door is plated, be sure to clean all plated surfaces and
glass with a glass cleaner to ensure all oils are removed
before your first burn.
4. Remove all labels from glass before burning appliance.
To adjust latches:
1. Close door securely.
2. Place rod in slot on the bracket on the door and close
latch.
3. Latch must close tightly enough to ensure an airtight
seal between the door and the body of the appliance. To
increase tension on the latch, turn the rod clockwise a few
turns, then attempt to close the latch, until it is snug. Do not
overtighten; you should be able to close the latch with your
hand. Figure 22.2.
4. After adjusting the latch, place a Phillips head screw driver
in the end of the rod, and tighten the nut with a wrench.
This will maintain the correct tension on the rod and latch.
Hinge
Hinge Pin
Rod and nut
Rod and nut
Figure 22.2
Figure 22.3
December 16, 2011
7014-179D
Page 23
CB 1200 Pellet Stove
8
Operating Instructions
A. Fuel Size And Material
1. Wood Pellets
Fuel pellets are made from sawdust or wood by-products. If the
source material is hardwood, they can have a higher mineral
content, creating more ash. Fuels containing bark will also have
higher ash content. Minerals and other noncombustible materials
such as sand will turn into a hard, glass-like substance called
a clinker when heated to the extreme temperatures our firepot
reaches. This is what forms clinkers in the bottom of the firepot.
Trees from different areas will vary in mineral content. That is
why some fuels produce more clinkers than others. Pellets are
manufactured in either 1/4 inch or 5/16 inch (6-8mm) diameter and
should be no more than 1-1/2 inches (38mm) in length. Pellet
lengths may even vary by lot from the same manufacturer which
is why the feed rate may need to be adjusted occasionally. If you
burn pellets longer than 1-1/2 inches (38mm) you may have
an inconsistent fuel feed rate and/or missed ignitions.
Pellet fuel quality can greatly fluctuate. We recommend using
premium grade fuel with ash content less than 1%. Even in some
fuel labeled “premium” ash content can vary from bag to bag and
possibly exceed 1%. High ash fuel, or lack of maintenance, can
cause the firepot to fill up and thus create a potential for smoking,
sooting and possible hopper fires.
Always burn dry fuel. Burning fuel with high moisture content takes
heat from the fuel and tends to cool the appliance, robbing heat
from your home. Damp pellet fuel can clog the feed system.
We recommend that you buy fuel in multi-ton lots whenever
possible. Buying large quantities of fuel at once will greatly
reduce the number of times the feed adjustments will need to be
made. However, we do recommend trying various brands before
purchasing multi-ton lots to ensure your satisfaction.
2. Shelled Field Corn
Extensive factory and field testing has demonstrated shelled
field corn to be an efficient and very economical fuel. We
recommend the use of a 50-50 blend of corn and wood pellets.
The only change in operation is that the feed rate may require
a slight adjustment. The BTU output of the appliance varies
slightly compared to pellets, depending on the quality of the
corn used. In cases where it is acceptable for the appliance to
run full time, 100% corn will work after the fire has been started
using wood pellets.
B. General Operating Information
1. Thermostat Calls For Heat
The appliance is like most modern furnaces; when the
thermostat calls for heat, your appliance will automatically
light and deliver heat. When the room is up to temperature
and the thermostat is satisfied, the red call light will go off and
the appliance will shut down.
2. Heat Output Controls
This appliance is equipped with a heat output control switch
that has three settings or burn rates; low, medium and high.
The appliance will turn on and off as the thermostat demands.
When the thermostat calls for heat, the appliance will start
up on the high setting for the first 4 minutes and 15 seconds,
then automatically switch to the burn rate for which it is set.
If the appliance is set at one of the lower settings, it will run
quieter but take longer to heat up an area than if it were set
at a higher burn rate. Regardless of the burn rate, when the
area is warm enough to satisfy the thermostat, the appliance
will shut off.
3. Fan Speed Switch
This switch will adjust the speed of the room distribution air
fan or convection blower on all three settings. This means
you have six different blower speeds available as there is a
high and low on each setting.
Heat
Output
Fan
Speed
Reset Button
Call Light
HIGH
HIGH
MED
LOW
LOW
Figure 23.1
Fire Risk.
Keep combustible materials, gasoline
and other flammable vapors and liquids
clear of appliance.
WARNING
• Do NOT store flammable materials in the appliance’s
vicinity.
• DO NOT USE GASOLINE, LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID OR
SIMILAR LIQUIDS TO START OR “FRESHEN UP” A
FIRE IN THIS HEATER.
• DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
• Keep all such liquids well away from the heater while it
is in use.
• Combustible materials may ignite.
Fire Risk.
WARNING
• High ash fuels, or lack of maintenance, can
cause the firepot to overfill. Follow proper
shutdown procedure if ash buildup exceeds
half way point in firepot.
• Failure to do so could result in smoking,
sooting and possible hopper fires.
December 16, 2011
R
CB 1200 Pellet Stove
E. Fire Characteristics
A properly adjusted fire with the heat output control switch set
on “high” has a short active flame pattern that extends out of
the firepot approximately 4 to 6 inches (102 to 152mm). If
the fire has tall flames with black tails and seems somewhat
lazy, the feed rate will need to be reduced. This is done by
sliding the fuel adjustment control rod down, which will reduce
the feed. If the fire is not 4 to 6 inches (102 to 152mm) tall,
slide the fuel adjustment control rod up to increase the feed.
A medium and low setting will give a shorter flame. The flame
will rise and fall somewhat. This is normal.
Figure 24.1
C. Before Your First Fire
1. First, make sure your appliance has been properly
installed and that all safety requirements have been met.
Pay particular attention to the fire protection, venting and
thermostat installation instructions.
2. Double check that the ash drawer and firebox are
empty!
3. Check the position of the thermocouple, located above
the firepot, and make sure that it protrudes approximately
3/4 inch (19mm) into the firepot.
4. Close the front door.
NOTICE: The tip of the thermocouple must be in contact
with the inside end of the thermocouple cover or missed
ignitions can occur.
The feed adjustment control rod is factory set, and should
be adequate for most fuels. The set screw is located at the
bottom of the hopper and set loose at the factory so the
fuel adjustment control rod will slide up and down by only
loosening the thumb screw at the top. See Figure 24.1. Do
not re-tighten bottom set screw.
However, if the flame height is too high or too low, you will
need to adjust the feed rate. Wait until the appliance has been
burning for 15 minutes before making your adjustments and
allow 15 minutes for feed adjustment to take effect.
1.
Loosen the thumb screw. Figure 24.1
2. Adjust the fuel adjustment control rod towards the "+"
symbol to increase the feed rate and flame height or
towards the "-" symbol, to decrease the feed rate and
flame height.
3. Re-tighten the thumb screw.
F. Feed Rate Adjustment Instructions
D. Starting Your First Fire
1. A thermostat is required for proper operation of this
appliance, except for corn. At this time, fill the hopper
with pellets, set the thermostat to its lowest setting. Plug
the power cord into nearby outlet.
2. The exhaust blower will stay on for approximately 10
minutes even though the thermostat is not calling for
heat. This is normal.
3. Locate the heat output control switch mounted on the
upper right corner of the right side panel. Switch it to
the high setting by pushing the top of the switch in, then
adjust the thermostat to its highest setting. The red call
light located on the upper right corner of the right side
panel will be on. This indicates the thermostat is calling
for heat.
4. The fuel feed system and the igniter should now be on.
5. For your first fire it will be necessary to press the reset
button every two minutes until pellets start to drop into
the firepot, then press button 1 more time. This will fill the
feed system and allow the appliance to begin dropping
pellets. The appliance will continue to run as long as the
thermostat is calling for heat.
6. Once the appliance has ignited, let the it burn for
approximately 15 minutes, then set the thermostat to the
desired room temperature. Adjust the heat output control
switch to the desired setting.
Fuel Adjustment
Rod
Thumb
Screw
Set Screw
December 16, 2011
7014-179D
Page 25
CB 1200 Pellet Stove
G. Ignition Cycles
1. During each ignition cycle, it is normal to see some
smoke in the firebox. The smoke will stop once the
fire starts.
2. The convection blower will automatically turn on after
your appliance has reached the set temperature on
the “high” setting. This blower transfers heat from your
appliance into the room, and will continue to run after
the thermostat has stopped calling for heat until the
appliance has cooled down.
3. Occasionally the appliance may run out of fuel and shut
itself down. When this happens, the red call light will
be on. To restart it, fill the hopper and press the reset
button. (See Figure 23.1, page 23). When you press
the reset button the red call light will go out. Release
the button and the light will come back on. You should
see a fire shortly. If not, follow the instructions on page
24, of “Starting Your First Fire”.
H. Frequently Asked Questions
Odors and vapors released during initial operation.
• Curing of high temperature paint.
• Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot floor open.
• Cleaning slide plates open.
Do NOT store fuel:
• Closer than required clearances to com-
bustibles to appliance
• Within space required for loading or ash
removal.
ISSUES
SOLUTIONS
1. Metallic noise.
1. Noise is caused by metal expanding and contracting as
it heats up and cools down, similar to the sound pro-
duced by a furnace or heating duct. This noise does not
affect the operation or longevity of your insert.
2.
Ash buildup on glass.
2. This is normal. Clean the glass.
3.
Glass has turned dirty.
3. Excessive build up of ash. The lower burn settings will
produce more ash, the higher burn settings produce
less. The more it burns on low the more frequent clean-
ing of the glass is required.
4.
Fire has tall flames with black tails and is lazy.
4. The feed rate needs to be reduced or the firepot needs
cleaning. Heat exchanger of exhaust blower needs
cleaning.
5.
Smokey start-up or puffs of smoke from the airwash. 5. Either the firepot is dirty or there is too much fuel at
start-up and not enough air. Close down feed rate 1/4
inch at a time until this no longer happens.
6.
Large flame at start-up.
6. This is normal. Flame will settle down once the fire is
established.
Back side of Firepot
Firepot floor left open
Figure 24.1 - DO NOT LEAVE FIREPOT FLOOR OPEN
December 16, 2011
R
CB 1200 Pellet Stove
9
Troubleshooting
With proper installation, operation, and maintenance your appliance will provide years
of trouble-free service. If you do experience a problem, this troubleshooting guide
will assist a qualified service person in the diagnosis of a problem and the corrective
action to be taken. This troubleshooting guide can only be used by a qualified
service technician.
Symptom
Possible Cause
Corrective Action
Plug in appliance - No
response.
No current to outlet.
7 amp fuse defective.
#3 snap disc tripped or defective.
Control box defective.
Check circuit breaker at service panel.
Replace fuse.
Reset or replace snap disc.
Replace control box.
Call light on. No fire.
No fuel in firepot.
Out of fuel.
#2 snap disc may be defective.
Vacuum switch not closing, no vacuum.
Control box defective.
Check hopper. Fill with fuel.
Replace snap disc.
Check exhaust blower is plugged in and
operating.
Check vacuum switch is plugged in.
Check vacuum hose is in good condition,
clear and connected at both ends.
Check thermocouple is in good condition
and plugged in properly.
Make sure venting system is clean.
Make sure front door is closed.
Replace control box.
Call light on. No fire.
Partially burned fuel in
firepot.
Firepot clean-out plate not closed.
Firepot is dirty (missed ignition).
Check that firepot clean-out plate is fully
closed.
Clean firepot. Make sure there is no clinker
in the firepot.
Clinkers may have to be broken up with
firepot scraper tool or other means.
Call light on. No fire.
Unburned pellets in
firepot.
Firepot clean-out plate not closed.
Firepot is dirty.
Ignition hole blocked.
Igniter not working.
Control box defective.
Check that firepot clean-out plate is fully
closed.
Clean firepot. Make sure there is not a
clinker in the firepot. Clinkers may have to
be pushed out of firepot with firepot scraper
tool or other means.
Scrape with solid piece of wire.
Remove ash drawer to see if igniter is
glowing red on start-up.
Check igniter wires for good connection.
Replace igniter using 1/4 inch male /female
spade connectors.
Replace control box.
Slow or smoky start-up.
Firepot clean-out plate not closed.
Firepot is dirty.
Excessive amount of fuel at start-up.
Check that firepot clean-out is fully closed.
Clean firepot. Make sure there is not a
clinker in the firepot. Clinkers may have to
pushed out of firepot with firepot scraper
tool or other means.
Reduce feed rate using feed rate adjust-
ment control rod located inside hopper.
December 16, 2011
7014-179D
Page 27
CB 1200 Pellet Stove
Symptom
Possible Cause
Corrective Action
Slow or smoky start-up
(Cont’d)
Dirty exhaust and/or venting system.
Check for ash build up in unit, includ-
ing behind rear panels, firebox, heat
exchanger, exhaust blower and venting.
Feed system fails to
start.
Out of fuel.
#2 snap disc may be defective.
Vacuum switch not closing. No vacuum.
Feed system jammed or blocked.
Feed spring not turning with feed motor.
Feed motor defective or not plugged in.
Check hopper, fill with fuel.
Replace snap disc. Firebox door must be
closed securely.
Check exhaust blower is plugged in and
operating.
Check vacuum switch is plugged in.
Check vacuum hose is in good condition,
clear and connected at both ends.
Check thermocouple is in good condition
and plugged in properly.
Make sure venting system is clean.
NOTE: High winds blowing into the vent-
ing system can pressurize the firebox
causing loss of vacuum.
Empty hopper of fuel. Use a wet/dry
vacuum cleaner to remove remaining fuel,
from hopper, including feed tube.
Check feed chute for obstructions.
Loosen 2 screws and jiggle feed assembly.
Check that set screw is tight on feed
spring shaft at end of feed motor.
Check connections on feed motor, replace
if defective.
No call light. Unit
does not begin start
sequence.
Thermostat not set to a high enough tempera-
ture.
Snap Disc #3 tripped.
No power.
Fuse blown.
Connections at thermostat and/or appliance not
making proper contact.
Defective thermostat or thermostat wiring.
Control box defective.
Adjust thermostat above room tempera-
ture.
Reset snap disc.
Connect to power.
Replace fuse.
Check connections at thermostat and
appliance.
Replace thermostat or wiring.
NOTE: To test thermostat and wiring, use
a jumper wire at the thermostat block on
the unit to by-pass thermostat and wiring.
Replace control box.
Unit fails to shut off.
Call light on.
Turn thermostat off.
If call light does not go out, disconnect
thermostat wires from unit. If call light
does go out, thermostat or wires are
defective.
December 16, 2011
R
CB 1200 Pellet Stove
Symptoms
Possible Cause
Corrective Action
Convection blower fails to
start.
#1 snap disc defective.
Blower not plugged in.
Blower is defective.
Control box is defective.
Replace snap disc.
Check that blower is plugged into wire har-
ness.
Replace blower.
Replace control box.
Exhaust blower fails to
start or does not shut off.
Blower not plugged in.
Blower is clogged with ash.
Blower is defective.
Control box is defective.
Check that blower is plugged into wire har-
ness.
Clean exhaust system.
Replace blower.
Replace control box.
Large, lazy flame, orange
color. Black ash on glass.
Dirty appliance.
Poor fuel quality, high ash content.
Firepot clean-out plate not completely
closed.
Excessive amount of fuel.
Clean unit, including firepot, heat exchang-
ers and venting system. Remove stainless
steel baffle from firebox to clean ash from
on top of baffle. Clean behind rear brick
panels. Change fuel brand to premium.
Check that firepot clean-out plate is fully
closed.
Reduce feed rate using feed rate adjustment
control rod located inside hopper.
Nuisance shutdowns.
Low flame.
Sawdust buildup in hopper.
Feed motor is reversing.
Defective thermocouple.
Defective control box.
Firepot more than 1/2 full.
Increase feed by opening feed rate adjust-
ment control rod located inside hopper.
Clean hopper, see page 31.
Check for good connections between feed
motor and wire harness.
Replace thermocouple.
Replace control box.
See page 33 for detailed instructions for
“High Ash Fuel Content Management”
Appliance calls for heat.
Call light illuminates.
Exhaust blower starts.
No feed or igniter.
Thermocouple is defective or not properly
plugged in.
Defective control box
Check connections on thermocouple or
replace if defective.
A flashing yellow light on the control box
indicates a problem with the thermocouple.
Replace control box.
December 16, 2011
7014-179D
Page 29
CB 1200 Pellet Stove
10
Maintaining & Servicing Your Appliance
C. General Maintenance
1. Types of Fuel
Depending on the type of fuel you are burning will dictate
how often you have to clean your firepot.
If the fuel you are burning has a high dirt or ash content
or you are burning shelled field corn, it may be necessary
to clean the firepot more than once a day.
Dirty fuel will cause clinkers to form in the firepot. A clinker
is formed when dirt, ash or a non-burnable substance is
heated to 2000°F (1093°C) and becomes glass-like. See
“D” page 33 in this section for more details on fuels with
high ash content.
Clinker
Figure 29.1 - Clinker
Shock and Smoke Hazard
• Turn down thermostat, let appliance completely
cool and exhaust blower must be off. Now you
can unplug appliance before servicing.
• Smoke spillage into room can occur if appliance
is not cool before unplugging.
• Risk of shock if appliance not unplugged before
servicing appliance.
CAUTION
A. Proper Shutdown Procedure
B. Quick Reference Maintenance Chart
Follow the detailed instructions found in this
section for each step listed as referenced in the
chart below.
Cleaning or Inspection
Frequency
Daily
Weekly Monthly
Yearly
Ash Pan
Every 5 bags of fuel
OR
X
Ash Removal from Firebox
More frequently depending on
the fuel type or ash build-up
OR
X
Beneath Heat Exchanger
Every 1 ton of fuel
OR
X
Blower, Combustion (Exhaust)
More frequently depending on
the fuel type
OR
X
Blower, Convection
More frequently depending on
operating environment
OR
X
Door Latch Inspection
Prior to heating season
OR
X
Exhaust Path
More frequently depending on
ash build-up
OR
X
Firebox - Prepare for Non-Burn Season
At end of heating season
OR
X
Firepot - Burning pellets - hardwood
Every 3 bags
OR
X
Firepot - Burning pellets - softwood
Every 5 bags
OR
X
Firepot - Burning Corn
Every 1 bag
OR
X
Glass
When clear view of firepot
becomes obscure
OR
X
Heat Exchanger & Drop Tube
Every 1 ton of fuel
OR
X
Hopper
Every 1 ton of fuel or when
changing fuel types
OR
X
Top Vent Adapter
More frequently depending on
the fuel type or ash build-up
OR
X
Venting System
More frequently depending on
the fuel type
OR
X
NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of
ash at the recommended interval or you see soot coming from the vent. Not properly
cleaning your appliance on a regular basis will void your warranty.
December 16, 2011
R
CB 1200 Pellet Stove
5. Disposal of Ashes
•
Frequency: As needed
•
By: Homeowner
Ashes should be placed in a metal container with a
tight-fitting lid. The closed container of ashes should
be placed on a non-combustible floor or on the ground,
well away from all combustible materials, pending final
disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the
closed container until all cinders have been thoroughly
cooled.
6. Cleaning Heat Exchanger Chambers & Drop Tube
•
Frequency: Weekly or every 1 ton of fuel
•
By: Homeowner
The amount of ash buildup in the firepot will be a good
guide to determine how often you should clean the heat
exchangers.
a. Allow the appliance to completely cool down before
pulling the cleaning rods. Turn the thermostat on and
then immediately off to start the exhaust blower on its
cycle time. It will pull fly ash out the exhaust instead
of into the room.
b. To access the cleaning rods lift the hopper lid. Both
black bent handle pull rods are located close to the
face of the appliance to the left and right side.
c. To clean, pull the rods straight out until it stops,
approximately 20 inches (508mm). Slide the rods
OUT and IN a couple of times.
WARNING
Heat exchanger cleaning rods may be warm
to the touch. For safety purposes wear
gloves.
Do not pull heat exchanger cleaning rods
while appliance is operating.
Push cleaning rods IN when done, DO NOT
leave cleaning rods OUT. Injury can occur.
2. Cleaning Firepot with Cleaning Rod & Firepot
Scraper
•
Frequency: Daily or more often as needed
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off. If you are
just cleaning the firepot, there is no need to unplug the
appliance.
b. Pull firepot cleaning rod OUT and IN a couple of times
to help shake debris loose. If rod is hard to pull, it may
be necessary to use your firepot clean-out tool to chip
away material that has built up on the bottom plate of
the firepot and to push out any clinkers. Larger clinkers
may have to be removed from the top of the firepot.
Corn clinkers can be especially difficult to break up.
c. The firepot floor plate must be fully closed when
finished. See Figure 28.1 on page 28.
4. Cleaning Ash Pan
•
Frequency: Weekly or every 5 bags of fuel
•
By: Homeowner
Locate the ash pan underneath the firepot and using a
slight pull up and out remove the ash pan. Empty into
a non-combustible container and re-install ash pan.
See Disposal of Ashes.
3. Ash Removal from Firebox
•
Frequency: Weekly or more frequently depending on
ash build-up.
•
By: Homeowner
a. Allow the appliance to completely cool down. There
must not be any hot ashes in the firebox during
cleaning. Turn the thermostat on and then immediately
off to start the exhaust blower on its cycle time. It will
pull fly ash out the exhaust instead of into the room.
b. Frequent cleaning of the ash in the firebox will help
slow down the build-up of ash in the exhaust blower
and vent system.
c. Open door. Remove ash with an ash vacuum or whisk
broom and small dust pan.
d. This ash is deposited in the same ash pan as the
firepot debris. The ash pan should be emptied every
time you clean the firebox. Remember to place the ash
and debris into a metal or non-combustible container.
See Disposal of Ashes.
WARNING
• NEVER pull firepot cleaning rods or cleaning
slide plates when appliance is operating. Hot
pellets may fall into ashpan and may start a
fire or have mis-starts due to lack of vacuum.
Fire Risk.
Disposal of Ashes
WARNING
• Ashes should be placed in metal container
with tight fitting lid.
• Ashes should be retained in closed container
until all cinders have thoroughly cooled.
December 16, 2011
7014-179D
Page 31
CB 1200 Pellet Stove
7. Cleaning Beneath Heat Exchanger
•
Frequency: Monthly or after burning 1 ton of fuel
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
.
b. A more thorough cleaning is needed to remove the
excess ash that is left behind from the use of the
cleaning rods for the heat exchanger tubes.
c. The ash will be resting on the back of the baffles. This
will require removing the baffles. Please refer to page
33 for instructions on removing the baffles.
9. Cleaning the Glass
•
Frequency: When clear view of the firepot becomes
obscure.
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Use a damp paper towel or any nonabrasive glass
cleaner. Wipe off with dry towel.
NOTE: There are heavy duty vacuum cleaners specifically
designed for solid fuel appliance cleaning.
8. Cleaning Exhaust Path
•
Frequency: Yearly or more frequently depending on
ash build-up.
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. Remove access door on the right of the appliance (4
screws).
c. Use a small vacuum hose attachment to clean area.
d. Re-install and close trap door.
Handle glass assembly with care.
When cleaning glass:
• Avoid striking, scratching or slamming
glass.
CAUTION
• Do NOT clean glass when it is hot.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white film.
• Refer to maintenance instructions.
13. Cleaning Exhaust Blower - Requires No Lubrication
•
Frequency: Yearly or as needed
•
By: Quality Service Technician/Homeowner
•
Task: Contact your local dealer.
14. Cleaning Convection Blower - Requires No
Lubrication
•
Frequency: Yearly or as needed
•
By: Qualified Service Technician
•
Task: Contact your local dealer.
12. Cleaning the Hopper
•
Frequency: Monthly or after burning 1 ton of fuel
•
By: Homeowner
After burning approximately 1 ton of fuel or changing
fuels you will need to clean the hopper to prevent saw-
dust build-up.
A combination of sawdust and pellets on the auger
reduces the amount of fuel supply to the firepot. This
can result in nuisance shutdowns and mis-starts.
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b
Empty the hopper of any remaining pellets.
c. Vacuum the hopper and feed tube.
10. Door Latch Inspection
•
Frequency: Prior to heating season
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To adjust, open the latch and pivot the holding rod out.
Loosen the jam nut on the rod.
c. With a Phillips head screw driver, turn the rod clockwise
to tighten. The latch handle should snap securely in
place when adjusted properly.
d. After adjusting the latch, be sure to tighten the jam nut
on the rod to hold the adjustment.
11. Door Gasket Inspection
•
Frequency: Prior to heating season
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To inspect the door rope (gasket), open the door and
see that the door rope extends approximately 1/8 inch
(3mm) to 3/16 inch (9.5mm) from the door rope chan-
nel.
c. It should show signs of compaction all the way around
the door where the rope contacts the face of the appli-
ance. Confirm there are no air leaks.
December 16, 2011
R
CB 1200 Pellet Stove
15. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
•
Frequency: Yearly or more frequently depending on
ash build-up.
•
By: Qualified Service Technician/Homeowner
Be sure the appliance is allowed to cool, has been unplugged
and the exhaust blower is off.
The products of combustion will contain small particles of fly
ash. The fly ash will collect in the exhaust venting system
and restrict the flow of the flue gases.
At start-up if there is incomplete combustion, or if there is a
shutdown or incorrect operation of the appliance it will lead
to some soot formation. This will collect in the exhaust vent-
ing system.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
17. Preparing Firebox for Non-Burn Season
•
Frequency: Yearly
•
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the firebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
• Use the Touch-Up paint supplied with the appliance;
or,
• Purchase paint from your local dealer.
• Must use a high-temperature paint made specifi-
cially for heating appliances.
Clean Out
Cover
Figure 32.1
16. Cleaning the Top Vent Adapter
a.
The appliance must be in complete shutdown and
the exhaust blower should be off. Allow the appli-
ance to completely cool down.
b.
Open the clean-out cover. See Figure 32.1.
c.
Sweep out any ash build-up.
NOTE: There are heavy duty vacuum cleaners specifi-
ically designed for solid fuel appliance cleaning.
Frequency: Yearly or more frequently depending on
ash build-up.
•
By: Homeowner
December 16, 2011
7014-179D
Page 33
CB 1200 Pellet Stove
Correct Flame Size, Yellow/White in Color
Correct
Figure 33.3
Ash Build Up in Firebox
Pellets Back Up
In Feed Tube
Firepot Overfills
Tall, Lazy Flame, Orange in Color
Incorrect
Figure 33.1
Figure 33.2
D. High Ash Fuel Content Maintenance
•
Frequency: When the ash build-up exceeds more
than half way up the firepot.
•
By: Homeowner
1. Convection Blower Replacement
a. Use proper shut down procedures to shut down the
appliance and let it completely cool.
b. The convection blower is located at the bottom rear
of the appliance. If an outside air kit is also installed,
depending on your particular installation you may or
may not have to remove the outside air flange. If you
do, remove the 2 screws using a Phillips head screw-
driver. You do not need to remove the flex pipe from
the flange.
c. Remove the lower rear screen by removing the 4
screws securing the screen to the unit.
d. The motor is mounted on a removable bracket. Remove the
2 screws just above the motor and the whole assembly will tilt
down and pull out.
e. Disconnect the wires from the blower. The wires coming
from the wiring harness are white, red and tan and the
wires coming from the blower are black, white and red.
The white connects to white, the red to red and black to
the tan color wire.
E. Blower Replacement
Figure 33.4
Remove 2 Screws
Remove 4 Screws
Outside Air
Flex Hose
Convection Blower
Poor quality pellet fuel, or lack of maintenance, can create
conditions that make the firepot fill quickly with ashes and
clinkers.
This condition makes the appliance susceptible to overfill-
ing the firepot with pellets which may result in smoking,
sooting and possible hopper fires. Figure 33.1 shows an
example where the firepot overfills, pellets back up into the
feed tube and ash has accumulated in the firebox.
An inefficient and non-economical method of burning of
fuel caused by poor quality pellet fuel is shown in Figure
33.2.
The correct flame size when good quality, premium pellet
fuel is burned is shown in Figure 33.3.
If the ash buildup exceeds the half way point in the firepot
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.
Fire Risk.
WARNING
• High ash fuels, or lack of maintenance, can
cause the firepot to overfill. Follow proper
shutdown procedure if ash buildup exceeds
half way point in firepot.
• Failure to do so could result in smoking,
sooting and possible hopper fires.
December 16, 2011
R
CB 1200 Pellet Stove
2. Exhaust Blower Replacement
G. Igniter Replacement
F. Baffle Removal
1.
Use proper shut down procedures to shut down the
appliance and let it completely cool down and then
unplug it and remove the ash drawer.
2.
Follow instructions to remove the ash pan found on
page 30. Remove the access plate directly above it
by removing the 2 screws just below the ash catcher.
3.
The wire leads to the igniter are connected to the wire
harness with 1/4 inch male / female spade connectors.
These wires will pull forward approximately 4 to 5
inches (102mm to 127mm). Disconnect the spade
connections and remove the igniter from the chamber.
Loosen the thumb screw and slide igniter out.
4.
Install new igniter into the chamber and tighten the
thumb screw. Re-connect the wires to the 2 leads with
the spade connectors.
5.
Remove right side panel and pull wire leads back
toward the rear of the appliance to take-up the 4 to 5
inches (102mm to 107mm) previously pulled out. This
will keep the wires out of the way of the ash drawer.
Double check that the igniter wires are clear of any
movement, i.e. ash drawer, firepot cleaning rod, etc.
6.
Re-install the ash drawer and side panel and re-connect
the power.
1. Use proper shut down procedures to shut down the
appliance and let it completely cool down.
2. Open right side panel and then open the door.
3. The 2 baffles are located at the top inside of firebox.
4. Place your hand on the baffle and slide it up and the
bottom edge will fall down and then you can lift the baffle
out. Repeat for the other side.
Igniter
Igniter Bracket
Thumb Screw
Figure 34.1
Remove existing blower:
a. Use proper shut down procedures to shut down the appli-
ance and let it completely cool and then unplug it.
b. Use an 11/32" wrench or nut driver to loosen and remove
the (6) nuts holding motor mount plate to the blower
housing on your stove.
c. Remove washer from beneath the terminal ring on the
grounding wire.
d. Pull motor/mounting plate from blower housing.
e. Scrape off old gasketing material from blower housing.
Install new blower:
f.
The blower and blower housing is shipped as a unit. It
is necessary to separate them at this point if you are
using the existing blower housing already installed on
the appliance:
g. Follow steps 2 and 3 above. Discard or set aside the new
blower housing.
h. Carefully remove gasketing from new housing and set
onto the blower housing.
Re-install blower to blower housing:
i.
Install blower on housing ensuring that wiring exits facing
the 8 o’clock position. Place the washer and then the
grounding wire on nearest mounting plate stud.
j.
Use nuts removed in step b to secure blower to hous-
ing.
k. Re-connect wiring (use jumper wire if necessary). Re-
connect power supply.
December 16, 2011
7014-179D
Page 35
CB 1200 Pellet Stove
H. Glass Replacement
• Glass is 5mm thick high temperature heat-
resistant ceramic glass.
• DO NOT REPLACE with any other material.
• Alternate material may shatter and cause
injury.
WARNING
Figure 35.1
Top & Bottom Frame
Door Latch
Side
Frame
Center Posts
Glass
Remove Door Latch First
and then Side Frame
Door Frame
shown with no
Glass or Glass
Frames
Remove 5 nuts from Bottom Frame
Figure 35.2
Handle glass with care.
• Inspect the gasket to ensure it is
undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass
assembly removed.
WARNING
• Do NOT operate with glass cracked, broken or scratched.
• Remove door from appliance and place face down
on a protected surface to avoid scratching the door.
• Remove all door rope.
1. Replacing Center Glass
NOTE: DO NOT LET Air Wash Spacers fall down from
top frame when removing and replacing center
glass.
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Using a nut driver remove the (5) bottom nuts and
remove the bottom glass frame. Figure 35.2.
c. Slightly bend up and out of the way the 2 center posts
and slide the glass out the bottom.
d. Slide new glass in, reposition the 2 center posts and
re-install bottom glass frame.
e. Re-rope the door.
2. Replacing Side Glass
NOTE: When removing the side glass with the door
latch, you must remove the door latch first
before removing the side frame. Use a pow-
ered Phillips head screw driver to remove the
4 screws.
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove side glass frame.
c. Loosen the top and bottom frame and slightly bend
up and out of the way.
d. Slide glass out the side and slide new glass in.
e. Re-install the side glass frame and tighten the top
and bottom frames.
f. Re-install the door latch, if applicable, and re-rope
the door.
December 16, 2011
R
CB 1200 Pellet Stove
11
Reference Materials
7. Heat Exchangers
The heat exchangers transfer hot air from the exhaust system
into convection air. Lift the stove top to access the heat
exchangers. There are 2 clean out rods located under the
heat exchangers.
8. Heat Output Switch
The heat output switch is located on the upper right side panel.
The function of the heat ouput switch is to regulate the burn
rates; low, medium, and high settings.
9. Hopper Switch
The hopper switch is located in the upper right hand corner
of the hopper. This switch is designed to shut down the feed
motor whenever the hopper lid is opened.
10. Igniter
The igniter is mounted on the base of the firepot. Combustion
air travels over the red hot igniter creating super heated air
that ignites the pellets.
11. Junction Box And Wiring Harness
The junction box is located on the right side of the appliance,
behind the interior shield. The junction box and wiring harness
are replaced as one component.
12. Power Supply
The power outlet is located on the back of the appliance,
lower right corner. Check the wall receptacle for 120 volt,
60 Hz (standard current). Make sure the outlet is grounded
and has the correct polarity. A good surge protector is
recommended.
13. Red Call Light
The red call light is on the front of the junction box, next to the
reset button. The function of the red call light is to indicate
that the thermostat is calling for heat.
14. Reset Button
The reset button is located on the right side of the apppliance
next to the red call light. The function of the button is to
momentarily open the thermostat circuit, which restarts the
system.
15. Thermocouple
The thermocouple is located on top of the firepot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control box
indicating the preset temperatures of the green and red lights
have been obtained.
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF
THE APPLIANCE.
2. Convection Blower
The convection blower is mounted at the bottom rear of the
appliance. There are 2 impellers, one on each side of the
motor. The convection blower pushes heated air through the
heat exchange system into the room.
3. Combustion (Exhaust) Blower
The combustion blower is mounted on the lower left side
on rear of appliance. The blower is designed to pull the
exhaust from the appliance and push it out through the
venting system.
4. Feed System
The feed system is located in the hopper under the feed
motor cover box on the left side of the appliance and can
be removed as an entire assembly. The assembly includes
the feed motor, mounting bracket, bearing and feed spring
(auger). The hollow feed spring (auger) pulls pellets up the
feed tube from the hopper area and drops them down the
feed chute into the firepot.
5. Firepot
The firepot is made of high quality ductile iron and has a
cleaning pull-out rod. The floor of the firepot opens for
cleaning when you pull out the rod. Be sure that the floor
returns to a completely closed position or your appliance will
not operate properly.
6. Fuse
The fuse is located on the front of the junction box on the
right side of the appliance. The fuse will blow should a short
occur and shut off power to the appliance.
NOTE:
Do NOT open the control box. This will void the
warranty. If you need to plug in or remove the control
box you must first unplug the appliance.
1. Control Box
a. The control box is located under a small cover in the
right rear corner of the inside of the hopper.
b. There is a light located inside of the control box. The
internal light will turn green when the appliance has
reached a temperature of 200oF (93°C) in the firepot
and will turn red when it reaches 600
oF (315°C).
c. There is also an internal blue light located in the upper
left corner of the control box. When you plug in the
appliance the blue light will automatically start blinking
1 blink every 10 seconds for the first 60 seconds and
then will stop.
A. Component Function & Location E
December 16, 2011
7014-179D
Page 37
CB 1200 Pellet Stove
16. Thermostat
The appliance is designed to run on a 12 volt AC thermostat.
The heat anticipator should be set on the lowest setting
available.
17. Snap Disc #1 (Convection Blower) 145°F
Snap disc #1 is located on the right side of the appliance on
the top of the heat exchanger box. There are 2 purple wires
connected to it. This snap disc turns the convection blower
on and off as needed. Power is always present at snap disc
#1.
18. Snap Disc #2 (Thermostat Override) 200°F
Snap disc #2 is also located on the right side of the appliance
between snap disc #1 and convection blower. There are 2
yellow wires connected to it. This snap disc will turn off the
feed system, which will turn off the appliance if an overfire
condition should occur or if the convection blower should fail
to operate.
19. Snap Disc #3 (Back Burn Protector) 250°F
Snap disc #3 is mounted on the back of the auger tube in
the right side of the appliance just below the feed motor and
has a red reset button. To access it remove the feed motor
cover box from inside the hopper. If the fire tries to burn
back into the feed system or push exhaust up the feed tube,
this snap disc will shut the entire system off. This disc must
be manually reset.
20. Vacuum Switch
The vacuum switch is located on the left side of the appliance
behind the inner shield. This switch turns the feed system on
when vacuum is present in the firebox. The vacuum switch
is a safety device to shut off the feed motor if the exhaust
or the heat exchanger system is dirty or plugged or if the
firebox door is open.
21. Wiring Harness
See Figure 37.1 below.
Figure 37.1
Thermocouple
Heat
Output
Switch
Thermostat
Block
Snap
Disc #2
Snap
Disc #1
Feed
Motor
Vacuum
Switch
Capacitor
Convection
Blower
Blower
Speed
Exhaust
Blower
Snap
Disc #3
Reset
Button
Call Light
Fuse
Yellow
Yellow
Purple
Purple
Red
Red
Orange
White
Blue
Blue
Black
Black
Gray
High Temp
High Temp
Igniter
Hopper
Switch
December 16, 2011
R
CB 1200 Pellet Stove
B. Component Locations
Heat
Output
Fan
Speed
Reset Button
Call Light
HIGH
HIGH
MED
LOW
LOW
Power Outlet
Terminal Block.
Center 2 screws for
Thermostat Wires
Outside Air
Flex Hose
Convection Blower
Cleaning Rods
Heat Exchanger Tubes
Figure 38.1
Figure 38.3
Figure 38.4
Figure 38.2
December 16, 2011
7014-179D
Page 39
CB 1200 Pellet Stove
C. Exploded Views
Figure 39.1
Service Parts
12/11
R
Classic Bay Freestanding
Pellet Stove
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
1
5
2
3
6
7
12
9
8
4
10
11
13
14
15
16
21
17
18
19
20
22
23
24
25
26
33
35
37
38
39
40
31
29
28
27
30
36
32
34
Part number list on following page.
December 16, 2011
R
CB 1200 Pellet Stove
Figure 40.1
B. Service Parts & Accessories
Service Parts
12/11
R
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
1
Top Assembly
with Hopper Lid
812-3940
1.1
Handle, Hopper Lid
200-0110
1.2
Lid, Hopper
410-4901
Bumper, Rubber
Pkg of 12
SRV224-0340/12
Y
Bushing, Hopper Lid
Qty: 2
812-1010
1.3
Top Assembly
Top Only
SRV410-4980
Magnetic Switch
7000-375
Y
2.1
Baffl e Assembly Left
Post 3619669
510-5350
2.2
Baffl e Assembly Right
Post 3619669
510-5360
3
Brick Set
811-0601
Brick Retainer Clips Assembly
Pkg of 2
SRV510-1020
4
Curtain Mount, Side Left
410-5251
5
Curtain, Side Left
812-3840
6
Curtain, Pedestal Side
Right or Left
410-5391
7
Casting, Exhaust Transition
180-0190
8
Blower, Combustion/Exhaust
812-3381
Y
9
Gasket, Exhaust Combustion Blower (between…)
...Motor & Housing
812-4710
Y
...Housing & Stove
240-0812
Y
Additional service part numbers appear on following page.
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
1.1
1.2
1.3
2.1
2.2
#1 Top Assembly
#2 Baffl e Assembly
December 16, 2011
7014-179D
Page 41
CB 1200 Pellet Stove
Service Parts
12/11
R
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
10.1
Rod/Linkage, Ez Clean
812-3850
Bolt, Firepot, 1-1/4” Long
Pkgo of 25
225-0120/25
Y
Knob, Ash Dump Control Rod
832-3020
Spring, Firepot
200-2050
10.2
Firepot Assembly
812-3351
Y
Bushing, Firepot
410-8320
Y
Floor, Firepot
414-0290
Y
Gasket, Firepot
510-0530
Y
10.3
Thermocouple Cover
Qty: 1
812-1322
Y
Pkg of 10
812-4920
Y
10.4
Thermocouple
812-0210
Y
10.5
Thermocouple Bracket W/Set Screw
812-3171
Y
10.6
Heating Element 6”, Loop Igniter
Qty: 1
812-3811
Y
Pkg of 10
812-4560
Y
Wing Thumb Screw 8-32 X 1/2
Pkg of 24
7000-223/24
Y
11
Door Assembly
Black
DR-CB12-MBK-B
Gold
DR-CB12-GD-B
Nickel
DR-CB12-NL-B
11.1
Hinge, Female
450-2910
11.2
Glass Assembly, Center - 13-7/8” W x 11” H
510-5400
Y
11.3
Glass Assembly, Side, 1 Pc - 5-1/8” W x 11” H
Interchangeable
510-5410
Y
11.4
Glass Retainer Assembly
510-5460
Door Rope, 7/8”, Field Cut to Size
8 Ft.
842-2350
Y
Gasket, Glass, Field Cut to Size
10 Ft.
833-0660
Additional service part numbers appear on following page.
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
10.1
10.2
10.3
10.4
10.5
10.6
11.1
11.4
11.3
11.2
#10 Firepot Assembly and Associated Parts
#11 Door Assembly
December 16, 2011
R
CB 1200 Pellet Stove
Service Parts
12/11
R
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
12
Bracket, Door Latch
410-4912
13
Ashpan
812-4050
Gasket, 7/16”
10 Ft
844-6730
Y
14
Panel, Front Access
410-5161
15
Exhaust Plenum Trap Door
812-4100
16
Exhaust Plenum Cleanout Plate
410-4871
17
Latch, Magnetic - For Side Curtain Air Defl ector
812-3821
Latch, Magnet
229-0631
18
Mount, Side Curtain, Right
410-5261
19
Curtain, Side Right
812-3800
20
Latch, Draw
229-0640
Y
21
Snap Disc, Convection Blower # 1
SRV230-0060
Y
22
Blower Convection
812-3370
Y
23
Snap Disc, 200 Open/40 D, # 2
SRV230-0900
Y
24
Director, Air, Large
410-8250
25
Director, Air, Small
410-8260
26
Grille, Louver
Black
LVGRL-CB12-BK-B
Gold
LVGRL-CB12-GD-B
Nickel
LVGRL-CB12-NL-B
Grille, Bar, Bottom
410-8330
27
Extension, Heat Shield Top
410-5322
28
Panel, Feed Motor Access
410-6220
29
Wire Harness, Junction box
SRV7000-154
Y
Block, Thermostat Term Dv
230-0690
Igniter Extension
7000-218
30
Panel, Rear Access, Bottom
410-5413
31
Defl ector, Air, Right Curtain
410-5105
32
Snap Disc, Manual Reset
SRV230-1290
Y
33
Panel, Rear Access, Top
410-4352
34
Vacuum Switch
SRV7000-531
Y
35
Control Board 3 Speed
SRV7000-205
Y
36
Cover, Control Box
410-6321
37
Feed Adjustment Plate
812-4170
38
Cover, Feed Motor
410-5311
Additional service part numbers appear on following page.
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
December 16, 2011
7014-179D
Page 43
CB 1200 Pellet Stove
Service Parts
12/11
R
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
39
Feed Motor Assembly
812-3690
Y
Bearing, Feed System, Nylon
410-0552
Y
39.1
Screw, 8-32 X 3/8 PH
Pkg of 40
225-0500/40
Y
39.2
Feed Motor
812-4421
Y
39.3
Collar, Set, 7/8
229-0520
39.4
Feed Bearong
SRV7000-598
Y
39.5
Mount, Feed Motor
410-7172
39.6
Gasket, Feed Motor
240-0731
Y
39.7
Feed Spring Assembly
SRV7027-024
Y
39.8
Screw, 5/16-18 X 1/4
Pkg of 25
225-0550/25
Y
40
Defl ector, Air, Left Curtain
410-4992
Additional service part numbers appear on following page.
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
39.1
39.2
39.3
39.4
39.5
39.6
39.7
39.8
#39 Feed Motor Assembly
December 16, 2011
R
CB 1200 Pellet Stove
Service Parts
12/11
R
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
Bracket, Snap Disc Mounting
410-2521
Call Light, Fluorescent - New Style Junction Box
SRV7000-122
Component Pack (Includes Firepot Cleanout Tool, Touch-
Up Paint, Power Cord, Wire Harness For Thermostat,
Owners Manual, Warranty Card, Consumers View Card &
“How To” Dvd)
812-3630
Cleanout Tool
414-1140
Y
Dvd Original Energy Stove
7000-440
Harness, Thermostat Wire
230-0810
Paint Touch-Up, 4 oz
812-0910
Power Cord
812-1180
Y
Fuse, Amp .7, Junction Box
Pkg of 10
812-0380/10
Y
Fuse, Amp .8, Control Box
Pkg of 10
812-3780/10
Y
Hinge Plate
812-4030
Hinge, Door, Male
450-2810
Hose, Vacuum, 5/32 Id - Field Cut to Size
Qty. 3 Ft. Req.
SRV240-0450
Y
Igniter Wire (5Ft) & (4) Ceramic Nuts
812-4520
Y
Rocker Switch, 3-Position
Heat Output
812-3500
Y
Switch, Rocker (Fan Speed)
812-3910
Thermocouple Grounding Kit
812-4980
Additional service part numbers appear on following page.
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
December 16, 2011
7014-179D
Page 45
CB 1200 Pellet Stove
Service Parts
12/11
R
CB1200M-MBK
Beginning Manufacturing Date: April 2009
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
ACCESSORIES
Collar, Offset, Top Vent
812-3570
Damper, 3 Inch - Tall Vertical Installs Only
PEL-DAMP3
Y
Damper, 4 Inch - Tall Vertical Installs Only
PEL-DAMP4
Log Set
811-0592
Log, Front
7027-219
Log, Rear Left
7027-221
Log, Rear Right
7027-220
Outside Air Kit, Floor
811-0570
Outside Air Kit, Rear
811-0872
Channel, Air Intake
413-7040
Cover, Outside Air Kit, Floor
411-1071
Hose, Alum Flex, 2 Inch x 3 Ft
Qty. 3 Ft. Req.
200-0860
Outside Air Cap Assembly
7001-044
Outside Air Collar Assembly
7001-045
Trim Plate, Outside Air Kit
412-7100
Smart-Batt Il
841-0970
Smart-Stat Il
841-0960
Thermostat, Mechanical
812-3760
Y
Thermostat, Programmable
811-0520
Top Vent Adapter
TPVNT-1
Vent Adapter, 90, Cleanout
811-0610
Vent Adapter, Rear
811-0620
FASTENERS
Avk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tool
RIVNUT-REPAIR
Y
Bolt, Shoulder, 5/16 X 1/4-20
Pkg of 20
223-0170/20
Y
Ceramic Nuts, (Igniter)
Pkg of 12
812-0730/12
Y
Nut, Keps Lock, 8-32
Pkg of 40
226-0060/40
Y
Nut, Ser Flange Small 1/4-20
Pkg of 24
226-0130/24
Y
Nut, Wing, 8-32
Pkg of 24
226-0160/24
Y
Screw, Pan Head Philips 10-32 X 3/8
Pkg of 40
21799A/40
Y
Screw, Pan Head Philips 8-32 X 3/4
Pkg of 24
229-1100/24
Y
Screw, Sheet Metal #8 X 1/2 S-Grip
Pkg of 40
12460/40
Y
Washer, 1/4 Sae
Pkg of 24
28758/24
Y
Washer, Sae, 3/8
Pkg of 3 ea.
832-0990
Y
Hearth & Home Technologies
1445 North Highway
Colville, WA 99114
Division of HNI INDUSTRIES
www.quadrafire.com
7014-179D
December 16, 2011
Page 48
CONTACT INFORMATION:
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534,
5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407,
5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099,
6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579,
6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064,
6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408,
2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.
Please contact your Quadra-Fire dealer with any questions or concerns.
For the number of your nearest Quadra-Fire dealer
visit our website at www.quadrafire.com
Date purchased/installed:
Serial Number:
Location on appliance:
Dealership purchased from:
Dealer phone:
Notes:
We recommend that you record the following pertinent
information for your CB1200 PELLET STOVE
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating and
maintenance instruc-
tions included.
• Leave this manual with
party responsible for use
and operation.
• Read, understand and
follow these instruc-
tions for safe installa-
tion and operation.
DO NOT
DISCARD