December 16, 2011

CLASSIC BAY 1200 PELLET STOVE O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US Owner’s Manual Installation and Operation CB1200M-MBK Model: DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instruc- tions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instruc- tions for safe installa- tion and operation. DO NOT DISCARD WARNING Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • Do not overfire - If any external part starts to glow, you are overfiring. Reduce feed rate. Overfiring will void your warranty. • Comply with all minimum clearances to com- bustibles as specified. Failure to comply may cause house fire. Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fire officials or authorities having jurisdic- tion about restrictions, installation inspection, and permits. CAUTION Tested and approved for wood pellets and shelled field corn fuel only. Burning of any other type of fuel voids your warranty. CAUTION WARNING Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture, draperies and other flammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. To obtain a French translation of this manual, please contact your dealer or visit www.quadrafire.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrafire.com NOTE

December 16, 2011

R CB 1200 Pellet Stove and Welcome to the Quadra-Fire Family! Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and perfor- mance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Devel- opment facility then employs the world’s most advanced tech- nology to achieve the optimum operation of our stoves, inserts and fireplaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection from design, to fabrication, to shipping. We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire. SAMPLE MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES: U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"]. 7014-079 DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE Made in China/Fait Aux Chine 1445 Highway North Colville, WA 99114 www.quadrafire.com A Back Wall to stove / Mur Arrière du poêle 2"/51mm B Side Wall to Cast Top / Mur De Côté du haut 6"/152mm CORNER INSTALLATION / NSTALLATION DU COIN : C Side Wall / Mur De Côté 2"/51mm VERTICAL ADAPTER KIT INSTALLATION: UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE: D Back Wall to Flue Pipe / Mur Arrière tuyau rigide 3"/76mm B Side Wall to Cast Top / Mur De Côté du haut 6"/152mm CORNER INSTALLATION WITH VERTICAL ADAPTER KIT: INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL: E Side Wall / Mur De Côté 2"/51mm ALCOVE INSTALLATION / INSTALLATION DE L' ALCÔVE: Max. Alcove Depth: / La profondeur maximum de l'alcôve 36"/914mm A Back Wall to stove / Mur Arrière du poêle 2"/51mm B Side Wall to Cast Top / Mur De Côté du haut 6"/152mm C Unit corner to diagonal wall / 2" (51mm) F Top of Unit to Combustibles / Du poêle du haut combustibles 12.5"/318mm Alcove vertical installation / Installation verticale de l'alcôve D Back Wall to Flue Pipe / Mur Arrière tuyau rigide 3"/76mm Floor protector must be noncombustible material, extending beneath heater and to the front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door. G = 2"/51mm H* = 2"/51mm I = 6"/152mm FLOOR PROTECTION / PROTECTION DU SOL Note 1: In residential installations, when using Parts 811-0580, (3" - 3" Top Vent Adapter) and 812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used. Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6" pour mur simple de calibre 24 peut être utilisé. Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and 812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector. An Outside Air Kit (Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation. Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), utilisez un tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées. *Non-combustible floor protection must extend beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation. RECOMMENDED IN USA; REQUIRED IN CANADA Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée. *Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT D B C C E E A B H* G G I A B C C F A D 2010 2011 2012 JAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909. Tested to: ASTM E1509-95, ULC/ORD-C-1482-M1990, ULC S627-M93 Room Heating Pellet Burning Type, APFI, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. Input Rating: 40,000 Btu's/hr Electrical Rating: 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS. Route power cord away from unit. Do not route cord under or in front of appliance. DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic available from your dealer. To start, set thermostat above room temperature, the stove will light automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's manual.Keep viewing and ash removal doors tightly closed during operation. Testé à: ASTM E1509-95, ULC/ORD-C 1482-M1990, ULC S627-M93 Room Heating. Pellet Burning Type, APFI, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS. Puissance de Rendement: 40,000 Btu's/hr Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur. Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres fermées hermétiquement durant l'opération. Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909. R Report / Rapport 061-S-21-4 CB 1200 Pellet Stove SERIAL NO. / NUMÉRO DU CAUTION: HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper. ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine. 007C O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION: Behind left side curtain on outside of hopper wall. Testing Lab & Report Number Serial Number Model Mfg Date NOTE: Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

December 16, 2011

7014-179D Page 3 CB 1200 Pellet Stove Section 1: Listing and Code Approvals A. Appliance Certifications.......................4 B. Mobile Home Approved.......................4 C. Glass Specifications.............................4 D. Electrical Rating...................................4 E. BTU & Efficiency Specifications...........4 Section 2: Getting Started A. Design, Installation & Location Considerations.....................................5 B. Locating Your Appliance & Chinmey...6 C. Thermostat Location............................6 D. Draft.....................................................6 E. Negative Pressure...............................6 F. Fire Safety...........................................7 G. Tools & Supplies Needed....................7 H. Inspect Appliance & Components.......7 Section 3: Dimensions & Clearances A. Appliance Dimensions.........................8 B. Clearances to Combustibles................9 C. Hearth Requirements..........................10 Section 4: Vent Information A. Chimney & Exhaust Connection..........11 B. Venting Termination Requirements.....11 C. Equivalent Feet of Pipe........................12 D. Pipe Selection Chart.............................12 Section 5: Venting Systems A. Alcove..................................................13 B. Through the Wall..................................14 C. Vertical.................................................15 D. Through the Wall & Vertical - Exterior..15 E. Vertial - Internal....................................16 E. Masonry...............................................16 F. Alternate Masonry................................16 Section 6: Mobile Home...................................17 Section 7: Appliance Set-Up A. Outside Air Kit, Rear & Floor...............18 B. Top Vent Adapter ................................19 C. Rear Vent & Rear to Top Vent Adapter..19 D. Brick Set ..............................................20 E. Brick Clip .............................................20 F. Log Set Placement...............................21 G. Grille Assembly....................................21 H. Logo Installation...................................21 I. Door Installation...................................22 J. Thermostat Installation.........................22 Section 8: Operating Instructions A. Fuel Size & Material.............................23 B. General Operation Information............23 C. Before Your First Fire..........................24 D. Starting Your First Fire........................24 E. Fire Characteristics..............................24 F. Feed Rate Adjustment ........................24 G. Ignition Cycles.....................................25 H. Frequently Asked Questions...............25 Section 9: Troubleshooting.............................26-28 Section 10: Maintaining & Servicing Appliance A. Proper Shutdown Procedures..............29 B. Quick Reference Maintenance Chart...29 C. General Maintenance & Cleaning........29-32 D. High Ash Fuel Content Maintenance...33 E. Blower Replacement............................33-34 F. Baffle Removal.....................................34 G. Igniter Replacement.............................34 H. Glass Replacement..............................35 Section 11: Reference Material A. Component Functions & Locations......36-37 B. Component Locations (Drawings).......38 C. Exploded Drawings..............................39-40 D. Service Parts & Accessories...............41-45 E. Warranty Policy....................................46-47 F. Contact Information..............................48 TABLE OF CONTENTS Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Indicates practices which may cause damage to the fireplace or to property.

December 16, 2011

R CB 1200 Pellet Stove 1 Listing and Code Approvals A. Appliance Certification C. Glass Specifications E. BTU & Efficiency Specifications This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. B. Mobile Home Approved NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM E1509-95, ULC S627-M93, ULC/ORD-C-1482- M1990, (UM) 84-HUD D. Electrical Rating 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps *BTU output will vary, depending on the brand of fuel you use in your stove. Consult your Quadra-Fire dealer for best results. NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice. Emissions Rating 0..9 grams/hr *BTU Output 14,000 - 40,000 / hr Heating Capacity up to 2,500 sq. ft. depending on climate zone Hopper Capacity 80 lbs Fuel Wood Pellets or Shelled Corn Shipping Weight 349 lbs Model CB1200 Pellet Stove Laboratory OMNI Test Laboratories, Inc. Report No. 061-S-21-4 Type Solid Fuel Room Heater/Pellet Fuel BurningType Standard ASTM E1509-95, ULC S627-M93 and ULC/ORD-C1482-M1990 Room Heater Pellet Fuel Burning type and (UM) 84- HUD, Mobile Home Approved. State Listing Colorado, Listed 09-13-05 NOTE: Some generator or battery back-up systems may not be compatable with the micro-processor elec- tronics on this appliance. Please consult the power supply manufacturer for compatable systems. WARNING! Risk of Fire! Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the above actions. DO NOT: • Install or operate damaged appliance • Modify appliance • Install other than as instructed by Hearth & Home Technologies • Operate the appliance without fully assembling all components • Overfire • Install any component not approved by Hearth & Home Technologies • Install parts or components not Listed or approved. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your dealer. Quadra-Fire is a registered trademark of Hearth & Home Technologies. This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is used. The structural integrity of the mobile home floor, ceiling, and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home and use only Listed pellet vent Class “L” or “PL” connector pipe. A Quadra-Fire Outside Air Kit must be installed in a mobile home installation. You must order the Outside Air Kit sepa- rately. Note: The appliance is also approved for installation into a shop.

December 16, 2011

7014-179D Page 5 CB 1200 Pellet Stove A. Design, Installation & Location Consider- ations Warning! Risk of Fire Damaged parts could impair safe operation. Do NOT install damaged, incomplete or substitute components. 1. Appliance Location NOTICE: Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation Consideration must be given to: • Safety, convenience, traffic flow • Placement of the chimney and chimney connector. • If you are not using an existing chimney, place the appli- ance where there will be a clear passage for a factory- built listed chimney through the ceiling and roof. • Installing an optional outside air kit would affect the loca- tion of the vent termination. CAUTION! If burning shelled field corn, you must use ap- proved venting specifically designed for corn to prevent corro- sion or degradation. Follow the instructions from the venting manufacturer. Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: • Windows • Air Intakes • Air Conditioner • Overhang, soffits, porch roofs, adjacent walls • Landscaping, vegetation When locating vent and venting termination, vent above roof line when possible. Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended: Outside Air Intake on windward side NOT recommended: Outside Air Intake on leeward side Recommended Location: • Above peak Recommended: • Insulated exterior chase in cooler climates Recommended Location: • Above peak • Inside heated space Location NOT recommended: • Too close to tree • Below adjacent structure • Lower roof line • Avoid outside wall Marginal Location: • Wind loading possible NOTICE: Locating the appliance in a location of considerable air movement can cause intermittent smoke spillage from appliance. Do not locate appliance near: • Frequently open doors • Central heat outlets or returns Figure 5.1 2 Getting Started

December 16, 2011

R CB 1200 Pellet Stove C. Thermostat Location The thermostat’s location will have some effect on the appliance’s operation. When the thermostat is located close to the appliance, it may require a slightly higher temperature setting to keep the rest of the house comfortable. If the thermostat location is in an adjacent room or on a different floor level, you will notice higher temperatures near the appliance. Fire Hazard. WARNING • Do not operate appliance before reading and understanding operating instructions. • Failure to operate appliance properly may cause a house fire. B. Locating Your Appliance & Chimney D. Draft Draft is the pressure difference needed to vent appliances successfully. When an appliance is drafting successfully, all combustion byproducts are exiting the home through the chimney. Considerations for successful draft include: • Preventing negative pressure • Location of appliance and chimney NOTICE: Hearth & Home Technologies assumes no responsibility for the improper performance of the chimney system caused by: • Inadequate draft due to environmental conditions • Downdrafts • Tight sealing construction of the structure • Mechanical exhausting devices E. Negative Pressure WARNING! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Negative pressure results from the imbalance of air avail- able for the appliance to operate properly. It can be stron- gest in lower levels of the house. Causes include: • Exhaust fans (kitchen, bath, etc.) • Range hoods • Combustion air requirements for furnaces, water heaters and other combustion appliances • Clothes dryers • Location of return-air vents to furnace or air conditioning • Imbalances of the HVAC air handling system • Upper level air leaks such as: - Recessed lighting - Attic hatch - Duct leaks To minimize the effects of negative air pressure: • Install the outside air kit with the intake facing prevailing winds during the heating season • Ensure adequate outdoor air for all combustion appliances and exhaust equipment • Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance • Avoid installing the appliance near doors, walkways or small isolated spaces • Recessed lighting should be a “sealed can” design • Attic hatches weather stripped or sealed • Attic mounted duct work and air handler joints and seams taped or sealed Location of the appliance and chimney will affect performance. • Install through the warm airspace enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fire. • Penetrate the highest part of the roof. This minimizes the effects of wind loading. • Locate termination cap away from trees, adjacent structures, uneven roof lines and other obstructions. • Minimize the use of chimney offsets. • Consider the appliance location relative to floor and ceiling and attic joists. • Take into consideration the termination requirements on Page 11. CAUTION • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. • DO NOT CONNECT TO ANY AIR DISTRIBUTON DUCT OR SYSTEM. • May allow flue gases to enter the house.

December 16, 2011

7014-179D Page 7 CB 1200 Pellet Stove H. Inspect Appliance & Components and Pre-Burn Check List Reciprocating Saw Channel Locks Hammer Phillips Screwdriver Tape Meausre Plumb Line Level Framing Material Hi-temp Caulking Material Gloves Safety Glasses Framing Square Electric Drill & Bits (1/4”) 1/4” Self-Tapping Screws May also need: Vent Support Straps Venting Paint Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace: G. Tools And Supplies Needed Inspect appliance and components for damage. Damaged parts may impair safe operation. WARNING • Do NOT install damaged components. • Do NOT install incomplete components. • Do NOT install substitute components. Report damaged parts to dealer. 1. Place the appliance in a location near the final installation area and follow the proce- dures below: 2. Open the appliance and remove all the parts and articles packed inside the Component Pack. Inspect all the parts and glass for ship- ping damage. Contact your dealer if any irregu- larities are noticed. 3. All safety warnings have been read and fol- lowed. 4. This Owner’s Manual has been read. 5. Floor protection requirements have been met. 6. Venting is properly installed. 7. The proper clearances from the appliance and chimney to combustible materials have been met. 8. The masonry chimney is inspected by a profes- sional and is clean, or the factory built metal chimney is installed according to the manufac- turer’s instructions and clearances. 9. The chimney meets the required minimum height. 10. All labels have been removed from the glass door. 11. Plated surfaces have been wiped clean, if applicable. 12. Thermostat or remote has been installed. 13. A power outlet is available nearby. • Installation and use of any damaged appliance. • Modification of the appliance. • Installation other than as instructed by Hearth & Home Technologies. • Installation and/or use of any component part not approved by Hearth & Home Technologies. • Operating appliance without fully assembling all components. • Operating appliance without legs attached (if supplied with unit). • Do NOT Overfire Or any such action that may cause a fire hazard. WARNING Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: Fire Risk. F. Fire Safety To provide reasonable fire safety, the following should be given serious consideration: • Install at least one smoke detector on each floor of your home. • Locate smoke detector away from the heating appliance and close to the sleeping areas. • Follow the smoke detector manufacturer’s placement and installation instructions and maintain regularly. • Conveniently locate a Class A fire extinguisher to contend with small fires. • In the event of a hopper fire: • Evacute the house immediately. • Notify fire department.

December 16, 2011

R CB 1200 Pellet Stove 3 Dimensions and Clearances A. Appliance Dimensions 5.0 in (127mm) 4-5/8 in (118mm) 12-3/8 in (314mm) 14-1/4 in (362mm) 2-1/2 in (64mm) CL 8-1/6 in. (205mm) 20- 7/16 in. (519mm) 28-1/2 in. (724mm) 27-5/8 in. (692mm) 25-3/4 in. (654mm) CL 10-3/4 in. (273mm) 24-3/4 in. (629mm) 25-3/4 in. (629mm) 8-1/16 in. (205mm) CL 28-1/2 in. (724mm) 26-1/2 in. (673mm) 31-5/8 in. (803mm) Figure 8.4 - Front View Figure 8.1 - Top View Figure 8.3 - Side View Figure 8.2 - Top View with Top Vent Adapter

December 16, 2011

7014-179D Page 9 CB 1200 Pellet Stove Straight Back Against Wall Inches Millimeters A Back Wall to Appliance 2 51 B Side Wall to Appliance 6 152 Corner Installation Inches Millimeters C Walls to Appliance 2 51 Vertical Installation Inches Millimeters D Back Wall to Flue Pipe 3 76 E Side Wall to Top 6 152 F Back Wall to Appliance 7.5 191 Installations with: 3 to 3 inch Top Vent Adapter and 3 to 6 inch Offset Adapter Kit Corner Installation Inches Millimeters G Walls to Appliance 2 51 B. Clearances to Combustibles (UL and ULC) D E F A B Fire Risk. Comply with all minimum clearances to combustibles as specified. WARNING Failure to comply may cause house fire. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. C C G G Alcove Installation Inches Millimeters Minimum Alcove Height 44 1117 Minimum Alcove Width 40-1/2 1029 Maximum Alcove Depth 36 915 Minimum Alcove Side Wall 6 152 Top of Unit to Combustibles 12-1/2 318

December 16, 2011

R CB 1200 Pellet Stove *L Exception for Horizontal Installations: USA INSTALLATIONS: A non-combustible floor protec- tion is recommended extending beneath the flue pipe when installed with horizontal venting or under the top vent adapter with vertical installation. CANADA INSTALLATIONS: A non-combustible floor protection extending beneath the flue pipe is required with horizontal venting or under the top vent adapter with vertical installation. Must extend 2 inches (51mm) beyond each side of pipe (shaded area) C. Hearth Pad Requirements (UL and ULC) L* K K M Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door. Hearth Pad Requirements Inches Millimeters K Sides 2 51 L* Back 2 51 M Front 6 152 Figure 10.1 Figure 10.2

December 16, 2011

7014-179D Page 11 CB 1200 Pellet Stove Do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etc. CAUTION A. Chimney and Exhaust Connection 1. Chimney & Connector: Use 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system. It can be vented vertically or horizontally. 2. Mobile Home: Approved for all Listed pellet vent. If using the 3 inch (76mm) vertical top vent adapter kit or the 3 to 6 inch (76-152mm) top vent offset adapter, use Listed double wall flue connector. A Quadra-Fire outside air kit must be used with manufactured home installations. 3. Residential: The 3 inch (76mm) vertical top vent adapter kit and the 3 to 6 inch (76-152mm) top vent offset adapter are tested to use 24 gauge single wall flue connector or Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting national and/or local codes for solid fuel appliances. 4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. 5. Secure exhaust venting system to the appliance with at least 3 screws. Also secure all connector pipe joints with at least 3 screws through each joint. 6. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. 7. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. NOTE: All pipe must be welded seam pipe whenever pos- sible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only). Do not put silicone inside of pipe. NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instruc- tions from the venting manufacturer. Fire Hazard. • Only LISTED venting components may be used. • NO OTHER vent components may be used. Substitute or damaged vent components may impair safe operation. WARNING B. Venting Termination Requirements 1. Termination must exhaust above air inlet elevation. It is recommended that at least 60 inches (1524mm) of verti- cal pipe be installed when appliance is vented directly through a wall. This will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage. It will also keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. The safest and preferred venting method is to extend the vent vertically through the roof. 2. Distance from doors and opening windows, or gravity or ventilation air inlets into building: a. Not less than 48 inches (1.2m) below; b. Not less than 48 inches (1.2m) horizontally from; c. Not less than 12 inches (305mm) above. 3. Distance from permanently closed windows: a. Not less than 12 inches (305mm) below, horizontally from or above. 4. Distance between bottom of termination and grade should be 12 inches (305mm) minimum. This is con- ditional upon plants in the area, and nature of grade surface. The grade surface must be a non-combustible material (i.e., rock, dirt). The grade surface must not be lawn. Distance between bottom of termination and public walkway should be 84 inches (2134mm) minimum. 5. Distance to combustible materials must be 24 inches (610mm) minimum. This includes adjacent buildings, fences, protruding parts of the structure, roof overhang, plants and shrubs, etc. 6. Termination Cap Location (Home Electrical Service) • Side-to-side clearance is to be the same as minimum clearance to vinyl inside corners. • Clearance of a termination cap below electrical service shall be the same as minimum clearance to vinyl soffits. • Clearance of a termination cap above electrical service will be 12 inches (305mm) minimum. • Location of the vent termination must not obstruct or interfere with access to the electrical service. 4 Vent Information Vent surfaces get HOT, can cause burns if touched. Noncombustible shielding or guards may be required. WARNING

December 16, 2011

R CB 1200 Pellet Stove Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appli- ance. For assistance or additional information consult a qualified installer, service agency or your dealer. WARNING The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated above and the altitude above sea level of this installation. Figure 12.2. Locate the calculated equivalent feet of pipe on the vertical left side of the chart. Move to the right horizontally on the chart until you reach your altitude above sea level. If you fall below the diagonal line, 3 or 4 inch (76 to 102mm) pipe may be used. If it is anywhere above the diagonal line, a 4 inch (102mm) diam- eter pipe is required. The chart reveals that a 90° elbow is 5 times as restrictive to the flow of exhaust gases under positive pressure as 1 foot of horizontal pipe, and a foot of horizontal pipe is twice as restrictive as a foot of vertical pipe. D. Pipe Selection Chart The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Figure 12.1. C. Equivalent Feet of Pipe Example of 3 Elbow-Rear Vent Termination Calculaton Figure 12.1 Fire Risk. Do NOT pack insulation or other combustibles between firestops. • ALWAYS maintain specified clearances around venting and firestop systems. • Install firestops as specified. Failure to keep insulation or other material away from vent pipe may cause fire. WARNING 3 in. or 4 in. (76mm or 102mm) Diameter Pipe Equivalent Pipe Length In Feet ALTITUDE IN THOUSANDS OF FEET 0 20 30 1 2 3 4 5 6 7 8 9 10 4 in. (102mm) Diameter Pipe Only 10 Example 1 Example 2 Figure 12.2 3 ft (914mm) 2 ft (609mm) 2 ft (609mm) 2 ft (609mm) Pellet Venting Component # of Elbows Feet of Pipe Multipled By Equivalent Feet Components Equivalent Feet 90o Elbow or Tee 3 X 5 15 45o Elbow X 3 Horizontal Pipe 7 X 1 7 Vertical Pipe 2 X 0.5 1 Total Equivalent Feet 23 Note: This is a generic example and is not intended to represent any specific fuel type. Example 1: If the equivalent length of pipe is 23 feet (7m)with altitude of 8,000 feet (2438m) you must use 4 inch (102mm) diameter type “L” or “PL” vent. Example 2: If the equivalent length of pipe is 12 feet (3.7m) with altitude of 6,000 feet (1829m) you may use 3 or 4 inch (76 to 102mm) diameter type “L” or “PL” vent

December 16, 2011

7014-179D Page 13 CB 1200 Pellet Stove 5 Venting Systems NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. A. Alcove Figure 13.1 All minimums listed are to a combustible surface. A C B D Alcove Installation Inches Millimeters A Minimum Alcove Height 44 1117 B Minimum Alcove Width 40-1/2 1029 C Maximum Alcove Depth 36 915 D Minimum Alcove Side Wall 6 152 not shown Top of Unit to Combustibles 12-1/2 318

December 16, 2011

R CB 1200 Pellet Stove 6 in. (152mm) Minimum Non-combustible Hearth Pad W all Thimble Horizontal T ermination Cap 2 in. (51mm) Minimum 6 in. (152mm) Minimum From Glass Straight Out B. Through The Wall Horizontal termination cap must be a minimum of 12 inches. (305mm) from the wall. Approved for mobile home instal- lations. Must use 3 or 4 inch (76-102mm) “L” or “PL” listed pellet venting or listed double wall pipe and a Quadra-Fire outside air kit in mobile homes. NOTE: In Canada, where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365 Figure 14.1 Figure 14.2 Wall Thimble Illustration shows venting going in both directions. Choose which one is best for your installation. 2 in. (51mm) Minimum 2 in. (51mm) Minimum 6 in. (152mm) Minimum 6 in. (152mm) Minimum 45 Degree NOTICE: Please note that while the minimum clearance for the termination cap is 6 inches (152mm) there is the possibly of soot buildup around the termina- tion area. If this occurs we suggest to move the termination further away from the house to prevent it.

December 16, 2011

7014-179D Page 15 CB 1200 Pellet Stove We recommend a minimum of 60 in. (1.5m) vertical, however above the eave is preferred. Both installations are approved for mobile home instal- lations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or listed double wall pipe and Quadra-Fire outside air kit in mobile homes. Single wall pipe is approved for residential installations only. C. Vertical into Existing Class A Chimney D. Through The Wall & Vertical - External Firestop Flashing Rain Cap 6 in. (152mm) Min. Non-combustible Hearth Pad 3 in. (76mm) Min. Clean-out Cover 24 in. (610mm) minimum Ceiling Support Class A Chimney Connector Adapter Top Vent Kit Non-combustible Hearth Pad Clean-out Cover Tee Wall Thimble Support Bracket every 60 in. (1524mm) 24 in. (610mm) Minimum Rain Cap Flashing 2 in. (51mm) Minimum 6 in. (152mm) Minimum Figure 15.1 Figure 15.2 E. Vertical - Internal - Typical Installation Firestop Flashing Rain Cap 6 in. (152mm) Min. Non-combustible Hearth Pad 3 in. (76mm) Min. 24 in. (610mm) Minimum 3 in. to 3 in. (76-76mm) Top Vent Kit Clean-out Cover Figure 15.3

December 16, 2011

R CB 1200 Pellet Stove Fire Hazard Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be minimum6 in. (152mm) UL103 HT. WARNING E. Masonry F. Alternate Masonry Non-Combustible Hearth Pad Airtight Clean-out Door Cleanout Cover Sheathing 3 in. (76mm) Minimum 1 in. (25mm) Clearance Flashing Fireclay Flue Liner with Airspace Concrete Cap 1 in. (25mm) Clearance with Firestop 6 in. (152mm) Minimum Non-Combustible Hearth Pad Sheathing 2 in. (51mm) Minimum 1 in. (25mm) Clearance Flashing Fireclay Flue Liner withAirspace Concrete Cap 6 in. (152mm) Minimum Airtight Clean-out Door 1 in. (25mm) Clearance with Firestop Figure 16.1 Figure 16.2

December 16, 2011

7014-179D Page 17 CB 1200 Pellet Stove 6 Mobile Home 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes smoke spillage. Smoke spillage can also set off smoke alarms. 2. The combustion air duct system must be made of metal. It must permit zero clearance to combustible construction and prevent material from dropping into the inlet or into the area beneath the dwelling and contain a rodent screen. 3. The appliance must be secured to the mobile home structure by bolting it to the floor (using lag bolts) in two places. Use the same holes that secured the appliance to the shipping pallet. 4. The appliance must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with an NEC approved grounding device. 5. Refer to Clearances to Combustibles and floor pro- tection requirements on pages 9 & 10 for listings to combustibles and appropriate chimney systems. 6. Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the the exterior of the structure. 7. Follow the chimney manufacturer’s instructions when installing the vent system for use in a mobile home. 8. Installation shall be in accordance with the Manufactur- ers Home & Safety Standard (HUD) CFR 3280, Part 24. CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFAC- TURED HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED. Do NOT cut through: • Floor joist, wall, studs or ceiling trusses. • Any supporting material that would affect the structural integrity. NEVER INSTALL IN A SLEEPING ROOM. WARNING Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. WARNING You must use a Quadra-Fire Outside Air Kit for installation in a mobile home. A. Mobile Home Installation Figure 17.1 CAUTION Never draw outside combustion air from: • Wall, floor or ceiling cavity • Enclosed space such as an attic or garage Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield/Firestop Approved Class “L” or “PL” Pellet Vent

December 16, 2011

R CB 1200 Pellet Stove 7 Appliance Set-Up A. Outside Air Kit Instructions Flex Hose Hose Clamp Collar Assembly Trim Ring Termination Cap Assembly Hose Clamp Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose clamps, 1 collar assembly, termination cap assembly, 1 trim ring, 12 screws. a. Measure distance from floor to air vent opening in appli- ance and mark location on wall. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch (64-76mm) opening on inside wall and a 3 to 3-1/2 inch (76-89mm) opening on outside of house. b. Use hose clamp to secure flex pipe to collar assembly. c. Slide trim ring over flex pipe and run pipe through wall. d. Attach hose to outside termination cap with second hose clamp. e. Secure termination cap to outside surface. f. Secure trim ring to interior wall. g. Snip corners and remove plate. Figure 18.1. h. Align and secure collar assembly with 2 of the 4 holes as shown. Figure 18.2. Tools Needed: Phillips head screw driver; wire cutters; hole saw or jig saw. CAUTION Never draw outside combustion air from: • Wall, floor or ceiling cavity • Enclosed space such as an attic or garage Figure 18.1 1. Rear Installation Snip Corners and remove plate Figure 18.2 Figure 18.3 a. Remove rear screen and set aside. b. Install cover plate over hole in right rear floor. c. Cut a 2 inch minimum hole in the floor to accommodate flex hose. d. Attach hose to termination cap. e. Place rope under pedestal to close off air leaks. Screen Install Cover Plate Seal Pedestal with 26 in. Rope Figure 18.4 2. Floor Installation NO NO Secure Collar

December 16, 2011

7014-179D Page 19 CB 1200 Pellet Stove 3 to 3 inch Top Vent Adapter 3 to 6 inch Top Vent Offset Adapter 1. Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet. 2. Slide the top vent adapter onto the rear exhaust outlet and adjust the assembly to a vertical position. 3. Drill 4 holes with #26 drill bit (provided) into the back of the appliance using the outer shield as a pattern (make sure the assembly is vertical). Figure 19.1 4. Install the 4 mounting screws. 5. Install the vent pipe into the top vent adapter (be sure to silicone all joints). 6 To clean the top vent adapter, open the clean-out cover. See Figure 19.1 B. Top Vent Adapter Installation Installing the Top Vent Adapter 3" - 6" Offset Adapter 3" - 3" Top Vent Adapter Drill holes in back of stove and secure with 4 screws, 2 on each side. Clean Out Cover Figure 19.1 C. Rear Vent and Rear Vent to Top Vent Adapter Installation Clean-Out Cover Clean-Out Cover Figure 19.2 - Rear Vent Adapter Figure 19.3 - Rear to Top Vent Adapter - 90o 1. Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet. 2. Slide the adapter onto the rear exhaust outlet and adjust the assembly to the appropriate position. 3. Install the vent pipe into the adapter (be sure to silicone all joints)

December 16, 2011

R CB 1200 Pellet Stove D. Optional Brick Set Installation 1. Remove the baffle first, follow instructions on page 34. 2. Slide bottom of left rear brick in first; rotate top edge toward rear of appliance and then rotate outer edge toward rear of appliance, until brick slides into place. Figure 20.1. 3. Repeat with right rear brick. 4. Place left side brick along left side of firebox, making sure chamfered (beveled) back edge of brick fits snugly next to rear brick. Figure 20.2. 5. Repeat with right side panel. 6. Complete brick set, correctly installed. Figure 20.3. 1 2 3 1 2 3 4 Figure 20.1 Figure 20.2 Figure 20.3 1. After the brick set has been installed, 2 brick clips need to be installed on the outer edge of each baffle to hold the brick set in place. 2. Remove 2 baffles from the appliance. Slide the baffle up and the bottom edge should fall down and then lift the baffle out. 3. Using pliers, bend the brick clip slightly past 90° in the direction shown in Figure 20.4. 4. Position the brick clip as shown in Figure 20.4 and use pliers to crimp around the outside edge of the baffle as shown in Figure 20.5. Note: Figure 20.5 shows the finished shape of the brick clip, after being bent around the outside edge of the baffle. 5. Slide the baffle back into place making sure that the brick clip holds the side brick toward the wall of the firebox. Push back on the sides so they will keep the rear bricks in place. Repeat for opposite side. Approximately 1 inch from corner Top outside corner of Baffle Outside edge of Baffle Use pliers to crimp Brick Clip around edge Installed Clip E. Brick Clip Installation • Brick may have small wires protruding from the back of brick. WARNING Risk of Injury. Figure 20.4 Figure 20.5 1

December 16, 2011

7014-179D Page 21 CB 1200 Pellet Stove G. Optional Gold or Nickel Grille Assembly 1. Place the front log in first as shown in Figure 21.1. Place log between firepot and face of appliance with charred area surrounding firepot. 2. Set the left and right logs onto the front log, placing the holes in the base of the left and right logs over the locating pins in front log. See Figure 21.2. Ensure that the charred ends are facing the firepot. F. Optional Log Set Placement Instructions CAUTION Logs are FRAGILE. Use extreme care when handling or cleaning logs. NOTE: Due to the abrasive nature of a pellet appliance fire, the logs are not covered under warranty. Any placement varia- tion other than shown here can cause excessive heat and shall void the appliance warranty. LOCATING PINS Charred Areas in the Back Top Log Right Top Log, Left Front Log Figure 21.1 Figure 21.2 Place 1 flap of box lid into opening for stability CAUTION: Do not open top all the way back so the weight is supported by the hinges. It will damage the hinges. Prop the top up with supporting brace or use shipping box as shown. Align the 3 hoes in the stove with the holes in the grille and secure in place. 1. Remove grille from packaging. 2. Lift top up and place shipping box in vertically. 3. Place 1 flap of the box lid into opening for stability. 4. Align the 3 holes in the stove with the holes in the grille. 5. Use a Phillips screwdriver to secure in place. 6. Remove shipping box and lower top. Install Logo 1. Remove logo from packaging. 2. The logo has 2 studs on the back. 3. Install the logo on the lower left side of the center panel by pressing the 2 studs into the pre-drilled holes. See Figure 21.4. Do not open top all the way back so the weight of the top is supported by the hinges. It will damage the hinges. It will be necessary to prop the top up with a supporting brace. You can use the shipping box as shown in Figure 1. CAUTION Figure 21.3 H. Installing Logo Figure 21.4

December 16, 2011

R CB 1200 Pellet Stove 1. A 12 volt AC thermostat is required to operate this pellet appliance. You may use the included wall mount thermo- stat or purchase an optional programmable thermostat or remote control. It is equipped with an adjustable heat anticipator. The current rating is .05 amps. The anticipator needs to be adjusted to the lowest setting available. 2. When mounting a thermostat on a wall, be sure to follow your thermostat installation instructions carefully. NOTE: Thermostat must be mounted level for accurate readings. The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air. NOTE: If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home. 3. There is a 4 screw terminal block located on the back lower left corner of the stove directly above the power cord inlet. The center 2 screws are for the thermostat wires. J. Thermostat Installation Figure 22.1 Shock hazard. • Do NOT remove grounding prong from plug. • Plug directly into properly grounded 3 prong receptacle. • Route cord away from appliance. • Do NOT route cord under or in front of appli- ance. CAUTION Power Outlet Terminal Block. Center 2 screws for Thermostat Wires I. Door Installation To install door: 1. Carefully remove door from packaging. 2. Line up hinges with hinge pins on appliance body, and slide door down until it sits securely on pins. Figure 22.1. 3. If door is plated, be sure to clean all plated surfaces and glass with a glass cleaner to ensure all oils are removed before your first burn. 4. Remove all labels from glass before burning appliance. To adjust latches: 1. Close door securely. 2. Place rod in slot on the bracket on the door and close latch. 3. Latch must close tightly enough to ensure an airtight seal between the door and the body of the appliance. To increase tension on the latch, turn the rod clockwise a few turns, then attempt to close the latch, until it is snug. Do not overtighten; you should be able to close the latch with your hand. Figure 22.2. 4. After adjusting the latch, place a Phillips head screw driver in the end of the rod, and tighten the nut with a wrench. This will maintain the correct tension on the rod and latch. Hinge Hinge Pin Rod and nut Rod and nut Figure 22.2 Figure 22.3

December 16, 2011

7014-179D Page 23 CB 1200 Pellet Stove 8 Operating Instructions A. Fuel Size And Material 1. Wood Pellets Fuel pellets are made from sawdust or wood by-products. If the source material is hardwood, they can have a higher mineral content, creating more ash. Fuels containing bark will also have higher ash content. Minerals and other noncombustible materials such as sand will turn into a hard, glass-like substance called a clinker when heated to the extreme temperatures our firepot reaches. This is what forms clinkers in the bottom of the firepot. Trees from different areas will vary in mineral content. That is why some fuels produce more clinkers than others. Pellets are manufactured in either 1/4 inch or 5/16 inch (6-8mm) diameter and should be no more than 1-1/2 inches (38mm) in length. Pellet lengths may even vary by lot from the same manufacturer which is why the feed rate may need to be adjusted occasionally. If you burn pellets longer than 1-1/2 inches (38mm) you may have an inconsistent fuel feed rate and/or missed ignitions. Pellet fuel quality can greatly fluctuate. We recommend using premium grade fuel with ash content less than 1%. Even in some fuel labeled “premium” ash content can vary from bag to bag and possibly exceed 1%. High ash fuel, or lack of maintenance, can cause the firepot to fill up and thus create a potential for smoking, sooting and possible hopper fires. Always burn dry fuel. Burning fuel with high moisture content takes heat from the fuel and tends to cool the appliance, robbing heat from your home. Damp pellet fuel can clog the feed system. We recommend that you buy fuel in multi-ton lots whenever possible. Buying large quantities of fuel at once will greatly reduce the number of times the feed adjustments will need to be made. However, we do recommend trying various brands before purchasing multi-ton lots to ensure your satisfaction. 2. Shelled Field Corn Extensive factory and field testing has demonstrated shelled field corn to be an efficient and very economical fuel. We recommend the use of a 50-50 blend of corn and wood pellets. The only change in operation is that the feed rate may require a slight adjustment. The BTU output of the appliance varies slightly compared to pellets, depending on the quality of the corn used. In cases where it is acceptable for the appliance to run full time, 100% corn will work after the fire has been started using wood pellets. B. General Operating Information 1. Thermostat Calls For Heat The appliance is like most modern furnaces; when the thermostat calls for heat, your appliance will automatically light and deliver heat. When the room is up to temperature and the thermostat is satisfied, the red call light will go off and the appliance will shut down. 2. Heat Output Controls This appliance is equipped with a heat output control switch that has three settings or burn rates; low, medium and high. The appliance will turn on and off as the thermostat demands. When the thermostat calls for heat, the appliance will start up on the high setting for the first 4 minutes and 15 seconds, then automatically switch to the burn rate for which it is set. If the appliance is set at one of the lower settings, it will run quieter but take longer to heat up an area than if it were set at a higher burn rate. Regardless of the burn rate, when the area is warm enough to satisfy the thermostat, the appliance will shut off. 3. Fan Speed Switch This switch will adjust the speed of the room distribution air fan or convection blower on all three settings. This means you have six different blower speeds available as there is a high and low on each setting. Heat Output Fan Speed Reset Button Call Light HIGH HIGH MED LOW LOW Figure 23.1 Fire Risk. Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance. WARNING • Do NOT store flammable materials in the appliance’s vicinity. • DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. • DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. • Keep all such liquids well away from the heater while it is in use. • Combustible materials may ignite. Fire Risk. WARNING • High ash fuels, or lack of maintenance, can cause the firepot to overfill. Follow proper shutdown procedure if ash buildup exceeds half way point in firepot. • Failure to do so could result in smoking, sooting and possible hopper fires.

December 16, 2011

R CB 1200 Pellet Stove E. Fire Characteristics A properly adjusted fire with the heat output control switch set on “high” has a short active flame pattern that extends out of the firepot approximately 4 to 6 inches (102 to 152mm). If the fire has tall flames with black tails and seems somewhat lazy, the feed rate will need to be reduced. This is done by sliding the fuel adjustment control rod down, which will reduce the feed. If the fire is not 4 to 6 inches (102 to 152mm) tall, slide the fuel adjustment control rod up to increase the feed. A medium and low setting will give a shorter flame. The flame will rise and fall somewhat. This is normal. Figure 24.1 C. Before Your First Fire 1. First, make sure your appliance has been properly installed and that all safety requirements have been met. Pay particular attention to the fire protection, venting and thermostat installation instructions. 2. Double check that the ash drawer and firebox are empty! 3. Check the position of the thermocouple, located above the firepot, and make sure that it protrudes approximately 3/4 inch (19mm) into the firepot. 4. Close the front door. NOTICE: The tip of the thermocouple must be in contact with the inside end of the thermocouple cover or missed ignitions can occur. The feed adjustment control rod is factory set, and should be adequate for most fuels. The set screw is located at the bottom of the hopper and set loose at the factory so the fuel adjustment control rod will slide up and down by only loosening the thumb screw at the top. See Figure 24.1. Do not re-tighten bottom set screw. However, if the flame height is too high or too low, you will need to adjust the feed rate. Wait until the appliance has been burning for 15 minutes before making your adjustments and allow 15 minutes for feed adjustment to take effect. 1. Loosen the thumb screw. Figure 24.1 2. Adjust the fuel adjustment control rod towards the "+" symbol to increase the feed rate and flame height or towards the "-" symbol, to decrease the feed rate and flame height. 3. Re-tighten the thumb screw. F. Feed Rate Adjustment Instructions D. Starting Your First Fire 1. A thermostat is required for proper operation of this appliance, except for corn. At this time, fill the hopper with pellets, set the thermostat to its lowest setting. Plug the power cord into nearby outlet. 2. The exhaust blower will stay on for approximately 10 minutes even though the thermostat is not calling for heat. This is normal. 3. Locate the heat output control switch mounted on the upper right corner of the right side panel. Switch it to the high setting by pushing the top of the switch in, then adjust the thermostat to its highest setting. The red call light located on the upper right corner of the right side panel will be on. This indicates the thermostat is calling for heat. 4. The fuel feed system and the igniter should now be on. 5. For your first fire it will be necessary to press the reset button every two minutes until pellets start to drop into the firepot, then press button 1 more time. This will fill the feed system and allow the appliance to begin dropping pellets. The appliance will continue to run as long as the thermostat is calling for heat. 6. Once the appliance has ignited, let the it burn for approximately 15 minutes, then set the thermostat to the desired room temperature. Adjust the heat output control switch to the desired setting. Fuel Adjustment Rod Thumb Screw Set Screw

December 16, 2011

7014-179D Page 25 CB 1200 Pellet Stove G. Ignition Cycles 1. During each ignition cycle, it is normal to see some smoke in the firebox. The smoke will stop once the fire starts. 2. The convection blower will automatically turn on after your appliance has reached the set temperature on the “high” setting. This blower transfers heat from your appliance into the room, and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down. 3. Occasionally the appliance may run out of fuel and shut itself down. When this happens, the red call light will be on. To restart it, fill the hopper and press the reset button. (See Figure 23.1, page 23). When you press the reset button the red call light will go out. Release the button and the light will come back on. You should see a fire shortly. If not, follow the instructions on page 24, of “Starting Your First Fire”. H. Frequently Asked Questions Odors and vapors released during initial operation. • Curing of high temperature paint. • Open windows for air circulation. Odors may be irritating to sensitive individuals. CAUTION WARNING Fire Risk Do NOT operate appliance: • With appliance door open. • Firepot floor open. • Cleaning slide plates open. Do NOT store fuel: • Closer than required clearances to com- bustibles to appliance • Within space required for loading or ash removal. ISSUES SOLUTIONS 1. Metallic noise. 1. Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound pro- duced by a furnace or heating duct. This noise does not affect the operation or longevity of your insert. 2. Ash buildup on glass. 2. This is normal. Clean the glass. 3. Glass has turned dirty. 3. Excessive build up of ash. The lower burn settings will produce more ash, the higher burn settings produce less. The more it burns on low the more frequent clean- ing of the glass is required. 4. Fire has tall flames with black tails and is lazy. 4. The feed rate needs to be reduced or the firepot needs cleaning. Heat exchanger of exhaust blower needs cleaning. 5. Smokey start-up or puffs of smoke from the airwash. 5. Either the firepot is dirty or there is too much fuel at start-up and not enough air. Close down feed rate 1/4 inch at a time until this no longer happens. 6. Large flame at start-up. 6. This is normal. Flame will settle down once the fire is established. Back side of Firepot Firepot floor left open Figure 24.1 - DO NOT LEAVE FIREPOT FLOOR OPEN

December 16, 2011

R CB 1200 Pellet Stove 9 Troubleshooting With proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Symptom Possible Cause Corrective Action Plug in appliance - No response. No current to outlet. 7 amp fuse defective. #3 snap disc tripped or defective. Control box defective. Check circuit breaker at service panel. Replace fuse. Reset or replace snap disc. Replace control box. Call light on. No fire. No fuel in firepot. Out of fuel. #2 snap disc may be defective. Vacuum switch not closing, no vacuum. Control box defective. Check hopper. Fill with fuel. Replace snap disc. Check exhaust blower is plugged in and operating. Check vacuum switch is plugged in. Check vacuum hose is in good condition, clear and connected at both ends. Check thermocouple is in good condition and plugged in properly. Make sure venting system is clean. Make sure front door is closed. Replace control box. Call light on. No fire. Partially burned fuel in firepot. Firepot clean-out plate not closed. Firepot is dirty (missed ignition). Check that firepot clean-out plate is fully closed. Clean firepot. Make sure there is no clinker in the firepot. Clinkers may have to be broken up with firepot scraper tool or other means. Call light on. No fire. Unburned pellets in firepot. Firepot clean-out plate not closed. Firepot is dirty. Ignition hole blocked. Igniter not working. Control box defective. Check that firepot clean-out plate is fully closed. Clean firepot. Make sure there is not a clinker in the firepot. Clinkers may have to be pushed out of firepot with firepot scraper tool or other means. Scrape with solid piece of wire. Remove ash drawer to see if igniter is glowing red on start-up. Check igniter wires for good connection. Replace igniter using 1/4 inch male /female spade connectors. Replace control box. Slow or smoky start-up. Firepot clean-out plate not closed. Firepot is dirty. Excessive amount of fuel at start-up. Check that firepot clean-out is fully closed. Clean firepot. Make sure there is not a clinker in the firepot. Clinkers may have to pushed out of firepot with firepot scraper tool or other means. Reduce feed rate using feed rate adjust- ment control rod located inside hopper.

December 16, 2011

7014-179D Page 27 CB 1200 Pellet Stove Symptom Possible Cause Corrective Action Slow or smoky start-up (Cont’d) Dirty exhaust and/or venting system. Check for ash build up in unit, includ- ing behind rear panels, firebox, heat exchanger, exhaust blower and venting. Feed system fails to start. Out of fuel. #2 snap disc may be defective. Vacuum switch not closing. No vacuum. Feed system jammed or blocked. Feed spring not turning with feed motor. Feed motor defective or not plugged in. Check hopper, fill with fuel. Replace snap disc. Firebox door must be closed securely. Check exhaust blower is plugged in and operating. Check vacuum switch is plugged in. Check vacuum hose is in good condition, clear and connected at both ends. Check thermocouple is in good condition and plugged in properly. Make sure venting system is clean. NOTE: High winds blowing into the vent- ing system can pressurize the firebox causing loss of vacuum. Empty hopper of fuel. Use a wet/dry vacuum cleaner to remove remaining fuel, from hopper, including feed tube. Check feed chute for obstructions. Loosen 2 screws and jiggle feed assembly. Check that set screw is tight on feed spring shaft at end of feed motor. Check connections on feed motor, replace if defective. No call light. Unit does not begin start sequence. Thermostat not set to a high enough tempera- ture. Snap Disc #3 tripped. No power. Fuse blown. Connections at thermostat and/or appliance not making proper contact. Defective thermostat or thermostat wiring. Control box defective. Adjust thermostat above room tempera- ture. Reset snap disc. Connect to power. Replace fuse. Check connections at thermostat and appliance. Replace thermostat or wiring. NOTE: To test thermostat and wiring, use a jumper wire at the thermostat block on the unit to by-pass thermostat and wiring. Replace control box. Unit fails to shut off. Call light on. Turn thermostat off. If call light does not go out, disconnect thermostat wires from unit. If call light does go out, thermostat or wires are defective.

December 16, 2011

R CB 1200 Pellet Stove Symptoms Possible Cause Corrective Action Convection blower fails to start. #1 snap disc defective. Blower not plugged in. Blower is defective. Control box is defective. Replace snap disc. Check that blower is plugged into wire har- ness. Replace blower. Replace control box. Exhaust blower fails to start or does not shut off. Blower not plugged in. Blower is clogged with ash. Blower is defective. Control box is defective. Check that blower is plugged into wire har- ness. Clean exhaust system. Replace blower. Replace control box. Large, lazy flame, orange color. Black ash on glass. Dirty appliance. Poor fuel quality, high ash content. Firepot clean-out plate not completely closed. Excessive amount of fuel. Clean unit, including firepot, heat exchang- ers and venting system. Remove stainless steel baffle from firebox to clean ash from on top of baffle. Clean behind rear brick panels. Change fuel brand to premium. Check that firepot clean-out plate is fully closed. Reduce feed rate using feed rate adjustment control rod located inside hopper. Nuisance shutdowns. Low flame. Sawdust buildup in hopper. Feed motor is reversing. Defective thermocouple. Defective control box. Firepot more than 1/2 full. Increase feed by opening feed rate adjust- ment control rod located inside hopper. Clean hopper, see page 31. Check for good connections between feed motor and wire harness. Replace thermocouple. Replace control box. See page 33 for detailed instructions for “High Ash Fuel Content Management” Appliance calls for heat. Call light illuminates. Exhaust blower starts. No feed or igniter. Thermocouple is defective or not properly plugged in. Defective control box Check connections on thermocouple or replace if defective. A flashing yellow light on the control box indicates a problem with the thermocouple. Replace control box.

December 16, 2011

7014-179D Page 29 CB 1200 Pellet Stove 10 Maintaining & Servicing Your Appliance C. General Maintenance 1. Types of Fuel Depending on the type of fuel you are burning will dictate how often you have to clean your firepot. If the fuel you are burning has a high dirt or ash content or you are burning shelled field corn, it may be necessary to clean the firepot more than once a day. Dirty fuel will cause clinkers to form in the firepot. A clinker is formed when dirt, ash or a non-burnable substance is heated to 2000°F (1093°C) and becomes glass-like. See “D” page 33 in this section for more details on fuels with high ash content. Clinker Figure 29.1 - Clinker Shock and Smoke Hazard • Turn down thermostat, let appliance completely cool and exhaust blower must be off. Now you can unplug appliance before servicing. • Smoke spillage into room can occur if appliance is not cool before unplugging. • Risk of shock if appliance not unplugged before servicing appliance. CAUTION A. Proper Shutdown Procedure B. Quick Reference Maintenance Chart Follow the detailed instructions found in this section for each step listed as referenced in the chart below. Cleaning or Inspection Frequency Daily Weekly Monthly Yearly Ash Pan Every 5 bags of fuel OR X Ash Removal from Firebox More frequently depending on the fuel type or ash build-up OR X Beneath Heat Exchanger Every 1 ton of fuel OR X Blower, Combustion (Exhaust) More frequently depending on the fuel type OR X Blower, Convection More frequently depending on operating environment OR X Door Latch Inspection Prior to heating season OR X Exhaust Path More frequently depending on ash build-up OR X Firebox - Prepare for Non-Burn Season At end of heating season OR X Firepot - Burning pellets - hardwood Every 3 bags OR X Firepot - Burning pellets - softwood Every 5 bags OR X Firepot - Burning Corn Every 1 bag OR X Glass When clear view of firepot becomes obscure OR X Heat Exchanger & Drop Tube Every 1 ton of fuel OR X Hopper Every 1 ton of fuel or when changing fuel types OR X Top Vent Adapter More frequently depending on the fuel type or ash build-up OR X Venting System More frequently depending on the fuel type OR X NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of ash at the recommended interval or you see soot coming from the vent. Not properly cleaning your appliance on a regular basis will void your warranty.

December 16, 2011

R CB 1200 Pellet Stove 5. Disposal of Ashes • Frequency: As needed • By: Homeowner Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled. 6. Cleaning Heat Exchanger Chambers & Drop Tube • Frequency: Weekly or every 1 ton of fuel • By: Homeowner The amount of ash buildup in the firepot will be a good guide to determine how often you should clean the heat exchangers. a. Allow the appliance to completely cool down before pulling the cleaning rods. Turn the thermostat on and then immediately off to start the exhaust blower on its cycle time. It will pull fly ash out the exhaust instead of into the room. b. To access the cleaning rods lift the hopper lid. Both black bent handle pull rods are located close to the face of the appliance to the left and right side. c. To clean, pull the rods straight out until it stops, approximately 20 inches (508mm). Slide the rods OUT and IN a couple of times. WARNING Heat exchanger cleaning rods may be warm to the touch. For safety purposes wear gloves. Do not pull heat exchanger cleaning rods while appliance is operating. Push cleaning rods IN when done, DO NOT leave cleaning rods OUT. Injury can occur. 2. Cleaning Firepot with Cleaning Rod & Firepot Scraper • Frequency: Daily or more often as needed • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. If you are just cleaning the firepot, there is no need to unplug the appliance. b. Pull firepot cleaning rod OUT and IN a couple of times to help shake debris loose. If rod is hard to pull, it may be necessary to use your firepot clean-out tool to chip away material that has built up on the bottom plate of the firepot and to push out any clinkers. Larger clinkers may have to be removed from the top of the firepot. Corn clinkers can be especially difficult to break up. c. The firepot floor plate must be fully closed when finished. See Figure 28.1 on page 28. 4. Cleaning Ash Pan • Frequency: Weekly or every 5 bags of fuel • By: Homeowner Locate the ash pan underneath the firepot and using a slight pull up and out remove the ash pan. Empty into a non-combustible container and re-install ash pan. See Disposal of Ashes. 3. Ash Removal from Firebox • Frequency: Weekly or more frequently depending on ash build-up. • By: Homeowner a. Allow the appliance to completely cool down. There must not be any hot ashes in the firebox during cleaning. Turn the thermostat on and then immediately off to start the exhaust blower on its cycle time. It will pull fly ash out the exhaust instead of into the room. b. Frequent cleaning of the ash in the firebox will help slow down the build-up of ash in the exhaust blower and vent system. c. Open door. Remove ash with an ash vacuum or whisk broom and small dust pan. d. This ash is deposited in the same ash pan as the firepot debris. The ash pan should be emptied every time you clean the firebox. Remember to place the ash and debris into a metal or non-combustible container. See Disposal of Ashes. WARNING • NEVER pull firepot cleaning rods or cleaning slide plates when appliance is operating. Hot pellets may fall into ashpan and may start a fire or have mis-starts due to lack of vacuum. Fire Risk. Disposal of Ashes WARNING • Ashes should be placed in metal container with tight fitting lid. • Ashes should be retained in closed container until all cinders have thoroughly cooled.

December 16, 2011

7014-179D Page 31 CB 1200 Pellet Stove 7. Cleaning Beneath Heat Exchanger • Frequency: Monthly or after burning 1 ton of fuel • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off . b. A more thorough cleaning is needed to remove the excess ash that is left behind from the use of the cleaning rods for the heat exchanger tubes. c. The ash will be resting on the back of the baffles. This will require removing the baffles. Please refer to page 33 for instructions on removing the baffles. 9. Cleaning the Glass • Frequency: When clear view of the firepot becomes obscure. • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. b. Use a damp paper towel or any nonabrasive glass cleaner. Wipe off with dry towel. NOTE: There are heavy duty vacuum cleaners specifically designed for solid fuel appliance cleaning. 8. Cleaning Exhaust Path • Frequency: Yearly or more frequently depending on ash build-up. • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off b. Remove access door on the right of the appliance (4 screws). c. Use a small vacuum hose attachment to clean area. d. Re-install and close trap door. Handle glass assembly with care. When cleaning glass: • Avoid striking, scratching or slamming glass. CAUTION • Do NOT clean glass when it is hot. • Do NOT use abrasive cleaners. • Use a hard water deposit glass cleaner on white film. • Refer to maintenance instructions. 13. Cleaning Exhaust Blower - Requires No Lubrication • Frequency: Yearly or as needed • By: Quality Service Technician/Homeowner • Task: Contact your local dealer. 14. Cleaning Convection Blower - Requires No Lubrication • Frequency: Yearly or as needed • By: Qualified Service Technician • Task: Contact your local dealer. 12. Cleaning the Hopper • Frequency: Monthly or after burning 1 ton of fuel • By: Homeowner After burning approximately 1 ton of fuel or changing fuels you will need to clean the hopper to prevent saw- dust build-up. A combination of sawdust and pellets on the auger reduces the amount of fuel supply to the firepot. This can result in nuisance shutdowns and mis-starts. a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. b Empty the hopper of any remaining pellets. c. Vacuum the hopper and feed tube. 10. Door Latch Inspection • Frequency: Prior to heating season • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off b. To adjust, open the latch and pivot the holding rod out. Loosen the jam nut on the rod. c. With a Phillips head screw driver, turn the rod clockwise to tighten. The latch handle should snap securely in place when adjusted properly. d. After adjusting the latch, be sure to tighten the jam nut on the rod to hold the adjustment. 11. Door Gasket Inspection • Frequency: Prior to heating season • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off b. To inspect the door rope (gasket), open the door and see that the door rope extends approximately 1/8 inch (3mm) to 3/16 inch (9.5mm) from the door rope chan- nel. c. It should show signs of compaction all the way around the door where the rope contacts the face of the appli- ance. Confirm there are no air leaks.

December 16, 2011

R CB 1200 Pellet Stove 15. Soot and Fly Ash: Formation & Need for Removal in Exhaust Venting System. • Frequency: Yearly or more frequently depending on ash build-up. • By: Qualified Service Technician/Homeowner Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases. At start-up if there is incomplete combustion, or if there is a shutdown or incorrect operation of the appliance it will lead to some soot formation. This will collect in the exhaust vent- ing system. The venting system may need to be cleaned at least once a year or more often depending upon the quality of your fuel or if there is a lot of horizontal pipe sections. Ash will build up more quickly in the horizontal sections. 17. Preparing Firebox for Non-Burn Season • Frequency: Yearly • By: Homeowner a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. b. Remove all ash from the firebox and vacuum thoroughly. c. Paint all exposed steel, including cast-iron. • Use the Touch-Up paint supplied with the appliance; or, • Purchase paint from your local dealer. • Must use a high-temperature paint made specifi- cially for heating appliances. Clean Out Cover Figure 32.1 16. Cleaning the Top Vent Adapter a. The appliance must be in complete shutdown and the exhaust blower should be off. Allow the appli- ance to completely cool down. b. Open the clean-out cover. See Figure 32.1. c. Sweep out any ash build-up. NOTE: There are heavy duty vacuum cleaners specifi- ically designed for solid fuel appliance cleaning. Frequency: Yearly or more frequently depending on ash build-up. • By: Homeowner

December 16, 2011

7014-179D Page 33 CB 1200 Pellet Stove Correct Flame Size, Yellow/White in Color Correct Figure 33.3 Ash Build Up in Firebox Pellets Back Up In Feed Tube Firepot Overfills Tall, Lazy Flame, Orange in Color Incorrect Figure 33.1 Figure 33.2 D. High Ash Fuel Content Maintenance • Frequency: When the ash build-up exceeds more than half way up the firepot. • By: Homeowner 1. Convection Blower Replacement a. Use proper shut down procedures to shut down the appliance and let it completely cool. b. The convection blower is located at the bottom rear of the appliance. If an outside air kit is also installed, depending on your particular installation you may or may not have to remove the outside air flange. If you do, remove the 2 screws using a Phillips head screw- driver. You do not need to remove the flex pipe from the flange. c. Remove the lower rear screen by removing the 4 screws securing the screen to the unit. d. The motor is mounted on a removable bracket. Remove the 2 screws just above the motor and the whole assembly will tilt down and pull out. e. Disconnect the wires from the blower. The wires coming from the wiring harness are white, red and tan and the wires coming from the blower are black, white and red. The white connects to white, the red to red and black to the tan color wire. E. Blower Replacement Figure 33.4 Remove 2 Screws Remove 4 Screws Outside Air Flex Hose Convection Blower Poor quality pellet fuel, or lack of maintenance, can create conditions that make the firepot fill quickly with ashes and clinkers. This condition makes the appliance susceptible to overfill- ing the firepot with pellets which may result in smoking, sooting and possible hopper fires. Figure 33.1 shows an example where the firepot overfills, pellets back up into the feed tube and ash has accumulated in the firebox. An inefficient and non-economical method of burning of fuel caused by poor quality pellet fuel is shown in Figure 33.2. The correct flame size when good quality, premium pellet fuel is burned is shown in Figure 33.3. If the ash buildup exceeds the half way point in the firepot IMMEDIATE ATTENTION AND CLEANING IS REQUIRED. Fire Risk. WARNING • High ash fuels, or lack of maintenance, can cause the firepot to overfill. Follow proper shutdown procedure if ash buildup exceeds half way point in firepot. • Failure to do so could result in smoking, sooting and possible hopper fires.

December 16, 2011

R CB 1200 Pellet Stove 2. Exhaust Blower Replacement G. Igniter Replacement F. Baffle Removal 1. Use proper shut down procedures to shut down the appliance and let it completely cool down and then unplug it and remove the ash drawer. 2. Follow instructions to remove the ash pan found on page 30. Remove the access plate directly above it by removing the 2 screws just below the ash catcher. 3. The wire leads to the igniter are connected to the wire harness with 1/4 inch male / female spade connectors. These wires will pull forward approximately 4 to 5 inches (102mm to 127mm). Disconnect the spade connections and remove the igniter from the chamber. Loosen the thumb screw and slide igniter out. 4. Install new igniter into the chamber and tighten the thumb screw. Re-connect the wires to the 2 leads with the spade connectors. 5. Remove right side panel and pull wire leads back toward the rear of the appliance to take-up the 4 to 5 inches (102mm to 107mm) previously pulled out. This will keep the wires out of the way of the ash drawer. Double check that the igniter wires are clear of any movement, i.e. ash drawer, firepot cleaning rod, etc. 6. Re-install the ash drawer and side panel and re-connect the power. 1. Use proper shut down procedures to shut down the appliance and let it completely cool down. 2. Open right side panel and then open the door. 3. The 2 baffles are located at the top inside of firebox. 4. Place your hand on the baffle and slide it up and the bottom edge will fall down and then you can lift the baffle out. Repeat for the other side. Igniter Igniter Bracket Thumb Screw Figure 34.1 Remove existing blower: a. Use proper shut down procedures to shut down the appli- ance and let it completely cool and then unplug it. b. Use an 11/32" wrench or nut driver to loosen and remove the (6) nuts holding motor mount plate to the blower housing on your stove. c. Remove washer from beneath the terminal ring on the grounding wire. d. Pull motor/mounting plate from blower housing. e. Scrape off old gasketing material from blower housing. Install new blower: f. The blower and blower housing is shipped as a unit. It is necessary to separate them at this point if you are using the existing blower housing already installed on the appliance: g. Follow steps 2 and 3 above. Discard or set aside the new blower housing. h. Carefully remove gasketing from new housing and set onto the blower housing. Re-install blower to blower housing: i. Install blower on housing ensuring that wiring exits facing the 8 o’clock position. Place the washer and then the grounding wire on nearest mounting plate stud. j. Use nuts removed in step b to secure blower to hous- ing. k. Re-connect wiring (use jumper wire if necessary). Re- connect power supply.

December 16, 2011

7014-179D Page 35 CB 1200 Pellet Stove H. Glass Replacement • Glass is 5mm thick high temperature heat- resistant ceramic glass. • DO NOT REPLACE with any other material. • Alternate material may shatter and cause injury. WARNING Figure 35.1 Top & Bottom Frame Door Latch Side Frame Center Posts Glass Remove Door Latch First and then Side Frame Door Frame shown with no Glass or Glass Frames Remove 5 nuts from Bottom Frame Figure 35.2 Handle glass with care. • Inspect the gasket to ensure it is undamaged. • Do NOT strike, slam or scratch glass. • Do NOT operate appliance with glass assembly removed. WARNING • Do NOT operate with glass cracked, broken or scratched. • Remove door from appliance and place face down on a protected surface to avoid scratching the door. • Remove all door rope. 1. Replacing Center Glass NOTE: DO NOT LET Air Wash Spacers fall down from top frame when removing and replacing center glass. a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. b. Using a nut driver remove the (5) bottom nuts and remove the bottom glass frame. Figure 35.2. c. Slightly bend up and out of the way the 2 center posts and slide the glass out the bottom. d. Slide new glass in, reposition the 2 center posts and re-install bottom glass frame. e. Re-rope the door. 2. Replacing Side Glass NOTE: When removing the side glass with the door latch, you must remove the door latch first before removing the side frame. Use a pow- ered Phillips head screw driver to remove the 4 screws. a. Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. b. Remove side glass frame. c. Loosen the top and bottom frame and slightly bend up and out of the way. d. Slide glass out the side and slide new glass in. e. Re-install the side glass frame and tighten the top and bottom frames. f. Re-install the door latch, if applicable, and re-rope the door.

December 16, 2011

R CB 1200 Pellet Stove 11 Reference Materials 7. Heat Exchangers The heat exchangers transfer hot air from the exhaust system into convection air. Lift the stove top to access the heat exchangers. There are 2 clean out rods located under the heat exchangers. 8. Heat Output Switch The heat output switch is located on the upper right side panel. The function of the heat ouput switch is to regulate the burn rates; low, medium, and high settings. 9. Hopper Switch The hopper switch is located in the upper right hand corner of the hopper. This switch is designed to shut down the feed motor whenever the hopper lid is opened. 10. Igniter The igniter is mounted on the base of the firepot. Combustion air travels over the red hot igniter creating super heated air that ignites the pellets. 11. Junction Box And Wiring Harness The junction box is located on the right side of the appliance, behind the interior shield. The junction box and wiring harness are replaced as one component. 12. Power Supply The power outlet is located on the back of the appliance, lower right corner. Check the wall receptacle for 120 volt, 60 Hz (standard current). Make sure the outlet is grounded and has the correct polarity. A good surge protector is recommended. 13. Red Call Light The red call light is on the front of the junction box, next to the reset button. The function of the red call light is to indicate that the thermostat is calling for heat. 14. Reset Button The reset button is located on the right side of the apppliance next to the red call light. The function of the button is to momentarily open the thermostat circuit, which restarts the system. 15. Thermocouple The thermocouple is located on top of the firepot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control box indicating the preset temperatures of the green and red lights have been obtained. When describing the location of a component, it is always AS YOU FACE THE FRONT OF THE APPLIANCE. 2. Convection Blower The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room. 3. Combustion (Exhaust) Blower The combustion blower is mounted on the lower left side on rear of appliance. The blower is designed to pull the exhaust from the appliance and push it out through the venting system. 4. Feed System The feed system is located in the hopper under the feed motor cover box on the left side of the appliance and can be removed as an entire assembly. The assembly includes the feed motor, mounting bracket, bearing and feed spring (auger). The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the firepot. 5. Firepot The firepot is made of high quality ductile iron and has a cleaning pull-out rod. The floor of the firepot opens for cleaning when you pull out the rod. Be sure that the floor returns to a completely closed position or your appliance will not operate properly. 6. Fuse The fuse is located on the front of the junction box on the right side of the appliance. The fuse will blow should a short occur and shut off power to the appliance. NOTE: Do NOT open the control box. This will void the warranty. If you need to plug in or remove the control box you must first unplug the appliance. 1. Control Box a. The control box is located under a small cover in the right rear corner of the inside of the hopper. b. There is a light located inside of the control box. The internal light will turn green when the appliance has reached a temperature of 200oF (93°C) in the firepot and will turn red when it reaches 600 oF (315°C). c. There is also an internal blue light located in the upper left corner of the control box. When you plug in the appliance the blue light will automatically start blinking 1 blink every 10 seconds for the first 60 seconds and then will stop. A. Component Function & Location E

December 16, 2011

7014-179D Page 37 CB 1200 Pellet Stove 16. Thermostat The appliance is designed to run on a 12 volt AC thermostat. The heat anticipator should be set on the lowest setting available. 17. Snap Disc #1 (Convection Blower) 145°F Snap disc #1 is located on the right side of the appliance on the top of the heat exchanger box. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap disc #1. 18. Snap Disc #2 (Thermostat Override) 200°F Snap disc #2 is also located on the right side of the appliance between snap disc #1 and convection blower. There are 2 yellow wires connected to it. This snap disc will turn off the feed system, which will turn off the appliance if an overfire condition should occur or if the convection blower should fail to operate. 19. Snap Disc #3 (Back Burn Protector) 250°F Snap disc #3 is mounted on the back of the auger tube in the right side of the appliance just below the feed motor and has a red reset button. To access it remove the feed motor cover box from inside the hopper. If the fire tries to burn back into the feed system or push exhaust up the feed tube, this snap disc will shut the entire system off. This disc must be manually reset. 20. Vacuum Switch The vacuum switch is located on the left side of the appliance behind the inner shield. This switch turns the feed system on when vacuum is present in the firebox. The vacuum switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is dirty or plugged or if the firebox door is open. 21. Wiring Harness See Figure 37.1 below. Figure 37.1 Thermocouple Heat Output Switch Thermostat Block Snap Disc #2 Snap Disc #1 Feed Motor Vacuum Switch Capacitor Convection Blower Blower Speed Exhaust Blower Snap Disc #3 Reset Button Call Light Fuse Yellow Yellow Purple Purple Red Red Orange White Blue Blue Black Black Gray High Temp High Temp Igniter Hopper Switch

December 16, 2011

R CB 1200 Pellet Stove B. Component Locations Heat Output Fan Speed Reset Button Call Light HIGH HIGH MED LOW LOW Power Outlet Terminal Block. Center 2 screws for Thermostat Wires Outside Air Flex Hose Convection Blower Cleaning Rods Heat Exchanger Tubes Figure 38.1 Figure 38.3 Figure 38.4 Figure 38.2

December 16, 2011

7014-179D Page 39 CB 1200 Pellet Stove C. Exploded Views Figure 39.1 Service Parts 12/11 R Classic Bay Freestanding Pellet Stove CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active 1 5 2 3 6 7 12 9 8 4 10 11 13 14 15 16 21 17 18 19 20 22 23 24 25 26 33 35 37 38 39 40 31 29 28 27 30 36 32 34 Part number list on following page.

December 16, 2011

R CB 1200 Pellet Stove Figure 40.1 B. Service Parts & Accessories Service Parts 12/11 R IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Top Assembly with Hopper Lid 812-3940 1.1 Handle, Hopper Lid 200-0110 1.2 Lid, Hopper 410-4901 Bumper, Rubber Pkg of 12 SRV224-0340/12 Y Bushing, Hopper Lid Qty: 2 812-1010 1.3 Top Assembly Top Only SRV410-4980 Magnetic Switch 7000-375 Y 2.1 Baffl e Assembly Left Post 3619669 510-5350 2.2 Baffl e Assembly Right Post 3619669 510-5360 3 Brick Set 811-0601 Brick Retainer Clips Assembly Pkg of 2 SRV510-1020 4 Curtain Mount, Side Left 410-5251 5 Curtain, Side Left 812-3840 6 Curtain, Pedestal Side Right or Left 410-5391 7 Casting, Exhaust Transition 180-0190 8 Blower, Combustion/Exhaust 812-3381 Y 9 Gasket, Exhaust Combustion Blower (between…) ...Motor & Housing 812-4710 Y ...Housing & Stove 240-0812 Y Additional service part numbers appear on following page. CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active 1.1 1.2 1.3 2.1 2.2 #1 Top Assembly #2 Baffl e Assembly

December 16, 2011

7014-179D Page 41 CB 1200 Pellet Stove Service Parts 12/11 R IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 10.1 Rod/Linkage, Ez Clean 812-3850 Bolt, Firepot, 1-1/4” Long Pkgo of 25 225-0120/25 Y Knob, Ash Dump Control Rod 832-3020 Spring, Firepot 200-2050 10.2 Firepot Assembly 812-3351 Y Bushing, Firepot 410-8320 Y Floor, Firepot 414-0290 Y Gasket, Firepot 510-0530 Y 10.3 Thermocouple Cover Qty: 1 812-1322 Y Pkg of 10 812-4920 Y 10.4 Thermocouple 812-0210 Y 10.5 Thermocouple Bracket W/Set Screw 812-3171 Y 10.6 Heating Element 6”, Loop Igniter Qty: 1 812-3811 Y Pkg of 10 812-4560 Y Wing Thumb Screw 8-32 X 1/2 Pkg of 24 7000-223/24 Y 11 Door Assembly Black DR-CB12-MBK-B Gold DR-CB12-GD-B Nickel DR-CB12-NL-B 11.1 Hinge, Female 450-2910 11.2 Glass Assembly, Center - 13-7/8” W x 11” H 510-5400 Y 11.3 Glass Assembly, Side, 1 Pc - 5-1/8” W x 11” H Interchangeable 510-5410 Y 11.4 Glass Retainer Assembly 510-5460 Door Rope, 7/8”, Field Cut to Size 8 Ft. 842-2350 Y Gasket, Glass, Field Cut to Size 10 Ft. 833-0660 Additional service part numbers appear on following page. CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active 10.1 10.2 10.3 10.4 10.5 10.6 11.1 11.4 11.3 11.2 #10 Firepot Assembly and Associated Parts #11 Door Assembly

December 16, 2011

R CB 1200 Pellet Stove Service Parts 12/11 R IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 12 Bracket, Door Latch 410-4912 13 Ashpan 812-4050 Gasket, 7/16” 10 Ft 844-6730 Y 14 Panel, Front Access 410-5161 15 Exhaust Plenum Trap Door 812-4100 16 Exhaust Plenum Cleanout Plate 410-4871 17 Latch, Magnetic - For Side Curtain Air Defl ector 812-3821 Latch, Magnet 229-0631 18 Mount, Side Curtain, Right 410-5261 19 Curtain, Side Right 812-3800 20 Latch, Draw 229-0640 Y 21 Snap Disc, Convection Blower # 1 SRV230-0060 Y 22 Blower Convection 812-3370 Y 23 Snap Disc, 200 Open/40 D, # 2 SRV230-0900 Y 24 Director, Air, Large 410-8250 25 Director, Air, Small 410-8260 26 Grille, Louver Black LVGRL-CB12-BK-B Gold LVGRL-CB12-GD-B Nickel LVGRL-CB12-NL-B Grille, Bar, Bottom 410-8330 27 Extension, Heat Shield Top 410-5322 28 Panel, Feed Motor Access 410-6220 29 Wire Harness, Junction box SRV7000-154 Y Block, Thermostat Term Dv 230-0690 Igniter Extension 7000-218 30 Panel, Rear Access, Bottom 410-5413 31 Defl ector, Air, Right Curtain 410-5105 32 Snap Disc, Manual Reset SRV230-1290 Y 33 Panel, Rear Access, Top 410-4352 34 Vacuum Switch SRV7000-531 Y 35 Control Board 3 Speed SRV7000-205 Y 36 Cover, Control Box 410-6321 37 Feed Adjustment Plate 812-4170 38 Cover, Feed Motor 410-5311 Additional service part numbers appear on following page. CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active

December 16, 2011

7014-179D Page 43 CB 1200 Pellet Stove Service Parts 12/11 R IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 39 Feed Motor Assembly 812-3690 Y Bearing, Feed System, Nylon 410-0552 Y 39.1 Screw, 8-32 X 3/8 PH Pkg of 40 225-0500/40 Y 39.2 Feed Motor 812-4421 Y 39.3 Collar, Set, 7/8 229-0520 39.4 Feed Bearong SRV7000-598 Y 39.5 Mount, Feed Motor 410-7172 39.6 Gasket, Feed Motor 240-0731 Y 39.7 Feed Spring Assembly SRV7027-024 Y 39.8 Screw, 5/16-18 X 1/4 Pkg of 25 225-0550/25 Y 40 Defl ector, Air, Left Curtain 410-4992 Additional service part numbers appear on following page. CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active 39.1 39.2 39.3 39.4 39.5 39.6 39.7 39.8 #39 Feed Motor Assembly

December 16, 2011

R CB 1200 Pellet Stove Service Parts 12/11 R IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Bracket, Snap Disc Mounting 410-2521 Call Light, Fluorescent - New Style Junction Box SRV7000-122 Component Pack (Includes Firepot Cleanout Tool, Touch- Up Paint, Power Cord, Wire Harness For Thermostat, Owners Manual, Warranty Card, Consumers View Card & “How To” Dvd) 812-3630 Cleanout Tool 414-1140 Y Dvd Original Energy Stove 7000-440 Harness, Thermostat Wire 230-0810 Paint Touch-Up, 4 oz 812-0910 Power Cord 812-1180 Y Fuse, Amp .7, Junction Box Pkg of 10 812-0380/10 Y Fuse, Amp .8, Control Box Pkg of 10 812-3780/10 Y Hinge Plate 812-4030 Hinge, Door, Male 450-2810 Hose, Vacuum, 5/32 Id - Field Cut to Size Qty. 3 Ft. Req. SRV240-0450 Y Igniter Wire (5Ft) & (4) Ceramic Nuts 812-4520 Y Rocker Switch, 3-Position Heat Output 812-3500 Y Switch, Rocker (Fan Speed) 812-3910 Thermocouple Grounding Kit 812-4980 Additional service part numbers appear on following page. CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active

December 16, 2011

7014-179D Page 45 CB 1200 Pellet Stove Service Parts 12/11 R CB1200M-MBK Beginning Manufacturing Date: April 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER ACCESSORIES Collar, Offset, Top Vent 812-3570 Damper, 3 Inch - Tall Vertical Installs Only PEL-DAMP3 Y Damper, 4 Inch - Tall Vertical Installs Only PEL-DAMP4 Log Set 811-0592 Log, Front 7027-219 Log, Rear Left 7027-221 Log, Rear Right 7027-220 Outside Air Kit, Floor 811-0570 Outside Air Kit, Rear 811-0872 Channel, Air Intake 413-7040 Cover, Outside Air Kit, Floor 411-1071 Hose, Alum Flex, 2 Inch x 3 Ft Qty. 3 Ft. Req. 200-0860 Outside Air Cap Assembly 7001-044 Outside Air Collar Assembly 7001-045 Trim Plate, Outside Air Kit 412-7100 Smart-Batt Il 841-0970 Smart-Stat Il 841-0960 Thermostat, Mechanical 812-3760 Y Thermostat, Programmable 811-0520 Top Vent Adapter TPVNT-1 Vent Adapter, 90, Cleanout 811-0610 Vent Adapter, Rear 811-0620 FASTENERS Avk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tool RIVNUT-REPAIR Y Bolt, Shoulder, 5/16 X 1/4-20 Pkg of 20 223-0170/20 Y Ceramic Nuts, (Igniter) Pkg of 12 812-0730/12 Y Nut, Keps Lock, 8-32 Pkg of 40 226-0060/40 Y Nut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24 Y Nut, Wing, 8-32 Pkg of 24 226-0160/24 Y Screw, Pan Head Philips 10-32 X 3/8 Pkg of 40 21799A/40 Y Screw, Pan Head Philips 8-32 X 3/4 Pkg of 24 229-1100/24 Y Screw, Sheet Metal #8 X 1/2 S-Grip Pkg of 40 12460/40 Y Washer, 1/4 Sae Pkg of 24 28758/24 Y Washer, Sae, 3/8 Pkg of 3 ea. 832-0990 Y

Hearth & Home Technologies

1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES www.quadrafire.com 7014-179D December 16, 2011 Page 48 CONTACT INFORMATION: This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer visit our website at www.quadrafire.com Date purchased/installed: Serial Number: Location on appliance: Dealership purchased from: Dealer phone: Notes: We recommend that you record the following pertinent information for your CB1200 PELLET STOVE NOTICE DO NOT DISCARD THIS MANUAL • Important operating and maintenance instruc- tions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instruc- tions for safe installa- tion and operation. DO NOT DISCARD